You are on page 1of 324

Nikolla Vesho

A methodology on the treatment of the issue of Cultural heritage restoration in


A methodology on the treatment
of the issue of Cultural heritage
restoration in Tirana,
period 1920-’40
BIM modeling, Seismic simulation and
Theoretical interpretatios

Tirana, period 1920-’40


Candidate: Nikolla Vesho

DA Supervisor: Prof. Riccardo Dalla Negra


DA Co-Supervisor: Prof. Marco Zuppiroli

External Supervisor: Prof. Donato Abruzzese

Cycle XXXIV

International Doctorate in Architecture and Urban Planning (IDAUP)


IDAUP XXXIV Cycle

International Consortium Agreement between University of Ferrara


Department of Architecture (DA) and Università Iuav di Venezia (IUAV)
and with Associate members 2014 (teaching agreement)
University of Malta / Faculty for the Built Environment;
Slovak University of Technology (STU) / Institute of Management and
University of Pécs / Pollack Mihály Faculty of Engineering and
Information Technology.
INTERNATIONAL DOCTORATE
IN ARCHITECTURE AND URBAN PLANNING

Cycle XXXIV

IDAUP Coordinator Prof. Roberto Di Giulio

A methodology on the treatment of the issue of Cultural Heritage Restoration in


Tirana, period 1920-40'
BIM Modeling, Seismic simulations and Theoretical interpretations

Curriculum: Architecture / IDAUP, Topic: Cultural Heritage Restoration, Seismic analysis and
Retrofitting, BIM Tools (Area – SSD: ICAR19)

Candidate Supervisor DA
Nikolla VESHO Prof. Riccardo DALLA NEGRA

(UNIFE Matr. N. 148581) Co-Supervisor DA


(IUAV. Matr. IUAV581N080013) Prof. Marco ZUPPIROLI

(Years 2018/2022)
Questa pagina è stata lasciata intenzionalmente vuota
Dichiarazione di conformità — Dottorati di ricerca https://www.unife.it/studenti/dottorato/it/esame/conformita

Sezioni

Dottorati di ricerca

Il tuo indirizzo e-mail


vshnll@unife.it

Oggetto:
Dichiarazione di conformità della tesi di Dottorato

Io sottoscritto Dott. (Cognome e Nome)


VESHO NIKOLLA

Nato a:
BERAT

Provincia:
ALBANIA

Il giorno:
02-12-1987

Avendo frequentato il Dottorato di Ricerca in:


International Doctorate in Architecture and Urban Planning

Ciclo di Dottorato
34

Titolo della tesi:


A methodology on the treatment of the issue of Cultural Heritage Restoration in Tirana, period
1920-40’. BIM modeling, seismic simulations and theoretical interpretations

Titolo della tesi (traduzione):

Tutore: Prof. (Cognome e Nome)


DALLA NEGRA RICCARDO

Settore Scientifico Disciplinare (S.S.D.)


ICAR 19

Parole chiave della tesi (max 10):


Cultural heritage, restoration, seismic analysis, retrofitting, nonlinear analysis, pushover

Consapevole, dichiara
CONSAPEVOLE: (1) del fatto che in caso di dichiarazioni mendaci, oltre alle sanzioni previste dal
codice penale e dalle Leggi speciali per l’ipotesi di falsità in atti ed uso di atti falsi, decade fin dall’inizio
e senza necessità di alcuna formalità dai benefici conseguenti al provvedimento emanato sulla base di
tali dichiarazioni; (2) dell’obbligo per l’Università di provvedere al deposito di legge delle tesi di
dottorato al fine di assicurarne la conservazione e la consultabilità da parte di terzi; (3) della procedura
adottata dall’Università di Ferrara ove si richiede che la tesi sia consegnata dal dottorando in 1
originale cartaceo e 1 in formato PDF/A caricata sulla procedura informatica Esse3 secondo le
istruzioni pubblicate sul sito: http://www.unife.it/studenti/dottorato alla voce ESAME FINALE –
disposizioni e modulistica; (4) del fatto che l’Università, sulla base dei dati forniti, archivierà e renderà
consultabile in rete il testo completo della tesi di dottorato di cui alla presente dichiarazione attraverso
la pubblicazione ad accesso aperto nell'Archivio Istituzionale dei Prodotti della Ricerca IRIS-UNIFE
(www.iris.unife.it) oltre che attraverso i Cataloghi delle Biblioteche Nazionali Centrali di Roma e
Firenze; DICHIARO SOTTO LA MIA RESPONSABILITA': (1) che la copia della tesi depositata presso

1 di 2 14/06/2022, 15:34
Dichiarazione di conformità — Dottorati di ricerca https://www.unife.it/studenti/dottorato/it/esame/conformita

l’Università di Ferrara in formato cartaceo è del tutto identica a quella caricata in formato PDF/A sulla
procedura informatica Esse3, a quelle da inviare ai Commissari di esame finale e alla copia che
produrrò in seduta d’esame finale. Di conseguenza va esclusa qualsiasi responsabilità dell’Ateneo
stesso per quanto riguarda eventuali errori, imprecisioni o omissioni nei contenuti della tesi; (2) di
prendere atto che la tesi in formato cartaceo è l’unica alla quale farà riferimento l’Università per
rilasciare, a mia richiesta, la dichiarazione di conformità di eventuali copie; (3) che il contenuto e
l’organizzazione della tesi è opera originale da me realizzata e non compromette in alcun modo i diritti
di terzi, ivi compresi quelli relativi alla sicurezza dei dati personali; che pertanto l’Università è in ogni
caso esente da responsabilità di qualsivoglia natura civile, amministrativa o penale e sarà da me
tenuta indenne da qualsiasi richiesta o rivendicazione da parte di terzi; (4) che la tesi di dottorato non è
il risultato di attività rientranti nella normativa sulla proprietà industriale, non è stata prodotta nell’ambito
di progetti finanziati da soggetti pubblici o privati con vincoli alla divulgazione dei risultati, non è oggetto
di eventuali registrazioni di tipo brevettale o di tutela. PER ACCETTAZIONE DI QUANTO SOPRA
RIPORTATO

Firma del dottorando


Ferrara, li ___14-06-2022__________ (data) Firma del Dottorando Nikolla Vesho

Firma del Tutore


Visto: Il Tutore Prof. Riccardo Dalla Negra Si approva Firma del Tutore

2 di 2 14/06/2022, 15:34
Title: A methodology on the treatment of the issue of Cultural Heritage Restoration in Tirana,
period 1920-40'
BIM Modeling, Seismic simulations and Theoretical interpretations

PhD Candidate: Nikolla VESHO


Department of Architecture UNIFE, Ferrara

DA Supervisor: Prof. Riccardo DALLA NEGRA


DA Co-Supervisor: Prof. Marco ZUPPIROLI
International Doctorate In Architecture And Urban Planning – IDAUP Cycle: XXXIV
Ferrara University – DA

Curriculum: Architecture
Topic: Cultural Heritage Restoration, Seismic analysis and Retrofitting, BIM Tools
(Area – SSD: ICAR19)

Years: 2018-2022
Questa pagina è stata lasciata intenzionalmente vuota
ABSTRACT IN ENGLISH

The history has left its mark on the Albanian culture and society, from the Roman Empire, Greek
colonies, Turkish Empire, to the Balkan and World Wars. Indescribable are the traces and
influence of Italian architects and designers between 1920 and 1940. The architecture of the
center of Tirana, reflected mainly along the main boulevard that divides the city into two parts,
is an undeniable proof of the symbiotic process that has always characterized the relationship
between Italian and Albanian culture in all dimensions.

By researching and analyzing the materials found in the technical archive of Tirana, also, the
Italian Luce Institute, specifically in the archives of L. Luiggi, G. Fiorini etc., it helps to better
understand the Italian vision for Tirana. Today, these sketches and drawings serve as a point of
reference for architects, engineers and restorers, as long as buildings need reconstruction or
intervention.

After the Second World War, these buildings were perceived as signs of a foreign invasion, but
over the last 30 years, superstitious ideologies have been replaced by a more peaceful evaluation
process. Built during the 20-40s for other purposes, after liberation they took other functions,
from universities, study centers, headquarters and ministry facilities, thus becoming an
inseparable part of the day-to-day and historic part of the city, intertwined and in cooperation
with each other. Now this historical-architectural heritage, that is shared among people, has
helped to change the initial perception.

This cultural heritage buildings of Tirana’s case provide structures and monuments of great
value, since they are proof of historic forms of life and the history of modern societies, and show
the existence of a tangible cultural identity. The architectural heritage adds character to its
surroundings, is an integral part of the city, and is also a valuable tourism resource. Nowadays,
architectural and cultural legacy are regarded as a perishable and valuable resource that must be
protected and passed on to future generations. However, protective programs are not always as
effective as they may be, owing to a lack of interest on the part of residents, professionals and
an unfavorable socioeconomic climate.

Performance of cultural heritage “buildings after earthquakes is the concern of people and many
professionals from different disciplines”. Although, everyone supports for protecting these
architectural masterpieces from seismic threats, the predicted loss to their aesthetic values (as a
result of additions and retrofitting processes) “hinders a required decisive consensus on whether
or not an action should be taken to save these national treasures. This could be due to a lack of
agreement on how to value the added value of seismic risk reduction on the building as a result
of structural strengthening” compared to the damage values related to any particular seismic
retrofit technique.

The age of these buildings is approaching 100 years, which makes us aware of the greatness of
the designers of that period. In this regard, this study aims to define the principles and secrets
of structural simplicity and to interpret theoretically their structural arguments. Plan and height
configurations, the most useful structural elements of the period and the ability to withstand a
large number of seismic events.
The strategic vision of the study is to develop a detailed methodology which can serve as a
manual for addressing the issue of restoration, as well as addressing the issue of structural
analysis of cultural heritage with the principles and international charters on restoration.
Theoretical analyzes and interpretations of the architectural solutions of the period will be
developed. The main goal is to treat the complicated modeling of buildings of the past, using
the building information modeling methodology as a tool that helps us improve the methods of
evaluation and parametric interaction. Regarding the proposals for intervention, it will be
attempted through this methodology, to create a controlled space monitored by experts, to
prevent damage to architectural assets during restoration.

The study will be carried out through theoretical approaches initially and literature research,
while later the methodology will take shape through the treatment of some cases of studies,
which have not been previously studied in this specific context. The Albanian context has shown
a lack of cooperation in a team of experts or governments have made this contribution even
more fragile. To achieve this goal, the right atmosphere of cooperation between experts must be
created, to consider their diverse perspectives. On the other hand, this research aims to raise
awareness of Tirana's cultural heritage past by fostering a debate on cultural heritage and its
future within a structured heritage framework. The study tends to stimulate the process of
digitalization by creation of 3d models including BIM, in such a way as to create accessible
database of materials, elements, combined architectural and structural models, database for
additions and retrofitting’s.

Also, in this study will be targeted to overwhelm the curiosity of researchers, students, aspirants
of doctoral studies or lovers of cultural heritage who want to know more about the architectural
and engineering part of the main buildings that marked the 20th century architecture of Albania.
Those buildings that surround us today define the spaces of our cities which still more tell us
how we were, how to judge the past and above of all how we can project the future.
ABSTRACT IN ITALIAN

La storia ha lasciato il suo marchio nella società e la cultura albanese da le colonie Greche al
Impero Romano dal Impero Ottomano alle guerre balcaniche fino alle guerre mondiali.
Descrivibili sono le tracce e l’influenza lasciata dagli architetti Italiani tra il 1920 al 1940.
L’Architettura del centro di Tirana, riflessa principalmente lungo il viale principale il quale
decide la città in due parti e prova indelebile del processo simbiotico che ha caratterizzato le
relazioni culturali tra Italia e Albania in tutte le dimensioni.
La ricerca e l’analisi dei materiali trovati al archivio del istituto Tecnico di Tirana e anche ne
archivio del Istituto Luce, specificamente negli archivi del L. Luigi e G. Fiorini sono stati d’aiuto
nel capire meglio la visione degli architetti Italiani per Tirana. Oggigiorno questi disegni
servono come punto di riferimento per architetti, ingegneri e restauratori per quanto riguarda al
bisogno di ricostruzione e intervento di manutenzione che questi edifici hanno. Dopo la seconda
Guerra Mondiale questi edifici venivano percepiti come memoria e segno del invasione
straniera, negli ultimi 30 anni queste ideologie e superstizioni furono rimpiazzate da un più
pacifico processo evolutivo. Costruitesi tra gli anni 20-40 per altri scopi dopo la liberazione
cambiarono destinazione d’uso trasformandosi in Università, centri di studi, sedi per Ministeri
diventando così parte inseparabile per la vita di ogni giorno e entrando a far parte nella storia
della citta, intersecandosi e comunicando tra di loro. Oggigiorno questo patrimonio Storico-
culturale condivisa ha aiutato a cambiare la percezione iniziale. Questo patrimonio culturale di
Tirana fornisce strutture di grande valore si come sono prova di storia e delle forme della vita e
della storia moderna della società. Il patrimonio architettonico da un distintivo aspetto al
contesto circostante a uno degli elementi essenziali della città e ancor più diventa una risorsa
turistica. Oggigiorno questo patrimonio culturale architettonica viene riconosciuto come fragile
e insostituibile, patrimonio che va preservata e trasmessa alle future generazioni. Comunque le
politiche di protezione non sempre sono efficienti come lo dovrebbe essere alle quali si aggiunge
un disinteresse cittadino e un clima socio-politica molto avversa.
La performanza degli edifici patrimonio culturale dopo i terremoti e una preoccupazione di tante
figure professionali di diverse discipline. Anche se tutti predicono la salvaguardia di questo
patrimonio culturale – architettonica dal rischio danneggiamento a causa dei terremoti, il
prevedibile danneggio di questi valori estetici di questi edifici (causa le addizioni e processi di
riqualificazione) viene ostacolato da una decisione consensuale sul bisogno di intervento o meno
nel salvaguardare questi tesori. Questo deriva dalla mancanza di una solida base di principi, nel
tenere conto dei fattori che incidono sulla riduzione del rischio sismico negli edifici, per il
consolidamento della struttura e nel contempo il danneggiamento dei valori attribuiti a specifici
tecniche di intervento. L’età di questi edifici si sta avvicinando ai 100° anni fatto che ci rende
consapevoli della grandezza degli architetti di quel periodo. Riguardo a questo studio tenta di
definire i principi e i segreti della semplicità strutturale e la reinterpretazione teorica degli
argomenti strutturali. Le configurazioni in piano e altezza, degli elementi strutturali più usati nel
periodo e l’abilita di sopportare a un ampio numero di eventi sismici.
La visione strategica di questo studio e di sviluppare una dettagliata metodologia la quale servirà
come manuale di riferimento nel indirizzare sia problemi di restauro anche i problemi del analisi
strutturale del patrimonio culturale con i principi delle carte internazionali sul restauro. Si
svilupperanno analisi teoriche e interpretazioni delle soluzioni architettoniche del periodo. Lo
scopo principale e di trattare il compilato modello degli edifici passato usando i BIM come
strumento di miglioramento dei metodi di valutazione e l’interazione parametrica. Al riguardo
delle proposte d’intervento tramite questa metodologia sarà tentato di creare uno spazio
controllato e monitorato da esperti, per prevenire danneggi agli assetti architettonici durante il
restauro. Questo studio verrà eseguito inizialmente tramite un approccio teorico e studio della
literatura mentre la metodologia prenderà forma tramite la considerazione dei casi studio i quali
non sono stati precedentemente nello specifico contesto. Il contesto albanese a dimostrato una
mancanza di cooperazione di gruppi di esperti o il governo ha fatto che questo contributo sia
ancora più fragile. Per raggiungere questo risultato bisogna creare l’atmosfera giusta di
cooperazione tra gli esperti considerando i punti di vista diversi. Da l’altra parte questa ricerca
mira ad aumentare la consapevolezza riguardo al patrimonio culturale di Tirana tramite la
creazione di un dibattito sul patrimonio culturale e il suo futuro al interno di una struttura di
lavoro. Questo studio tramite la creazione e la modellazione BIM inclusa, tenta di simulare il
processo di digitalizzazione in modo di creare un database di materiali, elementi, modelli
combinati strutturali accessibili per futuri interventi di restauro.
Inoltre questo studio si cerca di suscitare la curiosità di ricercatori, studenti, aspiranti dottorandi
di ricerca o semplicemente ammiratori del patrimonio culturale i quali vorranno sapere di più
degli aspetti architettonici e ingegneristici degli edifici che hanno marchiato l’architettura del
XX° secolo in Albania. Questi edifici che oggi definiscono lo spazio la quale oggi ci racconta
di come eravamo, come possiamo valutare il passato e come possiamo progettare il futuro.
ACKNOWLEDGEMENTS

First, I am extremely grateful to my professional supervisors, Prof. Riccardo Dalla Negra,


Prof. Marco Zuppiroli and Dr. Merita Guri “for their invaluable advice, continuous technical
support, and patience during my PhD study. Their immense knowledge and plentiful
experience have encouraged me in all the time of my academic research and daily life.”

Endless thanks and respect to Prof. Theo Zaffagnini and Prof. Roberto Di Giulio for their
patient assistance to my hasty actions.
Acknowledgments referring to these Universities, as follows: “University of Ferrara,
Department of Architecture, UNIROMA2 Department of Civil Engineering, Politechnic
University of Bari DICAR/POLIBA and Polis University”, that enabled this study. Also,
the unlimited support of Prof. Besnik Aliaj.

I would also like to thank Prof. Donato Abruzzese, Prof. Andrew Charleson, Prof.
Svetlana Brzev and Dr. Isak Idrizi for their technical support on my study, especially in
the field of structural and seismic engineering. I would like to thank all the members in the
IDAUP XXXIV cycle. It is their kind help and support that have made my study and PhD-life
a wonderful time.

Lastly, “I would be remiss in not mentioning my family, especially my parents. Their belief
in me has kept my spirits and motivation high during this process. I would also like to thank
my cat for all the entertainment and emotional support.”
Questa pagina è stata lasciata intenzionalmente vuota
Table of Contents

ACKNOWLEDGEMENTS ...................................................................................................... 5

List of figures ........................................................................................................................ 13


List of tables ............................................................................................................................. 24
Symbols and Abbreviations .................................................................................................... 25
Abstract .................................................................................................................................... 27
CHAPTER 1............................................................................................................................. 29
Introduction ............................................................................................................................... 29
1.1 Extended Introduction...................................................................................................... 30
1.2 Aims and Objectives of the thesis.................................................................................... 33
1.3 The research questions ..................................................................................................... 35
1.6 Expected results ............................................................................................................... 42
1.6.2 Stakeholders ............................................................................................................. 42
1.6.3 International interest in this research ....................................................................... 42
1.7 Reasons to make this study and select this topic ............................................................. 43
CHAPTER 2............................................................................................................................. 44
Research on Structural, Architectural and Urban typologies of the period 1920', Italian design
models........................................................................................................................................ 44
2.1 General characteristics of unreinforced masonry buildings designed in the 1920s ......... 45
2.2 Italian concept, building design and planning strategies for the Albanian cities............. 49
2.2.1 Tirana, the construction of a capital city. Birth and evolution of the Ottoman city .. 50
2.2.2 Identification and the performance of the cultural heritage in Tirana....................... 51
2.3 General characteristics of existing masonry and rc structures, period 1940 in general ... 52
CHAPTER 3............................................................................................................................. 56
Theory of Restoration and Architectural Interpretations........................................................... 56
3.1 Theoretical summaries, elaborations and analysis on the principles of International
Charters for Conservation and Restoration ............................................................................ 57
3.1.1 International conference of Athens, the charter of Athens 1931’ ............................. 57
3.1.2 Italian international charter for the conservation and restoration of monuments 1932'
............................................................................................................................................ 58
3.1.3 Analysis and notes on the context of the 1964 Venice Charter ................................ 59
3.2 The concept of restoration according to Cesare Brandi ................................................... 61

7
3.2.1 Restoration principles and Terminology defined ...................................................... 63
3.2.2 Genesis of Cultural Heritage ..................................................................................... 63
3.3.1 Restoration according to the historical instance ........................................................ 67
3.3.2 The restoration according to the aesthetic requirement ............................................ 67
3.3.3 The space of the work of art ...................................................................................... 67
3.3.4 Preventive restoration ................................................................................................ 67
3.3.5 Theoretical analysis on the basic principles of restoration of the work of art .............. 67
3.4 Analysis, reflection and browsing on the theories of Cesare Brandi ............................... 72
3.5. Interpretations and theoretical analysis on the architectural principles of interventions.
Consolidation of mortar from the architectural point of view ............................................... 74
3.5.1 Degradation and consolidation of old mortar............................................................ 74
3.5.2 Causes of degradation in nineteenth and twentieth century mortars (Oddy &
Linstrum, 2005) .................................................................................................................. 75
3.5.3 Consolidation of nineteenth and twentieth century mortars...................................... 75
CHAPTER 4............................................................................................................................. 77
Engineering theoretical framework ........................................................................................... 77
4.1 Literature Review. Observations on Design Codes in the past and now, related to the
Masonry Structures Design .................................................................................................... 78
4.1.1 European Standards, Eurocodes related to the study of masonry and mortar ........... 78
4.1.2 Observations on the current Albanian Code of Design and Implementation for
masonry structures according to KTP-1978 ....................................................................... 79
4.1.3 Masonry structures, a brief description ..................................................................... 81
4.2 Impacts affecting the performance of structural walls ..................................................... 82
4.3 Materials and components of masonry structures ............................................................ 82
4.3.1 Filling elements, masonry units .................................................................................... 83
4.4 Mechanical properties of structural unreinforced masonry elements .............................. 84
4.4.1 Compressive strength of the masonry materials ........................................................... 84
4.4.2 Tensile strength of unreinforced masonry .................................................................... 84
4.4.3 Modulus of elasticity and Poisson coefficient for masonry elements........................... 84
4.5 Mortar and binders ........................................................................................................... 85
4.5.1 Types of mortars ........................................................................................................... 85
4.5.2 Compressive strength of mortar ................................................................................ 86
4.5.3 Other mechanical resistances ........................................................................................ 87
4.4.4 Modulus of Elasticity, Slide Modulus and Poisson Coefficient ................................... 87
4.5 Concrete used for antiseismic elements in masonry ........................................................ 88
8
4.5.1 Reinforcement ........................................................................................................... 88
4.6 Use of FRP Materials in masonry structures ................................................................... 88
4.7 Compressive strength of retaining walls (brick and mortar together) ............................. 88
4.7.1 Shear-slide resistance of the masonry ........................................................................... 89
4.7.2 Shear resistance for horizontal sliding, Review and reflection according to Italian
literature and NTC-code ........................................................................................................ 90
4.8 Observations and interpretations on the experimental tests............................................. 91
4.8.1 The collapse mechanisms ............................................................................................. 92
4.8.2 Reviews and analyzes of masonry constituent materials .......................................... 93
4.9 Information for structural assessment: knowledge levels according to Eurocode ........... 93
4.10 Recommendations for interventions on monumental heritage with a specialized and
specific typology in seismic areas. Part of the state of art ..................................................... 94
4.10.1 Interpretations summarized from the recommendations issued in Italian case 1986
............................................................................................................................................ 94
CHAPTER 5............................................................................................................................. 99
Seismic, Technical Observations on Parameters, Estimates and Methodology ........................ 99
5.1.0 Seismic risk assessment .............................................................................................. 100
5.1.1. Seismic risk in Albania .......................................................................................... 100
5.1.2. Seismic action referring to current studies and methods according to Eurocode ...... 102
5.1.3. Seismic loads combination ..................................................................................... 104
5.2. Two significant Earthquakes that have influenced structures and architecture in
Albania, to be considered for the study ............................................................................... 105
5.2.1 Analysis and assessments on strong seismic events and the Earthquake of November
26, 2021 in Albania .......................................................................................................... 105
5.2.2 Details of the seismic event of November 26, 2019 in Albania.............................. 106
5.3.0 Theoretical interpretations on the impact of earthquakes and seismic risk on
masonry structures, regarding the practice of design codes in Albania ........................... 110
5.3.1 Seismic risks affecting the safety of masonry buildings ......................................... 111
5.3.2 Seismic events and movements of the basement .................................................... 112
5.3.3 Combination of loads .............................................................................................. 112
5.4. Calculation methods ..................................................................................................... 113
5.4.1 The equivalent frame Method ................................................................................. 113
5.4.2 Masonry calculation models and typologies ........................................................... 116
5.4.3 The definition of “Resistant mechanism” of a shear (or bracing) wall ................... 118
5.4.4 Technical behaviors of unreinforced masonry structures ....................................... 119

9
5.4.5 Theoretical Interpretations on Pushover Nonlinear static procedures .................... 122
5.4.6 Determining the performance point of the structure related to nonlinear procedure
.......................................................................................................................................... 122
CHAPTER 6........................................................................................................................... 124
Case Studies – Experimental Part............................................................................................ 124
6.1. CASE 1 - General overview of the Municipality of Tirana building, part of Cultural
Heritage. Architectural identification, survey process and structural evaluation .............. 125
6.1.1 Collection of data .................................................................................................... 127
6.1.2. Architectural survey process and monitoring on-site ........................................ 128
6.1.3 Structural evaluation, methodology and Analysis .................................................. 135
6.1.4 Use of F.E.M. interpretation of the crack Pattern and their distribution ................. 135
6.1.5. Structural evaluation and seismic performance of the building ........................ 136
6.1.5.1 Materials, mechanical properties after performing laboratory tests on materials 137
6.1.6 The concept of the foundations ............................................................................... 140
6.1.7 Seismic Parameters ................................................................................................. 141
6.1.8 Seismic analysis results and modal parameters....................................................... 142
6.1.9. Local stresses and strain distribution in main facades ....................................... 143
6.1.10. The second phase of BIM modeling through “3muri software”, static nonlinear
analysis and investigations into possible collapse scenarios ............................................ 150
6.1.10.1 Analysis of an effective consolidation strategy, making assessments, without
compromising architectural values and with relevant simulations .................................. 167
6.1.10 Summarized conclusions for case one .................................................................. 173
6.1.10.1 Discussions on the results obtained from the simulations in 3Muri .................. 177
6.2 CASE II - General overview of the “Casa del Fascio”, Polytechnic University of Tirana
............................................................................................................................................. 179
6.2.1 Architectural Survey and structural on-site investigation ....................................... 180
6.2.3.1 Theoretical interpretations, stratification and analysis methodology................... 187
6.2.3.2 Technical description of the second case study “Casa Del Fascio-Tirana” ......... 187
6.2.3.3 Theoretical interpretations of the perimetral masonry, as an essential element in
the structural performance of the building. ...................................................................... 187
6.2.4 The Calculation model .......................................................................................... 188
6.2.5 Characteristics and data of Materials, investigation on static calculations ....... 189
6.2.6 Seismic analysis and Results ............................................................................. 194
6.2.7 Non-linear analysis and the theoretical concept of the model ........................... 199
6.2.8. Results obtained after performing nonlinear analysis ............................................ 202

10
6.2.8.1 In-depth analysis in the framework of BIM modeling through “3muri software”,
analysis and investigations into possible masonry collapse scenarios ............................. 209
6.2.8.2 Efficient intervention strategy, aimed at increasing the seismic performance ..... 218
6.2.9 Case II, Conclusions and recommendations ........................................................... 223
6.2.9.1 Interpretations related to Nonlinear static analysis "Pushover" ........................... 224
6.2.9.2 Proposals for local interventions, in terms of seismic readjustment of the structure
.......................................................................................................................................... 225
6.2.8.1 Conclusions regarding the analysis and investigations applied in 3Muri software,
recommendations for possible effective interventions ..................................................... 228
6.3 CASE III - Analysis of “Ex. Opera Dopolavoro Albanese” University of Fine Arts today
............................................................................................................................................. 230
6.3.1 The process of surveying, photographing and digitizing the archival project ........ 232
6.3.2 Theoretical interpretations of the structural concept of the building ...................... 243
6.3.3 Concepts on the methodology of the calculation F.e.m.[] Model ............................ 245
6.3.3.1 Modeling of piers ................................................................................................. 246
6.3.3.2 Spandrels modelling ............................................................................................. 247
6.3.4 Tabular summary of mechanical data of materials related to the third case study . 248
6.3.4.1 Data on the dimensions of the basic elements, interpretations on structural
solutions ........................................................................................................................... 248
6.3.4.2 Summary of spectral data used in the seismic analysis ........................................ 249
6.3.5 Seismic Analysis and Results.................................................................................. 250
6.3.5.1 Local results and diagrams ................................................................................... 252
6.3.5.1 In-depth analysis in the framework of BIM modeling through “3muri software”,
analysis and investigations into possible masonry collapse scenarios ............................. 256
6.3.6 Conclusions and recommendations for the third case, regarding seismic simulations
.......................................................................................................................................... 263
6.3.6.1 Summaries and conclusions regarding the nonlinear simulations performed in
3Muri ................................................................................................................................ 263
CHAPTER 7........................................................................................................................... 265
Summaries and Conclusions.................................................................................................... 265
7.1 Summary of final Conclusions and Recommendations ................................................. 266
7.2 Comments and Recommendations on Modeling, findings from the interaction of data
files....................................................................................................................................... 271
Bibliography ........................................................................................................................... 276
8. APPENDIXES.................................................................................................................... 281

11
8.1 APPENDIX A. “The former building of National Theatre”. Numerical analysis and
investigations, before and after demolition - CASE IV ....................................................... 282
8.1.1 The historical and architectural context of the case ................................................ 282
8.1.2 Theoretical interpretations of the case and methodology used ................................... 286
8.1.3 Explanations and interpretations on the structural model used .................................. 287
8.1.4 Modal analysis “Structural evaluation and seismic performance of the National
Theater, Tirana” ................................................................................................................... 288
8.1.5 Seismic parameters ..................................................................................................... 290
8.1.6 Seismic analysis and results obtained ......................................................................... 290
8.1.7 Summarized conclusions and recommendations ........................................................ 292
8.2 APPENDIX B “Technical engineering and architectural diagrams” – CASE I ............ 294
8.3 APPENDIX C “Technical engineering and architectural diagrams” – CASE II........... 299
8.4 APPENDIX D “Technical engineering and architectural diagrams” – CASE III ......... 308

12
List of figures

Figure 1. Initial framework of the study, Research stages and Management (source: author) 39
Figure 2. Principal methodology and process applied for cultural heritage on this study, main
inputs of theoretical concepts used and literature, research strategy, application, long-term
strategy and expected outputs (source: author) ......................................................................... 41
Figure 3. General diagram on the research method proposed in one of the cases selected for
analysis of this study. (source: author) ...................................................................................... 41
Figure 4. Complete “collapse of a tiled floor after severe water” penetration (Oddy & Linstrum,
2005) .......................................................................................................................................... 75
Figure 5. Cracks in normal elements in tensile stress and Tensile stress in elements including
mortar deformation .................................................................................................................... 89
Figure 6. resistant shear - break by shear-sliding ..................................................................... 90
Figure 7. Pure shear test (faces remain parallel), shear and bending test, simple compression
test, diagonal compression test .................................................................................................. 91
Figure 8. First shape of the collapse mechanism, sliding of joints ........................................... 92
Figure 9. Second shape of the collapse mechanism, Cracking of blocks ................................. 92
Figure 10. Third shape of the collapse mechanism, Combined mechanism ............................ 92
Figure 11. Third shape of the collapse mechanism, Crushing in the vicinity of the load devices
................................................................................................................................................... 93
Figure 12. Map of tectonic faults on the left, tectonic map of Albania on the right (IGJEUM)
................................................................................................................................................. 100
Figure 13. (a) Map of the current design code for seismic zoning of Albania, year 1979, (b)
New seismic map, related to peak ground acceleration PGA recurrence period 95 years, return
period 95 years, probability of exceeding 10%, Summarized and re-worked by the Institute of
Geosciences (IGJEUM) ........................................................................................................... 101
Figure 14. Comparison of elastic response spectra based on the seismic requirements of KTP-
N.2-78, KTP-N.2-89 dhe EN 1998-1 ...................................................................................... 102
Figure 15. Recommended elastic response spectra according to Eurocode-8 ........................ 104
Figure 16. Summary diagram developed by the institute of seismology, after the seismic events
of 2019 (Source: IGJEUM) ..................................................................................................... 106
Figure 17. Quake M6.4 affected area and the lines distribution of shakes intensity (Charleson
& Vesho, 2020) ....................................................................................................................... 107
Figure 18. Two response spectra from Tirana re-worked and compared to the current design
code elastic spectrum (Charleson & Vesho, 2020).................................................................. 108
Figure 19. Data related to M.6.4 Durres earthquake spectra, 5% damped spectral acceleration –
period (Source: IGJEUM/ Graphically processed by author) ................................................. 108
Figure 20. Data related to M.6.4 Durres earthquake fourier amlitude based on frequency and
amplitude (Source: IGJEUM).................................................................................................. 109
Figure 21. Data related to M.6.4 Durres earthquake acceleration recorded (Source: IGJEUM)
................................................................................................................................................. 109

13
Figure 22. Data related to M.6.4 Durres earthquake Velocity and Displacement recorded
(IGJEUM) ................................................................................................................................ 110
Figure 23. Data related to M.6.4 Durres earthquake Velocity and Displacement recorded
(IGJEUM) ................................................................................................................................ 110
Figure 24. Equivalent frame method model and elements ..................................................... 114
Figure 25. Experimental model with openings (Dolce, 1989/ Graphically processed by author)
................................................................................................................................................. 115
Figure 26. The panel under the action of static actions N,T,M .............................................. 115
Figure 27. Type-a & b of computational models of micro-modeling and macro-modeling .. 117
Figure 28. Type-c & d of computational models of micro-modeling and macro-modeling .. 117
Figure 29. The model that represent the resistant mechanism of shear .................................. 118
Figure 30. The stages that the resistance model goes through until deformation, and how it is
conceived in static aspects ....................................................................................................... 119
Figure 31. Failure shapes regarding in plane loaded masonry panel, first panel in flexure and
second panel in rocking ........................................................................................................... 120
Figure 32. Failure shapes regarding in plane loaded panel, first in Sliding & second in diagonal
shear stress ............................................................................................................................... 120
Figure 33. (a) Failure mechanism of Storey shear located on Upper storey, (b) Failure
mechaninsm related to Storey shear, (c) the failure mechanisms of whole wall overturning, (d)
the failure mechanisms related to partial wall overturning. .................................................... 121
Figure 34. Gable wall overturning failure mechanisms and the Vertical instability failure
mechanisms of the wall. .......................................................................................................... 122
Figure 35. Municipality of Tirana original drawings of F. Di Fausto 29’ project-idea (Source:
AQTN) ..................................................................................................................................... 125
Figure 36. On the left, an old archive photo which shows the works on the construction of the
Di Fausto building near Skenderbej Square, on the right an identification scheme of cultural
heritage objects near the center. .............................................................................................. 126
Figure 37. An identification diagram of cultural heritage objects near the center combined by
photo collage for each monument ........................................................................................... 127
Figure 38. Basement floor according to F. Di Fausto idea, 1929 project-idea (Source: AQTN)
................................................................................................................................................. 128
Figure 39. Ground floor according to F. Di Fausto idea, 1929 project-idea (Source: AQTN)
................................................................................................................................................. 128
Figure 40. (a), (b) Section cut and the south façade behind, from the “F. De Fausto projcet idea
1929”, (c) Section cut from the implementing project 1941 (Source: AQTN) ....................... 129
Figure 41. Architectural survey of two typical windos on the main façade, digitalization process
................................................................................................................................................. 129
Figure 42. Architectural survey of the two main doors of the main façade, digitalization process
................................................................................................................................................. 129
Figure 43. Municipality of Tirana analytics and architectural diagrams (credits D. Gjuraj & A.
Kapaj) ...................................................................................................................................... 130

14
Figure 44. Summary and collage of photos from outside and inside the building, part of the
survey process (credits: D. Gjuraj & A. Kapaj) ...................................................................... 131
Figure 45. The process of architectural surveying, (a) main façade west side; (b) south side
façade; (c) north side façade; (d) behind façade view, positioned in addition ........................ 132
Figure 46. The process of architectural surveying, monitoring and analysis on facade
maintenance issues (credits D. Gjuraj & A. Kapaj) ................................................................ 133
Figure 47 Parts of architectural survey process, all plans, main section cut, raports between two
different typologies of structures in plan, foundation plan combined by architectural details
analysed ................................................................................................................................... 134
Figure 48. Municipality of Tirana, Updated ground floor plan after restoration (Dhimgjini,
Katundi, & Paci, March, 2001)................................................................................................ 135
Figure 49. Case study 1 updated model after interventions (Dhimgjini, Katundi, & Paci, March,
2001) ........................................................................................................................................ 136
Figure 50. The municipality building, worked on ETABs v16.2.0 (June 21, 2019) .............. 137
Figure 51. (a) Photo taken while sampling red brick on a perimeter wall panel, inside the
basement; (b) sample of red brick preparing for laboratory test, (c) Sample of red brick during
the laboratory test in printing, (d) Sample of red brick after completion of the test in
compression, at the point of destruction (Altea & geostudio, 2019) ....................................... 137
Figure 52. (a) Photo taken while sampling white brick on a perimeter wall, the eastern part from
behind; (b) sample of white brick taken on the north façade wall, (c) Sample of white brick
during the laboratory test in printing, (d) Sample of white brick after completion of the test in
compression, at the point of destruction (Altea & geostudio, 2019) ....................................... 138
Figure 53. (a) The result of the red brick digimax test for the compression test; (b) + (c) the
results of white brick samples (Altea & geostudio, 2019) ...................................................... 138
Figure 54. (a) sample of mortar during the compression test, (b) sample of mortar after
completion of the test, point of collapse, (c) test result in digimax (Altea & geostudio, 2019)
................................................................................................................................................. 138
Figure 55. A unified model for the seismic analysis of brick masonry structures (Xu, Gentilini,
Ju, Wu, & Zhao, 2018) ............................................................................................................ 140
Figure 56. Theoretical model referring Timoshenko and Euler (left), the case study physical
model (right) (Vesho, Guri, Marku 2019) ............................................................................... 140
Figure 57. Foundation structural plan of the Di Fausto implementing project 1941 (source:
Archive) ................................................................................................................................... 140
Figure 58. Elastic demand spectrum, referring Tirana ground parameters (ETABS, 2019) .. 141
Figure 59. The first 3 modes of vibrations according the modal analysis (CEN Eurocode 8,
Eurocode 8: Design of structures for earthquake resistance -Part 1: General rules, seismic
actions and rules for buildings, 2008) (ETABS, 2019) ........................................................... 142
Figure 60. Resultant Shell forces on main facade, f1-1 and f2-2 (ETABS, 2019) ................. 143
Figure 61. Resultant shell stresses S1-1 and S2-2 on the main facade (ETABS, 2019) ........ 143
Figure 62. Shear force distributed on 2 directions, V1-3 and V2-3 (ETABS, 2019) ............. 144
Figure 63. Resultant shell stresses in the area when the new frame system is linked with existing
wall (ETABS, 2019) ................................................................................................................ 144
15
Figure 64. Seismic Displacements according to Combination 1, Δx-x and Δy-y (ETABS,
v.2019) ..................................................................................................................................... 145
Figure 65. Maximum story displacements according to seismic actions in two directions E-x,
E-y (ETABS, v.2019) .............................................................................................................. 145
Figure 66. Comparison between Modal and combination 1 of Maximum story displacements
(ETABS, v.2019) ..................................................................................................................... 145
Figure 67. Story drifts comparison between seismic E-x and E-y direction (ETABS, v2019)
................................................................................................................................................. 146
Figure 68. Story drifts comparison between modal analysis and combination-1 (ETABS, v2019)
................................................................................................................................................. 146
Figure 69. Story shear force distribution against seismic actions Ex-x and Ey-y (ETABS,
v2019) ...................................................................................................................................... 147
Figure 70. Story shear force distribution against seismic actions Ex-x and Ey-y (ETABS,
v2019) ...................................................................................................................................... 147
Figure 71. Virtual relative energy/work related to the main façade, related to comb-1 (ETABS,
v.2019) ..................................................................................................................................... 148
Figure 72. Distribution of the resultiant seismic force F1-1 in 2 front facades, related to comb-
1 (ETABS, v.2019) .................................................................................................................. 148
Figure 73. Distribution of the resultiant seismic force F2-2 in the two front facades, related to
comb-1 (ETABS, v.2019)....................................................................................................... 148
Figure 74. Distribution of the stress σ-x in the two front facades, related to comb-1 (ETABS,
v.2019) ..................................................................................................................................... 149
Figure 75. Distribution of the stress σ-y in the two front facades, related to comb-1 (ETABS,
v.2019) ..................................................................................................................................... 149
Figure 76. Distribution of the Strain ε1-2 in the two front facades, related to comb-1 (ETABS,
v.2019) ..................................................................................................................................... 149
Figure 77. Axonometric model of the building, created in 3Muri v.13 software. Geometric
modeling, creation of volumetrics and data entry of materials ............................................... 150
Figure 78. Computational model generated in 3Muri showing three of the component elements,
piers spandrels and rigid nodes. The model presented in the axonometric version and the
calculation model of the main facade in the western position of the building ........................ 151
Figure 79. Image of the summary table of the number of analyzes performed in the framework
of pushover analysis in 3Muri-v.13 ......................................................................................... 152
Figure 80. Summary diagram of structure capacity curves according to 24 nonlinear analyzes
according to the combination of 2 seismic directions ............................................................. 152
Figure 81. +X and -X direction combined capacity diagrams, processed from 3Muri numerical
data .......................................................................................................................................... 153
Figure 82. +Y and -Y direction combined capacity diagrams, processed from 3Muri numerical
data .......................................................................................................................................... 153
Figure 83. Physico-mechanical parameters and characteristics of the recommended
reinforcement layer "Geosteel g1200", according to the database used in 3Muri software .... 168

