You are on page 1of 18

DEPARTMENT OF PUBLIC

WORKS AND HIGHWAYS


OFFICE OF THE BUILDING OFFICIAL

DISTRICT/CITY/MUNICIPALITY

BUILDING OFFICIAL

LAND USE AND ZONING

8.00

PROPERTY LINE EXISTING FENCE

1.00
LINE AND GRADE
2.00

PROPERTY LINE EXISTING FENCE


PERSPECTIVE VIEW ARCHITECTURAL
SCALE: NTS.

FIREWALL
PROPOSED

7.00
2-STOREY
TO CITY

10.00
PROPOER HOUSE
STRUCTURAL

SANITARY

THIS SITE

2.00
Phase 2, Block 2, Lot 12

PROPERTY LINE EXISTING FENCE

ELECTRICAL

ROAD LOT NO. 4 ( 8.00 M WIDE )

MECHANICAL

SITE DEVELOPMENT PLAN TO ABUNO LOCATION PLAN


SCALE: 1:250 MTS. SCALE: NTS.

FIRE AND SAFETY


SIGNED BY: REG NO.: SEAL PROJECT TITLE: APPROVED BY: SHEET CONTENTS SHEET NO.
PTR NO.:
PLACE ISSUED:
PROPOSED 2-STOREY PERSPECTIVE A-1
DATE: RESIDENTIAL SITE DEVELOPMENT
LOCATION PLAN 6
CIVIL ENGINEER OWNER
TIN NO.: LOCATION: PHASE 2, BLK 2, LOT 12 MARIANVILLE, TIPANOY ILIGAN CITY ARCHITECTURAL
A
A B C D A B C D
8.00 7.00

2.00 6.00 1.00 6.00

1.65 1.20 3.15


1.65 1.20 3.15
2.00
1.25 1.60 0.65 1.00 1.50
PROPERTY LINE EXISTING FENCE
1.00

1.00
W1 W5 W1 W3 W5

FIREWALL

FIREWALL
3 3
T&B

1.50

1.50
elev.+0.25m
T&B
D4 D4
BED RM 1 BED RM 2

3.00
W1

HALLWAY
PROPERTY LINE EXISTING FENCE

B DINING B

1.05
4.00

W1
AREA
KITCHEN DN
AREA

2.50
D2 D2

FIREWALL

FIREWALL

1.45
elev.+0.30m

7.00

1.00
HALLWAY
10.00

2 2

5.50
D3

1.05
W4
LIVING

HALLWAY
AREA D2
3.00

3.00
PARKING TERRACE

1.95
AREA

3.00
BED RM 1
UP
FIREWALL

FIREWALL
D1
1 1

0.50
0.80

0.80
W1
2.00

ROOFLINE
W2 W1

PROPERTY LINE EXISTING FENCE

FIREWALL
ROAD LOT 4M WIDE
elev.0.00m

GROUND FLOOR PLAN (42.00sq.m) SECOND FLOOR PLAN (52.00sq.m)


SCALE 1:100MTS SCALE 1:100MTS

SIGNED BY: REG NO.: SEAL PROJECT TITLE: APPROVED BY: SHEET CONTENTS SHEET NO.
PTR NO.:
PLACE ISSUED:
PROPOSED 2-STOREY GROUND FLOOR PLAN A-2
DATE: RESIDENTIAL SECOND FLOOR PLAN
6
CIVIL ENGINEER OWNER
TIN NO.: LOCATION: PHASE 2, BLK 2, LOT 12 MARIANVILLE, TIPANOY ILIGAN CITY ARCHITECTURAL
CONCRETE STONE CONCRETE
PARAPET CLADDING PARAPET

A B C D D C B A
8.00 8.00

2.00 6.00 6.00 2.00

0.60 1.65 1.20 3.15 3.15 1.20 1.65 0.60

CONCRETE CONCRETE
0.50 0.50 CANOPY CANOPY
APEX OF ROOF APEX OF ROOF
1.00

1.00
TOP OF ROOF BEAM TOP OF ROOF BEAM

TYPICAL TYPICAL
3.00

3.00
ANALOK AWNING WINDOW
SLIDING WINDOW
4" THK. CHB WALL
PLASTER FINISHED
4" THK. CHB WALL
7.60

7.60
AND PAINT FINISHED
2ND. FLR.LINE PLASTER FINISHED 2ND. FLR.LINE
0.40

0.40
AND PAINT FINISHED
CEILING LINE CEILING LINE

6" THK. CHB


FIREWALL w/
3.30

3.30
2.90

2.90
6" THK. CHB WATER PROOFING
FIREWALL w/ INSIDE AND OUTSIDE
WATER PROOFING
INSIDE AND OUTSIDE
0.10

0.10
STONE
FIN. FLR.LINE FIN. FLR.LINE
CLADDING
NAT.GRND.LINE NAT.GRND.LINE
0.30

0.20

0.20

0.30
2" TUBULAR PIPE
HANDRAIL w/ 2" TUBULAR 0.90m PANEL DOOR TYPICAL
BALLUSTER COMPLETE w/ HEAVY ANALOK
DUTY ACCESSORIES SLIDING WINDOW

FRONT ELEVATION REAR ELEVATION


SCALE 1:100MTS SCALE 1:100MTS

SIGNED BY: REG NO.: SEAL PROJECT TITLE: APPROVED BY: SHEET CONTENTS SHEET NO.
PTR NO.:
PLACE ISSUED:
PROPOSED 2-STOREY FRONT ELEVATION A-3
DATE: RESIDENTIAL REAR ELEVATION
6
CIVIL ENGINEER OWNER
TIN NO.: LOCATION: PHASE 2, BLK 2, LOT 12 MARIANVILLE, TIPANOY ILIGAN CITY ARCHITECTURAL
CONCRETE STONE
PARAPET CLADDING

