Harnessing the
power of water
Generating electricity from the power of water represents large
amounts of clean, renewable energy. Seventy-one percent of the
earth’s surface is covered by water. So far, the installed world´s
hydropower potential is 4 million GWh/year. There remains a
huge hydropower potential of 16 million GWh/year.
2
1 Hongrin-Léman, Switzerland
Source: Forces Motrices Hongrin-Léman SA, Switzerland
2 Upper reservoir Latschau, Rodund II, Austria
3 Rodund II, Austria
3
4
4
5 6
The first pumped storage station in Germany was installed in Today, more than 450 Voith pumped storage units have
1908, when Voith constructed an uphill water storage tank for beeninstalled wordwide with a combined output of well over
turbine tests in the Brunnenmühle and used it to operate 60 000 MW. Whether a reversible pump turbine or a turbine
pumps and turbines. and a pump combination, these machines have proven to be
extremely durable. In many cases they have performed reliably
In 1937, Voith developed the first large, single-stage pump for several decades.
turbine, which operated both as a turbine for energy genera-
tion and, in the reverse direction, as a pump.
5
Characteristics of reversible
pump turbines
Progress in technology are constant, including
the latest developments on variable-speed and
wide head range applications.
1 000
3 Lewiston 43 Guangzhou II
61 58
54
7 Coo I 44 Edolo (5 stage)
60
29 59 56 12 Raccoon 45 Goldisthal
36 49 43
31
47 55 42 53
52 14 Rodund II (two variable speed)
21
35 24
14 39 57
21 Bath County 47 Venda Nova
50 27 22 Coo II 48 Tai An
7 51
44 34
45 12 24 Estangento 49 Siah Bishe
38 22 48 25 Gabriel y Galan 50 Waldeck I
K = nq √ H 27 Kühtai 51 Limberg II
Pump head H (m)
x
37 29 Obrovac 52 La Muela II
Q0.5
nq = n x 31 Presenzano 53 Ingula
H0.75
100 34 Palmiet 54 Reiseck II
35 Bad Creek 55 Frades II
36 La Muela 56 Hong Ping
25
37 Herdecke 57 Lamtagong
K
39 Mingtan 59 TianChi
1 0
3
00
42 Shisanling 60 XiaMen
K
=
K
=
=
20
40
60
0
10
10 20 40 60 80 100 200
Specific speed (nq)
6
7 8
7 Goldisthal, Germany
8 Limberg II, Austria
Application range
1 000
Pump turbine
Head (m)
100
10
1 10 100 1 000
Output (MW)
7
Characteristics of storage pumps
and torque converters
Worldwide, Voith has earned a reputation as a major pump manufacturer.
Many pumped storage plants work smoothly with Voith equipment. It’s
the efficiency and longevity that matters when running pumped storage
plants. Our strength: reliable customized solutions.
Pumps for storage applications are mainly of the radial-flow The start-up of the storage pump begins already during
type. Depending on the application conditions, the construction the filling process. As the pressure level of the filling water
can be a single-flow or double-flow, as well as single-staged rises, the torque output by the converter increases and thus
and multi-staged. accelerates the pump.
Torque converter This acceleration torque, which is initially very high, continu-
The torque converter provides the most time efficient startup ously decreases as secondary speed rises. When reaching the
and shutdown of a storage pump. Within seconds the storage synchronous speed, the converter output torque corresponds
pump can be connected or separated from the shaft system. to the pump priming torque.
It transmits torque and / or power from the motor generator to Due to the soft interaction of these processes, the storage
the pump shaft by being filled with process water. pump can be started up quickly. No load surges for the grid
occur.
10 000
1 000
Radial-flow pumps
Head (m)
100
0
1 10 100 1 000
Output (MW)
8
Ternary sets fast change over between turbine and pump mode.
Ternary sets consist of a motor generator, a separate turbine Full regulating capability exists in both, the turbine and the
(typically Francis or Pelton) and a pump set. As two separate pump mode operation from 0 % to 100 % of the unit output.
hydraulic machines, the rotational direction of the motor
generator
Couplingcanto be the same in both operational modes. This Hydraulic short circuit
motor-generator
results in considerable commercial value for the power plant’s By using the hydraulic short circuit concept almost the full
operation. For switching between turbine and pump operation, power range of the plant is available. Moreover, this applica-
the following components can be provided: a clutch operable tion helps to control the energy flow into the grid. The principle
at standstill, a starting turbine or a synchronizing tourque of this operation mode is based on the idea that only the
converter. With the configuration of a ternary set the, so-called difference between the constant pump load and the flexible
hydraulic short circuit within the machine set can be imple- turbine output, both rotating on one common shaft, should
mented.