16
Figure 84. Image of the component assembly of the material FRCM GeoSteel G1200,
(Kerakoll, 2021) ...................................................................................................................... 169
Figure 85. Casa del Fascio position and relations with other cultural heritage at the boulevard
(Credits: S. Agalliu)................................................................................................................. 179
Figure 86. Image processed with photogrammetry of the main facade of the building ......... 181
Figure 87. Image processed with photogrammeter of the facade from behind ...................... 181
Figure 88. Photogrammetrically processed images of the side facades ................................. 181
Figure 89. First aeral photo, showing the volumetric blocks, made by drone (credits: M. Begeja)
................................................................................................................................................. 182
Figure 90. Second aerial photo made by drone (credits M. Begeja) ...................................... 183
Figure 91. Third aerial photo made by drone (Credits M. Begeja) ........................................ 183
Figure 92. Archival project digitalization and comparisons with the actual survey, ground floor
(credits: H. Nika; M. Lleshi; M. Begeja)................................................................................. 184
Figure 93. Archival project digitalization and comparisons with the actual survey, ground floor
(credits: H. Nika; M. Lleshi; M. Begeja)................................................................................. 184
Figure 94. 3D Architectural model reworked in rhino v.07 after the survey process (Credits: R.
Qose)........................................................................................................................................ 185
Figure 95. 3D structural model reworked in rhino v.07 after the survey process (Credits: R.
Qose)........................................................................................................................................ 185
Figure 96. 3D photogrammetric model, processed after the on-site survey phase, in the
framework of BIM modeling................................................................................................... 185
Figure 97. BIM Model concept through 3D exploded axonometry models ........................... 186
Figure 98. The Casa del Fascio finite elements model analyzed on ETABS v.19 software .. 188
Figure 99. Theoretical representation of the equivalent strut of infills (based on the
recommendations received from ASCE / SEI 41-06[])............................................................ 189
Figure 100. Behaviour of rc frames under lateral loads scenarios, first - bare frame (flexible
moment frame), primary or predominance rc bare frame performance under the loads; second -
the RC frame + infills, primary and predominant the truss action, the diagram shows the
comparison between the experimental cyclic response of a rc-frame without infill vs combined
one [source: (Tarque & Leandro, 2015)] ................................................................................. 189
Figure 101. Static calculations applied in the design of the structure (more specifically, the
introduction of the calculation methodology; calculation of bending moment, and dimensioning
of the beam section at frames 2 and 3), (Source: AQTN) ....................................................... 191
Figure 102. First mode of vibration considering the whole complex (Etabs v.19) ................ 194
Figure 103. Second mode of vibration considering the whole complex (Etabs v.19) ............ 194
Figure 104. Third mode of vibration considering the whole complex (Etabs v.19)............... 195
Figure 105. First 3 combined modes of vibration according to ETABS.v19 for the case study
................................................................................................................................................. 195
Figure 106. Masonry stress-starin diagrams in the main façade related to the seismic combo
(Etabs v.19).............................................................................................................................. 197
Figure 107. Displacement on the roof, obtained in the framework of static loads (ETABS v.19)
................................................................................................................................................. 197
17
Figure 108. Maximum story Displacement of the building related to seismic combinations
(Etabs v.19).............................................................................................................................. 198
Figure 109. Maximum story drifts related to seismic actions x-y (Etabs v.19)...................... 198
Figure 110. Story shear local force related to seismic actions x-y (Etabs v.19)..................... 198
Figure 111. Story overturning moment of the building related to seismic combinations (Etabs
v.19) ......................................................................................................................................... 199
Figure 112. Story stiffness related to seismic actions x-y (Etabs v.19) .................................. 199
Figure 113. f.e.m. 3d model of the structure prepared for nonlinear analysis ........................ 200
Figure 114. Graphical representation of the modeling of possible plastic hinges before
performing the analysis, as well as their positioning towards the edges. Specifically the
appearance of hinges in the sections on the C and A axis ....................................................... 201
Figure 115. Hinge property data for a selected beam on the left, and for a selected column in
the right, specifically the displacement control parameters, acceptance criteria (plastic
rotation/sf) related to performance levels. General parameters and theoretical behavior of hinges
on beams and columns ............................................................................................................. 202
Figure 116. Generation of capacity curve in V-Δ format according to push-x load, captured in
etabs.v19 .................................................................................................................................. 203
Figure 117. Appearance of plastic hinges in step-20, axis-G, push-y loading in nonlinear
analysis .................................................................................................................................... 203
Figure 118. Appearance of plastic hinges in step-20, Axis-1, push-y loading in nonlinear
analysis .................................................................................................................................... 204
Figure 119. Appearance of plastic hinges in step-20, Axis-3, push-y loading in nonlinear
analysis .................................................................................................................................... 204
Figure 120. Combination of basic steps according to push-y loading and investigations into
possible scenarios of collapse mechanisms ............................................................................. 205
Figure 121. Generation of capacity curve in V-Δ format according to push-Y load, captured in
etabs.v19 .................................................................................................................................. 205
Figure 122. Column C3H13 and C5H13 hinge response diagrams, according to push-Y load
................................................................................................................................................. 206
Figure 123. Column C6H13 and C11H13 hinge response diagrams, according to push-Y load
................................................................................................................................................. 206
Figure 124. Column C15H13 and C21H13 hinge response diagrams, according to push-Y load
................................................................................................................................................. 207
Figure 125. Column C23H13 and C26H13 hinge response diagrams, according to push-Y load
................................................................................................................................................. 207
Figure 126. Hinge response diagrams selected from nonlinear analysis, according to push-x
load (column C1H13, C9H13 hinge and beam B28H1 hinge response) ................................. 208
Figure 127. Column C12H14, C18H13 nad C7H13 hinge response diagrams, according to push-
Y load ...................................................................................................................................... 208
Figure 128. Column C25H15, C24H16 nad C28H15 hinge response diagrams, according to
push-Y load ............................................................................................................................. 208

18
Figure 129. Axonometric model worked in 3Muri software, specifically the western block of
the Building complex which currently belongs to the Dean's Office of the Faculty of Electrical
Engineering.............................................................................................................................. 209
Figure 130. Axonometric model of the western block worked in 3Muri software, where the
transformation of the panels was performed, through the Mesh process ................................ 209
Figure 131. Numerical model of the main facade processed in 3Muri software .................... 210
Figure 132. Numerical model of the back facade processed in 3Muri software .................... 210
Figure 133. +X and -X direction combined capacity diagrams, processed from 3Muri numerical
data .......................................................................................................................................... 211
Figure 134. +Y and -Y direction combined capacity diagrams, processed from 3Muri numerical
data .......................................................................................................................................... 211
Figure 135. Physico-mechanical parameters and characteristics of the recommended
reinforcement layer "Mapegrid g220", according to the database used in 3Muri software
libraries .................................................................................................................................... 218
Figure 136. Crack patterns of the masonry-infilled frame test specimen and crack widths in the
model during the third cycle of loading (positive and negative) (Tarque & Leandro, 2015) . 225
Figure 137. two typical local failure scenarios for RC-frames + infills, (first) RC-frame failure
mode, shear + sliding including diagonal cracks; (second) corner crushing + diagonal
compression failure mode (Asteris & Sophianopoulos, Mathematical Macromodeling of Infilled
Frames: State of the Art, 2011) ............................................................................................... 226
Figure 138. Suggested “masonry infill-frame” separation detail (Hollings 1981); taken from the
paper (Charleson & Vesho, 2020) ........................................................................................... 227
Figure 139. Opera Dopolavoro, elaborate facade fragment accompanied by the layout of the
boulevard ................................................................................................................................. 230
Figure 140. Sketch-concept conceived by Bosio for the design of the building (source: AQTN)
................................................................................................................................................. 231
Figure 141. Main plan of the building, Bosio drawings (source: AQTN).............................. 232
Figure 142. Side view of the building combined with main section-cut (source: AQTN)..... 232
Figure 143. University of fine arts Main façade (source: AQTN) ......................................... 233
Figure 144. Two secondary section cuts of the building (source: AQTN)............................. 233
Figure 145. Back facade of the building (source: AQTN) ..................................................... 233
Figure 146. Survey of the main façade through forogrammetry; sketching of marble panels; and
extraction of the complete model of the southern façade after filling in the missing parts..... 234
Figure 147. Architectural Survey process, facades, doors, windows and 3d-model reworked
(Credits: K. Guraleci) .............................................................................................................. 235
Figure 148. Details and photo collage of the exterior and interior of the building (Credits: H.
Bendaj) .................................................................................................................................... 236
Figure 149. Architectural details extracted from the on-site survey process. Marble staircase
detail, decorative door and frame detail, parapet detail, section-cut atrium detail, decorative
window and frame detail, atrium sketch and interior of the building...................................... 237

19
Figure 150. Architectural plans, sections & facades, re-worked in accordance with original
archival drawings, part of the documentation and digitalization of archival projects (elaborated
by the author) ........................................................................................................................... 238
Figure 151. Analysis panel on the north façade, investigations on a group of degradation issues,
part.01 (credits: Guraleci & Vrenozi) ...................................................................................... 239
Figure 152. Analysis panel on the east main façade, investigations on degradation issues,
part.02 ...................................................................................................................................... 240
Figure 153. Analysis panel on the north façade, investigations on a group of degradation issues,
part.03 ...................................................................................................................................... 241
Figure 154. Theoretical concept of the BIM model for this case, through Exploded Axonometry
................................................................................................................................................. 242
Figure 155. Re-conception and analysis of the structural project according to Bosio (souce:
AQTN) ..................................................................................................................................... 243
Figure 156. Seismic gap detail between two blocks of the building (left), The 2-storey part that
makes the connection between the main block A and the concert hall in block B (right) (source:
AQTN) ..................................................................................................................................... 244
Figure 157. The full complex of the University of Arts campus today and the relevant legend
according to the time of construction. Orientation diagrams on block stratification (Credits E.
Mucollari, K. Como) ............................................................................................................... 244
Figure 158. Photo taken during the construction of the campus of the University of Arts (source:
AQTN) ..................................................................................................................................... 245
Figure 159. 3D F.e.m. model on ETABS v.19 related to main building of University of fine
Arts (author) ............................................................................................................................ 246
Figure 160. Piers failure mechanisms. Diagonal cracks, sliding and bending failure ............ 247
Figure 161. Stress-Strain relationship diagram in compression. Stress-strain diagram for
Uncracked and cracked masonry panel cross section .............................................................. 247
Figure 162. Moment curvature and Shear displacement curves equivalent for piers panel ... 247
Figure 163. Diagram of design spectrum used for seismic analysis and simulations ............ 249
Figure 164. First mode of vibration from modal analysis (ETABS v.19) .............................. 250
Figure 165. Second mode of vibration from modal analysis (ETABS v.19) ......................... 250
Figure 166. Third mode of vibration from modal analysis (ETABS v.19) ............................ 251
Figure 167. Stress S1-1 and S2-2 distribution on the main façade, according comb-1 (ETABS
v.19) ......................................................................................................................................... 252
Figure 168. Stress S1-1 and S2-2 distribution on the main façade, according comb-2 (ETABS
v.19) ......................................................................................................................................... 253
Figure 169. Story displacement diagrams, according to seismic comb-1 and comb-2 (ETABS
v.19) ......................................................................................................................................... 254
Figure 170. Story drifts diagrams, according to seismic E-x and E-y (ETABS v.19) ........... 254
Figure 171. Story shear force local diagrams, according to seismic comb-1 and comb-2 (ETABS
v.19) ......................................................................................................................................... 255
Figure 172. Story overturning moment diagrams, according to seismic comb-1 and comb-2
(ETABS v.19) .......................................................................................................................... 255
20
Figure 173. Architectural model created in 3Muri software, axonometric view of the structure
................................................................................................................................................. 256
Figure 174. Presentation of two axonometric front views of the model created in 3Muri software
................................................................................................................................................. 256
Figure 175. Numerical model according to the equivalence performed in 3Muri software,
axonometric view of the block at two different angles ........................................................... 257
Figure 176. Numerical model according to the equivalence performed in 3Muri software, view
of the main facade positioned in the east direction ................................................................. 257
Figure 177. Numerical model according to the equivalence performed in 3Muri software, (a)
view of the facade in the position of the connecting block, (b) view of the front facade ....... 258
Figure 178. Summary table of capacity curves V-Δ, extracted in combination by 3Muri software
for 24 analyzes performed in both seismic directions ............................................................. 258
Figure 179. +X and -X direction combined capacity diagrams, processed from 3Muri numerical
data .......................................................................................................................................... 259
Figure 180. +Y and -Y direction combined capacity diagrams, processed from 3Muri numerical
data .......................................................................................................................................... 259
Figure 181. Interconnection of systems, explained in data file networks, referring to the second
case .......................................................................................................................................... 271
Figure 182. Summary diagram on the generated outputs for the 3 case studies, according to the
methodology proposed in this thesis ....................................................................................... 273
Figure 183. National theatre location and positioning with the central square (Menghini ,
Pashako, & Stigliano , Modern Italian architecture for the cities of Albania, 2012) .............. 282
Figure 184. National theatre ground floor plan, main façade view and technical details of the
structural project (Menghini , Pashako, & Stigliano , Modern Italian architecture for the cities
of Albania, 2012) ..................................................................................................................... 283
Figure 185. National theatre structural details and “populit panels” used on structural masonry
(Ermanno Tunesi, 2019) .......................................................................................................... 283
Figure 186. National theatre project details and building evaluation (Menghini, Pashako, &
Stigliano, Architettura Moderna Italiana per le citta d'Albania, Modelli e interpretazioni, 2012)
................................................................................................................................................. 285
Figure 187. The National Theater finite elements structural model analyzed (SAP2000 V.22)
................................................................................................................................................. 289
Figure 188. Elastic demand spectrum, referring Tirana ground parameters (SAP200 V22) . 290
Figure 189. First 3 modes of vibration according to SAP2000 V22 for the case study ........ 291
Figure 190. Modal data, frequencies and seismic parameters, obtained from the technical report
generated in the software (SAP2000 V22) .............................................................................. 291
Figure 191. Main stresses distributed on the surfaces taken in the study (SAP2000 V22) .... 292
Figure 192. Distribution of stresses in the longitudinal I of the building, according to the two
components σx and σy (SAP2000 V22) .................................................................................. 292
Figure 193. Architectural survey, in the framework of data processing related to the BIM model
................................................................................................................................................. 294
Figure 194. Diagram related to the analysis of urban planning of the area between periods . 295
21
Figure 195. Simulations of local failure mechanisms, analyzed position "northern side facade"
................................................................................................................................................. 296
Figure 196. Simulations of local failure mechanisms, northern side façade. 3D view in the
context of possible collapse scenarios ..................................................................................... 297
Figure 197. Simulations of local failure mechanisms main western facade, combined diagrams
in the framework of possible collapse scenarios ..................................................................... 298
Figure 198. Simulations of local failure mechanisms north side facade, second typology of
possible collapse scenarios ...................................................................................................... 298
Figure 199. Architectural survey, main facades reworked for digitalization process (Credits R.
Qose, A. Abdullaj) ................................................................................................................... 299
Figure 200. Architectural survey, pieces from the BIM model & details reworked on Rhino
v.07, part 1 (Credits: R. Qose, A. Abdullaj) ............................................................................ 300
Figure 201. Architectural survey, 3D model & details reworked on Rhino v.07, part 2 (Credits:
R. Qose, A. Abdullaj) .............................................................................................................. 301
Figure 202. Architectural survey of windows, doors and arches ........................................... 302
Figure 203. Careful sketching in detail stone by stone, mortar joints, façade elements and details
................................................................................................................................................. 302
Figure 204. Analysis and investigation of the current condition of facades, pathologies and
degradation; left survey of architectural elements ................................................................... 303
Figure 205. Architectural survey of the facade in the framework of the investigation of
pathologies, cracks distribution and fractures ......................................................................... 304
Figure 206. Collage of photos showing the current state and degradation of the material into
different elements .................................................................................................................... 304
Figure 207. Processed diagram, based on laboratory data, showing the mold content in the main
facade tiles ............................................................................................................................... 304
Figure 208. Material degradation analysis and photogrammetric processing of facades, in the
framework of Bim modeling (credits S. Agalliu, B. Ndoja) ................................................... 305
Figure 209. Column C12H14, C18H13 nad C7H13 hinge response diagrams, according to push-
Y load ...................................................................................................................................... 306
Figure 210. Column C25H15, C24H16 nad C28H15 hinge response diagrams, according to
push-Y load ............................................................................................................................. 306
Figure 211. The first simulation in the framework of the investigation of local mechanisms of
perimeter side panels, the scenario of possible mechanisms ................................................... 307
Figure 212. The second simulation in the framework of the investigation of local masonry
mechanisms related to the ground floor masonry, the scenario of possible local mechanisms
................................................................................................................................................. 307
Figure 213. Analysis on the urban planning of the area between 2 periods, project identification
................................................................................................................................................. 309
Figure 214. Architectural survey process, sketches of interior elements "windows" and
constituent elements ................................................................................................................ 310
Figure 215. Architectural survey process, sketches of interior elements "doors" and constituent
elements ................................................................................................................................... 311
22
Figure 216. Analysis of the main facade against fractures in marble and moisture content .. 312
Figure 217. Analyzes on the condition of the masonry, the distribution of mold, parasitic
vegetation and blackening of marble ....................................................................................... 313
Figure 218. Simulations in the framework of the local mechanisms investigations, mechanism
one ........................................................................................................................................... 314
Figure 219. Simulations in the framework of the local mechanisms investigations, mechanism
two ........................................................................................................................................... 314

23
Questa pagina è stata lasciata intenzionalmente vuota
List of tables

Table 1. Compressive strengths for brick walls, with row height over 12cm (KTP-78) .......... 80
Table 2. Compressive strengths for concrete block walls, with row height over 18cm (KTP-78)
................................................................................................................................................... 80
Table 3. Compressive strengths for stone walls and foundations with kave stones (KTP-78). 80
Table 4. Calculation resistances in central traction and shear (KTP-78) .................................. 80
Table 5. Elastic characteristics of masonry, “α” (KTP-78) ...................................................... 81
Table 6. Orientation ratio by volume of mortar components for mortar brands....................... 86
Table 7. knowledge levels according to Eurocode 8, part.3 (CEN Eurocode 8, Eurocode 8:
Design of structures for earthquake resistance Part 3: Strengthening and repair of buildings,
2003) .......................................................................................................................................... 94
Table 8. Elastic spectrum parameters according to EN1998-1 for categories of lines Type 1:
A,B,C,D,E................................................................................................................................ 104
Table 9. Combination values related to load types ................................................................. 112
Table 10. Table with mechanical parameters of masonry materials after performing laboratory
tests, specifically tests in compression of cubic samples of red brick and silicate-white (Altea &
geostudio, 2019) ...................................................................................................................... 139
Table 11. Modal participating mass ratios and periods (ETABS, 2019) ................................ 142
Table 12. Summary table of results obtained, after performing nonlinear analyzes on 3Muri
v.13 software ........................................................................................................................... 154
Table 13. Technical data according to Kerakoll quality standard (Kerakoll, 2021) ............... 168
Table 14. Configurations used for reinforcements, presented in the plan and facade ............ 169
Table 15. Summary table of results obtained after reinforced building simulations .............. 171
Table 16. Table of mechanical data of laboratory tests, developed for this case study (Altea &
geostudio, 2019) ...................................................................................................................... 190
Table 17. Summary table of cross sections of columns and beams, as well as specification of
reinforcement (drawings are worked on etabs) ....................................................................... 192
Table 18. Modal data, frequencies and seismic parameters (ETABS v.19) ........................... 196
Table 19. Modal Participating Mass Ratios and period (ETABS v.19).................................. 196
Table 20. Summary table of results analyzed in 3Muri software, focused on the most
problematic steps ..................................................................................................................... 212
Table 21. Technical data according to Mapei quality standard (Mapei, 2019) ...................... 218
Table 22. Graphic representation of configurations in plan and height of reinforcing elements
................................................................................................................................................. 219
Table 23. Summary table with data obtained after reinforced structure simulations, value
comparisons ............................................................................................................................. 221
Table 24. Table of mechanical data of laboratory tests, for third case study (Altea & geostudio,
2019) ........................................................................................................................................ 248
Table 25. Modal periods and modal participating mass ratios (ETABS v.19) ....................... 251
Table 26. Summary table of results obtained by 3Muri software, focused on nonlinear
simulations of the most problematic steps ............................................................................... 260

24
Questa pagina è stata lasciata intenzionalmente vuota
Symbols and Abbreviations

• Symbols

E modulus of elasticity;
G the shear modulus;
ν Poisson’s ratio;
V shear force;
VEd design shear force in a wall;
VRd the design shear capacity;
MEd design bending moment from the analysis for the seismic design situation;
MRd the resisting bending moment;
fb normalized “compressive strength of masonry” units;
fk the “characteristic compressive strength of masonry;”
fm compressive “strength of masonry mortar;”
ft tensile “strength of masonry;”
fvd design “shear strength of masonry;”
fvk characteristic “shear strength of masonry;”
fxd design “flexural strength of masonry” having the plane of bending;
EI stiffness;

σ normal stress;
τ tangential stress, shear stress;
ε is the symbol of deformation (or relative deformation);
εmu compressive boundary deformation of masonry;
d displacement;
dt the target displacement of the Multi Degree of Freedom MDOF system (EN
1998-1: AnnexB B5);
dm the ultimate displacement of the Multi Degree of Freedom MDOF system (EN
1998-3: C.3.3 [2]);
γM partial masonry resistance factor, according to the Eurocode standard;
γ specific weight of materials;
Γ the transformation factor into an idealized equivalent system with one degree of
freedom, EN 1998-1 : Annex-B B2-(B.3);
Φ the standard normal cumulative distribution function;

T vibration period of a linear single degree of freedom system;


T1 fundamental period of vibration of a building;
TB “the lower limit value of the period”;
TC “the upper limit value of the period”;
TD “the constant defining value of the upper limit of the period”;
Se(T) elastic response spectrum;
Sd(T) design spectrum;
T* the period of the idealized equivalent SDOF system;
d*m the ultimate displacement of the idealized system (SDOF);
CF confidence factor of the material;
γk k-th modal participation coefficient of the construction;
αg design ground acceleration on type A ground;
αgR reference peak ground acceleration on type A ground;
25
g acceleration of gravity;
S soil factor;
q behaviour factor;
η damping corrector factor;
m* mass of the equivalent SDoF system;
ξ viscous damping ratio (in percentage %);
CMi center of mass;
CTi center of torsion;
αNC the seismic vulnerability index (Near Collapse) 3Muri software;
αDL the seismic vulnerability index (Damage Limitation) 3Muri software;
αSD the seismic vulnerability index (Significant Damage) 3Muri software;

• Abbreviations

FEM the finite element method;


FEA finite element analysis;
BIM building information modeling;
H-BIM heritage building information modeling;
DLS damage Limit State;
ULS ultimate limit state;
SLS Serviceability Limit State;
CSM Capacity Spectrum Method;
S.D.O.F the single degree of freedom system;
M.D.O.F the multi degree of freedom;
PGA peak ground acceleration;
KTP Albanian design technical conditions;
IGJEUM Institute of Geosciences, Energy, Water and Environment;
AQTN Central Technical Archive of Construction, Tirana;
EN 1996 Eurocode 6: Design of masonry structures;
EN 1998 Eurocode 8: Design of structures for earthquake resistance;
FRCM Fiber Reinforced Cementitious Matrix;
FRP Fibre-Reinforced Plastic;
CF Confidence Factor;
MPa Megapascal (unit of measurement);
kN kilo Newton (unit of measurement);
kNm kilo Newton * meter (unit of measurement);
URM Unreinforced masonry;
RC Reinforced Concrete;

Technical symbols, as well as other engineering abbreviations that are specific to paragraphs,
sketches-images or special equations, are explained in detail in the relevant paragraph of the
theoretical part

26
ABSTRACT

The history has left its mark on the Albanian culture and society, from the Roman Empire, Greek
colonies, Turkish Empire, to the Balkan and World Wars. Indescribable are the traces and
influence of Italian architects and designers between 1920 and 1940. The architecture of the
center of Tirana, reflected mainly along the main boulevard that divides the city into two parts,
is an undeniable proof of the symbiotic process that has always characterized the relationship
between Italian and Albanian culture in all dimensions.

By researching and analyzing the materials found in the technical archive of Tirana, also, the
Italian Luce Institute, specifically in the archives of L. Luiggi, G. Fiorini etc., it helps to better
understand the Italian vision for Tirana. Today, these sketches and drawings serve as a point of
reference for architects, engineers and restorers, as long as buildings need reconstruction or
intervention.

After the Second World War, these buildings were perceived as signs of a foreign invasion, but
over the last 30 years, superstitious ideologies have been replaced by a more peaceful evaluation
process. Built during the 20-40s for other purposes, after liberation they took other functions,
from universities, study centers, headquarters and ministry facilities, thus becoming an
inseparable part of the day-to-day and historic part of the city, intertwined and in cooperation
with each other. Now this historical-architectural heritage, that is shared among people, has
helped to change the initial perception.

This cultural heritage buildings of Tirana’s case provide structures and monuments of great
value, since they are proof of historic forms of life and the history of modern societies, and show
the existence of a tangible cultural identity. The architectural heritage adds character to its
surroundings, is an integral part of the city, and is also a valuable tourism resource. Nowadays,
architectural and cultural legacy are regarded as a perishable and valuable resource that must be
protected and passed on to future generations. However, protective programs are not always as
effective as they may be, owing to a lack of interest on the part of residents, professionals and
an unfavorable socioeconomic climate.

Performance of cultural heritage “buildings after earthquakes is the concern of people and many
professionals from different disciplines”. Although, everyone supports for protecting these
architectural masterpieces from seismic threats, the predicted loss to their aesthetic values (as a
result of additions and retrofitting processes) “hinders a required decisive consensus on whether
or not an action should be taken to save these national treasures. This could be due to a lack of
agreement on how to value the added value of seismic risk reduction on the building as a result
of structural strengthening” compared to the damage values related to any particular seismic
retrofit technique.

The age of these buildings is approaching 100 years, which makes us aware of the greatness of
the designers of that period. In this regard, this study aims to define the principles and secrets
of structural simplicity and to interpret theoretically their structural arguments. Plan and height
configurations, the most useful structural elements of the period and the ability to withstand a
large number of seismic events.

27
The strategic vision of the study is to develop a detailed methodology which can serve as a
manual for addressing the issue of restoration, as well as addressing the issue of structural
analysis of cultural heritage with the principles and international charters on restoration.
Theoretical analyzes and interpretations of the architectural solutions of the period will be
developed. The main goal is to treat the complicated modeling of buildings of the past, using
the building information modeling methodology as a tool that helps us improve the methods of
evaluation and parametric interaction. Regarding the proposals for intervention, it will be
attempted through this methodology, to create a controlled space monitored by experts, to
prevent damage to architectural assets during restoration.

The study will be carried out through theoretical approaches initially and literature research,
while later the methodology will take shape through the treatment of some cases of studies,
which have not been previously studied in this specific context. The Albanian context has shown
a lack of cooperation in a team of experts or governments have made this contribution even
more fragile. To achieve this goal, the right atmosphere of cooperation between experts must be
created, to consider their diverse perspectives. On the other hand, this research aims to raise
awareness of Tirana's cultural heritage past by fostering a debate on cultural heritage and its
future within a structured heritage framework. The study tends to stimulate the process of
digitalization by creation of 3d models including BIM, in such a way as to create accessible
database of materials, elements, combined architectural and structural models, database for
additions and retrofitting’s.

Also, in this study will be targeted to overwhelm the curiosity of researchers, students, aspirants
of doctoral studies or lovers of cultural heritage who want to know more about the architectural
and engineering part of the main buildings that marked the 20th century architecture of Albania.
Those buildings that surround us today define the spaces of our cities which still more tell us
how we were, how to judge the past and above of all how we can project the future.

28
CHAPTER 1.
Introduction

29
1.1 Extended Introduction

This study will initially focus on the context of Tirana's cultural heritage buildings, designed
during Italian influence at the period 1920-40s, literature and data collection, “also analysis,
which will be further compared with the European context, Italian architecture and with similar
cases in content. Tirana represents a very special occasion, unique in terms of intertwining the
Italian architectural design, combined with Albanian motives and details. This feature of this
category of buildings has resulted from many political, economic and social factors of the time
that radically changed the way of vision and architectural conception in the Albanian capital. It
has been a long time since that period, now the urban-architectural and construction vision of
modern Tirana is changing, but it still preserves the most valuable part of the assets and the
beauty of the old architecture.”

During the period 1920 to 1940, a group of Italian architects, or rather designers reviewed
existing urban plans and proposed new and more efficient plans for Albanian cities. The Italian-
style architectural heritage and its monumental structures designed during the 1920s in Albania
possess precious architectural and cultural elements that must be preserved and promoted, and
to achieve this, we can begin by first identifying and presenting them to the community, also a
wider range of professional stakeholders and experts. Through the treatment of this study, some
of these buildings have been identified and selected, the research focuses on buildings with
institutional functions, highlighting their architectural qualities through analysis, investigations
and modeling in addition to engineering performance. Through the cases of study on the
typology of buildings the aim is to explain and know the design morphology, materials,
architectural survey, data collection and BIM modeling. The data of this study will serve for
future restoration interventions, in order to help re-evaluate the architectural and urban
landscape.

Looking over Albania territories, many professionals are surprised by the big quantity and the
quality of this architectural heritage for which have left traces among the best Italian architects
and engineers of that period, each with their own skills and militancy in the movements of that
time. These designers can be placed within a well-defined cultural "map" that reflects the great
ideological aspirations of their country, “the spirit of the beginning of the twentieth century,
Eclectism, Rationalism etc.”. The “historical period considered is marked by a rich production
of projects, sometimes realized, in some cases not, which have however produced a trace in the
imagination of the citizens, often marking a drastic change in the way of "living in the city",
closely linked to politics and to the ideology of power.”

The current situation of these buildings today can be considered problematic in terms of urban
performance. During this period in Tirana, an urban-plan is being implemented where it
considers the vertical and horizontal expansion of the city, extending in three new rings.
Approximately within 2030 the city it will extend to 4 rings. Also, the current city of about 1
million citizens anticipates a progressive increase in the coming years, this has given priority to
the government for "expansion, urban planning and infrastructure". “Referring to the buildings
in the study we can say that they are also neglected in terms of structural performance aspect.
These buildings, being positioned in the central axis, are also considered the assets of the city,
so, have been constantly maintained to their façades in aesthetic terms, mainly” in painting and
plastering. There has never been an in-depth scientific study regarding their structural
performance as well as seismic consolidation projects. “Apart from this, no structural engineering
30
studies have been carried out over the years, on the capacity and current state of their
construction. Currently, there are no in-depth, accessible computer models with complete data
on these buildings (with a time file) including their architectural or engineering point of view.”

The main difficulty as well as dilemmas related to 3d models dealing with “seismic rehabilitation
of historical monuments is the dominance of ambiguous data but compelling values of the
structure model that comes across with the transparency and ease of structural (or seismic)
engineering techniques and technology in reducing seismic hazard risk on old buildings. The
gap between these two different classes of problems is similar to the known gap between art and
science and their reconciliation can be achieved only based on morals and theories.”

The “inherent value of architectural heritage buildings is indebted to their originality and
authenticity, matured appearance and the charm of their designer impression. None of these
values have a real substitute, or any solution in our contemporary life and any damage to these
architectural assets cannot be authentically restored. This is, perhaps, the main reason for our
nostalgic sentiments toward any change, modernization or restoration in these category of
buildings. Accordingly, architects, engineers, archeologists, historians and those institution
responsible for cultural-historical aspects of the society have developed a kind of sensitive
attitude against any restoration strategy for these treasures. In many similar cases, this attitude
has reached to a 0-tolerance level if restoration program for the building suggests strengthening
the whole system beyond its authentic capacity” . In many literatures, “it's always argued that
the great designers of the past” have accomplished creation of a "perfect building" and there is
no need for strengthening of such structure for a long time. “But it must be admitted that this
argument does not serve the reality and our precious buildings need to be studied, investigated
and simulated many unfavorable scenarios, seismic risks or beyond” .

Obviously, “seismic rehabilitation in cultural heritage structures causes damage to the


originality, impression and beauty of the building and should be done, only, if there is a real
necessity, such as when structural stability” is compromised. “When these monuments are
located in a region prone to earthquake hazards, the task of the researcher or architect is not to
preserve the historical values of the building only at this time, but to extend these values to a
longer time span. This can be accomplished in the most efficient way, only if very detailed
numerical and graphic models are created, to enable many simulations, scenarios and scientific
cooperation between disciplines” . Actually the experts should try to rationalize the concept of
historical values. In fact, there is a need to add another dimension to the concept of historical
values, their life expectancy regarding the earthquake hazard risk in the Balkan region, carefully
analyzing risk factors, reliability coefficients, but not only. Without ignoring the problems of
the age of the structure, the degradation of materials or atmospheric conditions which directly
affect the performance of structures. So, if historical values can survive longer “considering all
the above risks” “they should be considered more valuable through multidisciplinary modeling”.

In this way, “addressing the issue of scientific studies related to these buildings beyond the
aesthetic or transitory threshold, including seismic or all risks may add to the historical values
of the city and can increase efficiency of the issue of restoration” . This requires weighing the
current historical values together with that after the interventions strategy “when contemporary
architectural values are reduced but their life expectancy improved”. “Such weighing procedure
eventually leads us to a consensus on whether the interventions or seismic retrofit plan should
be recommended or not according to each specific case. In general terms there must be a well-
31
organized interaction between structural engineers, architects, archaeologists, and so on to take
their views into the consideration” “regarding the damage tolerance” and prepare not to stick to
a predefined level of structural & seismic hazard risk for cultural heritage buildings. This is
something difficult in theoretical and applied terms, but a methodological basis which can be
advanced through computer modeling can minimize the current gap in this issue.

One of the aims of this topic is to assess the current performance of architectural heritage
structures, based on the current scientific knowledge mainly of seismic discipline, summarized
in literature, guides, codes and standards, through a conservative process of "research,
architectural survey, site investigations, BIM-modeling and simulations", without neglecting the
theories of restoration, the basic concepts of international restoration charters.

The primary purpose in dealing with this issue, closely related to the study of Cultural heritage
Buildings in Albania is to raise the awareness at the academic level initially, starting with
practical guidance to improve theoretical and applied methodology for conservation and
restoration practice. It aims to assess the performance of these buildings, and also to evaluate
and compare their seismic performance in their existing state even according to the requirements
of Eurocodes.

Primary vision with announced objectives of the study is to develop a methodology which will
help the process of research in the field of restoration in Albania to be improved. This will be
made possible through an input-output system serves in the form of a manual in academic rank
for addressing the issue of cultural heritage restoration, collaborating and combining with
engineering fields, maintaining an immovable pillar of architectural principles and postulates in
implementation.

Structural interventions on historical buildings, must be carried out with great care and
sensitivity if important special features of the buildings and its essential historic character are to
be properly safeguarded. In the first instance, it is therefore always advisable to do plenty of
research and obtain the right advice.

Today there are a lot of solutions or intervention techniques on the market, that are well suited
to the needs of reversibility and low invasiveness on existing buildings. These tangible
contributions are the result of a lot of researches and technological innovation in the academic
environment. Regarding this fact, the aim is to further advance this current research product,
addressing specific cases such as Albania, conclusions which may contribute to the regional or
global context.

Appropriate refurbishment of cultural heritage buildings and their structures is a crucial part of
their conservation to ensure they have a safe and sustainable future. Improving the performance
of buildings and protection of the historic environment through a careful and critical process,
with more research activities and modeling, are therefore strong objectives.

In the elaboration of this thesis, three main cases are treated in detail, including a fourth case
theoretically treated in the annexes. Starting with Municipality of Tirana building was dealt
with, a historic masonry building from the early 1929s which during the first half of the 1990s
underwent an expansion to accommodate other municipal offices; continuing with the analysis
of the Complex of buildings of the Polytechnic University, a typical building of 1940, with the
32
first application of the brick masonry mix system combined with RC moment frames; and
closing the application phase with the University of the Arts building, a 1939 complex combined
between 3 buildings, accompanied by some interesting structural solutions that will be addressed
in detail in chapter 6.3. Meanwhile, in the annexes of the study, the fourth case of the building
of the National Theater, which is demolished in 2020 to make way for a new multifunctional
building, is treated in a concise manner with some findings.

The cases were treated in the framework of the architectural and engineering study, initially
mentioning the architectural surveys accompanied by archival or field investigations,
organizations of scientific works through academic courses of restoration, student workshops,
data collection, engineering context with BIM models, equivalent models, parametric models
related to Heritage content, experimental analysis phases and simulations for each possible
scenario and finally concluding with some graphic products and recommendations which tend
to contribute to the field of restoration.

Research-related issues on restoration and conservation has recently gained a lot of attention in
many countries, including the great progress and achievements of architecture, executing
preservation, protection, retrofitting, maintenance and restoration of immovable cultural
heritage in a standardized way.

1.2 Aims and Objectives of the thesis

The purpose of the study is to address a detailed methodology which can serve as a manual for
the issue of restoration, survey & digitization of archival projects, theoretical interpretations of
the structure accompanied by simulations and collapse scenarios, as well as addressing the
structural issue of cultural heritage with principles or restoration charters, to limit them to a
controlled space, to prevent damage to architectural assets. This will be realized through
theoretical interpretations initially and then by treating 3 cases of previously undocumented
study (in this context).

To achieve this, one of the objectives is to have a well-organized interaction between structural
engineers, architects, archaeologists, “and so on to take their views into the” consideration
“regarding the damage tolerance” “and prepare not to stick to a predefined level of seismic
hazard risk for historical buildings”. We emphasize that so far, the spirit of cooperation in
Albania is fragile. Much more damage has been done in terms of cultural heritage and the stated
objectives tend to reduce this distance between experts.

• One of the objectives of this topic is to assess the performance of buildings with
historical value, based on the current scientific knowledge of seismic field, summarized
in literature, guides, codes and standards, without neglecting the charm of their
architecture, and the historical aspect.

• Interpretations and debate on construction techniques and technologies used by


designers in the period 1920-40.

33
• One of the objectives related to the time context in which we face today, is related to the
necessary process of digitization and creation of parametric models by applying BIM, in
such a way as to create accessible files for other researchers, with a database of materials.
, architectural elements, equivalent structural models intertwined with the architectural
one, documentation of interventions or additions, time timeline of the building through
modeling (authentic modeling in the design period and current).

• Another objective is the investigation of the structural arguments that have been taken
into account in the design, the design codes, the physical-mechanical parameters of the
materials, the seismic parameters and certain coefficients. Not forgetting the analysis on
calculation reports.

• The issue of rehabilitation of cultural heritage buildings in Albania is an objective to


raise the awareness, practical guidance to achieve good conservation and restoration
practice. It aims to assess the seismic performance of these buildings, and also to
evaluate and compare their performance in their existing state even according to the
requirements of Eurocodes. This should be done through literature review and taking
into account the principles and theories of restoration, mainly proclaimed by
international restoration charters.

The issue of treatment of cultural heritage is complex and must be treated with special care,
regarding the aesthetic and historical value. So far, many consolidation interventions, additions,
or restorations have been performed on these objects which have left traces. Rapid and routine
treatment, lack of diagnostics or the need for consolidation without a proper project, lack of
opposition or conservative review has done significant damage to the Albanian cultural heritage.

• This makes us aim to review any restoration, addition or consolidation project, regarding
the sensitivity of the restoration & conservation principles and not to allow erroneous
interventions in such buildings. This objective requires specific recommendations and a
very detailed methodology, on the steps that must be followed to address it. Theoretically
this is addressed in the methodology section, where it is shown and graphically how it
can be applied.

• One of the long-term objectives that this study aims to create is the inclusion or linking
of restoration techniques in programs that apply BIM. This is currently being applied in
some countries, mainly in terms of documentation, digitalization and virtual reality. But
the issue of interference is not included in these applications. The purpose of this method
is to prevent erroneous interventions, by being reversibly parameterized in programs that
apply BIM. Wrong interventions can be corrected or made effective based on parametric
recommendations that satisfy the principles of restoration (or international charters).
This objective begins to be discussed and theoretically systematized in this study and
remains open for later post study or collaborations between experts of the disciplines
involved.

