Professional Documents
Culture Documents
线缆安装指南
Part Number: 31043915 Issue: 05
部件编码: 31043915 文档版本: 05
NOTE/说明
4. The protection caps of antenna ports not connecting to cables
1. Only qualified personnel are allowed to install the antenna. must not be removed. In addition, waterproof measures must
天线的安装需由合格的安装人员操作。 be taken to protect the antenna ports.
2. The appearance of the antennas shown in the figures is only for 对于不接线缆的所有天线端口其防护帽不能拆下,并同时需做好
reference and may differ from the actual one. 防水处理。
部分图示与实物可能稍有差别,具体情况请以实物为准。 5. The cold shrink tubing must be replaced promptly when
3. During installation, the water leakage hole must face cracks are found.
toward the ground, and the corresponding cable connector 使用过程中,若发现冷缩套管有裂纹,必须及时更换。
must be waterproofed.
天线安装时,漏水孔需朝下,对应线缆接头需做防水处理。 6. Cluster connectors and the connectors of extension cables
need to be waterproofed with one layer of insulation tape,
three layers of waterproof tape, and another three layers of
insulation tape (including RF cables and AISG cables).
集束接头和线缆延长对接接头需进行1层绝缘胶带+3层防水胶
带+3层绝缘胶带防水处理(包含射频线缆和AISG线等)。
Marker
记号笔
Utility knife
美工刀
AISG extension cable
AISG延长线
Diagonal pliers
斜口钳 MQ/Cluster straight-through cable (> 0.5 m)
MQ/集束直连线缆(长度大于0.5m)
Other RF cable
其他射频跳线
Torque wrench
Size: 18 mm, 22 mm, 32 mm, 36 mm
力矩扳手
开口:18mm、22mm、32mm 、36mm Cold shrink tubing
Insulation tape Waterproof tape (optional)
绝缘胶带 防水胶带 冷缩套管(可选)
*09310439151X220301HW* 1
Copyright © Huawei Technologies Co., Ltd. 2022. All rights reserved.
版权所有 ©华为技术有限公司2022。保留一切权利。
Bending Radius Requirements for General Cables
通用线缆弯曲半径要求
Connect the jumper to the antenna port. Tighten the screw on the jumper using a torque wrench. The
连接跳线到天线端口。 tightening torque is 5–15 N·m for 4.3-10 connectors.
使用力矩扳手拧紧跳线接口,4.3-10型连接器的紧固力矩是
5N·m~15N·m。
22 mm
2
Scenario 2: DIN Connectors Are Used
场景二:天线接头为DIN型接头
Connect the jumper to the antenna port. Tighten the screw on the jumper using a torque wrench. The
连接跳线到天线端口。 tightening torque is 25 N·m for DIN connectors.
使用力矩扳手拧紧跳线接口,DIN型连接器的紧固力矩是25N·m。
32 mm
Connect the jumper to the antenna port. Tighten the screw on the jumper using a torque wrench. The
连接跳线到天线端口。 tightening torque is 1.1 N·m for N connectors.
使用力矩扳手拧紧跳线接口,N型连接器的紧固力矩是1.1N·m。
18 mm
3
Scenario 4: MQ Connectors Are Used
场景四:天线接头为MQ接头
1 3
3
1
4
Scenario 5: Cluster Connectors Are Used
场景五:天线接头为集束接头
1
3
1 3
3
1. Cluster female connectors, used to connect antenna ports.
集束母头连接器,用于连接天线端口。
2. Cable labels.
线缆标签。
3. Type N female connectors, used to connect RF cables.
N型母头连接器,用于连接射频线缆
5
NOTE/说明
1. Select cable lengths and connector types according to installation scenarios to make sure the cable connectors match the
antenna and RRU connectors.
根据实际的安装场景,选用合适的线缆长度和接头类型,确保天线和RRU端口与所选线缆接头匹配。
2. The installation method and tightening torque in scenarios 4 and 5 are the same. The following installation uses scenario 4
as an example.
场景四和场景五安装方式及安装紧固力矩相同,本文安装步骤以场景四作安装示例。
Connect the MQ cable to the antenna port. Align two Tighten the screw on the cable with the torque 20 N·m.
red anchor points. 拧紧跳线接口, 紧固力矩为 20N·m 。
连接MQ线缆到天线端口,两个红色的安装定位点要对准。
Connect the MQ cable to the antenna port. Align two Tighten the screw on the cable with the torque 20 N·m.
red anchor points. 拧紧跳线接口, 紧固力矩为 20N·m 。
连接MQ线缆到天线端口,两个红色的安装定位点要对准。
6
Based on the mapping of cable labels, connect the RF cables to the cluster branch line cables and tighten the connectors
using two wrenches. Tightening torques are as follows:
根据线缆标签的对应关系,将射频线缆安装到分支线线缆上。并用两个扳手紧固连接器。紧固力矩参考如下:
Type N
4.3-10 Connector DIN Connector
Connector
4.3-10型连接器 DIN型连接器
N型连接器
Double-wrench tightening
双扳手操作
Torque wrench Combination wrench
力矩扳手 组合扳手
NOTE/说明
For double-wrench tightening, use the combination wrench to fix the female cable connector, while using the
torque wrench to tighten the male cable connector clockwise.