3 2 1 1 2 3
10.00 10.00

1.00 7.00 2.00 2.00 7.00 1.00

0.50 4.00 3.00 0.80 0.80 3.00 4.00 0.50


CONCRETE
CANOPY
APEX OF ROOF APEX OF ROOF

1.00
1.00

TOP OF ROOF BEAM TOP OF ROOF BEAM

6" THK. CHB


FIREWALL w/

3.00
3.00

TYPICAL
FIXED GLASS WATER PROOFING
INSIDE AND OUTSIDE

7.60
7.60

2ND. FLR.LINE 2ND. FLR.LINE


0.40

0.40
CEILING LINE CEILING LINE

6" THK. CHB


FIREWALL w/
3.30

3.30
WATER PROOFING

2.90
2.90

4" THK. CHB WALL INSIDE AND OUTSIDE


PLASTER FINISHED
AND PAINT FINISHED

0.10
0.10

FIN. FLR.LINE FIN. FLR.LINE


NAT.GRND.LINE NAT.GRND.LINE

0.30
0.30

0.20

TYPICAL 2" TUBULAR PIPE


ANALOK HANDRAIL w/ 2" TUBULAR
SLIDING WINDOW BALLUSTER

LEFT ELEVATION RIGHT ELEVATION


SCALE 1:100MTS SCALE 1:100MTS

SIGNED BY: REG NO.: SEAL PROJECT TITLE: APPROVED BY: SHEET CONTENTS SHEET NO.
PTR NO.:
PLACE ISSUED:
PROPOSED 2-STOREY RIGHT ELEVATION A-4
DATE: RESIDENTIAL LEFT ELEVATION
6
CIVIL ENGINEER OWNER
TIN NO.: LOCATION: PHASE 2, BLK 2, LOT 12 MARIANVILLE, TIPANOY ILIGAN CITY ARCHITECTURAL
A B C D 3 2 1
6.00 7.00

0.50 4.00 3.00 0.80


0.60 1.05 1.65 1.20 3.15

APEX OF ROOF APEX OF ROOF

1.00
1.00

SEE ROOF PLAN DETAILS SEE ROOF PLAN DETAILS

TOP OF ROOF BEAM TOP OF ROOF BEAM

3.00
3.00

7.60
7.60

2ND. FLR.LINE 2ND. FLR.LINE T&B BEDROOM

0.40
0.40

CEILING LINE CEILING LINE

1.60
3.30
3.30

2.90
2.90

FIN. FLR.LINE FIN. FLR.LINE T&B

NAT.GRND.LINE SEE FOUNDATION PLAN DETAILS NAT.GRND.LINE SEE FOUNDATION PLAN DETAILS

0.30
0.30

SECTION THRU "AA" SECTION THRU "BB"


SCALE 1:100MTS SCALE 1:100MTS

0.90 0.80 0.70 0.60 1.20 1.20 0.60 0.60 0.60

0.60

0.60
1.20

1.20

1.20
0.60
1.80
2.10

2.10

2.10

2.10

1.50
0.60 0.60 0.60 0.60

0.60
0.90

0.90

0.90
0.30
D1 D2 D3 D4 W1 W2 W3 W4 W5

0.90mx2.10m, PANEL DOOR 0.80mx2.10m, PANEL DOOR 0.70mx2.10m, PANEL DOOR 0.60mx2.10m, PVC DOOR 1.20mx2.40m, ANALOK 1.20mx2.40m, ANALOK 0.60mx1.80m, AWNING 1.20mx0.60m, ANALOK 0.60mx0.60m, AWNING
ON STANDARD WOODEN JAMB ON STANDARD WOODEN JAMB ON STANDARD WOODEN JAMB ON STANDARD PVC JAMB SLIDING WINDOW ON CORNER WINDOW ON WINDOW ON STANDARD FIXED WINDOW ON WINDOW ON STANDARD
100mmx50mm WITH COMPLETE 100mmx50mm WITH COMPLETE 100mmx50mm WITH COMPLETE 100mmx50mm WITH COMPLETE STANDARD ANALOK ALUMINUM STANDARD ANALOK ALUMINUM ANALOK ALUMINUM STANDARD ANALOK ALUMINUM ANALOK ALUMINUM
HEAVY DUTY ACCESSORIES HEAVY DUTY ACCESSORIES HEAVY DUTY ACCESSORIES HEAVY DUTY ACCESSORIES FRAME WITH COMPLETE FRAME WITH COMPLETE FRAME WITH COMPLETE FRAME WITH COMPLETE FRAME WITH COMPLETE
AND DOOR KNOB AND DOOR KNOB AND DOOR KNOB AND DOOR KNOB ACCESSORIES AND SEALANT ACCESSORIES AND SEALANT ACCESSORIES AND SEALANT ACCESSORIES AND SEALANT ACCESSORIES AND SEALANT

SCHEDULE OF DOORS AND WINDOWS


SCALE 1:40MTS

SIGNED BY: REG NO.: SEAL PROJECT TITLE: APPROVED BY: SHEET CONTENTS SHEET NO.
PTR NO.:
PLACE ISSUED:
PROPOSED 2-STOREY SCHEDULE OF DOORS & WINDOWS A-5
DATE: RESIDENTIAL SECTIONS
6
CIVIL ENGINEER OWNER
TIN NO.: LOCATION: PHASE 2, BLK 2, LOT 12 MARIANVILLE, TIPANOY ILIGAN CITY ARCHITECTURAL
1 1
4" THK. HARDIFLEX CEILING w/ METAL 4" THK. HARDIFLEX CEILING w/ METAL
FURRING FRAMING (EXTERIOR FURRING FRAMING (EXTERIOR
& INTERIOR CEILING) & INTERIOR CEILING)

FIREWALL

FIREWALL
FIREWALL

FIREWALL
FIREWALL

FIREWALL
elev.0.00m

WOODEN MOULDING WOODEN MOULDING


(EXTERIOR & INTERIOR (EXTERIOR & INTERIOR
CEILING) CEILING)

GROUND FLOOR REFLECTED CEILING PLAN SECOND FLOOR REFLECTED CEILING PLAN
SCALE 1:75MTS SCALE 1:75MTS

SIGNED BY: REG NO.: SEAL PROJECT TITLE: APPROVED BY: SHEET CONTENTS SHEET NO.
PTR NO.:
PLACE ISSUED:
PROPOSED 2-STOREY GROUND FLOOR REFLECTED CEILING PLAN A-6
DATE: RESIDENTIAL 2ND FLOOR REFLECTED CEILING PLAN
6
CIVIL ENGINEER OWNER
TIN NO.: LOCATION: PHASE 2, BLK 2, LOT 12 MARIANVILLE, TIPANOY ILIGAN CITY ARCHITECTURAL
LONGSPAN ROOFING
ON 2"X6"X1.5mm THK.
C-PURLINS RAFTER
AND 2"X3" TUBULAR STEEL