34
1.3 The research questions

• The question that will lead the research is whether the architectural restoration and the
anti-seismic retrofit of these buildings can be the meeting point between the interests of
architects, structural engineers, monuments restorers, government and residents of
Tirana, mixing the charm of Italian architecture with the modern vision of Tirana for the
future.

• It’s always argued that great designers of the past “have realized the perfect structural
and architectural building. But, is enough this conservative view enough, in the actual
reality, not to intervene with a genuine seismic retrofit” in these buildings?

• What were the most popular typologies of Italian architecture during the period between
the 1920s and the 1940s? What role does the structural and architectural typology of
these buildings in the vision and priorities of modern urbanism apply?

• How to renovate the structure and increase the seismic performance of these complex
typologies without affecting their aesthetics, which carries historical value? If the
question is better re-formulated, the main problem appears in the fact, how to intervene
in the object without damaging its aesthetics and architecture, how to integrate with
additions made in different periods, and the most importantly “how to find a
mathematical non-linear connection to link pre-conceived engineering f.e.m.
simulations or collapse scenarios with restoration theories / principles?”

• How have these buildings evolved over the years, the architectural exterior aspect or
different design modifications in function of their use and function?

• How can the issue of additions be addressed through interpretations of Brandi theories?

• Regarding the current dynamics of the city, in the framework of new constructions and
towers near the cultural heritage objects, the question arises “what are the main
challenges that form the key reasons for the preservation of existing heritage places”?

The following sub-questions were elaborated to provide guidance throughout the research
trajectory:

• What are the phases of a genuine retrofitting project?


• What are the most common actors involved in the retrofitting project?
• How can the project management process be improved for more effective management
in the operation and delivery of heritage building projects?

1.5 Methodology, stages and concept diagrams on the proposed system framework

The research started from the complete study of all archival materials and old or contemporary
literature based on these objects. Sources have been works written in Albanian, Italian, articles
of symposiums and conferences, writings of foreign authors, experts and scientific reports. In
35
them, attention is focused on the architectural point of view combined with structural system
interpretations in general and aspects of BIM modeling and simulations in each selected case in
particular. The theoretical explanation followed and the methodological context of this study is
done on some general theoretical stages as follows:

Phase 1 “Theoretical bases, principles and charters of restoration, engineering interpretations”.


This is a long phase covered throughout Chapters 2-5, which theoretically addresses all the
architectural bases and principles of heritage restoration & conservation, Brandi C. theories,
restoration cards and theoretical analysis on them. At this phase, specifically in chapter 3-4 are
treated the basic theoretical engineering concepts on materials, masonry, and seismic
engineering accompanied by the respective calculations and parameters. The evaluation on the
design codes of the period, compared to the current codes and the Eurocodes are also treated.

Phase 2 “Historical values identification and manifestation”. Initially, “rehabilitation of


historical building start with a qualitative appreciation related to the values of the structure”
and its materials. “However, in the case of seismic retrofitting and rehabilitation process, these
values should be quantified carefully in order to be able to continue the process. This phase
will be realized with great care and by consulting step by step with experts in the fields of
architecture, engineering and archeology, for preserving the architectural and historic values
and impressions of the building. To have a simplified guideline”. The process of recognizing
historical values can not be done completely without being completed and with the context
drawn in the second phase of architectural survey, but considering the cyclical interaction
between the phases, more favorable conclusions emerge.

Phase 3 “Architectural Survey, documentation, archival digitization, collection of material and


model selection criteria”. This is one of the main phases of this study. This phase is briefly
managed in theoretical aspects and then adapted to each case study analyzed in Chapter 6.
Collection of visual documents and reports, photos, archival drawings, graphics, previous
architectural surveys, additions and their projects or documentation, models and recent
intervention projects.
These documents were provided on the basis of the central technical archive of Tirana, on-site
architectural survey, interpretations and confrontations from literature, publications, books and
scientific articles, and then systematized taking into account:
• Determining the date of taking the photo, sketch or survey;
• Verification, through direct viewing of the building, site architectural survey to
investigate changes with the current situation or with other visual and archival
documents;
• The process of orthogonal photography with a drone, or the use of a laser scanner and
then the processing of these phases through photogrammetry;
• Placing in chronological order to enable the results in their historical evolution, whether
or not there were changes or interventions in time, or whether there were pre-existing
structures in the same place;
• Analyze and create the transition or timeline of the building;
• Digitization of archival drawings in cad format;

36
• 3d modeling of buildings (model of the authentic building at the time of design and the
current model of each building), the emphasis is on BIM modeling;
• Analysis on the degradation of the facade material, problems with humidity, mold,
fractures and cracks of the masonry panels.

Direct examination and interpretations of the work – reflections and analyzing typological
details.
This inspection has been done several times and has been done documented through photos and
sketches. Detailed analysis of additions over the years, why these additions were made and how
they affect the performance of the structure. It is analyzed whether these additions are carried
out in accordance with the principles of architectural restoration. During this observation will
be documented:
• Distinctive construction and architectural phases through theoretical analysis;
• Status of the monument, the current architectural value of the building;
• Materials and physical-mechanical properties of materials used for construction, to
better understand the building and the structural performance of buildings;
• Small details of the architecture and constructive details of the building and ways of
working the material, in-depth analysis of facades;
• Additions, floors or side additions. Change, or not, of the compositional form of previous
interventions in facades, reconstructions or different phases of construction;
• Investigations on the additions, the function of the additions and their documentation in
the historical timeline of the building. Theoretical interpretations on the architectural
style of the additions.

The selection criteria of buildings became related to the necessity to analyze and investigate on
different typologies of this period. The objects themselves have their own features and
interesting points to be analyzed and discussed. Based on the found materials and the analysis
made to each building of the architectural typologies, it was decided that the study would focus
on engineering analysis and seismic performance first, and then analyzing with the architectural
context and some of the principles of architectural restoration. The building of the Municipality
of Tirana with masonry structures were analyzed first and then the building of the Polytechnic
University, and at the end the building of the University of Arts, which have more complex
structures. These are discussed in detail and constitute the core of this study. The case of
National Theater (demolished now[1]), is treated briefly in the annexes of this study.

An important part of this phase is the creation of bibliographic files, known as “A digital
database about all the elements of the cultural heritage building”. During the reading of the
relevant bibliographic files and archival reports found in projects, are created which are not
based, as usual, on the data of a book but summarize, according to the typology. These
bibliographic files contain data on the time of construction, writing references, materials
parameters, calculation reports, what was written about it and how each author or designer
comments on the typological work/project, compositional or constructive data and what original
literature contribution the author brings, graphic data of the writing as architectural plans,
altimeter sections, details or sketches.

1
The National Theater building complex was demolished in 2020 by the local authorities (on conclusions of the
degraded structure and the needs for a new building with more space), to build a new contemporary building.
37
Regarding the methodology, it should be noted that in addition to theoretical and archival-
collection work, this second phase will be carefully realized through the interaction of experts
in the fields of architecture, engineering and planning, through the subject of "Cultural heritage
restoration". So the coordination of academic experts and coordination of work with
architecture and engineering classes at Polis University, with the course which is applied in
the 4th year, is the basis for the development of the on-site research phase. The students worked
on the guidance of the lecturers of the course to process the archival material and to make
verifications or field survey processes near the selected buildings. The work has been strictly
monitored and directed to bring out a good digital base of this phase. Furthermore the specific
work of each group is explained specifically for each case in Chapter 6.
Phase 4 “3D modeling, f.e.m. analysis, seismic simulations and investigation of possible
collapse scenarios”
In order to accomplish such a task, the design of three-dimensional finite element models and
simulations must be an integral part of this research. The basic concept will be the conversion
between the architectural model and the structural 3D model. “Two types of model conversion
are targeted. One is for linking architectural models and structural models together, another is
for linking among structural analysis applications. The first model will represent building
geometry and appearance representation while a structural model will include all structural
elements involved in vertical and lateral load transferring.” Through this BIM model, it pays
attention to the details mainly on the facades, so we cannot overlook any detail in the 3D
modelling, which should be as close to reality, representing the charm, beauty and even the
damage that has been carried through the years. The second model is associated with the
equivalent structural and analytical model to undergo seismic analysis. Care has been taken to
investigate possible collapse scenarios through nonlinear static analysis, performance point,
target displacement, and structure age calculation. This aspect has been treated to locate the
most fragile parts of the structure, in order to identify these areas which will be subject to
subsequent consolidations.
Phase 5 “Proposals on rehabilitation and retrofitting strategy and critical review of
restoration projects”. “On heritage buildings, any attempt for strengthening the system is
facing the possibility of damage to one of the values of the building. Therefore, a vigilant
agenda for proposing rehabilitation plans for historical buildings should be adopted.
Practically, this phase of the work should be based on the structural engineering visionary
expertise in devising retrofitting techniques with damage tolerance constraints. Earthquake
engineering knowledge is also required for evaluation the seismic hazard risk level for each
rehabilitation technique. This parameter can be, later, converted to the seismic life expectancy
of the structure. Another face of the problem is assessment of damage to the historical values
of the building, attributed to each rehabilitation technique. This requires, at first, calculation
of damage ratios in each historical aspects of the building. These ratios will be used in damage
estimation and, consequently, evaluation of contemporary historical value of the building” after
the structural retrofitting. This important phase is closely related to the process of reverse
project review, which is explained graphically in detail in (figure-2).

38
Identification and Assessment and Target points and
response need analysis phase outputs

Aims & Limitations


Simulations,
Research questions Structural Challenges
Objectives verifications &
Materials Architectural
Survey
* Literature review,
BIM modeling
* On-site research, Highlighting the
Analysis and
* The state of art, architectural
* Documentation heritage and simulations
* Digitalization historical values
Theoretical
interpretations and
recommendations
Experts coopertaion Basic concepts of
and Stakeholders restoration and Proposals on Seismic
conservation/ retrofit strategy &
principles Implementations

Awareness of cultural
heritage
Monitoring process and Review

Figure 1. Initial framework of the study, Research stages and Management (source: author)

Above (figure 1) is shown a very general overview of the methodology proposed at the
beginning of this study (specifically in the research proposal phase), where the work is based
on 3 general pillars. The first phase includes Identification and response need, with all the
processes mentioned above, such as literature review, on-site research, state of the art briefly,
project documentation and archival digitalization. This phase includes experts cooperation,
stakeholders and general awareness of cultural heritage. The second phase includes the whole
process of theoretical assessment, the state of art, the review of the regional, international
context, also reflections, theoretical interpretations and analysis. The third phase summarizes
the entire phase of 3d modeling, analysis, simulations, BIM[2] involvement, recommendations
and proposals on intervention strategies. Also this phase is indirectly related to critical reviews
on the given proposals, linking the proposals with a theoretical basis and controlling the
application of theoretical principles on the implementation projects. This phase is potentially
reversible at the starting point and is cyclically related to phase 2 of the diagram. So it is an
initial methodological diagram, which has laid out the theoretical basis of the research and is
then completed and specified in the main diagram, which is presented in (figure 2).

2
Building Information Modeling “b.i.m.” is the methodology of digital transformation in the architecture, civil
engineering, technology & overall construction industry.
39
40
Figure 2. Principal methodology and process applied for cultural heritage on this study, main inputs of
theoretical concepts used and literature, research strategy, application, long-term strategy and expected
outputs (source: author)

The methodology is presented on a cyclical basis with inputs and outputs (Figure 2). Basic inputs
and theoretical framework is static and should be applied rigorously, while for the announced
objectives and expectations of outputs is left free zone to interpret according to the specific case,
while in this methodological diagram are proposed recommendations for other future post-
research, to take this study to other dimensions. The initial idea for the creation of this matrix
methodology was taken from the Nieto’s study (Nieto-Julián, Lara, & Moyano, 2021), further
this idea has been developed and updated according to the research of this topic. This theoretical-
methodological diagram means that it acts as a basic method to control procedures, in which the
results obtained at an early stage are re-incorporated back into the proposed BIM system in order
to optimize the effectiveness of cultural heritage interventions.

Regarding this cyclical circulation diagram (Figure 2), the intended purposes, in addition to
those discussed above, is to generate a digital platform or adapt to current platforms that apply
BIM, which includes the database of cultural heritage objects in Albania in a digital information
model. This is the first research phase integrated from the theoretical work, using an existing
BIM structure. The system management in this study is focused on research, theoretical
interpretation, preservation, consolidation, restoration and awareness for heritage
dissemination; in addition, the proposed methodology is theoretically applied to 3 case studies
of cultural heritage or architecture in Tirana.

Figure 3. General diagram on the research method proposed in one of the cases selected for analysis of
this study. (source: author)

41
Consideration of engineering simulations, study of types and parameters of earthquakes that
may affect the performance of these objects, theoretical basis for the treatment and evaluation
of structural performance, inclusion of engineering database in architectural modeling files,
the connection of the theoretical basis of Eurocode as well as the comparison of engineering
parameters after almost 1 decade, are an important part of the methodology treated in this
study.
The methodology shown in these graphic diagrams aims to achieve the basic objectives
announced above, such as archival digitization, modeling, simulation and analysis. The
issuance of conclusions and proposals does not mean the closure of the research for the created
system, but leaving the free path for post-doctoral studies or other research on the creation of
the inclusion of these theoretical aspects specifically in current programs using BIM,
interaction of parametric analysis referring to the interventions in cultural heritage, the creation
of the virtual museum of these objects and many other aspects initiated in this study for the
specific Albanian context.

1.6 Expected results

Regarding the expected results, Seismic analysis, simulations and architectural survey of
selected buildings will be developed. In terms of engineering & seismic simulations a higher
level of performance is considered, beyond the current level of "live safety" for the design and
consolidation of structures. This means looking for a new level of performance for the detailed
seismic analysis of these buildings, researching between live safety field and structural stability
(near collapse) field. Also, we should base on the basic principle of restoration of buildings, "It
should not interfere in architectural details, in the facade motives, but only on the structure or
skeleton". Accurate and prudent implementation of this phase will be based on the application
of innovative methods and technology of buildings repair and modernization.

1.6.2 Stakeholders

Concerning stakeholders there are 3 main groups. The first group consists of field experts,
architects, engineers, archaeologists, restorers and historians. The second group includes
administrators and actual users of these buildings, which is the government with all its units.
Also this group includes landowners. And the last group includes residents of Tirana.

1.6.3 International interest in this research

The need for the existence of these assets of historic values is nowhere denied rather they are
worth preserving. So, referring to these great values, this study is an added value for all studies
in the Balkan region. These types of researches are full of values to the region, based on large
wealth with old historical heritage that need to be repaired and updated.

42
1.7 Reasons to make this study and select this topic

Thousands of tourists and citizens who visit every year the central axis of Tirana, have different
cultural backgrounds. They see buildings and works of architectural heritage, and often, unless
they are architects or engineers, they manage to penetrate the style, elegance and architecture of
these buildings. They have read about the city, the history, they go to visit it, they are in front
of this part of the city heritage. In the multitude of problems of the city today, government and
local policies, the transformation of the city into a metropolis, new constructions,
reconstructions and additions have made professionals in the fields of engineering and
architecture or others unable to penetrate, in true elegance and value of these objects, fail to
perceive how they were and in what forms the original objects were, or even the urban planning
of the surrounding area which has changed completely. They come out almost disappointed by
the visit to the city. A tour guide or an application is not enough to make understandable the
form that the architectural works of the city have had, mainly of the period 1920-1940.

In this way, almost all the architectural and historical value of the city is lost, and consequently
our culture and national heritage. One aspect that would help a lot in the accurate study of these
heritage objects, is their 3D-dimensional modeling digitally with engineering methods.
structural analysis looking also at theories of architectural restoration or digital, virtual
reconstruction.

Such cases are similar in the history of engineering but also of restoration architecture. 3D
dimensions of architectural works of historical heritage or of the cities themselves. But to
achieve such engineering models and architectural reconstructions requires a good historical
and typological study of the buildings and the city itself, research on materials, facades and
archival projects, the study of analogous cases and typologies in other countries, mainly Italy,
but also the Balkan context. Only after it becomes complete and based on factual material and
historical data, can we allow ourselves to reach formal deductions and engineering models for
the shape of the buildings and for their structural condition today.

The other reason is related to the necessity to study the architectural aspect of the buildings,
especially those that have been little studied, but keeping it related to the engineering context
and structural performance, emphasizing that in previous studies the structural issue has not
been addressed. these objects.

Thus, following this logical flow, we found the reason for an in-depth research and comparative
work to study some key typologies built in Tirana by Italian designers, and to theoretically
investigate the principles used in design and construction as well as the structural performance
of objects. selected. Through this study we want to show that the typological architectural study,
coupled with the engineering and seismic context should precede and become the basis for their
3d virtual modeling.

43
CHAPTER 2.
Research on Structural, Architectural and Urban typologies of the period
1920', Italian design models

44
2.1 General characteristics of unreinforced masonry buildings designed in the 1920s

The control of masonry buildings is of growing interest from the academic, professional and
industrial world for the following reasons related to their diffusion and their response to external
actions:

1) masonry constructions constitute a large part of the existing residential and historical-
monumental building heritage;
2) some types of walls (for example stone walls or buildings with insufficient box-like behavior)
have shown a high vulnerability to seismic actions;
3) some construction types (for example tower buildings) have shown a dangerous sensitivity
to environmental vibrations, in particular those induced by vehicular traffic;
4) the materials constituting the wall textures and horizontals have often undergone irreversible
alterations caused by the chemical-physical actions of the environment, made highly aggressive
by pollution.

The pathologies manifested in the structural behavior, in particular in buildings of a historical-


monumental nature, have on the one hand raised the question of safeguarding the heritage
through political choices that are sometimes difficult to implement (for example the limitation
of traffic in historic centers) and, on the other hand, given a considerable impulse to the research
of investigation methodologies and to the development of experimental techniques aimed at the
knowledge of the state of affairs that allows, as previously observed, to prepare the
implementation tools for the restoration and / or construction consolidation.

The behavior of a building both from a structural and conservation point of view (durability)
depends on two characteristics:

1) From the wall typology (Bufarini, D'Aria, & Giacchetti, 2009), with reference to which it is
possible to make the following classification:
• brick masonry,
• well-squared stone masonry with regular courses,
• partially worked stone masonry and fairly regular courses,
• listed masonry,
• non-squared stone masonry with irregular courses,
• sack masonry;

2) The type of construction of the structural complex (Bufarini, D'Aria, & Giacchetti, 2009),
with reference to which the following classification can be made:
• buildings entirely in masonry (with vaulted horizontals);
• buildings with continuous masonry walls and with wooden or iron floors;
• buildings with masonry walls and reinforced concrete floors and curbs;
• mixed structure buildings.

The setting up of the campaign of instrumental investigations aimed at diagnostic control is


conditioned by the location of the building in question within the above classes, which in turn
may require, in the preliminary phase, the use of special relief techniques. These techniques
must aim to highlight the aspects that have the greatest influence on the performance capacity.

45
For buildings built in seismic areas, or in any case subject to dynamic actions, the degree of
vulnerability depends on numerous factors (Bufarini, D'Aria, & Giacchetti, 2009):

• the shape in plan and the distribution of masses and stiffnesses in the height (structural
system);
• the type of construction of the structural elements and the type of assembly;
• the quality of the binders often altered by physical-chemical degradation phenomena;
• the degree of clamping between walls;
• the type of connection between walls and horizontals;
• the presence or absence of pushing elements;
• the stiffness of the floors in their own floor;
• the global and local dynamic characteristics, linked not only to the masses but also to
the overall rigidity and their relationship with the dynamic characteristics of external
actions;
• the state of tension and the current geometric configuration, due to the statically acting
loads.
• To these factors must be added those related to soil-structure interaction:
• lithology, hydrogeology, and geotechnical characteristics of the sediment soil;
• type of foundations and related tax rates.

To understand better the difficulties inherent in the diagnostic process oriented towards the
design of seismic improvement and / or adaptation interventions, a real case is illustrated having
as object of study a school building characterized by a great constructive complexity.

A wide campaign of endoscopic observations made it possible to find that the structure of the
main building is made up of masonry walls which, almost entirely, were built with a "sacco"
type[3].

In the walls of the first elevation (basement) the faces are sometimes both of solid brick with
one head but more frequently of limestone with regular ashlars. The stone blocks are of a pink
or white limestone nature with thicknesses ranging from 15 cm to 37 cm. In most of the cases
investigated in the same wall, the internal and external facing are made with stone blocks of
different colors. With regard to the masonry walls of the floors above ground, the facing are
both made of solid bricks and have an almost constant thickness equal to 13 cm. The filling
between the two linings of the “bag”, whether they are in stone blocks or in bricks, is always
made up of a sort of conglomerate of rounded aggregates of various sizes linked by a rather poor
quality cement-based mortar.

In only one case, at least among those investigated, the masonry is compact with two heads
made with bricks placed at the head.
Inside the type with double brick lining there is a sub-group of walls which also function as
infill, which have an external facing in red perforated brick and an internal facing sometimes of
solid bricks of yellow color, sometimes of square stone, sometimes of a mixture of stone and
brick.

3
“a sacco” masonry: with a thick inner wall and a thinner outer wall, where the gap was filled with stones and
mortar. In this masonry (the so-called “a sacco” typology) it is possible to recognize stones with different height-
length ratio of the external face (1:1; 1:1.5; 1:2).
46
In all cases the mortar joints are of variable thickness around 15 mm. The bedding mortar is
always cement-based, characterized by poor consistency and sometimes tending to pulverize.
To allow the creation of openings of considerable light, in some cases the internal walls have
been removed and replaced locally with architraves having considerable spans. The disposition
of the resistant walls is quite regular even if, especially the infill walls, they are characterized
by the presence of numerous openings.

The horizontal elements are made up of brick-concrete floors with parallel ribs placed at a
distance of 50 cm. The pitched roof is also made with the same type of floor. This floor rests on
walls which, for some sections, have been made with double-headed UNI type perforated bricks.
The building that have the big spaces with plan dimensions of approximately 27.54 x 13.10 m
and a height of approximately 6.00 m. The connection between this building body and the main
one takes place through a covered path made structurally independent by a technical but not
seismic joint. The load-bearing structure consists of a perimeter masonry on which a roofing
consisting of a brick-concrete floor is supported, carried not only by the transverse walls but
also by three spatial beams in reinforced concrete, also arranged in the transverse direction. The
connection between the beams and the underlying walls takes place by means of three pairs of
pillars always in reinforced concrete. which transmit the loads to a continuous curb made on the
top of the walls. The autopsy examination showed that all the main beams have, at the ends,
capillary cutting cracks and, across the mid-section, flexural cracks.

From the surveys carried out, it is immediately clear that the supporting structure of the building
has a multiplicity of structural types, however all attributable to that of “brick masonry with
independent facings and filling of poor consistency” (Bufarini, D'Aria, & Giacchetti, 2009). The
vestments were made with different techniques:

• solid brick masonry of predominantly yellow color and cement mortar;


• white limestone masonry with squared ashlars and cement mortar;
• pink limestone masonry with squared ashlars and cement mortar;
• mixed masonry of solid bricks and white or pink limestone with squared ashlars and
cement mortar;
• chaotic matrix masonry with sporadic presence of brick blocks;
• semi-solid red brick masonry and cement-based mortar.

The overall thickness of the masonry walls is also highly variable in relation to that of the filling;
in fact, the thickness of the vestments is always kept almost constant and equal to a head (about
13 cm). Since this type of investigation has been extended to a sufficiently large number of
masonry, it seemed legitimate to attribute the same type of sack masonry to the walls not directly
investigated.

Related to the building with big hall spaces, the masonry, have a thickness of about 44 cm clear
of the plaster, is made with a “sacco” typology in which the external facing, having a total
thickness of 26 cm, is made up of two linings 12 cm thick each, the first of semi-solid red bricks
"facing" and the other, simply placed next to the first through the interposition of a 2 cm thick
cement mortar plaster, made with solid bricks. The inner lining, on the other hand, is made up
of perforated brick blocks. Regarding to the connections between orthogonal wall walls, the
close visual examination showed that the clamping was carried out sporadically by crossing and
overlapping a very limited number of elements (bricks and / or stone blocks) to a depth of a few
47
centimeters. This generally results in an insufficient degree of mutual interlocking which makes
the clamping of modest effectiveness. A careful autopsy investigation revealed that, on the
contrary, the degree of connection between the masonry walls and the brick-concrete floors
appears to be effective.

The endoscopic survey was followed by other determinations in situ and in the laboratory. Tests
with a flat jack in a single configuration made it possible to evaluate the current state of tension
of the masonry linings. Having obtained these values, the application of the flat jacks in double
configuration allowed to determine the elastic parameters (Young's and Poisson's modulus) in
an interval around the value of the current working stresses (for gravitational loads only) and of
the tension in situation seismic. Finally, the on-site removal of sample bricks and mortar made
it possible to directly determine the resistance to compression of the elements making up the
masonry walls. All the information collected during the experimental investigation campaign,
suitably processed, made it possible to fine-tune the structural calculation model aimed at the
seismic verification in the current situation and, subsequently, to make design choices with the
aim of adequately increasing the security level of the building.

In fact, having recognized that the weak points of the main building were substantially the poor
effectiveness of the clamping between orthogonal wall walls and the sack type of the walls, it
seemed technically correct to improve the situation, in both cases, by means of post stretched
that could enhance or realize a structural solidarity.

The effect of the type of solidarity intervention on the walls was finally translated into an
appropriate structural model in order to calculate the increase in resistance obtained.

48
2.2 Italian concept, building design and planning strategies for the Albanian cities

Based on the research carried out in the Albanian technical archives, also on the literature of the
time and the current one, it can be said that the Italian designers contributed to the planning and
construction of Albanian cities according to two main phases, linked to the Italian conquests of
the country. The first phase, which runs from 1915 to 1939, brings the Italian architects and
engineers employed in the technical offices of the various cities. Their contribution in Albania
is extensive and ranges from design and construction implemention. of including aslo the
infrastructural system, the drafting of the first Regulatory Plans of Tirana and the arrangement
of city centers through the construction of representative buildings and architecture of great
public interest.

The second period begins with the creation of the "Central design office for Construction and
Urban Planning" for Albania, especially Tirana, from 1940 until 1943, at the time of capitulation
of Italy. The interventions that have taken place in recent years are all to be traced back to the
activity of this design-office which consisted in the control of public and private construction
activities in Albania, in the drafting of new building design "especially institutional buildings
of special importance but also villas or residences", city plans and urban planning regulations.
As well as in the strengthening and control of all cities infrastructural systems, related an
efficient development of the cities and territories adjacent to it. In addition, the work of this
design-office was of a great double value, on the one hand a centralized political instrument for
albanian territorial development while on the other hand it was a guarantor of design quality and
architecture.

The design activity concerned the following works: "valuable projects in Tirana, turning the
port of Durres into one of the largest in the region, port of Vlore and Porto Edda in Saranda at
south, Shengjin port, new projects and urban plan for Berat and Elbasan, the organization of the
central area of the Shkoder and Korça city. And finally the urban intervention of some small
towns with strategic importance such as Milot and Permet. The italian designers of the central
office in the preliminary phase of drafting the projects and plans followed a common practice
for all cities, considering the variables due to the different contexts at second period. The
project-startegy consisted of historical knowledge, the type of approach with the existing city
plan and its connection with the new expansion. The historical study was focused on the re-
evaluation of monumental cultural heritage and traditional characters, in particular for the
oriental and ottoman ones that gave the cities an aesthetic aspect. The enhancement of the
architectural and cultural heritage was the basis of the italian strategy.

The connection strategy between the new city and the existing one was subordinated not only
to the road system or infrastructure, but also to the green bands spaces and in particular to a
commercial or monumental directorate axis. In all coastal and portual cities, the policies already
in place in Italy since the 1920s were applied for the enhancement of seaside tourism. Through
promotions and financial incentives was promoted all types of accommodation services for an
attractive increase. It has been ascertained that the italian designers considered cities to be living
organisms, often resorting to the paradigm of the human body they were able to better manage
and plan their development. This design philosophy began to be further applied in building
complexes and villa projects which today are considered the basis of cultural heritage sites.

49
2.2.1 Tirana, the construction of a capital city. Birth and evolution of the Ottoman city

Based on the theoretical research, the Architect Marco Stigliano has summarized this article for
the design of the Albanian capital, Tirana, as follows:

The Ottoman conquest of Albania, which began in the 14th century, found in Tirana an
important crossroads between the main transport routes between East and West.

The transformation of Tirana from a village to a city dates back to the seventeenth century when
various religious buildings began to be built, as part of the desire to convert the population from
Christianity to Islam. An urban system with a "diffuse archipelago" was formed: a series of
distinct urban nuclei, which probably referred to powerful local families, organically organized
around the centrality of the mosque which became the element of social and political
aggregation of the population .

The first urban nucleus of Tirana probably grew around the old Pasha Sulejman mosque (1614),
at the center of the current conformation of the city, at the intersection of the main interregional
transit arteries. Along with the mosque, other buildings were erected, including those of the
feudal lords and their relatives, on the right bank of the river Lana. The second urban nucleus
was created in the early 18th century around the Fire Mosque about 600 meters north-west of
the first nucleus, where today Rruga Barrikadave intersects Rruga Fortuzi. The mosque was
called "Beshiri mosque" after its builder. The third nucleus was built north-east of the first and
the Zajmi mosque was erected there, at the intersection of Rruga Dibrès and Rruga Thanas Ziko.
The fourth nucleus dates back to the time of the foundation of the Haxhi Ethem mosque, about
200 meters west of the old mosque.

In other neighboring areas, around the first nucleus, other agglomerations were born, always
with a mosque as a fulcrum (Stèrmas 1840; Kokonozi and Bèrxolli in the 19th century; Karapici
1858; etc.). Each of these nuclei was born independently of the others, until, as they grew up,
they had merged to form a spontaneous urban design in patches of leopard. Added to this was
the feudal fragmentation of the land and the absence of a central administration.

The construction of the Sulejman Pasha mosque, the Baths, the Inn, the Oven and the Pasha
Kapllan Tomb, historically and architecturally symbolize the birth of the city of Tirana1. All
these buildings, except the last one, have been destroyed over time, especially during and after
World War II. The most historicized current pre-existing structures of the Ottoman period, the
Ethem Beu mosque and the Clock Tower, were built between 1794 and 1822.

The city in this period was recognizable in two distinct areas: a residential one, with low brick
houses, very extensive without apparent limits with the countryside; the other denser represented
by the bazaar, a real shopping center, destroyed and rebuilt several times. The latter insisted on
an area of about two hectares along the road to Dibrës at the intersection with the main
interregional roads; Demolished and rebuilt in 1905, it had the typical appearance of the
Ottoman market, the narrow and winding streets were defined by single-storey buildings
consisting of a shop and a back room with wooden roofs that protruded in a cantilevered way.
protect from bad weather. In 1960 the bazaar was definitively demolished to make way for the
Palace of Culture.

50
2.2.2 Identification and the performance of the cultural heritage in Tirana

Selected projects analyzed in this study, tackle the delicate problem of the transformation and
integration of modern buildings, a practice that is now widespread in the Albanian capital, but
perhaps not sufficiently debated: just think of the "style" extension of the Tirana town
Municipality in 2004 , to projects for the Parliament house, to the expansion and functional
adaptation of the Bank of Albania.

The buildings taken into consideration are the Placetenential Building, currently the ministerial
complex and for which the current Town urban Plan provides for an expansion, the former
Skanderbeg Circle, intended for demolition frequently, for which reuse is instead assumed as a
"museum of city "in analogy to the function of "City Palace "foreseen in 1943, and the Ex. Hotel
Dajti, whose possible adaptation (actually owned by the Bank of Albania), is verified while
maintaining its hotel destination, a function entered in the collective memory that has assumed
a value over time symbolic.

In these cases analyzed in this study, the extensions and additions are interpreted not as additions
to parts of buildings, but as stylobates, podiums, wings, excavations, which relate the existing
building to the open space and measure the surrounding void. The modeling and excavation of
the bases allows you to create open but delimited spaces, conquering a condition of interiority
and closure.

For example, in the project for the expansion of the Ex. Lieutenancy Building, a great emergence
stands out on an excavated stylobate ground. Thus we work on a double register: the small scale
of the city with enclosed spaces and the large scale of the new urban landscape, where the
isolated volumes and the great void are no longer deaf towards each other, but enter into mutual
tension. .
In their architectural definition these projects want to interpret and give shape to that double
soul of Albanian architecture that appears clearly in the construction of traditional houses, where
the use of the stone that roots the building on the ground and the use of wood coexist. or in any
case light systems, which delimit the places of living.

51
2.3 General characteristics of existing masonry and rc structures, period 1940 in general

Nowadays, thanks to the requirements for the construction of building interventions, action has
been taken almost everywhere on the durability of buildings; in fact almost all the buildings
have undergone ordinary and extraordinary maintenance. However, this does not give any
certainty in terms of the structural safety of the building itself; for this purpose much more in-
depth investigations are needed into any architectural, structural, executive and material
deficiencies.

The seismic behavior of the building is strongly conditioned by its regularity in plan and
elevation. Its structural performance, especially at the ultimate limit state, however, depends on
the strengths of the materials. It is therefore essential to have detailed information on the
reference values of these mechanical characteristics. It is quite clear that this information must
be sought on the individual building when it comes to assessing its vulnerability, however it is
useful to have a large-scale picture of the size of the phenomenon of distribution of resistance
on the building stock. Within the vast building stock, constructions with reinforced concrete
structures play a special role because the problems of durability, linked to the temporal response
of the materials, present themselves in a worrying way and their solution is generally technically
difficult and economically very expensive. It is known that the durability of the reinforced
concrete structure is linked to the quality of the concrete, ultimately to its resistance and to the
relationship between it and the working tension and to the level of protection that the cement
conglomerate is able to operate. on armor.

For this reason, it is very useful to understand, from a statistical point of view, what resistances
can be expected on a building based on the time of construction of the same. It is known that in
the case of normal distribution large errors have a small probability of occurring. The data
processing was therefore preceded by a filtering procedure according to the criteria of rejection
of the observations.

What has been observed in the generality of the most striking cases is that the serious
architectural deficiencies have been accommodated by the structural designers without being
put in place sufficient corrections to heal them or at least mitigate them. To these shortcomings
were added structural shortcomings resulting from the lack of reference regulations and glaring
shortcomings of an executive nature which are essentially due to:
• the mediocre mastery used for the construction of structural works and components defined
as “non-structural”, ie infill walls, partitions, cladding;
• the mediocre and sometimes bad quality of the materials used for the construction as a
whole;
• the lack of attention on the part of the construction management.

The main cause of the lesions on non-structural elements is to be found above all in the excessive
deformability of the structure due to which the interpy displacement limits are largely exceeded.
For a building to presumably respond correctly to an earthquake, it must be as simple,
symmetrical, hyperstatic and regular as possible both in plan and elevation.

It is evident that it is not possible for existing buildings, and in particular those prior to the entry
into force of the first seismic standard, to comply with the conditions of regularity; it is also true
that some conditions are essential for a correct and necessary seismic response.
52
In particular, the simplicity of the geometry in plan is an essential condition, therefore all
buildings that do not have this quality should be evaluated more carefully. It is also important
that there are no significant planimetric deviations between the position of the elements of
greater horizontal stiffness, such as structural or non-structural walls, stair groups, etc., and the
distribution of the masses of the building which, otherwise, would give result in dangerous
torsional effects.

The distribution of non-structural elements such as “non-cooperating” masonry infill panels also
affect the overall behavior of the structure in the event of an earthquake. In fact, even if they are
not considered in the calculation phase, the infill panels, until they collapse, contribute to the
rigidity of the building and, consequently, the irregularity of their distribution in elevation leads
to a concentration of efforts where these are less present and the formation of the so-called soft
plane as in the case of the pilotis and the case of the garages plane. For the purposes of a good
overall dissipative behavior, the inelastic deformations must be distributed in the largest possible
number of flexible elements, in particular in the beams, while avoiding their occurrence in the
less ductile elements, such as the columns, and in fragile resistant mechanisms. To obtain this
result it is necessary to pay attention to the irregularities of the local connections between the
structural elements such as wide beams on narrow column, misalignments of the beams with
respect to the columns, etc., and also check that the arrangement of the reinforcements in the
critical areas is correct, in particularly those near the connections between the structural
elements such as for example nodes between beams and columns, the grafting of the beams in
the stiffening walls, etc.

As with the geometric-architectural requirements, obviously, the regularity of the structural


elements also contributes significantly to the correct seismic response of a building. It is
therefore a good rule to have frames warped in the two main directions avoiding misalignments
of the beam-pillar joints and beam-beam couplings. The experience, which is acquired from the
direct observation of the damage produced by earthquakes, teaches us that the main structural
factors, responsible for the seismic damage of reinforced concrete constructions, concern both
the global behavior of the structures and some executive imperfections of a local. Statistical
studies carried out in various countries on buildings with evident structural deterioration have
shown that most of the damage occurs during the construction phase of the structures and is the
result of human errors. Only 29% of structural damage is considered inevitable. More in detail,
the results of these investigations can be summarized as follows:
• the damages are mainly produced in the execution phase;
• the human factor is largely responsible for one's own ignorance, neglect, underestimation of
the consequences, errors.

The conclusions that can be drawn are essentially the following:


• the bad positioning of the reinforcements, the incorrect use of diameters and the consequent
reduced thickness of the concrete cover is responsible for the cracking and subsequent fall
of pieces of concrete due to the thrust due to the expansion of rust (spalling);
• incorrect tying of the brackets causes slippage during casting;
• the indiscriminate execution of important structural variants without authorization involves
the upset of the static scheme;
• the impurities present in the badly washed aggregates are responsible for the reduced
strength of the concrete;

53
• early stripping, before the concrete has reached the necessary strength, is responsible for
injuries;
• the production of concrete on site, thus not resorting to the more controlled industrial one
and with a correct mix-design, involves the presence of different classes of concrete;
• the incorrect compaction of the concrete leads to the segregation of the various constituents
of the mixture and therefore to the creation of gravel nests;
• the addition of water in the concrete mixer at the time of casting creates an alteration of the
water-cement ratio and therefore a reduction in the necessary resistance.

In addition to these problems there are all those "small" interventions carried out by man after
the construction of the building, such as the execution of holes in load-bearing structures for the
passage of electric cables and / or hydraulic pipes and chamfer of the pillars to facilitate the
passage of vehicles in the local garages.

Until a few years ago it was believed that a reinforced concrete structure was practically
unalterable over time. Daily practice has shown that the reality is quite different as many
reinforced concrete structures of the past have shown signs of decay, the causes of which are:

• descaling: it is a phenomenon due to fresh or slightly acid rainwater and produces an increase
in porosity, creating more favorable conditions for the penetration of aggressive agents
inside the structure and a loss of compressive strength. The cement, in contact with rainwater
poor in salts, loses lime due to hydrolysis with a consequent increase in the size of the
capillaries. The loss of mechanical strength, a consequence of the increased porosity, leads
to a decrease in compressive strength around 1-2% for every 1% of the original content of
hydrolysis lime removed by washing. A particular cracking method is attributable to the
progressive decalcification: along the surfaces of reinforced structures, with wall
reinforcements exposed to alternating dry and wet cycles, cracks open parallel to the
direction of the reinforcements;

sulphate attack: the destructive action of the cement paste is determined by the
magnesium sulfate which, reacting with the calcium hydroxide present in the concrete,
gives the gypsum product. This reaction takes place with an increase in volume of
about 120%. The gypsum produced then reacts with the hydrated phases coming from
the hydration of the tricalcium aluminate, forming ettringite. The increase in volume
is approximately 370%. The sulphatic attack is manifested, therefore, through the
swelling of parts of the structure and consequently determine its weakening;

carbonation: carbonation is a neutralization process between the alkaline components


present in the outer layers of the concrete surface and the acidic substances coming
from the external environment. These acid substances are generally the carbon dioxide
CO2 contained in the air and in particular industrial atmospheres and the sulfur dioxide
SO3 contained in the rain. Certainly it is carbon dioxide that most determines the
process considering its high concentration in the air (600-1000mg/m3 of air). The
aforementioned chemical reaction involves lowering the pH from the initial value of
13-14 to pH values <9. In this acidic environment, the solubility of the calcium
carbonate present in the concrete increases both in the form of inert material and
through the transformation of Ca (OH)2. A chemical process is then triggered that leads
to the formation of calcium bicarbonate, soluble in water, therefore easily removable
54
by rain. The subsequent entry of water through the pores of the concrete therefore also
involves the corrosion process of the reinforcements;

corrosion of reinforcement: corrosion of reinforcement is certainly the most important


degradation process for the durability of a reinforced concrete structure. The corrosion
of the steel of the reinforcements occurs through the electrochemical process of redox.