双扳手操作时,请用组合扳手固定线缆母头连接器不动,用力矩扳手顺时针拧紧线缆公头连接器。
7
Install RF Cables on the RRU
射频线缆在RRU侧的安装
Connect the other end of the cable to the ANT port at the bottom of
the RRU, and tighten it using a torque wrench. For details about the
tightening torque requirements, see the tightening torques for
different connectors.
依次将线缆另一端连接到RRU底部ANT接口,并用力矩扳手对接口进行紧
固。紧固力矩要求参考上文不同接头的紧固力矩。
NOTE/说明
For details about how to connect the antenna and RRU, contact local Huawei
engineers.
天线与RRU的连接方法,请联系当地的华为工程师。
Caution/注意
Ensure that the operating frequency band of the antenna port is consistent with that of the RRU. Otherwise, the system
performance will deteriorate, and in extreme cases, the equipment may be damaged.
要确保天线端口工作的频段与RRU保持一致。否则,系统性能会下降,在极端情况下,设备可能会损坏。
Antenna Antenna
天线 天线 RRU
RRU
8
Waterproofing
防水操作
Both waterproof tape and cold shrink tubing can be used for waterproofing.
本文介绍两种防水方式,第一种使用防水胶带,第二种使用冷缩套管。
Wrap one layer of insulation tape from the bottom Wrap three layers of waterproof tape from the bottom 50 mm
50 mm away from the RF jumper connector to the away from the RF jumper connector to the top of the connector.
top of the connector. 从射频跳线连接器底部50mm处开始缠绕到连接器顶部,缠绕三层
缠绕一层绝缘胶带(射频跳线连接器底部50mm处到 防水胶带。
连接器顶部) 。
Wrapping
direction of three
layers of
waterproof tape
三层防水胶带走向
50 mm
50 mm
Cable ties
扎带
30 mm
NOTE/说明
1. When wrapping the insulation tape, ensure that the upper layer covers more than 50% of the lower layer. Wrap each layer
around the jumper tightly.
缠绕胶带时,须保证上一层胶带覆盖下一层的50%以上,每缠一层都要拉紧压实。
2. Before wrapping the waterproof tape, stretch the tape till the width of the tape becomes 1/2 of the original.
缠绕防水胶带时,均匀拉伸防水胶带,使其宽度为原宽度的1/2后再缠绕。
9
b Installation When a Cold Shrink Tubing Is Used 使用冷缩套管
NOTE/说明
Before using a cold shrink tubing, contact Huawei engineers to check whether the cold shrink tubing matches the cable.
使用冷缩套圈前请联系华为工程师确认套管是否与线缆匹配。
Route the RF cable through the cold shrink tubing. Tighten the screw on the jumper using a torque wrench.
Note that the RF cable must be routed in the opposite Tightening torques are as follows:
direction of the arrow marked on the cold shrink tubing. 使用力矩扳手拧紧跳线接口。紧固力矩参考如下:
将射频跳线穿过冷缩套管,注意冷缩套管的箭头方向,箭头
背向接头连接端。
Slowly rotate the cold shrink tubing Observe the shrink status of the
Push the cold shrink tubing
anticlockwise while keeping the tubing cold shrink tubing. Stop rotating
against the end cover of the
touching the end cover of the antenna. At the tubing when the tubing starts
antenna.
the same time, slowly pull downwards the shrinking at the root of the
将冷缩套管上推紧贴天线端盖。
supporting core from the cold shrink tubing. connector.
逆时钟方向缓慢转动冷缩套管并保持冷缩套管 观察冷缩套管的收缩状态,当冷缩
紧密接触天线端盖,同时向下缓慢抽拉冷缩套 套管开始收缩在接头根部时,不再
管支撑条。 转动冷缩套管。
10
Hold the cold shrink tubing so Release the cold shrink tubing The cold shrink tubing is installed
that it does not move upwards and pull the supporting core completely.
or downwards. Slowly pull the completely from the cold shrink 冷缩套管完成安装。
supporting core until the tubing in the arrow direction
connector is fully wrapped with marked on the tubing.
the cold shrink tubing. 冷缩套管完全包裹住接头后,可
紧握冷缩套管,保持冷缩套管不上 不再紧握冷缩套管,继续沿箭头
下移动,缓慢拉动支撑条,直到冷 方向抽出全部支撑条。
缩套管完全包裹住接头。
NOTE/说明
1. The cold shrink tubing should shrink at the root of the antenna
connector. The distance between the top of the cold shrink tubing
and the root of the connector must not exceed 2 mm. Otherwise,
H
reinstall the cold shrink tubing.
冷缩套管应尽量收缩在天线接头根部,冷缩套管顶部距离接头根部距
离不超过2mm(H<2mm),若超过2mm则更换新套管重新安装。
2. Do not forcibly pull the supporting core from the cold shrink
tubing. If resistance exists, rotate the supporting core while
pulling it in the arrow direction.
如果抽拉不顺畅,请勿强行拉拽,应一边沿箭头方向抽拉一边绕着线
缆旋转支撑条。
Cable ties
扎带
Recommended waterproofing method: One layer of insulation tape + three layers of waterproof
tape + three layers of insulation tape
推荐防水处理方法:1层绝缘胶带+3层防水胶带+3层绝缘胶带
For particular installation, please contact Huawei Technologies Co., Ltd. www.huawei.com
如需特殊安装请联系 华为技术有限公司, 网址:www.huawei.com
11 2022-03