Overview, Installation and Maintenance

of Pumps, Valves and Piping

Course No: M07-004


Credit: 7 PDH

Elie Tawil, P.E., LEED AP

Continuing Education and Development, Inc.


22 Stonewall Court
Woodcliff Lake, NJ 07677

P: (877) 322-5800
info@cedengineering.com
Addendum Sheet
Overview, Installation and Maintenance of Pumps, Valves and Piping
Course # M07-004

ADDENDUM SHEET FOR OVERVIEW, INSTALLATION AND MAINTENANCE OF


PUMPS, VALVES AND PIPING - COURSE # M07-004

The modifications listed in this addendum sheet apply to the Naval Education and Training
Professional Development and Technology Center “Pumps, Valves, and Piping” NAVEDTRA
14104A training course, chapter 9.

Corrections as of December, 2020:

To prevent compatibility issues, and to ensure that the content of this document is accessible in its
entirety, the interactive educational clips that are part of the original document have been disabled.
The items listed below have been added/modified to preserve the information presented in the
original document.

Page Correction

9-3 Figure 9-2 – Volute pump. Interactive clip is disabled.

9-5 Figure 9-4 – Two-stage main feed pump with a casing wearing ring. Interactive
clip is disabled.

9-5 Figure 9-5 – Shaft sleeve. Interactive clip is disabled.

9-12 Figure 9-9 – Gear pump located above the tank. Interactive clip is disabled.

9-12 Figure 9-10 – Double-screw, low-pitch pump. Interactive clip is disabled.

9-14 Figure 9-13 – Simple jet pump. Interactive clip is disabled.

9-14 Figure 9-14 – Flexible couplings. Interactive clip is disabled.

9-17 Figure 9-18 – Cutaway view of a straight-flow globe valve. Interactive clip is
disabled.

9-18 Figure 9-19 – Gate stop valve (nonrising-stem). Interactive clip is disabled.

9-20 Figure 9-23 – Swing-check valve. Interactive clip is disabled.

9-20 Figure 9-24 – Lift-check valve. Interactive clip is disabled.

9-38 Figure 9-46 – Hydraulic filter assembly incorporating differential pressure.


Interactive clip is disabled.

All Text alignment and justification.


CHAPTER 9
PUMPS, VALVES, AND PIPING
As a Fireman, you must know the basic operating principles of various types of pumps and supporting
components, such as the different types of valves and piping used aboard ships. Some of the primary
uses of pumps are as follows:
• To supply feedwater to boilers
• To deliver fuel oil to oil-fired boilers
• To circulate coolants and lubricants in internal combustion engines
• To supply chemical feed in water purification systems
• To lift water from cells and distribute it throughout a system
• To discharge sewage into setting tanks or mains
• To pressurize and move liquids through a distribution system
With the knowledge gained in this chapter, you should be able to describe pumps, valves, and piping
systems in terms of their construction, function, and operation. The information in this chapter, as it is
throughout the book, is of a broad and general nature. You should refer to the appropriate
manufacturer’s technical manuals and/or ship’s plans, information books, and plant or valve manuals
for specific problems with individual equipment. By studying this material, you should be able to relate
to the specific equipment found on your ship.

LEARNING OBJECTIVES
When you have completed this chapter, you will be able to do the following:
1. Recognize the principles of pump operation.
2. Identify the different types of pumps.
3. Identify an eductor.
4. Identify basic types and functions of valves.
5. Identify the types of steam traps.
6. Identify the different types of strainers.
7. Recognize the different types of filters.
8. Identify tubing and associated fittings.
9. Identify piping, associated fittings, and flange shielding.
10. Identify the types of packing and gasket material.

PUMPS
Pumps are used to move any substance that flows or that can be made to flow. Most commonly, pumps
are used to move water, oil, and other liquids; however, steam and other gases are also fluid and can
be moved with pumps, as can molten metal, sludge, and mud.

9-1
A pump is a device that uses an external source of power to force fluid to move from one place to
another. A pump develops no energy of its own; it merely transforms energy from the external source,
such as a gasoline or electric motor, into mechanical kinetic energy, which is manifested by the motion
of the fluid. This kinetic energy is then used to do work, for example, to raise liquid from one level to
another, as when water is raised from a well; to transport liquid through a pipe, as when oil is moved
through an oil pipeline; to move liquid against some resistance, as when water is pumped to a boiler
under pressure; or to force liquid through a hydraulic system against resistance. Every pump has a
POWER END, whether it is a combustion engine or some type of electric motor. Each pump also has
a FLUID END, where the fluid enters (suctions) and leaves (discharges) the pump.
When a pump delivers energy to a liquid, it usually causes an increase in pressure, which is generally
referred to as HEAD. There are four types of heads:
• Net positive suction head (NPSH)
• Suction head
• Discharge head
• Total head

Net Positive Suction Head (NPSH)


NPSH is the suction pressure minus the vapor pressure expressed in feet of liquid at the pump suction.
An example is a feed booster pump with a deaerating feed tank operating at saturated conditions. The
NPSH on this pump equals the pressure resulting from the height of the water above the booster pump
suction.

Suction Head
The suction head on a pump is the total pressure of the liquid entering the pump. In a deaerating feed
tank operating under saturated conditions, the suction head of the feed booster pump is equal to the
NPSH plus the auxiliary exhaust pressure.

Discharge Head
The discharge head is the pressure of liquid leaving the pump and/or the level of liquid with respect to
the level of the pump on the discharge side.

Total Head
The total head is the net difference between the suction head and the discharge head.
Suction head is usually expressed in feet of water if positive, and in inches of mercury if negative. When
a pump operates below the level of a liquid, its suction end receives the liquid under a gravity flow.
When the pump is located above the level of the liquid being pumped, the pump must be able to
establish a vacuum at the inlet to move the liquid into the pump. Atmospheric pressure, acting on the
surface of the liquid, will then provide the necessary pressure to move the liquid into the pump.
It is not practical or necessary to mention all of the various locations where pumps are found aboard
ship. You will learn their location and operation as you perform your duties. The pumps with which you
are primarily concerned are used for such purposes as providing fuel oil to the prime mover, circulating
lubricating (lube) oil to the bearings and gears of the main reduction gear (MRG), supplying seawater
for the coolers in engineering spaces, pumping out the bilges, and transferring fuel oil to various
storage and service tanks.

9-2
Classification of Pumps
Pumps aboard ships outnumber all other auxiliary machinery units. They include such types as
centrifugal, rotary, and jet pumps. In the following section we discuss these different pumps and their
application to the engineering plant.

Centrifugal Pumps
When a body or a liquid is made to revolve or whirl around a point, a force is created that impels the
body or fluid to move outward from the center of rotation. This phenomenon is called centrifugal force.
It is from this force that the centrifugal pump got its name. The fire pump and seawater service pump
are two examples of this type of pump.
A basic centrifugal pump has an impeller keyed to a drive shaft, which is rotated by an electric motor.
The drive shaft is fitted inside a casing, which has a suction inlet and a discharge outlet. Figure 9-1
shows the arrangement of components in a centrifugal pump.

Figure 9-1 — Centrifugal pump.

Types of Centrifugal Pumps


There are many different types of centrifugal pumps, but the two you are most likely to encounter
onboard ship are the volute pump and the diffuser pump.

Volute Pump
In the volute pump (Figure 9-2, views A and B), the impeller discharges into a volute (a gradually
widening spiral channel in the pump casing). As the liquid passes through the volute and into the

Figure 9-2 — Volute pump.


9-3
discharge nozzle, a great part of its kinetic energy (velocity
head) is converted into potential energy (pressure head).

Diffuser Pump
In the diffuser pump, the liquid leaving the impeller is first
slowed down by the stationary diffuser vanes that surround the
impeller. The liquid is then forced through gradually widening
passages in the diffuser ring and into the volute (casing). Since
both the diffuser vanes and the volute reduce the velocity of
the liquid, there is an almost complete conversion of kinetic
energy to potential energy.

Centrifugal Pump Classification


Centrifugal pumps may be classified in several ways. For
example, they may be either single-stage or multistage. A
single-stage pump has only one impeller; a multistage pump
has two or more impellers housed together in one casing. In a
multistage pump, each impeller usually acts separately,
discharging to the suction of the next stage impeller.
Centrifugal pumps are also classified as horizontal or vertical,
depending on the position of the pump shaft.
One method of increasing the discharge pressure of centrifugal
pumps is by providing additional impellers. Impellers used in
centrifugal pumps may be classified as single-suction or
double-suction, depending on the way in which liquid enters the
eye of the impeller. Figure 9-3 shows single-suction and double-
suction arrangements of centrifugal pump impellers. The single-
suction impeller (view A) allows liquid to enter the eye from one
side only; the double-suction impeller (view B) allows liquid to
enter the eye from both sides. The double-suction arrangement
has the advantage of balancing the end thrust in one direction
with the end thrust in the other direction.
Impellers are also classified as closed or open. A closed
impeller has side walls that extend from the eye to the outer Figure 9-3 — Centrifugal pump
edge of the vane tips; an open impeller does not have side impellers. A. Single-suction. B.
walls. Most centrifugal pumps used in the Navy have closed Double-suction.
impellers.

Construction
As a rule, the casing for the liquid end of a pump with a single-suction impeller is made with an end
plate that can be removed for inspection and repair of the pump. A pump with a double-suction impeller
is generally made so one-half of the casing may be lifted without disturbing the pump.
Since an impeller rotates at high speed, it must be carefully machined to minimize friction. An impeller
must be balanced to avoid vibration. A close radial clearance must be maintained between the outer
hub of the impeller and that part of the pump casing in which the hub rotates. The purpose of this is to
minimize leakage from the discharge side of the pump casing to the suction side.

9-4
Because of the high rotational speed of the impeller and the necessarily close clearance, the rubbing
surfaces of both the impeller hub and the casing at that point are subject to stress, causing rapid wear.
To eliminate the need for replacing an entire impeller and pump casing solely because of wear in this
location, most centrifugal pumps are designed with replaceable wearing rings. One ring is attached to
each outer hub of the impeller. This ring is called the impeller wearing ring. The other ring, which is
stationary and attached to the casing, is called the casing wearing ring (Figure 9-4).
In most centrifugal pumps, the shaft is fitted with a replaceable sleeve (Figure 9-5). These sleeves
protect the shaft from becoming grooved. A shaft that is in direct contact with the packing will become
grooved because of its rotation in the packing. It is much cheaper to replace the shaft sleeves than to
replace the pump shaft. The shaft sleeves are also used to position the impeller axially on the pump
shaft.

Figure 9-4 — Two-stage main feed pump


with a casing wearing ring.

Figure 9-5 — Shaft sleeve.


Stuffing Box
The stuffing box (Figure 9-6) is a chamber in the packing gland used to
seal the shaft where it passes through the pump casing. Packing rings
are placed inside of the stuffing box, and a gland is used to compress the
packing down the shaft. Piping that supplies sealing liquid to the stuffing
box is called seal piping (liquid seal). Seal piping is installed to cool the
shaft and the packing, to lubricate the packing, and to seal the joint
between the shaft and the packing against air leakage. The sealing liquid
either comes from the discharge side of the pump (internally sealed) or
from an external source (externally sealed).
Seal piping leads liquid from the discharge side of the pump or from an
external source to the lantern ring. The lantern ring is a perforated hollow
ring located near the center of the stuffing box. The web of the ring is
perforated so that water can flow in either direction along the shaft to
distribute liquid uniformly around the shaft to provide lubrication and
cooling.
Recirculating lines are installed on some centrifugal pumps to prevent Figure 9-6 — Stuffing
them from overheating and becoming vapor bound when the discharge box.
is entirely shut off.

9-5
A water flinger is fitted on the shaft outboard of the stuffing box glands to prevent leakage from the
stuffing box following along the shaft and entering the bearing housings. The flingers must fit tightly on
the shaft. If the flingers are fitted on the shaft sleeves instead of on the shaft, ensure that no water
leaks under the sleeves.
Mechanical seals eliminate the problem of excessive stuffing box leakage, which causes failure of pump
and motor bearings and motor windings. Mechanical seals are ideal for pumps that operate in closed
systems (such as fuel service and air-conditioning, chilled-water, sonar, radar, and other electronic
cooling systems). They not only conserve the fluid being pumped but also improve system operation.

Operation
Liquid enters the rotating impeller on the suction side of the casing and enters the eye of the impeller
(Figure 9-2). Liquid is thrown out through the opening around the edge of the impeller and against the
side of the casing by centrifugal force. When liquid is thrown out to the edge of the casing, a region of
low pressure (below atmospheric) is created around the center of the impeller; more liquid moves into
the eye to replace the liquid that was thrown out. Liquid moves into the center of the impeller with a
high velocity (speed). Therefore, liquid in the center of the impeller has a low pressure, but it is moving
at a high velocity.
Liquid moving between the blades of the impeller spreads out, which causes the liquid to slow down.
(Its velocity decreases.) At the same time, as the liquid moves closer to the edge of the casing, the
pressure of the liquid increases. This change (from low pressure and high velocity at the center to high
pressure and low velocity at the edge) is caused by the shape of the opening between the impeller
blades. This space has the shape of a diffuser, a device that causes the velocity-pressure relationship
of any fluid that moves through it to change.
A centrifugal pump is considered to be a nonpositive-displacement pump because the volume of liquid
discharged from the pump changes whenever the pressure head changes. The pressure head is the
combined effect of liquid weight, fluid friction, and obstruction to flow. In a centrifugal pump, the force
of the discharge pressure of the pump
must be able to overcome the force of the
pressure head; otherwise, the pump could not
deliver any liquid to a piping system. The
pressure head and the discharge pressure of a
centrifugal pump oppose each other. When the
pressure head increases, the discharge
pressure of the pump must also increase.
Since no energy can be lost, when the
discharge pressure of the pump increases, the
velocity of flow must decrease. On the other
hand, when the pressure head decreases, the
volume of liquid discharged from the pump
increases. As a general rule, a centrifugal pump
is usually located below the liquid being
pumped. (This discussion assumes a constant
impeller speed.)
Figure 9-7 shows that when the pump
discharge is blocked, nothing happens
because the impeller is hollow. A tremendous
buildup in pressure cannot occur because the
Figure 9-7 — Nonpositive-displacement pump.

9-6
passages in the impeller (between the discharge and suction side of the pump) act like a built-in relief
valve. When the discharge pressure and pressure head are equal (as in this case), the impeller is
allowed to rotate (slip) through the liquid in the casing.

NOTE
Centrifugal pumps used for intermittent service may have to
run for long periods of time against a blocked discharge.
Friction between the impeller and the liquid raises the
temperature of the liquid in the casing and causes the
pump to overheat. To prevent this, a small line is connected
between the discharge and the suction piping of the pump.

When a centrifugal pump is started, the vent line must be opened to release entrained air. The open
passage through the impeller of a centrifugal pump also causes another problem. It is possible for liquid
to flow backwards (reverse flow) through the pump. A reverse flow, from the discharge back to the
suction, can happen when the pressure head overcomes the discharge pressure of the pump. A reverse
flow can also occur when the pump is not running and another pump is delivering liquid to the same
piping system. To prevent a reverse flow of liquid through a centrifugal pump, a check valve is usually
installed in the discharge line.

NOTE
Instead of two separate valves, some installations use a
globe stop-check valve.

With a check valve in the discharge line, whenever the pressure above the disk rises above the pressure
below it, the check valve shuts. This prevents liquid from flowing backwards through the pump.

Maintenance
You must observe the operation and safety precautions pertaining to pumps by following the engineering
operational procedure (EOP) subsystem of the engineering operational sequencing system (EOSS)—if
your ship has EOSS. If not, use the Naval Ships’ Technical Manual (NSTM) and/or the instructions
posted on or near each individual pump. You must follow the manufacturer’s technical manual or
maintenance requirement cards (MRCs) for planned maintenance system (PMS)- related work for all
maintenance work. The MRCs list in detail what you have to do for each individual maintenance
requirement.

Mechanical Seals
One type of mechanical seal is shown in Figure 9-8. Spring pressure keeps the rotating seal face snug
against the stationary seal face. The rotating seal and all of the assembly below it are affixed to the
pump shaft. The stationary seal face is held stationary by the seal gland and packing ring. A static seal
is formed between the two seal faces and the sleeve. System pressure within the pump assists the
spring in keeping the rotating seal face tight against the stationary seal face. The type of material used
for the seal faces will depend upon the service of the pump. Most water service pumps use a carbon
material for one of the seal faces and ceramic (tungsten carbide) for the other. When the seals wear
out, they are simply replaced.

9-7
You should replace a mechanical seal whenever the seal is removed from the shaft for any reason or
whenever leakage causes undesirable effects on equipment or surrounding spaces.