• The anode and cathode are supplied by the same armature, in fact along the same bar the
areas coated with very adherent oxides (calamine) act as the cathode, the electrolytic
solution is formed by water absorbed by capillarity and a soluble salt. The process takes
place with constant subtraction of material from the anode and deposit of ferric hydrate
(rust). Since the rust occupies a larger volume than the original steel, there is therefore
cracking of the concrete and the exposure of new sections of reinforcement (spalling).
Corrosion can also be induced by the action of aggressive substances (chlorides) present in
the concrete as they are transported from the external environment. In the presence of water
and oxygen, these substances affect the protective oxides of the reinforcements, even in non-
carbonated concrete, (pitting), thus creating an anodic zone from where the electrochemical
corrosion process develops;

• the alkali-aggregate reaction: after hydration, Portland cement is characterized by a high


concentration of alkali (sodium and potassium salts) in the solution contained in the pores.

Currently, the alkali-aggregate reaction represents one of the most worrying forms of structural
degradation for a variety of reasons but above all for the fact that it is unstoppable if not by
avoiding the entry of water or water vapor into the pores. If some waterproofing or
dehumidification measures (for example by means of impregnation based on silanes and / or
siloxanes) can be carried out for elevated structures, the same measures are almost impossible
to carry out for foundation structures. Depending on the degree of reactivity of the silica, the
moisture content, the alkali content present in the cement and, finally, the environmental
temperature, the phenomenon can occur relatively quickly (a few months) or even after several
years.

55
CHAPTER 3.
Theory of Restoration and Architectural Interpretations

56
3.1 Theoretical summaries, elaborations and analysis on the principles of International
Charters for Conservation and Restoration

The need to protect architectural monuments from destruction and alteration found its first
interpreters "architects, engineers and other professionals" at the end of the eighteenth century,
leading personalities such as William Morris and John Ruskin had an enormous influence on
the theoretical elaboration of the discipline, but initially their voices remained highly isolated,
with no massive impact.

In 1883, an important congress held in Venice brought together architects and engineers around
a table to discuss restoration topics and find a point of mediation: after years of experimentation,
some principles were laid down which should essentially be guaranteed, along with
conservation. of monuments, even a correct reading of them.

The result was a complex and gradual elaboration of principles and recipes, later codified and
included in a series of documents aimed at guiding interventions according to basic principles
and postulates, so-called "the Restoration Charters". From the Athens Charter of 1931 to the
"Krakow Charter" of 2000, the texts are reported to be preceded by a brief introductory note.

3.1.1 International conference of Athens, the charter of Athens 1931’

The first charter of the cultural heritage restoration and conservation was written in 1931 by the
“International Conference of Architects” gathered in Athens, Greece. It is made up of 10 points
that more than establish real principles, called recommendations, addressed to the governments
of the States, summarized as follows:

• take care of their heritage and architectural protection;


• standardize legislation so that private interest does not prevail over public interest;
• to expand the study of art and architecture in order to teach and raise awareness of the
population with love and respect for their architectural heritage.

If we analyze in the technical aspect, the "Charter of Athens" defends a kind of philological
restoration, rejecting stylistic restoration, accepts “the use of modern materials for
consolidation, such as reinforced concrete”, accepts only "anastylosis"[4] in the case of
archaeological restoration. (Kadluczka & Cristinelli, 2015)

The Athens Conference, convinced that the preservation of the architectural and archaeological
heritage of the cities is of interest to all States, which are the guardians of civilization, hopes
that the States will mutually give a wider and concrete cooperation and contribution to favor the
preservation of architectural and history monuments;

The Conference considers it highly desirable that the institutions and qualified groups of
professionals, without prejudice to any international public law, be able to express their interest

4
In architecture and archeology, anastylosis is the restoration technique with which the original pieces of a
destroyed structure are put back together, element by element, in the same position, for example after a possible
collapse.
57
in the protection of the cultural heritage in which civilization has found its highest expression.
and who currently appear threatened. The conference intended the exposition (her general
principles “concerning the protection of cultural heritage) to avoid risks by establishing
permanent maintenance to ensure the conservation” of the buildings. In the event that a
restoration appears essential following degradation or destruction, it recommends respecting the
historical “and artistic work of the past, without proscribing it architectural style of any epoch.
Also, the conference recommends maintaining, whenever possible, the adaptation of heritage
buildings which ensures their vital continuity, provided, however, that the new destination is
such as to respect the historical and” artistic character.

The Athens conference intended the exposition of the legislations whose purpose in the different
nations is the protection of cultural heritage of historical, architectonic or scientific interest; and
it “unanimously approved the general tendency, which in this way preaches a collective right as
opposed to the private” interest.

The Athens charter emphasizes that the principles and techniques exhibited in particular
communications are inspired by a common tendency, that is: To restore in place the original
found elements (anastylosis); and new materials needed for this purpose must always be
distinguishable. On the other hand, when the conservation of ruins revealed in an excavation is
recognized as impossible, it will be advisable, rather than devoting them to destruction, to bury
them again, after having taken precise architectural surveys. It is clear that the excavation
technique and the conservation of the remains require close collaboration between the
archaeologist, the architect and the engineer.

Architects, also engineers have intended various principles relating “to the use of modern
materials for the consolidation of ancient buildings; and they approve the judicious use of all
the resources of modern technology and especially the use of reinforced concrete element.” The
conference also notes that in the conditions of new use of the monuments are increasingly
threatened by external agents; and, while not being able to formulate general rules that adapt to
the complexity of the specific cases.

The conference recommends respect, in the interventions of buildings, of the urban character
and physiognomy of the city, especially the area close to the cultural heritage, for which the
environment and the landscape should be the object of special care. The same respect should be
paid to some picturesque views. The object of study may also be plantations and plant ornaments
suitable for certain monuments to preserve the ancient character.

The Athens Conference, fully convinced that the best guarantee for the preservation of cultural
heritage and works of art comes from the love and respect of the people, and given that these
feelings can be greatly favored by the right actions in restoration.

3.1.2 Italian international charter for the conservation and restoration of monuments
1932'

In 1932, the High Council of Antiquities and Italian Fine Arts issued a "Restoration Charter",
which may be the first official directive of the Italian state for restoration. On the same principle
similar to the “Athens Charter”, but with some additions and more specifications by Gustavo
58
Giovannoni, such as "scientific restoration". Giovannoni (1873-1947), Italian architect and civil
engineer, was the first to suggest a methodology, in every aspect necessary to include all the
most modern technologies to achieve the achievement of scientific restoration.

The Superior Council of Antiquities and Fine Arts in Italy, bringing its study on the rules and
principles that should regulate, also improve the restoration of cultural heritage, which in Italy
rises to the rank of a primary national issue and coming from the need to maintain and improve
and more the indisputable primacy of restoration in this activity, consisting of science, art,
architecture, engineering and advanced technology. A brief summary of the principles of this
conference is summarized below:

• At the conference they were very convinced of the multiple and very serious
responsibility involved in any restoration projects, ensuring the sustainability of the
destroyed elements. Placing his hands on a complex of documents of history and art
translated in stone, no less precious than those preserved in museums and archives,
allowing numerous studies that may have brought unexpected new definitions in the
history of architecture;

• Considering that in the restoration projects various criteria of different order must be
united but not eliminated, even in part: that is, the historical reasons that do not want to
cancel any of the phases through which the architectural heritage was composed, nor
distorted its knowledge with additions that mislead scholars, nor disperse the material
that analytical research brings to light;

• The Italian Conference and its founders believed that after more than thirty years of work
on-site carried out entirely with great results and recommendations, a set of specific
lessons and principles should be drawn from these results to validate and clarify a theory
of restoration already established continuously in discussions of the Council and by most
of the superintendents for Medieval and Modern Art; So, according to this theory
controlled by practice, the essential principles will be given.

3.1.3 Analysis and notes on the context of the 1964 Venice Charter

World War II, considering the destruction of the European architectural heritage, brought to the
fore the problem of architectural restoration. At this particular moment, the practice of
restoration almost always extended, rebuilding what already existed, even at the risk of
committing historic forgeries.

After the post-war reconstruction phase, architectural culture again questioned the exact
restoration practices and at the Second International Congress of Monuments held in Venice
from 25 to 31 May 1964, Architects and Technicians, created a new card. Italian scholars such
as Roberto Pane, Pietro Gazzola and Cesare Brandi made a fundamental contribution to this
"Venice Charter".

The scientific material consists of 16 articles, which admirably summarize the principles that
can be considered immutable in the methodology of architectural restoration. This charter
emphasizes above all the importance of the historical aspect of a building and introduces for the
59
first time the concept of preservation of the urban environment that surrounds monumental
buildings. Below is a very concise summary of the basic principles of this conference:

• Architectural monuments should be considered part of a larger ensemble;


• Not only great works of art but also the most modest works of the past, which have
acquired cultural significance, are considered worthy of preservation;
• No new construction, demolition or modification that would alter the relationship of
mass and color will be allowed;
• Each architectural monument is inseparable from its place and the environment in which
it is located;
• All additions should be in contrast to the old one, be distinct from the old one and
possibly be removable;
• The valuable contributions of all periods in the construction of an architectural
monument must be respected, as the unity of style is not the goal of a restoration.

One of the most innovative aspects of the Venice conference was the specific point of view on
the building, not only the aspect of the historical monument will be treated as a separate case,
but the study will be extended, including the 'urban and landscape environment', which carries
as much historical and aesthetic value as the monument itself. The context, like the monument,
is an important evidence of a culture, of its development and of historical events that may have
occurred in time.

The charter is summarized in general definitions on the notion of the monument and its values,
and of the monumental complex as evidence of the culture of a civilization. Then it continues
with the treatment of various topics such as: purpose, conservation, restoration, monumental
complexes, archaeological excavations, documentation and publication.

Of more interest is the treatment of the issue of maintenance of works, in a regular and
continuous manner, avoiding or moving as far as possible the restoration interventions. Also
very important is the context of the new function that can be given to an object. The idea of a
function close to the authentic one is replaced with that of giving a use with a new function
which does not damage the values of the object, both during the adaptation phase and during its
perforation.

Given the recommendations of the Venice Charter and driven by the challenges that arise today,
we are aware that we are living in a period in which identities are characterized and become
increasingly distinct. Europe and the Balkans of the moment are characterized by cultural
diversity and consequently by the plurality of fundamental values in relation to dynamic,
immovable and intellectual heritage, by the various meanings associated with it and
consequently by conflicts of interest.

This requires all experts responsible for the preservation of cultural heritage to be increasingly
sensitive to the problems and choices they have to face in order to pursue the objectives set out.
Each community, through its collective memory, history and awareness of its past, is responsible
for identifying and managing its architectural heritage. This cannot be defined or solved in a
fixed way, with a formula. Only the way and methodology can be determined how the heritage

60
and its values can be identified, also the previous studies can be advanced and some of the gaps
can be filled. Creating matrices where it is attempted to provide ways for the most optimal and
efficient solution of these problems. Plurality in today's society also implies a great diversity of
the architectural and technical concept of cultural heritage as conceived by the entire expert
community and beyond. Architectural works, as the only tangible elements of heritage, are
carriers of values and wealth that can change perspective over time. This variability of values
that can be evidenced in architectural monuments is, from time to time, the complicated
specificity of heritage in different moments of the history of our cities.

3.2 The concept of restoration according to Cesare Brandi

In general, “any intervention aiming at restoring the efficiency of a product of human effort is
considered to be a restoration intervention. Therefore, there will be two types of restoration: one
for industrial artefacts and another for works of art; however, while the former will come to be
seen as a synonym for compensation or restoring the object to its original state, the latter will
be distinguished qualitatively from the former in that the former will consist in the re-
establishing of the product's functionality, whereas the latter, while such a re-establishing may
be relevant in certain cases” such as architecture, will be distinguished qualitatively from the
former. (Brandi C. , 2005)

However, the unique “product of human activity known as a work of art is described in this way
due to the fact that it is recognized in the consciousness for the first time, and it is only after this
recognition that it can be considered to be distinct from other products. This is a characteristic
that is unique to a work of art in that one does not inquire into its essence, but rather it becomes
a part of the world of life and thus enters the realm of individual experience rather than
remaining” isolated. It follows from this premise that any behavior toward a work of art,
including restoration intervention, is contingent on whether or not the work of art has been
recognized as a work of art in the first place. So, “the quality and modality of the restoration
intervention will also be closely linked to the recognition, and even the restoration phase, which
a work of art may have in common with other products of human activity, will be considered
merely an add-on phase in terms of the qualification that the intervention receives as a result of
the fact that it is carried out” on a work of art. “From this point on, there is the opportunity to
exclude restoration, as restoration of a work of art, from the common exception of restoration,
and to articulate its concept not on the basis of the practical procedures in which it is carried
out, but in relation to the work of art as such from which it receives its qualification, rather than
on the basis of the practical procedures” in which it is carried out. (Brandi C. , 2005)

Nonetheless, even though it is distinct from all other products of human activity, a work of art
always retains the characteristic of being a product of human activity when compared to things
of nature. It also poses two instances “as a work of art and a product: the aesthetic instance,
which is comprised of the fundamental fact of artistry for which the oeuvre is a work of art; and
the historical instance, which reflects the emergence of the work as a human product at a specific
time and location. Furthermore, the fact that it is presented to the recognition of a consciousness
at a specific time and in a specific location lends the work of art a second historicity that is
gradually transferred over time. It is at this point that the definition of restoration, specifically
the restoration of a work of art, can be stated in the following” terms: Restorative work is the

61
methodological moment at which the work of art is recognized in its physical consistence, as
well as in its twofold historical-aesthetic polarity, with the goal of transmitting it to posterity.
(Brandi C. , 2005)

This “definition shows that the imperative of restoration, like the general imperative of
conservation (which, despite its name, presents itself as a preventive restoration), is primarily
concerned with the material consistence in which the image manifests itself, rather than the
image itself. Afterwards, the first and most fundamental axiom is presented: one can only restore
the physical matter of a work of art. In contrast, the physical mechanisms that allow for image
transmission are not in opposition to one another; rather, they are coextensive with one another:
one does not have matter on one side and image on the other in order to transmit an image.
While this coextensiveness may be a necessary part of the image, this coextensiveness cannot
assert itself as being wholly intrinsic to the image. For example, the foundations of an
architectural structure, or the board, canvas, or wall that serves as a support for a painting, are
all examples of physical means” that can be used as supports.

The intervention “must be carried out in accordance with the requirements of the aesthetic
instance if the conditions of the work of art reveal themselves to require, for its preservation,
the sacrifice or replacement of a certain portion of the physical means with which it was
extrinsicated. The historicity of the oeuvre, on the other hand, should not be underestimated;
and this should be taken into consideration not only at the first historicity, which is that which
was founded in the act of formulating the oeuvre, but also at the second historicity, which begins
immediately after the act of formulating the oeuvre and extends all the way up to the moment
and location at which the recognition occurs in the consciousness” of the audience.

As a result, the dialectical “nature of restoration, namely as the methodological moment of


recognition of a work of art as such, results in the second restoration principle: restoration must
aim to re-establish the potential unity of a work of art, to the extent that this is possible without
creating an artistic or historical counterfeit and without erasing all trace of the work of art's
passage” through time.

By reading and browsing the theories of C. Brandi we can underline what he defines for
restoration: "Restoration is the methodological moment of evaluation of the work of art in its
physical content and in its dual polarity, aesthetic and historical, in order to convey its towards
the future ". So he emphasizes the evaluation of the tangible visual appearance, as well as the
temporal context, the extent of the architectural work in time with several stages.

From a careful reading of Brand's theories it is noted that there are limitations, his principles
cannot be applied to any kind of architectural heritage property. His “definition of restoration
as the methodological moment of recognition of a work of art” limits the field of study only to
well-known works of art or architecture, leaving aside industrial products that are meant as
services to cities. Restoration is thus an act of distinction - once the architectural or artistic value
of the building is recognized, and at this point conservation becomes a cultural necessity.
(Brandi C. , 2005)

62
3.2.1 Restoration principles and Terminology defined

Previous researchers' “definitions of the concepts of conservation, restoration, preservation, and


adaptation are summarized” in the following section, along with terms and definitions.

Adaptation – “A building's function, performance, and capacity are altered as a result of work
performed on it (over and beyond maintenance). Adapting a space to accommodate a proposed
compatible use. Modification is acceptable only when the adaptation has a minor impact on the
cultural significance of a location, and adaptation should include the smallest amount of change
to a significant fabric, which can only be achieved after considering all of the alternatives.
Adaptation refers to making minor changes that are still reversible, as opposed to making
significant changes that are less reversible” . Adaptation is the process of transforming a
building for a new purpose, and it may be the most effective method of preserving a historic
structure. (Aplin, 2002)

Conservation - There are a lot of things that need to be done to keep a place culturally important.
Maintenance: May include preservation, restoration, reconstruction, and adaptation, depending
on the situation. Most of the time, it will be a combination of more than one of these. It's
important to look after the natural and cultural significance of a place so that it doesn't lose that
significance. This definition is summarized according to the concept of Alpin. (Aplin, 2002)

Preservation - Keep the structure of a building the same way it is now by slowing down the rate
at which it breaks down. “Slowing down the deterioration of an old building by using the right
repairing” methods. Preservation is "the act or process of taking steps to keep the existing shape,
integrity, and materials of a historic property the same as they are now." Because some parts of
the building are old and important, they should be kept in good condition even if they are
damaged. Making sure that there isn't a lot of natural decay Preservation is similar to
maintenance, but it requires a lot more work and programs to keep the fabric of the building in
good condition and to protect it from damage. (Aplin, 2002)

Restoration - Back to how it was before: Getting rid of things that didn't belong there and
replacing them with things that did, without adding any new materials. “Returning the current
structure of a building to what it was like in the past without using new materials” . Restoration
involves “reinstating the physical and/or decorative condition of an old building to that of a
particular date or event”. The process of getting the building back to how it was before. It is
done this way so that original materials and techniques can be used, as well. (Brooker & Stone,
2004)

In the course of their lives, almost all heritage buildings will have these applications. In order
to keep a building and its values for present and future generations and make it usable at the
same time, all of these activities are done on heritage buildings.

3.2.2 Genesis of Cultural Heritage

The term "heritage", which comes from legal terminology, refers to anything “that can be passed
down from one generation to the next and the next and to the descendants” of the original owners.
This is one of the reasons that landscapes, buildings, and objects play a big role in the practical
63
management of heritage, because these are things that the law recognizes as property and can
be passed down through the generations. As a result, the term also implies that those who came
before and those who come after have a strong connection. This means that they have a sense
of responsibility and "trust." It's also true that law only exists as a mix of customs and judgments
dating back to the beginning of legal memory in 1086. This means that law itself, like the
heritage it describes, is based on what the ancestors did. (Avrami, Mason, & De La Torre, 2000)

Cultural heritage in general is a way to think about heritage that goes beyond the simple idea of
it. Ideological elements, like physical ones, help inheritors get into their rightful places and be
their true selves. In this case, inheritance is broadened to include these elements. An untrue
dichotomy is one that separates ideologies, ideas and feelings from property in the legal sense
of things like material goods and real estate. This is a wrong cut, though. People can't have social
ideas without things like land, objects, food and bodies used for them, as well as places where
they can show them off. No physical thing can be without its ideological information. This
physicality is why cultural heritage needs a lot of people to run and maintain it, why it can be
owned, and why no group can afford to keep all of its heritage in the way that it would like.

This analysis leads to the next important thing to talk about. Cultural heritage is thought of as
an outside expression of who you are, and it works in a variety of ways and at different levels.
It's a social fact, and like all social facts, it is both passive and active at the same time. It is
passive because it is a place where things are chosen. Most things, no matter what kind, don't
make it into the heritage zone. Its power comes from the fact that once certain elements are
passed down, they have power. They have a life of their own that affects people's minds and, in
turn, their choices. Heritage is a way for people to express their beliefs about themselves and
their communities. These beliefs nest with other beliefs about self and community to make a
whole that runs through all the ways politics, economics, and the use of resources affect us as
individuals.

Heritage is the cultural authority of the past, as well as a way for people and businesses to show
who they are. European modernism also has a lot to do with how people think and act. Heritage
(in the sense being talked about here) is also a part of that. There were a lot of changes in the
way people thought about things in Europe, especially in northwestern Europe between 1500
and 1750. This is about how people thought about things like history, the power of scientific
reason, the rights of the individual, and how the law worked. Modernism and heritage both have
their dark sides. When we choose and cultivate our heritage, we make distinctions between "us"
and "them," and we can expect all the nationalistic and fascist horrors that can come from that.
Like many modern ideas, the idea of heritage has spread around the world. We must keep in
mind that these ideas are not native to most cultures and are not by any means the only or best
way to build a relationship of identity on the cusp between the past and the present. (Avrami,
Mason, & De La Torre, 2000)

3.3 Interpretations on Cesare Brandi theories, also on “Time concept”, regarding the
architectural heritage and restoration

By reading and browsing the theories of C. Brandi we can underline what he defines for
restoration: "Restoration is the methodological moment of evaluation of the work of art in its
physical content and in its dual polarity, aesthetic and historical, in order to convey its towards
64
the future". So he emphasizes the evaluation of the visual appearance, which is tangible (in the
case of buildings we can relate the Brandi’s concept to the importance of the cultural heritage
facades.), as well as the temporal context, the extent of the architectural work in time with
several stages.

From a careful reading of Brand's theories it is noted that there are limitations, his principles
cannot be applied to any kind of architectural heritage property. His definition of restoration as
the methodological moment of recognition of a work of art limits the field of study only to well-
known works of art or architecture, leaving aside industrial products that are meant as services
to cities. Restoration is thus an act of distinction - once the architectural or artistic value of the
building is recognized, and at this point conservation becomes a cultural necessity.

Reflecting on the theories of Cesare Brandi, to make some interpretations some paragraphs are
detached as follows:

"Many lamentable and destructive errors have come about because of failures to
investigate the material constituents of works of art for both appearance and structure.
For example, there is a common misapprehension that unquarried marble is no different
than marble that has been worked into a statue. (This could be called the ‘illusion of
immanence’). Whereas unquarried marble has only its physical makeup, the marble in
a statue has undergone radical transformation to become the vehicle of an image. In
doing so it has become a part of history thanks to the work of human hands. As a result,
a chasm has opened up between its existence as calcium carbonate and its existence as
an image. As an image, the marble of the statue has separated into appearance and
structure, making structure subordinate to appearance". (Brandi C. , 2005, p. 52)

Considering this, it has become part of history thanks to the work of human hands of creators
or designers. As an image, the marble of the statue is divided into aesthetic appearance and
structure, making the structure dependent on appearance.

According to Brandi theories, the creation of the work of art, in other words the process of
design and creation was closely related to the artistic process, but also technical at the same
time. From this logic derive the basic principles of restoration, the almost sacred respect for the
original design, the authenticity, and the "raw material" considered as something irreplaceable
for any kind of project. This concept brings visual and tangible recognition by all, of the
conception of interventions and its repetition.

Another paragraph related more specifically with some kind of interventions on the work of art,
is taken from Brand's book on the theory of restoration:

“Reconstruction, re-creation or replication have nothing to do with restoration proper.


By their very nature, they go too far, and have legitimacy (if at all), only in the field of
deliberate reproduction of the processes used in forming a work of art”. (Brandi C. ,
2005)

“Nonetheless, it should be pointed out that even the worst reconstruction does, in fact,
document human activity, albeit mistakenly, and that it is still part of human history.
Therefore, it should not be removed - at the most it may be isolated. This position would
65
seem unassailable historically, were it not for the fact that it leads to a conviction of
non-authenticity or falsification for the entire work of art”. (Brandi C. , 2005)

According to Cesare Brandi, the basic concepts of a good restoration have nothing to do with
ordinary reconstruction or re-creation processes. But we can say that these processes can
manage to document valuable objects, in their own way they manage to create a story or revive
the history of the work of art. If through these processes the designer manages to create tangible
moments and make the object part of human history, we can say that in some way he has
succeeded, even though new debates open on historical forgeries and anti-authenticity.

Time concept according to Brandi’s theories meets in the architectural heritage in three different
moments:

1) The time of the realization of the work or project;


2) The time that passes between the end of the creation of the work and the moment in which
our conscience recognizes the work of art as such (present);
3) The time of recognition by the conscience;

In which of the three times will the restoration work be legitimate? In the first? No because it
would interfere with the creative moment (fantasy restoration), In the second? No, because it
would tend to cancel the changes that occurred at that time in the idea of restoring the original
state of the work (restoration restoration). In the third? Yes, because only in this way will he
respect the time that has passed without trying to eliminate its traces.

“Any behavior towards the work of art, including the intervention of restoration,
depends on whether or not the recognition of the work of art as a work of art occurs.
Therefore, also the quality and modality of the restoration intervention will be closely
linked with this recognition, and even the restoration phase, which eventually the work
of art may have in common with other products of human activity”. (Brandi C. , 2005,
p. 48)

Brandi's “theoretical work progresses through a clear distinction between the aesthetic image
and reality, a subject that was previously addressed by the Italian philosopher Benedetto Croce
and taken up by Brandi in his growth of his theoretical work. Art historian Brandi was the one
who first developed a theory of artistic creation, which he divided into two phases: the
construction of the object created by the artist, to which he assigned symbolic values that
distinguished it from what it was originally (its raw material), and second, the formulation of
the image, which is the process by which a reality is created. He called this pure reality because
it is distinct from the real world that surrounds us, or, to put it another way, it is an enhanced
version of the real world.” (Morera, 2019)

Regarding this distinction “between the two periods of creative creation, we can clearly
distinguish the notions of flagranza and astanza that are associated with the work of art in
connection to this distinction. The first of them, flagranza, relates to the existential condition of
art, specifically the consciousness of its bodily presence at the time it is observed by the
observer. In the realm of restoration theory, it is associated with the theme of the composition
of the work of art that is being restored.” (Morera, 2019)
66
3.3.1 Restoration according to the historical instance

Each architectural heritage has its own historical value as a human product made in a certain
time and in a certain place. With this in mind, the problem of conservation or removal of
additions and renovations arises in the restoration. Two definitions are elaborated below:
Addition: a new testimony of human doing and therefore of history;
Refurbishment: intervention that intends to reshape the work, get in the way in the creative
process to recast the old with the new.

For the historical instance, the preservation of only the addition is legitimate because the
reconstruction that aims to create a false historical is not acceptable and therefore must be
removed NB only when the reconstruction does not try to recast the old with the new and is
therefore recognizable, it must be preserved in its historical value.

3.3.2 The restoration according to the aesthetic requirement

Each work of art has its own aesthetic value as an artistic product. Additions or remakes. What
to do? Keep or remove? If the addition disfigures, distorts, obscures, partially removes the work
of art from view, it must be removed by documenting the removal. Conflict of interest between
the historical and the aesthetic instances: the aesthetic demand prevails since the essence of the
work of art is its being such, its artistry, only later its being a historical testimony.

3.3.3 The space of the work of art

What is the space that must be protected from the restoration? The work of art has its own
spatiality that fits into the space in which we live (the physical space of existence). The
restoration must ensure that the work of art retains its spatiality Eg: respect the spatial conditions
of an architecture or the possibility of perceiving an all-round sculpture from all sides

3.3.4 Preventive restoration

It means anything that aims to prevent the need for restoration. It is the first imperative of
conservation and branches out into several investigation directions:
First directive: determine the conditions necessary for enjoyment of the work both as an image
and as a historical monument;
Second directive: investigate the state of consistency of the matter;
Third directive: investigate environmental conditions, such as elements that can allow, threaten
or make conservation precarious. As in actual restoration, advances in science are important in
preventive restoration;

3.3.5 Theoretical analysis on the basic principles of restoration of the work of art

A creative process is completed when a piece of art is created and becomes a visible presence
in the world as a result of the work's presence in human awareness. Restoration can then be
67
considered, but it must always be done with the understanding that the artifact is a work of art,
that is, that it is a unique product of human activity, as the foundation for any work done on it.
This recognition will be critical in the rehabilitation process. “From his first definition of
restoration, published in 1948, Brandi distinguishes between two schools of thought: one is
concerned with restoring efficiency to the common products of human activity, while the other
is concerned with the actual restoration of special products, such as artistic objects. According
to this definition, a piece of art may only be restored on the basis of the aesthetic approach taken
to the work itself, which is not a matter of personal preference but is tied to the specificity of
the art form in question. It is the piece of art that dictates the terms of the restoration, not the
other way” around.

As Brandi describes in his book Le due vies, the process of recognizing a work of art /
architecture is comprised of the identification of the work as such by the observer (Brandi, 1966;
Brandi, 1989). Instead of examining the piece of art from the perspective of the artist / architect
or the observer, Brandi offers to study it from the following perspective:

• in and of itself, in its structure;


• when it is accepted into consciousness.

By considering “the case of a historical structure, it is possible to see how it is not only made up
of a particular amount of material, but also how each piece and the same spatial structural system
are conditioned by an architectural concept. Thus, the structure in its material form symbolizes
a physical phenomenon, but at the same time, the material serves the purpose of communicating
the architectural concept to those who are looking at the building. As a result, the structure as a
work of art is more than a physical occurrence; it also contains the aesthetic notion, which is
immaterial (phenomenon which is not a phenomenon). The building's material matures with
time, but it is only in the present that the aesthetic concept of the structure is understood by
human mind. As a result, Brandi concludes, a piece of art exists” in the present at all times. As
a result, every time the job is planned, even in the case of its restoration, it is necessary to
develop recognition on the part of the individual.

When considered in its entirety, a piece of art is more than the sum of its parts; all of the aspects
work together to create the 'unity of the whole' according to the artist's or architect's concept and
the unique way in which it was made. The tesserae of a mosaic are not art in and of themselves,
nor is the ad hoc collection of such tesserae. Additionally, a work of art or architecture can only
be 'what appears'; we cannot use an external model to reconstruct it into an ideal aesthetic
scheme, as was frequently done in the eighteenth century. Rather than that, the whole reveals
itself as an indivisible oneness that can theoretically continue to exist in its fragments even if
the original is destroyed to ruins. Restorative work must be limited to the original unit and must
be guided by the potential unity of the work of art, taking historical and aesthetic considerations
into account.

The work of art has a dual polarity, consisting of two aesthetic and historical requirements or
'instances' that combine to produce a whole with the possibility for unity. Its historicity is
inextricably linked to aesthetic values and their evolution over time. Both of these scenarios
must be taken into account when determining whether to restore. This principle is summarized
in a definition of fundamental restoration, which is followed by two complementing principles:

68
• Restoration constitutes the “methodological moment of recognition of the work of art,
in its physical consistency and in its double aesthetic and historical polarity, in view of
its transmission to the future”

• Only “the material of the work of art is restored”

• The “restoration must aim at re-establishing the potential unity of the work of art, as long
as this is possible without committing an artistic or historical forgery, and without
erasing all traces of the passage of the work of art” over time.

From “the definition of a work of art, it appears that time and space constitute the formal
conditions” and "find themselves closely fused in the rhythm that establishes the form".
Furthermore, time represents the phenomenological aspect in the work of art, divided into three
specific phases that form its historical time:

• the “duration of expression of the work of art while it’s being formulated” by the artist;

• the interval between the end of the creative process and the moment in which our
conscience actualizes the work of art in itself;

• the moment of “electrocution of the work of art in the consciousness of the present”.

Historically, a piece of art can be historicized at two distinct points in time: when it is
concretized “by the artist (for example, a palace erected in the sixteenth century) and when it is
recognized by the conscience of an individual in the present. It is possible to find examples of
the 'historical instance' in connection with various restoration instances of works of art. Even in
the most extreme situation of a ruin that is no longer recognizable as a monument to human
activity, restoration can be viewed as a process of consolidation and preservation of the current
state of affairs. When a piece of art ceases to be a work of art and becomes a ruin, it can be
difficult to determine when this has occurred. The only method to determine this is to determine
whether or not the object has retained its potential oneness (for example, the medieval structures
of S. Chiara in Naples). As a result, one should avoid attempting to restore the potential unity
of the work to such an extent that it destroys its authenticity and so imposes a new, historically
untrue reality that is superior to the ancient work in absolute” terms.

The task of art history, “according to Brandi, is to investigate - in temporal succession - the
'extra-temporal' moment, the internal dimension of time and rhythm; this is not to be confused
with the history of 'time in time' relating to changes in taste and” fashion, which "gathers in its
flow the finished and unchanging work of art." Restoration is “acceptable when it intervenes in
the third phase, which covers both the present and the past, because one should not expect to be
able to change the course of time or eliminate history. Additionally, the restoration must be
characterized as a historical event, as a human action; it is an integral component of the process
of passing the work of art into the future. Any other time for the restoration will result in arbitrary
results because of the nature of the restoration. In the United States, for example, identifying the
restoration with the moment of artistic creation will result in an imaginative restoration, which
will be at odds with the concept of a work of art as a completed” process. Stylistic or period
restoration, as they are defined in the United States, will also result in an imaginative restoration.

69
Another “pertinent subject is the work of art's interior spatiality in relation to the space
represented by its physical surroundings. The architectural spatiality of a structure is not
confined solely within its walls, but also in its relationship to the spatiality of the surrounding
built environment. There are particular difficulties in historic districts, when alterations to the
urban fabric alter the spatial conditions of certain historical monuments. The same issue applies
to architectural remnants. Ruins are frequently interwoven into the environment, as in the
example of English parks with medieval abbey ruins, and should be managed suitably in
connection to this new artistic” ensemble.

The “demands of the twofold polarity, aesthetic and historical, should not be reconciled through
a compromise, but rather through an adaptation inherent in the work of art itself whenever they
appear to be at odds with one another. When you consider that the uniqueness of a work of art
lies in the fact that it is a piece of art, the historical instance can be viewed as secondary in most
cases. An aesthetic instance can justify the removal of modifications that obfuscate or upset the
artistic picture of an object that has kept its potential unity while taking the precautionary
measure of documenting the fact that they have been removed. In contrast, if these modifications
have become iconographically cemented, their removal could result in the reconstruction of the
object from the ground up, which is not the intended outcome of the restoration process. Because
of this, anytime repressions are considered, the decision must be made on the basis of ideals that
take both the aesthetic and historical contexts” into account.

For his part, Brandi condemned a specific type of 'archaeological restoration' activity, in which
the ruins were frequently treated solely from the standpoint of history. It is sometimes the case
that even the ruins are the remains of works of art, and as such they must be submitted to the
same type of critical examination. Alternatively, the ruins could be a component of another work
of art; in this case, the unity of the second creation should be honored in the appropriate manner.
For example, the rebuilding of a medieval mullioned window in a classical facade (a tendency
that may be found in many European countries) can be difficult to justify on financial grounds.

Brandi asserted that the material, in connection to the aesthetic element of a work of art, can be
defined in terms of two functions: one dealing to the 'structure' of the object, and the other
relating to the 'appearance' of the object. Taking into consideration the artistic significance of
these artefacts, emphasis will generally be given to those that are the most artistically significant.
If a consolidation or reinforcing intervention is required for structural reasons, it must be
restricted to the portion of the material that is used to construct the structure and not interfere
with the look of the building. When restoring a historic structure, for example, the goal is to
keep the building's architectural appearance intact as much as possible. Brandi's difference, on
the other hand, should not be interpreted as implying that structure is of little significance; in
particular, when it comes to ancient architecture, the original structural system must be viewed
as a vital aspect for the entire meaning of the building itself. When it comes to archaeological
significance, the structure can be even more important than its appearance in some
circumstances, as it frequently holds vital archaeological information. The preservation of
historic buildings is not solely concerned with the preservation of their facades, as many believe.

If you are analyzing the aesthetics of a piece of art, a historic building, or even an ancient
monument that is partly in ruins, you can refer to the experience that Gestalt-Psychology, or the
psychology of form, has collected in evaluating the weight. A visual representation of the
various sorts of integration in relation to the existing original surfaces; fresh, hard, and showy
70
additions can quickly draw the viewer's attention away from the old patinated originals. The
repair will be necessary to accommodate the current reintegration into the historic structure and
not the other way around. This is because the restoration's goal is to maintain rather than
renovate a historical structure. Several approaches for the practical application of the theory to
the restoration of paintings were established under Brandi's supervision, including precise
criteria for the reintegration of gaps. Paul Philippot has investigated the extension of these
criteria to ancient buildings and structures in ruins in his books and ICCROM talks (Philippot,
1976). Brandi established three guiding principles (Brandi, 1963: 45):

• integration must always be easily recognizable upon close inspection, even if from a
distance it must not disturb the unity that is intended to be re-established;

• the material of which the image results is irreplaceable only where it constitutes the
appearance and not the structure;

• the restorations must not prevent future interventions for the conservation of the work
of art, but rather facilitate them.

In reference to previous restorations, Brandi mentions Hadrian's renovation of the Pantheon as


an example of re-establishing the monument's concept, not of restoration. The principles
underlying the Renaissance's 'restoration' of ancient statues “(Apollo of the Belvedere, Laocoon)
were fundamentally based on the concept of beauty, in accordance with Platonic philosophy;
restorers spiritually connected the statues to their own time, 'in a historical presence,' as if
translated into a new language. This is Brandi's reading of the Renaissance, not as a revival of
antiquity, but as a new style that incorporates components and notions from the past into a new
creative framework. Thorwaldsen, on the other hand, regarded classical antiquity as perfect and
remote, and his completion of the Aegina sculptures' arms and legs was based on an incorrect
interpretation of defined canons; he thus reproduced the missing parts using the artificial
language of nineteenth-century neoclassicism. According to Brandi, nineteenth-century revivals
aimed mostly at copying existing patterns rather than developing” a new architectural
vocabulary.

However, from a historical perspective, the additions can be viewed as the beginning of a new
era in history, which, in the case of architecture, can be linked to the development and
introduction of new functions. It is possible to justify the additions this manner, and the additions
must, in principle, be retained. As a general rule, it is vital to “appreciate the new unity that has
been produced by creative interventions, particularly if it reflects a historical phase. Any
removal must be justified, and a trace must be left on the monument itself; otherwise, the
demolition might easily result in the distortion of history and the annihilation of the past itself.
Constructions, on the other hand, have a different situation when they are designed to interfere
with the creative process and eliminate the time lapse between the moment of creation and the
moment of restoration. Brandi was opposed to the reconstruction of the bell tower of San Marco,
believing that in this particular circumstance only a vertical element, rather than a complete
reconstruction, was” required.

The use of “copies, replicas, or reproductions” can be accepted for documentation purposes, and
they are considered permissible only if the process does not cause damage to the original
building, as is the case when casts are used. In spite of the fact that copies and counterfeits are
71
created “using similar methods, counterfeits are distinguished by the intent to deceive; this can
be accomplished either by pretending to pass a replica as the original or by producing an object
in the style of a bygone period and offering it to the market as an original of that period (Brandi,
1992: 368; and Jones, 1990). A badly designed restoration might distort the creative concept of
a work by misinterpreting its proportions, surface treatments, or materials, a problem that is
particularly prevalent in ancient” sites.

Brandi summarized the most important elements of conservation in regard to works of art,
including architecture and its branches, in his theories. He emphasized the uniqueness of each,
as well as the importance of the historical-time crucial definition as the foundation for every
restoration effort. Also emphasized by him was the significance of preserving historical
authenticity. The theory explains the critical process that must take place whenever a modern
restoration is planned, and in doing so, it helps to develop a sort of restoration language or basic-
methodology, the application of which necessitates a mature historical grasp of the subject
matter. Brandi's theories can be considered a paradigm in the formulation of restoration and
conservation policies that is recognized throughout the international community. He has served
as the primary direction in the educational and academic programs of numerous specialist
degrees, faculties, and departments, as well as the international courses offered by the
International Center for Conservation of Resources in Rome and in other parts of the world. As
a starting point for the formation of the Venice Charter, as well as the “production of additional
declarations and directives for the conservation policy of cultural heritage, this idea has been
used extensively. Brandi himself was involved in the development of a new directive for the
administration of the Italian government in 1972, known as the International Restoration”
Charter (International Restoration Charter).

3.4 Analysis, reflection and browsing on the theories of Cesare Brandi

Cesare Brandi was a major influence on Italian conservation philosophy and practice. His
conservation theory was inextricably linked to practice, since he proposed numerous rational
rules for conservation and restoration methodology. “Cesare Brandi (1906–1988) researched
restoration theories in art and architecture in the early” 1930s. Brandi asserted that restoring a
'piece of art' in “general necessitates the identification of its unique aesthetic, historic, and
'claims' characteristics. He also placed a premium on aesthetics in order to re-establish the
work's potential integrity in architecture”. According to Rouhi's idea, “Brandi established a
critical restoration theory and expanded upon it by developing a framework for the meticulous
restoration and conservation of historic buildings and structures. Brandi studied many types of
restoration, ranging” from "basic respect" to a "radical operation," and concluded that the
uncertainty in restoration concepts resulted from this ambiguity. As stated by Matero (Matero,
2007), “Brandi viewed restoration as primarily a critical effort, emphasizing the
"reestablishment of the potential unity of the piece of art, to the extent that this is possible
without causing an artistic or historical faux pas or erasing the passage of time entirely." Thus,
from Brandi's perspective, restoration was the process of restoring a historic structure to its
original state without introducing artificial things or even erasing evidence of degradation.
According” to “Schädler-Saub” (Schädler-Saub, 2008), “Theoretically, Brandi characterized
restoration and conservation as a methodology that begins with the identification of a piece of
art and its physical condition within its aesthetic and historical context, while keeping in mind
its future” transmission. (Yazdani Mehr, 2019)
72
Jokilehto “was convinced According to Brandi, because the construction material of a heritage
building is the result of human labor, employing the same sort of material for restoration” may
produce "chemically the same substance" but would have a "different significance" “Under
these circumstances, restoration lost its original meaning and became historically and artistically
fake. (Jokilehto J. , 2007) However, on the contrary to Jokilehto, Mimoso stated that Brandi
believed that material could be sacrificed due to the importance of the aesthetic value of a
cultural heritage building. Schädler-Saub (Schädler-Saub, 2008) believed that Brandi viewed
material as an integral aspect of the aesthetic message sent by a work of art and that it is
imperative to retain material that demonstrates” the artist's process of creation.

