You are on page 1of 3

3406C Generator Set 9ES00001-UP(SEBP2752 - 15) - Document Structure Página 1 de 3

Shutdown SIS

Previous Screen

Product: GENERATOR SET


Model: 3406C GENERATOR SET 9ES
Configuration: 3406C Generator Set 9ES00001-UP

Testing and Adjusting


VR6 Voltage Regulator
Media Number -RENR2480-04 Publication Date -01/12/2007 Date Updated -17/12/2007

i02655758

Stability - Adjust
SMCS - 4467-025

Illustration 1 g00779264
VR6 Voltage Regulator

(1) Stability adjustment

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 16/02/2009
PDF created with pdfFactory trial version www.pdffactory.com
3406C Generator Set 9ES00001-UP(SEBP2752 - 15) - Document Structure Página 2 de 3

Illustration 2 g01021519

The Cat VR6 presents an electrical shock/electrocution hazard. This


hazard will cause serious injury or death.

Service by trained personnel only.

The terminals and heat sinks are live at hazardous voltages when power
is applied and for up to 8 minutes after power is removed.

An oscilloscope or other voltage recording device should be used if an optimal stability setting is
desired. Rotate stability adjustment (1) in the clockwise (CW) direction if you need to slow the
response time. Rotate stability adjustment in the counterclockwise (CCW) direction if you need to
speed the response time. If the adjustment is rotated too far in a CCW direction, the generator
voltage may oscillate or the voltage may hunt.

Good response can be obtained with the following procedure:

1. Start the generator.

2. Run the generator at no load.

3. Rotate stability adjustment (1) CW until the voltage becomes stable.

4. Rotate stability adjustment (1) CCW until the system just begins to oscillate.

5. Rotate stability adjustment (1) CW just past the point at which oscillation occurred.

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 16/02/2009
PDF created with pdfFactory trial version www.pdffactory.com
3406C Generator Set 9ES00001-UP(SEBP2752 - 15) - Document Structure Página 3 de 3

Note: If the voltage remains stable when the adjustment is fully CCW, leave the adjustment fully
CCW. This gives the fastest response to load changes.

Copyright 1993 - 2009 Caterpillar Inc. Mon Feb 16 15:12:35 EST 2009
All Rights Reserved.
Private Network For SIS Licensees.

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/s... 16/02/2009
PDF created with pdfFactory trial version www.pdffactory.com