Figure 9-8 — Mechanical seal.

You should observe the following precautions when performing maintenance on mechanical seals:
• Do not touch new seals on the sealing face because body acid and grease can cause the seal
face to prematurely pit and fail
• Replace mechanical seals when the seal is removed for any reason, when the leakage rate
exceeds 5 drops per minute, or when leakage causes undesirable effects on equipment or
surrounding spaces
• Position mechanical shaft seals on the shaft by stub or step sleeves. Shaft sleeves are
chamfered (beveled) on outboard ends to provide ease of mechanical seal mounting
• Do not position mechanical shaft seals by using setscrews
Fire pumps and all seawater pumps installed in surface ships are being provided with mechanical shaft
seals with cyclone separators. These separators use centrifugal force to prevent abrasive material (such
as sand in the seawater) from passing between the sealing surfaces of the mechanical seal. There is
an opening at each end of the separator. The opening at the top is for “clean” water, which is directed
though tubing to the mechanical seals in the pump. The high velocity “dirty” water is directed through
the bottom of the separator, back to the inlet piping for the pump. The glands are designed to incorporate
two or more rings of packing if the mechanical shaft seal fails.

Repacking
Lubrication of the pump packing is extremely important. The quickest way to wear out the packing is
to forget to open the water piping to the seals or stuffing boxes. If the packing is allowed to dry out, it
will score the shaft. When operating a centrifugal pump, be sure there is always a slight trickle of water
coming out of the stuffing box or seal.

9-8
How often the packing in a centrifugal pump should be renewed depends on several factors, such as
the type of pump, condition of the shaft sleeve, and hours in use.
To ensure the longest possible service from pump packing, make certain the shaft or sleeve is smooth
when the packing is removed from a gland. Rapid wear of the packing will be caused by roughness of
the shaft sleeve (or shaft where no sleeve is installed). If the shaft is rough, it should be sent to the
machine shop for a finishing cut to smooth the surface. If it is very rough, or has deep ridges in it, it will
have to be renewed. It is absolutely necessary to use the correct packing. When replacing packing, be
sure the packing fits uniformly around the stuffing box. If you have to flatten the packing with a hammer
to make it fit, you are not using the right size.
Pack the box loosely, and set up the packing gland lightly. Allow a liberal leak-off for stuffing boxes that
operate above atmospheric pressure. Next, start the pump. Let it operate for about 30 minutes before
you adjust the packing gland for the desired amount of leak-off. This gives the packing time to run-in
and swell. You may then begin to adjust the packing gland. Tighten the adjusting nuts one flat at a time.
Wait about 30 minutes between adjustments. Be sure to tighten the same amount on both adjusting
nuts. If you pull up the packing gland unevenly (or cocked), it will cause the packing to overheat and
score the shaft sleeves. Once you have the desired leak-off, check it regularly to make certain that
sufficient flow is maintained.

Renewing Shaft Sleeves


In some pumps (usually large pumps), the shaft sleeve is pressed onto the shaft tightly by a hydraulic
press. In this case, the old sleeve must be machined off with a lathe before a new one can be installed.
You must disassemble the pump and take the sleeve to a machine shop, a repair shop, or a naval
shipyard to have this done. On other pumps (usually small pumps), the shaft sleeve may have a snug
slip-on fit, butted up against a shoulder on the shaft and held securely in place with a nut. On these
pumps, new sleeves can be installed by removing the water end casing, impeller, and old shaft sleeves.
New sleeves are carried as repair parts; they can also be made in the machine shop.
To prevent water leakage between the shaft and the sleeve, some sleeves are packed, while others
have an O-ring between the shaft and the abutting shoulder. For detailed information, consult the
appropriate manufacturer’s technical manual or applicable blueprint.

Renewing Wearing Rings


The clearance between the impeller and the casing wearing ring must be maintained as directed by the
manufacturer. When clearances exceed the specified amount, the casing wearing ring must be
replaced. On most ships, this job can be done by the ship’s force, but it requires the complete
disassembly of the pump. All necessary information on disassembly of the unit, dimensions of the
wearing rings, and reassembly of the pump is specified by PMS or can be found in the manufacturer’s
technical manual. Failure to replace the casing wearing ring when the allowable clearance is exceeded
results in a decrease of pump capacity and efficiency. If a pump has to be disassembled because of
some internal trouble, the wearing ring should be checked for clearance. Measure the outside diameter
of the impeller hub with an outside micrometer and the inside diameter of the casing wearing ring with
an inside micrometer; the difference between the two diameters is the actual wearing ring diametric
clearance. By checking the actual wearing ring clearance with the maximum allowable clearance, you
can decide whether to renew the ring before reassembling the pump. The applicable MRCs are a readily
available source of information on proper clearances.
Wearing rings for most small pumps are carried aboard ship as part of the ship’s repair parts allowance.
These may need only a slight amount of machining before they can be installed. For some pumps,
spare rotors are carried aboard ship. The new rotor can be installed and the old rotor sent to

9-9
a repair activity for overhaul. Overhauling a rotor includes renewing the wearing rings, bearings, and
shaft sleeve.

Operating Troubles
You will be responsible for the maintenance of centrifugal pumps. The following is a description of some
of the problems you will have to deal with and the probable causes:
TROUBLE CAUSE
Does not deliver any liquid Insufficient priming
Insufficient speed of the pump
Excessive discharge pressure (such as a
partially closed valve or some other obstruction
in the discharge line)
Excessive suction lift
Clogged impeller passages
Wrong direction of rotation
Clogged suction screen (if used)
Ruptured suction line
Loss of suction pressure
Insufficient capacity Air leakage into the suction line
Insufficient speed of the pump
Excessive suction lift
Clogged impeller passages
Excessive discharge pressure
Mechanical defects (such as worn wearing rings,
impellers, stuffing box packing, or sleeves)
Does not develop enough discharge pressure Insufficient speed of the pump
Air or gas in the liquid being pumped
Mechanical defects (such as worn wearing rings,
impellers, or sleeves and leaking mechanical
seals)
Works for a while and then fails to deliver liquid Air leakage into the suction line
Air leakage in the stuffing boxes
Clogged water seal passages
Insufficient liquid on the suction side
Excessive heat in the liquid being pumped
Takes too much power and the motor overheats Operation of the pump at excess capacity and
insufficient discharge pressure
Misalignment
Bent shaft
Excessively tight stuffing box packing
Worn wearing rings
Other mechanical defects
Vibration Misalignment
Bent shaft
Clogged, eroded, or otherwise unbalanced
impeller
Lack of rigidity in the foundation

9-10
Insufficient suction pressure may also cause vibration, as well as noisy operation and fluctuating
discharge pressure.

Rotary Pumps
Another type of pump you find aboard ship is the rotary pump. A number of types are included in this
classification, among which are the gear pump, the screw pump, and the moving vane pump. Unlike
the centrifugal pump, which we have discussed, the rotary pump is a positive-displacement pump.
This means that for each revolution of the pump, a fixed volume of fluid is moved regardless of the
resistance against which the pump is pushing. As you can see, any blockage in the system could quickly
cause damage to the pump or a rupture of the system. You, as a pump operator, must always be sure
that the system is properly aligned so a complete flow path exists for fluid flow. Also, because of their
positive-displacement feature, rotary pumps require a relief valve to protect the pump and piping
system. The relief valve lifts at a preset pressure and returns the system liquid either to the suction side
of the pump or back to the supply tank or sump.
Rotary pumps are also different from centrifugal pumps in that they are essentially self-priming. As we
saw in our discussion of centrifugal pumps, the pump is located below the liquid being pumped; gravity
creates a static pressure head, which keeps the pump primed. A rotary pump operates within limits with
the pump located above the source of supply.
Rotary pumps are useful for pumping oil and other heavy viscous liquids. In the engine room, rotary
pumps are used for handling lube oil and fuel oil and are suitable for handling liquids over a wide range
of viscosities.
Rotary pumps are designed with very small clearances between rotating parts and stationary parts to
minimize leakage (slippage) from the discharge side back to the suction side. Rotary pumps are
designed to operate at relatively slow speeds to maintain these clearances; operation at higher speeds
causes erosion and excessive wear, which result in increased clearances with a subsequent decrease
in pumping capacity.

Types of Rotary Pumps


There are several types of positive-displacement rotary pumps, including the simple gear, herringbone
gear, helical gear, and vane, lobe, and screw types. Classification of rotary pumps is generally based
on the types of rotating element. The main features of gear, screw, and sliding vane pumps will be
discussed briefly in the following paragraphs.

Gear Pumps
The simple gear pump has two spur gears that mesh together and revolve in opposite directions. One
is the driving gear, and the other is the driven gear. Clearances between the gear teeth (outside
diameter of the gear) and the casing and between the end face and the casing are only a few
thousandths of an inch. As the gears turn, the gears un-mesh and liquid flows into the pockets that are
vacated by the meshing gear teeth. This creates the suction that draws the liquid into the pump. The
liquid is then carried along in the pockets formed by the gear teeth and the casing. On the discharge
side, the liquid is displaced by the meshing of the gears and forced out through the discharge side of
the pump.
Figure 9-9 shows a gear pump located above the tank. The tank must be vented to allow air into the tank
to provide atmospheric pressure on the surface of the liquid. To lower the pressure on the suction side
of the pump, the clearances between the pump parts must be close enough to pump air. When the pump
starts, the air is pumped through the discharge side of the pump and creates the low- pressure area on
the suction side, which allows the atmospheric pressure to force the liquid up the

9-11
pipe to the pump.
To operate
properly, the piping
leading to the pump
must have no leaks
or it will draw in air
and can lose its
prime.
One example of
the use of a gear
pump is in the
LM2500 engine
fuel pump.
However, gear
pumps are not
used extensively
on gas turbine
ships. Figure 9-9 — Gear pump located above the tank.

Screw Pumps
Several different types of screw pumps exist.
The differences between the various types are
the number of intermeshing screws and the pitch
of the screws. Figure 9-10 shows a double-
screw, low-pitch pump. Screw pumps are used
aboard ship to pump fuel and lube oil and to
supply pressure to the hydraulic system. In the
double-screw pump, one rotor is driven by the
drive shaft and the other by a set of timing gears.
In the triple-screw pump, a central rotor meshes
with two idler rotors.
In the screw pump, liquid is trapped and forced
through the pump by the action of rotating
screws. As the rotor turns, the liquid flows in
between the threads at the outer end of each
pair of screws. The threads carry the liquid along
within the housing to the center of the pump
where it is discharged.
Most screw pumps are now equipped with
mechanical seals. If the mechanical seal fails, Figure 9-10 — Double-screw, low-pitch
the stuffing box has the capability of accepting pump.
two rings of conventional packing for
emergency use.

9-12
Sliding Vane Pumps
The sliding-vane pump (Figure 9-11) has a cylindrically
bored housing with a suction inlet on one side and a
discharge outlet on the other side. A rotor (smaller in
diameter than the cylinder) is driven about an axis that is
placed above the center line of the cylinder to provide
minimum clearance between the rotor and cylinder at the
top and maximum clearance at the bottom.
The rotor carries vanes (which move in and out as the rotor
rotates) to maintain sealed spaces between the rotor and
the cylinder wall. The vanes trap liquid on the suction side
and carry it to the discharge side, where contraction of the
space expels liquid through the discharge line. The vanes
slide on slots in the rotor. Vane pumps are used for lube oil
service and transfer, tank stripping, bilge, aircraft fueling
and defueling and, in general, for handling lighter viscous Figure 9-11 — Sliding vane pump.
liquids.

Jet Pumps
The pumps discussed so far in this chapter have had
a variety of moving parts. One type of pump you find
in the engine room is the jet pump, usually called an
eductor. Figure 9-12 shows an eductor, which has no
moving parts. These pumps are used for pumping
large quantities of water overboard in such
applications as pumping bilges and dewatering
compartments. As an engineer, you will think of
eductors as part of the main and secondary drainage
system; you will also become familiar with them as
part of the ship’s damage control equipment.
Eductors use a high-velocity jet of seawater to lower
the pressure in the chamber around the converging
nozzle. Seawater is supplied to the converging nozzle
at a relatively low velocity and exits the nozzle at a
high velocity. As the seawater leaves the nozzle and
passes through the chamber, air becomes entrained
in the jet stream and is pumped out of the chamber.
Pressure in the chamber decreases, allowing
atmospheric pressure to push the surrounding water
into the chamber and mix with the jet stream. The
diverging nozzle allows the velocity of the fluid to
decrease and the pressure to increase; the discharge
pressure is then established.
Figure 9-12 — Portable eductor.

9-13
Figure 9-13 is an example of a typical shipboard
eductor system. A simple jet pump consists of a
jet supply line, a jet or nozzle, a suction line, a
suction chamber, a diffuser, and a discharge
line. In a jet pump, pumping action is created as
a fluid (water, steam, or air) passes at a high
pressure and velocity through a nozzle and into
a chamber that has an inlet and outlet opening.
The operating principle of a jet pump is as
follows: Upon starting up, the rapidly moving jet
fluid pushes on and gives sufficient motion to
the air (or whatever substance may be in the
suction chamber) to carry it out through the
discharge line. Displacement of the air from the
suction chamber creates a partial vacuum within
the suction chamber, causing fluid to flow
through the suction line. The fluid entering the
chamber from the suction line is picked up by the
high-velocity fluid, thus providing continuous
pumping action.
Figure 9-13 — Simple jet pump.
ALIGNMENT OF SHAFT AND COUPLING
When you install or assemble pumps driven by electric motors, make sure the unit is aligned properly.
If the shaft is misaligned, you must realign the unit to prevent shaft breakage and damage to bearings,
pump casing wearing rings, and throat bushings. Always check the shaft alignment with all the piping
in place.
Some driving units are connected to the pump by a flexible coupling. A flexible coupling (Figure 9-14)
is intended to take care of only a slight misalignment. Misalignment should never exceed the amount
specified by the pump manufacturer. If the misalignment is excessive, the coupling parts are subjected
to
severe
punishment,
necessitating
frequent
replacement of
pins, bushings,
and bearings. It
is absolutely
necessary to
have the rotating
shafts of the
driver and driven
units in proper
alignment.

Figure 9-14 — Flexible couplings.

9-14
You should check the shaft alignment when the pump is opened for repair or maintenance, or if a
noticeable vibration occurs. You must realign the unit if the shafts are out of line or inclined at an angle
to each other. Whenever practicable, check the alignment with all piping in place and with the adjacent
tanks and piping filled.
When the driving unit is connected to the pump by a flange coupling, the shafting may require frequent
realignment, which may be indicated by high temperatures, noises, and worn bearings or bushings.
Wedges, or shims, are sometimes placed under the bases of both the driven and driving units (Figure
9-15, view A) for ease in alignment when the machinery is installed. When the wedges or other packing
have been adjusted so the outside diameters and faces of the coupling flanges run true as they are
manually revolved, the chocks are fastened, the units are securely bolted to the foundation, and the
coupling flanges are bolted together.
The faces of the coupling flanges should be checked at 90-degree intervals. This method is shown in
Figure 9-15, view B. Find the distances between the faces at point a, point b (on the opposite side), point
c, and point d (opposite point c). This action will show whether the coupling faces are parallel to each
other. If they are not parallel to each other, adjust the driving unit or the pump with shims until the
couplings check true. While measuring the distances, you must keep the outside diameters of the
coupling flanges in line. To do this, place the scale across the two flanges, as shown in Figure 9-15, view
C. If the flanges do not line up, raise or lower one of the units with shims, or shift them sideways.
The procedure for using a thickness gauge to check alignments is similar to that for a scale. When the
outside diameters of the coupling flanges are not the same, use a scale on the surface of the larger
flange, and then use a thickness gauge between the surface of the smaller flange and the edge of the
scale. When the space is narrow, check the distance between the coupling flanges with a thickness
gauge, as shown in Figure 9-15, view D. Check wider spaces with a piece of square key stock and a
thickness gauge.

Figure 9-15 — Coupling alignment.

9-15
CONSTANT-PRESSURE PUMP GOVERNORS
A governor is a feedback device that is used to
provide automatic control of speed, pressure, or
temperature. A constant-pressure pump governor
maintains a constant discharge pressure,
regardless of pump capacity or output. Most
constant-pressure pump governors used in the
Navy control steam-driven pumps, both rotary and
centrifugal types.
The constant-pressure pump governor (sometimes
referred to as pressure-regulating) consists
essentially of an automatic throttling valve installed
in the steam supply line to the pump’s driving unit.
A pipeline connects the governor to the pump’s
discharge line. Variations in discharge pressure, or
in pressure differential, actuate the governor,
causing it to regulate the pump speed by varying the
flow of steam to the driving unit.
A constant-pressure pump governor for a lubricating
oil service pump is shown in Figure 9-16. The
governors used on fuel oil service pumps and on Figure 9-16 — Constant-pressure governor
main feed pumps are of the same type. The size of for main feed pump.
the upper diaphragm and the amount of spring
tension vary on governors used for different services.