Brandi viewed building as a "work of art" that “could be restored with an artistic eye. Brandi
continued by stating that restoration must be limited to the original structure and must be guided
by the building's conceivable harmony in light of its aesthetic and historical features. Thus,
Brandi prioritized historical and aesthetic aspects when restoring a historic” structure. However,
as stated by Matero (Matero, 2007), Aside from aesthetics, Brandi viewed functional
performance as a factor in restoration, which differed “depending on whether the work” was
classified as "industrial" or "art." As a result, Brandi's approach of restoration was based on the
aesthetic, historical, and practical aspects of old structures, rather than on their structural
integrity. In 1963, “Brandi articulated three additional principles in regard to the restoration of
a historic” structure:

• Any architectural re-integration “should be easily recognizable at close distance but, at


the same time, it should not offend the unity that is being restored”;
• A part “of material that directly results in the building’s image or architecture is
irreplaceable since it forms the appearance and not the structure”;
• Any “restoration should be carried out in way that it will not be an obstacle for necessary
future structural interventions”.

Brandi concentrated on a methodical restoration strategy that would allow for more restoration
work. He believed that all restoration work must be done in a way that is respectful to the original
structure, and hence must be distinguishable. Moreover, Brandi believes some materials cannot
be replaced because of their significance in expressing the most important characteristics of a
building. As a result, Brandi's restoration idea indicated the necessity of conservation as well.
According to Brandi, the primary goal of conservation is to preserve a work of art. Several
fundamental aspects for the preservation of historic buildings, according to Barassi, were
emphasized by Brandi during his tenure:

• A “conservator must not imitate an original architect’s design style or interpret the work
subjectively, instead, a conservator designer must respect the time of creation of a work
or project, and thus try to conserve a historic building based on its era” “time”;
• It is “important to prevent restoration interventions in the form of removing the original
signs of decay on a cultural heritage building, which hide the real age of the building;
• Any conservation work on a cultural heritage building must be reversible”;
• A “conservator architect must plan conservation based on the specific building needs
and condition of the work. Thus, he must have knowledge about a historic building”.

Brandi “classified all conservation work into three categories: physical form and fabric, history,
and context, all of which must remain recognizable after alteration”. Thus, Brandi was concerned
73
with "loss and compensation," which were regarded as critical issues in the conservation of art
and architecture. According to Wong, Brandi's thesis was worldwide accepted when
conservation regulations and UNESCO mandates were developed.

Brandi was a twentieth-century theorist who addressed the current trend of restoration and
conservation. He placed a premium on aesthetic and historic qualities when it came to the repair
and conservation of old structures. His thoughts and practices influenced the development of
national and worldwide conservation strategies. (Yazdani Mehr, 2019)

3.5. Interpretations and theoretical analysis on the architectural principles of


interventions. Consolidation of mortar from the architectural point of view

Consolidation “procedures covering architectural tile schemes fall into two distinct materials
skills base: consolidation of the mortar substrate and the ceramic itself. Consolidation of the
mortar substrate is usually achieved by introducing a material homogeneous with the substrate
itself in a liquid or semiliquid consistency which will bind the degraded or fragmented mortar,
fill voids, and adhere to the adjacent surfaces, and in so doing, stabilize the degraded substrate
which threatened the security of the ceramic layer. It also implies the use of a treatment method
which will avoid the wholesale, and potentially damaging, lifting and removal of tiles in order
to replace the original mortar substrate with the new” one. (Oddy & Linstrum, 2005)

3.5.1 Degradation and consolidation of old mortar

The constituent ingredients of medieval lime mortar element are a mixture of lime, sand, and
pozzolanic material in varied proportions and grades. They can decay due to a variety of
circumstances, including water infiltration, “frost action, impact damage, or chemical alteration.
The outcome is frequently cracking, fissures and fractures, or spaces that allow loose or unseated
tiles to become loose. If the underlying mortar is significantly deteriorated or damaged, valuable
tiles become susceptible to damaged or worn edges, fractures, or, in the worst-case scenario,
complete loss”.

“Consolidation strives” to “rejoin loose tiles and provide a stable base while retaining the
medieval mortar's original appearance. Lifting or relocating loose tiles from their original
placement is not a good idea, as it is rarely possible to reseat them exactly as before, unless the
tiles have traveled sufficiently from their original location that lifting and resetting is beneficial.
Due to the fact that no two medieval mortar mixes are identical, it is critical to conduct a few
simple trials to develop a slurry mix of hydraulic lime and water, possibly with the addition of
a small amount of fine sand, that will flow far enough beneath the tiles to fill voids and provide
an adequate bond and set between mortar and tiles. Slurry is a viscous mixture that retains its
fluidity. By use a slurry rather than the conventional firm mortar mix for pointing, the
probability of the tiles becoming unseated throughout the procedure” is reduced.

74
3.5.2 Causes of degradation in nineteenth and twentieth century mortars (Oddy &
Linstrum, 2005)

The visual and auditory diagnostic “of failing mortar in nineteenth- and twentieth-century tile
schemes is quite similar to that of seventeenth and eighteenthcentury tile schemes; bulging
surface planes and a hollow sound when tapped. The causes are considerably different; thermal
shock is less frequent because the typically used glue, Portland cement, is resistant to thermal
shock except in extreme circumstances such as fire damage. Normal fireside temperatures
combined with continuous heating and cooling are most likely to result in tile loosening from
the mortar bed” (element joint).

Excessive volumes of water following flood damage frequently cause the mortar's adhesion
qualities to fail while the grout structure remains intact, frequently resulting in a hole behind the
tiles despite their continued attachment to one another. While the same problems might occur
purely as a result of shifting load, when water infiltration is also present, the situation is typically
aggravated. When mortar adhesion deteriorates in combination “with external stress, such as
footfall or vibration, or with continued settling or subsidence, the tile layer can suffer
catastrophic failure in the form of fracturing or spalling around the tile edges, or even complete
structural collapse, as illustrated in Figure 4”.

Figure 4. Complete “collapse of a tiled floor after severe water” penetration (Oddy & Linstrum, 2005)

3.5.3 Consolidation of nineteenth and twentieth century mortars

The “main purpose of the consolidation procedure is to fill the spaces behind or underneath the
tiles and to create a new adhesion between the tiles and the substrate without having to dismantle
major portions of the entire scheme, which would cause unsettling, altering, and unnecessarily
severe damage. While technically achievable without the removal of some tile material to allow
for the injection of new slurry mix, which will bond all of the parts together, this is not always
the case in practice. The removal of tile material without causing harm to surrounding material
will be covered in greater detail later in this chapter, but there are certain apparent considerations
to keep in mind when deciding which tiles to remove and which to leave” in place.

They “must be spaced and uncommon enough so that they do not cause more modifications to
the overall scheme than are necessary, yet close enough so that the newly bonded sections are
adjacent in spread; nonetheless, an efficient consolidation can be achieved even if some gaps in
the bonding remain. Clearly, it is preferable to remove a broken tile rather than a perfect example
75
if the option is available, and, again if the option is available, it is always preferable to forfeit
undecorated tiles in colors and textures that are most easily copied rather than” a flawless
example.

There “should be little structure in the cement-based slurry mix, which is normally one part
Portland cement to four parts extremely fine sand. If the original mix contains lime, one part
hydrated lime may be added to make up for the lack of structure. Following the customary
thorough pre-wetting, the mix can be injected into the voids by narrow copper pipes that can be
either gravity fed or manually pushed under pressure. Copper pipes are preferable to plastic
tubes because they are hard yet may be curled into usable shapes, and one end of the tube can
be flattened to reach as far into the voids as feasible. Copper pipes are more expensive than
plastic” tubes.

A very tedious procedure, feeding mortar slurry through narrow copper tubes is comparable to
watching paint dry, according to some observers. Since “it is impossible to feed down the pipes
after the hardening process has begun, new mortar must be mixed on a regular basis, and it will
easily harden inside the pipes, leaving them worthless; therefore, a plentiful supply of copper
piping is required. Because there are no standard or readily available equipment for doing this
duty, it is frequently left to the conservators to devise their own devices that are tailored to the
specific scenario. A number of technical challenges can arise during the operation, including
variations in the degree of prewetting, the component parts and ratios of the slurry mix, and
whether or not to employ gravity or pressure to force the slurry mix down the tubes. The
diameter and length of the tubes are also important factors in determining whether or not the
exercise will be successful. The time and work involved in building test boxes, similar to those
described for medieval mortar consolidation, in which to carry out trials to perfect the procedure
for the specific area is well worth it if the alternative choice is to entirely lift and reset a whole
scheme”. (Oddy & Linstrum, 2005)

76
CHAPTER 4.
Engineering theoretical framework

77
4.1 Literature Review. Observations on Design Codes in the past and now, related to the
Masonry Structures Design

Many researches, manuals, publications and books that deal with specific cases of masonry
structures have been worked on as quite widespread objects, and in addition these have resulted
in summaries of standards, normative and codes which define the principles of design, analysis
and evaluation methods. Calculation models as well as the criteria which must be met both the
elements in particular and the structure as a whole. Since masonry structures are seismically
sensitive many of the works and codes deal precisely with their behavior in terms of ground
movements.

Everything of this kind of research is based on experience of failures and collapsed structures
after strong earthquakes, experimental reviews as well as accounting theories. Today there are
a lot of theories and models studies which offer experimental and numerical results in the
mentioned cases but also raise many dilemmas that some of them are very good for reinforced
concrete frame cases but in regard to specific cases with small differences can differ up to 2-3
times from one another or from experiments.

This is a consequence of the great variety of constituent elements, construction methods,


technological level, and at the same time shows the difficulties which accompany these
structures. This in part also justifies why this area of accounts has lagged behind compared to
reinforced concrete or steel structures.

During the work in certain cases the author underlines such cases when there is a difference
between the authors or the norms. As in other fields in the last century, this field has been
developed by the application of powerful computers and adequate application programs for this
purpose. These are mainly based on finite element MEF methods which give fast and detailed
results.

For the use of models with microstructure where the materials are elaborated with their real
specifics and characteristics, a powerful computer or software and time for calculation are
needed, therefore more often macrostructure models are used which, in addition to simplicity,
offer satisfactory results.

Despite the fact that it is estimated that American standards for masonry such as FEMA (Federal
Emergency Management Agency) are considered more advanced in the paper, the author
compares his experimental results more with European Normative EN (Eurocodes) as more
current as well as in some cases in the former Yugoslav and Greek standards. Just as well as the
standards of Albania (Technical code of design) when it comes to recognizing the existing
structures which must have been worked according to them.

4.1.1 European Standards, Eurocodes related to the study of masonry and mortar

The general principles of European codes and standards also apply to these parts, which despite
the definition of the principle and unique methods, but for certain aspects allows and is preferred
through National Local Annexes the acquisition of parameters obtained from experiments to
approve specific values of local character.
78
Eurocode 6 respectively EN 1996-1-1: 2005 in its entirety elaborates the masonry structures,
where in addition to the introductory part (field of application, symbols, references,
terminology, etc.) deals with design principles, constituent materials, types of walls and
connections, possible loads, stability, durability, state of use and boundary condition, execution,
details, physics, etc.

Eurocode 8 which studies the seismic impact in its entirety in its chapter 9 defines the specifics
of masonry and elements, ie the minimum conditions that must be met to be used for seismic
areas. Standards are:

EN 771 - (1-6) elaborate masonry elements from different materials;


EN 772-1 methods of examining elements of compressive strength;
EN 998-1.2 elaborates the mortars;
EN 1052- examines the walls configuration and design etc.

When it comes to the application of e.g. reinforcements with concrete, cell or polymer fibers
apply adequate standards to the used materials. These will be analysed and discussed more
detailed and specifically in the case studies reviews in the following chapters of the study.

4.1.2 Observations on the current Albanian Code of Design and Implementation for
masonry structures according to KTP-1978

This technical condition defines the “method of calculating the wall section and the foundation
section. For constructions in seismic regions, the technical instructions defined in KTP 2-78[5]
are taken into account. These general guidelines were published in 1978. This technical code
specifies the calculation of the wall and foundation section” with limit state method of design.

Loads “and their combinations are taken in accordance with the technical instructions, which
are defined in KTP 6-78 (Determination of loads in civil and economic buildings). This code
specifies all cases of masonry with bricks, stones, concrete block and concrete mix by stones,
the mark and plasticity of the mortar, the thickness of the mortar joints and their leveling, the
height of the row, the way of connection and the quality of construction”.

The “most important part of this code is shown below. First the calculation parameters of the
wall are shown. Exactly the calculation resistance is the product resulting from the
multiplication of the normalized resistance versus the homogeneity coefficient. It varies
according to the tense condition of the element and the type of materials used to” build the
structural wall.

5
Albanian National Design Code, KTP/2-78
79
Table 1. Compressive strengths for brick walls, with row height over 12cm (KTP-78)
Mortar grade [kg/cm2]

No. Brick grade [kg/cm2] 100 75 50 25 15 4 0

1 “150” 22 20 18 15 13.5 12 8
2 “100” 18 17 15 13 11 9 6
3 75 15 14 13 11 9 7 5
4 50 - 11 10 9 7.5 6 3.5

Table 2. Compressive strengths for concrete block walls, with row height over 18cm (KTP-78)
Mortar grade [kg/cm2]
Concrete block
No. grade [kg/cm2] 100 75 50 25 15 4 0
1 100 20 18 17 16 14.5 13 9
2 75 16 15 14 13 11.5 10 7
3 50 12 11.5 11 10 9 8 5

Table 3. Compressive strengths for stone walls and foundations with kave stones (KTP-78)
Concrete grade [kg/cm2]
No. Stone grade [kg/cm2] 100 75 50

1 Over 200 27 18 18

2 Less than 200 - 15 15

Table 4. Calculation resistances in central traction and shear (KTP-78)


Mortar grade [kg/cm2]

No. Stressed state 100 75 50 50


1 Axial tension:

Combined intermittent joints 1.6 1.1 0.5 0.2


Continuous horizontal joints 0.8 0.5 0.3 0.1

2 Shear
Combined intermittent joints 1.6 1.1 0.5 0.2

Continuous horizontal joints 2.4 1.6 0.8 0.4


3 Main Stress in tension 1.2 0.8 0.4 0.2

80
The following interpretations are the calculations for the modulus of elasticity:

• For calculating walls according to bearing capacity (resistance and static stability):
E = 0.5* E0 (Eq. 1)
• To determine the deformation of the wall is used:
E = 0.8* E0 (Eq. 2)
where: E0 - initial modulus of wall elasticity, which for unreinforced walls is calculated by the
formula:
E0 = α * Rn (Eq. 3)
where: α - elastic characteristics of masonry and is obtained according to table 2.5
Rn - standardized resistance to central pressure of masonry
Table 5. Elastic characteristics of masonry, “α” (KTP-78)

Mortar grade [kg/cm2]


No. Wall type 100-50 25 4 0

1 Brick wall and concretee blocks 1000 750 500 350

2 Brick wall with vertical holes 2000 1500 1000 -

3 Brick wall with horizontal holes 1500 1000 750 -

4 Stone wall and concrete blocks 2000 1000 750 -

4.1.3 Masonry structures, a brief description

Represent the assembly of interconnected elements with certain mortar. The role of the element
itself is the shaping of the wall as well as the acceptance of external influences, while the role
of the mortar is the "homogenization" of these elements playing the role of the material which
connects the elements and fills the spaces between them.

The constituent elements are intertwined so that together as a whole they create a stable structure
usually in the form of vertical walls, vertical cylinders such as minarets, wells and chimneys,
but with dedicated skill arches, bridges and curved coverings are formed - domes like cylindrical
shells or even spherical.

4.1.4 The walls definition

They represent the elements - the vertical plates of the structure which are mainly loaded in its
plane and that in compression. The interweaving of the walls at the base as well as its stiffening
with mesquite tiles forms massive structures where the walls are retaining d.m.th. receive and
81
forward external loads as well. But lately the bearing capacity of the structure is entrusted to
reinforced concrete or even metal structures where the walls have a dividing character which
are loaded only with their own weight and eventually by the wind.

Based on EN they are categorized into three groups:

• Unreinforced masonry;
• Masonry with reinforced steel elements;
• Reinforced walls.

Also characterized by the material:


• Filling elements;
• Retaining elements (retaining and divider).

Since the object of study of this paper is the bearing capacity of masonry structures under
seismic impact, in the following we will concentrate on the walls with special emphasis on the
walls of clay elements, as typical objects of special interest for our territories.

4.2 Impacts affecting the performance of structural walls

Due to the internal structure of the combination of elements and mortar, the walls as a whole
present inhomogeneous and anisotropic tiles. They have good bearing capacity in their own
plane while normal ones have relatively little resistance. For this reason masonry objects at the
base, with the walls as elements are usually combined with each other at an angle of 90 o forming
a stable structure.

In daily conditions they are usually loaded only with vertical loads - by the own weight of the
structure, therefore even within it the state divided into pressure dominates even though there
are elements of the three-axial state. In these cases it is assumed that horizontal loads e.g. winds
that cause normal impact on the wall plane, ie bending have a relatively small impact and
withstand the weight itself without causing high eccentric pressure.

According to EN norms, masonry structures as a whole are calculated based on the general
principles and principles defined in EN 1990. For example the boundary condition of the
structure are analyzed as well as the bearing capacity capacity of the element respectively the
structure. In all cases the internal momentum must be greater than the external influences with
which the structure is charged. Load analysis is done including partial safety factors as well as
their combinations which are defined in EN 1991.

4.3 Materials and components of masonry structures

Masonry as a structure is mainly a combination of filler elements, and the joints between them
"mortar", and sometimes other elements to increase the stability of the wall structure, such as
wooden elements, reinforced belts, metal rod elements, polymer fibers. FRP etc.

82
4.3.1 Filling elements, masonry units

These are materials and elements, which in terms of shapes and dimensions are suitable for use
and enable a combination in creating a structure with load-bearing masonry. They are found in
nature or produced with a relatively simple and quite economical technology. They are
considered as materials with massive geometric shapes, with high resistance against to
atmospheric conditions and aggressiveness of the environment, they are refractory, aesthetic
and ecological materials.

Regarding the physical-mechanical characteristics they usually possess good resistance to


compression and are used for vertical retaining elements, such as retaining walls which accept
and transmit vertical loads from the structure to the foundation. Materials can be natural stone,
processed stone, various products from baked clay, concrete, calcium silicate, aerated concrete,
etc.

In applications in the design of structures with natural stone, the main challenge is in finding
suitable shapes and dimensions for their combination into a whole, as well as need large amounts
of mortar, are very sensitive to horizontal "seismic action" ". At the same time, this complicates
the account, ie the verification of stability for such structures. With the application of processed
stones either only in the corners of the building or as a whole, the stability and functionality has
been improved, while the needs for processing - stone carving have made the execution more
difficult and have made it uneconomical for more comprehensive use.

With the application of elements of regular shapes, processed from baked clay the construction
became easier, more economical as well as the structures gain in stability. Today in use we have
a large variety of these elements with high mechanical quality as well as with different shapes
and dimensions and also with different percentages of voids depending on the needs, ie
destination.

With the development of production technologies, other elements were also advanced, such as
elements under steam pressure - autoclaves made of calcium silicates, which are characterized
by a more regular shape and good mechanical properties. Elements from aerated concrete can
also be mentioned, which are characterized by regular shapes and low volumetric masses.
Concrete elements with natural aggregates or even with recycled materials can also have
frequent use.

The elements are grouped and evaluated with numerous standards and norms in this field where
during the work the classifications according to EC 6 will be used, respectively EN 1996-1.
Depending on the materials we use, we distinguish 6 groups of elements as well as the standards
which specify the requirements for them:

• Elements from clay (baked) EN 771-1


• Elements of silicates EN 771-2
• Concrete elements EN 771-3
• Aerated concrete elements EN 771-4
• Elements of artificial stone EN 771-5
• Elements with natural stones EN 771-6

83
According to EN 1966-1 today the elements are divided into 4 groups depending on the basic
materials and the percentage of voids.

4.4 Mechanical properties of structural unreinforced masonry elements

4.4.1 Compressive strength of the masonry materials

Compressive strength is the main mechanical property of the element which has a great impact
on the compressive strength of the wall as a whole. It is examined in the prepared samples by
placing them on uniaxial presses with the destructive method, depending on the direction in
which it will be placed on the walls. It is still a challenge to evaluate the compressive strength
in the laboratory and how much it corresponds to its bearing capacity inside the wall. The author
Crisafuli emphasizes "the compressive strength of the element according to current standards
does not represent its real uniaxial resistance due to the effect of stiffness of the tiled element
during the examination" and the author complements it due to the ratio of dimensions and the
effect of mortar.

Due to the non-flat surfaces one of the surface treatment methods should be foreseen such as
abrasion, leveling with layers of plaster mortar, leveling with layers of cement mortar, leveling
with layers of sulfur mixtures; these processes which cause an entanglement - cooperation
between the plate and the element, preventing the free expansion that the element actually has.
Element reviews are known which try to reduce this effect e.g. increasing the height of the
element compared to the base (ratio: H/B up to 5 times), the use of "combs" special devices
which allow lateral movement of the contact surface, the use of soft substrates such as corks,
layers of fibers and wood, mediapan of different resistances and thicknesses, these layers have
a coefficient of succession close to zero.

4.4.2 Tensile strength of unreinforced masonry

It also has its own importance especially when dealing with walls that are also subject to
horizontal pressure. It is significantly smaller than the compressive strength and are linear quasi-
instantaneous fractures. It can also be obtained through examination based on direct traction,
but it is quite complicated - it requires special equipment and materials for the realization of
traction, so with great reliability are used methods in bending (fracture module) or even in
indirect traction - in cracks. These do not achieve the same results but a correlation can be
established between them. There is also a tendency to find the correlation between tensile
strength - usually that of bending and compressive strength, which according to different authors
we have large differences

4.4.3 Modulus of elasticity and Poisson coefficient for masonry elements

The modulus of elasticity can result from the working diagram σ-ε of the element where it is
defined as the tangent which passes through the point 0 and 1/3 of the compressive strength of
the element. This diagram is relatively elastic in blocks while in bricks it shows a plasticity.
84
Experimental results show a distribution of results so we have distinct preferences. While in
concrete elements it ranges from 3-12 GPa in clay elements it is approximately:
Eb = 300 f 'cb (Eq. 4)

According to Kirtsching:
Eb = 980 f ' cb 0.77 (MPa) (Eq. 5)
While the Poison coefficient according to Atkinson, McNary and Abrams ranges from 0.13-
0.22 (without specified materials) while according to Ameny this value ranges from 0.07-0.14.

4.5 Mortar and binders

4.5.1 Types of mortars

The mortar serves for the connection, ie the adhesion between the elements of the masonry as
well as for the filling of the spaces between them. In the beginning, mortars based on bituminous
bases were used, mortars with lime binders, with hydrated lime, and lately, continuous mortars
are usually used - cement, lime, aggregate, water and, if necessary, additives. As a bonding
material it has an important role in the bearing capacity of the whole structure and especially
when the shape of the wall fracture is made in the cut.
Based on the Eurocode-6 classification according to qualities and use we have the following
types of mortar:
• Mortar for general use which uses only dense aggregates and has a joint width > 3 mm
• 1-3 mm thin layer mortar is designed-prefabricated to meet the specific requirements of
the structure (eg adhesive of aerated concrete or silicate elements)
• Light mortar with volume mass <1500 kg / m3 - where filling the aggregate is light as
e.g. perlite, expanded clay, pumice, etc.

According to the production concept, mortars can be:


• Designed (according to cases and requirements)
• Ordinary (according to general descriptions) And according to the way of preparation:
• Pre-prepared
• Semi-prepared

The recipes are mainly prepared on the basis of experience as a mixture of cement, slaked lime
and sand in volume ratios e.g. for mortar of general purpose. Powdered lime (hydrated) or even
cement mortar can be used, which is actually categorized as M5.

85
Table 6. Orientation ratio by volume of mortar components for mortar brands
Approximate mixtures by volumes
Mortar
Average compressive
class Aggregates in relation to
strength Cement Quenched lime
connectors
M-2.5 2.5 1 1.25-2.5 2.25-3
M-5.0 5 1 0.50-1.25 2.25-3
M-10 10 1 0.25-0.50 2.25-3
M-12 12 1 0-0.25 3

In the table are the orientation values because the final quality of the mortar depends not only
on the ratio but also on the quality of the ingredients themselves, e.g. grade of cement, generosity
of lime as well as granulometric composition of sand. While the role of cement is in increasing
the strength and durability of mortar, the role of lime is to improve workability, initial adhesion
and absorption - water retention.
The role of the compressive strength of the mortar does not have a significant impact compared
to the element itself, but in cases of impacts in tensile or even in some cases in cutting the role
of the mortar increases.

The thickness of the joint itself has a significant impact, which is preferred to be as small as
possible (Naom 1994) and the ratio of the thickness of the element compared to the thickness of
the joint to be larger. The thickness of the mortar in the horizontal joints for clay elements is
preferably 8-15 mm, and it is mandatory to fill the vertical joints (10 mm) with the exception of
areas with low seismicity.

In cases of seismic when poor quality mortar has been used, it has led to the disintegration of
the elements, therefore based on EC 8 are determined the minimum criteria for application of
mortar in seismic areas:
fm, min ≥ 5 N/mm2 for unreinforced masonry walls and;
fm, min ≥ 10 N/mm2 for reinforced walls

These calculations and equations are summarized on the research and discussions conducted in
the framework of field investigations, expert consultations and calculation reports found in the
archives (AQTN).

4.5.2 Compressive strength of mortar

Presents the main quality of mortar. It depends on many factors such as the type and percentage
of connectors or even connectors when there is more than one as well as the ratio between
connectors. Much also depends on the filler (sand) and the granulometry and shape of the grains,
mineralogical petrographic composition, the amount of water or water / binding factor, the
method of preparation and placement in the work. Mortar evaluation is done through laboratory
samples (chapter 6, section 6.1.5.1). In this case it should be noted that due to different
maintenance conditions, paving in thin layers (8-15) mm, rapid absorption of water in the mortar

86
from the elements in the walls {changing the ratio W/(C + G) }, inadequate maintenance and
reinforcement due to the triaxial condition in which the mortar works inside the wall but not in
the samples in the laboratory, etc. Mortar tested in the laboratory is not a reliable indicator of
mortar on walls. According to the author Schubert, also (Cullufi pg, 23) the difference can be
of the level 0.5-1.5.

4.5.3 Other mechanical resistances

Also other qualities of mortar such as tensile strength, shear strength, abrasion resistance,
adhesion, are parameters that affect the behavior of the mortar and the wall as a whole. Adhesion
and friction also depend a lot on the masonry element, so even today, in the case of
micromodeling calculations, the mortar-element interface parameter is very important. As a
porous material it is very sensitive to the effect of freezing - thawing so special care is given to
this parameter.

Durability - the longevity of the mortar depends mainly on the petrographic mineralogical
composition of the sand, binder, as well as the aggressiveness of the environment in which it is
used, the composition of alkalo-silicates and soluble chlorides, which should be given
importance to wet mortar. In many cases, special binders or various additives are applied -
additives to improve certain qualities.

4.4.4 Modulus of Elasticity, Slide Modulus and Poisson Coefficient

Based on these parameters and their relationship with the analog parameters of the masonry
element itself comes to the internal redistribution of partitions within the wall that must be taken
into account in the case of models with microstructure. The modulus of elasticity results from
the working diagram σ-ε as second module between 0 and 0.5 fm. According to Brown and
Whitlock authors the initial module is 15-25% larger than the second one.

Em = 1000*f’m (Eq. 6)

The slide modulus is calculated:

G = 0.4*E (Eq. 7)

Whereas the Poisson coefficient ranges in a very wide range of (0.07-0.25) although for low-
strength mortar - average values 0.15-0.250 are more realistic.

Adhesion, tensile strength, resistance to environmental aggressiveness are also parameters that
must be analyzed for certain cases (EN 1015-1-19). In the case of micromodeling, adhesion
represents the third parameter that is well considered - mortar interaction.

87
4.5 Concrete used for antiseismic elements in masonry

It is usually used to form reinforced belts or even to fill large holes inside the elements. In these
cases they "tie - sting" the wall but in reality are not retaining. Must have the minimum class
C12/15 and the maximum grain is conditioned by:

dmax> b min of hole / 5 or protective layer > 15 mm

Since a fluidity is required to fill the holes then additives such as plasticizers are used and those
to reduce shrinkage. In the case of repairs, concrete (mortar) with microfiber is also used, such
as. torkret concrete.

4.5.1 Reinforcement

It is used in reinforced walls to increase the bearing capacity of the wall with emphasis in the
transverse direction as well as to increase the ductility of the wall as well as as anchors for the
cooperation between the concrete frame and the wall. If the concrete belts are reinforced
according to EC 2 as constructive reinforcement, and in specific cases the usually thin
reinforcement Ø 6 or Ø8 can be placed in cooperation with the mortar in the horizontal joint or
even in the case of joint reinforcement or specific products of truss shape are found or special
stirrups.

4.6 Use of FRP Materials in masonry structures

Today, the use of polyester nets or microfibers that are fired directly into the mortar has started.
Also, every day more and more glass fibers, carbon fibers or even aramid fibers are used, in
combination with their resins. These are very current, especially when it comes to various
adaptations in the structure.

4.7 Compressive strength of retaining walls (brick and mortar together)

Masonry structures show good behavior, usually when under the action of normal compressive
forces on the horizontal joint of the mortar. Initially, for low force levels, the stress-strain
dependence is linear. As the force increases, the bearing capacity of the wall behaves as non-
linear and normal cracks begin to appear in the horizontal joint. Thus, the wall is divided into
several vertical strips in the form of columns, until it loses stability and comes the point of
collapse or panel destruction.

By the action of the compressive force the deformations in the mortar would naturally be greater
than those of the filler elements. However, since we have friction between the mortar and the
elements, then tensile stresses appear in the elements. At the same time the mortar, due to the
reinforcement by biaxial action can withstand greater stresses in compression. This leads to the
compressive force on the walls being limited by the tensile strength of the elements.

88
Figure 5. Cracks in normal elements in tensile stress and Tensile stress in elements including mortar
deformation

The compressive strength of the walls is determined experimentally. When this is not possible,
compressive strength is determined based on empirical expressions derived from experiments
in different countries.

Secondary factors affecting the compressive strength of structural walls

There are two main factors that affect the resistance to wall pressure:

• Tensile strength of elements (gap elements are unfavorable in relation to this aspect)
• Compressive strength of mortar (greater resistance of mortar reduces lateral
deformations).

But, there are other factors that affect the resistance to wall pressure. These factors are:

• Thickness of the mortar in the horizontal joint (recommended height 8-15mm);


• Wall construction, forms and methods of element connections;
• Total filling of joints or meeting directly and through interlocking scaling;
• The number of horizontal joints, elements with higher height are more favorable in this
respect;
• Wall humidity - water absorption and water retention, etc.

4.7.1 Shear-slide resistance of the masonry

It is known from the engineering literature that the shear strength of walls depends on the level
of axial force acting on the wall. However, two different hypotheses have been elaborated to
model the mechanism of destruction in shear to plan walls. One of the hypotheses which has
been accepted by Eurocode EC 6 for the determination of shear strength is based on the friction
theory.

89
According to this theory the wall resistance under the action of shear forces is defined as the
combination of shear strength when the shear force is zero and the additional resistance that
comes as a result of the compressive stress acting normally in the shear plane, i.e. of friction
between the mortar and the elements. In fact the shear strength is the combination of two
different mechanisms, the bond strength and the friction resistance between the mortar and the
filler elements.

4.7.2 Shear resistance for horizontal sliding, Review and reflection according to Italian
literature and NTC-code

The collapse mechanism due to sliding shear occurs by breaking the rows of mortar between the
blocks with consequent sliding between two portions of masonry. The shear strength of the
masonry is evaluated using the Coulomb internal friction criterion which takes into account the
compressive stress acting in the masonry. As the compression tension increases, the resistant
shear stress will increase.

The resisting tension must be multiplied by the compressed portion of the masonry only,
assuming a linear diagram of the compression tension.

Vt = L ’⋅ t ⋅ fvd (Eq. 8)

Vt = shear resistance for horizontal sliding;


L = compressed length of the masonry wall;
t = thickness of the masonry;
fvd = resistant tangential tension of the masonry in the presence of compression.
The above formula is in the Italian code, specifically with number 7.8.3 - NTC2018

Figure 6. resistant shear - break by shear-sliding

90
L' - reactant base zone obtained, assuming a linear distribution of the compression stresses in
the elastic phase, in the absence of tensile strength.

Characteristic resistance of masonry in shear:

fvk = fvk.0 + 0.4 * σn (internal attraction criterion – of Coulomb) (Eq. 9)

fvk.0 – characteristic shear strength of masonry in the absence of axial stress;


σn – average normal voltage due to vertical static loads;
fvk – characteristic resistance of masonry to shear in the presence of axial stress.

In case of decompression of the masonry, the compressed length L 'of the section is canceled
and therefore the shear resistance due to horizontal sliding becomes zero.

4.8 Observations and interpretations on the experimental tests

The typical experimental tests performed on wall panels, macro-elements consisting of at least
3 panels of "bricks", are as follows:

Figure 7. Pure shear test (faces remain parallel), shear and bending test, simple compression test,
diagonal compression test

The four tests are to be understood as conventional as they originate rather complex and difficult
to compare tension states in the panel. The diagonal compression test is usually taken as a basic
test for the characterization of the shear characteristics of the masonry on the basis of its
simplicity of execution and knowledge of the stress distribution inside the panel.

The simple compression test, on the other hand, highlights the behavior of the panel under
vertical loads. To extend the results to a generic case of normal stress and shear on the panel,
suitable resistance criteria are generally required, capable of capturing the response in all
possible combinations.

91
4.8.1 The collapse mechanisms

The following are the possible breakdown mechanisms of the wall panel:

Figure 8. First shape of the collapse mechanism, sliding of joints

Sliding of joints. This breakage is common in strong brick masonry and relatively weak joints.
It generally occurs if the value of the Pv component is limited.

Figure 9. Second shape of the collapse mechanism, Cracking of blocks

This rupture is caused by the tensile failure of the block. Generally it involves the central part
of the panel. The inclination α depends on the ratio between the vertical and horizontal
components of the applied loads. Generally affects bricks perforated with the use of high-
strength mortars.

Figure 10. Third shape of the collapse mechanism, Combined mechanism

The crack generally follows the diagonal of the panel. It affects both the joint and the brick. It
is a collapse that generally occurs when the mortar and brick have comparable strengths. It is a
type of failure that generally affects the walls due to a wide variability of load combinations.

92
Figure 11. Third shape of the collapse mechanism, Crushing in the vicinity of the load devices

Crushing in the vicinity of the load devices - It is a localized breakage generally due to a reduced
size of the load application devices.

4.8.2 Reviews and analyzes of masonry constituent materials

The quality required by the literature for the basic elements examined in Eurocode-6[6] or
Eurocode-8[7] that deals with seismic conceptions, analysis of certain analogous standards, or
other specific requirements, should be confirmed by laboratory or on-site examinations.

In order for the result to be truly representative, as adequate and reliable as possible for research
and to have a crucial role, there is the number of material samples as well as the way of taking
them, sampling which must be done professionally in no case with selection of elements or
within a small quantity. It is normal that even for this there are many standards which define
each application case and relevant detail which affects the results obtained.

Also special attention should be focused to the maintenance of samples as well as their
preparation for examination, as well as the examination and analysis itself which should be
carried out as provided by the relevant standards.

4.9 Information for structural assessment: knowledge levels according to Eurocode

In order to choose the right type of analysis and appropriate values of reliability factors related
to knowledge levels, the following three levels are defined:

CL 1: Limited knowledge
CL 2: Normal knowledge
CL 3: Complete knowledge

Factors that determine the appropriate level of knowledge (eg class 1, class 2, or class 3) are:
Geometry: the geometric features of the structural system and some non-structural elements (eg
filler masonry) can influence the reaction of the structure.

6
Eurocode 6 - Design of masonry structures - Part 1-1: General rules for reinforced and unreinforced masonry
structures.
7
Eurocode 8: Design of structures for earthquake resistance -. Part 1 : General rules, seismic actions and rules for
buildings.
93
Details: these include the amount and details of reinforcement in the connection structure
between the steel elements, the connection of the interstitial diaphragms to the structure resistant
to lateral action, the connections and joining of the mortar to the masonry and the nature of each
reinforced element in the masonry.

Materials: mechanical properties of materials and their composition.


Levels of knowledge manage to determine the appropriate method of analysis, as well as the
accepted values of reliability factors (CF).

Table 7. knowledge levels according to Eurocode 8, part.3 (CEN Eurocode 8, Eurocode 8: Design of
structures for earthquake resistance Part 3: Strengthening and repair of buildings, 2003)
Knowledge
levels Geometry Details Materials Analysis CF

From original From simulated design Values determined in


architectural in accordance with accordance with
drawings with previous practice and design time standards LF-MRS CFCL.1
Class 1
simple visual from a limited on-site and a certain amount
controls or inspection. of on-site test limits
complete control.
From the incomplete From the original
original drawings of the project specifications
executive project with with a limited amount
limited on-site of on-site tests or an All CFCL2
Class 2 inspection or with a extended amount of
more extensive tests.
inspection.

From the original From the original test


drawings of the report with a limited
executive project with a amount of on-site tests All CFKL3
Class 3 limited inspection or or from on-site
from a detailed on-site detailed tests.
inspection.

4.10 Recommendations for interventions on monumental heritage with a specialized and


specific typology in seismic areas. Part of the state of art

4.10.1 Interpretations summarized from the recommendations issued in Italian case 1986

Numerous interventions in historical and architectural heritage located in seismic areas, carried
out in recent years and still in progress, especially after devastating seismic events, as well as
other seismic events less violent, but still harmful to buildings, often are characterized by
considerable difficulties, related to different orders of factors:

• The lack of clarity in the technical regulations regarding the “technical aspects of the
interventions, worsened by the tendency to improperly apply technical standards”, rules
that have been written for ordinary buildings and not for monumental buildings with a
94
specialized typology such as churches and palaces generally comprising large rooms,
vaulted roofs, frescoed walls and horizontal elements or of precious materials;
• The “conflict between the conservation and restoration needs on the one hand and the
protection from seismic risk of construction and human lives on the other hand, with the
related assumptions of responsibility that are attributed to the professionals involved in
the interventions and to their colleagues working in the bodies control”;
• The lack of clarity, technical, technological and even conceptual or cultural, surrounding
the use of modern materials in ancient constructions;
• The absence of a numerous calculation reports and verification F.E.M. models
recognized as valid for special typologies, an absence that is too often filled in a
completely improper way by the adoption (the models valid only within precise limits
“example of the application of POR-type methods”)[8]. (Tomazevic, The computer
program POR, 1978);

Thus, the interventions on the monumental complexes have often been conceived as a static
restructuring carried out “with a series of massive interventions that take up the culture of new
materials with largely extensive criteria, in particular of steel and reinforced concrete, thus
developing a structural restoration strategy, which seeks to remodel the ancient factories
according to the resistant patterns typical of modern materials. The results of this state of affairs
very often translate into”:

• unnecessarily "heavy" “(if not sometimes counterproductive) interventions, which often


distort the monument from the point of view of its identity and value”;
• Excessively expensive interventions, which are countered by non-interventions in other
architectural organisms, due to the exhaustion of available funds;
• Security guarantees that are often completely illusory, as they are based on unreliable
calculation models;
• Widespread “inability, substantial and formal, to check the effectiveness of the
interventions carried out (think of armed injections and injections of mortars or resins)”;

As an example of the phenomena mentioned above, some design positions that are as
widespread as they are harmful are listed:

• Projects developed without any objective element (knowledge about the structure and
the foundation soils; - systematic use of bored piles (small diameter micro-piles) almost
always proved superfluous to a more careful geotechnical examination;
• Anchoring of massive structures with harmonic steel tie rods injected into the ground;
• Insertion of new structures to which the static function is completely entrusted, thus
reserving only the function (the formal element) to the old structure;
• Insertion “of different structural elements that perform static functions considered by the
designer not compatible with the ancient organism; in this case, in addition to originating
a hybrid mechanical behavior, particular uncertainties can be introduced due to the
interaction of different structural schemes and materials”;
• Attempt to achieve, by means of interventions, a behavior that can be modeled with
schemes typical of new buildings;

8
A simple method for the seismic resistance analysis of plain masonry buildings has been developed in
Ljubljana
95
• Unjustified use, with respect to the present crack pattern and the original structural
conception of the monument, of "seams" and "injections";
• Unthinking use of new materials, especially with reference to durability and interaction
with original materials.