A B C D A B C D A B C D
6.00 6.00 12mmØ 7.00
PLAIN ROUND
BAR SAGROD 1.00 6.00
1.65 1.20 3.15 1.65 1.20 3.15
1.65 1.20 3.15

C1/F1 WF1 C1/F1 WF1 C1/F2


RB RB
3 3 CB B1 B1
3 INSIDE GUTTER INSIDE GUTTER
250mm THK.
ON FILL
WF1 WF2 B2 S1 S1 S1
B1 B2 B1

TUBULAR RAFTER

TUBULAR RAFTER

TUBULAR RAFTER
2"X6"X1.5mm THK.

2"X6"X1.5mm THK.

2"X6"X1.5mm THK.
300mm THK. ON FILL W/
100mm THK. SLAB ON
GRADE W/ 10mmØ WF1 CB B1 B1

4.00
4.00

4.00
WF1 RB RB
DEFORMED STEEL
BARS MATTING S1
SPCD. @ 600mm BOTH WF2

INSIDE AND OUTSIDE


WAYS

WATER PROOFING
B2 S1 S1 B2 S1 B1

1.45

FIREWALL w/
6" THK. CHB
B1

7.00
STAIR
7.00

7.00
WELL RB
C1/F1 C1/F1 C1/F2 CB B1
2 2 2
RB
WF1 B2 B2

1.05

TUBULAR RAFTER

TUBULAR RAFTER
2"X6"X1.5mm THK.

2"X6"X1.5mm THK.
3.00
RB RB
3.00

3.00
WF1 WF2 B2 S1 B1 S1 B1 S1 B1
S1 B1

RB
C1/F1 C1/F2 B1 B1
1
1 1

0.80
0.50

S1

1.00
WF1 CB CB CB S1 CB
B2 4" THK CHB
B2 CONCRETE
PARAPET
0.15 WITH WATER 2"X3" C-PURLINS
PROFFING SPACE @ 700MM O.C .

FOUNDATION PLAN SECOND FLOOR BEAM FRAMING PLAN ROOF FRAMING PLAN DETAILS
SCALE 1:100MTS
SCALE 1:100MTS SCALE 1:100MTS

SIGNED BY: REG NO.: SEAL PROJECT TITLE: APPROVED BY: SHEET CONTENTS SHEET NO.
PTR NO.:
PLACE ISSUED:
PROPOSED 2-STOREY FOUNDATION PLAN S-1
DATE: RESIDENTIAL 2ND FLR FRAMING PLAN
ROOF FRAMING PLAN 5
CIVIL ENGINEER OWNER
TIN NO.: LOCATION: PHASE 2, BLK 2, LOT 12 MARIANVILLE, TIPANOY ILIGAN CITY STRUCTURAL
10MM Ø DSB EXTRA BAR SPCD
10MM Ø DSB CONTINUOUS @ 150MM O.C. 10MM Ø DSB CONTINUOUS
TOP BAR SPCD @ 150MM O.C. TOP BAR SPCD @150MM O.C.

L L 10MM Ø DSB EXTRA


BAR SPCD @ 150MM
100mm THK. O.C.
CONC. SLAB
L/4 L/4 L/4 L/4

T=100mm
RC COLUMN
CONCRETE ENDWALL
10MM Ø DSB CONTINUOUS BOTTOM 10MM Ø DSB CONTINUOUS BOTTOM RC COLUMN
PARAPET FLASHING
BAR SPCD @ 150MM O.C. BAR SPCD @ 150MM O.C.
WITH WATER
PROFFING A B C D
7.00 L/4 L/4 L/4 L/4

1.00 6.00

1.65 1.20 3.15

L/4

L/4
3
3.55

L/4

L/4
WATER PROOFING INSIDE AND OUTSIDE
6" THK. CHB FIREWALL w/
7.00

L/4 L/4 L/4 L/4


0.45

2
SLAB (S1) DETAILS
SCALE NTS

STAINLESS REC
3.00

TUBE 2" HANDRAIL

0.90
RAILINGS

1
0.80

G.1 REC TUBE


1.10

1-1/2" B1

10MMØ DSB

CONCRETE 0.25
10MMØ REBAR

3.20
ROOFING WITH
WATER PROOFING LONGSPAN ROOFING
AND SLOPE AT 1% ON 2"X6"X1.5mm THK.

1.01
WITH 12mmØ DSB

0.20
C-PURLINS RAFTER
SPCD.@0.20m C.C.O.C AND 2"X3" TUBULAR STEEL 10MM Ø CROSS
BAR @ 0.30M O.C
5- 16MM Ø LONGITUDINAL
ROOF PLAN FFL. FFL. BAR

0.20 0.10
SCALE 1:100MTS

5- 12MM Ø @ B.W

0.75

CONCRETE STAIR DETAILS


SCALE NTS

SIGNED BY: REG NO.: SEAL PROJECT TITLE: APPROVED BY: SHEET CONTENTS SHEET NO.
PTR NO.:
PLACE ISSUED:
PROPOSED 2-STOREY ROOF PLAN S-2
DATE: RESIDENTIAL SLAB DETAILS
CONC. STAIR DETAILS 5
CIVIL ENGINEER OWNER
TIN NO.: LOCATION: PHASE 2, BLK 2, LOT 12 MARIANVILLE, TIPANOY ILIGAN CITY STRUCTURAL
8 - 16MM Ø DSB VERTICAL
BARS W/ 10MM STIRRUP TIES
SPCD @ 10 - 0.05M , 10 -
0.10M, REST @ 0.20M. O.C

