You are on page 1of 7

OCT

OCT Retiview 500 Optical Coherence Tomography

Feature:

 Integrated Design: Everything is inside this compact body. No external computer is needed.
 Computer PC Inside: Data acquisition and processing are accomplished by the internal computer. The data can be
transported via USB or external hard drive. Peripheral devices, such as keyboard or printer, can be connected to the
computer ports.
 Easy Installation: No complex connection or setup. Compact body can fit in even small space.

CHONGQING VISION STAR OPTICAL CO., LTD www.hyvisionstar.com


OCT

CHONGQING VISION STAR OPTICAL CO., LTD www.hyvisionstar.com


OCT

CHONGQING VISION STAR OPTICAL CO., LTD www.hyvisionstar.com


OCT

Technical Data
Methodology Spectral domain OCT
Axial resolution ≤ 6 µm (in tissue)
Transverse resolution ≤ 20 µm (in tissue)
Scan depth ≥ 2.5 mm (in air)
Scan range ≥ 6 mm
Scan speed ≥ 24,000 A-scans/sec, up to 36,000 A-scans/sec
Scan modes 30, Raster, Circle
Fundus image OCT en face
Focus adjustment -150 to +150
Pupil diameter ≥ 3 mm
OCT light source 840 nm SLD
Optical power 750 µW (at cornea)
Operation 13.3’’ touch screen, optional external mouse or keyboard
Power supply 100-240 V, 50/60 Hz
Dimensions 497 mm × 395 mm × 490 mm (L × W × H)
Weight LED dot matrix
External fixation 34 kg (75 lbs)

CHONGQING VISION STAR OPTICAL CO., LTD www.hyvisionstar.com


OCT
OSE-2800 OCT Technical Data
OCT Imaging
Methodology Spectral domain OCT
Optical source 840nm (Light Center Wavelength)
Feature: Axial resolution (optical) 5 microns (optical), 3.6 microns (digital)
Transverse resolution 15 microns (optical), 3 microns (digital)
 For comprehensive glaucoma analysis,OSE-2800 offers two scan patterns, glaucoma cube scan in macular area a A-scan depth 3mm
nd glaucoma cube scan in discarea. Evenly distributed sampling point with 200 x 200 A-scans provides reliable in Diopter range -20 to +20 diopters
formation for early glaucoma detection and management. Scan patterns Macular: HD line scan (6 or 12 mm), 3D scan (6 mm x 6 mm), 6-line radial scan, Multi (X-Y:
 High definition OCT imaging of the cornea enables localization of the Bowman's layer, the interface between 5 x 5)
corneal stroma and epithelium Disc: 3D scan (6 mm x 6 mm)
 High definition hidden pathological OCT imaging reveals changes Anterior: HD line scan (6 or 16mm), 6-line radial scan
 Have a glimpse of the retina via HD imaging and quick data analysis Fundus Imaging
 Multiple HD cross-sectional images acquisition Methodology Line scanning laser ophthalmoscopy(LSLO)
 A point-by point assessment of retinal thickness with a 500 x 100 dense cube Minimum pupil diameter 3.0mm
Field of view 40⁰* 30⁰
Soft analysis
Macula
Retina thickness analysis; 3D view; En-face analysis; Progression analysis; EDI function
Glaucoma RNFL analysis; Ganglion cell analysis; Cup-disk analysis, Progression analysis; OU
comparative analysis
Anterior Segment Manual measurement; Corneal thickness analysis; Epithelial thickness analysis
Others DICOM conformance; Remote viewer software available

CHONGQING VISION STAR OPTICAL CO., LTD www.hyvisionstar.com


OCT
ANTERIOR SEGMENT
OSE-3000 Plus OCT  Anterior HD line:High-definition OCT imaging of the cornea enables localization of the Bowman’s layer, the
interface between corneal stroma and and epithelium, Anterior Chamber Angle,Manual measurement is
available.
 Anterior Six-line Radial:The anterior segment scanning through 6 radial lines of equal length can be used to
Feature: measure the central corneal thickness, Software Analysis, Corneal pachymetry, Manual measurement.