VALVES
A valve is any device used to control fluids in a closed system. In this section we will discuss valve
construction and the most common types of valves you will use in the day-to-day operation and
maintenance of the various shipboard engineering systems. Valves are typed or classified according
to their use in a system.
Every piping system must have some means to control the amount and direction of the flow of a liquid
or a gas through the lines. This is accomplished by the use of valves, which can be opened or closed
as required. All valves can be grouped in two general classifications: (1) manually operated valves and
(2) automatic valves.
Manually operated valves include all valves that are adjusted by hand. Automatic valves include check
valves, thermostatic valves, and pressure-regulating valves. This section contains general information
only. You should refer to the appropriate Naval Sea Systems Command (NAVSEA) valve manuals if
you should require more specific information.

Valve Construction
Valves are usually made of bronze, brass, cast or malleable iron, or steel. Steel valves are either cast
or forged and are made of either plain steel or alloy steel. Alloy steel valves are used in high- pressure,
high-temperature systems; the disks and seats (internal sealing surfaces) of these valves are usually
surfaced with a chromium cobalt alloy known as Stellite, which is extremely hard.
Brass and bronze valves are never used in systems where temperatures exceed 550 °F. Steel valves
are used for all services above 550 °F and in lower temperature systems where internal or external

9-16
conditions of high pressure, vibration, or shock would be too severe for valves made of brass or bronze.
Bronze valves are used almost exclusively in systems that carry saltwater. The seats and disks of these
valves are usually made of Monel, a metal that has excellent corrosion- and erosion- resistant qualities.
Most submarine seawater valves are made of an alloy of 70 percent copper to 30 percent nickel (70/30).

Valve Types
Although many different types of valves are used to
control the flow of fluids, the basic valve types can be
divided into two general groups: stop valves and
check valves.
Besides the basic types of valves, many special
valves, which cannot really be classified as either stop
valves or check valves, are found in the engineering
spaces. Many of these valves serve to control the
pressure of fluids and are known as pressure-control
valves. Other valves are identified by names that
indicate their general function, such as thermostatic
recirculating valves. The following sections deal first
with the basic types of stop valves and check valves,
then with some of the more complicated special
valves.
Figure 9-17 — Types of globe valve
Stop Valves bodies.
Stop valves are used to shut off or, in some cases,
partially shut off the flow of fluid. Stop valves are
controlled by the movement of the valve stem.
Stop valves can be divided into four general
categories: globe, gate, butterfly, and ball valves.
Plug valves and needle valves may also be
considered stop valves.

Globe Valves
Globe valves are probably the most common valves
in existence. The globe valve derives its name from
the globular shape of the valve body. However,
positive identification of a globe valve must be made
internally because other valve types may have
globular appearing bodies. Globe valve inlet and
outlet openings are arranged in several ways to suit
varying requirements of flow. Figure 9- 17 shows the
common types of globe valve bodies: straight-flow,
angle-flow, and cross-flow. A cutaway view of a
straight-flow globe valve is shown in Figure 9-18.
Figure 9-18 — Cutaway view of a straight-
flow globe valve.

9-17
Gate Valves
Gate valves are used when a straight-line flow of fluid and minimum restriction is desired. Gate valves
are so named because the part that either stops or allows flow through the valve acts somewhat like
the opening or closing of a gate and is called, appropriately, the gate. The gate is usually wedge shaped.
When the valve is wide open, the gate is fully drawn up into the valve, leaving an opening for flow
through the valve the same size as the pipe in which the valve is installed. Therefore, there is little
pressure drop or flow restriction through the valve. Gate valves are not suitable for throttling purposes
since the control of flow would be
difficult due to valve design and since the flow
of fluid slapping against a partially open gate
can cause extensive damage to the valve.
Except as specifically authorized, gate valves
should not be used for throttling.
Gate valves are classified as either rising-stem
or nonrising-stem valves (Figure 9-19). On the
nonrising-stem gate valve, the stem is threaded
on the lower end into the gate. As the handwheel
on the stem is rotated, the gate travels up or
down the stem on the threads, while the stem
remains vertically stationary.
This type of valve almost always has a pointer-
type indicator threaded onto the upper end of
the stem to indicate valve position. In the design
of the rising-stem valve, the stem is attached to
the gate. The gate and stem rise and sink Figure 9-19 — Gate stop valve (nonrising-
together as the valve is operated. stem).
Gate valves used in steam systems have flexible gates. The
reason for using a flexible gate is to prevent binding of the gate
within the valve when the valve is in the closed position. When
steam lines are heated, they will expand, causing some
distortion of valve bodies. If a solid gate fits snugly between the
seat of a valve in a cold steam system, when the system is
heated and pipes elongate, the seats will compress against the
gate, wedging the gate between them and clamping the valve
shut. This problem is overcome by use of a flexible gate (two
circular plates attached to each other with a flexible hub in the
middle). This design allows the gate to flex as the valve seat
compresses it, thereby preventing clamping.

Butterfly Valves
The butterfly valve, one type of which is shown in Figure 9- 20,
may be used in a variety of systems aboard ship. These valves
can be used effectively in freshwater, saltwater, JP-5, F-76
(naval distillate), lube oil, and chill water systems aboard ship.
The butterfly valve is light in weight, relatively small, relatively
quick-acting, provides positive shut-off, and can be used for
throttling.
Figure 9-20 — Butterfly valve.

9-18
The butterfly valve has a body, a resilient seat, a butterfly disk, a stem, packing, a notched positioning
plate, and a handle. The resilient seat is under compression when it is mounted in the valve body, thus
making a seal around the periphery of the disk and both upper and lower points where the stem passes
through the seat. Packing is provided to form a positive seal around the stem for added protection in
case the seal formed by the seat should become damaged. To close or open a butterfly valve, turn the
handle only one quarter turn to rotate the disk 90 degrees. Some larger butterfly valves may have a
handwheel that operates through a gearing arrangement to operate the valve. This method is used
especially where space limitation prevents use of a long handle.
A newer, high-performance butterfly valve is shown in
Figure 9-21. This improved design has higher pressure
capabilities and allows for a full range of throttling
positions not offered in the older design of butterfly
valve shown in Figure 9-20. The newer design of
butterfly valve has been introduced into the fleet and is
gradually replacing the older design.
Unlike the older style of butterfly valve, the new style
has a removable retaining ring that holds the seat in
place. To change the seat, all you must do is remove
the retaining ring, remove the old seat, place a new
seat into its groove, and reinstall the retainer ring.
Butterfly valves are relatively easy to maintain. The
resilient seat is held in place by mechanical means,
and neither bonding nor cementing is necessary.
Because the seat is replaceable, the valve seat does
not require lapping, grinding, or machine work.
Figure 9-21 — Cutaway view of a
Ball Valves high-performance butterfly valve.
Ball valves, as the name implies, are stop valves
that use a ball to stop or start the flow of fluid. The
ball (Figure 9-22) performs the same function as
the disk in the globe valve. When the valve handle
is operated to open the valve, the ball rotates to a
point where the hole through the ball is in line with
the valve body inlet and outlet. When the valve is
shut, which requires only a 90-degree rotation of
the handwheel for most valves, the ball is rotated
so the hole is perpendicular to the flow openings of
the valve body, and flow is stopped.
Most ball valves are of the quick-acting type
(requiring only a 90-degree turn to operate the valve
either completely open or closed), but many are
planetary gear operated. This type of gearing allows
the use of a relatively small handwheel and
operating force to operate a fairly large valve. The Figure 9-22 — Ball valve.
gearing does, however, increase the operating
time for the valve. Some ball valves contain a swing check located within the ball to give the valve a
check valve feature. Ball valves are normally found in the following systems aboard ship: seawater,
sanitary, trim and drain, air, hydraulic, and oil transfer.

9-19
Check Valves
Check valves permit liquids to flow through a line in one direction only; for example, they are used in
drain lines where it is important that there is no backflow. Considerable care must be taken to see that
valves are installed properly. Most of them have an arrow, or the word “inlet,” cast on the valve body
to indicate direction of flow. If not, you must check closely to make sure the flow of the liquid in the
system operates the valve in the proper manner.
The port in a check valve may be closed by a disk, a ball, or a plunger. The valve opens automatically
when the pressure on the inlet side is greater than that on the outlet side. They are made with threaded,
flanged, or union faces, with screwed or bolted caps, and for specific pressure ranges.
The disk of a swing-check valve (Figure 9-23)
is raised as soon as the pressure in the line
below the disk is of sufficient force. While the
disk is raised, continuous flow takes place. If
for any reason the flow is reversed or if back
pressure builds up, this opposing pressure
forces the disk to seat, which, in turn, stops the
flow. Swing-check valves are used in
horizontal lines and have a small amount of
resistance to flow.
The operation of a lift-check valve (Figure 9-
24) is basically the same as that of the swing-
check valve. The difference is the valve disk
moves in an up and down direction instead of
through an arc. Lift-check valves are used in
lines where reversal of flow and pressures are
changing frequently. This valve does not chatter
or slam as the swing check valve does, but it Figure 9-23 — Swing-check valve.
does cause some restriction of flow.

Stop-Check Valve
As we have seen, most valves can be classified
as being either stop valves or check valves.
Some valves, however, function either as stop
valves or as check valves—depending on the
position of the valve stem. These valves are
known as stop-check valves.
The cross section of two stop-check valves is
shown in Figure 9-25. As you can see, this type
of valve looks much like a lift-check valve. The
valve stem is long enough so when it is screwed
all the way down, it holds the disk firmly against
the seat, thereby preventing the flow of any fluid.
In this position, the valve acts as a stop valve.
When the stem is raised, the disk can then be
opened by pressure on the inlet side. In this Figure 9-24 — Lift-check valve.
position, the valve acts as a check valve and
allows the flow of fluid in one

9-20
direction only. The amount of fluid
allowed to pass through is
regulated by the opening. The
opening is adjusted by the stem.

Special-Purpose Valves
There are many types of automatic
pressure-control valves. Some of
them merely provide an escape for
pressures exceeding the normal
pressure; some provide only for the
reduction of pressure; and some
provide for the regulation of
pressure.

Relief Valves
Relief valves are automatic valves
used on system lines and
equipment to prevent
overpressurization. Most relief
valves simply lift (open) at a preset Figure 9-25 — Stop-check valve.
pressure and reset (shut) when the
pressure drops only slightly below the lifting
pressure. Figure 9-26 shows a relief valve of this
type. System pressure simply acts under the valve
disk at the inlet of the valve. When system
pressure exceeds the force exerted by the valve
spring, the valve disk lifts off its seat, allowing
some of the system fluid to escape through the
valve outlet until system pressure is reduced to
just below the relief set point of the valve. The
spring then reseats the valve. An operating lever
is provided to allow manual cycling of the relief
valve or to gag it open for certain tests. Virtually
all relief valves are provided with some type of
device to allow manual cycling.
Other types of relief valves are the high-pressure
air safety relief valve and the bleed air surge relief
valve. Both of these types of valves are designed
to open completely at a specified lift pressure and
to remain open until a specific reset pressure is
reached—at which time they shut. Many different Figure 9-26 — Typical relief valve.
designs of these valves are used, but the same
result is achieved.

Spring-Loaded Reducing Valves


One type of spring-loaded reducing valve is shown in Figure 9-27. These valves are used in a wide
variety of applications. Low-pressure air reducers, auxiliary machinery cooling-water reducing stations,
and some reduced-steam system reducers are of this type. The spring-loaded pressure-

9-21
reducing valve is commonly used in pneumatic
systems. It is often referred to as a pressure
regulator. The valve simply uses spring pressure
against a diaphragm to open the valve. On the
bottom of the diaphragm, the outlet pressure (the
pressure in the reduced-pressure system) of the
valve forces the disk upward to shut the valve.
When the outlet pressure drops below the set
point of the valve, spring pressure overcomes the
outlet pressure and forces the valve stem
downward, opening the valve. As outlet pressure
increases, approaching the desired value, the
pressure under the diaphragm begins to
overcome spring pressure. This forces the valve
stem upward, shutting the valve.
Downstream pressure can be adjusted by
removing the valve cap and turning the adjusting
screw, which varies the spring pressure against
the diaphragm. This particular spring-loaded
valve will fail in the open position in the case of a
diaphragm rupture. Figure 9-27 — Spring-loaded pressure-
reducing valve.
Remote-Operating Valves
Remote-operating gear is installed to provide a means of operating certain valves from distant stations.
Remote-operating gear may be mechanical, hydraulic, pneumatic, or electric.
Some remote-operating gear for valves is used in the normal operation of valves. For example, the
main drain system manual valves are opened and closed by a reach rod or a series of reach rods and
gears. Reach rods may be used to operate engine-room valves in instances where the valves are
difficult to reach from the operating stations.
Other remote-operating gear is installed as emergency equipment. Some of the main drain and almost
all of the secondary drain system valves are equipped with remote-operating gears. You can operate
these valves locally, or in an emergency, you can operate them from remote stations.
Remote-operating gear also includes a valve position indicator to show whether the valve is open or
closed.

Pressure-Reducing Valves
Pressure-reducing valves are automatic valves that provide a steady pressure into a system that is at
a lower pressure than the supply system. Reducing valves of one type or another are found, for
example, in firemain, seawater, and other systems. A reducing valve can normally be set for any
desired downstream pressure within the design limits of the valve. Once the valve is set, the reduced
pressure will be maintained regardless of changes in the supply pressure (as long as the supply
pressure is at least as high as the reduced pressure desired) and regardless of the amount of reduced
pressure fluid that is used.
Various designs of pressure-reducing valves are in use. Two of the types most commonly found on gas
turbine ships are the spring-loaded reducing valve (already discussed) and the air-pilot-operated
diaphragm reducing valve.

9-22
Air-Pilot-Operated Diaphragm Control Valves
Air-pilot-operated diaphragm control valves are used
extensively on naval ships. The valves and pilots are
available in several designs to meet different
requirements. They may be used to reduce pressure,
to increase pressure, to serve as unloading valves, or
to provide continuous regulation of pressure. Valves
and pilots of very similar design can also be used for
other services, such as liquid-level control and
temperature control.
The air-operated control pilot may be either direct acting
or reverse acting. A direct-acting, air-operated control
pilot is shown in Figure 9-28. In this type of pilot, the
controlled pressure—that is, the pressure from the
discharge side of the diaphragm control valve—acts on
top of a diaphragm in the control pilot. This pressure is
balanced by the pressure exerted by the pilot adjusting
spring. If the controlled pressure increases and
overcomes the pressure exerted by the pilot adjusting
spring, the pilot valve stem is forced downward. This
action causes the pilot valve to open, thereby increasing
the amount of operating air pressure going from the pilot
to the diaphragm control valve. A reverse-acting pilot has
a lever that reverses the pilot action. In a reverse-acting
pilot, therefore, an increase in controlled pressure
produces a decrease in Figure 9-28 — Air-operated control
operating air pressure. pilot.
In the diaphragm control valve, operating air from the pilot acts on the valve diaphragm. The
superstructure, which contains the diaphragm, is direct acting in some valves and reverse acting in
others. If the superstructure is direct-acting, the operating air pressure from the control pilot is applied
to the top of the valve diaphragm. If the superstructure is reverse-acting, the operating air pressure from
the pilot is applied to the underside of the valve diaphragm.
A very simple type of direct-acting diaphragm control valve is shown in Figure 9-29. The operating air
pressure from the control pilot is applied to the top of the valve diaphragm. The valve in Figure 9-29,
view A, is a downward-seating valve. Any increase in operating air pressure pushes the valve stem
downward. This tends to close the valve.
Now look at Figure 9-29, view B; this is also a direct-acting valve. The operating air pressure from the
control pilot is applied to the top of the valve diaphragm. But the valve is more complicated than the
one shown in Figure 9-29, view A. The valve in Figure 9-29, view B, is an upward-seating valve rather
than a downward-seating valve. Therefore, any increase in operating air pressure from the control pilot
tends to open this valve rather than to close it.
As you have seen, the air-operated control pilot may be either direct acting or reverse acting. The
superstructure of the diaphragm control valve may be either direct acting or reverse acting. And, the
diaphragm control valve may be either upward seating or downward seating. These three factors, as
well as the purpose of the installation, determine how the diaphragm control valve and its air-operated
control pilot are installed in relation to each other.

9-23
Figure 9-29 — Diaphragm control valves.

