You are on page 1of 2

Dubai Central Laboratory

Construction Materials Laboratory Section - Structural Unit


TEST REPORT
COMPRESSIVE STRENGTH OF CONCRETE CORES

Report No: 100033637 Request No: EMTX-2017-004874

Project No: PS17-1010 Report Date: 02/02/2017


Project Name: CITY LAND MALL
Consultant: M.B.A ENGINEERING CONSULTANCY

Contractor: CHINA NATIONAL AERO TECHNOLOGY INTERNATIONAL ENGIN

Location: COLUMN

Source: NOT GIVEN


Sample Description: CONCRETE CORE
Sampling Date/Time: 02/01/2017 10:00 AM Lot Number: NG
Receiving Date/Time: 24/01/2017 08:00 AM Lot Size: - NA
Sample Size: 3 pieces Sender No: C10 | C11 | C12
Material/Mix type: Laying Date/Production Date:

Nominal Size / Working Block Size L * T * H (mm) : 95 MM

TEST RESULTS
PARAMETERS RESULTS
CLASS OF CONCRETE N.G N.G N.G
DATE OF CAST N.G N.G N.G
DATE OF CRUSHED 29-JAN-2017 29-JAN-2017 29-JAN-2017
AGE AT TEST N.G N.G N.G
PART OF THE STRUCTUREOF THE C10 COLUMN C11 COLUMN C12 COLUMN
CORE
EXCESS VOIDAGE 0.5 0.5 0.5
PRESENCE OF CRACKS NO VISIBLE CRACK NO VISIBLE CRACK NO VISIBLE CRACK
ESTIMATED MAX. SIZE OF 20 20 20
AGGREGATE
MIN LENGTH AS RECEIVED (mm) 192 184 196
MAX LENGTH AS RECEIVED (mm) 200 190 205
EVIDENCE OF REINFORCEMENT THERE IS NO THERE IS NO THERE IS NO
EVIDENCE OF ANY EVIDENCE OF ANY EVIDENCE OF ANY
STEEL BARS IN THE STEEL BARS IN STEEL BARS IN
GIVEN SPECIMEN. THE GIVEN THE GIVEN
SPECIMEN. SPECIMEN.
SURFACE MOISTURE CONDITION AT WET WET WET
TIME OF TE
METHOD OF END PREPARATION BY CAPPING BY CAPPING BY CAPPING
TEST METHOD VARIATION NIL NIL NIL

SPECIMEN # C10 C11 C12


DIAMETER OF THE CORE (mm) 94 94 94
RATIO L/D 1.1 1.1 1.1
MEASURED COMPRESSIVE 29.4 37.2 28.7
STRENGTH (N/mm2)
ESTIMATED INSITU STRENGTH 30.0 38.0 29.2
N/mm2

This Report is computer approved and authorized by Structural Unit


It does not require any signature

Doc. Ref: F-EM-0100 Rev.No :1


Issue Date: 03/10/2016 Page :1 of 2
P.O. BOX: 67 DUBAI, TEL : 00971-4-3369900, FAX : 00971-4-3366399
E-mail: labs@dm.gov.ae Website: http://www.dm.gov.ae
Dubai Central Laboratory
Construction Materials Laboratory Section - Structural Unit
TEST REPORT
COMPRESSIVE STRENGTH OF CONCRETE CORES

Report No: 100033637 Request No: EMTX-2017-004874

Sampled By: ALI MOHAMMED (CONSULTANT) Tested By: RARAYMUNDO


Samples Brought By: ALI MOHAMMED (CONSULTANT) Testing Date: 01/02/2017 12:04 PM
Sampling Method: BS 1881 PART 120 : 1983 ( AMD 6109 : 1989 ) Sampling Report No:
Test Method: BSEN 12504-1:2009 Test Method Variation: -

Remarks: NIL

To verify this document please go to http://login.dm.gov.ae/wps/portal/documentverification and


Enter Document ID: EMTX-2017-004874 and Verification Code: 065-256 or scan the QR code below.

This Report is computer approved and authorized by Structural Unit


It does not require any signature

Doc. Ref: F-EM-0100 Rev.No :1


Issue Date: 03/10/2016 Page :2 of 2
P.O. BOX: 67 DUBAI, TEL : 00971-4-3369900, FAX : 00971-4-3366399
E-mail: labs@dm.gov.ae Website: http://www.dm.gov.ae