Professional Documents
Culture Documents
DESCRIPTION FEATURES
Designed for a wide range of standard + True RMS, revenue grade + Available compatibility with
metering projects, the Acuvim L is a cost- measurements: ANSI C12.20 multiple CT output options
effective, multifunction power meter that class 0.5 & IEC 62053-22 including 5A, 1A, 333mV,
class 0.5s and Rogowski coils
combines value and high-performance
with easy integration into panel or device + Multiple communication + Perform power quality
options including Modbus- analysis, measure individual
monitoring applications. With multiple
TCP/IP, BACnet-IP, harmonics up to the 63rd
communication options including Modbus-
PROFIBUS, Modbus-RTU, I/O order, and monitor THD
RTU, PROFIBUS, Modbus-TCP/IP, and BACnet-
communications, and more + Three form factors: Panel
IP through optional expansion modules and
+ NEMA 3 front panel mount meter with digital
revenue grade accuracy, the Acuvim L can be
protection for installation in display, DIN rail mount
configured as either a panel-mount device, harsh environments transducer, or in a pre-
as a DIN rail mount transducer, or installed wired, pre-configured panel
in a pre-configured, pre-wired AcuPanel for
extreme protection in even the toughest
application environments.
APPLICATIONS
ENERGY ACCURACY
Class 0.5s (According to IEC 62053-22)
Active
Class 0.5 (According to ANSI C12.20)
Reactive Class 2 (According to IEC 62053-23)
HARMONIC RESOLUTION
Metered Value 2nd~63rd harmonics
Measurement Standard IEC 61036 Class 1, ANSI C12.16 Class 10 Protocol: Modbus-TCP/IP, DNP3.0 over
IP V2, BACnet-IP, SNMP V3,
Environmental Standard IEC 60068-2 L-WEB (Optional Module)
HTTP/HTTPs post, FTP post, SMTP,
(Ethernet RJ45)
Safety Standard IEC 61010-1, UL 61010-1 NTP, HTTPs webserver;
4GB Datalogging memory
EMC Standard IEC 61000-4/2-3-4-5-6-8-11
Outlines Standard DIN 43700, ANSI C39.1 Operating Environment
-25°C to 70°C
Operating Temperature
-13°F to 158°F
-40°C to 85°C
Storage Temperature
-40°F to 176°F
Relative Humidity 5% to 95% Non-Condensing
Phase
Voltage/Current Phase Angles Voltage Phase Angle, Current Phase Angle
Angles
MAX with Time Stamp, Each phase of V & I; Total of P, Q, S, PF & F; Demand of I1, I2, I3, I4, P,
Statistics MIN with Time Stamp Q&S; Each phase THD of V & I; Unbalance factor of V & I
V, I, P, Q, S, PF, V_THD & I_THD Each Phase and Total or Average;
Alarm Over/Under Limit Alarm Unbalance Factor of V& I; Load Type; Demand of I1, I2, I3, P, Q&S;
Reverse phase sequence;
PQ Event Power Quality Event with Time
Voltage SAG and fail, Current overflow, Phase Sequence error
Logging Stamp
Ethernet Port 1
Datalogging 4GB
1.40" (35.5mm)
3.80" (96.0mm)
3.58" (91.0mm)
3.58" (91.0mm)
3.58" (91.0mm)
H P E V/A
Front View of the Display Meter and Side View of the Display Side View of the DIN rail Side View of the Remote
Remote Display Unit Meter Meter Display Unit
4.02" (102.0mm)
3.80" (96.0mm)
3.62" (92.0mm)
Cut-Out Cut-Out
3.62" (92.0mm)
3.80" (96.0mm)
3.54" (90.0mm)
3.54" (90.0mm)
2.12" (55.6mm)
2.19" (55.6mm)
0.77" (19.5mm)
0.87" (22.0mm)
0.20" (5.0mm)
3 Phase 4 Wire (Wiring: 3LN, 3CT; IN: Measured) 3 Phase 3 Wire (Wiring: 3LL, 3CT) 3 Phase 4 Wire (Wiring: 3LN,3CT; IN: Calculated)
LINE LINE LINE
A B C N A B C 1A FUSE A B C N
1A FUSE 1A FUSE
3 Phase 3 Wire (Wiring: 3LL, 3CT) I/O Module, DI, RO/DO Wiring Diagram
LINE
A B C 1A FUSE
Terminal Block
① I11 12 11 10 9
VN V3 V2 V1
② I12
③ I21
④ I22 Acuvim-L
⑤ I31
⑥ I32
⑦ I41
⑧ I42
LOAD
11 12
11 12
100~300Vdc
Power Supply
Power Supply
100~300Vdc
3W 3W
13
13
Acuvim-L Acuvim-L
DO1D O2 DOC
Communication
14
S
14 15 16
A
Energy Pulse
Pulse Output
RS485
Output
–
15
B
S
Vaux
16
+
S
3 Phase 4 Wire (3LN, 3CT) 3 Phase 3 Wire (3LL, 3CT) 3 Phase 3 Wire with PT and 3CT(2LL, 3CT)*
LINE LINE LINE
A B C N A B C A B C
1A FUSE 1A FUSE 1A FUSE
3 Phase 4 Wire with PT (3LN, 3CT) Single Phase 3 Wire (1LL, 2CT) Single Phase 2 Wire (1LN, 1CT)
A B C N LINE LINE
A N B A N
1A FUS E
1A FUSE 1A FUSE
ACCESSORIES
DIN Rail Adapter Protective Display Cover USB RS485 Converter
The AXM-DIN Rail Adapter is the easy The Protective Display Cover is This professional-grade, plug-and-
way to mount the Acuvim L Series designed for Acuvim L Series power play USB to Serial RS485 Converter is
multifunction power meter on either meters and other 96mm by 96mm compliant with both USB 1.1 and 2.0
horizontal or vertical DIN rail. The display panel meters. Crucial in standards and is designed to provide
adapter quickly secures to the meter harsh environments, it increases the a convenient, reliable USB connection
and is compatible with all I/O module IP environmental rating of a meter's to Acuvim L meters and other serial
options. display to IP66 or NEMA 4X. devices. It requires no external power
supply and provides both surge and
static electricity protection.
*Meters with RCT Current Input do not support I4, WIRING CHECK, POWER QUALITY, SEQUENCE, PHASE ANGLES, or POWER QUALITY EVENT LOGGING functions.
+ Communication
- Protocols + Accessories (Optional)
Module (Optional)**
Remote Display
WEB: Protocol: Modbus-TCP/IP, DNP 3.0 REM-DS1V3: Compatible with Acuvim-L Series “M”
Over IP V2, BACnet-IP, SNMP V3, HTTP/ (DIN Mount) models only
L
HTTPs post, FTP post, SMTP, NTP, HTTPs
DIN Rail Adapter
webserver; 4GB Datalogging
AXM-DIN: Compatible with Acuvim-L Series “D”
Ordering Example: L-WEB (Panel Mount) models only
96-IP66: Screen Protector for 96 x 96mm meters
+ I/O Module (Optional)** - Input/Output Type USB-RS485: USB-to-RS485 Converter
**Communications and I/O modules are not supported for Acuvim-BL meters.