HOLD : FOR FINAL SIZING DESIGN CODE: ASME CODE, SECTION VIII DIV.1 2019 EDITION / AS 1210
N7 3"/TBD 150# RFWN 40S GAS OUTLET TOP DESIGN CONDITIONS FOR EXTERNAL PRESSURE: FULL VACUUM
N8 2" 150# RFWN 40S FOAM SENSOR TOP
N9 2" 150# RFWN 40S LEVEL SWITCH TOP NOZZLE N7 STEAM IN PLACE STEAM OUT CONDITIONS: 1 BAR (G) AT 120°C (NOTE 9)
N10 2" 150# RFWN 40S SPARE TOP N5 MDMT (MINIMUM DESIGN METAL TEMPERATURE): -30°C -10°C @ 5.0 BAR (G)
N11 2" 150# RFWN 40S SPARE BOTTOM N6
N12 2" 150# RFWN 40S PW INLET SIDE N8 TEST PRESSURE: PER CODE
N13 TBD 150# RFWN 40S RELIEF OUTLET TOP N7 TEST TEMPERATURE: PER CODE
N14 2" 150# RFWN 40S VENT GAS INLET TOP N9 JOINT EFFICIENCY: PER CODE
SIP STEAM INLET N10 HEADS: 2:1 ELLIPTICAL
N15 TBD 150# RFWN 40S (FUTURE/BLIND) TOP
N13 MINIMUM CORROSION ALLOWANCE FOR SHELL AND 1.5 MM
N7 HEADS:
P1 SG10 3" 150# RFWN 40S PRESSURE TRANSMITTER TOP N14
ZONE 2, GAS GROUP IIB+H2, TEMP CLASS T3 / AS 2380
SG1 THRU SG4 2"x18" - - - SIGHT GLASS SIDE ARCHON OBROUND SIGHTGLASS 2"x18" HAZARD LEVEL / ELECTRICAL ZONE: CLASS 1 DIVISON 2 GROUP B TEMP CLASS T3
OR EQUAL. NOTE 12 N9 N15 INSPECTION PROCEDURE: PER CODE
X1A 3" 150# RFWN 40S LEVEL DPT TOP LEG TOP P1
X1B 3" 150# RFWN 40S LEVEL DPT BOTTOM LEG BOTTOM EXTERNAL WELD FINISH: AS LAID, CLEANED
X1A INSULATION: NONE PROVIDE CLIPS AND RINGS FOR FIELD INSULATION BY OTHERS
HOLD : FOR FINAL SIZING
90° INSULATION TYPE / THICKNESS: NONE BY OTHERS
n4 internal piece will N4 TESTING PROCEDURE: HYDROTEST PER CODE
200 200 X1A 200 need to change N1 STRUCTURAL DESIGN CODE VESSEL: ASCE 7-10 AS 4100
100 250 400 400 200 200 200 400 250 SG1 0°
N7 T-BOLT STYLE HINGED ENCLOSURE SG2
VESSEL WEIGHT: NOTE 8
GENERAL NOTES:
200
N5 N14 N13 N6 NOTE 8 SG3
N1 SG4 1. ALL MATERIALS AND APPURTENANCES SHOWN ON THIS DRAWING, OR IN THE REFERENCED
N7
470
N10 N15 N8 N9 P1 135° ATTACHMENTS, SPECIFICATIONS, AND STANDARDS SHALL BE PROVIDED BY THE VESSEL FABRICATOR
UNLESS OTHERWISE NOTED. INTERNAL SPRAY HEADER AND DISTRIBUTOR / VANES BY OTHERS
SEPARATOR SHOWER 2. VESSEL THICKNESS AND MEMBER SIZES SHALL BE DETERMINED BY VENDOR. PHYSICAL DIMENSIONS
SEE SHT. 3 sight glasses different
SHOWN MUST BE MAINTAINED.
3. FLANGE BOLT HOLES SHALL STRADDLE CENTERLINES PARALLEL TO VESSEL CENTERLINES UNLESS NOTED
N9
1000
from what was built OTHERWISE.
