DESIGN PARAMETERS

• DESIGN CRITERIA
fy = 414 MPa
f’c = 24 MPa

• DESIGN LOADS
A. DEAD LOADS
1. Weight of Concrete ---------------------------------------------------- 23.56 kN/m^3
2. Slab ----------------------------------------------------------------- 2.5 kN/M
3. Ceramic tile ------------------------------------------------------- 1.10 kN/M
4. Weight of Wall
▪ Exterior: 6” CHB ---------------------------------------------- 3.11 kPa
▪ Interior: 4” CHB ---------------------------------------------- 2.98 kPa
B. LIVE LOADS
1. Residential
▪ Basic floor area ---------------------------------------------- 1.9 kPa
▪ Exterior balconies ---------------------------------------------- 2.9 kPa
2. Stairs ----------------------------------------------------------------- 4.8 kPa
3. Dining ----------------------------------------------------------------- 4.8 kPa
4. Storage(light) -------------------------------------------------------- 6.0 kPa
5. Roof ------------------------------------------------------------------ 1.9 kPa

• DESIGN LOAD COMBINATION

ULTIMATE STRENGTH DESIGN (USD)


U = 1.2DL + 1.0LL + 1.0 EL