FFL. FFL.
0.30

0.30
NGL. WELL-COMPACTED NGL.
GRAVEL BASE COURSE
1.40

1.40
0.40

0.40
150MM THK. GRAVEL BED

1.4 1.40
0.30 0.30

10 - 16MMØ DSB 10 - 16MMØ DSB


REBARS @ B.W REBARS @ B.W

8 - 16MM Ø DSB 8 - 16MM Ø DSB


0.30

0.30
1.40

1.40
VERTICAL BARS W/ VERTICAL BARS W/
10MM STIRRUP TIES 10MM STIRRUP TIES
SPCD @ 10 - 0.05M , SPCD @ 10 - 0.05M ,
10 - 0.10M, REST @ 10 - 0.10M, REST @
0.20M. O.C 0.20M. O.C

C1F1 SECTION DETAILS C1F2 SECTION DETAILS


SCALE 1:30MTS SCALE 1:30MTS

SIGNED BY: REG NO.: SEAL PROJECT TITLE: APPROVED BY: SHEET CONTENTS SHEET NO.
PTR NO.:
PLACE ISSUED:
PROPOSED 2-STOREY C1F1 DETAILS S-3
DATE: RESIDENTIAL C1F2 DETAILS
5
CIVIL ENGINEER OWNER
TIN NO.: LOCATION: PHASE 2, BLK 2, LOT 12 MARIANVILLE, TIPANOY ILIGAN CITY STRUCTURAL
4" THK. CHB WALL W/ 10MM
Ø VERT. BARS SPCD @
0.60M O.C, W/ 10MM Ø HOR. 0.20 0.20 0.20 0.20
BARS @ EVERY 3RD LAYER
OF CHB.
6-16MMØ . TOP BARS 4-16MMØ CONT. 5-16MMØ . TOP BARS 3-16MMØ CONT.
TOP BARS

0.40

0.40

0.30

0.30
TOP BARS
416MMØ CONT. 6 -16MMØ DSB 3-16MMØ CONT. 5 -16MMØ DSB
FFL. FFL. BOT. BARS BOT. BARS BOT. BARS BOT. BARS

0.30

0.30
SUPPORT MIDSPAN SUPPORT MIDSPAN
NGL. NGL.

B1 DETAILS B2 DETAILS

0.40

0.40
SCALE 1:25MTS SCALE 1:25MTS

0.20

0.20
0.20 0.20 0.20 0.20

3 - 12MMØ LONG 5-16MMØ . TOP BARS 3-16MMØ CONT. 3-16MMØ .CONT. TOP BARS 2-16MMØ CONT.

0.30

0.30
TOP BARS

0.40

0.40
BARS W/ 10MM Ø TOP BARS
REBAR TIES SPCD @ 3-16MMØ CONT. 3 -16MMØ DSB
0.40 0.40 3-16MMØ CONT. 5 -16MMØ DSB
0.30M O.C BOT. BARS BOT. BARS
BOT. BARS BOT. BARS
MIDSPAN SUPPORT MIDSPAN

CB DETAILS RB DETAILS
WF1 DETAILS WF2 DETAILS SCALE 1:25MTS SCALE 1:25MTS

SCALE 1:20MTS SCALE 1:20MTS

L1 L2

L1/4 L1/4 L2/4 L2/4

EXTRA CONTINUOUS STIFFENER EXTRA


TOP BARS TOP BARS BAR TOP BARS
RC COLUMN
SUPPORT RC COLUMN
(TYP.) SUPPORT (TYP.)

EXTRA BOTTOM EXTRA BOTTOM


BARS BARS
L1/5 L1/5 L2/5 L2/5

CONTINUOUS CONTINUOUS
BOTTOM BOTTOM
BARS BARS
STIRRUP: USE 10mm Ø DSB SPCD @ 5 -50MM, 5 - 100MM REST 150MM O.C

TYPICAL BEAM DETAILS

SIGNED BY: REG NO.: SEAL PROJECT TITLE: APPROVED BY: SHEET CONTENTS SHEET NO.
PTR NO.:
PLACE ISSUED:
PROPOSED 2-STOREY BEAM DETAILS S-4
DATE: RESIDENTIAL TYPICAL BEAM REINFORCEMENT
DETAILS 5
CIVIL ENGINEER OWNER
TIN NO.: LOCATION: PHASE 2, BLK 2, LOT 12 MARIANVILLE, TIPANOY ILIGAN CITY STRUCTURAL
SPANISH LONGSPAN ROOFING 12mmØ PLAIN
2"X3" C-PURLINS
INSIDE ON 2"X6"X1.5mm THK. ROUND BAR
GUTTER TUBULAR RAFTER SAGROD
AND 2"X3" TUBULAR STEEL 0.10
7.46
4" THK CHB
CONCRETE 0.28
7.69
PARAPET
0.83 0.83
WITH WATER 0.83 0.83
0.83 0.83
PROFFING 0.83 0.83
0.60 0.83

TER
2"X6"X1.5mm THK. TUBULAR RAF
TER
1.00

2"X6"X1.5mm THK. TUBULAR RAF ROOF


ROOF BEAM

0.23
BEAM
0.40

0.15
0.20
0.30
CONCRETE CONCRETE CONCRETE
CEILING LINE
COLUMN COLUMN COLUMN
CONCRETE
CORBEL

4"Ø PVC PIPE


DOWNSPOUT

STEEL RAFTER DETAILS 0.15


2"X3" TUBULAR
SCALE 1:30MTS STEEL PURLINS

0.20
SCREEN LONGSPAN ROOFING
ON 2"X6"X1.5mm THK.
0.15 C-PURLINS RAFTER
AND 2"X3" TUBULAR STEEL

0.40

0.23
2"X6"X1.5mm THK.
C-PURLINS RAFTER
GAUGE 18 SPANISH
INSIDE GUTTER

0.20
CONCRETE
ROOF BEAM
CONCRETE
CORBEL WITH
12mmØ DSB
VERTICAL &
HORIZONTAL BARS

4"Ø PVC PIPE


DOWNSPOUT
GUTTER DETAILS
SCALE 1:15MTS

SIGNED BY: REG NO.: SEAL PROJECT TITLE: APPROVED BY: SHEET CONTENTS SHEET NO.
PTR NO.:
PLACE ISSUED:
PROPOSED 2-STOREY TYPICAL RAFTER DETAILS S-5
DATE: RESIDENTIAL GUTETR DETAILS
5
CIVIL ENGINEER OWNER
TIN NO.: LOCATION: PHASE 2, BLK 2, LOT 12 MARIANVILLE, TIPANOY ILIGAN CITY STRUCTURAL
10mmØ BAR 3 - 10mmØ (E.W)
HANDLE

