You are on page 1of 3

Maintenance DEUTZ MWM

TBD 645

5 5.1.4.3 Maintenance plan supplement for operation with distillate fuel

after ... operating hours (oh) Description


300

1.000

3.000

6.000

8.000

12.000

18.000

24.000

36.000
Engine diagnostics B 0-2-5
Valve rotating device B 1-3-1
Valve clearance B 1-1-1
Lube oil sampling B 8-1-1
Air filter B 6-3-1
Lube oil in turbocharger B 6-6-2
Monitoring B 11-1-22 ff
Engine mounting B 3-7-1
Lube oil, governor/actuator B 5-3-1
Valve seat lubrication B 8-14-1
Injection nozzle B 7-7-2
Regulating shaft B 5-4-1
Backwash filter, engine end B 8-10-3
Exhaust valves W 1-5-3
Turbocharger bearing s. manufac.
Tors. vibr. abs., silicone oil sample B 12-1-1
Axial clearance of crankshaft W 2-1-4
Gear train (Drive End) B 4-4-4
Gear train (Free End) B 4-4-2
Lower valve mechanism W 4-2-1
Camshaft bearing W 4-1-1
Inlet valves W 1-5-2
Piston top W 2-9-6
Piston pin clearance W 2-12-3
Piston rings, grooves W 2-10-3
Cylinder liner W 3-3-1
Conn.-rod bearing W 2-9-3
Vibration absorber, camshaft W 4-9-1
Injection pump element W 7-4-2

Chapter 5 - Page 6 0299 4628-0108 1197


DEUTZ MWM Maintenance
TBD 645

5
after... operating hours (oh) Description
300

1.000

3.000

6.000

8.000

12.000

18.000

24.000

36.000
Main bearing W 2-7-2

Depending on the particular application and the engine loading involved, further work may be
necessary; compare in this context Chapter 5.1.5 and the job card listing (Operating Instructions
Chapter 9, Workshop Manual Chapter 2).

1197 0299 4628-0108 Chapter 5 - Page 7


Maintenance DEUTZ MWM
TBD 645

5 5.1.4.4 Maintenance and servicing as per instructions from component manufacturers


Check and clean drive compartment monitor

after ... operating hours or interval * Description


500 1,500 6,000
(monthly *) (quarterly *) (yearly *)
Underpressure in the
measuring chamber B 11-5-1
Sinter bronze filter in the
measuring add-on B 11-5-1
Fresh air bores in the mea-
suring add-on B 11-5-1
Infra-red filter glasses in the mea-
suring add-on B 11-5-1
Sinter bronze filter in the
pressure controller B 11-5-1

* if the operating hours specified are not achieved in the corresponding interval.

Chapter 5 - Page 8 0299 4628-0108 1197

You might also like