To see how these


factors are related,
let us consider an
installation: A
diaphragm control
valve and its air-
operated control pilot
are used to supply
reduced steam
pressure (Figure 9-
30). We will assume
that the service
requirements
indicate the need for
a direct-acting,
upward-seating,
diaphragm control
valve. Can you figure
out which kind of a
control pilot— direct-
acting or reverse-
acting— should be
used in this
installation?
Figure 9-30 — Arrangement of control pilot and diagram control valve
for supplying reduced steam pressure.
9-24
Let us try it first with a direct-acting control pilot. The controlled pressure (discharge pressure from the
diaphragm control valve) increases. When that happens, increased pressure is applied to the
diaphragm of the direct-acting control pilot. The valve stem is pushed downward and the valve in the
control pilot is opened. This sends an increased amount of operating air pressure from the control pilot
to the top of the diaphragm control valve. The increased operating air pressure acting on the diaphragm
of the valve pushes the stem downward. Since this is an upward-seating valve, this action opens the
diaphragm control valve still wider. Obviously, this will not work—for this application, an increase in
controlled pressure must result in a decrease in operating air pressure. Therefore, we made a mistake
in choosing the direct-acting control pilot. For this particular pressure-reducing application, we should
choose a reverse-acting control pilot.
You will probably not need to decide which type of control pilot and diaphragm control valve are needed
in any particular installation. But you must know how and why they are selected so that you will not
make mistakes in repairing or replacing these units.

Priority Valves
In systems with two or more circuits, it is sometimes necessary to have some means of supplying all
available fluid to one particular circuit in case of a pressure drop in the system. A priority valve is often
incorporated in the system to ensure a supply of fluid to the critical/vital circuit. The components of the
system are arranged so the fluid to operate each circuit, except the one critical/vital circuit, must flow
through the priority valve. A priority valve may also be used within a subsystem containing two or more
actuating units to ensure a supply of fluid to one of the actuating units. In this case, the priority valve is
incorporated in the subsystem in such a location that the fluid to each actuating unit, except the
critical/vital unit, must flow through the valve.
Figure 9-31 shows one type of priority valve. Figure
9-31, view A, shows the valve in the priority-flow
position; that is, the fluid must flow through the
valve in the direction shown by the arrows to get to
the noncritical/vital circuits or actuating units. With
no fluid pressure in the valve, spring tension forces
the piston against the stop and the poppet seats
against the hole in the center of the piston. As fluid
pressure increases, the spring compresses and the
piston moves to the right. The poppet follows the
piston, sealing the hole in the center of the piston
until the preset pressure is reached. (The preset
pressure depends upon the requirements of the
system and is set by the manufacturer.) Assume
that the critical/vital circuit or actuating unit requires
1,500 pounds per square inch (psi). When the
pressure in the valve reaches 1,500 psi, the poppet
reaches the end of its travel. As the pressure
increases, the piston continues to move to the Figure 9-31 — Priority valve.
right, which unseats the poppet and allows flow
through the valve, as shown in Figure 9-31, view A. If the pressure drops below 1,500 psi, the
compressed spring forces the piston to the left, the poppet seats, and flow through the valve stops.
Figure 9-31, view B, shows the priority valve in the free-flow position. The flow of fluid moves the
poppet to the left, the poppet spring compresses, and the poppet unseats. This allows free flow of fluid
through the valve.

9-25
Valve Manifolds
Sometimes suction must be taken from one of many sources and discharged to another unit or units
of either the same or another group. A valve manifold is used for this type of operation. An example of
such a manifold (Figure 9-32) is the fuel oil filling and transfer system where provision must be made
for the transfer of oil from any tank to any other tank, to the service system, or to another ship. If, for
example, the purpose is to transfer oil from tank No. 1 to tank No. 4, the discharge valve for tank No.
4 and the suction valve from tank No. 1 are opened, and all other valves are closed. Fuel oil can now
flow from tank No. 1, through the suction line, through the pump, through the discharge valve, and into
tank No. 4. The manifold suction valves are often of the stop-check type to prevent draining of pumps
when they are stopped.

Figure 9-32 — Valve manifold showing cutaway view of the valves and typical
combination of suction and discharge valves.
9-26
Valve Handwheel Identification and Color Coding
Valves are identified by markings inscribed on the rims of the handwheels, by a circular label plate
secured by the handwheel nut, or by label plates attached to the ship’s structure or to the adjacent
piping.
Piping system valve handwheels and operating levers are marked for training and casualty control
purposes with a standardized color code. Color code identification is in conformance with the color
scheme of Table 9-1. Implementation of this color scheme provides uniformity among all naval surface
ships and shore-based training facilities.
Table 9-1 — Valve Handwheel Color Code
FLUID VALVE HANDWHEEL & OPERATING LEVER
STEAM WHITE

POTABLE-WATER DARK BLUE

NITROGEN LIGHT GRAY

HP AIR DARK GRAY

LP AIR TAN

OXYGEN LIGHT GREEN

SALTWATER DARK GREEN

JP-5 PURPLE

FUEL OIL YELLOW

LUBE OIL STRIPPED YELLOW/BLACK

FIRE PLUGS RED

FOAM DISCHARGE STRIPED RED/GREEN

GASOLINE YELLOW

FEEDWATER LIGHT BLUE

HYDRAULIC ORANGE

HYDROGEN CHARTREUSE

HELIUM BUFF

HELIUM/OXYGEN STRIPED BUFF/GREEN

SEWAGE GOLD

9-27
Maintenance
Preventive maintenance is the best way to extend the life of valves and fittings. Always refer to the
applicable PMS procedures and the Navy Standard Valve Technical Manual. When making repairs
on more sophisticated valve types, use the available manufacturer’s technical manuals. As soon as
you observe a leak, determine the cause, and then apply the proper corrective maintenance.
Maintenance may be as simple as tightening a packing nut or gland. A leaking flange joint may need
only to have the bolts tightened or to have a new gasket or O-ring inserted. Dirt and scale, if allowed
to collect, will cause leakage. Loose hangers permit sections of a line to sag, and the weight of the
pipe and the fluid in these sagging sections may strain joints to the point of leakage.
Whenever you are going to install a valve, be sure you know the function the valve is going to perform—
that is, whether it must start flow, stop flow, regulate flow, regulate pressure, or prevent backflow.
Inspect the valve body for the information that is stamped upon it by the manufacturer: type of system
(oil, water, and gas), operating pressure, direction of flow, and other information.
You should also know the operating characteristics of the valve, the metal from which it is made, and
the type of end connection with which it is fitted. Operating characteristics and the material are factors
that affect the length and kind of service that a valve will give; end connections indicate whether or not
a particular valve is suited to the installation.
When you install valves, ensure they are readily accessible and allow enough headroom for full
operation. Install valves with stems pointing upward if possible. A stem position between straight up
and horizontal is acceptable, but avoid the inverted position (stem pointing downward). If the valve is
installed with the stem pointing downward, sediment will collect in the bonnet and score the stem.
Also, in a line that is subject to freezing temperatures, liquid that is trapped in the valve bonnet may
freeze and rupture it.
Since you can install a globe valve with pressure either above the disk or below the disk (depending
on which method will be best for the operation, protection, maintenance, and repair of the machinery
served by the system), you should use caution. The question of what would happen if the disk became
detached from the stem is a major consideration in determining whether pressure should be above the
disk or below it. If you are required to install a globe valve, be SURE to check the blueprints for the
system to see which way the valve must be installed. Very serious casualties can result if a valve is
installed with pressure above the disk when it should be below the disk, or below the disk when it
should be above.
Valves that have been in constant service for a long time will eventually require gland tightening,
repacking, or a complete overhaul of all parts. If you know that a valve is not doing the job for which it
was intended, dismantle the valve and inspect all parts. You must repair or replace all defective parts.
The repair of globe valves (other than routine renewal of packing) is limited to refinishing the seat and/or
disk surface. When doing this work, you should observe the following precautions:
When refinishing the valve seat, do not remove more material than is necessary. You can finish valves
that do not have replaceable valve seats only a limited number of times.
Before doing any repair to the seat and disk of a globe valve, check the valve disk to make certain it is
secured rigidly to and is square on the valve stem. Also, check to be sure that the stem is straight. If
the stem is not straight, the valve disk cannot seat properly.

Spotting-In Valves
The method used to visually determine whether the seat and the disk of a valve make good contact with
each other is called spotting-in. To spot-in a valve seat, first apply a thin coating of Prussian blue evenly
over the entire machined face surface of the disk. Then, insert the disk into the valve and

9-28
rotate it one-quarter turn, using light downward
pressure. The Prussian blue will adhere to the
valve seat at those points where the disk makes
contact. Figure 9-33 shows the appearance of a
correct seat when it is spotted-in. It also shows the
appearance of various kinds of imperfect seats.
After you have noted the condition of the seat
surface, wipe all the Prussian blue off the disk
face surface. Apply a thin, even coat of Prussian
blue to the contact face of the seat, place the disk
on the valve seat again, and rotate the disk one-
quarter turn. Examine the resulting blue ring on
the valve disk. The ring should be unbroken and
of uniform width. If the blue ring is broken in any
way, the disk is not a proper fit.

Grinding-In Valves
Figure 9-33 — Examples of spotted-in valve
The manual process used to remove small seats.
irregularities by grinding together the contact
surfaces of the seat and disk is called grinding-in. Grinding-in should not be confused with refacing
processes in which lathes, valve reseating machines, or power grinders are used to recondition the
seating surfaces.
To grind-in a valve, first apply a light coating of grinding compound to the face of the disk. Then, insert
the disk into the valve and rotate the disk back and forth about one-quarter turn; shift the disk- seat
relationship from time to time so the disk will be moved gradually, in increments, through several
rotations. During the grinding process, the grinding compound will gradually be displaced from between
the seat and disk surfaces; therefore, you must stop every minute or so to replenish the compound.
When you do this, wipe both the seat and the disk clean before applying the new compound to the disk
face.
When you are satisfied that the irregularities have been removed, spot-in the disk to the seat in the
manner previously described.
Grinding-in is also used to follow up all machining work on valve seats or disks. When the valve seat
and disk are first spotted-in after they have been machined, the seat contact will be very narrow and
will be located close to the bore. Grinding-in, using finer and finer compounds as the work progresses,
causes the seat contact to become broader. The contact area should be a perfect ring covering about
one-third of the seating surface.
Be careful to avoid overgrinding a valve seat or disk. Overgrinding will produce a groove in the seating
surface of the disk; it will also round off the straight, angular surface of the disk. Machining is the only
process by which overgrinding can be corrected.

Lapping Valves
When a valve seat contains irregularities that are slightly larger than can be satisfactorily removed by
grinding-in, remove the irregularities by lapping. Use a cast-iron tool of exactly the same size and shape
as the valve disk to true the valve seat surface. A lapping tool is shown in Figure 9-34.
Observe the following operating instructions when you use a lapping tool:
• Do not bear down heavily on the handle of the lapping tool

9-29
• Do not bear sideways on the handle of the lapping tool
• Rotate the lapping tool so that the lap will gradually and uniformly
cover the entire seat
• Keep a check on the working surface of the lapping tool. If a groove
develops, have the tool refaced
• Always use clean compound for lapping
• Replace the compound frequently
• Spread the compound evenly and lightly
• Do not lap more than is necessary to produce a smooth, even seat
• Always use a fine grinding compound to finish the lapping job
• Upon completion of the lapping job, spot-in and grind-in the disk to
the seat
Use only approved abrasive compounds to recondition valve seats and
disks. Compounds for lapping and grinding valve disks and seats come in
various grades. Use a course grade compound when you find extensive
corrosion or deep cuts on the disks and seats. Use a compound of medium
grade to follow up the coarse grade and to start the reconditioning process
Figure 9-34 — Lapping
on valves that are not too severely damaged. Use a fine grade compound
tool.
when the reconditioning process nears completion. Use a microscopic-fine
grade for finish lapping and for all grinding-in.

Refacing Valves
Badly scored valve seats must be refaced in a lathe, with a power grinder, or with a valve reseating
machine. However, the lathe, rather than the reseating machine, should be used for refacing all valve
disks and all hard-surfaced valve seats. Work that must be done on a lathe or with a power grinder
should be turned over to shop personnel.

Repacking Valves
If the stem and packing of a valve are in good condition, you can normally stop packing gland leaks by
tightening up on the packing. You must be careful, however, to avoid excessive thread engagement of
the packing gland studs (if used) and to avoid tightening old, hardened packing, which will cause the
valve to seize. Subsequent operation of such a valve may score or bend the stem.
Coils, rings, and corrugated ribbon are the common forms of packing used in valves. The form of
packing to be used in repacking a particular valve will depend on the valve size, application, and type.
Packing materials will be discussed in more detail later in this chapter.

Steam Traps
Steam traps are installed in steam lines to drain condensate from the lines without allowing the
escape of steam. There are many different designs of steam traps; some are suitable for high-
pressure use and others for low-pressure use.

Types of Steam Traps


Some types of steam traps that are used in the Navy are the mechanical steam traps, bimetallic
steam traps, and orifice-type steam traps.

9-30
Mechanical Steam Traps
Mechanical steam traps may be of the ball-float
or bucket type.

Ball-Float Trap
In a ball-float steam trap (Figure 9-35), the valve
of the trap is connected to the float in such a way
that the valve opens when the float rises. When
the trap is in operation, the steam and any water
that may be mixed with it flow into the float
chamber. As the water level rises, the float lifts,
thereby lifting the valve plug and opening the
valve. The condensate drains out and the float
moves down to a lower position, closing the valve.
The condensate that passes out of the trap
returns to the feed system.

Bucket-Type Trap
Figure 9-35 — Ball-float steam trap.
In a bucket-type steam trap (Figure 9-36) the
bucket floats when condensate enters the trap
body. The valve is connected to the bucket in such
a way that the valve closes as the bucket rises. As
condensate continues to flow into the trap body,
the valve remains closed until the bucket is full.
When the bucket is full, it sinks, opening the valve.
The valve remains open until enough condensate
has passed out to allow the bucket to float, thus
closing the valve.

Thermostatic Steam Traps


There are several types of thermostatic steam traps.
In general, these traps are more compact and have
fewer moving parts than most mechanical steam
traps. The operation of a bellows-type thermostatic
trap is controlled by expansion of the vapor of a
volatile liquid enclosed in a bellows-type element.
Steam enters the trap body and heats the volatile
liquid in the sealed bellows, thus causing expansion
of the bellows.
The valve is attached to the bellows in such a way
that the valve closes when the bellows expands.
The valve remains closed, trapping steam in the
trap body. As the steam cools and condenses, the
bellows cools and contracts, thereby opening the
valve and allowing the condensate to drain.
The impulse and bimetallic steam traps are two
examples of those that use the thermostatic Figure 9-36 — Bucket-type steam trap.
principle.

9-31
Impulse Steam Traps
Impulse steam traps of the type
shown in Figure 9-37 are
commonly used in steam drain
collecting systems aboard ship.
Steam and condensate pass
through a strainer before
entering the trap. A circular
baffle keeps the entering steam
and condensate from impinging
on the cylinder or on the disk.
The impulse trap operates on the
principle that hot water under
pressure tends to flash into steam
when the pressure is reduced. So
that you understand how this
principle is used, let us consider
the arrangement of the parts
shown in Figure 9-37 and see
what happens to the flow of Figure 9-37 — Impulse steam trap.
condensate under various
conditions.
The only moving part in the steam trap is the disk, which is rather unusual in design. Near the top of
the disk is an insert that acts as a piston. As you can see in the figure, the working surface above the
insert is larger than the working surface below the insert. The importance of having this larger effective
area above the insert is brought out later in this discussion.
A control orifice runs through the disk from top to bottom and is considerably smaller at the top than
at the bottom. The bottom part of the disk extends through and beyond the orifice in the seat. The
upper part of the disk (including the insert) is inside a cylinder. The cylinder tapers inward, so the
amount of clearance between the insert and the cylinder varies according to the position of the valve.
When the valve is open, the clearance is greater than when the valve is closed.
When the trap is first cut in (put in service), pressure from the inlet (chamber A) acts against the
underside of the insert and lifts the disk off the valve seat. Condensate is thus allowed to pass out
through the orifice in the seat. At the same time, a small amount of condensate (control flow) flows up
past the insert and into chamber B. The control flow discharges through the control orifice, into the outlet
side of the trap. The pressure in chamber B remains lower than the pressure in chamber A.
As the line warms up, the temperature of the condensate flowing through the trap increases. The
reverse taper of the cylinder varies the amount of flow around the insert. This variation continues until
a balanced position is reached in which the total force exerted above the insert is equal to the total
force exerted below the insert. It is important to note that there is still a pressure difference between
chamber A and chamber B. The force is equalized because the effective area above the insert is larger
than the effective area below the insert. The difference in working area is such that the valve maintains
an open, balanced position when the pressure in chamber B is 86 percent of the pressure in chamber
A.
As the temperature of the condensate approaches its boiling point, some of the control flow going to
chamber B flashes into steam as it enters the low-pressure area. The steam has a much larger volume
than the water from which it is generated. Therefore, pressure is built up in the space above

9-32
the insert (chamber B). The pressure in this space becomes greater than 86 percent of the inlet
pressure. At that time, the force exerted on the top of the insert pushes the entire disk downward and
closes the valve.
With the valve closed, the only flow through the trap is past the insert and through the control orifice.
When the temperature of the condensate entering the trap drops slightly, condensate enters chamber B
without flashing into steam. Pressure in chamber B is thus reduced to the point that the valve opens and
allows condensate to flow through the orifice in the valve seat. Thus, the entire cycle is repeated.
With a normal condensate load, the valve opens and
closes at frequent intervals. A small amount of
condensate discharges at each opening. With a heavy
condensate load, the valve remains wide open and
allows a heavy, continuous discharge of condensate.