SPECIFICATION: LEGEND: 0.25


0.60
0.10 0.20
THIS SITE
1. GRADES OF HORIZON PIPINGS Phase 2, Block 2, Lot 12
WC - WATER CLOSET
RUN ALL HORIZONTAL IN PERPECT ALIGNMENT AND AT A FORM GRADE NOT LESS
THAN TWO PERCENT (2%) F - FAUCET

KS - KITCHEN SINK

0.10
2. CHANGE IN DIRECTION:
ALL CHANGE IN DIRECTION SHALL BE MADE BY APPROPRIATE USE OF FORY-FIVE FD - FLOOR DRAIN
DEGREES (45°) WYES, LING SWEEP
QUARTER BEND, SIXTH-EIGTH OR SIXTEENTH BEND. WHEN THE CHANGE OF FLOW IS LAV - LAVATORY 0.05 0.05 0.05 0.05
FROM HORIZONTAL TO VERTICAL A
CO - CLEAN OUT
SINGLE 1/8 BEND COMBINATION MAYBE USED ON VERTICAL STACKS AND SHORT
QUARTER BENDS MAYBE USED ON WASTE VTR - VENT THRU ROOF MANHOLE COVER DETAILS
3. PROHIBITED FITTINGS MH - MANHOLE
SCALE: NTS.
NO DOUBLE HUB OR TEE BRANCH SHALL BE USED ON HORIZONTAL AND WASTE LINES,
THE DRILLINGS AND TAPPING CB - CATCH BASIN 0.50
OF HOUSE DRAIN, WASTE OR BEND PIPES AND USED OF SUBTLE HUB AND BEND ARE
PROHIBITED. GT - GREASE TRAP

GV - GATE VALVE
4. PIPE CLEAN-OUTS
CLEAN-OUTS ARE REQUIRED UNDER THE FOLLOWING CONDITIONS; DS - DOWN SPOUT

0.50
a) EVERY CHANGE OF HORIZONTAL DIRECTION EXCEEDING TWENTY-TWO AND MANHOLE
ONE-HALF DEGREES (22 1/2°). SV - SEPTIC VAULT
b) ONE AND ONE-HALF METERS (1.50m) INSIDE THE PROPERTY LINE BEFORE THE
WM - WATER METER
HOUSE DRAINAGE CONNECTION.
c) EVERY FIFTEEN METERS (15.00m) IN HORIZONTAL RUN OF PIPES. SH - SHOWER HEAD
d) AT THE END OF ANY HORIZONTAL PIPE LINES.

5. THE DIGESTION CHAMBER OF SEPTIC VAULT MUST BE WATERPROOFED.


LOCATION PLAN

0.10
6. NOT LESS THAN 0.30 METER OF AIR SPACE MUST BE LEFT BETWEEN THE TOP OF
SEWAGE AND THE UNDER PART OF
VAULT ROOF SLAB. 3.0

VARIES
7. NO SEPTIC VAULT SHALL BE CONSTRUCTED UNDER THE BUILDING. PVC PIPE 1.50 0.75 0.75
0.15
8. ALL PLUMBING WORKS SHALL BE UNDER THE SUPERVISION OF A LICENSED MASTER
PVC PIPE 4"Ø INLET

PLUMBER AND A LICENSED PLUMBING


CONTRACTOR.
CO CO CO
OUTLET 4"Ø
0.60
0.50
10mmØ BED BARS
SPCD. @ 0.20 O.C. B.W.

0.60

2.00
REMOVABLE
CATCH BASIN DETAILS MH MH MH
BRASS SCALE: NTS. A
STRAINER STRAINER BODY
FINISHED FLOOR LINE CLEAN-OUT PLUG
BRASS NICKEL
0.60 0.60

0.10
COVER SEAL FINISHED FLOOR LINE
0.10 0.15
0.20 0.20
TO MAIN LINE
PVC CONNECTOR (SIZE AS INDICATED IN PLAN)
SUITE DRAIN & 0.15
P-TRAP SIZE
90° ELBOW 0.15 PLAN
PVC DEEP SEAL P-TRAP CO MH CO MH CO MH CO NGL.
0.20

0.20
0.60

COVER COVER

0.22
CLEANING EYE
FLUSH TYPE AIR SPACE
4"Ø 4"Ø
OUTLET 2" Ø
CLEAN-OUT DETAIL
FLOOR DRAIN DETAIL INLET 4"Ø OUTLET 4"Ø
DIGESTIVE LEACHING LEACHING
2" 4"Ø
0.10 0.10 CHAMBER CHAMBER CHAMBER
Ø

2.00

2.00
100mmØ SOIL STACK
COUNTER SUNK SCREW PLUG
100mmØ PVC CLEANOUT COUNTER SUNK
1.00 10MM Ø DSB SPCD
SCREW PLUG 150mm THK. CHB W/ 10mmm
@ 200MM O.C Ø VERT & HOR. BARS
0.10

100mmØ CLEANOUT 0.55 0.45 SPCD @ 0.06m O.C.


100mmØ PVC 1/8 BEND
100mmØ WYEE
2% SLOPE CONNECTION
NGL.
100mmØ PVC PIPE
100mmØ 1/8 BEND
0.15

100mmØ PVC 1/8 BEND

0.30

0.30
AIR SPACE
OUTLET 2" Ø
INLET 2" Ø
STANDARD CONNECTION VERTICAL TO HORIZONTAL
0.70

CLEAN-OUT DETAIL SOIL PIPE CONNECTION 10MM Ø DSB SPCD


@ 200MM O.C 0.40 0.40 0.40 0.40

100mm THK CONC. 100mm THK CONC.


