You are on page 1of 73

P-2

P-3

PAINTING SPECIFICATION
P-4
P-5

SUPPLY SCOPE & WEIGHT LIST


P-6
P-7
P-8
P-9

FAN SPECIFICATION
P-10
P-11
P-12
P-13

FAN DRAWINGS & SPARE PART LIST


P-14
P-15
P-16
P-17
P-18
P-19
P-20
P-21
P-22
P-23
P-24
P-25
P-26
P-27
P-28
P-29
P-30
P-31
P-32
P-33
P-34
P-35
P-36
P-37
P-38
P-39
P-40
TOLERANCES DIMENSION = | ANGLES = | SURFACE = 25S
MATERIAL - PROJECT - REV
TREATMENT - SUBJECT Part 1.0
FINISH - TITLE SCALE
COMMENT -
CQA2+CA50~100
WEIGHT - (kg)

DRAWN 2011-09-16 DWG NO. SIZE

DESIGN 2011-09-16 A4
CHECKED 2011-09-16 CATEGORY PART NO. SEET
MGR APPR - 1/1
P-41
P-42
P-43
P-44
P-45
P-46

PERFORMANCE CURVE & MOTOR DIMENSION


P-47

Performance Curve
Version : 4.4.0.2

Date 2020-05-07 Sys. No. S101~104


Yard HHI Use ENGINE ROOM VENT FAN
Hull No. 3137/3138 Name CSK

Fan Type AKA-1600/710 Fan Speed 1180 rpm


P-48

Performance Curve
Version : 4.4.0.2

Date 2020-05-07 Sys. No. E105/106


Yard HHI Use PURIFIER ROOM EXH.
Hull No. 3137/3138 Name CSK

Fan Type AKA-710/350 Fan Speed 1765 rpm


P-49

Performance Curve
Version : 4.4.0.2

Date 2020-06-17 Sys. No. E107


Yard HHI Use WELDING SPACE EXH.
Hull No. 3137/3138 Name CSK

Fan Type AWA-350/150 Fan Speed 3550 rpm


P-50

ESTIMATED PERFORMANCE CURVE


TAE-IL BLOWER
OF FAN/BLOWER

420

390

360

330

300

270

240 Static Pressure

210

180
Efficiency
5 150

Shaft Power

0 1 2 3 4 5 6 7 8
P-51

ESTIMATED PERFORMANCE CURVE


OF FAN/BLOWER
E112~E115 20.09.01
G/E GVU ROOM EXH. FAN HAK

TTF-2.5-S1 HHI

30

40 1.5 440

20 4 3
1.205 1720 60

1720

0.46
45

84

78

72

66

60

54

Total Pressure
48
Static Pressure

42

4 Efficiency

Shaft Power
0 5 10 15 20 25 30 35 40
P-52

ESTIMATED PERFORMANCE CURVE


TAE-IL BLOWER
OF FAN/BLOWER
E116~E117 H3137/3138 2020-05-06
HAK J.W.YU
TTF-3.0-S1 HHI S.M.SON
80
40 1.5 440
45 4 3
1.11 1720 60
1720 @
1.3
55

112

104

96

88

80

72

64

56
Total Pressure
Static Pressure

5 Efficiency

1
Shaft Power

0 12 24 36 48 60 72 84 96
P-53

ENGINE ROOM SUP.FAN


P-54

PURIFIER ROOM EXH.FAN


P-55

WELDING SPACE EXH.FAN


P-56
P-57
P-58

TEST REPORT
P-59

TEST REPORT FOR AXIAL FLOW FAN


축류 송풍기 시험 성적서

Customer : HHI Hull No. : 3137

FAN
Type AKA-1600/710 Sys. No. S101
Ps 55 mmAq Q'ty 1 set
Fan served No.1 ENGINE ROOM VENTILATION FAN (NON-REVERSIBLE)

MOTOR
Maker HYUNDAI Type 250S-6
Output 45.00 ㎾ Voltage 3φ x 440V, 60㎐
Ser. No. 20D178-J04001 IP 56

* TEST RESULT
SPEC. ACT' SPEC. ACT'