Bimetallic Steam Traps


These traps are used in many ships to drain condensate
from main steam lines, auxiliary steam lines, and other
steam components. The main working parts of this
steam trap are a segmented bimetallic element and a
ball-type check valve (Figure 9-38).
The bimetallic element consists of several bimetallic
strips fastened together in a segmented fashion. One
end of the bimetallic element is fastened rigidly to a
part of the valve body. The other end, which is free to Figure 9-38 — Bimetallic steam trap.
move, is fastened to the top of the stem of the ball- type
check valve.
Line pressure acting on the check valve tends to
keep the valve open. When steam enters the trap
body, the bimetallic element expands unequally
because of the different response to temperature of
the two metals. The bimetallic element deflects
upward at its free end. This motion moves the valve
stem upward and closes the valve. As the steam
cools and condenses, the bimetallic element moves
downward toward the horizontal position.
This movement opens the valve and allows some
condensate to flow out through the valve. As the
flow of condensate begins, it creates an unbalance
of line pressure across the valve. Since the line
pressure is greater on the upper side of the ball of
the check valve, the valve now opens wide and
allows a full capacity flow of condensate.

Orifice-Type Steam Traps


Figure 9-39 shows the assembly of an orifice-type
steam trap. Constant-flow drain orifices may be
used in systems of 150 psi and above where
Figure 9-39 — Orifice-type steam trap.
condensate load and pressure remain near
constant.

9-33
The constant-flow drain orifice operates on a thermodynamic principle; the variable density of
condensate helps its operation. Density changes with temperature. As the temperature of the
condensate decreases, the density of the condensate increases, as does the flow of the condensate
through the orifice. The reverse is also true. As the temperature of the condensate increases, the density
of the condensate decreases, as does the flow of the condensate through the orifice.
Because of the difference in densities between the steam and the condensate, the condensate will flow
through the orifice at a faster rate.
Other operating aspects of the orifice are size, pressure, and condensate load.
By calculating the condensate flow based on the condensing rate of the equipment and by knowing
the pressure of the system, you can select an orifice of the proper size. Flow rate through the orifice is
expressed in pounds per hour (lb/hr).
The advantages of the orifice-type trap over other types warrant its use in all systems of 150 psi and
above.

Maintenance
A strainer is installed just ahead of each steam trap. The strainer must be kept clean and in good
condition to keep scale and other foreign matter from getting into the trap. Scale and sediment can clog
the working parts of a steam trap and seriously interfere with the working of the trap.
Steam traps that are not operating properly can cause problems in systems and machinery. One way
to check on the operation of a steam trap is to listen to it. If the trap is leaking, you will probably be able
to hear it blowing through. Another way to check the operation of steam traps is to check the pressure
in the drain system. A leaking steam trap causes an unusual increase in pressure in the drain system.
When observing this condition, you can locate the defective trap by cutting out (isolating from the
system) traps, one at a time, until the pressure in the drain system returns to normal.
You should disassemble, clean, and inspect defective steam traps. After determining the cause of the
trouble, repair or replace parts as required. In some steam traps, you can replace the main working
parts as a unit; in others, you may have to grind in a seating surface, replace a disk, or perform other
repairs. You should reseat defective trap discharge valves. Always install new gaskets when
reassembling steam traps.

FILTERS AND STRAINERS


A variety of strainers and filters are used in Navy installations. According to Navy terminology, all metal-
edge and wire-mesh devices are classed as strainers. Devices that have replaceable, absorbent
cartridges are called filters. Filters remove smaller particles than strainers do. The location and number
of strainers and filters will vary, depending on the type of installation.

Strainers
Lubricating oil strainers may be either simplex or duplex. A duplex strainer is two strainer elements in
one assembly. A manual valve directs the flow of oil through either of the elements. When duplex
strainers are used, one element can be bypassed, and the element can be removed and cleaned without
disturbing the flow of oil through the other element to the engine.
Every approved lubricating oil strainer has a built-in, spring-loaded or differential area, pressure-relief
valve. The valve must be sufficiently large to bypass all of the oil around a clogged strainer to maintain
an uninterrupted flow of oil to the engine.

9-34
Simplex Strainer
Metal-edge strainers consist of a strainer element
surrounded by a case that serves as a sump to collect
foreign material and water. The element has an edge-
wound metal ribbon or a series (stack) of edge-type disks.
Most strainers have devices for manually rotating the
strainer element against metallic scrapers, which remove
the material caught by the element. Strainers usually have
vents for releasing air from the system. An edge-wound
metal ribbon strainer is shown in Figure 9-40.

Duplex Strainer
A duplex strainer of the edge-disk type is shown in Figure
9-41. The strainer consists of two sections, each of which
contains two strainer elements. A control valve between the
two sections secures one section while the other remains in
operation. The secured section acts as a standby unit; it may
be opened for cleaning and inspection without interrupting
the straining operation.

Wire-Mesh (Screen) Strainer


Figure 9-40 — Edge-wound metal
Strainers installed on the suction or intake side of the
pressure pumps are generally of the wire mesh (screen) ribbon lube oil strainer.
type and are referred to as coarse strainers. Some screen-
type strainers are located in the oil pan or sump.

Figure 9-41 — Edge-disk lube oil strainer.


9-35
Filters
In filters approved by the Navy, the absorbent
material is composed of such substances as
cellulose, cotton yarn, and paper disks. Filters
may be located directly in the pressure-
lubricating oil system, or they may be installed as
bypass filters. When installed in the pressure
system, a filter must contain a built- in, spring-
loaded, pressure-relief valve. The valve must be
large enough to bypass all oil to the engine in
case the filter element becomes restricted. A
bypass filter has an orifice plate in the line to the
filter. This component controls the amount of oil
removed from the lubricating oil pressure
system. (The amount of oil that flows through a Figure 9-42 — Tank-type lube oil filter.
bypass filter is only a small percentage of the oil
that flows through the pressure system.) The oil
from a bypass filter is returned to the sump tank.
Examples of some of the filters with which you
will come into contact are shown in Figure 9-42.
There are three general areas in a system for
locating a filter: the inlet line, the pressure line,
or a return line. Both filters and strainers are
available for inlet lines. Filters are normally used
in other lines. Figure 9-43 shows a typical
pressure line and return line filter arrangement
in a hydraulic system.

Pressure Line Filters


A number of filters are designed for installation
right in the pressure line (Figure 9-43) and can
trap much smaller particles than inlet line filters.
Such a filter might be used where system
components, such as valves, are less dirt-
tolerant than the pump. The filter thus would trap
this fine contamination from the fluid as it leaves
the pump. Pressure line filters must be able to
withstand the operating pressure of the system.

Return Line Filters


Return line filters (Figure 9-43) also can trap Figure 9-43 — Typical filter arrangement in
very small particles before the fluid returns to
hydraulic system.
the reservoir/tank. They are particularly useful
in systems that do not have large reservoirs/tanks to allow contaminants to settle out of the fluid. A
return line filter is usually necessary in a system with a high-performance pump, which has very close
clearances and usually cannot be sufficiently protected by an inlet line filter.

9-36
Fuel Filters
The fuel filter operates by passing fuel
through a porous element that removes
particles large enough to cause problems in
the system (Figure 9-44). Particles are
often measured in microns. A micron is one
millionth of a meter. Some filters serve as
sediment bowls. These types of filters
separate water and larger particles from the
fuel. After separation, the water and
particles settle to the bottom of the bowl,
where they can be removed through a drain
plug.

Filter/Strainer Materials
The materials used in filters and strainers
are classified as mechanical, absorbent, or
adsorbent.
Filter elements can be made of ceramic,
treated paper, sintered bronze, or metal screen Figure 9-44 — Fuel filter operation.
(Figure 9-45). Some filter elements
are made of laminated disks that are spaced 0.0003
inch apart. Foreign matter is blocked out as the fuel
passes between the disks.
Most strainer material is of the mechanical type, which
operates by trapping particles between closely woven
metal screens and/or disks, and metal baskets. The
mechanical type of material is used mostly where the
particles removed from the medium are of a relatively
coarse nature.
Absorbent filters are used for most minute particle
filtration in fluid systems. They are made of a wide
range of porous materials, including paper, wood pulp,
cotton, yarn, and cellulose. Paper filters are usually
resin-impregnated for strength.
Adsorbent (or active) filters, such as charcoal and
fuller’s earth, are used mostly in gaseous or vaporous
systems. This type of filter material should not be
used in hydraulic systems since they remove
essential additives from the hydraulic fluid. Figure 9-45 — Filter elements.
Construction of Filter Elements
Filter elements are constructed in various ways.
Surface-type filter elements are made of closely woven fabric or treated paper with pores to allow fluid
to flow through. Very accurate control of the pore size is a feature of the surface-type elements.

9-37
A depth-type filter element is composed of layers of a fabric or fibers, which provide many tortuous
paths for the fluid to flow through. The pores or passages vary in size, and the degree of filtration
depends on the flow rate. Increases in flow rate tend to dislodge trapped particles. This filter is limited
to low-flow, low pressure-drop conditions.
An edge-type filter element separates particles from fluids passing between finely spaced plates. The
filter shown in Figure 9-45 features stationary cleaner blades that scrape out the collected contaminants
when the handle is twisted to turn the element.

Types of Filters
In this section we will discuss the various filters (full flow, proportional flow, and indicator) that you will
most frequently find installed in equipment.

Full-Flow Filters
The term “full-flow” applied to a filter means that all the flow into the filter inlet port passes through the
filtering element. In most full-flow filters, however, there is a bypass valve preset to open at a given
pressure drop and divert flow past the filter element. This prevents a dirty element from restricting flow
excessively. Figure 9-46 shows a full-flow filter. Flow, as shown, is out-to-in; that is, from around the
element, through it to its center. The bypass opens when total flow can no longer pass through the
contaminated element without raising the system pressure. The element is replaceable after removing
a single bolt.

Figure 9-46 — Hydraulic filter assembly incorporating differential pressure.


9-38
Proportional-Flow Filters
A proportional-flow filter (Figure 9-47) may use the
venturi effect to filter a portion of the fluid flow. The
fluid can flow in either direction. As it passes through
the filter body, a venturi throat causes an increase
in velocity and a decrease in pressure.
The pressure difference forces some of the fluid
through the element to rejoin the main stream at
the venturi. The amount of fluid filtered is
proportional to the flow velocity. Hence, the name
proportional-flow filter.

Indicating Filters
Indicating filters are designed to signal the operator
when the element needs cleaning. There are various
types of indicators, such as color-coded, flag, pop-up,
and swing arm. Figure 9-48 shows a color-coded
indicating filter. The element is designed so it begins
to move as the pressure increases due to dirt
accumulation. One end is linked to an indicator that
shows the operator just how clean or dirty the
element is. Another feature of this type of filter is the
ease and speed with which the element can be Figure 9-47 — Proportional-flow filter.
removed and replaced. Most filters of this kind are
designed for inlet line installation.

Filter/Separator
The filter/separator is a two-stage unit consisting of
a coalescer stage and a separator stage within a
single housing. Each stage is made up of
replaceable elements, the number of which is
determined by such considerations as the capacity
of the elements in gallons per minute (gpm) and the
elements’ dirt retaining properties. Coalescer
elements filter solids from the fluid and cause small
particles of undissolved water to combine
(coalesce) into larger drops of water that, because
of their weight, will settle in the filter/separator
sump. Separator elements are provided to remove
any remaining free water that has not coalesced.
Water that accumulates in the filter/separator sump
is removed through a drain line, either
automatically or manually. Figure 9-48 — Color-coded indicating filter.
In-Line or Cone Filter
In-line or cone filters have conical-shaped fine mesh screen or perforated metal sheet that is inserted
into the system pipe and secured by a set of flanges. Its system application determines whether it is

9-39
considered a filter or strainer. It is most commonly used in seawater systems, where it is considered a
strainer. This type of filter is prohibited in fuel systems.

Maintenance
Proper operation of filters, strainers, and filter separators is essential for satisfactory gas turbine and
diesel engine performance. Besides clogging the systems with foreign matter, continued operation with
unfiltered fluids results in accelerated pump wear and system degradation.

PIPING
The control and application of fluid power would be impossible without a suitable means of conveying
the fluid from the power source to the point of application. Fluid lines used for this purpose are called
piping. They must be designed and installed with the same care applicable to other components of the
system. To obtain this desired result, attention must be given to the various types, materials, and sizes
of lines available for the fluid power system. The different types of lines and their application to fluid
power systems are described in the first part of this section. The last part of this section is devoted to
the various connectors applicable to the different types of fluid lines.

Identification of Piping
The three types of lines used in fluid power systems are tubing (semi rigid), pipe (rigid), and hose
(flexible). A number of factors are considered when the type of line is selected for a particular system.
These factors include the type of fluid, the required system pressure, and the location of the system.
For example, heavy pipe might be used for a large stationary system, but comparatively lightweight
steel tubing is used in the automotive brake system. Flexible hose is required in installations where
units must be free to move relative to each other.
The choice between pipe and tubing depends on system pressure and flow. The advantages of tubing
include easier bending and flaring, fewer fittings, better appearance, better reusability, and less leakage.
However, pipe is cheaper and will handle large volumes under high pressures. Pipe is also used where
straight-line hookups are required and for more permanent installations.

Piping Materials
The pipe and tubing used in fluid systems today are commonly made from steel, copper, brass,
aluminum, and stainless steel. The hose assemblies are constructed of rubber or Teflon®. Each of these
materials has its own distinct advantages or disadvantages, depending upon its application.
Steel piping and tubing are relatively inexpensive, have a high tensile strength, are suitable for bending
and flanging, and are very adaptable to high pressures and temperatures. Their chief disadvantage is
a comparatively low resistance to corrosion.
Copper and brass piping and tubing have a high resistance to corrosion and are easily drawn or bent.
Pipe or tubing made from these materials is unsuitable for systems with high temperatures, stress, or
vibration because they have a tendency to harden and break.
Aluminum has many characteristics and qualities required for fluid systems. It has a high resistance
to corrosion, is lightweight, is easily drawn or bent, and (when combined with certain alloys) will
withstand high pressures and temperatures.
Plastic tubing lines are made from a variety of materials; nylon is the most suitable for use in low-
pressure hydraulic applications ONLY.
Stainless steel piping or tubing is relatively lightweight and is used in a system that will be exposed to
abrasion, high pressure, and intense heat. Its main disadvantage is high cost.
9-40
FLEXIBLE HOSE ASSEMBLIES
The flexible hose assembly is a specific type of flexible device that uses reinforced rubber hose and
metal end fittings. Hose assemblies are used to connect moving parts with stationary parts and in
locations subject to severe vibration. Hose assemblies are heavier than aluminum-alloy tubing and
deteriorate more rapidly.
Flexible hose is used in fluid power systems where there is a need for flexibility, such as connection
to units that move while in operation or to units attached to a hinged portion of the equipment. It is
used to absorb motions between resiliently mounted machinery and fixed or resiliently mounted piping
systems. The motions to be considered may be of either relatively large size due to high- impact
shock or of smaller size due to the vibratory forces of rotating machinery. The configuration selected
must contain enough hose to accommodate shock and vibratory motions without stressing the hose
assembly or machinery to an unacceptable degree.
Flexible hose is provided in four pressure ranges. Low-pressure hose is used in a low-pressure system
and for the exhaust lines of high-pressure systems. Medium-pressure hose is used in systems with
pressures up to 1,200 psi; high-pressure hose is used with pressures up to 3,000 psi; and extra high-
pressure hose is used in systems with pressures up to 5,000 psi. High- and extra high- pressure hoses
normally come as complete assemblies with factory-installed end fittings. Medium- and low-pressure
hose are available in bulk and are usually fabricated locally. Hose assemblies are made up of hose and
hose fittings. A hose consists of multiple layers of various materials to include aluminum, carbon steel,
and corrosion-resistant steel (CRES).
Rubber hose is designed for specific fluid,
temperature, and pressure ranges and is
provided in various specifications. Flexible
hydraulic hose is composed of three basic parts.
An example of a flexible hose is shown in Figure
9-49.
The inner tube is a synthetic rubber layer that is
oil-resistant. It must be smooth, flexible, and able
to resist heat and corrosion.
The reinforcement layers vary with the type of
hose. These layers (or plies) are constructed of
natural or synthetic fibers, braided wire, or a
combination of these. The strength of this layer
depends upon the pressure requirement of the
system.
The outer cover protects the reinforcement
layers. A special rubber is most commonly used
for the outer layer because it resists abrasion and
exposure to weather, oil, and dirt.
Figure 9-49 — Flexible rubber hose construction.
Hose Identification
It is important that the proper hose to be used is clearly identified by various recognizable hose
markings.
Hose built to military specification (MILSPEC) requirements have the number of the specification and,
where applicable, the class of hose, the quarter and year of manufacture, and the manufacturer’s
trademark. This information is molded or otherwise permanently repeated periodically on the hose

9-41
cover (sometimes referred to as the “lay line marking”). Other information permanently marked on the
hose cover is the manufacturer’s code and the date of manufacture. For interpretations of commercial
lay line markings, refer to the appropriate manufacturer’s catalog or manual.