CONC. RC
0.10

STANDARD SOIL PIPE CONNECTIONS SLAB W/ 1% SLOPE &


10mm Ø BEDBARS @
SLAB W/ 1% SLOPE &
10mm Ø BEDBARS @
0.10

SCALE: NTS. 0.30m. O.C. B.W 0.30m. O.C. B.W

GREASE TRAP DETAILS SEPTIC TANK DETAILS


SCALE: NTS. SCALE: NTS.

SIGNED BY: REG NO.: SEAL PROJECT TITLE: APPROVED BY: SHEET CONTENTS SHEET NO.
PTR NO.:
P-1
SPECIFICATION /LEGEND

PLACE ISSUED: PROPOSED 2-STOREY LOCATION PLAN/


SEPTIC VAULT SECTION DETAILS

DATE: RESIDENTIAL
STANDARD SOIL PIPE CONNECTIONS
GREASE TRAP DETAILS
CATCH BASIN DETAILS
4
MASTER PLUMBER OWNER MANHOLE COVER DETAILS
TIN NO.: LOCATION: PHASE 2, BLK 2, LOT 12 MARIANVILLE, TIPANOY ILIGAN CITY PLUMBING
PROPERTY LINE EXISTING FENCE

INLET 4"Ø PVC CO CO


SANITARY PIPE TO 2ND TO 2ND TO GRND.FLR. TO GRND.FLR.

FIREWALL

FIREWALL
FLR. FLR.
MH
VTR LAV VTR S/F
FD FD
SEPTIC T&B S/F LAV
WC
T&B
TANK
WC CO
MH BED RM 1 BED RM 2

HALLWAY
PROPERTY LINE EXISTING FENCE

DINING
AREA KS
KITCHEN CO DN
AREA

FIREWALL

FIREWALL
HALLWAY
SANITARY PIPE

LIVING
4"Ø PVC

HALLWAY
AREA

PARKING TERRACE
AREA BED RM 1
UP

FIREWALL

FIREWALL
ROOFLINE
TO MAIN elev.0.00m
CANAL

GROUND FLOOR SANITARY LAYOUT PLAN SECOND FLOOR SANITARY LAYOUT PLAN
SCALE 1:100MTS SCALE 1:100MTS

SIGNED BY: REG NO.: SEAL PROJECT TITLE: APPROVED BY: SHEET CONTENTS SHEET NO.
PTR NO.:
PLACE ISSUED:
PROPOSED 2-STOREY GROUND FLOOR SANITARY LINE LAYOUT PLAN
SECOND FLOOR SANITARY LINE LAYOUT PLAN
P-2
DATE: RESIDENTIAL 4
MASTER PLUMBER OWNER
TIN NO.: LOCATION: PHASE 2, BLK 2, LOT 12 MARIANVILLE, TIPANOY ILIGAN CITY PLUMBING
1"Ø G.I. PIPE SUPREME TO 2ND

FIREWALL

FIREWALL
FLR.

LAV
F F S/F
S/F
1"Ø G.I. PIPE SUPREME

LAV T&B
T&B F
WC BED RM 1 BED RM 2 WC
F F

HALLWAY
PROPERTY LINE EXISTING FENCE

DINING
AREA KS F
KITCHEN DN
AREA

FIREWALL

FIREWALL
HALLWAY
F

LIVING

HALLWAY
AREA

PARKING TERRACE
AREA S3
BED RM 1
UP

FIREWALL

FIREWALL
CV

S1

M
GV
ROOFLINE
elev.0.00m
CONNECT TO
STREET WATER LINE

GROUND FLOOR WATER LAYOUT PLAN SECOND FLOOR WATER LAYOUT PLAN
SCALE 1:100MTS SCALE 1:100MTS

SIGNED BY: REG NO.: SEAL PROJECT TITLE: APPROVED BY: SHEET CONTENTS SHEET NO.
PTR NO.:
PLACE ISSUED:
PROPOSED 2-STOREY GROUND FLOOR WATER LINE LAYOUT PLAN
SECOND FLOOR WATER LINE LAYOUT PLAN
P-3
DATE: RESIDENTIAL 4
MASTER PLUMBER OWNER
TIN NO.: LOCATION: PHASE 2, BLK 2, LOT 12 MARIANVILLE, TIPANOY ILIGAN CITY PLUMBING
ER
UTT
F G
R OO SH
O
E
SID
IN
ER F

SANITARY PIPE
TT FIR
GU

4"Ø PVC
F F EW
O A
E RO T&B LL
ID F LAV
INS WC

SANITARY PIPE
F FIR

4"Ø PVC
DN EW
HA AL
LL L
FIR 2 WA
M Y
DR
. EW
LR
SANITARY PIPE

.F
ND S/F ALL BE
4"Ø PVC

GR
TO FD T&B FIR
LR
. V
LA WC 1 S3 EW
ND
.F
RM 1 A
GR R FIR
BE
D RM LL
TO
VT CO H DN EW Y D
WA HA BE
AL AL LL
2 LW
AY
L HA LL
WA
M
DR Y
BE
FIR A CE
1

1"Ø G.I. PIPE SUPREME


RM
EW RR
1 AL TE
BE
D RM L
W AY ED
LL HA B O
HA LL
WA SH
Y E
F LIN
ROO
C E FIR
RA EW F
TE
R
N CE AL
PRESSURE FE F L
SANITARY PIPE

G V
TANK W/ IN LA F
IST WC
4"Ø PVC

D
AUTOMATIC 2N .
X ETO FLR &B
PRESSURE EE E M T F F FIR
SANITARY PIPE

IN
E SWITCH IN PR KS EW
L
YL U
4"Ø PVC

OF S N AL
RO RT PIP
E
HE A L
PE I. C E
COD FIRE PR
O G. KIT AR
E 1"Ø
SANITARY PIPE

NC 2N R. W
FE TO FL FD ALL KS
4"Ø PVC

G LA
V S/F C INGA FIR
IST
IN W DINARE EW
X
D
COTO 2NFLR. T &B ING A UP AL
EE R FIR LIVARE L
IN IPE VT O EW ME
T YL C
PV Y P E N C AL UP
RE
E R Ø
4" ITA R
CH EA L ES
R OP T AN KIT AR
CE N IP
P S I. P
N LE FE G. F
I G
1"Ø
INGA
TIN
I N FIR XIS G 00
m
D ARE EW EE KINEA .0.
MH IC ING A UP AL IN R
PA AR ele
v
PT K
SE TAN
LIVARE L YL
RT
MH
E E
OP
E PR CV T TOR LIN
C E
NC
FE M NEWAT
GV N
G
IN
S1