Velocity (m/s) 17.4 18.1 D.F.T(in) 150 ㎛ 175~324 ㎛

Air volume (㎥/min) 2,100 2,184 D.F.T(out) 310 ㎛ 316~653 ㎛

Rating Current (A) 75.6 66.2 AIR GAP 1~13 ㎜ 5.4-8.8 ㎜

R.P.M. 1,180 1,195 VIBRATION Below 2.8 ㎜/s 1.1 ㎜/s

S.P.L dB(A) 98.0 97.3


Megger (MΩ) 10 ↑ 2,000
Remarks

*Test Duct Dia. : 1600 mm


*Air volume = Velocity × Duct area

Remarks : We certify fan is/are of same rating of that shown on Type Test Report
and running tested in accordance with KS/QTP standards.
Tolerance of S.P.L : +4 dB(A)

Inspection Date : 2021-01-20 Tested By : S. J. Kim


PAINT BRAND & COLOR SPEC. ----------------------
IN 1-EP 1760 GREY 1135 (150) Approved By : K. I. Han
1-EP 1760 GREY 1135 (125) ----------------------
OUT 2-EP 1760 GREY 1135 (125) Witness By :
3-ST 1020 WHITE 1000 (60) ----------------------
BALANCING RESULT
- Reger to the next page

HI AIR KOREA Co., Ltd. QM Dept.


P-60

TEST REPORT FOR AXIAL FLOW FAN


축류 송풍기 시험 성적서

Customer : HHI Hull No. : 3137

FAN
Type AKA-1600/710 Sys. No. S102
Ps 55 mmAq Q'ty 1 set
Fan served No.2 ENGINE ROOM VENTILATION FAN (REVERSIBLE)

MOTOR
Maker HYUNDAI Type 250S-6
Output 45.00 ㎾ Voltage 3φ x 440V, 60㎐
Ser. No. 20D178-J03001 IP 56

* TEST RESULT
SPEC. ACT' SPEC. ACT'

Velocity (m/s) 17.4 18.0 D.F.T(in) 150 ㎛ 170~336 ㎛

Air volume (㎥/min) 2,100 2,171 D.F.T(out) 310 ㎛ 312~674 ㎛

Rating Current (A) 75.6 65.2 AIR GAP 1~13 ㎜ 5.5-8.6 ㎜

R.P.M. 1,180 1,195 VIBRATION Below 2.8 ㎜/s 1.2 ㎜/s

S.P.L dB(A) 98.0 97.5


Megger (MΩ) 10 ↑ 2,000
Remarks

*Test Duct Dia. : 1600 mm


*Air volume = Velocity × Duct area

Remarks : We certify fan is/are of same rating of that shown on Type Test Report
and running tested in accordance with KS/QTP standards.
Tolerance of S.P.L : +4 dB(A)

Inspection Date : 2021-01-20 Tested By : S. J. Kim


PAINT BRAND & COLOR SPEC. ----------------------
IN 1-EP 1760 GREY 1135 (150) Approved By : K. I. Han
1-EP 1760 GREY 1135 (125) ----------------------
OUT 2-EP 1760 GREY 1135 (125) Witness By :
3-ST 1020 WHITE 1000 (60) ----------------------
BALANCING RESULT
- Reger to the next page

HI AIR KOREA Co., Ltd. QM Dept.


P-61

TEST REPORT FOR AXIAL FLOW FAN


축류 송풍기 시험 성적서

Customer : HHI Hull No. : 3137

FAN
Type AKA-1600/710 Sys. No. S103
Ps 55 mmAq Q'ty 1 set
Fan served No.3 ENGINE ROOM VENTILATION FAN (NON-REVERSIBLE)

MOTOR
Maker HYUNDAI Type 250S-6
Output 45.00 ㎾ Voltage 3φ x 440V, 60㎐
Ser. No. 20D178-J02001 IP 56

* TEST RESULT
SPEC. ACT' SPEC. ACT'

