3406C Generator Set 9ES00001-UP(SEBP2752 - 15) - Document Structure Página 1 de 1

Shutdown SIS

Previous Screen

Product: GENERATOR SET


Model: 3406C GENERATOR SET 9ES
Configuration: 3406C Generator Set 9ES00001-UP

Testing and Adjusting


VR6 Voltage Regulator
Media Number -RENR2480-04 Publication Date -01/12/2007 Date Updated -17/12/2007

i02655646

Voltage Regulator - Replace


SMCS - 4467-510

1. Install the voltage regulator. Refer to the installation instructions. See the Testing and
Adjusting, "Wiring Diagrams".

2. Start the engine.

3. Run the engine at rated engine RPM and at no load.

4. Turn the knee frequency adjustment counterclockwise (CCW).

5. Adjust the voltage level. Refer to the Testing and Adjusting, "Voltage - Adjust".

6. Adjust the knee frequency. Refer to the Testing and Adjusting, "Knee Frequency - Adjust".

7. Adjust stability. Refer to the Testing and Adjusting, "Stability - Adjust".

8. Return the genset to normal operation.

9. Add load to the genset.

10. Slightly reduce the frequency of the genset. Generator voltage should decrease proportionally
with the frequency. Otherwise, readjust the knee frequency again.

11. Increase the frequency to the rated frequency.