Strong points
6
7 6. Reset key. Minimum current (Imin) 50 mA(1)
8
7. Metrological LED. Transition current (Itr) 250 mA(2)
8. Programming key. Reference current (Iref) 5 A(3)
3 4 Permanent overload (Imax) 6A
Intermittent overload 120 A for 0.5 s
Voltage measurement
Range of measurement 230 ... 400 V +/- 20 %
Case Consumption (VA) 2 VA
Permanent overload 280 V phase-neutral / 480 V phase-phase
62.5 Energy accuracy
72 45 Active (according to IEC 62053-21) Class 0,5s
Active (according to EN 50470) Class C (E42/44/E46)
Power supply
Self-supplied yes
COUNTIS E40
Error Partial
Frequency 50 / 60 Hz
count_193_b_1_x_cat
45
PROG
RESET
Number 1
3X230(400)VAC 50/60Hz 0.05-5(6)A
C=0.1Wh/imp Type of optocoupler IEC 62053-31 Class A (20 ... 30 VDC)
Pulse weight 100 Wh, 1 kWh, 10 kWh, 100 kWh
50 ms, 100 ms, 200 ms, 400 ms, 800 ms,
Pulse duration
1000 ms, 1500 ms
Operating conditions
Type modular Operating temperature -10 to 55 °C
Number of modules 4 Storage temperature -20 to 70 °C
Dimensions W x H x D 73 x 90 x 62.5 mm Relative humidity 85 %
Case degree of protection IP20 Communication E43/E44 E45/E46
Front degree of protection IP51 Link RS485 Connection
Display type backlit LCD display Type 2 half duplex wires 2 half duplex wires
Rigid cable cross-section 1.5 to 10 mm2 Protocol MODBUS RTU M-BUS
Flexible cable cross-section 1 to 6 mm2 Speed 4800 … 38400 bauds 300 … 9600 bauds
Weight 230 g (1) I(min) ≤ 0.5 * Itr
(2) The accuracy class is guaranteed between Itr and Imax.
(3) I(ref) = I(b) (base current) = 10 * I(tr) for direct connection COUNTIS.
Connection
Recommendation:
- For IT earthing systems, it is recommended that the CT secondary is not connected to earth.
- When disconnecting the COUNTIS, the secondary of each current transformer must be short-circuited. This operation can be carried out automatically by a
SOCOMEC PTI, an accessory which is included in this catalogue. Please consult us.
N N N
L1 L1 L1
L2 L2 L2
L3 L3 L3
count_189_f_1_x_cat
count_187_d_1_x_cat
count_186_c_1_x_cat
1 1 1 1 1 1 1 1 1
+ - + - + -
4 6 12 14 16 2 1 3 5 7 9 11 RS485 12 14 16 2 1 3 5 7 9 11 4 6 8 10 12 14 16 2 1 3 5 7 9 11
U1 U2 U3 N S1 S2 S1 S2 S1 S2 U1 U2 U3 N S1 S2 S1 S2 S1 S2 T1/2 U1 U2 U3 N S1 S2 S1 S2 S1 S2
L1 L2 L3 L1 L2 L3 L1 L2 L3
COUNTIS E40 COUNTIS E43/E44/E45/E46 COUNTIS E41/E42
1. Fuses 0.5 A gG / 0.5 A class CC.
References
COUNTIS COUNTIS COUNTIS COUNTIS COUNTIS COUNTIS COUNTIS
E40 E41 E42 E43 E44 E45 E46
Type Reference Reference Reference Reference Reference Reference Reference
Via CT 4850 3008
Via CT - Dual tariff 4850 3009
Via CT - Dual tariff - MID 4850 3015
Via CT - Dual tariff with RS485 MODBUS com.(1) 4850 3017
Via CT - Dual tariff with RS485 MODBUS com. - MID(1) 4850 3014
Via CT - Dual tariff with M-BUS com.(1) 4850 3027
Via CT - Dual tariff with M-BUS com. - MID(1) 4850 3028
Management software for COUNTIS See page 142
(1) 4 tariffs through RS485 communication.