N4 N12 4. ALL FLANGES SHALL BE PER ASME B16.5 OR B16.47 SERIES B WITH A 125-250 AARH GASKET CONTACT
180° FINISH UNLESS NOTED OTHERWISE.
90
1220 O.D.
N12 GLASSES 6. FABRICATOR SHALL PROVIDE LIFTING AND GROUNDING. LUGS
level switch was set
too low (and didn't
REQUIRED. SEE 7. OPERATING TEMPERATURES CAN RANGE FROM WATER INITIAL FILL TEMPERATURES (15 TO 80°C) TO
REF SKETCH FOR CLEAN-IN-PLACE (CIP) TEMPERATURE (80°C).
work) PLACEMENT
8. BY FABRICATOR.
add as branch on n7? 9. VESSEL TO BE RATED FOR STEAM OUT CONDITION.
10. INTERNAL NOZZLE PROJECTION FLUSH TO SHELL UNLESS OTHERWISE NOTED.
2:1 200 1700 100 200 SEPARATOR N2
11. MOUNTING OF VESSEL INTERNALS BY VENDOR.
12. FINAL LOCATION OF NOZZLES TO BE ASSIGNED BY DETAILED DESIGN.
ELLIPTICAL FRONT VIEW N3
HEAD NOT TO SCALE N11 12. VERIFY SIGHT GLASS NOZZLE SURFACE IS FLAT WIHTIN MANUFACTURER TOLERANCES
AFTER WELDING AND BEFORE SHIPMENT
can remove X1B
whichever of these 270°
X1B isn't being used
BUTT WELD FITTINGS ASTM A403 WP304L WPB DIMENSIONS PER ASME B16.9.
FITTINGS:
SCREWED FITTINGS ASTM A182 DIMENSIONS TO ASME B1.20.1.
SA193 GRADE B7M BOLTS OR STUDS OR EQUIVALENT. ASTM A194 GRADE 2HM NUTS.
BOLTING:
SA193 GRADE B7M BOLTS OR STUDS OR EQUIVALENT. ASTM A194 GRADE 2HM NUTS.
INTERNALS BOLTING:
GASKETING: GRAFOIL GRADE GHR OR EQUIVALENT. SPIRAL WOUND, STAINLESS STEEL WITH GRAPHITE FILL.
PROVIDE WITH 304SS INNER AND OUTER RETAINING RINGS.
HINGED HEAD CLOSURE 48" (1220) 304L ST STL CLOSURE WITH 2:1 ELLIPTICAL HEAD. PROVIDE WITH HINGE AND
T NUTS FOR CLOSURE. EPDM SQUARE PROFILE GASKET
WELDING
ALL WELD PROCEDURES TO BE QUALIFIED TO ASME IX.
WELDER QUALIFICATION REQUIRED.
UPDATE ISO WITH NOZZLE
CHANGES
ALL WELDS TO BE CONTINUOUS FULL PENETRATION OR FILLET WELDS ALL ROUND UNLESS INDICATED
OTHERWISE.
ALL WELDS TO BE DESCALED AND WIRE BRUSHED. WELD JOINTS SHALL BE SMOOTH AND FREE OF
SEPARATOR UNDERCUTTING, CREVICES, PITS, AND DEPRESSIONS.
ISOMETRIC
NOT TO SCALE UNIT: mm
N10 N5 N14 N13 N15 N8 N9 P1 N6 X1A N7
SG9 700
SUNCOR/ERA
# DATE REV BY APP
SG10
0 12 7 100 200 250 400 400 200 200 200 200 200 400 250 THESE DRAWINGS ARE LANZATECH CONFIDENTIAL INFORMATION AND INCLUDE 8045 Lamon Avenue, Suite 400