Synthetic Rubber
Synthetic rubber hose (if rubber-covered) is identified by the indicator stripe and markings that are
stenciled along the length of the hose. The indicator stripe (also called the lay line because of its use
in determining the straightness or lie of a hose) is a series of dots or dashes. The markings (letters
and numerals) contain the MILSPEC, hose size, cure date, and manufacturer's federal supply code
number. This information is repeated at intervals of 9 inches. Refer to Figure 9-50.

Figure 9-50 — Synthetic rubber hose identification.


Size is indicated by a dash followed by a number (referred to as a dash number). The dash number does
not denote the inside or outside diameter of the hose. It refers to the equivalent outside diameter of
rigid tube size in sixteenths (1/16) of an inch. A dash 8 (-8) mates to a number 8 rigid tube, which has
an outside diameter of one-half inch (8/16). The inside of the hose will not be one- half inch, but slightly
smaller to allow for tube thickness. The cure date is provided for age control. It is indicated by the quarter
of the year and year. The year is divided into four quarters.
1st quarter — January, February, March 2rd
quarter — April, May, June
3rd quarter — July, August, September
4th quarter — October, November, December
The cure date is also marked on bulk hose containers in accordance with Military Standard 129 (MIL-
STD-129).
Synthetic rubber hose (if wire-braid covered) is identified by bands wrapped around the hose at the
ends and at intervals along the length of the hose. Each band is marked with the same information
(Figure 9-50).

9-42
Teflon® Hose
Teflon® hose is identified by metal bands or pliable plastic bands at the ends and at 3-foot intervals.
These bands contain the hose MILSPEC number, size indicated by a dash (-) and a number, operating
pressure, and the manufacturer's federal supply code number. Refer to Figure 9-50.

Fitting Identification
Hose fittings are designed and constructed in accordance with MILSPEC and military standard drawings
for particular hose configurations and operating pressures.
Fittings designated by a military standard drawing number have a particular dash number to indicate
size. The fitting dash number does not designate a size in the same manner as a hose dash number.
The fitting dash number corresponds to the dash number of the hose so that both will match at the
critical dimensions to form a hose assembly.
Materials used in the construction of fittings vary according to the application. Materials include
aluminum, carbon steel, and corrosion-resistant steel. Fittings that qualify under one military document
may be produced by several manufacturers. Two methods or styles are used to secure the hose fitting
to the hose. They are the reusable and swage or crimp style.

Reusable Style
The preferred reusable style has modified internal threads in the socket to grip the hose properly. The
fitting can be disassembled from a hose assembly and reused on another hose, provided it passes an
inspection for defects. Reusable style fittings are authorized replacement fittings for replacement hose
assemblies.

Swage or Crimp Style


Some hose assembly manufacturers use a swage or crimp style. This style requires the socket to be
permanently deformed by an electric- or hydraulic-powered machine. The deformed socket and related
hardware are to be scrapped.
Flexible hose connectors are designed to be either permanent or reusable and are made of forged
steel. There are various types of end fittings for both the piping connection side and the hose connection
side of hose fittings (Figure 9-51).

CAUTION
If hoses and fittings are matched incorrectly, the results can
be pinhole leaks, ruptures, heat buildups, pressure drops,
cavitations, and other failures.

9-43
Figure 9-51 — Flexible hose connectors.

Hose Assembly Identification


All hose assemblies are identified by tags, bands, or tapes. Some identifications are permanently
marked while others are removable. Removable tags, bands, or tapes should not be installed on hose
assemblies located inside fuel and oil tanks or in areas of an aircraft where tags, bands, or tapes could
be drawn into the engine intake. Hose assemblies are either commercially manufactured or locally
fabricated.
Commercially manufactured Teflon® hose assemblies are identified by a permanently marked and
attached band on the assembly. The band contains the assembly manufacturer's name or trademark,
hose manufacturer's federal supply code number, hose assembly part number, operating pressure in
psi, pressure test (PT) symbol, and the date of hose assembly manufacture (in month and year).
Hose assemblies manufactured by depot and intermediate maintenance activities are identified with
hose assembly identification tags or labels. The hose assembly identification tag is a metal tag that
contains the basic hose assembly and part number, date of fabrication (in quarter and year), operating
pressure (in psi), and organizational code of the activity fabricating the hose assembly.
Figure 9-52 shows where this information is located. All marking of the tag is to be done prior to its
attachment to the hose assembly.

9-44
The hose assembly identification tag should be
installed by wrapping the band snugly around the
hose, inserting the tab through the slot and pulling it
tight; crimping the tab after bending the tab back;
and finally, cutting away the excess tab after
crimping. A length of not less than one-half inch
must remain between the tag and the end fitting
after proof pressure testing has been performed.
Labels should be used (Figure 9-53) to identify hose
assemblies located in areas where a tag may be
drawn into an engine intake or where hose
assemblies are covered with heat-shrinkable tubing.
The label should be placed 1 inch from the socket
and a 2 1/2-inch piece of clear, heat- shrinkable
tubing, MIL-PRF-46846, Type V, applied over the Figure 9-52 — Hose assembly identification
label and hose. tags.

Approved Flexible Hose Configurations


The arrangements (or configurations) determined to
give the best noise attenuation characteristics and to
accommodate the motions of resiliently mounted
equipment are shown in Figures 9-54 and 9-55. The
90° “L” configuration (dogleg) is the preferred
configuration; however, where space and piping
arrangement prohibit the use of the “L” configuration, a
180° or “U” configuration may be used. The 90° “L” and
180° “U” configurations are shown as sketches A and
B of Figure 9-54.

Figure 9-53 — Hose assembly labels.

A configuration that uses a single length of hose


bent to about 90° is approved where the hose does
not bend below its specified minimum bending
radius when the equipment moves to the maximum
limits allowed by its mounts (Figure 9- 55, view A).
The straight single hose configuration and the 180°
single hose bend (Figure 9-55, view
B) are also approved for use where the hose size
is less than 1 inch inside diameter (ID).

Figure 9-54 — Types of flexible hose


installations and fittings.
9-45
Figure 9-55 — Other approved single hose length configurations.

Inspection of Hose and Fittings Prior to Make-Up


The basic inspection methods for hose and fittings are listed as follows:
1. Ensure that the hose and couplings are the correct ones for the intended use.

NOTE
Synthetic rubber hose, bulk or assembly, shall have a shelf
life not to exceed 10 years (40 quarters) from the cure date.
Hoses and hose assemblies made from Teflon® (PTFE) do
not have shelf life limitations.

2. Inspect for signs that the hose has been twisted. Use the hose lay line for a guide to determine
whether or not any twist is present. If twisted, reject.
3. Inspect for signs that the hose has been kinked or bent beyond its minimum bend radius. If
suspect, reject.
4. Inspect for signs of loose inner liner. If found, cut the hose to see if this condition exists
throughout the entire length. If suspect, reject.

9-46
5. Visually check the inner liner and outer rubber cover of the hose for breaks, hairline cuts, or
severe abrasions. If any suspect areas are found, reject.
6. Inspect the fittings for defects, such as cracked nipples and damaged threads. If suspect, or if
defects are found, reject.

Visual Inspection
After assembling the hose and fittings, visually inspect the entire configuration to ensure the following:
1. The hose inner liner and outer cover is intact and contains no cuts or harmful abrasions.
2. The hose has not been twisted (check the lay line).
3. The circumferential chalk line on the hose next to the coupling has been drawn before the
hydrostatic test.
4. The internal spring (if installed) is evenly spaced and flat against the inner liner. Ensure a gap
exists between one of the end fittings and the end of the spring.
Flexible hose must NOT be twisted on installation
since this reduces the life of the hose considerably and
may cause fittings to loosen as well. You can
determine whether or not a hose is twisted by looking
at the lay line that runs along the length of the hose.
This lay line should not tend to spiral around the hose.
Hose should be installed so that it will be subjected to
a minimum of flexing during operation. Support clamps
are not necessary with short installations, but with
hoses of considerable length (48 inches, for example);
clamps should be placed not more than 24 inches
apart. Closer supports are desirable and, in some
cases, needed.
Hose must NEVER be stretched tight between two
fittings. About 5 to 8 percent of the total length must be
allowed as slack to provide freedom of movement
under pressure. When flexible hose is under pressure, Figure 9-56 — Correct and incorrect
it contracts in length and expands in diameter. installation of flexible hose.
Examples of correct and incorrect installations of
flexible hose are shown in Figure 9-56.

Hydrostatic Test
Upon completion of visual inspection, hydrostatically shop test the hose assembly with freshwater.
When you test pressure, hold for not more than 5 minutes nor less than 60 seconds. When test pressure
is reached, visually inspect the hose assembly for the following defects:
1. Leaks or signs of weakness.
2. Twisting of the hose (this indicates that some twist existed before pressure was applied).
3. Slippage of the hose out of the coupling (a circumferential chalk line can help determine this).

9-47
If any of these defects occur, reject the assembly.

CAUTION
Do not confuse hose elongation under pressure with
coupling slippage. If the chalk line returns to near its
original position, no slippage has occurred and the
assembly is satisfactory. If there is any doubt, perform a
second test. If doubt persists after the second test, reject
the assembly.

Air Test
Hose assemblies intended for gas or air service must also be tested with air or nitrogen at 100 psi and
the assembly immersed in water. Random bubbles may appear over the hose and in the fitting area
when the assembly is first pressurized. Do not construe this as a defect. However, if the bubbles persist
in forming at a steady rate at any particular point on the hose, reject the assembly.

Installation of Flexible Hose Assemblies


After completion of tests, proceed as follows:
1. Install as soon as possible.
2. Do not leave the hose assembly around on decks or on docks where they can be subjected to
any form of abuse.
3. Make up hose assemblies as late as possible during the availability schedule to minimize the
chances of damage while the ship is being overhauled.
4. Install plastic dust caps, plugs, or tape ends to protect threaded areas until the hose assembly
is installed.
When installing flexible base connections, observe the following requirements:
1. Ensure each leg of hose is free of twist between end fittings.
2. Ensure the fixed piping near the flexible configuration is properly supported so that it does not
vibrate from the resiliently mounted equipment.
3. Ensure the configurations are clear of all surrounding structures and remain so when resiliently
mounted equipment moves through its maximum excursion under shock.
4. Locate flexible connections as close as possible to the sound-mounted unit.
5. Support the free elbow of the configuration with an approved pipe hanger so as not to sag or
otherwise unduly stress or distort the configuration.
6. Do not appreciably change the alignment of the hose configuration between the unpressurized
and pressurized conditions. If you do, you could cause misalignment or improper support at the
fixed end.
7. Leave the configuration in a condition where one end can hang down unsupported during
installation or dismantling of piping. Otherwise, you can damage the hose wire reinforcement.

Periodic Inspection by Ship’s Force


No less than once a quarter, preferably about once a month, visually inspect all flexible piping
connections to determine whether any signs of weakness or unusual conditions exist. Inspect the
9-48
hose in other systems semiannually. To assist you when performing this inspection, you should compile
a checkoff list of hose assemblies and locations for your assigned spaces or equipment. This list will
consist of all flexible devices installed (and their locations) together with a list of inspections to be
performed on each flexible device. When you perform the listed inspections, note the following:
1. Evidence of leakage at fitting ends.
2. Discoloration of fittings (possible indication wire reinforcement is rusting).
3. Slippage of hose out of fitting.
4. Twisting of hose or other distortion or unusual appearance.
5. Cracking of outer rubber cover.
6. Rubber cover rubbed thin by abrasion or chafing.
7. High pulsations, fluid hammer, or whipping caused by pressure pulsations.
8. Large vibrations due to improper supports at the fixed end.
9. Large area of hose covered with paint (The intent of this requirement is to eliminate having the
flexible hose connections deliberately painted. The hose does not have to be replaced if a few
paint drops inadvertently fall onto it. Do not attempt to clean off dried paint from the hose).
10. Broken, distorted, or otherwise damaged hangers.
11. Soft spots or bulges on hose body (indicates weakening of bond between outer rubber cover
and wire braid or deterioration of the reinforcing wire).
12. If results of visual inspection indicate weakening of hose or fittings, or makes hose configuration
suspect, replace the hose immediately, if at all possible. Keep under surveillance while under
pressure until it is replaced.
13. If necessary to remove a flexible hose configuration from the system, examine the interior of the
hose for cracks or other signs of deterioration of the inner liner. Do not damage the liner by trying
to dislodge sea growth. Do not remove the end fittings from any section of hose that is to be
installed.
14. Presence of identification tag.

Age Control and Service Life


Hose or hose assemblies fabricated from age-sensitive materials are subject to age control. The
following definitions are provided to clarify age control, acceptance life, shelf life, and service life:
• Age control—This refers to the efforts made during manufacture, purchase, and storage of age-
sensitive items and parts made from natural or synthetic rubber materials to assure conformance
to the applicable material and performance specifications. Age control is further defined in terms
of acceptance life and shelf life
• Acceptance life—This is the period of time from cure date to the procuring activity's
(organizational-, intermediate-, or depot-level activity) date of acceptance
• Shelf life—This refers to the period of time from the date of acceptance or delivery by the
organizational-, intermediate-, or depot-level activity to the date of use
• Service life—This is the period of time from the date of installation to the date of removal
• Installation date of the hose or hose assemblies must be identified by a tag

9-49
Acceptance Life and Shelf Life for Synthetic Rubber Hose and Hose Assemblies
The acceptance life (MIL-STD-1523) and shelf life (DOD 4140.27M) for synthetic rubber hose and hose
assemblies are established as follows:

NOTE
Teflon® (PTFE) rubber hose and hose assemblies do not
have shelf life limitations.

NOTE
Teflon® (PTFE) hose assemblies are replaced only on a
conditional basis.

• Synthetic rubber hose (bulk or assembly) must not exceed 8 years (32 quarters) from the cure
date, which must be stenciled on the rubber covering of the bulk hose or provided on an
identification band on the metal braid hose or on the hose assemblies
• Synthetic rubber hose and hose assemblies must not exceed 5 years (20 quarters) from the
date of delivery to the organizational-, intermediate-, or depot-level activity. The repair activity
maintains a record of delivery dates for bulk hose and hose assemblies to monitor shelf life
expiration dates

Service Life for Synthetic Rubber Hose Assemblies


Service life is 7 years (28 quarters) for synthetic rubber hoses in critical applications; that is, medium-
and high-pressure synthetic rubber hoses exposed to heat, weather, or fuel.

NOTE
Service life for Teflon® (PTFE) hose assemblies is
determined by Cognizant Field Activity and may be on a
conditional replacement or hard-time replacement.

Rejection Standards
Rejection and replacement of hose or hose assemblies after inspections are based on the standards
normally specified in the applicable maintenance instruction manual (MIM), MRC, and depot-level
specifications. Where rejection standards are not specifically outlined or if doubt exists as to the
acceptability of a hose or hose assembly, the hose or hose assembly should be replaced.

NOTE
Teflon® (PTFE) hose assemblies are replaced only on a
conditional basis.