With respect to the above situation, introduces a new implementation of the problem into the
technical regulations for constructions in the seismic interventions on existing buildings, making
it possible to operate in prevention rather than just repairs, as well as throughout the national
territory; the main innovation is represented by the introduction of a double level of objectives
achievable through structural interventions aimed at increasing the resistance of buildings to
seismic actions; in fact, the following are identified:

• The “adaptation interventions, defined as he as a set of works necessary to make


the building capable of resisting project actions equivalent to those envisaged for
new constructions”;
• Improvement interventions “defined as a set of works aimed at achieving a
greater degree of safety against seismic actions without substantially modifying
the overall behavior of the building”;

The conceptual distinction between the two types of intervention mentioned, although not
directly referring to monumental buildings pursuant to article 16 of law 64/74, has significant
importance with regard to the objectives that must be based on an intervention on the
monumental heritage.

By their nature, interventions on the monumental heritage are not included in any of these cases:
the obligation to adapt is in fact triggered in the presence of interventions that can be configured
as elevations, extensions, building renovations and in any case such (substantially modifying
the static and dynamic of the building organism.

It can therefore be said that, in light of the provisions for ordinary construction, the objective of
the interventions on the monumental heritage as regards safety and seismic actions, is
comparable to improvement. In this perspective, it can be concluded that the interventions on
the monumental heritage must be characterized by an increase in safety against seismic actions
without, however, the problem of respecting the formal checks in relation to the seismic actions
of the project envisaged for the new buildings.

Therefore, pending the definition of specific technical standards for monumental heritage, to
which the National Committee for the Prevention of Cultural Heritage from Seismic Risk is
called upon to make a proactive contribution, a line of behavior based on the systematic recourse
to interventions of improvement and on a conduct of design operations that has directed regard
to the cultural value of the building considered and which implies:

• Particular attention to the original materials and magisterium’s, as well as to subsequent


transformations;
• A careful reconstruction of the seismic history of the building, with particular attention
to any repairs following past seismic events;
• A “rigorous and systematic interdisciplinary approach in all the design phases, with
particular reference to the architectural, historical, geotechnical, structural, plant
96
engineering contributions” (if applicable): The use of techniques and materials as close
as possible to the originals, with a severe interdisciplinary critical examination of any
interventions that differ from the aforementioned. Ultimately: in the presence of an
"ordinary pathology or damage" of the monument and in the absence of the constraints
referred to in theoretical restoration manuals. of the aforementioned Decree, the choice
of widespread conservation must be made which, combined with the above mentioned
regulatory concept of improvement, allows to achieve the objective of seismic risk
prevention.

The operations to be carried out will be, by way of example, of the following type:

• Coordinated interventions on the connections, especially if compromised by previous


earthquakes or lack of maintenance;
• Verification and repair of the horizontals (roofs, floors, arches, vaults, platbands) with
mainly traditional procedures (partial replacement of only the degraded wooden
elements, restoration of the tension of chains and spanners, stiffening of the planks with
a second nailed planking, placing new tie rods at low voltage operating floors, partial
reintegration of arches or platbands, etc.;
• Verification and repair of vertical or sub-vertical cracks with traditional procedures in
order to restore the continuity of the masonry structure, even without excessive
stiffening;
• Skiving of the joints, topping up and restoration with traditional mortar of the plasters
where they existed and have fallen, to reintegrate the bearing capacity of the masonry
structure, with attention to any decorated plasters.

It can be observed that the examples now outlined are largely configured as maintenance
interventions, aimed at mitigating degradation and restoring the building to its original capacity
for resistance, or improvements, aimed at increasing the aforementioned capacities without
upsetting the own resistant schemes; only in the presence of one "Extraordinary pathology" due
to defects of origin in the structural conception, or to a very accentuated state of decay, or to
considerable damage, the need arises for a more complex evaluation; this need also arises when
large-scale interventions are configured such as those envisaged within the finalized projects.

In order to pursue the aforementioned objectives, the completeness of the analysis and project
documents is of fundamental importance, as the result of a methodology organized in
operational phases strictly connected to each other through the coordination of the expert in
architectural restoration, so that the lack of a or more phases can only lead to the non-
acceptability of the final proposal represented by the project. Therefore, the project documents
must as a rule be at least the following:

• A critical historical study on the complex to be restored which identifies all the
transformations that have occurred over time and illustrates them in a specific graph;
• A study of the seismic history of the site; - an accurate plano-altimetric survey of the
complex, including the foundation structures;
• A detailed critical survey that reports the data acquired by crossing them with data
obtainable through the use of diagnostic tools;

97
• A detailed analysis of the loads with the designer identifying all the load-bearing
elements, including the foundations, through which a rational structural scheme is
identified; - a metric and photographic survey of the failures found;
• A description of the constitution of the subsoil and of the stability conditions of the
surrounding area; - a report that identifies the causes and extent of the failures; this report
should indicate, if and to what extent, the failures have damaged the load-bearing
elements of the structure;
• An report on the structural materials present with an assessment of their state of
conservation, supported where possible by experimental investigations;
• The qualitative and quantitative project of the planned interventions, indicating the
reasons that suggest them and the increases in resistance that are presumed to accompany
them;
• In the graphic basis of the project, all the interventions (consolidations, plants, etc.)
which by their nature involve substitutions or alterations of the original material and
surface of the artifact must also be highlighted, in such a way as to make the extent of
transformations consequent to the 'intervention.

It is essential that the testing itself is not limited to examining the so-called technical aspects,
but rather addresses the intervention as a whole.

98
CHAPTER 5.
Seismic, Technical Observations on Parameters, Estimates and Methodology

99
5.1.0 Seismic risk assessment

All the technical conditions developed in different countries of the world, are designed in order
to achieve three main objectives: firstly to avoid losses in human life, secondly to limit as much
as possible the damage to ordinary buildings and thirdly to buildings of special importance to
remain in the operational phase. In this chapter will be made a brief presentation of seismic risk
in Albania and the changes that the latter has had over the years along with all regulations built
to ensure structures from seismic risk.

5.1.1. Seismic risk in Albania

The seismicity of a certain region is determined by the size of earthquakes (magnitude, intensity,
seismic moment, other dynamic parameters) as well as the frequency of their recurrence (period
or frequency of their occurrence). Albania is part of the “alpine-Mediterranean seismic belt,
which includes the contact area between the lithosphere plates of Africa and Eurasia, which
extends from the Azores to the eastern border of the Mediterranean basin. The most active part
is the Aegean Sea and the surrounding region.” In this region (33-43ºV, 18-30ºL), which is
characterized by the fall of an earthquake with Ms ≥ 6.5 with almost annual frequency, are:
Greece, Albania, Montenegro, Macedonia, Southern Bulgaria and Western Turkey.

Albania is characterized by the activity of intense micro-earthquakes (1.0 <M ≤ 3.0), small
earthquakes (3.0 <M ≤ 5.0) and medium (5.0 <M ≤ 7.0) and only rarely by events with large
earthquakes (M> 7.0 ). During the twentieth century, about 7% of the energy of shallow
earthquakes was produced from autochthonous and aloktone5 seismic sources for the territory
of Albania. The activity between the Adria Mountains and the Albanides is the main beneficiary
of the seismic activity.

Figure 12. Map of tectonic faults on the left, tectonic map of Albania on the right (IGJEUM)

100
The “old seismic map of Albania dates back to 1952 as a product of the work done by engineers
and geologists of the Institute of Sciences and the Ministry of Construction of that period. Since
then, the work for the most accurate seismic risk assessment of the land in our country has
continued with numerous publications until now. The seismic zoning map that is still in force
according to the technical design conditions dates back to 1979” (presented in figure.13).

Figure 13. (a) Map of the current design code for seismic zoning of Albania, year 1979, (b) New seismic
map, related to peak ground acceleration PGA recurrence period 95 years, return period 95 years,
probability of exceeding 10%, Summarized and re-worked by the Institute of Geosciences (IGJEUM)

In another perspective the way design codes over the years have taken seismic operations into
account has changed. “Although the use of” "elastic design spectra" for “seismic analysis has
existed in earlier design procedures in our country, the values and parameters have been much
lower compared to today. In figures below are presented in the same coordinate system the
spectra of KTP-N.2-78 (according to the seismic zoning map of 1963), KTP-N.2-1989
(according to the seismic map of 1978) and Eurocode 8, EN 1998-1 (according to the 2004
seismic map, which is not in force). The increase in the values of the spectral accelerations of
101
different periods of the night is” noticeable. “If we compare today's seismic demand (for an area
with ag = 0.25g) with that of 1978 for an area with intensity VIII front, we notice a large increase
in spectral acceleration taken into account for low (stiff) buildings . If we refer to the Tirana
area, this difference can go up to 10 times, as many studies today give ag values up to 0.25g,
while the intensity on the map was” “7-balle“ in 1979 and “6-balle[9]” in map of 1963.

Taking into account the conservative view of the Eurocode for the Balkan area, and the impact
of the November 2019 earthquake, engineers and specialists are drafting and updating the new
map of seismic zoning of Albania.

Figure 14. Comparison of elastic response spectra


based on the seismic requirements of KTP-N.2-78,
KTP-N.2-89 dhe EN 1998-1

5.1.2. Seismic action referring to current studies and methods according to Eurocode

In accordance with the two basic requirements of anti-seismic design, for ordinary buildings,
seismic loading is taken as a function of two main moments or events of the life of an object:

• Design earthquake, for which the structure is calculated and detailed to meet the failure
condition;
• Service earthquake, for which the structure is calculated and detailed to meet the damage
limitation condition;

A design earthquake is an earthquake with a probability of occurrence once in 475 years, or an


earthquake for which there is a 10% probability (probability) in 50 years of overcoming the
level of damage to the failure structure of the structure. A service earthquake is an earthquake
with a return period of once in 95 years, or an earthquake for which there is a 10% probability
(probability) of occurring in 10 years.

9
Balle – unit of measurement for seismic intensity of the area according to the Richter scale in the Albanian
technical code
102
Seismic analysis for DCM[10] and DCH[11] is done with design spectra[12], which are dependent
on the local ground conditions, the maximum ground acceleration obtained from the seismic
maps (Figure.9). They are the same for both the non-demolition claim “and the damage
limitation claim. Horizontal seismic action is described by two orthogonal components (Sdx,
Sdy), considered as independent and given through the same reaction spectrum”.

2 𝑇𝑇 2.5 2
0 ≤ T ≤ TB : Sd(T) = ag * S * [ + ∗ � − �] (Eq. 10)
3 𝑇𝑇𝐵𝐵 𝑞𝑞 3

2.5
TB ≤ T ≤ TC : Sd(T) = ag * S * (Eq. 11)
𝑞𝑞

2.5 𝑇𝑇𝐶𝐶 ∗ 𝑇𝑇𝐷𝐷


TC ≤ T ≤ TD : Sd(T) = { 𝑎𝑎𝑔𝑔 ∗ 𝑆𝑆 ∗ ∗� �
𝑞𝑞 𝑇𝑇
{ ≥ β * ag (Eq. 12)

2.5 𝑇𝑇𝐶𝐶 ∗ 𝑇𝑇𝐷𝐷


TD ≤ T ≤ 4s : Sd(T) = { 𝑎𝑎𝑔𝑔 ∗ 𝑆𝑆 ∗ ∗� �
𝑞𝑞 𝑇𝑇 2
{ ≥ β * ag (Eq. 13)

Sd(T) - design spectrum


T - the period of oscillation of a system with a degree of freedom
ag - The maximum ground acceleration, which also takes into account the safety factor, is taken
from seismic maps.
TB - the lower limit of the period in the constant part of the spectrum
TC - the upper limit of the period in the constant part of the spectrum
TD - the value of the period where the displacement acceleration spectrum, the displacements
are constant
S - factor that takes into account the ground
q - behavioral factor
β - lower limit value of the horizontal projection spectrum

Parameters S, TB, TC, TD are taken in tabular form and are in function of local land conditions.
In EN 1998 Part 1, Section 3.2 more information can be found on how to classify land categories
and the corresponding values of these parameters. In the Table.8 gives the values of the
parameters used to construct the elastic spectrum[13] with 5% quenching traced in Figure.15.

10
DCM - Ductility Class Medium for structural design according to Eurocode
11
DCH - Ductility Class High for structural design according to Eurocode
12
A response spectrum is a jagged plot of peak response of all possible SDOF(single degree of freedom) systems,
and hence is a description of a particular ground motion
13
The elastic spectrum with 5% quenching is expressed is obtained from expressions 3.10-3.13 but by replacing
the behavior factor with 1. More data can be obtained in Section 3.2.2.2 of EN 1998 Part 1
103
Table 8. Elastic spectrum parameters according to EN1998-1 for categories of lines Type 1: A,B,C,D,E
TB TC TD
Spectrum Ground (s) (s) (s)
ag/g type type S

A 1.0 0.15 0.4 2.0


B 1.2 0.15 0.5 2.0
0.22 1 C 1.15 0.20 0.6 2.0
D 1.35 0.20 0.8 2.0
E 1.4 0.15 0.5 2.0

Figure 15. Recommended elastic response spectra according to Eurocode-8

The vertical component of seismic action is given analogously to the horizontal component,
depending on the type of spectrum. The effects of the vertical component should be considered
in the case where the vertical component of the maximum ground acceleration is greater than
0.25g. More about the shape and parameters used to evaluate the vertical component of seismic
action can be found in Section 3.2.2.3 of EN 1998-1.

5.1.3. Seismic loads combination

According to EN 1990, for each of the load schemes, the design value of the actions and forces
(Ed) is determined by the combination of those loads that are considered to occur at the same
time. Thus for permanent and temporary loads we have (the first combination of loads):

Ed = E { γG.j Gkj; γQ.l, Qk.l.; γQ.j. ψ0.j Qk.j. } j≥1; i≥1 (Eq. 14)

Ed - the value of the design foci


Gk, j - permanent loads
104
Qk,1 - temporary predominant load
Qk, j - temporary loads
AEd - seismic load
γG - partial coefficient of permanent loads
γQ - partial coefficient of temporary loads
ψ0 - temporary load combination factor for the first load combination
ψ2 - temporary load combination factor for seismic load combination

5.2. Two significant Earthquakes that have influenced structures and architecture in
Albania, to be considered for the study

“Earthquake of April 15, 1979”, area between the city of Shkodra and Ulcinj

One of the most significant and “damaging seismic events in the region of Albania was the
strong earthquake of April 15, 1979. Among various engineering works in Albania, the
earthquake also hit new buildings with brick masonry supporting structure, or of reinforced
concrete built in accordance with the design conditions of the time (KTP-1963). This includes
5-storey buildings with unreinforced masonry Structures, which according to KTP-1963" should
not show” seismic problems.

One of the most affected cities was Shkodra, where in a considerable number of typical masonry
buildings, typical diagonal damages and cracks were formed, but also masonry out of plan.
Especially the two and three-story buildings, also the private villas in the region suffered corner
damage and “roof damage. These effects have appeared on the upper floors where the wall
displacements are greater while the pressure stress that could serve as opposition is at a lower
value”.

5.2.1 Analysis and assessments on strong seismic events and the Earthquake of November
26, 2021 in Albania

The diagram below shows a summary of parameters and data on the accelerations of the 5
strongest seismic events captured by the Institute of Seismology in Albania, including the
moderate seismic event of 2019. In the left part of the diagrams are given evaluation parameters
of a seismic event, specifically "earthquake acceleration, quake velocity, ground displacement,
arias intensity and housner intensity". While the diagram summarized on the right contains in
the form of diagrams the comparisons of the 5 strongest seismic events recorded in the Albanian
territory since 1978. Above on the right is the diagram "amplitude-frequency oscillation", while
on the bottom right, is the summary of elastic-spectrum process of these seismic events,
specifically "spectral acceleration-periods". This summary gives us a more complete
information of the seismic risks of the Albanian land and the risk of these buildings for the
future.

105
Figure 16. Summary diagram developed by the institute of seismology, after the seismic events of 2019
(Source: IGJEUM)

Regarding the 6.4 Mw earthquake that occurred near the Durrës area, which is positioned near
the west coast of Albania in the Adriatic Sea, can be considered small compared to the design
earthquake parameters, which is currently used in technical design conditions of Albania,
however caused a quantity large damage to buildings, structural damage, collapse and non-
reparable structural damages, as well as damage to non-structural elements, mainly partition
walls and perimeter "infills". Fifty-one people died, about 3,000 were injured and between 5,000
and 14,000 people were left homeless after this seismic event.

5.2.2 Details of the seismic event of November 26, 2019 in Albania

The strong earthquake with a magnitude of 6.4 Mw in Albania, occurred exactly two months
after the other two earthquakes considered moderate. The quake event started at 03:56 in the
morning of November 26, 2019, emphasizing in addition to the damages mentioned above,
causing “severely damaged over two thousand buildings in the cities of Durres, Tirana and the
surrounding area. The epicenter was reported below the Adriatic coast, 7 km north of the coastal
city of Durres and about 30 km west of Tirana, the capital of Albania.” (Figure.17)

106
Figure 17. Quake M6.4 affected area and the lines distribution of shakes intensity (Charleson & Vesho,
2020)

Based on archival research and review of a group of studies in this field, detailed information
was found on the intensity of earthquakes, the geology of the basement and the effects of soft
soil ground in the affected region of Durres-Tirana, also, the types of building structures and the
extent of geotechnical liquefaction (Lekkas 2019). The authors of the seismic engineering field
have also identified that Tirana and Durres are located in a seismically active area, near the
tectonic fault of the Adriatic and above the continental fault, which passes between Durres-
Tirana “and has been almost completely destroyed by earthquakes, at least seven times before.
in 177 BC, years 334 or 345 AC, 506, 1273, 1279, 1869 and 1870. Also, as mentioned above, a
moderate event "earthquake with Mw 5.6", in the same vicinity on September 21, 2019,
damaged about 500 buildings in the Tirana-Durres area.”

This study had the opportunity to gather useful data on these events, as it went through these
events a good phase of field research. “Another report, also of a preliminary nature, contains
information on the history of local building codes and construction and design approaches, the
occurrence of aftershocks in a given period and the seismic performance of building types,
including schools, hospitals, cultural heritage buildings and civil houses” (Alam 2019).

Regarding “the characteristics of earthquake oscillations, so far only two response spectra are
available (Figure below), (Geo.edu.al, 2020). They were taken from two accelerations recorded
in Tirana, 30 km from Durrës and then processed and summarized in a diagram. Unfortunately,
an accelerometer in Durrës stopped recording after 15 seconds of oscillation, after problems
with electricity, but the 'reconstructed' spectra are fortunately ready to be analyzed, and to be
put to use seismic simulations. Due to its smaller epicenter distance and greater amplification
from the soft soils of this area, the Durrës spectrum exhibits higher spectral accelerations and
over a longer period interval. The duration of the strong shakes in Tirana was approximately 40
seconds, about four times longer than the most considered moderate earthquake” with Mw 5.6
of September 2019.
107
Figure 18. Two response spectra from Tirana re-worked and compared to the current design code elastic
spectrum (Charleson & Vesho, 2020)

5% Damped Spectral Acceleration


0.7

Frequency Domain Spectral


0.6
5% Damped Spectral Acceleration (g)

Acceleration (g)

0.5
Duhamel Integral Spectral
Acceleration (g)
0.4
Duhamel Integral (with
0.3 timestep correction) Spectral
Acceleration (g)
0.2
Newmark Beta Method Spectral
Acceleration (g)
0.1
Newmark Beta Method (with
0 timestep correction) Spectral
0.01 0.1 1 10 Acceleration (g)
Period (sec)

Figure 19. Data related to M.6.4 Durres earthquake spectra, 5% damped spectral acceleration – period
(Source: IGJEUM/ Graphically processed by author)

108
Fourier Amplitude
1

100 10 1 0.1 0.01 0.001


0.1

Fourier Amplitude (g-sec)


0.01

0.001

0.0001

0.00001

0.000001

0.0000001
Frequency (Hz)

Figure 20. Data related to M.6.4 Durres earthquake fourier amlitude based on frequency and amplitude
(Source: IGJEUM)

Acceleration
0.2

0.15

0.1

0.05
Acceleration (g)

-0.05

-0.1

-0.15

-0.2

-0.25
0 20 40 60 80
Time (s)

Figure 21. Data related to M.6.4 Durres earthquake acceleration recorded (Source: IGJEUM)

109
Velocity Displacement
1.5 0.5

0.4
1
0.3

Displacement (ft)
Velocity (ft/s)

0.5 0.2

0.1
0 0

-0.1
-0.5
0 20 40 60 80 -0.2
0 20 40 60 80
-1
Time (s) Time (s)

Figure 22. Data related to M.6.4 Durres earthquake Velocity and Displacement recorded (IGJEUM)

Arias intensity Housner Intensity


1.8
5
1.6 4.5
Housner Intensity (ft/s)

1.4 4
Arias intensity (ft/s)

1.2 3.5
1 3
2.5
0.8 2
0.6 1.5
0.4 1
0.2 0.5
0
0
0 20 40 60 80
0 50 100
Time (s)
Time (s)
Figure 23. Data related to M.6.4 Durres earthquake Velocity and Displacement recorded (IGJEUM)

5.3.0 Theoretical interpretations on the impact of earthquakes and seismic risk on


masonry structures, regarding the practice of design codes in Albania

An earthquake is a vibration of the basement under foundation, which conveys these to the
object and causes displacement, velocity and acceleration in the object under consideration.

Masonry buildings occupy a significant place in Albanian construction. They were built in
different time periods from 1900-1990. These typologies, designed before the 1990s constitute
most of the residential buildings, which are designed in accordance with the technical design
codes [KTP ‐ 63, 1963, KTP ‐ 78, 1978; KTP ‐ 89, 1989], and after the 1990s consist of 2 or 3
floors, which were built mainly by private investors for residential purposes. Also these
typologies of buildings are used as institutions, historic objects or businesses. Most of these
110
structures are built based on traditional construction techniques, codes of neighboring countries
“Italian, Greek, also the Russian code”, some of them without genuine engineering projects
based on design codes.

5.3.1 Seismic risks affecting the safety of masonry buildings

Seismic “activity in countries like Albania is one of the main risks for buildings”, this was shown
also by the earthquake of November 2019. “It is proven that seismic events are the main factor
that affects the dimensioning of structural elements sections, therefore should be given an
importance of great design and retrofit of these structures. Seismicity is represented by the
elastic design spectrum, that according to the Albanian standard KTP ‐ N2‐89, which” is still in
force, many structures with masonry are designed. “To build these spectra diagrams, such
parameters have been used to represent the seismic risk in most of the territory of Albania”.

In the “current post-earthquake situation of 2019, the main structural damages of this typology
are from seismic horizontal loads. For a structure to resist this force, it is necessary to have
ductile behavior to absorb and extinguish seismic energy. In reinforced concrete buildings this
ductility is gained by steel bars. Related to masonry structures we do not have proper ductile
elements, so they are more vulnerable at this kind of seismic risk. They are capable of
withstanding low, medium and moderate earthquakes due to the great stiffness of the large
working section. Also their global ductility is ensured by the gradual detachment near the mortar
joints with the bricks, in the most stressed areas.”

The “old Albanian design codes do not provide sufficient measures for the seismic safety of these
buildings. This situation becomes even more serious when we consider the degradation over the
years, additions, functional adaptations and structural interventions. For these reasons these
structures do not agree the utilization requirements and the new Design Codes. It is about
"Eurocodes", specifically part-6, which reflects a high level of knowledge in the field of
Structural Engineering with masonry design, or Eurocode part-8 which deals specifically with
the part of seismic engineering, retrofit interventions and relevant parameters.”

Seismic “design of structures according to Eurocodes, summarized in Eurocode 8 is more


advanced compared to the code based on the Technical Design Conditions (KTP) of Albania.
The last update of KTPs was made in 1989 with the approval of KTP ‐ N.2‐89 (Academy of
Sciences, Ministry of Construction, 1989). On the other hand, many existing buildings were
realized before this year, based on even older design codes, considering also uses of Russian
and Italian codes. Structures designed with previous codes have suffered severe damage due to
insufficient capacity to withstand seismic load and limited ductility”. In the post-2019 period,
the situation is being analyzed and work is being done through the associations of engineers to
include the procedures of seismic evaluation of the existing structures and their rehabilitation in
the Design Code, moreover, some aspects of the more advanced codes are being analyzed like
the "Performance levels of the buildings according to ATC-40[14], FEMA-440[15] and FEMA-
356[16]".

14
Seismic evaluation and retrofit of concrete buildings
15
Improvement of Nonlinear Static Seismic Analysis Procedures
16
Prestandard and. Commentary for the Seismic Rehabilitation of. Buildings
111
One of the most important challenges for designers remains the assessment of the seismic
capacity of existing buildings, seismic performance and the assessment of their response under
a strong ground motion.

Consideration of “nonlinear procedures in country codes, such as "ATC ‐ 40, 1996; FEMA ‐ 356,
2000; FEMA ‐ 440, 2005; N2-Method, 1996[17]; Eurocode 8.3[18]", which have been widely
developed over the decades last, are the approaches to achieve this target. Using nonlinear
analysis, it is possible to predict the capacity of the structure more accurately and realistically
through the shape of the capacity curve. These results should be used to notify the competent
authorities of the risk of a strong earthquake expected” in the future.

5.3.2 Seismic events and movements of the basement

Seismic force is caused by the movement of the ground due to the earthquake, which is a
movement in all directions but in calculation this movement, and consequently the seismic force,
is taken in three directions: two horizontal and one vertical. In this way, for each element of a
building structure, the calculated value of the factor that arises due to the action of the
earthquake, the maximum value is taken from them:

Seq = Seq, x + λSeq, y + λSeq,z


Seq = λSeq,x + Seq, y + λSeq,z
Seq = λSeq,x + λSeq, y + Seq,z (Eq. 15)

Seq,x, Seq,y - are the values of the factor arising from the calculation of the construction separately
to the horizontal components of the ground;
Seq,z - the value of the factor resulting from the calculation of the seismic vertical component.

5.3.3 Combination of loads

Seismic loads are treated as separate loads and are included in the calculation of structures and
foundations of engineering projects according to the specific combination of loads. In this study
the load coefficients considered under consideration based on the design code are given in
Table.9:

Table 9. Combination values related to load types


Load types Specific combination coefficient values
Seismic loads 1.0
Dead loads 0.9
Live loads with long action 0.8
Temporary loads with short action 0.4

In the design and calculation phase of structures against seismic actions, the following
parameters is not taken into account:

17
A relatively simple nonlinear method for the seismic performance evaluation of structures
18
Assessment and retrofitting of buildings
112
• Wind loads;
• Climatic temperature estimates;
• Dynamic actions caused by specific machinery or machines;
• Braking forces caused by the movement of cranes;
• Horizontal loads caused by the movement of suspended masses in the cable;
• Reductions (eruptions) of foundations.

We can emphasize that these parameters above can be analyzed through various unfavorable
combinations suggested by Eurocode, technical design code of Albania or Italian code.

5.4. Calculation methods

The design and calculation of building structures and engineering projects against seismic
actions is performed through:
• Seismic modal analysis with the response spectrum method (seismic loads are accepted
as equivalent static loads and applied at the site of concentrated masses) [19];
• Use of direct dynamic analysis (This is done through the integration of equations of
motion of the structure), choosing computational accelerograms, based on studies of
seismicity of the construction site and its geomorphological and geotechnical
features[20].

These calculation methods should be interpreted and analyzed in the Albanian design context in
the period 1920-1940. Theoretically, a general research should be done on the beginning of anti-
seismic design and construction technology in Albania. We can distinguish three periods of anti-
seismic projections in Albania:
• Before 1963 when seismic requirements were very low or absent at all;
• Period from 1963 to 1990 with low seismic requirements;
• Period after 1990 where seismic requirements are based on KTP-N.2-1989, which based
on what we said above, despite being more developed than the previous codes, again
they can be considered insufficient for the level of risk seismic in our country.

So, we can say that at the time these buildings were designed and implemented, in Albania they
were designed taking not into account advanced seismic aspects or simply not based on code.
But normally they have withstood the test of time and have successfully passed many strong
and moderate seismic events and happenings. This leads us to analyze that Italian designers have
used good principles of anti-seismic design, carefully studying the configuration of buildings,
regularity in plan and height, as well as equal distribution of masses.

5.4.1 The equivalent frame Method

For newly built structures, or for structures where the floor strips are not very rigid, an "elastic"
check must be carried out, assimilating the wall to a framed system. The method involves a

19
Modal analysis is the study of the dynamic parameters of systems in the frequency domain aspect.
20
The direct steady-state dynamic analysis procedure can consider a perturbation procedure, where the solution is
obtained by linearization about the current base state. For the calculation of the base the structure may exhibit
material properties and geometrical nonlinear behavior as well as contact non-linearities.
113
macro-element modeling of masonry buildings: a flat model if we consider only one wall, three-
dimensional if we consider the entire building.

Figure 24. Equivalent frame method model and elements

In this numerical-physical representation the structure is schematized as an equivalent frame,


consisting of:
• vertical axis elements: ordinary or reinforced masonry panels, pillars or partitions in
reinforced concrete;
• elements with horizontal axis: coupling beams, floor strips, reinforced concrete curbs.
This schematization is acceptable if the geometry of the walls and the distribution of the
openings presented there are characterized by a certain regularity, in particular as regards the
alignment of the openings. Each frame element, with vertical or horizontal development, can be
represented as a "one-dimensional" element by means of its main barycentric axis and is
delimited by nodes usually positioned at the intersections of this with the barycentric axes of
the elements to which that element is connected. The introduction of infinitely rigid sections
(rigid offsets), of suitable dimensions at the ends of the elements (columns, curb and / or strips),
allows to model the reduced deformability of the masonry fields delimited by the openings in
the wall (structural nodes).

114
Figure 25. Experimental model with openings (Dolce, 1989/ Graphically processed by author)
The height of the deformable part, or effective height of the Heff, must be defined in such a way
as to roughly take into account the deformability of the masonry in the knot areas; it can be
evaluated on the basis of the following relationship, as a function of the geometric dimensions
of the panel and of the openings (Dolce, 1989):
1∗(H−h`)
Heff = ℎ + ≤H (Eq. 16)
3∗h`

L - is the length of the panel;


H - Net length of the height of the cross;
h' - is a conventional height parameter defined on the basis of the cases shown in the figure

Figure 26. The panel under the action of static actions N,T,M

Once the elastic analysis has been carried out on the spatial framed system of the structure,
subject to a distribution of horizontal forces (seismic or wind), each masonry pillar is subject to
N, M, T actions. In addition to the checks on the masonry walls, the floor strips must also be
checked.

115
5.4.2 Masonry calculation models and typologies

It is a well-known fact that structures with structural masonry were used and applied tens of
centuries ago, the problem of mathematical modeling is still a major problem even today.
Whereas if we do a research on materials such as concrete, steel and reinforcement which have
been used in construction for only a century, there are formulas and models which with high
precision calculate and predict the physico-mechanical behavior of reinforced concrete or steel
structures.

The main problems in the configuration of the masonry model, are in the great variety of filler
elements of the masonry, mortar and brand of mortar which is used, as well as the used
construction techniques, as well as the technological level of production and construction.
Therefore, the bearing capacity of the masonry depends on the qualities of the element / stone,
mortar and the cooperation of these two elements.

Even the structure of masonry as a whole, as the assembly of elements in the individual aspect,
presents a non-homogeneous and anisotropic structure, which makes it difficult to calculate and
of course the conception of the physical model.

The two general modeling approaches: “micro-modeling and macro-modeling”

In the scientific literature, the problem of modeling masonry buildings is faced by following
two different approaches, known as micro-modeling and macro-modeling.

In micro-modeling, a description is made of the individual materials making up the masonry,


blocks and mortar joints, using different constitutive models. Usually this approach is pursued
using the finite element method. By its nature, this technique is able to describe heterogeneous
structural systems with complex geometry, but it requires such a high number of degrees of
freedom in defining the model that micro-modeling is practically inapplicable in the study of
real structural systems. Its use is almost exclusively limited to the validation of simplified
modeling techniques.

In macro-modeling, it is not necessary to describe the constitutive bonds of the single component
materials but macro-elements are used that are able to grasp the global behavior of entire
structural portions such as masonry walls, lintels and node panels. The single macro-element
must therefore describe all the possible inelastic mechanisms typical of masonry walls making
use of a few constitutive parameters and a reduced number of degrees of freedom. This approach
makes it possible to drastically simplify the description of buildings and to contain the
calculation times necessary for the structural analysis. On the other hand, however, it presents
the difficulty of being able to formulate an analytical model capable of taking into account all
aspects of the non-linear behavior of an entire portion of a masonry building through a single
structural element.

Mainly mathematical and numerical models are divided into two groups:

• "Macro-model" – models where the wall is considered as homogeneous


• “Micro-model” – are those models, where the wall panel is examined as a combination
of elements (brick/stone), mortar, as well as the adhesion between them. The second
116
method is more accurate but requires software as well as powerful hardware, which are
greatly complicated and loaded with increasing the size of the structure and this happens
after the mesh configuration.

Figure 27. Type-a & b of computational models of micro-modeling and macro-modeling

Figure 28. Type-c & d of computational models of micro-modeling and macro-modeling

Despite this, the macrostructure-based models, with the approximations made, show acceptable
and logical results for many cases in engineering practice.

Necessary parameters for macrostructure are obtained either on the basis of experimental results
or even by micromodeling of a relative area.
Types of general models to be adopted in softwares for masonry structures. The possible models
are as follows below:

• Shell: the masonry structural elements are discretized using the finite element technique
and modeled as elastic two-dimensional shells. This modeling can only be used to
perform elastic analyzes while obviously it is not suitable for conducting push-over
analyzes;
117
• Members: the structural system is modeled using the equivalent frame SAM method[21].
A non-linear structural model is thus obtained to be used for push-over analyzes;
• Macro-elements: the entire structural masonry system is initially discretized through a
mesh of the type used in the finite element method. Each single element of the mesh is
then modeled as a macro-element. A non-linear model of the structural system is thus
obtained on which to conduct push-over analyzes.

5.4.3 The definition of “Resistant mechanism” of a shear (or bracing) wall

The model presented and explained above, considered with equivalent elements can be further
elaborated, giving the way of work of each element in particular. The following are defined:

• strut panels between two windows, which work floor by floor in parallel;
• floor strip/shape - the continuous strip between the upper and lower windows of each
floor, icluding all horizontal elements.

Figure 29. The model that represent the resistant mechanism of shear

If the shear wall has a sufficiently rigid floor strip, such as to guarantee the parallel functioning
of the masonry elements, it is possible to identify at each level a resistant mechanism in which
the elementary cell is the inter-floor. In these hypotheses, analyzing the single "cell" it can
generally be “observed that the collapse occurs due to the rupture of the Strutt panel” with a
mechanism characterized by the formation of plastic hinges in them.

21
The Successive Approximation Model (SAM) is a simplified Model designed specifically to elicit feedback and
build different working and calculating models
118
Figure 30. The stages that the resistance model goes through until deformation, and how it is conceived
in static aspects

In this case, each Strutt panel is subjected to a stress state (shear stress) comparable to that
reproduced in a diagonal test, therefore the criteria seen above can be applied. The collapse of
the wall is reached when the first Strutt wall is broken.

5.4.4 Technical behaviors of unreinforced masonry structures

Unreinforced masonry structures normally consist on massive foundations, unreinforced walls,


orthogonal piers and timber slab or thin concrete slab, working as a diaphragms, connected to
walls with structural diaphragm. Unreinforced masonry walls are typically stiff structural
elements, also can be categorized at the in plane and out of plane panels depending on the
directions of earthquake motion events regarding to the plane axis of the walls. Wall panels
oriented parallel to the motion direction of the earthquakes are known in plane panels, and panels
perpendicular to in plane walls are defined as the out of plane walls.
Unreinforced masonry has been shown during the time to perform poorly behind the earthquakes
events. There are some number of common details and technical aspects of unreinforced
masonry constructions that have been identified as the deficient ones. The common mechanisms
of collapse or failure are mainly sub-divided into two categories as below:
• In plane panels – Masonry wall panels subjected to in plane horizontal kind of loads may
fail in one, two or three different ways. First by sliding horizontally, second in flexure,
or third in shear stress. The mode of failure is influenced by many factors such as wall
ratio aspects, axial compressions stress different levels, wall boundary conditions,
physico-mechanical parameters and the strength properties of the materials used in the

119
wall panel construction. These types of failure are shown diagrammatically in the figure
below.

Figure 31. Failure shapes regarding in plane loaded masonry panel, first panel in flexure and second
panel in rocking

Figure 32. Failure shapes regarding in plane loaded panel, first in Sliding & second in diagonal shear
stress

• Out of plane mechanisms – These kind of mechanisms occur mainly with out of plane
kinematics of one or more wall panels of the selected unreinforced masonry structure
causing the loss of its own original structural configuration at the expense of large
seismic events excitation. The arising of out of plane failure or collapse mechanisms,
mainly resulted “according to bad connection between the wall panels of the façade and
the orthogonal panels”.

Based on the failure or collapse mechanism of masonry walls, the common failure modes of
unreinforced masonry structures ca be summarized as follow below:

• Story shear mechanisms related to upper storeys;


• Story shear mechanisms related to lower storeys;
• Whole wall panel overturning;
• Partially wall panel overturning;
• Gable wall panel overturning;

120
• Vertically instability of wall panel.

The story shear-mechanisms related to upper storeys – This kind of failure mechanisms as
shown in the figure below is normally caused according to variations in the resistance system at
the upper floors, for example variations in the wall thickness or the presence of poor quality
masonry panel. This kind of failure mechanisms is also caused by the presence of heavy rigid
roofs.

Story shear mechanisms related to lower storeys – This kind of failure mechanism that is showed
also in the figure below with diagonal shear cracks of in plane panels positioned at the lower
storeys. This is mainly caused by the small resistance area in 1 or 2 directions for example for
high percentage of openings in the façade or small thickness of the walls panel located at lower
storeys of the structure.

The whole wall panel overturning – This kind of failure mechanisms is mainly caused by lack
of connections between orthogonal walls panel or ties elements or ring beams as will be shown
at the figure below. This is also caused an resulted by large distance between walls panel and
the thrusting roof panel at the top accompanied with lack of connection between wall and roof.

Partial wall overturning – This kind of failure mechanisms is mainly caused by the following
“reasons large distance between panels”, thrusting roof and lack of connections between wall
and roof panel, also high percentage of the openings creating potential regions and areas for
cracks and deformations on the panel.

(a). (b). (c). (d).

Figure 33. (a) Failure mechanism of Storey shear located on Upper storey, (b) Failure mechaninsm
related to Storey shear, (c) the failure mechanisms of whole wall overturning, (d) the failure mechanisms
related to partial wall overturning.

The Gable wall overturning type – This kind of failure mechanisms consists on overturning of
the gable wall as shown in the figure below and is generally caused by the presence of heavy
roofs with pushing in transversal elements into the gable walls panel. Another reason could be
in good connections between the orthogonal walls panel, but the lack of connections or the ties
element or the ring beams of the building in the top.

The vertical instability of wall panel - This kind of mechanism is mainly caused by the presence
of ring beams in breach of the masonry to the double wall thickness as shown in Fig. below.
Also the contributing factors could be in very poor quality of masonry panel and presence of
intermediate heavy floors with very poor embedment to the wall panels.
121
According to studies is reported that the out of plane mechanisms (complete failure and partial
failure wall panel overturning’s, gable wall overturning’s failure, vertical instability failure) can
happen more frequently related to the high level of global damage aspects of the structures than
the in plane collapse mechanisms including storey shears stress. Also, better vulnerability
assessments proper cares and in site researches are needed for out of plane analyzing and
strengthening of unreinforced masonry walls.

Figure 34. Gable wall overturning failure mechanisms and the Vertical instability failure mechanisms
of the wall.

5.4.5 Theoretical Interpretations on Pushover Nonlinear static procedures

After creating the computational model in the software, we perform nonlinear static analysis
(Pushover). Although the Pushover and Time History analysis is based on this method, the
purpose of this Restoration topic is limited to in-depth aspects of seismic engineering and does
not attempt to describe it theoretically, and will therefore be limited to a few general aspects.
like below:

Pushover analysis of a structure, is a nonlinear static analysis under the constant action of
vertical loads, and almost static horizontal loads that gradually increase until the destruction of
the structure. The calculation model includes not only the detailing of the dimensions and
properties of the structural and non-structural elements as in the paragraph above, but also
defines the permanent and temporary vertical loads as well as the almost static horizontal load.
The latter, which represents seismic action, increases gradually and is taken concentrated at
floor level. From this analysis, we obtain the Pushover curve which expresses the dependence
of the shear force on the structure, with the displacement at its apex. This gives us the
opportunity to judge the load for which the collapse occurs as well as the level of ductility
possessed by the structure.

