Professional Documents
Culture Documents
1
Advances in
Seismic Design And Construction
for High-Rise Buildings
In Indonesia
IBC 2011
3 maps for 500-yr EQ and 3 for 2500-yr EQ
a.PGA
b.Spectra at 0.2 sec
c.Spectra at 1.0 sec
ASCE 7-05
ASCE 7-10
2
Mw for Seismic hazard map 2010
Vertical Irregularities
Horizontal Irregularities
Redundancy Factors
3
The Pakubuwono Signature
-
- 50-story 250-M high
RC core wall & outrigger
PAKUBUWONO SIGNATURE
- First building analyzed with
PBSD method in Indonesia
- Structural Engineer: Davy Sukamta & Partners
- Completed in 2014
Floor-to-floor 3.85m
RC Core wall and Outriggers as lateral resisting system
Wall thickness 650 mm
Outrigger Beam 3-story deep
Expected inelastic action at coupling beams, base of
The use of core wall, both ends of outrigger columns
PERFORMANCE-BASED SEISMIC DESIGN
core wall
hinge zones
4
CTBUH 2014 Shangai Conference CTBUH 2014 Shangai Conference
5
Earthquakes Can Be Catastrophic
And Very Expensive
6
Plan of Base Isolators Courtesy: Bridgestone,Japan
HDRB
Outrigger Beam
7
Performance of Seismically Isolated Structure vs Conventional Structure
Base-isolated Structure
Nomor Periode Getar Faktor Partisipasi Mass (%)
Ragam (detik) X-trans Y-trans Rz-rotn
1 4.233 0.00 99.05 0.00
2 4.160 99.20 0.00 0.18
3 3.454 0.18 0.00 99.81
R=2.0 CD=2.0
RC core wall
R=6.0 CD=5.0
Outrigger
Fixed-base Structure
Outrigger Nomor
Periode
Getar Nomor
Periode
Getar Faktor Partisipasi Mass (%)
Column Ragam (detik) Ragam (detik) X-trans Y-trans Rz-rotn
1 1.657 1 1.657 0.00 58.08 0.01
2 1.453 2 1.453 54.97 0.00 0.03
3 1.012 3 1.012 0.01 0.00 65.31
Dynamic Characteristic of
Based-Isolated vs Fixed-Base Structure
1.657 sec → 4.233 sec
8
Typical Floor Plan
27-story
Base-isolated structure
PURI MATAHARI
TOWER
JAKARTA
CTBUH 2014 Shangai Conference CTBUH 2014 Shangai Conference
Base-isolated Structure
1.899sec 3.755sec
Fixed-based Structure
Modal Participating Mass Ratios
Periode (%Mass)
9
ETABS Model BM Diagram of Core Wall Fixed-Base Isolated Base
V=77436 kN
V=39946 kN
V=19973 kN
V=12906 kN
Direction
Fixed-Base Isolated Base Base Shear vs Displacement (PUSH-1) Base Shear vs Displacement (PUSH-2)
45 6000
Non-linear Push-over Analysis
40
5000
V=77436 kN 35
V=39946 kN 30 4000
3000
20
V=19973 kN
ISOLATOR ISOLATOR
DISPLACEMENT DISPLACEMENT
15 2000
ROOF DISPLACEMENT ROOF DISPLACEMENT
V=12906 kN
10
1000
Direction
0 0
0 0.2 0.4 0.6 0.8 1 1.2 0 0.02 0.04 0.06 0.08 0.1
Displacement (m) Displacement (m)
10
Performance of Seismically Isolated Structure vs Conventional Structure
Fully Operational
R=2.0 CD=2.0
R=6.0 CD=5.0
Fema 356 CP
Fema 356 LS
Fema 356 IO
http://www.davysukamta.com
News / Articles / CTBUH2014
THANK YOU
11