SG4
TRADE SECRETS, AND THE CONTENT OF THIS DOCUMENT IS AND SHALL REMAIN THE Skokie, Illinois 60077 USA
SG2
SG3
1
6 PROPERTY OF LANZATECH.
LanzaTech ANY FORMLLC OF REPRODUCTION, DISSEMINATION,
TITLE
NEXT GENERATION BIOREACTOR UNIT
Telephone: +1 847 324 2400
SG1 COPYING, DISCLOSURE, 8045
MODIFICATION, DISTRIBUTION AND/OR PUBLICATION OF LT LOGO, www.lanzatech.com
49
Lamon Avenue, Suite 400 USE NEW
SEPARATOR
B, TYPSHEET 1
2 SHTS
31
270
N4
90
N4 WOODSIDE ENERGY TECHNOLOGIES
N12 SG7 SG8
NP
5
GENERAL NOTES
1. ALL MATERIALS AND APPURTENANCES SHOWN ON THIS DRAWING, OR IN THE REFERENCED
ATTACHMENTS, SPECIFICATIONS, AND STANDARDS SHALL BE PROVIDED BY THE VESSEL FABRICATOR
UNLESS OTHERWISE NOTED.
2. VESSEL THICKNESS AND MEMBER SIZES SHALL BE DETERMINED BY VENDOR. PHYSICAL DIMENSIONS
SHOWN MUST BE MAINTAINED.
3. FLANGE BOLT HOLES SHALL STRADDLE CENTERLINES PARALLEL TO VESSEL CENTERLINES UNLESS NOTED
OTHERWISE.
4. ALL FLANGES SHALL BE PER ASME B16.5 OR B16.47 SERIES B WITH A 125-250 AARH GASKET CONTACT
FINISH UNLESS NOTED OTHERWISE.
5. VESSEL IS TO BE CLEARLY IDENTIFIED BY NAME PLATE.
INTENT OF DRAWING IS TO SHOW SHOWER HEADER SUPPORT ON THE TOP 6. FABRICATOR SHALL PROVIDE LIFTING AND GROUNDING.
CL. VESSEL 7. OPERATING TEMPERATURES CAN RANGE FROM WATER INITIAL FILL TEMPERATURES (15 TO 80°C) TO
OF THE VESSEL AND THE INTERNALS SUPPORT NEAR THE BOTTOM ONLY
CLEAN-IN-PLACE (CIP) TEMPERATURE (80°C).
8. BY FABRICATOR.
25mm W x 6mm THK. 9. VESSEL TO BE RATED FOR STEAM OUT CONDITION.
420 DELETED INTERNALS WILL BE
MOUNTING SUPPLIED BY OTHERS.
PLATE 10. INTERNAL NOZZLE PROJECTION FLUSH TO SHELL UNLESS OTHERWISE NOTED.
WELDED TO 11. MOUNTING OF VESSEL INTERNALS BY VENDOR.
