This document provides information on 13 transmission line towers (T1 to T13) that are part of a 132kV transmission line between Bijnaur and SGPGI. It includes details like the tower type, span length, angle with turn, objects in the span, rivement type, vibration damper type, and coordinates of each tower location. It also lists general information about the transmission line such as the voltage level, conductor configuration, ownership details, earth wire type, and reactance/resistance values.
This document provides information on 13 transmission line towers (T1 to T13) that are part of a 132kV transmission line between Bijnaur and SGPGI. It includes details like the tower type, span length, angle with turn, objects in the span, rivement type, vibration damper type, and coordinates of each tower location. It also lists general information about the transmission line such as the voltage level, conductor configuration, ownership details, earth wire type, and reactance/resistance values.
This document provides information on 13 transmission line towers (T1 to T13) that are part of a 132kV transmission line between Bijnaur and SGPGI. It includes details like the tower type, span length, angle with turn, objects in the span, rivement type, vibration damper type, and coordinates of each tower location. It also lists general information about the transmission line such as the voltage level, conductor configuration, ownership details, earth wire type, and reactance/resistance values.
Unit of Tower Tower Description Tower Type of Span Tower Measure Angle with (Nala/CT Rivement Type of Vibration Number Type Foundation Length Location Turn Road/Metal (Yes/No) insulator Damper (Meter) Road/NH/etc. (Building/Tree/Br (0,1,2,4) idge etc.) SGAN START GANTRY-132GANTRY 0 0 M 00°00'00'' T1 TOWER 1 DB+0 20 20 M 12°47'16''RT T2 TOWER 2 DC+0 345 365 M 00°28'11''LT T3 TOWER 3 DB+5 290 655 M 20°00'48''LT T4 TOWER 4 DB+0 350 1005 M 19°34'52''RT T5 TOWER 5 DB+0 375 1380 M 07°37'55''RT T6 TOWER 6 DB+5 288 1668 M 13°59'36''RT T7 TOWER 7 DB+5 196 1864 M 32°56'53''LT T8 TOWER 8 DC+0 350 2214 M 21°32'02''LT T9 TOWER 9 DB+5 240 2454 M 26°41'23''RT T 10 TOWER 10 DB+0 300 2754 M 22°10'34''LT T 11 TOWER 11 DB+0 325 3079 M T 12 TOWER 12 DA+0 325 3404 M 09°43'16''RT T 13 TOWER 13 DB+0 330 3734 M 14°05'51''LT EGAN END GANTRY-SGPGI DC+0 50 3784 M 00°00'00'' Vibration Corona Anti Copper Arcing Phase Number Danger No. of No. of damper Ring Horn Plate Plate Plate Climbing Earthing Circuit No. of OPGW Spacer on on earth bond for Latitude in Longtitude in (Yes/No) Device Type Earth wire (Yes/No) Earth wire decimal decimal (Yes/No) (Yes/No) (Yes/No) (Yes/No) the Span wire (Yes/No) (Yes/No) (Yes/No) 26.71157277 80.8978255 26.71141033 80.89792618 26.70844049 80.89889395 26.70592198 80.89969036 26.70335919 80.90175344 26.70013657 80.90280168 26.69757264 80.9032361 26.69584799 80.90305662 26.69314954 80.9048582 26.69179643 80.90672897 26.68935943 80.9079874 26.68739262 80.91034102 26.68540772 80.91271468 26.68309749 80.9146764 26.68286299 80.91509871 Critical/ Vulnurable Ground Tower location with clearance Design reason (in Meter) Transmission Line Name 132kV BIJNAUR-SGPGI CKT1 Circuit Type SINGLE CKT Zone 15-TC LUCKNOW Circle 114-ETC-I, LUCKNOW Division 159-ETD-I,LUCKNOW Sub-Division ETSD-III, LUCKNOW Voltage level 132kV SIL (Surge Impedance Load) 80 MW Conductor Configure PANTHER Date of comissioning Ownership 159-ETD-I,LUCKNOW(T1 TO T13) ALDC/SLDC SLDC OCC/NRPC NRPC DISCOM NO Earth wire OPGW +ve Reactance/Km Not to be filled +ve Resistace/Km Not to be filled Zero sequence reactance/Km Not to be filled Zero sequence resistance/Km Not to be filled Mutual coupling reactance/Km Not to be filled Mutual coupling resistance/Km Not to be filled For Exp.-NO/MVVNL/PVVNL/PuVVNL/DVVNL/KESCO/NPCL