5.4.6 Determining the performance point of the structure related to nonlinear procedure

To interpret the results obtained from non-linear pushover analyzes, the Capacity Spectrum
Method is commonly used. This method uses the intersection of the global force-based
122
displacement curve at the top, as well as the response spectrum, representing the spectral
demand for earthquakes, to estimate the maximum displacement demand of the structure or to
give its performance point.

After obtaining the capacity curve for the multi-degree system from nonlinear static analysis,
the procedure followed to determine the performance point[22] for a seismic demand level is
somewhat different from the conventional methods widely known in the literature and involves
the following steps:

• Transformation of the Pushover curve into ADRS format, i.e. obtaining the capacity
curve;
• Idealization of the capacity curve;
• Discretizing the idealized capacity curve and defining a suitable system with a degree of
freedom for inelastic spectrum analysis;
• Inelastic spectrum calculation;
• Determining the point of performance.

22
The Performance Point, which represents the state of maximum inelastic capacity of the structure, is found
through the cross point of the Capacity Spectrum and Demand Spectrum for a given damping ratio.
123
CHAPTER 6.
Case Studies – Experimental Part

124
6.1. CASE 1 - General overview of the Municipality of Tirana building, part of Cultural
Heritage. Architectural identification, survey process and structural evaluation

The Skanderbeg square complex consisted of three pairs of buildings, designed between 1929
and 1932 by the Roman rooftop architect Florestano Di Fausto & Gherardo Bosio. Initially, the
project for the square “included four other buildings on the north side, forming a circular exedra,
however only one was built, the old Town Hall, which was demolished in the 1960s to make
way for the National Museum. Next to the Ethem Beu mosque stood the Ministry of Economy
and Education, opposite the Ministry of Foreign Affairs” and Presidency.

Figure 35. Municipality of Tirana original drawings of F. Di Fausto 29’ project-idea (Source: AQTN)

These twin buildings had a “C” shape geometry with the entrances at an angle, connected by
circular exedras. All the lift systems were positioned on the diagonal axes passing through the
entrances, preserving a perfect symmetry of the plan. “The load-bearing structure was of a mixed
type: reinforced concrete frame and load-bearing masonry, a constructive solution that allowed
for large rooms with free light, such as the ballroom on the rear side of the square, and at the
same time to preserve the characters of the typical massiveness of the masonry, present on the
entire external curtain of the building. The main facade of the wall surface is very rich, the
numerous layers of the wall surface treated with different materials (stone, brick and plaster)
accentuate the vertical sections of the façade, marked by stone columns between, which the
openings are framed”.

125
It's “a formal repertoire that favors the wall surfaces on which loggias are recessed or from which
volumes project, in which the compositional operations focus on the theme of the complex
rhythm of the façade”.

The buildings that housed the Ministry of Public Works and the Ministry of the Interior closed
off Skanderbeg square, on the south side, inclined at 45 ° with respect to the monumental axis,
these buildings served as scenographic backdrops to frame the monumental axis that was lost
on the horizon. The buildings had many decorative details, stylish arch-beams around the
windows and valuable architectural sculptures on their facades. Normally giving the Italian
architectural style of the period 1919-1938.

Figure 36. On the left, an old archive photo which shows the works on the construction of the Di Fausto
building near Skenderbej Square, on the right an identification scheme of cultural heritage objects near
the center.

Even this pair of twin buildings, like the whole complex of the square, were designed by
Florestano Di Fausto between 1929 and 1932 and built by the Staccioli company, with which
the architect had already worked in the Dodecanese. The architectural plastic of the façade is
particularly articulated, on the bottom plane of the masonry the different scores, progressively
projecting, stand out, framing the windows, the moldings that frame squares that could also have
been enriched by pictorial cycles, the contained “overhangs of the balconies, the shelves in
cement stone, the teeth and the different profiles of the frames, but also the ashlars of the base
part with respect to the joints and so on. In the full-bodied tones of the plasters, the light creates
those chiaroscuro effects that distinguish the designs of Italian architects from those of Northern
Europe. The buildings were perfectly symmetrical, with the monumental entrance on the central
axis and then a longitudinal body concluded with a 45 ° rotation” of the last part, in such a way
as to manage the funnel of the square in connection with the other buildings.

These two buildings have also undergone changes over the years, both of a distributive type and
of elevation and expansion, in particular the addition of a floor has made the central tripartite
rooftop disappear.
126
Figure 37. An identification diagram of cultural heritage objects near the center combined by photo
collage for each monument

It should be mentioned and underlined that the structural intervention of 2004 and the addition
in the back of the structure, may be the one that has left the most traces in the body of the
building designed by Di Fausto. To show in more detail graphically and geometrically, what the
transition, or transformation, was like before and after this period, at the end, in the study
annexes there is a timeline with all the drawing sheets of the project step by step summarized.

6.1.1 Collection of data

The knowledge of the building for which an investigation and analysis is planned is the first
operation to be performed.

The immediately visible and detectable information are those of a geometric nature and those
relating to the surfaces. To these must be added the historical and documentary information,
including those transmitted orally, and, deepening more and more, the knowledge of materials
and their physico-mechanical parameters, textures, masonry equipment, mortar parameters,
historical evolution and the state of conservation, just to name a few aspects. All these data
subsequently require a contextual and coordinated examination, so that the hypotheses for the
research and analysis are the result of an organic operation that does not leave out any of the
available data, not even the apparently most irrelevant ones.

127
6.1.2. Architectural survey process and monitoring on-site

The research on-site was organized during the academic year 2020-2021, led by the academic
staff of the Cultural Heritage Restoration course, also included students of Architecture and
Civil Engineering, fourth year, as a cooperation between Polis University, institute of cultural
heritage and PhD program. The field work consisted of comparing the planimetry of the archival
project with the real building of the Tirana Municipality today. The object was photographed
with a drone from different angles and positions, to have a set of orthogonal photos for the
photogrammetry process. Looking very carefully at the differences found between the
current building today and the archival project according to the idea of Florestano di Fausto,
such as a different number of doors and windows, the position of the decorative elements on
the façade, changes in geometric shapes, changes in the positions of the interior walls,
etc. Laser measurements were performed to give the proper dimensions that the building has
today. In this report from the research on-site, the objects are presented and compared, coming
up with some findings, such as noting the geometric differences in plan and height, between
the real project and the cuts taken in the archives that we had available, some detailed
photos , and some interesting issues to be analyzed were noticed.

Figure 38. Basement floor according to F. Di Fausto idea, 1929 project-idea (Source: AQTN)

Figure 39. Ground floor according to F. Di Fausto idea, 1929 project-idea (Source: AQTN)
128
(a) (b) (c)
Figure 40. (a), (b) Section cut and the south façade behind, from the “F. De Fausto projcet idea 1929”,
(c) Section cut from the implementing project 1941 (Source: AQTN)

Figure 41. Architectural survey of two typical windos on the main façade, digitalization process

Figure 42. Architectural survey of the two main doors of the main façade, digitalization process

129
Figure 43. Municipality of Tirana analytics and architectural diagrams (credits D. Gjuraj & A. Kapaj)

130
Figure 44. Summary and collage of photos from outside and inside the building, part of the survey
process (credits: D. Gjuraj & A. Kapaj)

131
(a)

(b) (c)

(d)

Figure 45. The process of architectural surveying, (a) main façade west side; (b) south side façade; (c)
north side façade; (d) behind façade view, positioned in addition

132
Figure 46. The process of architectural surveying, monitoring and analysis on facade maintenance issues
(credits D. Gjuraj & A. Kapaj)

133
Figure 47 Parts of architectural survey process, all plans, main section cut, raports between two different
typologies of structures in plan, foundation plan combined by architectural details analysed

134
6.1.3 Structural evaluation, methodology and Analysis

At the structural and “architectural scale, the study provided a systematic collection of relevant
data on the building techniques, brick materials and finish, state of conservation and seismic
restoration. Interest was focused on the four main technical elements of these buildings, as walls,
ground floor slab, wooden doors” and windows. Meanwhile, in 2001 a partial restoration of the
building was made, also a new structure was added in the back of the existing building. The
typology of the new building is RC frame systems [23] and was connected to the old building on
the joints of floor dividers, exactly with the slabs. Between the two objects there is a narrow
space to allow the structures to work separately.

Figure 48. Municipality of Tirana, Updated ground floor plan after restoration (Dhimgjini, Katundi, &
Paci, March, 2001)

The seismic risk class depends on one parameter: which takes into account “the damage and
refers to the cost of reconstruction of the building; taking into account the achievement of the
limit state for safeguarding life” (life safety level) [24].

6.1.4 Use of F.E.M. interpretation of the crack Pattern and their distribution
The assessment of seismic performance of URM buildings [25] requires the identification of the
collapse mechanisms and masonry local damages step by step activated by the synthetic
earthquake (elastic demand spectrum) [26]. Referring the current practice in our region has been
taken into account only three first modes of failure, by studying the capacity curves of certain
structural typologies, to get the right strategy for strengthening and updating the structure.
The modelling of the structure behaviour and its safety assessment by mesh process and f.e.m 27
model (finite-elements-method), can highly benefit of the ETABS, which enables us to create

23
Reinforced concrete (RC) frames consist of horizontal elements (beams) and vertical elements (columns)
connected by rigid joints.
24
Second level mostly used for designing civil structures based on seismic performance levels [Eurocode 8]
25
Unreinforced masonry building typology, without reinforced concrete frames.
26
Merging a number of strong short-period ground motions and long-period ground motions. From the merging of
these accelerograms, an elastic specter is deduced.
27
F.e.m. - The finite element method is an important method for numerically solving differential equations arising
in seismic engineering and mathematical/numerical modeling.
135
layered walls, considering the non-linearity of each layer that represent materials data. (Vesho,
Guri, & Marku, 2019)
The most important step is transformation and conversion of panels in piers and spandrels
labeling [28]. The vertical panels working in compression are converted in the Piers (frame
elements that work in compression), while the horizontal panels under the openings below are
converted to the spandrels (beams in bending) (Pitilakis, Crowley, & Kaynia, 2014). The
parameters followed for the seismic analysis are taken referring to the Eurocode. (Eurocode 8,
Part.1, 2004)
Investigation procedures: In general the necessity of monitoring and investigating “the building
integrity or the load carrying capacity of a unreinforced masonry building arises for several
reasons including: assessment of the safety and stability of the structure before or after a seismic
event, extension of the building and also the change of use, assessment of the effectiveness of
repair innovative techniques applied to structures or different materials, and long-term
monitoring of material parameters and structural performance.” (Binda, Saisi, & Tiraboschi,
June 2000)

6.1.5. Structural evaluation and seismic performance of the building


Below is presented the object to be analyzed, the municipality of Tirana building after
interventions. The constructive project and technical specifications for this building are taken
from the technical archives of Tirana. While the data regarding the addition of the building in
2001, we are based on the respective drawings of the architectural and structural project.
(Dhimgjini, Katundi, & Paci, March, 2001)
The structural typology is a masonry structure accompanied by rc columns, typology widely
used in that period. Are evidenced four different masonry thicknesses, 60cm at basement level,
52cm, 34cm, and 17cm. The last thickness is mainly used as a separating wall between rooms.

Figure 49. Case study 1 updated model after interventions (Dhimgjini, Katundi, & Paci, March, 2001)

28 pier = column, spandrel = beam. Both piers and spandrels are equivalent panels constructed of shell elements,
showing the element way of work according the static concept.
136
Stone “masonry structures have large masses due to heavy construction materials. Dead loads
consist of the fixed weight of structural members and the weight of any permanent fixtures
attached to the structure (superimposed loads). Dead loads always remain on the structure and
affect the structure throughout its lifetime”.

Figure 50. The municipality building, worked on ETABs v16.2.0 (June 21, 2019)

6.1.5.1 Materials, mechanical properties after performing laboratory tests on materials

For all case studies treated in this study, laboratory tests were performed, conducted on site by
the company "Altea & GeoStudio 2000" for the generation of data and mechanical
characteristics of materials. In the case of the town hall the focus was on taking and conducting
tests on the brick and mortar material. The procedure performed starting from sampling the
material in the structure, performing the relevant tests and obtaining the test results will be
summarized in this section below. Other aspects of the laboratory tests will be summarized in
the relevant study annexes.

Figure 51. (a) Photo taken while sampling red brick on a perimeter wall panel, inside the basement; (b)
sample of red brick preparing for laboratory test, (c) Sample of red brick during the laboratory test in
printing, (d) Sample of red brick after completion of the test in compression, at the point of destruction
(Altea & geostudio, 2019)

137
Figure 52. (a) Photo taken while sampling white brick on a perimeter wall, the eastern part from behind;
(b) sample of white brick taken on the north façade wall, (c) Sample of white brick during the laboratory
test in printing, (d) Sample of white brick after completion of the test in compression, at the point of
destruction (Altea & geostudio, 2019)

Figure 53. (a) The result of the red brick digimax test for the compression test; (b) + (c) the results of
white brick samples (Altea & geostudio, 2019)

Figure 54. (a) sample of mortar during the compression test, (b) sample of mortar after completion of
the test, point of collapse, (c) test result in digimax (Altea & geostudio, 2019)

Bricks - full red bricks or white silicates are not crushed. From the tests performed the results
obtained are acceptable as they have given good compressive strength. No decompositions have
been found.

Mortar - From the tests performed, mortar has good physical-mechanical properties. Mortar
consists of river sand and cement. In those parts where the walls have been plastered (which are
partial) it is advisable to re-plaster them.

138
Table 10. Table with mechanical parameters of masonry materials after performing laboratory tests,
specifically tests in compression of cubic samples of red brick and silicate-white (Altea & geostudio,
2019)

Materials / Laboratory test

Nr. Parameter Value Unit Type of test Figure


performed
1 Compressive strength – digimax 19.75 Mpa Compression test
results for the red
2 Failure load 294 kN
brick cubic sample-1

1 Compressive strength – direct 18.66 Mpa Compression test


results for the white
2 Failure load 71.7 kN
brick cubic sample-1

1 Compressive strength – direct 15.13 Mpa Compression test


2 Failure load 230 kN results for the white
brick cubic sample-2

1 Elastic modulus E (The Young's 15837 MPa


Modulus)
2 Shear modulus G 1811 MPa
3 Poisson's ratio υ 0.15

Material parameters on ETABS are set to the current state, referring to the laboratory results
performed above (table 10), and reviewing the physico-mechanical parameters according to the
literature.
The masonry behavior is modeled by two different layers accompanied by stress and strain
characteristics (Tomazevic, Damage as a Measure for Earthquake Resistant Design of Masonry
Structures, Slovenian Experience, 2007). The layers represent the vertical stresses S1-1, S2-2
horizontal stresses and shear stresses S12. It is very important to predict the best possible stress-
strain graph for each direction (Baballeku, 2014).

139
Figure 55. A unified model for the seismic analysis of brick masonry structures (Xu, Gentilini, Ju, Wu,
& Zhao, 2018)

The nonlinear analysis Pushover, methodology is able to define capacity curves with
performance point, the shear resistance and collapse mechanisms. It is able to combine different
mechanisms for global seismic performance analyses of buildings with sufficient regularity and
limited height, and take into account the type of connection among the structural elements.

6.1.6 The concept of the foundations

The foundation is continuous, with stone masonry, on two levels. The first level is in the depth
of -2.7m and the second in the level ±0.00. The foundation is realized using two models:
Theoretical model according to Timoshenko and Euler; and the physical model, understanding
the case study.

Figure 56. Theoretical model referring Timoshenko and Euler (left), the case study physical model
(right) (Vesho, Guri, Marku 2019)

Figure 57. Foundation structural plan of the Di Fausto implementing project 1941 (source: Archive)
140
6.1.7 Seismic Parameters

Since the objective of this research is to evaluate the seismic performance of the building and
improve it, we have to show below the elastic response spectrum[29] parameters (CEN Eurocode
8, Eurocode 8: Design of structures for earthquake resistance -Part 1: General rules, seismic
actions and rules for buildings, 2008).
Eurocode 8 have a detailed “specific way to calculate the seismic spectrum. In this case it
depends on several factors: peak ground acceleration PGA[30], the category of the soil, the
predicted magnitude (in the case of our country is M > 5.5) and the behavioral factor. This last
one as a concept is comparable to the inverse of ductility. Given the studies, Albania has a
variety of seismic peak ground acceleration from 0.15-0.3g. (CEN Eurocode 8, Eurocode 8:
Design of structures for earthquake resistance -Part 1: General rules, seismic actions and rules
for buildings, 2008) With the same reasoning as above, we choose the seismic acceleration that
has greater surface in the seismic map. Eventually the selected parameters are:”
- Soil category: B
- Spectral acceleration: ag/g = 0.3m/s2
- Direction: Horizontal
- Behavioral factor: 2.6 (the spectrum is elastic)
- Damping factor: 5%

Figure 58. Elastic demand spectrum, referring Tirana ground parameters (ETABS, 2019)

Given the above explanation in methodology, historical heritage was primarily analyzed to
define seismic parameters and their walls load carrying capacity. “Modal analysis was conducted
in order to determine fundamental mode shapes and natural frequencies of the structure during
free vibration. The purpose of modal analysis is to obtain the maximum response of the structure
in each of its important modes, which are then summed up in an appropriate manner. Modal
analysis of the structure included different modes of vibrations in combination”.

29
A response spectrum is a plot of the peak or steady-state response (ground acceleration) of a series of oscillators
or earthquakes of varying natural frequency, that are forced into motion by the same base vibration.
30
is equal to the maximum ground acceleration that occurred during earthquake shaking at a location. PGA is equal
to the amplitude of the largest absolute acceleration recorded on an accelerogram at a site during a particular
earthquake
141
6.1.8 Seismic analysis results and modal parameters

Figure 59. The first 3 modes of vibrations according the modal analysis (CEN Eurocode 8, Eurocode 8:
Design of structures for earthquake resistance -Part 1: General rules, seismic actions and rules for
buildings, 2008) (ETABS, 2019)

Table 11. Modal participating mass ratios and periods (ETABS, 2019)
Period
Case Mode UX UY SumUX SumUY RX RY SumRX SumRY
sec
Modal 1 0.347 0.0046 0.7411 0.0046 0.7411 0.3605 0.0025 0.3605 0.0025
Modal 2 0.185 0.3388 0.0181 0.3434 0.7591 0.0172 0.1851 0.3777 0.1876
Modal 3 0.108 0.4508 0.0005 0.7942 0.7596 0.0052 0.1528 0.3829 0.3405
Modal 4 0.085 1.1274 0.0003 0.7942 0.7598 0.0001 0.0041 0.383 0.3446
Modal 5 0.07 0.002 0.0003 0.7962 0.7602 0.0006 0.0114 0.3836 0.356
Modal 6 0.063 0.0011 0.0127 0.7974 0.7728 0.0316 0.0017 0.4152 0.3577
Modal 7 0.051 0.006 0.0015 0.8033 0.7744 0.0071 0.0223 0.4223 0.38
Modal 8 0.049 0.0001 0.0815 0.8035 0.8559 0.2134 0.0002 0.6356 0.3802
Modal 9 0.044 0.0298 0.0002 0.8332 0.8561 0.0001 0.0914 0.6357 0.4715
Modal 10 0.037 0.0011 0.0048 0.8343 0.8608 0.0116 0.0042 0.6473 0.4757
Modal 11 0.037 0.0001 0.0009 0.8344 0.8617 0.0027 0.0023 0.6499 0.478
Modal 12 0.036 0.0181 0.0006 0.8525 0.8623 0.0048 0.0847 0.6547 0.5627

Allowed period calculation: [T]= 0.075 * Hb^0.75 (CEN Eurocode 8, Eurocode 8: Design of structures
for earthquake resistance -Part 1: General rules, seismic actions and rules for buildings, 2008)
First mode: T1=0.347s > [T] Translation move on Y-direction
First mode: T2=0.185s Translation move on X-dir. and the presence of torsion
Third mode: T3=0.179s Pure torsion
We can mention in advance that the most problematic part founded above in modal parameters
is a considerable torsion of the structure in global plane in the second mode of vibration. This
phenomenon is problematic for masonry structures in general and also in our case can bring
additional problems in the joining part between two buildings.
142
6.1.9. Local stresses and strain distribution in main facades

Figure 60. Resultant Shell forces on main facade, f1-1 and f2-2 (ETABS, 2019)

Figure 61. Resultant shell stresses S1-1 and S2-2 on the main facade (ETABS, 2019)

143
Figure 62. Shear force distributed on 2 directions, V1-3 and V2-3 (ETABS, 2019)

Figure 63. Resultant shell stresses in the area when the new frame system is linked with existing wall
(ETABS, 2019)

The “minimum principal stresses amount to about 7.13 MPa and they occur in the transition
zone between the ground floor and the upper floor (figure 63). Maximum principal stresses
amount to about 9.67 MPa and they occur above the top of the ground floor and at the first floor
wall panels”. Maximal displacement according combination 1 is 38.3mm on X-direction and
59.8mm on Y-direction. Is noticed that the structure has problems with the displacement and
the creation of plastic hinges on the joints in the areas where the beams merge with walls, exactly
in the meeting point between the new structure and the old part. There are also problems in the
area when basement wall with 60cm width merge with foundation.

144
Figure 64. Seismic Displacements according to Combination 1, Δx-x and Δy-y (ETABS, v.2019)

Figure 65. Maximum story displacements according to seismic actions in two directions E-x, E-y
(ETABS, v.2019)

Figure 66. Comparison between Modal and combination 1 of Maximum story displacements (ETABS,
v.2019)

145
Regarding displacement of the structure, an investigation has been done at the storeys level, to
specifically analyze the reaction of the old structure in relation to the new structure. At this stage
the analysis was done by simulating the model in Etabs according to the combination-1,
considered as the most unfavorable. This combination includes seismic action in the orthogonal
direction in relation to the building, specifically direction X, then combined with "dead loads"
with a coefficient of 1.0*D.L and "live loads" with a coefficient of 0.3*L.L, also, showed in the
modeling parameters above. From investigating and reviewing displacement values we have
these values. The maximum size of displacements according to the combination-1 in the most
fragile direction of the building, captures the maximum value of 6.48mm, while the values of
maximum displacements according to the modal analysis in the most fragile direction of the
building geometry reach the value 0.36mm. Normally there are large differences in
displacements obtained from the most fragile combination compared to the static linear analysis
results.

Figure 67. Story drifts comparison between seismic E-x and E-y direction (ETABS, v2019)

Figure 68. Story drifts comparison between modal analysis and combination-1 (ETABS, v2019)

146
Figure 69. Story shear force distribution against seismic actions Ex-x and Ey-y (ETABS, v2019)

Figure 70. Story shear force distribution against seismic actions Ex-x and Ey-y (ETABS, v2019)

Making an interpretation of the diagrams above is analyzed the static reaction of the structure
for this case, more specifically the diagram of the distribution of shear forces in the local analysis
and the diagram of local moments, the second one taking into account the reaction of addition
which has moment frames structure . The diagrams are taken under the influence of seismic
actions and more specifically the action against the two directions x and y. From the shear-force
diagrams we see that the greatest impact has the direction x where the values of shear stresses
are about 80% higher compared to the direction y, this related to the configuration of the
building in the plan. While there is a significant overrun and change of the diagram in the level-
0 plan. This explains and reflects the change of volumes of the two buildings in that plan-level,
analyzing that the addition starts from ground level 0 and continues to the terrace, while the
existing building is embedded in the ground up to level -2.85, i.e. the basement floor, without
considering the depths of the foundations of the two blocks. Referring to the moment diagrams,
the parameters consist within the allowed values and can be considered insignificant, due to the
volume of the existing building which is massive structural masonry with considerable width.

147
Figure 71. Virtual relative energy/work related to the main façade, related to comb-1 (ETABS, v.2019)

Figure 72. Distribution of the resultiant seismic force F1-1 in 2 front facades, related to comb-1 (ETABS,
v.2019)

Figure 73. Distribution of the resultiant seismic force F2-2 in the two front facades, related to comb-1
(ETABS, v.2019)

148
Figure 74. Distribution of the stress σ-x in the two front facades, related to comb-1 (ETABS, v.2019)

Figure 75. Distribution of the stress σ-y in the two front facades, related to comb-1 (ETABS, v.2019)

Figure 76. Distribution of the Strain ε1-2 in the two front facades, related to comb-1 (ETABS, v.2019)

149
6.1.10. The second phase of BIM modeling through “3muri software”, static nonlinear
analysis and investigations into possible collapse scenarios

Following the seismic analysis (performed in etabs software), for the above case study, it was
judged to perform further seismic verifications in the framework of non-linear analysis through
3Muri software, which specializes in analyzing these types of structures . In this theoretical
framework it is attempted to obtain further information about the object, and also to increase the
degree of structural investigation. Global "nonlinear pushover" analyzes were performed, and
then attempts were made to investigate some of the possible local mechanisms of collapse. So,
for the evaluation of local effects of the panels, the use of calculation models relating to the
isolated fragile parts of the structure is allowed at this analysis stage.

There has always been a tendency to reduce and equivalent the masonry structural system to a
homogeneous and isotropic material, to exploit the technical knowledge of theory of structures
or building sciences. This schematization allows to evaluate the stress and deformation state and
corelate similarly to what happens for reinforced concrete frames or steel structures.

Figure 77. Axonometric model of the building, created in 3Muri v.13 software. Geometric modeling,
creation of volumetrics and data entry of materials

As one of the basic interconnections of BIM modeling, a finite element treatment "F.E.M.
method" would be valuable, also desirable, with which to schematize each individual brick unit
and the reciprocal constraints, however this operation would involve an enormous
computational burden, also, an extremely random relationships. By adopting 3-dimensional
finite elements models, it is possible to obtain an exhaustive modeling for any type of existing
construction and, in particular, for those made entirely of unreinforced masonry, with simple
rigid ribbed slab, which can thus be analyzed in their entirety in this chapter.

The 3-muri calculation model is the numerical parameterization of the global behavior of the
structure, respecting the constitutive bond and cooperation of the material parameters or data.
The most frequent cause of errors in structural design is the difficulty to identify calculation
models that are effectively representative of structure real behavior.

150
Figure 78. Computational model generated in 3Muri showing three of the component elements, piers
spandrels and rigid nodes. The model presented in the axonometric version and the calculation model of
the main facade in the western position of the building

Following the introductory explanation above, the 3Muri model and concept, always starting
from the basic concept of equivalent frame model, rigorously addresses the bending mechanism
considering the effective redistribution of the compressions to the partialization and
discretization of the section, also to the achievement of the maximum compressive strength of
the panel, while describing the “shear mechanism” according to the bond effect.

Structural masses and stiffnesses are distributed over all 3 dimensional model of degrees of
freedom. The connection nodes and joints, belonging to a single wall panel, maintain their
"degrees of freedom" in the local reference plane, while the nodes belonging to several walls
connected in axonometric projection, must necessarily have the “degrees of freedom” in the
global reference of the structure, considered “three-dimensional nodes”.

151
Figure 79. Image of the summary table of the number of analyzes performed in the framework of
pushover analysis in 3Muri-v.13

Figure 80. Summary diagram of structure capacity curves according to 24 nonlinear analyzes according
to the combination of 2 seismic directions

152
600000
X - direction

500000

C.01 +X /Uniform L.
C.02 +X /Static L.
400000
Base Shear Force [daN]

C.03 -X /Uniform L.
C.04 -X /Static L.
C.09 +X /Uniform L.
300000 C.10 +X /Uniform L.
C.11 +X /Static L.
C.12 +X /Static L.
200000
C.13 -X /Uniform L.
C.14 -X /Uniform L.
C.15 -X /Static L.
100000
C.16 -X /Static L.

0
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
Roof displacement [cm]
Figure 81. +X and -X direction combined capacity diagrams, processed from 3Muri numerical data

600000
Y - direction

500000
C.05 +Y /Uniform L.

C.06 +Y /Static L.

400000
Base Shear Force [daN]

C.07 -Y /Uniform L.

C.08 -Y /Static L.

C.17 +Y /Uniform L.
300000 C.18 +Y /Uniform L.

C.19 +Y /Static L.

C.20 +Y /Static L.
200000
C.21 -Y /Uniform L.

C.22 -Y /Uniform L.

C.23 -Y /Static L.
100000
C.24 -Y /Static L.

0
0 1 2 3 4 5 6
Roof displacement [cm]
Figure 82. +Y and -Y direction combined capacity diagrams, processed from 3Muri numerical data

153
Table 12. Summary table of results obtained, after performing nonlinear analyzes on 3Muri v.13
software
No Seism Seismic α NC α SD α DL dm/d Capacity Curve
dir. load t NC
1 +X Uniform 1.438 1.404 1.325 1.536 Capacity curve 01 / Analysis no.01 / +X dir./Eccenticity 0cm

dt=2.20cm [NC] dm=3.38cm [NC] T*=0.465s

Analysis-01/Mechanism P.1 /Main façade masonry Analysis-01/Mechanism P.17 /Internal hall masonry
/seismic dir.+X/seismic load =uniform /seismic dir.+X/seismic load =uniform

Analysis-01/Mechanism P.15 /2nd Internal hall Analysis-01/Mechanism P.08 /Back façade masonry
masonry /seismic dir.+X/seismic load =uniform /seismic dir.+X/seismic load =uniform

Analysis-01/Mechanism P.11 /South side façade Analysis-01/Mechanism P.05 /North side façade
masonry /seismic dir.+X/seismic load =uniform masonry /seismic dir.+X/seismic load =uniform

154
No Seism Seismic α NC α SD α DL dm/d Capacity Curve
dir. load t NC
2 +X Static 1.193 1.135 1.055 1.203 Capacity curve 02 / Analysis no.02 / +X dir./Eccenticity 0cm
forces

dt=3.00cm [NC] dm=3.61cm [NC] T*=0.549s

Analysis-02/Mechanism P.1 /Main façade masonry Analysis-02/Mechanism P.17 /Internal hall masonry
/seismic dir.+X/seismic load =static /seismic dir.+X/seismic load =static

Analysis-02/Mechanism P.15 /2nd Internal hall Analysis-02/Mechanism P.08 /Back façade masonry
masonry /seismic dir.+X/seismic load =static /seismic dir.+X/seismic load =static

155
Analysis-02/Mechanism P.11 /South side façade Analysis-02/Mechanism P.34 /Internal masonry
masonry /seismic dir.+X/seismic load =static /seismic dir.+X/seismic load =static

No Seism Seismic α NC α SD α DL dm/d Capacity Curve


dir. load t NC
4 -X Static 0.949 0.890 1.582 0.951 Capacity curve 04 / Analysis no.04 / -X dir./Eccenticity 0cm
forces

dt=2.88cm [NC] dm=2.74cm [NC]


T*=0.548s
Not satisfied verification
Analysis-04/Mechanism P.1 /Main façade masonry Analysis-04/Mechanism P.17 /Internal hall masonry
/seismic dir.-X/seismic load =static /seismic dir.-X/seismic load =static

156
Analysis-04/Mechanism P.15 /2nd Internal hall Analysis-04/Mechanism P.08 /Back façade masonry
masonry /seismic dir.-X/seismic load =static /seismic dir.-X/seismic load =static

Analysis-04/Mechanism P.05 /North side façade Analysis-04/Mechanism P.11 /South side façade
masonry /seismic dir.-X/seismic load =static masonry /seismic dir.-X/seismic load =static

Analysis-04/Mechanism P.10 /S.Perimetral masonry Analysis-04/Mechanism P.06 /N.Perimetral masonry


/seismic dir.-X/seismic load =static /seismic dir.-X/seismic load =static

157
No Seism Seismic α NC α SD α DL dm/d Capacity Curve
dir. load t NC
8 -Y Static 1.317 1.256 1.093 1.460 Capacity curve 08 / Analysis no.08 / -Y dir./Eccenticity 0cm
forces

dt=2.76cm [NC] dm=4.03cm [NC] T*=0.525s


Analysis-08/Mechanism P.1 /Main façade masonry Analysis-08/Mechanism P.17 /Internal hall masonry
/seismic dir.-Y/seismic load =static /seismic dir.-Y/seismic load =static

Analysis-08/Mechanism P.11 /South side façade Analysis-08/Mechanism P.05 / North side façade
masonry /seismic dir.-Y/seismic load =static masonry /seismic dir.-Y/seismic load =static

158
Analysis-08/Mechanism P.16 /Internal masonry Analysis-08/Mechanism P.34 /Internal masonry
/seismic dir.-Y/seismic load =static /seismic dir.-Y/seismic load =static

No Seism Seismic α NC α SD α DL dm/d Capacity Curve


dir. load t NC
9 +X Uniform 1.392 1.360 1.331 1.475 Capacity curve 09 / Analysis no.09 / +X dir./Eccenticity
68cm

159
dt=2.23cm [NC] dm=3.29cm [NC] T*=0.469s
Analysis-09/Mechanism P.1 /Main façade masonry Analysis-09/Mechanism P.17 /Internal hall masonry
/seismic dir.+X/seismic load =uniform /seismic dir.+X/seismic load =uniform

Analysis-09/Mechanism P.15 /2nd Internal hall Analysis-09/Mechanism P.08 /Back façade masonry
masonry /seismic dir.+X/seismic load =uniform /seismic dir.+X/seismic load =uniform

No Seism Seismic α NC α SD α DL dm/d Capacity Curve


dir. load t NC
11 +X Static 1.211 1.151 1.048 1.221 Capacity curve 11 / Analysis no.11 / +X dir./Eccenticity
forces 68cm

dt=3.03cm [NC] dm=3.70cm [NC] T*=0.552s


Analysis-11/Mechanism P.1 /Main façade masonry Analysis-11/Mechanism P.17 /Internal hall masonry
/seismic dir.-X/seismic load =static /seismic dir.-X/seismic load =static

160
Analysis-11/Mechanism P.15 /2nd Internal hall Analysis-11/Mechanism P.08 /Back façade masonry
masonry /seismic dir.-X/seismic load =static /seismic dir.-X/seismic load =static

No Seism Seismic α NC α SD α DL dm/d Capacity Curve


dir. load t NC
12 +X Static 1.214 1.156 1.037 1.226 Capacity curve 12 / Analysis no.12 / +X dir./Eccenticity
forces 68cm

dt=3.03cm [NC] dm=3.70cm [NC] T*=0.552s


Analysis-12/Mechanism P.1 /Main façade masonry Analysis-12/Mechanism P.17 /Internal hall masonry
/seismic dir.+X/seismic load =static /seismic dir.+X/seismic load =static

Analysis-12/Mechanism P.15 /2nd Internal hall Analysis-12/Mechanism P.08 /Back façade masonry
masonry /seismic dir.+X/seismic load =static /seismic dir.+X/seismic load =static

161
No Seism Seismic α NC α SD α DL dm/d Capacity Curve
dir. load t NC
13 -X Uniform 1.643 1.604 1.403 1.805
14 -X Uniform 1.430 1.402 1.456 1.535
15 -X Static 1.159 1.107 1.202 1.171
forces
16 -X Static 1.423 1.351 1.101 1.448
forces
17 +Y Uniform 1.418 1.387 1.309 1.514
No Seism Seismic α NC α SD α DL dm/d Capacity Curve
dir. load t NC
18 +Y Uniform 1.219 1.203 1.371 1.276 Capacity curve 18 / Analysis no.18 / +Y dir./Eccenticity -235

dt=2.14cm [NC] dm=2.73cm [NC] T*=0.460s


Analysis-18/Mechanism P.1 /Main façade masonry Analysis-18/Mechanism P.08 /Back façade masonry
/seismic dir.+Y/seismic load =uniform /seismic dir.+Y/seismic load =uniform

Analysis-18/Mechanism P.11 /South façade Analysis-18/Mechanism P.05 /North façade masonry


masonry /seismic dir.+Y/seismic load =uniform /seismic dir.+Y/seismic load =uniform

162
No Seism Seismic α NC α SD α DL dm/d Capacity Curve
dir. load t NC
19 +Y Static 1.250 1.193 1.021 1.268
forces
No Seism Seismic α NC α SD α DL dm/d Capacity Curve
dir. load t NC
20 +Y Static 1.087 1.041 1.088 1.094 Capacity curve 20 / Analysis no.20 / +Y dir./Eccenticity -235
forces

dt=2.87cm [NC] dm=3.14cm [NC] T*=0.535s


Analysis-20/Mechanism P.1 /Main façade masonry Analysis-20/Mechanism P.08 /Back façade masonry
/seismic dir.+Y/seismic load =static /seismic dir.+Y/seismic load =static

163
Analysis-20/Mechanism P.11 /South façade Analysis-20/Mechanism P.34 /Internal masonry
masonry /seismic dir.+Y/seismic load =static /seismic dir.+Y/seismic load =static

No Seism Seismic α NC α SD α DL dm/d Capacity Curve


dir. load t NC
21 -Y Uniform 1.253 1.239 1.361 1.316
22 -Y Uniform 1.314 1.302 1.490 1.408
No Seism Seismic α NC α SD α DL dm/d Capacity Curve
dir. load t NC
23 -Y Static 1.102 1.060 1.061 1.113 Capacity curve 23 / Analysis no.23 / -Y dir./Eccenticity +235
forces

dt=2.75cm [NC] dm=3.06cm [NC] T*=0.520s


Analysis-23/Mechanism P.1 /Main façade masonry Analysis-23/Mechanism P.08 /Back façade masonry
/seismic dir.-Y/seismic load =static /seismic dir.-Y/seismic load =static

164
Analysis-23/Mechanism P.11 /South façade Analysis-23/Mechanism P.05 /North façade masonry
masonry /seismic dir.-Y/seismic load =static /seismic dir.-Y/seismic load =static

No Seism Seismic α NC α SD α DL dm/d Capacity Curve


dir. load t NC
24 -Y Static 1.065 1.047 1.106 1.081 Capacity curve 24 / Analysis no.24 / -Y dir./Eccenticity -235
forces

dt=2.73cm [NC] dm=2.95cm [NC] T*=0.520s


Analysis-24/Mechanism P.1 /Main façade masonry Analysis-24/Mechanism P.08 /Back façade masonry
/seismic dir.-Y/seismic load =static /seismic dir.-Y/seismic load =static

165
Analysis-24/Mechanism P.11 /South façade Analysis-24/Mechanism P.05 /North façade masonry
masonry /seismic dir.-Y/seismic load =static /seismic dir.-Y/seismic load =static

Analysis-24/Mechanism P.22 /Internal masonry Analysis-24/Mechanism P.32 /Internal masonry


/seismic dir.-Y/seismic load =static /seismic dir.-Y/seismic load =static

166
6.1.10.1 Analysis of an effective consolidation strategy, making assessments, without
compromising architectural values and with relevant simulations

From the analyzes performed in 3Muri software, although the building reacts well enough from
a global perspective and shows a satisfactory structural performance, from careful
investigations, some areas considered weak and fragile were identified. Thus, according to the
list generated by the program in table.12 on the verifications performed in the framework of
nonlinear analysis, it must be accepted that the structure shows a satisfactory performance in
3Muri software. It successfully passes 22 complete analyzes showing an vulnerability index α
>1 according to the software evaluation method related to the evaluation parameters of the
Eurocode standard. Meanwhile in the analysis no.04 of the seismic load "static force", the
direction of the shock -X, the parameters are not satisfied with the performance of the structure,
so it fails, although the values are relatively close to the evaluation index 1. Meanwhile in the
analysis no.24 of seismic load "static forces", direction -Y again the structure reacts poorly and
shows fragility by not satisfying the parameters required to be verified, where the index is very
close to the value 1, we can rely on an in-depth interpretation.

So referring to these 2 analyzes, we are interested in conducting further investigations on the


capacity and performance of the most endangered masonry. Meanwhile, the respective
mechanisms of these panels and their respective parameters are summarized in table.12
discussed in the paragraph above. Re-emphasizing that the thesis does not attempt to provide
solutions or details of reinforcement projects, this will not limit us to simulate panels with some
reinforcement techniques, in the framework of BIM modeling and extracting as many structural
parameters and recommendations, to increase the efficiency of modeling. So at this stage what
will be proven is the testing and simulation of selected panels with some minimal intervention
techniques, which aim to provide effective solutions to address the structural issue of masonry,
increasing their performance, in objects of this category, without directly affecting the
architectural aesthetics of the building.

Referring to the no.04 analysis of pushover simulations, two masonry panels were selected to
be simulated in the software. It is about the panel no.01 of the masonry that corresponds to the
main facade positioned in the western direction of the building, this is one of the panels that
reacts poorly and shows fragility at this stage. Also in the same analysis is selected panel no.03
of the internal masonry of the building near the longitudinal hall, this panel shows some areas
where the wall fails and creates local collapse mechanisms, which risk the performance of the
structure.