COEET
R
ST
T
XIS G .00
m
KINEA
E
PIP v.0
E
E R ele
PA AR
Y
LIN R V C
ITA P Y
AN 4"Ø RT
E S
OP
P R WATER LAYOUT ISOMETRIC VIEW
SCALE NTS
IN SANITARY LAYOUT ISOMETRIC VIEW
MANAL SCALE NTS
O
T CA

SIGNED BY: REG NO.: SEAL PROJECT TITLE: APPROVED BY: SHEET CONTENTS SHEET NO.
PTR NO.:
PLACE ISSUED:
PROPOSED 2-STOREY ISOMETRIC VIEW P-4
DATE: RESIDENTIAL 4
MASTER PLUMBER OWNER
TIN NO.: LOCATION: PHASE 2, BLK 2, LOT 12 MARIANVILLE, TIPANOY ILIGAN CITY PLUMBING
SPECIFICATION:
LEGEND: THIS SITE
1. ALL ELECTRICAL WORKS SHALL COMPLY IN ACCORDANCE WITH 2 - 1C - 22mm² THW WIRE
Phase 2, Block 2, Lot 12
THESE PLANS AND SPECIFICATIONS. THE APPLICABLE PROVISIONS
OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE PIN LIGHT
(PEC).
THE RULES AND REGULATION OF THE LOCAL ENFORCING AUTHORITY
CONVENIECE OUTLET M
AND THE REQUIREMENTS OF THE LOCAL, POWER COMPANY. R REF./RANGE OUTLET
THE ELECTRICAL WORKS SHALL BE UNDER IMMEDIATE SUPERVISION
FLOURESCENT OUTLET 100 AT
OF A DULY REGISTERED ELECTRICAL ENGINEER. MAIN CB
SWITCH LINE
2.THE ELECTRICAL SERVICE POWER IS 1 - PHASE, 2- WIRE, 230 V AC, 60 Hz

3.WIRING METHOD SHALL BE AS FOLLOWS:


LIGHTING RUN WIRE
C1 15A 15 A C2
A. FEEDERS AND RISERS - INTERMEDIATE METLLIC CODUIT CONVENIENCE OUTLE RUN WIRE
B.LIGHTING POWER RECEPTACLE - POLYVINYL CHLORIDE C1 CIRCUIT HOMERUN C3 15A 15 A C4
CONDUIT
BRANCH CKT., & AUXILIARY SCH. 40 M KILOWATTHOUR METER

CONNECTED WIRE
C5 20A 20 A C6
4.ALL WIRES SHALL BE COPPER AND THERMOPLASTIC INSULATED TYPE
"THW" UNLESS OTHERWISE INDICATED IN THE PLAN. THE MINIMUM SIZE
OF WIRE FOR POWER AND LIGHTING CIRCUIT HOMERUN SHALL BE 3.5mm²
NOT CONNECTED WIRE
C7 30A 30 A C8
AND INSULATED FOR 600 VOLTS. SMALLEST RACEWAY SHALL BE 15mmØ SERVICE ENTRANCE DROP WIRE
TRADE/NOMINAL SIZE.
PANEL BOARD C9 30A 30 A C10
5.ALL OUTLET BOXES SHALL BE PVC.
S THUMBLER SWITCH
6.ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND APPROVED
TYPE FOR THE PARTICULAR LOCATION AND PURPOSED OF USAGE. AIRCON
GROUND

7.GROUNDING SYSTEM SHALL BE PROVIDED TO ALL LIGHTING AND POWER


CIRCUIT AS PER PHILIPPINE ELECTRICAL CODE REQUIREMENT.

SINGLE LINE DIAGRAM LOCATION PLAN


8.MOUNTING HEIGHT OF WIRING DEVICES SHALL BE AS FOLLOWS:

A. LIGHT SWITCH - 1.20 M ABOVE FINISH FLOOR SCALE: NTS.

B.CONVENIENCE OUTLET - 0.30 M ABOVE FINISH FLOOR

C. PANEL BOARD - 1.50 M ABOVE FINISH FLOOR


SCHEDULE OF LOADS
CABLE WIRE SIZE GROUND GREEN CONDUIT DIA.
CKT. NO. LOAD DESCRIPTION SPO L.O. C.O. WATTS VOLTS AMPERE/CKT. PROTECTION/CKT. THHN CABLE SIZE THHN .RSC
2
2-1C - 22 MM THW.WIRE C1 LIGHTING OUTLET 12 1200 220 5.45 A 15 A 2 - 1C - 3.5 MM² THW WIRE 1 - 1C - 2.0 MM² 20MM dia.
SERVICE WIRE
C2 LIGHTING OUTLET 11 1100 220 5A 15 A 2- 1C - 3.5 MM² THW WIRE 1 - 1C - 2.0 MM² 20MM dia.

C3 LIGHTING OUTLET 13 1300 220 5.91A 15 A 2 - 1C -3.5 MM² THW WIRE 1 - 1C - 2.0 MM² 20MM dia.
SECONDARY RACK
C4 LIGHTING OUTLET 13 1300 220 5.91A 15 A 2- 1C - 3.5 MM² THW WIRE 1 - 1C - 2.0 MM² 20MM dia.
DROP WIRE C5 CONVINIENCE OUTLET 7 220 11.45 A 20 A 2 - 1C - 5.5 MM² THW WIRE 20MM dia.
2520 1 - 1C - 2.0 MM²
CABLE TERMINAL
C6 CONVINIENCE OUTLET 10 3600 220 16.36 A 20 A 2- 1C - 5.5 MM² THW WIRE 1 - 1C - 2.0 MM² 20MM dia.

C7 SPECIAL PURPOSE OUTLET 1 1500 220 6.82 A 30 A 2 - 1C - 5.5 MM² THW WIRE 1 - 1C - 2.0 MM² 20MM dia.

