it produces all of the information needed for the norms ISO 15189:2013 and ISO 23162:2021 accreditations.
by recording image sequences and results. Measurement errors due to human factors are minimized in the
analysis of human sperm.
WIDELY VALIDATED
Various studies have shown that the SCA® provides reliable, linear and accurate results with less variability
than manual methods, giving higher predictive values when diagnosing fertility problems4.
1 (WHO laboratory manual for the examination and processing of human semen Sixth edition 2021)
2 (Maree L., du Plessis S.S.,. Menkveld R,. van der Horst G, Human Reproduction 2010)
3 (Mukhopadhyay D, Varghese AC, Nandi P, Banerjee SK, Bhattacharyya AK. Andrologia, 2010)
4 (Dearing C G, Kilburn S, Lindsay K. S., Human Fertility, 2013)
ADAPTATION AND FLEXIBILITY
SCA® EDITIONS
Several editions with options adapted to give users a choice that will suite their needs:
Human Research
Full version, with all the features included for Full version to analyse human and animal sperm
human andrology and IVF labs, sperm banks, focused on research centres.
fertility clinics, hospitals, etc.
ADDITIONAL MODULES
Enable to complete your SCA® CASA system:
SCA® dataShare SCA® Stage Controller SCA® Manual counter
It enables the internal SCA® Fully automation using motorized Manual counter of any biological
database sharing and a stage. sample.
bidirectional connection with any
LIS system.
COMPLEMENTARY SYSTEMS
Unitary systems that permit to capture, view or edit SCA® files:
SCA® Capture SCA® Editor SCA® Viewer
Image capture software to use in Software that allows the opening Free software that allows to
connection with a main of SCA® sessions enabling to edit display SCA® analysis in any
SCA® station. or reanalyze. computer.
SCA® EVOLUTION:
A STATE-OF-THE-ART CASA
Since its launch in 1997, the SCA® sperm analyser has been in continuous
development, improving with each version the detection and analysis algorithms.
Combined with the latest state-of-the-art technology,
SCA® becomes the ultimate CASA research tool.
1
www.leapmotion.com
OUR OBJECTIVE:
WARRANTY AND TRUST IN THE DIAGNOSTICS
Reference: 1001 Code Patient: 001 Patient: Surname, First Name Date: 20/12/2011
*1001* *001*
Motility & Concentration
WHO5 23,77%
Velocity 21,51%
WHO4 14,72%
9,06%
Date
Doctor
20/12/2011
Non-progressive (NP)
Rapid
Medium
Slow
Immotile (IM)
Rapid progressive (type A)
Immotile (IM)
Collection date 20/12/2011 08:31 Collection method Laboratory
Volume (mL) 2,50 (Ref: > 1.5 ml) pH 7,50 (Ref: > 7.2) Concentration Measure of progression velocity
Temperature (ºC) 37 Abstinence days 3 (Ref: 2-5) 32
Collection difficulties No Complete Sample Complete 28,04
28
Liquefaction 60min (Ref: > 60min) Aggregation Normal
24
Viscosity Normal Agglutination 1A
Appearance Normal Cellular elements Normal 20
15,87
Treatment 16
12
8 6,67
Diagnostic 5,50
4
Asthenozoospermia 0
Progressive (PR)
Non-progressive (NP)
Concentration
20% 18,00%
WHO4
1/3 3/3
MINIMUM REQUIREMENTS:
SCA® SCA® SCA® SCA® SCA® SCA®
Motility and Morphology DNA Vitality Acrosome Leukocytes
Concentration Fragmentation reaction
Desktop or laptop: Operating system Windows 10/11 (64 bits);
COMPUTER
Processor: Intel Core i5 or superior; RAM: 4 GB or superior; USB 3.0 port
MICROSCOPE Nikon, Olympus, Zeiss or Leica; Trinocular C-mount 1x; Turret condenser and centering telescope
Positive
OBSERVATION
phase Fluorescence Brightfield Brightfield Fluorescence Brightfield Fluorescence Fluorescence Brightfield
METHOD
contrast
OBJECTIVE 10x Ph+ 60x / 100x oil 10x 20x 40x Plan Fluor 40x
Long
Long Bandpass
bandpass Dual band
bandpass (EX 510-
(EX 330- (EX 387/480;
FILTERS Green (EX 330-380; Blue Green 560; - -
380; EM EM 433/530;
EM 420; EM 590;
420; DM 403/502)
DM 400) DM 565)
DM 440)
Disposable counting Sperm Stain,
chambers or Makler SpermBlue, Diff-
DISPOSABLES, Quik, Morphology Chromatin dispersion test Vitality Leukocytes
KITS, slides SCA,
FluoVit FluoAcro
kits (SCD) slides SCA slides SCA
STAININGS - FluoCount
Papanicolau,
Shorr