Velocity (m/s) 17.4 18.2 D.F.T(in) 150 ㎛ 178~332 ㎛

Air volume (㎥/min) 2,100 2,196 D.F.T(out) 310 ㎛ 314~647 ㎛

Rating Current (A) 75.6 66..6 AIR GAP 1~13 ㎜ 5.2-8.7 ㎜

R.P.M. 1,180 1,194 VIBRATION Below 2.8 ㎜/s 1.2 ㎜/s

S.P.L dB(A) 98.0 97.2


Megger (MΩ) 10 ↑ 2,000
Remarks

*Test Duct Dia. : 1600 mm


*Air volume = Velocity × Duct area

Remarks : We certify fan is/are of same rating of that shown on Type Test Report
and running tested in accordance with KS/QTP standards.
Tolerance of S.P.L : +4 dB(A)

Inspection Date : 2021-01-20 Tested By : S. J. Kim


PAINT BRAND & COLOR SPEC. ----------------------
IN 1-EP 1760 GREY 1135 (150) Approved By : K. I. Han
1-EP 1760 GREY 1135 (125) ----------------------
OUT 2-EP 1760 GREY 1135 (125) Witness By :
3-ST 1020 WHITE 1000 (60) ----------------------
BALANCING RESULT
- Reger to the next page

HI AIR KOREA Co., Ltd. QM Dept.


P-62

TEST REPORT FOR AXIAL FLOW FAN


축류 송풍기 시험 성적서

Customer : HHI Hull No. : 3137

FAN
Type AKA-1600/710 Sys. No. S104
Ps 55 mmAq Q'ty 1 set
Fan served No.4 ENGINE ROOM VENTILATION FAN (REVERSIBLE)

MOTOR
Maker HYUNDAI Type 250S-6
Output 45.00 ㎾ Voltage 3φ x 440V, 60㎐
Ser. No. 20D178-J01001 IP 56

* TEST RESULT
SPEC. ACT' SPEC. ACT'

Velocity (m/s) 17.4 18.1 D.F.T(in) 150 ㎛ 177~340 ㎛

Air volume (㎥/min) 2,100 2,184 D.F.T(out) 310 ㎛ 318~648 ㎛

Rating Current (A) 75.6 66.2 AIR GAP 1~13 ㎜ 5.2-8.6 ㎜

R.P.M. 1,180 1,187 VIBRATION Below 2.8 ㎜/s 1.2 ㎜/s

S.P.L dB(A) 98.0 97.0


Megger (MΩ) 10 ↑ 2,000
Remarks

*Test Duct Dia. : 1600 mm


*Air volume = Velocity × Duct area

Remarks : We certify fan is/are of same rating of that shown on Type Test Report
and running tested in accordance with KS/QTP standards.
Tolerance of S.P.L : +4 dB(A)

Inspection Date : 2021-01-20 Tested By : S. J. Kim


PAINT BRAND & COLOR SPEC. ----------------------
IN 1-EP 1760 GREY 1135 (150) Approved By : K. I. Han
1-EP 1760 GREY 1135 (125) ----------------------
OUT 2-EP 1760 GREY 1135 (125) Witness By :
3-ST 1020 WHITE 1000 (60) ----------------------
BALANCING RESULT
- Reger to the next page

HI AIR KOREA Co., Ltd. QM Dept.


P-63

TEST REPORT FOR AXIAL FLOW FAN


축류 송풍기 시험 성적서

Customer : HHI Hull No. : 3137

FAN
Type AKA-710/350 Sys. No. E105
Ps 50 ㎜Aq Q'ty 1 set
Fan served PURIFIER ROOM EXH. FAN(S)

MOTOR
Maker HHI Type 132M-4
Output 7.5 ㎾ Voltage 3φ x 440V, 60㎐
Ser. No. 20D212-C87001 IP 54

* TEST RESULT
SPEC. ACT' SPEC. ACT'

Velocity (m/s) 15.8 16.3 D.F.T(in) 150 ㎛ 158-313 ㎛

Air volume (㎥/min) 375 387 D.F.T(out) 120 ㎛ 127-272 ㎛

Rating Current (A) 14.1 10.2 AIR GAP 1~13 ㎜ 2.8-5.5 ㎜

R.P.M. 1,760 1,782 VIBRATION Below 2.8 ㎜/s 0.8 ㎜/s

S.P.L dB(A) 87.0 85.8


Megger (MΩ) 10 ↑ 2,000
Voltage (V) 440 435~440
Remarks

*Test Duct Dia. : 710 mm


*Air volume = Velocity × Duct area

Remarks : We certify fan is/are of same rating of that shown on Type Test Report
and running tested in accordance with KS/QTP standards.
Tolerance of S.P.L : +4 dB(A)