PERMIUM FUNCTIONS
 En-face Analysis:En-face OCT provides ability to precisely localize lesions within specific subretinal layers.
Choroid View
IS/OS-Ellipsoid View
Mid-Retina View
VRI View
3D En-face View
 Network System: Remote Analysis System: we provides a remote viewer software for displaying, enhancing,
analyzing and saving digital images obtained with OSE-3000/3000plus.
Remote Diagnosis System: Customer scan are reviewed remotely by specialists at Big Picture Eye Health for
over 45 eye pathologies.
The software immediately generates a customer report, including educational content and specialist referral if
needed.
This optional module,which is developed and operated by Big picture Eye Health, can be connected to OSE- 3000
seamlessly.

MACULA

 LSO: Equipped with LSO(Line Scanning Ophthalmoscopy)OSE- 3000 provides simultaneously high quality fundus
imaging,which is easy for physicians to localize the lesion.
 MACULA: Macula HD line: High definition OCT imaging reveals small lesions,OCT scan length can be switched
between 6mm and 12mm.
 Macula Six-line Radial: Having a glimpse of the retina with HD imaging and quick data analysis.
Software Analysis: Retinal thickness analysis, Ganglion cell analysis, High definition OCT imaging with 5 images
averaging.
 Macula Cube: A point-by-point assessment of retinal thickness with a 500x100 dense cube.
Software Analysis: Retinal thickness analysis, Progression analysis, 3D view, En-face analysis.

GLAUCOMA
 For comprehensive glaucomaanalysis. OSE 3000/3000 Plus offers two scan modes:glaucoma cube scan in macular
area and glaucoma cube scan in disc area. Evenly distributed sampling rate with 200x200 A-scans provides reliable
information for early glaucoma detection and management.
 Glaucoma(Macular): Software Analysis:Ganglion cell analysis, Progression analysis.
 Glaucoma(Disc): Software Analysis:RNFL analysis, Cup-disk analysis,Calculation circle and circle scan
tomogram,Progressionanalysis, OU comparative analysis.
 Informative Report: OU comparative analysis, Progression analysis report.

CHONGQING VISION STAR OPTICAL CO., LTD www.hyvisionstar.com


OCT
Technical Data
OSE-4000 OCT OCT Imaging
Methodology Spectral domain OCT
Optical source Super luminescent diode (SLD), 840 nm
Scan speed 80,000 A-scans/s
Axial resolution (optical) 5 microns (optical), 3.6 microns (digital)
Feature: Transverse resolution 15 microns (optical), 3 microns (digital)
A-scan depth 3mm
 45 wide range live SLO imaging. Diopter range -20 to+ 20 diopters
 Ultra fine quality retinal imaging using averaging technique(up to 50 images). Scan patterns Macular: HD line scan (6 or 12 mm), 3D scan (6 mm x 6 mm), 6-line radial scan,
 SLO based real-time retinal tracking effective lyreduces artifacts caused by eye movement. Multi (X-Y: 5 x 5)
 For comprehensive glaucoma analysis, OSE 4000 offers two scan patterns, glaucoma cube scan in macular area Disc: 3D scan (6 mm x 6 mm)
and glaucoma cube scanin discarea Evenly distributed sampling point with 200 * 200 A-scans provides reliabe inf Anterior: HD line scan (6 or 16mm), 6-line radial scan
ormation for early glaucoma detection and management. Fundus Imaging
 Optical Coherence Tomography Angiography (OCTA) is a new non-invasive imaging technique that allows the det Methodology Line scanning laser ophthalmoscopy (LSLO)
ailed study of low within the vascular structure of the eye without the need of dye injections. Minimum pupil diameter 3.0mm
 HD OCT imaging system at 80000 A-scans/s. Field of view 45 degrees
VASCAN TM
OCTA Module
VASCAN advance VASCAN essential
Scanning volume/area 3mm x 3mm 256 x 256 A-scans 3mm x 3mm 256 x 256 A-scans
6mm x 6mm 360 x 360 A-scans 12mm x 8mm 540 x 360
8mm x 8mm 360 x 360 A-scans A-scans
12mm x 8 mm 540 x 360 A-scans

Algorithm C-OMAG C-OMAG


Segmentation options Encoded, Vitreousretina Intrerface(VRI), Superfcial retina, Deepfcial retinal,
Avascular,
Choriocapillaris, Choriod, Custom
Quantitative analysis Yes Not available
Weight 30.5 kg
Dimension 532 mm (L) x 360 mm (W) x 540 mm (H)
Source voltage AC 100 - 240 V, 50 Hz - 60 Hz
Power input 90VA

CHONGQING VISION STAR OPTICAL CO., LTD www.hyvisionstar.com