12. FINAL LOCATION OF NOZZLES TO BE ASSIGNED BY DETAILED DESIGN.
100 DRAWINGS SHOWNSEPARATOR INTERNAL
50
ARE FROM PRIOR UNIT FABRICATION DRAWING AND ARE
15
NOT AVAILABLE ELECTRONICALLY 1. FABRICATED DISTRIBUTOR AND VANE PLATES ARE TO BE PROVIDED BY OTHERS
SEPARATOR INTERNALS 2. VESSEL FABRICATOR SCOPE IS LIMITED TO SUPPRT PLATES WELDED INSIDE VESSEL AND TRIAL FIT OF
INTERNALS PRIOR TO SHIPMENT
PLAN
150
3. VESSEL FABRICATOR TO ENSURE INTEROR OF VESSEL IS FREE OF INTERFERENCES WHIHC WOULD
PREFENT INTERNALS FROM SLIDING IN. THIS INCLUDES ANY WELD MATERIAL OR DISTORTION AS WELL AS
CL. VESSEL NOT TO SCALE GUIDES FOR HINGED VESSEL CLOSURE.
MOUNTING PLATE
10°ALONG WELDED TO
ENTIRE TROUGH VESSEL WALL
1
SPRAY HEADER
6 BY OTHERS
CURVE TO C 204
60° TO MATCH PLATES 25
GRADUALLY 149-1
APPROACH 3/16"
VESSEL WALL 12 7
90
65
285
NOT TO SCALE
25
110
429*
65
100
TYP TYP
8
CL. VESSEL SEPARATOR INTERNALS
ISOMETRIC
300
NOT TO SCALE
IMENSIONS TO 149-1
GRIND FLUSH
P OF FLAT BAR ON TOP
75 TYP
SURFACE 3/16" 406
SEPARATOR INTERNALS
3100
SIDE ELEVATION
NOT TO SCALE
NOTE 11 25mm HOLES SPACED 3.175 mm THK. TROUGH
H K. 100mm APART SECTION C-C
7 5T SCALE 1 : 10
3.1
90
65
6 CL. VESSEL
420
150
50
°
C
60
100
25mm W x 6mm THK.
MOUNTING PLATE 6mm THK. PLATE AT
100 mm LG x 3.175 mm THK. END THE END OF TROUGH
SEPARATOR INTERNALS WELDED TO PLATES PLATE
3340 6mm GAP TO MATCH
ELEVATION DETAIL 3240 mm LG x 3.175 mm 420
CURVATURE
NOT TO SCALE THK. FLOOR PLATE SEPARATOR INTERNALS MINIMIZE GAP BETWEEN PLATES AND VESSEL I.D.
PLAN SEPARATOR INTERNALS
NOT TO SCALE TROUGH/N4 DETAIL
NOTE 11 NOT TO SCALE
SUNCOR/ERA
# DATE REV BY APP
THESE DRAWINGS ARE LANZATECH CONFIDENTIAL INFORMATION AND INCLUDE TITLE
8045 Lamon Avenue, Suite 400
LanzaTech
TRADE SECRETS, AND THE LLC CONTENT OF THIS DOCUMENT IS AND SHALL REMAIN THE Skokie, Illinois 60077 USA
PROPERTY OFAvenue,
8045 Lamon LANZATECH.
Suite 400 ANY FORM OF REPRODUCTION, DISSEMINATION, Telephone: +1 847 324 2400 NEXT GENERATION BIOREACTOR UNIT
COPYING, DISCLOSURE,
Illinois 60077 USAMODIFICATION, DISTRIBUTION AND/OR PUBLICATION OF V-20001 SEPARATOR MECHANICAL DRAWING
www.lanzatech.com
SEPARATOR
DRG NO. SHEET 2REV.
Skokie,
INFORMATION
Telephone: +1IN 847THESE
324 2400 SPECIFICATIONS WHETHER IN WHOLE OR IN PART IS
STRICTLY www.lanzatech.com
PROHIBITED, EXCEPT WITH THE EXPRESS PRIOR WRITTEN CONSENT OF AN 1 12JUN20 IFBEP
PROJECT
AUTHORIZED REPRESENTATIVE OF LANZATECH. THIS CONFIDENTIALITY NOTICE SHALL
NB JC SHEET 221 OF
OF32 MECHANICAL DRAWING
BR2-12 A
NOT BE SEPARATED FROM THIS PAGE WOODSIDE ENERGY
OR ANY OF THE TECHNOLOGIES
PAGES ATTACHED HERETO. PTY LTDIFBEP GEE
0 12DEC19 NA EDMONTON, AB, CANADA PRJ: P1143 DWG: BR-2 REV: 1 DATE: 12JUN20
GENERAL NOTES
1. ALL MATERIALS AND APPURTENANCES SHOWN ON THIS DRAWING, OR IN THE REFERENCED
ATTACHMENTS, SPECIFICATIONS, AND STANDARDS SHALL BE PROVIDED BY THE VESSEL FABRICATOR
UNLESS OTHERWISE NOTED.
2. VESSEL THICKNESS AND MEMBER SIZES SHALL BE DETERMINED BY VENDOR. PHYSICAL DIMENSIONS
SHOWN MUST BE MAINTAINED.
