Stress-strain Diagram
27-story 30-story
Superstructure Design
DBE = 2/3MCE
Loads may be reduced by seismic reduction factor R
R ≤ 2 allowing limited inelastic response
Level 1: DBE
superstructure
Vb
VS =
R1
Levelsub-structure
2: MCER
Isolation
Vb = kD max DD
Interface
Isolation System
Stiffness + 20%
Mean value stiffness
Stiffness - 20%
The maximum value of the response parameter of interest was used for design.
Period of interest
Isolation
Interface
Tower Seismic Gap
HDRB
16 HDRB HH130-6R
24 HDRB HH150-6R
17.6.2 Modeling
ETABS Model
Shear Link
Outrigger
C T
Shear Link
RC core wall
Outrigger
Fixed-base Structure
Outrigger Periode Periode
Column Nomor Getar Nomor Getar Faktor Partisipasi Mass (%)
Dynamic Characteristic of
Based-Isolated vs Fixed-Base Structure
1.657 sec → 4.233 sec