Storage
Hose and hose assemblies fabricated from age-sensitive materials are subject to deterioration by
oxygen, ozone, sunlight, heat, moisture, or other environmental factors. These types of hoses and hose
assemblies should be stored in a dark, cool, dry place protected from circulating air, sunlight, fuel, oil,
water, dust, and ozone. (Ozone may be generated in an atmosphere where electricity is

9-50
discharged through oxygen or ambient air.) Hose or hose assemblies should be stored by sealing both
ends of bulk hose. Each hose or hose assembly should also be capped or plugged and stored on
racks that support and protect them. Hose or hose assemblies should be stored so that the oldest
items are issued first.

CAUTION
Do not store hose or hose assemblies in piles. Improper
storage will cause accelerated deterioration due to both
heat and moisture factors.

FITTINGS
Some type of connector must be provided to attach the pipe, tube, or hose to the other components
of the system and to connect sections of the line to each other. There are many different types of
connectors (commonly called fittings) provided for this purpose. Some of the most common types of
fittings are covered in the following paragraphs.

Threaded Joints
The threaded union
joints are the
simplest type of
pipe fittings. Figure
9-57 shows some
commonly used
types of unions.
Threaded fittings are
not widely used
aboard modern
ships except in low-
pressure water
piping systems. The
pipe ends
connected to the
union are threaded,
silver-brazed, or
welded into the tail
pieces (union
halves); then the two
ends are joined by
setting up (engaging
and tightening up
on) the union ring.
The male and
female connecting Figure 9-57 — Unions.
ends of
the tail pieces are carefully ground to make a tight metal-to-metal fit with each other. Welding or
silver-brazing the ends to the tail pieces prevents contact of the carried fluid or gas with the union
threading.

9-51
Bolted Flange Joints
Bolted flange joints are suitable for all
pressures now in use. The flanges are
attached to the piping by welding,
brazing, screw threads (for some low-
pressure piping), or rolling and bending
into recesses. Those illustrated in Figure
9-58 are the most common types of flange
joints used. Flange joints are
manufactured for all standard fitting
shapes, such as the tee, cross, elbow,
and return bend. The Van Stone and the
welded-neck flange joints are used
extensively where piping is subjected to
high pressures and heavy expansion
strains. The design of the Van Stone
flange makes it easier to line up the
fastening holes in the two parts of the
flange.
Figure 9-58 — Bolted flange piping joints.
Welded Joints
The majority of joints found in subassemblies of piping systems are welded joints, especially in high-
pressure piping. The welding is done according to standard specifications, which define the material
and techniques. Three general classes of welded joints are fillet-weld, butt-weld, and socket-weld
(Figure 9-59).

Figure 9-59 — Various types of welded joints.

9-52
Silver-Brazed Joints
Silver-brazed joints (Figure 9-60) are commonly used for joining nonferrous piping when the pressure
and temperature in the lines make their use practicable—temperatures must not exceed 425 °F; for
cold lines, pressure must not exceed 3,000 psi. The alloy is melted by heating the joint with an
oxyacetylene torch. This causes the molten metal to fill the few thousandths of an inch annular space
between the pipe and the fitting.

Figure 9-60 — Silver-brazed joints.

Unions
The union fittings are
provided in piping
systems to allow the
piping to be taken
down for repairs and
alterations. Unions are
available in many
different materials and
designs to withstand a
wide range of
pressures and
temperatures. Figure
9-61 shows some
commonly used types
of unions/threaded
pipe connectors. The
union is most
commonly used for
joining piping up to 2
inches in size.

Figure 9-61 — Threaded pipe connectors.


9-53
Flared Fittings
Flared-tube connectors are commonly used in
circulatory systems consisting of lines made of
tubing. These connectors provide safe, strong,
dependable connections without the necessity
of threading, welding, or soldering the tubing.
The connector consists of a fitting, a sleeve, and
a nut (Figure 9-62).
The fittings are made of steel, aluminum alloy,
or bronze. The fitting used in a connection
should be made of the same material as that of
the sleeve, the nut, and the tubing. For
example, use steel connectors with steel tubing
and aluminum alloy connectors with aluminum
alloy tubing. Fittings are made in union, 45- Figure 9-62 — Flared-tube connector.
degree and 90-degree elbows, tees, and
various other shapes (Figure 9-63).

Figure 9-63 —Flared-tube fittings.


9-54
Flareless Fittings
Flareless fittings are installed to conserve space and to reduce weight, installation time, and system
cleaning time. Do not use flareless fittings if you do not have enough space to properly tighten the nuts
or if you have to remove the equipment or piping for access to the fittings. An exception to this rule is
a gauge board. It is designed so it may be removed as a unit for repairs or alterations. Do not use
flareless fittings where you cannot easily deflect the piping to permit assembly and disassembly.
The flareless-tube connector (Figure 9-64) eliminates
all tube flaring, yet provides a safe, strong, and
dependable tube connection. This connector consists
of a fitting, a sleeve or ferrule, and a nut.
Before assembly, ensure the tubing end is square,
concentric, and free of burrs. For an effective fitting,
be sure the cutting edge of the sleeve or ferrule bites
into the periphery of the tube; you can do this by
presetting the ferrule.

FLANGE SPRAY SHIELDS


Flange spray shields (Figure 9-65) capture any fuel
that sprays from a fuel system flanged joint that has
developed a leak. The flange shield directs the fuel to
drip or dribble to a safe place. Dribbling fuel leaks are
much less dangerous than spraying leaks, but repairs
of any fuel leak must be accomplished immediately.

PIPE HANGERS Figure 9-64 — Flareless-tube connector.


Pipe hangers and supports are designed
and located to support the combined weight
of the piping, fluid, and insulation. They
absorb the movements imposed by thermal
expansion of the pipe and the motion of the
ship. The pipe hangers and supports prevent
excessive vibration of the piping and resilient
mounts or other materials.
They are used in the hanger arrangement to
break all metal-to-metal contact to lessen
unwanted sound transmissions.
One type of pipe hanger you need to
become familiar with is the variable spring
hanger. This is used to support the ship’s
bleed air piping. It provides support by
directly compressing a spring or springs. Figure 9-65 — Flange spray shields.
The loads carried by the hangers are
equalized by adjustment of the hangers
when they are hot. These hangers have load scales attached to them with a traveling arm or pointer
that moves in a slot alongside the scale. This shows the degree of pipe movement from cold to hot. The
cold and hot positions are marked on the load scale. You should check the hangers when they

9-55
are hot to ensure that the pointers line up with the hot position on the load scales. You can adjust
hangers that are out of position by loosening the jam nut on the hanger rod and turning the adjusting
bolt of the hanger.

INSPECTIONS AND MAINTENANCE


Reasonable care must be given to the various piping assemblies as well as to the units connected to
the piping systems. Unless the piping system is in good condition, the connected units of machinery
cannot operate efficiently and safely. You should be familiar with all the recommended maintenance
procedures and observe the safety precautions when working on piping systems.
The most important factor in maintaining piping systems in satisfactory condition is keeping joints,
valves, and fittings tight. To ensure this condition, you need to make frequent tests and inspections.
Piping should be tested at the frequency and test pressure specified following the PMS and the
applicable equipment technical manual. Test pressure must be maintained long enough to show any
leaks or other defects in the system.
Instruction manuals should be available and followed for the inspection and maintenance of piping
systems and associated equipment; however, if the manufacturer’s instruction manual is not available,
you should refer to the NSTM, chapter 505, for details of piping inspection and maintenance.

PIPING SYSTEM IDENTIFICATION MARKING


All piping should be marked to show the name of
the service, destination (where possible), and
direction of flow (Figure 9-66).
The name of the service and destination should
be painted on by stencil or hand lettering, or by
application of previously printed, stenciled, or
lettered adhesive-backed tape. Lettering will be
1 inch high for a 2-inch or larger outside diameter
(OD) bare pipe or insulation. For smaller sizes, Figure 9-66 — Pipe markings.
lettering size may be reduced or
label plates attached by wire or other suitable means.
Direction of flow will be indicated by an arrow 3 inches long pointing away from the lettering. For
reversible flow, arrows are to be shown on each end of the lettering.
Black is used for lettering and arrows. However, on dark-colored pipe (including oxygen piping), white
is used.
Markings will be applied to piping in conspicuous locations, preferably near the control valves and at
suitable intervals so every line will have at least one identification marking in each compartment through
which it passes. Piping in cabins and officers’ wardrooms will not normally be marked.

PACKING AND GASKET MATERIAL


Packing and gasket materials are required to seal joints in steam, water, gas, air, oil, and other lines
and to seal connections that slide or rotate under normal operating conditions. There are many types
and forms of packing and gasket materials available commercially.

9-56
Packing and Gasket Selection
To simplify the selection of packing and gasket materials commonly used in naval service, NAVSEA
has prepared a packing and gasket chart, Mechanical Standard Drawing B-153. It shows the symbol
numbers and the recommended applications for all types and kinds of packing and gasket materials.
The symbol number used to identify each type of packing and gasket has a four-digit number. The first
digit shows the class of service with respect to fixed and moving joints; the numeral 1 shows a moving
joint (moving rods, shafts, valve stems), and the numeral 2 shows a fixed joint (flanges, bonnets). The
second digit shows the material of which the packing or gasket is primarily composed—asbestos,
vegetable fiber, rubber, metal, and so forth. The third and fourth digits show the different styles or
forms of the packing or gasket made from the material.
Practically all shipboard packing and gasket problems can be solved by selection of the correct material
from the listings on the packing and gasket chart. The following examples show the kind of information
that you can get from the packing and gasket chart.
Suppose you are required to repack and install a valve in a 300 psi saturated steam line. By referring
to the packing and gasket chart, you will find several materials suitable for repacking the valve:
• Symbol 1103 Asbestos rod, braided, plain
• Symbol 1104 Asbestos rod, braided, wire insertion
• Symbol 1430 Metallic, flexible
Notice that the first digit is 1 in each case, to indicate that the packing is suitable for a moving joint.
To install a valve, you will need suitable gaskets. In this case, the first digit will be 2, indicating that
the gasket material is suitable for fixed joints. By referring to the packing and gasket chart, you will
find that you can use any of the following gasket materials:
• Symbol 2150 Asbestos, sheet, compressed
• Symbol 2151 Asbestos, metallic, cloth sheet
• Symbol 2410 Gasket, metallic, asbestos, spiral wound
In addition to the standard packing and gasket chart, most ships have a packing and gasket chart made
specifically for that ship. The shipboard chart shows the symbol numbers and the sizes of packing and
gaskets required in the ship’s piping systems, machinery, and hull fittings.

Packing of Moving Joints


Valves are components used to control the transfer of liquids
and gases through fluid piping systems. Most valves have
moving joints between the valve stem and the bonnet. When
fluid is on one or both sides of a moving joint, the joint may
leak. Sealing the joint prevents this leakage.
Sealing a moving joint presents a problem because the
seal must be tight enough to prevent leakage, yet loose
enough to let the valve stem turn without binding. Packing
is the most common method of sealing a moving joint.
Packing is a sealing method that uses bulk material
(packing) that is reshaped by compression to effectively
seal a moving joint. Figure 9-67 shows graphite filament
yarn. Figure 9-67 — Graphite filament yarn.
9-57
Packing is inserted in stuffing boxes that have annular chambers located around valve stems and
rotating shafts. The packing material is compressed to the necessary extent and held in place by gland
nuts or other devices.
Corrugated ribbon packing (CRP) (Figure 9-68) is a relatively new packing material; it is a 100- percent
graphite material expressly suited for installation in steam, feed, and condensate valves. CRP contains
no binders, resins, fillers, lubricants, or other additives. It has the lubricating quality typical of pure
graphite with the capability for rapid heat dissipation, thus reducing wear. Unlike conventional graphite,
which is brittle, CRP is flexible and highly resilient. When CRP is formed in a valve stuffing box, it
restructures.
This restructuring capability allows CRP to be wrapped around the valve stem in any size valve stuffing
box and to be formed into a solid, endless packing ring by compression.
CRP is easily cut to a predetermined length. It does not turn rock-hard or shrink at any temperature.
Once installed and after run-in, it normally needs no further adjustment. This means greatly reduced
maintenance. The resiliency and no-lint structure of CRP remain unchanged at any temperature.
There is no lubricant or additive to be squeezed out, vaporized, or carbonized. Also, it has a long
shelf and service life.

Packing of Fixed Joints


Figure 9-69 shows gasket material used for fixed
joints. At one time, fixed joints could be satisfactorily
sealed with gaskets of compressed asbestos sheet
packing (Figure 9-69, view A). Today the 15 percent
rubber content of the packing makes it unsatisfactory
for modern, high-temperature, high-pressure
equipment. Two types of gaskets (metallic or semi-
metallic) are in use in present day high-temperature
and high-pressure installations. Gaskets of corrugated
copper or of asbestos and copper are sometimes used
on low- and medium-pressure lines.
Serrated-face metal gaskets (Figure 9-69, view B)
made of steel, Monel, or soft iron have raised
serrations to make a better seal at the piping flange
joints. These gaskets have resiliency. Line pressure Figure 9-68 — Corrugated ribbon
forces the serrated faces tighter against the adjoining packing.
flange. The gaskets shown are of two variations.
Spiral-wound, metallic-asbestos gaskets (Figure 9-69, view C) are made of interlocked strands of
preformed corrugated metal and asbestos strips, spirally wound together (normally called the filler),
and a solid metal outer or centering ring (normally called the retaining ring). The centering ring is used
as a reinforcement to prevent blowouts. The filler piece is replaceable. When renewing a gasket, you
should remove this piece from the retaining metal ring and replace it with a new filler. Do not discard
the solid metal retaining outer or centering ring unless it is damaged. You can compress the gaskets
to the thickness of the outer or centering ring.

9-58
Precautions
When renewing a gasket in a
flange joint, you must exercise
special precautions when breaking
the joint, particularly in steam and
hot water lines, or in saltwater lines
that have a possibility of direct
connection with the sea. Be sure to
observe the following precautions:
• No pressure is on the line
• The line pressure valves,
including the bypass
valves, are firmly secured,
wired closed, and tagged
• The line is completely
drained
• At least two flange-securing
bolts and nuts diametrically
opposite remain in place
until the others are removed,
then slackened to allow
breaking of the joint, and
removed after the line is
clear Figure 9-69 — Fixed joint gasket. A. Sheet asbestos gasket.
• B. Serrated-face metal gasket. C. Spiral-wound, metallic-
Precautions are taken to
asbestos gasket.
prevent explosions or fire
when breaking joints of
flammable liquid lines
• Proper ventilation is ensured before joints are broken in closed compartments
These precautions may prevent serious explosions, severe scalding of personnel, or flooding of
compartments. You should thoroughly clean all sealing and bearing surfaces for the gasket
replacement. Check the gasket seats with a surface plate, and scrape as necessary. This affords
uniform contact. Replace all damaged bolt studs and nuts. In flange joints with raised faces, the edges
of gaskets may extend beyond the edge of the raised face.

O-R INGS
Another method of preventing leakage in fluid systems is by use of O-ring seals. An O-ring is circular
in shape, and its cross section is small in relation to its diameter. O-rings are usually molded from rubber
compounds; however, they can be molded or machined from plastic materials. The O-ring is usually
fitted into a rectangular groove (usually called a gland) machined into the mechanism to be sealed. An
O-ring seal consists of an O-ring mounted in the gland so that the O-ring’s cross section is compressed
(squeezed) when the gland is assembled (Figure 9-70).
When the gland is assembled (Figure 9-70, view B), the O-ring cross section is compressed. When
installed, the compression of the O-ring cross section enables it to seal low-fluid pressures. The

9-59
greater the compression, the greater is the fluid pressure
that can be sealed by the O-ring. The pressure of the O- ring
against the gland walls equals the pressure caused by the
recovery force of the compressed O-ring plus the fluid
pressure.
The fluid pressure against the walls of the gland and the
stiffness of the O-ring prevent fluid from leaking past the O-
ring. If the downstream clearance is large, the O-ring is
forced into this clearance (Figure 9-70, view C). The
stiffness of the O-ring material prevents the O-ring from
being forced completely through the downstream clearance
unless that clearance is abnormally large or the pressure is
excessive.
O-rings are commonly used for sealing because of their
simplicity, ruggedness, low cost, ease of installation, ease of
maintenance, and effectiveness over wide pressure and
temperature ranges. Failure of an O-ring can sometimes
begin with the removal of an old O-ring. If you incorrectly
remove an O-ring with pointed or sharp tools, you can
scratch or dent critical surface finishes that can result in seal
failure.
Before installing a new O-ring, inspect the sealing surfaces
for any abrasions and wipe them free of any dust, dirt, or
other contaminants. Before installation, inspect the O-ring
for any damage. If faulty, discard it. Figure 9-70 — O-ring seal with two
When you install the O-ring, lubricate it. In most cases it is cross-sectional views.
already coated with the system fluid or petroleum grease.
Do not stretch the O-ring more than twice its original size during installation, and do not roll or twist it
into place. This may leave a permanent twist in the O-ring and reduce its effectiveness and shorten its
life.
When installing an O-ring, take extreme care to avoid forcing it over sharp edges, corners, and threaded
sections. You should use some type of sleeve or cover to avoid damaging the O-ring.