C8 SPECIAL PURPOSE OUTLET 1 1500 220 6.82 A 30 A 2- 1C - 5.5 MM² THW WIRE 1 - 1C - 2.0 MM² 20MM dia.

C9 SPECIAL PURPOSE OUTLET 1 1500 220 6.82 A 30 A 2 - 1C - 5.5 MM² THW WIRE 1 - 1C - 2.0 MM² 20MM dia.

C10 SPECIAL PURPOSE OUTLET 1 1500 220 6.82 A 30 A 2- 1C - 5.5 MM² THW WIRE 1 - 1C - 2.0 MM² 20MM dia.

TOTAL 4 49 17 17,020 220 77.36 A 100 A 2 - 1C - 22 MM² THW WIRE 1 - 1C - 2.0 MM² 25MM dia.

M KILOWATTHOUR METER
PANEL
BOARD PANEL BOARD FOR MAIN FEEDER SIZE:
A. SUB-CONNECTED LOADS OF TWO STOREY APARTMENT BUILDING AT 125% = 96.7 AMPS
TO TEL. SET
1.80 m
POLE
1 TOTAL CONNECTED LOADS KW 17.02 USE 2-1C-22 mmsq THW with cable ampacities of 110 AMPS
2 CONNECTED KVA 21.275 Ground Cable Use: 1-1c-3.5 MMSQ THHN
3 % DEMAND FACTOR % 80 FOR MAIN CIRCUIT BREAKER PROTECTION:
4 DEMAND KVA 17.02 AT 150% = 116.04 AMPS
1-1C-2.0MM
2
THHN GREEN
5 DEMAND AMPERES AMPS 77.36 USE: 100 AMPERES CIRCUIT BREAKER 2P BOLTED TYPE, 65 KAIC SUB - MAIN PROTECTION
COLOR

%DEMAND FACTOR = DEMAND LOAD KVA/ CONNECTED KVA X 100%


DEMAND LOAD KVA = CONNECTED KVA / DIVERSITY FACTOR 1.25 FOR 100% D.F
1/2" X 5" GRD. ROD. 21.275 KVA / 1.25 =17.02 KVA
S0 % DEMAND FACTOR = 17.02 KVA / 21.275 X 100% = 80%
TELEPHONE & ELECTRICAL DEMAND AMPERES = 21.275 KVA X 0.8 / 0.22 =77.36 AMPS
GROUND CABLE SIZE:
SERVICE ENTRANCE DETAIL 77.36 AMPS. AT 20% = 15.472 AMPS
SCALE: NTS. 1-1C-3.5 MMSQ. (12 AWG)

SIGNED BY: REG NO.: SEAL PROJECT TITLE: APPROVED BY: SHEET CONTENTS SHEET NO.
PTR NO.:
E-1
SPECIFICATIONS

PLACE ISSUED: PROPOSED 2-STOREY LEGEND/ LOCATION PLAN


SCHEDULE OF LOADS

DATE: RESIDENTIAL
SINGLE LINE DIAGRAM
TELEPHONE AND ELECTRICAL SERVICE
ENTRANCE DETAILS
3
ELECTRICAL ENGINEER OWNER
TIN NO.: LOCATION: PHASE 2, BLK 2, LOT 12 MARIANVILLE, TIPANOY ILIGAN CITY ELECTRICAL
PROPERTY LINE EXISTING FENCE

FIREWALL

FIREWALL
S1 T&B S1 T&B
CKT.3
CKT.1
BED RM 1 BED RM 2

HALLWAY
PROPERTY LINE EXISTING FENCE

S3
DINING
AREA
KITCHEN DN
AREA
S2 S2

FIREWALL

FIREWALL
S3
HALLWAY
CKT.2 S3
S3 S3
LIVING

HALLWAY
AREA S3

PARKING TERRACE
AREA BED RM 1
UP

FIREWALL

FIREWALL
S3 S2 S2

CKT.4
ROOFLINE
elev.0.00m

GROUND FLOOR LIGHTING LAYOUT PLAN SECOND FLOOR LIGHTING LAYOUT PLAN
SCALE 1:100MTS SCALE 1:100MTS

PROPERTY LINE EXISTING FENCE


SIGNED BY: REG NO.: SEAL PROJECT TITLE: APPROVED BY: SHEET CONTENTS SHEET NO.
PTR NO.:
PLACE ISSUED:
PROPOSED 2-STOREY GROUND FLOOR LIGHTING LAYOUT PLAN
SECOND FLOOR LIGHTING LAYOUT PLAN
E-2
DATE:
RESIDENTIAL 3
ELECTRICAL ENGINEER OWNER
TIN NO.: LOCATION: PHASE 2, BLK 2, LOT 12 MARIANVILLE, TIPANOY ILIGAN CITY ELECTRICAL
PROPERTY LINE EXISTING FENCE

FIREWALL

FIREWALL
T&B T&B
CKT.5 CKT.8 CKT.9
BED RM 1 BED RM 2

HALLWAY
PROPERTY LINE EXISTING FENCE

DINING CKT.7
AREA
KITCHEN DN
AREA
CKT.6

FIREWALL

FIREWALL
HALLWAY

LIVING

HALLWAY
AREA

PARKING TERRACE
AREA BED RM 1
UP
FIREWALL

FIREWALL
CKT.10

ROOFLINE
elev.0.00m

GROUND FLOOR LIGHTING LAYOUT PLAN SECOND FLOOR LIGHTING LAYOUT PLAN
SCALE 1:100MTS SCALE 1:100MTS

SIGNED BY: REG NO.: SEAL PROJECT TITLE: APPROVED BY: SHEET CONTENTS SHEET NO.
PTR NO.:
PLACE ISSUED:
PROPOSED 2-STOREY GROUND FLOOR POWER OUTLET LAYOUT PLAN E-3
DATE:
RESIDENTIAL SECOND FLOOR POWER OUTLET LAYOUT PLAN
3
ELECTRICAL ENGINEER OWNER
TIN NO.: LOCATION: PHASE 2, BLK 2, LOT 12 MARIANVILLE, TIPANOY ILIGAN CITY ELECTRICAL

You might also like