PeltonItturbine
offers the best answer for a very fast grid response, come to the grid.
being carried out with the torque converter which allows
Coupling to
motor generator
Pelton turbine
Torque converter
Storage pump
Torque converter
Storage pump
9
Motor generator characteristics
Since the early beginning of manufacturing hydropower plants, Voith has
supplied the world’s largest and most powerful units in performance and
size at their time. Voith always managed to go beyond limits.
Power demand increases with a growing economy and the Our technology sets us apart
improvement of living standards. Following this trend, the • Motor generator technology – including excitation, static
capacity of power supply units has increased continuously. frequency converters (SFC) and SCADA systems.
• Well advanced and proven VPI insulation system for
From the early 20th century, Voith has manufactured outstand- optimized design for Class 155 according IEC (formerly
ing motor generators, for instance. The world’s most powerful Class F) and voltages up to 25 kV.
motor generators for Bath County (USA), delivered in 1976. • Air-cooled by RIM-ventilation or forced ventilated, or direct
20
600 16 Samrangjin, South Korea
17 Bath County MOD, USA
18 Frades II (DFIM***), Portugal
500 19 Chang Long Shan, China
13 17
18 20 Belo Monte, Brazil
15
400 12
21 Guri II, Venezuela
14 19 22 Itaipu, Brazil / Paraguay
16
23 Three Gorges, China
300 24 Xi Luo Du, China
8
6 25 Wu Dong De, China
200 11
7
5 Water-cooled
100 Air-cooled
3 4 Hydrogen
9 10
1 2
0 * Mega volt ampere
1900 1910 1920 1930 1940 1950 1960 1970 1980 1990 2000 2010 2020 ** Synchronous Condenser
*** Doubly Fed Induction Machine
Year
Lorem ipsum
10
The following design criteria influence the generator’s To achieve optimum economics, larger unit capacity machines
main dimensions: are often being designed in order to reduce the number of
• In order to ensure a long and reliable operation, it is units at each plant. In addition, high-speed rating is another
essential that operational temperatures are aligned with important factor for smaller volume machines. Direct water-
the allowable limits of the materials, especially those of the cooling is a very effective method in compact machines. Voith
winding with respect to the applied insulation system. has vast references in both air-cooled and water-cooled
• The required moment of inertia must be provided within machines as shown below.
the given stator bore dimensions.
• At runaway speed the mechanical stress incurred by All Voith generators are designed and manufactured with the
the rotating parts shall be designed within the maximum latest state-of-the-art technology including the use of Vacuum
allowable stresses of the specific material and load Pressure Impregnation (VPI) for the stator bars and coils.
universe for static as well as dynamic integrity. Rated voltages up to 25 kV are part of our standard produc-
• A safety margin is provided between the first critical speed tion.
and the unit’s runaway speed. A shorter and lighter rotor
helps to achieve this margin.
• For air-cooled machines, a shorter core length and a larger
Three Xi Luo Du
850 Gorges
Itaipu 50 Hz
Grand Guri II
Coulee
550
Revelstoke 5
Bath County MOD
Rating (MVA)
250
Chongpyong Malta Air-cooling
150 Akköy II
50
0
0 100 200 300 400 500 600 700 800 900 1 000
Speed (rpm)
11
9
Mastering the
challenges of changing
energy systems
Today, the energy and grid industry is undergoing a rapid transformation.
Trends such as distributed energy, renewables and digitalization
are influencing increasingly complex network models and regulatory
requirements. As multi-functional power plants, pumped storage
facilities have a high potential to meet this challenge, as their technology
is based on the only long-term, technically proven and cost-effective
form of storing energy on a large scale.
12
Pumped storage plants supply the physically fixed base-load Due to the increasing importance for the integration of renew-
energy, but can also support the grid with rapid power changes able energies into the electricity market, Voith develops
in the event of forecast deviations and faults. This makes them solutions for customers’ renewable portfolio management.
a guarantee for grid stability and security of supply. Our experts provide support for grid issues and complex grid
modeling.
Pumped storage technology is needed to facilitate increasing
quantities of variable renewables, which require a backup to Combining wind mills and/or solar farms with a pumped
ensure the stability of power systems. storage plant – so-called hybrid solutions – ensures that the
energy generated is immediately and reliably stored when it
cannot be directly fed into the power grid.
Integration of renewables
13
10 11
14
12 13
15
14 15
16
16 17
Storage pumps
17
18
18
19 20 3
Torque converters
19
VH3372, en, vvk, 2020-09. All data and information without obligation. Subject to change.