3. FLANGE BOLT HOLES SHALL STRADDLE CENTERLINES PARALLEL TO VESSEL CENTERLINES UNLESS NOTED
OTHERWISE.
4. ALL FLANGES SHALL BE PER ASME B16.5 OR B16.47 SERIES B WITH A 125-250 AARH GASKET CONTACT
FINISH UNLESS NOTED OTHERWISE.
THROUGH NOZZLE N1 5. VESSEL IS TO BE CLEARLY IDENTIFIED BY NAME PLATE.
25mm W 6mm THK. 6. FABRICATOR SHALL PROVIDE LIFTING AND GROUNDING.
TO BORED THROUGH BLIND FLANGE MATED TO N1
PLATE TO SUPPORT SHOWER. 7. OPERATING TEMPERATURES CAN RANGE FROM WATER INITIAL FILL TEMPERATURES (15 TO 80°C) TO
NOTE 11 CLEAN-IN-PLACE (CIP) TEMPERATURE (80°C).
ALIGN SO AS NOT TO OBSTRUCT 8. BY FABRICATOR.
SHOWER PIPE DRILLED HOLES. N1 9. VESSEL TO BE RATED FOR STEAM OUT CONDITION.
10. INTERNAL NOZZLE PROJECTION FLUSH TO SHELL UNLESS OTHERWISE NOTED.
11. MOUNTING OF VESSEL INTERNALS BY VENDOR.
3190 12. FINAL LOCATION OF NOZZLES TO BE ASSIGNED BY DETAILED DESIGN.
520
U-BOLT CLAMP
260 260
N1
470
400
VOID
CL. VESSEL
125
TYPICAL
15°
120°
3 mm Ø HOLE
9 HOLES PER SET, EVENLY SPACED
RADIALLY DRILLED
3 mm Ø HOLES
9 HOLES PER SET
25 TOTAL SETS SEPARATOR SHOWER HOLES
LENGTH FROM FIRST SET TO LAST SET: 3.0 m CROSS SECTION
NOT TO SCALE
SEPARATOR SHOWER HOLES
PLAN SUNCOR/ERA
# DATE REV BY APP
THESE DRAWINGS ARE LANZATECH CONFIDENTIAL INFORMATION AND INCLUDE 8045 Lamon Avenue, Suite 400
TRADE SECRETS, AND THE CONTENT
LanzaTech OF THIS DOCUMENT LLC IS AND SHALL REMAIN THE
TITLE Skokie, Illinois 60077 USA
NOT TO SCALE PROPERTY OF LANZATECH. ANY FORM OF REPRODUCTION, DISSEMINATION,
8045 Lamon Avenue, Suite 400
Telephone: +1 847 324 2400 NEXT GENERATION BIOREACTOR UNIT
COPYING, DISCLOSURE, MODIFICATION, DISTRIBUTION AND/OR PUBLICATION OF
Skokie, Illinois 60077 USA www.lanzatech.com
V-20001 SEPARATORMECHANICAL DRAWING SEPARATOR SHEET 3
INFORMATION IN THESE SPECIFICATIONS
Telephone: +1 847 WHETHER
324 2400 IN WHOLE OR IN PART IS
WRITTEN CONSENT OF AN 1 12JUN20 IFBEP NB JC
MECHANICAL DRAWING
DRG NO. REV.
STRICTLY PROHIBITED, EXCEPT WITH THE EXPRESS PRIOR
www.lanzatech.com
AUTHORIZED REPRESENTATIVE OF LANZATECH. THIS CONFIDENTIALITY PROJECT NOTICE SHALL
SHEET 13 OF 3
3
NOT BE SEPARATED FROM THIS PAGE OR ANY OF THE PAGES WOODSIDE ENERGY
ATTACHED HERETO. 0 TECHNOLOGIES PTY NA
12DEC19 IFBEP GEE LTD EDMONTON, AB, CANADA PRJ: P1143 DWG: BR-2 REV: 1 DATE: BR2-1 12JUN20A