Inspection Date : 2021-03-04 Tested By : S. J. Kim


PAINT BRAND & COLOR SPEC. ----------------------
IN 1-EP 1760 GREY 1135 (150) Approved By : K. I. Han
1-EP 1760 GREY 1135 (70) ----------------------
OUT
2-EPOXY MUNSELL NO.7.5BG 7/2 (50) Witness By :
----------------------

HI AIR KOREA Co., Ltd. QM Dept.


P-64

TEST REPORT FOR AXIAL FLOW FAN


축류 송풍기 시험 성적서

Customer : HHI Hull No. : 3137

FAN
Type AKA-710/350 Sys. No. E106
Ps 50 ㎜Aq Q'ty 1 set
Fan served PURIFIER ROOM EXH. FAN(P)

MOTOR
Maker HHI Type 132M-4
Output 7.5 ㎾ Voltage 3φ x 440V, 60㎐
Ser. No. 20D212-C86001 IP 54

* TEST RESULT
SPEC. ACT' SPEC. ACT'

Velocity (m/s) 15.8 16.5 D.F.T(in) 150 ㎛ 162-330 ㎛

Air volume (㎥/min) 375 392 D.F.T(out) 120 ㎛ 133-284 ㎛

Rating Current (A) 14.1 10.6 AIR GAP 1~13 ㎜ 2.5-5.6 ㎜

R.P.M. 1,760 1,784 VIBRATION Below 2.8 ㎜/s 0.8 ㎜/s

S.P.L dB(A) 87.0 86.2


Megger (MΩ) 10 ↑ 2,000
Voltage (V) 440 435~440
Remarks

*Test Duct Dia. : 710 mm


*Air volume = Velocity × Duct area

Remarks : We certify fan is/are of same rating of that shown on Type Test Report
and running tested in accordance with KS/QTP standards.
Tolerance of S.P.L : +4 dB(A)

Inspection Date : 2021-03-04 Tested By : S. J. Kim


PAINT BRAND & COLOR SPEC. ----------------------
IN 1-EP 1760 GREY 1135 (150) Approved By : K. I. Han
1-EP 1760 GREY 1135 (70) ----------------------
OUT
2-EPOXY MUNSELL NO.7.5BG 7/2 (50) Witness By :
----------------------

HI AIR KOREA Co., Ltd. QM Dept.


P-65

TEST REPORT FOR AXIAL FLOW FAN


축류 송풍기 시험 성적서

Customer : HHI Hull No. : 3137

FAN
Type AWA-350/150 Sys. No. E107
Ps 30 ㎜Aq Q'ty 1 set
Fan served WELDING AREA EXH.

MOTOR
Maker HHI Type 80-2
Output 0.75 ㎾ Voltage 3φ x 440V, 60㎐
Ser. No. 20D185-A32001 IP 54

* TEST RESULT
SPEC. ACT'
Velocity (m/s) 4.0 4.3
Air volume (㎥/min) 30 32
Rating Current (A) 1.50 1.2
R.P.M. 3,450 3,485
Megger (MΩ) 10 ↑ 2,000
Voltage (V) 440 435~440
Remarks

*Test Duct Dia. : 400 mm


*Air volume = Velocity × Duct area

Remarks : We certify fan is/are of same rating of that shown on Type Test Report
and running tested in accordance with KS/QTP standards.

Inspection Date : 2021-04-07 Tested By : S. J. Kim


PAINT BRAND & COLOR SPEC. ----------------------
1-EP 1760 GREY 1135 (100) Approved By : K. I. Han
IN / OUT
2-EH 4600 WHITE 1000 (50) ----------------------
Witness By :
----------------------

HI AIR KOREA Co., Ltd. QM Dept.