FASTENERS
The proper use of fasteners is very important and cannot be overemphasized. Many shipboard
machinery casualties have resulted from fasteners that were not properly installed. Machinery
vibration, thermal expansion, and thermal contraction will loosen the fasteners. At sea, loosening
effects are increased by the pitch and roll of the ship. You are familiar with such standard fasteners
as nuts, bolts, washers, wingnuts, and screws. In this section we will discuss some of the new
developments in fastener technology, such as the various types of locknuts, which you may not be
familiar with.

Threaded Locking Devices


An important part of fastener technology has included the development of several methods for locking
mated threads of fasteners. Many of the latest methods include the locking device or method as an
integral part of the fastener assembly and are referred to as self-locking nuts or bolts. Self-locking

9-60
fasteners are more expensive than some older methods but compare favorably in cost with pin or wiring
methods.

Length of Protrusion
Male threads on threaded fasteners, when installed and tightened, will protrude the distance of at least
one thread length beyond the top of the nut or plastic locking ring. Excessive protrusion is a hazard,
particularly where necessary clearances, accessibility, and safety are important. Where practicable, the
number of threads protruding should not exceed five. In no case should thread protrusion exceed 10
threads unless specifically approved by the work supervisor. (This is the 1-to-10 rule.)
Where screw threads are used for setting or adjusting (such as valve stem packing glands and travel
stops) or where installed threaded fasteners do not strictly follow the 1-to-10 rule but have given
satisfactory service, the rule does not apply. An example of an acceptable existing installation would
be where a male thread is flush with the top of a nut or where more than 10 threads protruding is of
no foreseeable consequence.

Repair of Damaged Threads


You can remedy damaged external threads by replacing the fastener. In large equipment castings, you
must repair damaged internal threads to save the part. You can repair internal threads by redrilling the
damaged thread; clean and either install a solid wall insert or tap for a helical coil insert. These inserts,
in effect, return the tapped hole to its original size so it takes the original mating fastener.

Locknuts
Locknuts are used in special applications where you want to ensure that the components joined by the
fasteners will not loosen. Two types of locknuts are in common use. The first type applies pressure to
the bolt thread and can be used where frequent removal may be required. The second type deforms
the bolt thread and is used only where frequent removal is unnecessary. The first type includes nonself-
locking, self-locking, plain hex, castle, castellated, and check nuts. The second type includes distorted
collar nuts and distorted thread nuts; they are not commonly found in gas turbine equipment and will
not be covered in this section.

Nonself-Locking Nuts
Nonself-locking nuts require the use of a separate locking device for security of installation. There are
several types of these locking devices mentioned in the following paragraphs in connection with the
nuts on which they are used. Since no single locking device can be used with all types of nonself-
locking nuts, one must be selected that is suitable for the type of nut being used.

Self-Locking Nuts
Self-locking nuts provide tight connections that will not loosen under vibrations. Self-locking nuts
approved for use on aircraft meet critical strength, corrosion-resistance, and temperature specifications.
The two major types of self-locking nuts are prevailing torque and free spinning. The two general types
of prevailing torque nuts are the all-metal nuts and the nonmetallic insert nuts. New self-locking nuts
must be used each time components are installed in critical areas throughout the entire aircraft, including
all flight, engine, and fuel control linkage and attachments. The flexloc nut is an example of the all-metal
type. The elastic stop nut is an example of the nonmetallic insert type. All- metal self-locking nuts are
constructed with the threads in the load-carrying portion of the nut out of phase with the threads in the
locking portion, or with a saw cut top portion with a pinched-in thread.

9-61
The locking action of these types depends upon the resiliency of the metal when the locking section
and load-carrying section are forced into alignment when engaged by the bolt or screw threads.

Plain Hex Nuts


These nuts are available in self-locking or nonself-
locking styles. When the nonself-locking nuts are
used, they should be locked with an auxiliary
locking device such as a check nut or lock washer
(Figure 9-71).

Castle Nuts
These nuts are used with drilled shank bolts, hex-
head bolts, clevis bolts, eyebolts, and drilled-head
studs. These nuts are designed to be secured with
cotter pins or safety wire.

Castellated Nuts
Like the castle nuts, these nuts are castellated for
safety. They are not as strong or cut as deep as the
castle nuts. Figure 9-71 — Nuts.
Check Nuts
These nuts are used in locking devices for nonself-locking plain hex nuts, setscrews, and threaded rod
ends.

Lock washers
Many installations on board naval ships still use lock washers to prevent threaded fasteners from
loosening. If loosening has not been a problem, you may replace worn lock washers with an identical
type; however, if loosening has been a problem, you should use self-locking fasteners instead of lock
washers.
The most common lock washer used is the helical spring washer.
Other types are the conical and toothed tab.

Helical Spring Lock washers


The helical spring lock washer (split ring) (Figure 9-72) is flattened
when the bolt is torqued down. When torqued, it acts as a flat
washer contributing normal friction for locking the screw or bolt and
the working surface; it also maintains the tension on the bolt.
Because of the helical spring lock washer’s small diameter, it is
usually not used on soft materials or with oversized or elongated
holes. Figure 9-72 — Helical spring
lockwasher.
Curved or Conical Spring Lock washers
Curved or conical spring lock washers have almost the same properties as the helical spring lock
washer. They provide a constant tension on the bolt or screw when loosened. The tension produced is
usually less than that produced by the helical spring lock washer. Like any locking device relying on
tension, spring lock washers may loosen on shock loading. When the bolt stretches more

9-62
than the spring distortion from the shock loading, the washer serves no further purpose. Recheck the
washer, where possible, when shock is sufficient to suspect loosening. Some spring lock washers
have teeth on the outer edge. These teeth do not aid in locking, but they prevent side slippage and
turning.

Toothed Lock washers


Toothed lock washers (Figure 9-73) have teeth that are twisted or
bent to prevent loosening. Cutting edges engage both working
surfaces on the nut and bolt or screw. Some have teeth on the inner
diameter for applications where teeth projecting beyond the nut are
not desired. The most common type has teeth on the outer diameter.
Washers with teeth on both inside and outside diameters are used
for soft materials and oversize holes. The teeth are twisted, so as Figure 9-73 — Toothed
the nut is installed and torqued down, the rim of the washer supports lock washers.
the pressure. Any backing off of the nut or bolt releases tension that
allows the teeth to dig into the working surfaces of the nut and bolt.

INSULATION
The purpose of insulation is to retard the transfer of heat from piping that is hotter than the surrounding
atmosphere or to piping that is cooler than the surrounding atmosphere. Insulation helps to maintain
the desired temperatures in all systems. In addition, it prevents sweating of piping that carries cool or
cold fluids. Insulation also serves to protect personnel from being burned by coming in contact with hot
surfaces. Piping insulation represents the composite piping covering, which consists of the insulating
material, lagging, and fastening. The insulating material offers resistance to the flow of heat; the
lagging, usually of painted canvas, is the protective and confining covering placed over the insulating
materials; and the fastening attaches the insulating material to the piping and to the lagging.
Insulation covers a wide range of temperatures, from the extremely low temperatures of the refrigerating
plants to the very high temperatures of the ship’s waste heat boilers. No one material could possibly be
used to meet all the conditions with the same efficiency.

Insulation Materials
The following quality requirements for the various insulating materials are taken into consideration by
the Navy in the standardization of these materials:
• Low heat conductivity
• Noncombustibility
• Lightweight
• Easy molding and installation capability
• Moisture repellant
• Noncorrosive, insoluble, and chemically inactive
• Composition, structure, and insulating properties unchanged by temperatures at which it is to
be used

9-63
• Once installed, should not cluster, become lumpy, disintegrate, or build up in masses from
vibration
• Vermin proof
• Hygienically safe to handle
The insulating cements are comprised of a variety of materials, differing widely among themselves as
to heat conductivity, weight, and other physical characteristics. Typical of these variations are the
asbestos substitute cements, diatomaceous cements, and mineral and slag wool cements. These
cements are less efficient than other high-temperature insulating materials, but they are valuable for
patchwork emergency repairs and for covering small irregular surfaces (valves, flanges, joints, and so
forth). Additionally, the cements are used for a surface finish over block or sheet forms of insulation,
to seal joints between the blocks, and to provide a smooth finish over which asbestos substitute or
glass cloth lagging may be applied.

Flange Safety Shields


A fire in the engine room can be caused by a leak
at a fuel or lube oil pipe-flange connection. Even the
smallest leak can spray fine droplets of lube oil or
fuel on nearby hot surfaces, such as the exhaust
manifold of a diesel engine. To reduce this
possibility, spray shields (flange safety shields) are
installed on piping flanges of flammable liquid
systems, especially in areas where the fire hazard
is apparent (Figure 9-74).
The spray shields are usually made of aluminized
glass cloth and are simply wrapped and wired
around the flange.

Removable Insulation
Removable insulation will be found on the bleed
air systems and waste heat boiler systems.
Removable insulation is also installed in the Figure 9-74 — Flange safety shields.
following locations:
• Flange pipe joints adjacent to machinery or equipment that must be broken when units are
opened for inspection or overhaul
• Valve bonnets of valves larger than 2 inches internal pipe size (IPS) that operate at 300 psi
and above or at 240 °F and above
• All pressure-reducing and pressure-regulating valves, pump pressure governors, and strainer
bonnets

General Insulation Precautions


You should observe the following general precautions relative to the application and maintenance of
insulation:
• Fill and seal all air pockets and cracks. Failure to do this will cause large losses in the
effectiveness of the insulation

9-64
• Seal the ends of the insulation and taper off to a smooth, airtight joint. At joint ends or other
points where insulation is liable to be damaged, use sheet metal lagging over the insulation.
You should cuff flanges and joints with 6-inch lagging
• Keep moisture out of all insulation work. Moisture is an enemy of heat insulation just as much
as it is in electrical insulation. Any dampness increases the conductivity of all heat-insulating
materials
• Insulate all hangers and other supports at their point of contact from the pipe or other unit they
are supporting; otherwise, a considerable quantity of heat will be lost via conduction through the
support
• Keep sheet metal covering bright and unpainted unless the protective surface has been
damaged or has worn off. The radiation from bright-bodied and light-colored objects is
considerably less than from rough and dark-colored objects
• Once installed, heat insulation requires careful inspection, upkeep, and repair. Replace lagging
and insulation removed to make repairs as carefully as when originally installed. When replacing
insulation, make certain that the replacement material is of the same type as had been used
originally
• Insulate all flanges with easily removable forms. These forms are made up as pads of insulating
material, wired or bound in place, and the whole covered with sheet metal casings, which are
in halves
• Asbestos control: Inhalation of excessive quantities of asbestos fiber or filler can produce severe
lung damage in the form of disabling or fatal fibrosis of the lungs. Asbestos has also been found
to be a casual factor in the development of cancer of the membrane lining the chest and
abdomen. Lung damage and disease usually develop slowly and often do not become apparent
until years after the initial exposure. If your plans include a long and healthy Navy retirement, you
have no business doing asbestos lagging rip-out without proper training, protective clothing, and
supervision. Most systems of today’s modern Navy have been purged of asbestos and an
asbestos substitute material installed in its place. Some of the older class vessels may still have
some asbestos insulation installed. Use caution when handling lagging and insulation from these
vessels. If in doubt, contact your supervisor and request the medical department conduct a
survey of the material in question

SUMMARY
This chapter has given you general information on pumps, valves, and piping. It would be a good idea
to get some hands-on experience aboard your ship. Trace various systems out and see how they are
set up. Ask your LPO to explain the systems and how each part in the system works. The key phrase
here is ASK QUESTIONS!

9-65
End of Chapter 9
Pumps, Valves, and Piping
Review Questions

9-1. When a pump delivers energy to a liquid, it usually causes an increase in pressure, which is
generally referred to as what term?

A. Displacement
B. Energy
C. Head
D. Pressure increase

9-2. When a body or a liquid is made to revolve or whirl around a point, a force is created that
impels the body or fluid to move outward from the center of rotation. This phenomenon is
known as what term?

A. Centrifugal force
B. Centripetal force
C. Reactive displacement
D. Orthogonal displacement

9-3. How many impeller(s) does a single-stage pump have?

A. One
B. Two
C. Three
D. Four

9-4. What type of impeller has side walls that extend from the eye to the outer edge of the vane
tips?

A. Action
B. Closed
C. Double
D. Open

9-5. What part eliminates the problem of excessive stuffing box leakage?

A. Bearing
B. Gasket
C. Mechanical seals
D. Washer

9-66
9-6. What component is a chamber in the packing gland used to seal the shaft where it passes
through the pump casing?

A. Gland seal
B. Pump casing
C. Pump valve
D. Stuffing box

9-7. Which of the following is a cause that results in a centrifugal pump not being able to deliver
any liquid?

A. Air leakage into the suction line


B. Air leakage in the stuffing boxes
C. Insufficient priming
D. Insufficient speed of the pump

9-8. Which of the following is a cause that results in a centrifugal pump having insufficient
capacity?

A. Air leakage into the suction line


B. Air leakage in the stuffing boxes
C. Insufficient priming
D. Excessive suction lift

9-9. Which of the following pumps is a rotary type?

A. Action
B. Diffuser
C. Gear
D. Volute

9-10. What type of pump is used aboard ship to pump fuel and lube oil and to supply pressure to the
hydraulic system?

A. Centrifugal
B. Jet
C. Rotary
D. Screw

9-11. What type of pump is used for lube oil service and transfer, tank stripping, bilge, aircraft
fueling and defueling and, in general, for handling lighter viscous liquids?

A. Centrifugal
B. Jet
C. Rotary
D. Sliding vane

9-67
9-12. Which of the following is a type of jet pump?

A. Eductor
B. Centrifugal
C. Rotary
D. Screw

9-13. What component is intended to take care of only a slight misalignment of a shaft?

A. Flange
B. Flexible coupling
C. Shim
D. Wedge

9-14. What component is a feedback device that is used to provide automatic control of speed,
pressure, or temperature?

A. Control valve
B. Governor
C. Shaft sleeve
D. Steam trap

9-15. What type of valve is used to shut off or, in some cases, partially shut off the flow of fluid?

A. Butterfly
B. Gate
C. Start
D. Stop

9-16. What type of valve is used when a straight-line flow of fluid and minimum restriction is
desired?

A. Butterfly
B. Gate
C. Start
D. Stop

9-17. What type of valve permits liquids to flow through a line in one direction only?

A. Check
B. Gate
C. Start
D. Stop

9-68
9-18. What devices are installed in steam lines to drain condensate from the lines without allowing
the escape of steam?

A. Filters
B. Steam traps
C. Strainers
D. Spray shields

9-19. What type of strainer is generally installed on the suction or intake side of pressure pumps?

A. Cardboard
B. Duplex
C. Simplex
D. Wire-mesh

9-20. Which of the following items is a type of lubricating oil strainer?

A. Air-pilot
B. Duplex
C. Simtex
D. Duraplex

9-21. Surface-type filter elements are made of what material?

A. Cardboard
B. Copper
C. Metal
D. Woven fabric

9-22. What type of filter is designed to signal the operator when the element needs cleaning?

A. Full-flow
B. In-line
C. Indicating
D. Proportional-flow

9-23. Which of the following items is semi rigid?

A. Flexible hose
B. Piping
C. Tubing
D. Plastic hose

9-24. How many digits are in the symbol number used to identify each type of packing and gasket?

A. One
B. Two
C. Three
D. Four

9-69
RATE TRAINING MANUAL – User Update
SWOS makes every effort to keep their manuals up-to-date and free of technical errors. We appreciate
your help in this process. If you have an idea for improving this manual, or if you find an error, a
typographical mistake, or an inaccuracy in SWOS manuals, please write or e-mail us, using this form
or a photocopy. Be sure to include the exact chapter number, topic, detailed description, and correction,
if applicable. Your input will be brought to the attention of the Technical Review Committee. Thank
you for your assistance.
Write: SWOS Project Manager
1534 Piersey Street Suite 321
Norfolk, VA 23511-2613
COMM: (757) 444-5332
DSN: 564-5332
E-mail: Refer to the SWOS Norfolk page on the NKO Web page for current contact information.

Rate Course Name

Revision Date Chapter Number Page Number(s)

Description

(Optional) Correction

(Optional) Your Name and Address

9-70