In addition to these panels in analysis no.24 as mentioned above, 2 other masonry panels were
selected for analysis. Since the direction of seismic forces in this analysis comes in the direction
-Y, the selected panels are oriented according to the transverse direction, namely panel no.25
which corresponds to the southern side facade of the building, and the second panel is no.16
which corresponds to a partial internal wall partially on the first two floors and a perimeter side
167
wall on the second floor level, also this panel shows fragility and local collapse mechanisms
which should be treated with care especially in the proposals for rehabilitation interventions.

Regarding the situation presented in the above panels after performing the second phase of
simulations, which shows the mechanisms of collapse of 2 of the most fragile facades, the
following has been advanced with an intervention strategy in the framework of seismic retrofit.
The proposals are conceived in such a way that they do not affect the aesthetics of the respective
facades, but at the same time significantly increase the seismic performance of the wall. The
"FRCM type of reinforcement" method is recommended, where this reinforcing layer is added
to the masonry panel in its inner part. Specifically the selected material is "GeoSteel G1200,
Kerakoll" with the following data and features:

Figure 83. Physico-mechanical parameters and characteristics of the recommended reinforcement layer
"Geosteel g1200", according to the database used in 3Muri software

Table 13. Technical data according to Kerakoll quality standard (Kerakoll, 2021)
Frabric-data
Trefolo 3x2 ottenuto unendo fra loro 5 filamenti, di cui 3 rettilinei e 2 in avvolgimento con elevato angolo
di torsione
area effettiva di un trefolo 3x2 (5 fili) Atrefolo 0,538 mm2
n° trefoli/cm 3,14 trefoli/cm
massa (comprensivo di termosaldatura) ≈ 1200 g/m2
carico di rottura a trazione di un trefolo > 1500 N
resistenza a trazione del nastro, valore caratteristico σnastro > 3000 MPa
resistenza a trazione per unità di larghezza > 4,72 kN/cm
modulo di elasticità normale del nastro Enastro > 190 GPa
deformazione a rottura del nastro, valore caratteristico εnastro > 1,5%
spessore equivalente tf ≈ 0,169 mm

168
Figure 84. Image of the component assembly of the material FRCM GeoSteel G1200, (Kerakoll, 2021)

The placement of the reinforcing layer presented above will be applied on the inside of the
facade masonry, will be fixed with the existing masonry and will perform in normal
environmental conditions. Reinforcement applications in transverse masonry are placed on both
sides of the building to maintain the sense of symmetrical distribution of masses and rigidities.
The application of FRCM from karakol products was applied for 2 longitudinal panels
ascertained by analysis no.04 according to the direction + X. After simulations this type of
application is not enough to avoid failures in the 2 transverse panels according to the -Y
direction. In these panels, in addition to FRCM applications, steel-bracing systems have also
been applied, which enable a significant increase in performance. Their configuration is applied
in simple logic according to the openings located in the masonry (doors, windows,), and
necessarily their application in the interior of the masonry panels of the facades.

Table 14. Configurations used for reinforcements, presented in the plan and facade
* Positioning of the panels where the intervention was applied,
** Data on their geometric configuration

Bracing system application and configuration in Bracing system application and configuration in panel
panel no.16 of the internal masonry no.11 of the façade masonry

169
Numerical data and technical parameters of Numerical data and technical parameters of
profiles profiles

As for the results obtained after performing the software simulations, they are summarized in a
tabular way below, giving the possibility of relevant comparisons between models, local
mechanisms and key numerical parameters.

170
Table 15. Summary table of results obtained after reinforced building simulations
Case [1], Summary diagrams of the analysis no.04 +Xdir./static. The capacity before and after the intervention in
the masonry of longitudinal (south-north) facades, processed with 3Muri data

500000

450000

Base Shear Force [daN] 400000

350000

300000

250000 C.04 -Xdir.


Static
200000 C.04 -Xdir -
Reinforced
150000

100000

50000

0
0 1 2 3 4 5
Roof displacement [cm]
Comparisons
Before application After reinforcement application
Analysis no.04 +X /Static load/panel no.01 Analysis no.04 +X/Static load/panel no.01
No Seism. Seism. α NC α SD α DL dm/d No Seism. Seism. α NC α SD α DL dm/dt
. dir. load t NC . dir. load NC
04 +X Static 0.949 0.890 1.582 0.951 04 +X Static 1.471 1.403 1.221 1.511
forces forces
dt=2.88cm [NC] dm=2.74cm [NC] T*=0.548s dt=2.84cm [NC] dm=4.29cm [NC] T*=0.506s
Panel of local mechanism model / panel.01 Panel verified mechanism model / panel.01

Panel of local mechanism model / panel.17 Panel verified mechanism model / panel.17

Case [2], Summary diagrams of the analysis no.24 -Ydir./static. The capacity before and after the intervention in
the transverse masonry, processed with 3Muri data

171
500000

450000

400000

Base Shear Force [daN]


350000

300000
C.24 +Ydir. Static
250000 /Reinforced

200000 C.24 +Ydir. Static

150000

100000

50000

0
0 1 2 3 4 5 6
Roof displacement [cm]
Comparisons
Before application / seismic parameters After reinforcement application / seismic parameters
Analysis no.24 -Y/Static load Analysis no.24 -Y/Static load
No Seism. Seism. α NC α SD α DL dm/d No Seism. Seism. α NC α SD α DL dm/dt
dir. load t NC dir. load NC
24 -Y Static 1.075 1.037 1.160 1.081 24 -Y Static 1.741 1.671 1.671 1.842
forces forces
dt=2.73cm [NC] dm=2.95cm[NC] T*=0.520s dt=2.59cm [NC] dm=4.77cm[NC] T*=0.466s
Panel verified mechanism model / panel no.11 Panel verified mechanism model / panel no.11

Panel verified mechanism model / panel no.16 Panel verified mechanism model / panel no.16

172
6.1.10 Summarized conclusions for case one

In this paragraph there will be a discussion on the results obtained for this case study, i.e. a
section with preliminary conclusions. As mentioned earlier, this study focuses on historical
heritage masonry structures situated in Tirana, “located in a seismically active zone. One of the
objectives was to analyze damage mechanisms and seismic vulnerability of the selected
building. First a brief description of structural features and architectural characteristics of Italian
typology was presented. This is followed by modelling one of the most typical building of this
period to visualize structural response behind seismic events. A 3D model was prepared in order
to show behaviour of the structure and its probable local and global weaknesses under seismic
actions. The modal analysis is applied to predict possible damages and seismic vulnerability in
weak zones of the structure under expected seismic intensity”.
The static and modal analysis results have revealed that the critical section for the selected
building is the transition zone between the ground floor and first floor, also the area where the
old building is connected with the extension new structure. The most critical stresses calculated
during the static analysis occurred at the connection joints between old structure with another
typology and the new frame building, also where the basement is linked with the upper structure
and slabs. “Results show that the node interaction between the supports and the walls plays an
important role in the dynamic behaviour of the structure. It may be considered as risky in terms
of creating structural stability problems. The results also show that structural problems and
damage to these houses generally occur in the critical stress parts, and these results prove
accuracy of the numerical approach, by verifying the problems” that were identified on site.
The addition of the new structure has positively influenced on reducing the period of vibrations
and the bending momentum in global aspect, but on the other hand increases the shear force on
the base. Increases stresses on the facades of the building which were problematic even earlier
and also promotes an increase in carvings and cracks on the façade. Most visual and more
173
pronounced is the damage of the old building in the area where it joins the new object. This is
evident from the seismic performance analyzed above in the ETABS. These findings show a
significant reduction in the seismic performance of the building, judging the structure of two
different types of construction.
Regarding this case study, an in-depth investigation has been done, regarding the architectural
aspects and those of the restoration of the cultural heritage. This case study is part of the objects
of cultural heritage of Tirana, listed in category B. It is protected by law and in this category of
objects cannot be made excessive interventions, especially in the facade, where some of the
decorative elements are fanatically preserved, and in in the same way the Italian architectural
style. In these typologies, interventions or reinforcements can be made only when the potential
structural hazard is presented and in cases when its static stability can be questioned.

Regarding my analysis and the methodology followed, referring to the field findings and dealing
with the archival project, or other scientific studies related to this building, during the years in
this object many structural and non-structural interventions have been made. So, the building
has gone through a varied large transition. We can mention interventions that have affected the
building, its shape and its architecture, such as:

• Partial and complete reconstructions including finishes;


• Floor additions on the terrace of the existing building, not following the existing
architectural plan;
• Side additions in the eastern part, which can be considered the most extreme and recent
structural intervention made to the building, also its architecture;
• Changes in the size of the windows in the two front facades;
• Change in the number of windows in the facade;
• Replacement of decorative elements of the period 1941;
• Plastering and painting of the facade in 4 different periods;
• Application of seismic joint between the two blocks, the existing one and the 2001
addition;
• Re-positioning of internal partition walls,
• Moving walls and re-configuring internal floor plans, at least 3 times;
• Door openings in interior walls;
• Demolition of structural walls, in the part which is in contact with the addition of 2001;
• Frequent interventions in the floor layers on the existing slabs;
• Installation of consolidating elements, which can be seen on the facade;
• Significant structural interventions in the basement floor of the building;
• Partial consolidation interventions and retrofitting in the foundations of the building;
• Total energy retrofit of the building;
• Re-conception of the infrastructure around the building.

One of the most sensational interventions and that has left visible marks on the body of the
building is the addition of 2001. In this period, Tirana was in a phase of development and
transition, after coming out of the long dictatorial period. There was a lot of dynamics in the
development of the city, and there was no attention to buildings with architectural-historical
values. The building had the status of a cultural monument, but in the period in question there
was no conservative legislation on such interventions. Thus, regarding the need of the building
for expansion, it was decided to make a significant structural addition to the back of the existing
174
building, specifically in the position of the eastern facade. The geometry and plan evidencing of
this structural addition was shown above in figure.48 where the contour of the additional
architectural plan is distinguished in green line.

The structure of the addition consists of "moment-frame" elements, i.e. beam-column system
positioned and oriented in one direction, while they are connected with secondary beams in the
other direction. The expansion of the building continues uniformly in the 2 front facades,
respectively for the ground floor and the first floor, with a volume reduction on the second floor.
In the back is realized a considerable space to create a meeting / conference room for the needs
of the municipality, regarding the positioning in the plan of geometry we are dealing with a
semi-cylindrical shape in the middle, limited by two more advanced blocks of the extension of
the two front facades. The structure of the addition, it is worth noting that there is another static
behavior and dynamic reaction, compared to the masonry structure of the existing building.
These aspects are explained above in the seismic response analysis of the building complex. The
solution of the structural engineer made that a seismic joint with a thickness of 12cm was placed
between the two objects, and this solution was effective in order not to influence the different
reactions of the two types of structural systems. However, even this part was clarified above in
the conclusions of the modal analysis. The foundations of the additive structure are monolithic
footings connected with connecting beams in two directions to have uniformity of reactions,
foundation sagging and foundation reductions. The seismic joint continues from the terrace to
the foundation between the two buildings.

From the architectural point of view and within the theories of restoration, we have two different
structural typologies fused into one, but at the same time we have 2 blocks which have a
completely different history from each other. There are big time differences between them. The
old building of 1941 carries in itself many values and history. There is the hand of the architect
F. Di Fausto, his project-idea and the Italian architectural style of the period of the beginning of
the XIX century.

The building today has reached its 80th anniversary and its aesthetics is an identifying and
reference object for the city. Now with a slightly newer volume of the addition, they coexist in
a building with the same name "Tirana municipality". If we make a connection with the theories
of restoration and the Venice Charter for Restoration, in this object there are some aspects that
are in conflict. The addition made in 2001, is not considered addition in the full sense, there is
no visible separation of objects, the addition is not well documented with all phases of
intervention, the addition is not visible and does not show the time difference between objects.
Perhaps for many restorers, historians or architecture critics, this addition tends to go against
restoration theories and make a historical fake, disguised as an extension of F. Di Fausto's
authentic building. For any citizen who can see the building for the first time cannot distinguish
the difference between the periods of objects. Perhaps this is not a problem for many
professionals in the field, and can be considered an effective intervention and in line with the
development of the building for the requirements of the institution. This will normally remain
an open topic as long as there is no genuine debate in Tirana on the values and architectural
richness of the many buildings that are part of the cultural heritage.

In conclusion of this part, to connect once again with the structural aspect, the building performs
well, has reacted well to the moderate earthquakes of 2019 and results in a satisfactory structural
and seismic performance. But this does not mean that the building may be able to withstand a
175
new 50-year transition, with city dynamics, atmospheric disturbances and future seismic events.
A new research question arises, "How to renew the structural performance of these complex
structural typologies, which carry architectural values in themselves?". If the question is better
re-formulated, the main problem appears in the fact, how to intervene in the object without
damaging its aesthetics and architecture, how to integrate with additions made in different
periods, and the most importantly “how to find a mathematical non-linear connection to link
pre-conceived engineering F.E.M. simulations or collapse scenarios with restoration theories /
principles?”. This has been one of the dilemmas initially, and the impetus later to launch and
conduct this study.

There are many studies and literatures dealing with the methodology and techniques of structural
consolidation of old masonry buildings, traditional classical methods, modern and advanced
methods which are briefly mentioned in the chapter "the state of art". However, this study does
not provide technical details or engineering solutions for the application of structural
interventions in such buildings.

In this study, an attempt is made to establish a real connection between consolidation,


retrofitting and interventions according to some basic principles of restoration. So the creation
of a matrix, where any typology of intervention or structural retrofitting, to be automatically
linked parametrically with the relevant theory of restoration, mainly basic principles of
restoration charters. Not being afraid of contrast between the new building/addition/partition
against the old existing building; the time difference between the old and the new one should be
clearly shown; to intervene for structural consolidation without affecting the aesthetics /
architecture, until the static stability of the building is endangered; if the addition increases the
static performance of the structure and solves the problem of the new function can be applied;
etc. This theoretical matrix can be applicable in many current software’s that use the BIM
methodology (building information modelling), where through some algorithms, some
interventions will automatically blocked to be applied if the required principle is not respected.
This theory simply means dissatisfaction with the above elements. To have the option of
parametric recommendations in interventions, just as parametric design is applied in the
generation of forms, this can also be applied to the techniques of interventions and their
form/shape in existing objects. It is also recommended to install a monitoring system with
sensors, and a robotic system to control the performance of each building without limit, would
help the progress and maintenance of heritage values in time.

176
6.1.10.1 Discussions on the results obtained from the simulations in 3Muri

Usually the knowledge level represents a critical phase for the definition of reliable structural
3d models of cultural heritage buildings.

Exactly for this aspect, different numerical “models should be used. The proposed analyzes show
a possible approach to investigating the seismic capacity and performance of an old heritage
masonry building, considering two different levels of accuracy: the first is a global model based
on a simplified seismic approach, and the second is based on the application of a classical
pushover analysis, with nonlinear characteristics with a 3D macro-element model.”

Thus after performing the modal analysis, the nonlinear static analysis was performed through
the 3MURI software to obtain the capacity curves and to have clarity on their collapse
mechanisms. The case study dealt with here emphasizes that, even in a fairly simple
construction, with regular geometry and symmetric distribution of stiffness, many special
aspects can be found after a detailed and careful investigation, divided into two phases, those
field and experimental modeling.

The basis of these pushover analyzes in 3Muri, was the performance of seismic safety controls
of the building verified in the ultimate limit state ULS, according to the Eurocode standard. As
interpreted in depth in paragraph 6.1.10.1, after performing the simulations, it was noticed that
the seismic controls among 24, only 2 of them were not satisfied referring to the vulnerability
indexes α (combined according to 3 levels), obtained from software. In step no.04 -Xdir.
vulnerability index values <0 were found, but close to the limit values. In this analysis dt (the
target displacement of the MDOF system) dm (the ultimate displacement of the MDOF system),
in numerical values dt = 2.10cm compared to dm = 3.88cm, with a ratio dm / dt = 1.85.
Vulnerability index α (NC) = 0.949, while α (SD) = 0.890. No analysis no.24 -Ydir. low values
of the vulnerability index and dt <dm were found, specifically dt = 2.73cm compared to dm =
2.95cm, with a ratio dm / dt = 1.08. But, even if we carefully investigate the other steps, local
elements of masonry can be found which are fragile to be considered. From the investigations
of each step, a considerable number of local collapse mechanisms have been identified, which
are summarized in table.12 accompanied by numerical data, combined with the corresponding
graphical mechanisms generated by 3Muri.

In relation to these data summarized above, some specific interventions for seismic
improvement of the structure were foreseen. First, the reinforcement of the masonry was
considered, through an intervention with FRCM Geosteel g1200 by increasing the mechanical
properties of the existing masonry, to eliminate the mechanisms found in “step 04 -Xdir”. and
to increase the seismic safety factor of buildings.

This simple intervention in terms, proved effective from the first attempt, and this is shown in
paragraph 6.1.10.1 by the results summarized there. The application was made in the inner part
of the masonry, specifically in 3 longitudinal panels, oriented in the X-direction of the building
in plan. We emphasize that the intervention does not affect the aesthetics of the facade of the
building, part of the cultural heritage.

Later, the intervention in the transverse panels of the masonry Y-dir. was simulated, after
interpreting the results from “analysis no.24 -Ydir”. The focus was on intervening to improve
177
the mechanical properties of the masonry, through the reinforcing layer with FRCM Geosteel
g1200. The intervention in this case was not enough to eliminate all the mechanisms of collapse
and was followed by a second intervention, the establishment of several steel-bracing systems,
the relevant data of which are summarized in table 15 of paragraph 6.1.10.1. This double
intervention provided a significant increase in masonry performance in terms of strength and
rigidity.

If we make comparisons with modal analysis we have changes in values also in terms of
vibration periods. In nonlinear pushover analyzes we have higher values of vibration periods.
This difference is also affected by not considering the addition of the building in 3Muri software.
However, there are aspects that show a higher care for performance, found after the analysis in
3Muri. Useful information which will enrich the BIM model targeted in the initial objectives
with numerous structural data.

178
6.2 CASE II - General overview of the “Casa del Fascio”, Polytechnic University of Tirana
Architectural identification, survey process and structural evaluation

The building of the Casa del Fascio was designed by Gherardo Bosio between 1939 and 1940.
The conception of the architectural complex of the Littorio as an urban theater, surrounded by
mighty tiers of travertine on the sides, which assumes the building of the Casa del Fascio as an
artificial scenographic element placed in front of the natural scenography of the hill, lit up in the
citizen the awareness of feeling part integral to urban representation.

Figure 85. Casa del Fascio position and relations with other cultural heritage at the boulevard (Credits:
S. Agalliu)

The multiple altimetric movements of the ground given by the terraces “and the stylobate of the
Casa del Fascio, on the one hand create multiple points of view of the space of the square, on
the other organically hold together the buildings that construct it, as if there were a monumental
podium” excavated waiting for the architectures that will rise above it. The building of the Casa
del Fascio, characterized by compact ashlar parallelepipeds intersected with each other that give
the impression of a fortress, evokes reminiscences of the traditional Albanian tower according
to some, but more likely inspired by the type of the Florentine Renaissance palace, although
revisited in a modern key . This creation becomes the icon of the New Tirana, being re-proposed
the same year in the project for the Albanian pavilion at the Fiera del Levante in Bari and at the
Triennial Exhibition of the Terre d’Oltremare in Naples. For this reason, the almost unchanged
re-proposal of its form in the project of the government square in Gondar by Bosio becomes
curious.

This formal coincidence shakes many of its author's considerations on the character of places
and on the relationship with local cultures. “The uniform treatment of the ashlar overcomes the
traditional vertical stratification of the facade in the basement-elevation-conclusion, giving the
building an almost metaphysical purity. The temple of the new Albania lives a condition of
formal abstractness compared to the other buildings of the Littorio complex, a similarity of
sensations that is felt in the relationship to the EUR-Roma with the Palazzo della Civiltà,
different forms but recurring characters: purity of volumes, symmetry, massiveness, elevated
position, seriality, uniformity of materials”.
179
The building had been built with a reinforced concrete structure buffered by solid brick masonry,
the windows framed by a concrete frame were covered with white Carrara marble, the same
podium covered in travertine was built with a reinforced concrete structure at the inside which
there were some underground rooms.

Today the building houses the Rectorate of the Polytechnic of Tirana, the extensions on the back
are shortly after the construction of ‘1939.

6.2.1 Architectural Survey and structural on-site investigation

Also in this case the same methodology was followed, the procedure explained in Chapter V,
after the analysis of case study-1. The first phase was the on-site study, where through the
organization of "Cultural Heritage Restoration and Conservation" subject, with students of
architecture and Civil engineering classes, under the guidance of academic staff, the process of
architectural survey was successfully completed, with more care throughout a five week period.

The processes that were followed in this survey phase are "Orthogonal photography with many
cloud points of the facades of the building, processing according to the method of
photogrammetry, drone photography, sketches and drawings of architectural elements,
processing of elements in Photoshop, documentation and digitalization of the archival project
in AutoCAD, investigation of interventions in the building over the years, investigation on
additions and new blocks, investigation on material degradation, moisture in the masonry,
opening and cracking of marble panels on the facade, possible damage to the masonry and the
concrete frame actual state, the presence of moss and stone mold, parasitic vegetation, structural
retrofit interventions, the impact of technological networks and installations on the building, the
infrastructure around the building and the connection with the center, the urban planning of the
area and the dynamics of urban development of the area, the function of the building and
auditorium spaces, etc”. All these processes are treated in a concise way in this study, also a part
of the material are found in the annexes of the thesis.

The feedback received from the students research and works was at satisfactory levels,
meanwhile through this process, and the methodology used in this study, has been attempted
very carefully to encourage the students, a culture on the works of architectural survey and in-
depth study of the “Restoration of Cultural Heritage”. Using a well-structured source of
professionals at this stage, a combination of experiences was made between Civil engineers and
architects, opening a genuine scientific debate within the audience, regarding the values of
Cultural heritage objects, and how they should be treated in it. the future.

The process of orthogonal photography and processing with the method of photogrammetry: As
explained above, in the first phase of the architectural survey, the 4 facades of the building were
worked in great detail through the processing of orthogonal photos, with the technique of
photogrammetry. Below is shown the result of this on-site important work process.

180
Figure 86. Image processed with photogrammetry of the main facade of the building

Figure 87. Image processed with photogrammeter of the facade from behind

Figure 88. Photogrammetrically processed images of the side facades

181
Figure 89. First aeral photo, showing the volumetric blocks, made by drone (credits: M. Begeja)

182
Figure 90. Second aerial photo made by drone (credits M. Begeja)

Figure 91. Third aerial photo made by drone (Credits M. Begeja)

183
Figure 92. Archival project digitalization and comparisons with the actual survey, ground floor (credits:
H. Nika; M. Lleshi; M. Begeja)

Figure 93. Archival project digitalization and comparisons with the actual survey, ground floor (credits:
H. Nika; M. Lleshi; M. Begeja)

184
Figure 94. 3D Architectural model reworked in rhino v.07 after the survey process (Credits: R. Qose)

Figure 95. 3D structural model reworked in rhino v.07 after the survey process (Credits: R. Qose)

Figure 96. 3D photogrammetric model, processed after the on-site survey phase, in the framework of
BIM modeling

185
Figure 97. BIM Model concept through 3D exploded axonometry models

186
6.2.3.1 Theoretical interpretations, stratification and analysis methodology

The case study selected as part of this study, is one of the blocks of the building of the
Polytechnic University of Tirana “Casa Del Facio-Tirana”, conceived by the Italian architect
Gherardo Bosio, as an integral part of what we know today as "Mother Teresa Square". The
reasons for selecting this building are primarily related to structural regularity, plan and height.
So, it is not an object with complicated geometric features, and its use can also serve to pass in
general for the type of structures rc frames with massive masonry presence, known as "rc frames
with infills", designed and built without criteria of seismic risk protection. Also from the time
of design until today, the destination of use of this object, as a cultural and educational unit,
belongs to the buildings of special importance, which makes it suitable for the objectives of the
thesis, related to the analysis and restoration of cultural heritage.

6.2.3.2 Technical description of the second case study “Casa Del Fascio-Tirana”

The authentic building with the famous grid-shaped facades of the Polytechnic University, built
in the late 1930s, consists of three parts, separated by seismic joints. The two side parts are
symmetrical to each other against the central axis of the building and structurally the same. The
central part, which has even greater height, is analyzed in the general plan up to the level of
modal analysis, while the following is analyzed in specifically only one of the side blocks.

The structure of one of the side blocks of the building consists of four floors, one of which can
be considered partly underground. The type of constructive system is ram reinforced concrete
plans combined with infills. But as a typical building of the '30s, designed by Studio Ferrobeton
in Rome, in accordance with the Italian style of construction of that time, the perimeter walls
are complete and with several layers, the effect of which on the static and seismic behavior of
the structure , is very influential and considerable. On the other hand, the partition walls inside
the building are thin with a thickness of 10 cm and with perforated brick, which are destroyed
very quickly and also the interior partition walls do not extend to the level of the mezzanine and
consequently their effects on the global behavior of the structure. , are negligible and are not
taken into account in seismic and non-linear analysis.

6.2.3.3 Theoretical interpretations of the perimetral masonry, as an essential element in


the structural performance of the building.

Based on the original project obtained in the technical archive, the investigation of photos of the
time of construction, as well as the data recorded during the intervention for the realization of the
southern additions of the structure (in the '70s), "perimeter walls", consist of three layers, two layers
of side bricks (12cm thick), and between a layer of low-grade concrete 26cm thick. These layers are
taken independently because brick and concrete by the way of construction (brick layers were built
after concreting), and the findings on site do not seem to be related to each other. In the structural
intervention mentioned above, the wall between the E and F axes in frame 4 of the structure was
removed in order to connect the existing structure with the South addition.

The total thickness of the perimeter wall throughout the height of the structure is 50cm. The
constructive system of the moment frame type consists of a network of columns with sections which
vary in plan and height of the structure, while the cross sections of the beams, referring to the

187
original designs, are two. The slab is made of reinforced concrete, as a lightweight filling sole
(brick) with a total height of 25 cm, where 5 cm belong to the sole and the rest is composed of
waffle beams 7 cm wide and with (reinforcement 2ϕ10) at the bottom and without reinforcement at
the top as well as bricks.

The service load for which this slab has been calculated, according to the original projects is 350
daN/m2.

6.2.4 The Calculation model

The structural model is worked through the finite element method in Etabs v.19 software.
The structure is modeled with elements of the moment frame type, combined with the walls
which in the role of "infills" play a determining role in the seismic reaction of the building.
In this way, in accordance with the recommendations of the structural program used, the
masonry block is modeled as a two-dimensional element of the type "layered nonlinear
shell", or nonlinear surface element, with two layers, concrete and masonry. Within the
characteristics of the wall layer is considered a common volumetric weight between brick
and mortar, which have a linear fixture interaction between each other.

The connection of the structural elements with the ground, for the columns is a solid
connection (all six degrees of freedom are blocked), while for the walls, their connection at
the base is considered a fixed hinge, because the masonry is supported on the foundation
beams, and in addition to the contact there is no reinforcement to provide the inlay type
connection of these two structural elements.

Figure 98. The Casa del Fascio finite elements model analyzed on ETABS v.19 software

The model selected for the Analysis is the real three-dimensional model. In this model,
structural elements such as beams and columns are presented as linear type elements, which
are easily modeled in any structural program. While the design of partition masonry
presents a considerable difficulty, as they consist of bricks or blocks which vary in specific
weight, strength as well as depend very much on the quality of their construction. In this
188
topic, it is suggested that the partition masonry be modeled in the form of an equivalent
beam, which is in fact the most used in various structural analyzes. While the other walls,
without bricks and mortar in the composition, are modeled in the form of nonlinear layered
elements with nonlinear characteristics for all three components.

Figure 99. Theoretical representation of the equivalent strut of infills (based on the recommendations
received from ASCE / SEI 41-06[31])

Figure 100. Behaviour of rc frames under lateral loads scenarios, first - bare frame (flexible moment
frame), primary or predominance rc bare frame performance under the loads; second - the RC frame +
infills, primary and predominant the truss action, the diagram shows the comparison between the
experimental cyclic response of a rc-frame without infill vs combined one [source: (Tarque & Leandro,
2015)]

Above, in the figure.100 are summarized graphically the reactions of the basic frames,
initially when considered "flexible RC frame", in this case the walls are simply infills
geometrically and considered non-structural, while in the second case is shown the reaction of
the RC frames which in cooperation with the structural infills perform in a combined
manner and to show their characteristics is extracted graphically the comparisons between
the capacities of the two typologies.

6.2.5 Characteristics and data of Materials, investigation on static calculations

Basic data on the materials and geometric dimensions of the structural elements are taken
from the original projects and also from visual findings and investigations in the building.

31
American Society of Civil Engineers. Seismic Rehabilitation of Existing Buildings
189
As we addressed the issue of materials in paragraph 6.1 in the first case study, also in this
case laboratory tests were performed on-site through the assistance of the company "Altea
& GeoStudio 2000", to extract the current mechanical data of the materials. In the case of
the Polytechnic University the focus is on performing tests on concrete material, steel
reinforcement and bricks. The procedure consists of taking a sample of the material in
columns, beams, slabs and walls. Followed by the phase of preparing samples in the
laboratory, performing the relevant tests and obtaining the test results, which will be
summarized in this section below. Cylindrical concrete samples were taken from 3 different
columns and tested in compression, steel samples were taken in 1 of the columns and tested
to tensile strength, while cubic brick samples were taken in a perimeter basement wall
which was tested with compression test.

Table 16. Table of mechanical data of laboratory tests, developed for this case study (Altea & geostudio,
2019)

Material Class/grade Resistance Failure Type of test


Sample image
(MPa) load performed
(kN)
Concrete 250 up to 16.81 72.3 Compression test
350 kg/cm2 results for
cylindrical concrete
sample -1

Concrete 250 up to 28.23 121.4 Compression test


350 kg/cm2 results for
cylindrical concrete
sample - 2

Steel Ç‐3* 177.7 Tensile Test of Steel


Rebar used,
sample-1 of mild
steel reinforcement

White 16.7 258.7 Compression test


brick results for cubic
white brick sample -
1

* From on-site investigations, the steel used in reinforcement is “mild steel rebar”

190
Figure 101. Static calculations applied in the design of the structure (more specifically, the introduction
of the calculation methodology; calculation of bending moment, and dimensioning of the beam section
at frames 2 and 3), (Source: AQTN)
191
Regarding the table.16 during the autumn of 2020, all possible samples of the materials were
taken on-site and then tested in the Laboratory. During the process, special care was taken not
to damage the structure and structural elements of the constituent blocks of the Polytechnic
University of Tirana building. Also, the samples are treated in the laboratory according to
relevant standards. The standards that have been used to perform laboratory tests are:

• For reinforcement samples: UNI EN 10002 & 1065


• For concrete samples: EN 12390 - 3/01
• For mortar samples: EN 1015 - 11: 2001
• For brick samples: ASTM C 67 - 09

Regarding the parameters obtained after the tests performed, we can briefly comment on some
of the conclusions of the report prepared by studio Altea. Referring to the main material in this
building, which is Concrete, has resulted in relatively good quality, which reaches the mark 250
to 350 kg/cm2. From the concrete samples, it was concluded that it was prepared with selected
aggregates. In special parts of the building there are degraded parts and with small cracks mainly
in the cover, this is more evident in the elements of the basement level. According to the
laboratory engineers, they add that one of the reasons for such findings is the presence of
moisture and carbon dioxide released from the boiler of the facility. Also problems related to
the maintenance and insulation of concrete.

Whereas, regarding the geometric shapes data and the relevant specifications for the frame
elements, below is a tabular summary of all the elements of the frame "columns and beams",
which describes in detail the types, position and reductions by floors, the dimensions of the
sections, the data of the fittings, as well as their sketches worked in the model in etabs.

Table 17. Summary table of cross sections of columns and beams, as well as specification of
reinforcement (drawings are worked on etabs)
Elements data Section dimensions Longitudinal bars Stirrups data
Reinforcement and
Type Location bars sketch b (cm) h (cm) Φ As (cm2) Φ s n
(cm)

Basement
Perimetral columns

40 60 6 Φ 22 22.74 Φ6 25 2

192
Ground
Floor

40 50 4 Φ 22 15.2 Φ6 25 2

First
Floor
40 40 4 Φ 18 10.17 Φ6 25 2

Second
Floor
40 30 4 Φ 14 6.51 Φ6 25 2

Basement

55 55 8 Φ 20 25.12 Φ6 25 2
Internal columns

Ground
Floor
45 45 4 Φ 22 15.2 Φ6 25 2

First
Floor 40 35 4 Φ 20 12.56 Φ6 25 2

Second
Floor
30 30 4 Φ 14 6.51 Φ6 25 2

P
(perimetral)

40 50 6 Φ 16 12.05 Φ6 25 2
Beams

B
(internal)
40 45 5 Φ 16 10.05 Φ6 25 2

193
6.2.6 Seismic analysis and Results
Given the above explanation in methodology, historical heritage was initially analyzed to define
seismic parameters and the structural performance. “Modal analysis was conducted in order to
determine fundamental mode shapes and natural frequencies of the structure during free
vibration. The purpose of seismic analysis is to analyse the maximum response of the structure
in each of its important modes of vibrations, which are then summed up in an appropriate
manner view. Modal analysis of the structure included different modes of vibrations in
combination” according to the theory.

Figure 102. First mode of vibration considering the whole complex (Etabs v.19)

Figure 103. Second mode of vibration considering the whole complex (Etabs v.19)

194
Figure 104. Third mode of vibration considering the whole complex (Etabs v.19)

As mentioned above in the methodology, to interpret the results of the modal analysis and to
discuss the periods of self-vibrations, only the western block of the complex has been separated
from the Etabs building for analysis. This block currently belongs to the building of the Faculty
of Electrical Engineering. As it was pointed out, the Bosio building is divided into 3 blocks with
seismic joints, and precisely for this fact the parameters of one of the blocks have been analyzed.
A second reason why one of the blocks has been analyzed at this stage is the detailing and
intensification of the finite elements, the density of the mesh, to increase the accuracy of the
results and to make the model lighter in the software.

Figure 105. First 3 combined modes of vibration according to ETABS.v19 for the case study

195
Table 18. Modal data, frequencies and seismic parameters (ETABS v.19)
Period Frequency CircFreq Eigenvalue
Case Mode
sec cyc/sec rad/sec rad2/sec2
Modal 1 0.716 1.396 8.774 76.983
Modal 2 0.666 1.501 9.4323 88.9675
Modal 3 0.528 1.895 11.904 141.7045
Modal 4 0.233 4.293 26.972 727.49
Modal 5 0.231 4.322 27.1585 737.5854
Modal 6 0.179 5.602 35.1984 1238.924
Modal 7 0.139 7.183 45.1309 2036.7998
Modal 8 0.125 7.987 50.1827 2518.3077
Modal 9 0.112 8.929 56.1026 3147.5005
Modal 10 0.108 9.26 58.1843 3385.4168
Modal 11 0.106 9.417 59.1676 3500.8084
Modal 12 0.088 11.405 71.6566 5134.6679

Table 19. Modal Participating Mass Ratios and period (ETABS v.19)
Period
Case Mode UX UY SumUX SumUY RX RY SumRX SumRY
sec
Modal 1 0.716 0.0013 0.7579 0.0013 0.7579 0.493 0.0009 0.493 0.0009
Modal 2 0.666 0.6345 0.0025 0.6358 0.7604 0.0016 0.448 0.4945 0.4489
Modal 3 0.528 0.1055 0.0007 0.7413 0.7611 0.0003 0.0689 0.4949 0.5178
Modal 4 0.233 1.994E-05 0.1145 0.7413 0.8756 0.3034 3.378E-05 0.7983 0.5178
Modal 5 0.231 0.0963 5.858E-06 0.8376 0.8756 4.667E-05 0.2061 0.7984 0.7239
Modal 6 0.179 0.0118 4.209E-06 0.8495 0.8756 3.995E-06 0.0375 0.7984 0.7615
Modal 7 0.139 2.955E-06 0.1232 0.8495 0.9989 0.191 5.578E-06 0.9894 0.7615
Modal 8 0.125 0.1225 2.219E-05 0.9719 0.9989 1.209E-05 0.179 0.9894 0.9405
Modal 9 0.112 0.0018 0 0.9737 0.9989 0 0.0189 0.9894 0.9594
Modal 10 0.108 0.0262 2.207E-05 0.9999 0.9989 2.487E-06 0.0389 0.9894 0.9983
Modal 11 0.106 1.829E-06 0.0002 0.9999 0.9991 0.0088 0 0.9983 0.9983
Modal 12 0.088 4.733E-05 0 0.9999 0.9991 7.316E-07 0.0016 0.9983 0.9999

Pre-conclusions reffering the Allowed period: [T]= 0.075 * Hb^0.75 (CEN Eurocode 8, Eurocode 8:
Design of structures for earthquake resistance -Part 1: General rules, seismic actions and rules for
buildings, 2008)
First mode: T1=0.716 s > [T] Translation move on X-direction
First mode: T2=0.666 s Translation move on Y-direction and torsion presence
Third mode: T3=0.528 s Pure torsion
Regarding the interpretation of the modal analysis, it is worth noting the presence of torsion and
rotation in the planimetry of the object, since the second mode of self-oscillation of the structure.
Also some aspects that need to be looked at carefully in terms of block displacement, which will
be commented on in the conclusions of the following model.

196
Figure 106. Masonry stress-starin diagrams in the main façade related to the seismic combo (Etabs v.19)

Figure 107. Displacement on the roof, obtained in the framework of static loads (ETABS v.19)

197
Figure 108. Maximum story Displacement of the building related to seismic combinations (Etabs v.19)

Figure 109. Maximum story drifts related to seismic actions x-y (Etabs v.19)

Figure 110. Story shear local force related to seismic actions x-y (Etabs v.19)
198
Figure 111. Story overturning moment of the building related to seismic combinations (Etabs v.19)

Figure 112. Story stiffness related to seismic actions x-y (Etabs v.19)

6.2.7 Non-linear analysis and the theoretical concept of the model

The nonlinear analysis of the second case study is performed through ETABS v.19.1. The
nonlinear properties for frame elements, first columns are assumed to be a plastic hinge
P.M2.M3 and beams component as a plastic hinge represented by bending moment M3
respectively. The axial force P for columns, also, shear force V for beams is considered through
a simple combination according to Eurocode recommendation of dead and live loads
"D+0.3*L", the same combination used in modal analysis.

The wall considered as infills, but also active in its supporting role, and absorbers of shear
forces, is modeled through non-linear characteristics according to the non-linear layered wall
model, specifically with two layers. The first combined layer predicts the stress state in
compression and tension, keeping the normal vertical and horizontal stresses active. The second

199
layer of the panel considers the mechanism of collapse from the crack according to the diagonal
stresses. (Baballeku, 2014)

Figure 113. f.e.m. 3d model of the structure prepared for nonlinear analysis

The mathematical/numerical model must guarantee numerical accuracy in accordance with the
experimental results of analogous cases and in the literature. This model should be able to
predict and simulate the collapse mechanisms needed to represent as accurately as possible the
behavior of the material and structure in each situation.

The static nonlinear analysis "pushover" is carried in both directions of seismic action Push-x
and Push-y. The pushover curves for the case study in x-directions, step by step scenarios of
plastic hinge creation, mechanisms and hinge response are shown below respectively.

Regarding the gradual loading modeling "Push-x and Push-y" this procedure has been followed:
Load case data is selected “non-linear static”, the mass of the structure is also activated at these
loads. Load type “acceleration” according to Ux direction for Push-x and according to Uy
direction for Push-y, load scale factor = 1. Load application control “displacement control”. In
control displacement is used load to a monitored displacement magnitude of 300mm. Monitored
displacement is used the upper floor roof. Related to results saved for nonlinear static case is
selected the minimum number of saved states = 10 steps, and maximum number of saved states
=100steps.

200
Figure 114. Graphical representation of the modeling of possible plastic hinges before performing the
analysis, as well as their positioning towards the edges. Specifically the appearance of hinges in the
sections on the C and A axis

The modeling of possible plastic hinges, presented above in (Figure.114) is realized through the
option “auto hinge assessment data”. The hinge type and their numerical parameters in
general are taken from the tables: “ASCE 41-13 with EC-8 2005, Part 3 acceptance
criteria”[32]. Regarding RC beams, the technical parameters of their hinges are obtained
according to the tables” 10-7 of EC-8.3 (Tab.10-7 concrete beams in flexure/item 1), degree of
freedom only M-3 for beams, horizontal loads applied in both directions “Push-x and push-
y”, deformation controlled hinge load capacity is chosen “drops load after Point E”. Type of
hinges “auto-M3” with relative distance to clear length, specifically 0.1 and 0.9 near the
joints. Referring to the modeling of the hinges on the columns, the technical parameters
are taken according to tables 10-8 of EC-8 for RC columns. Degree of freedom is selected P-
M2-M3. Concrete column failure condition is selected “condition II - flexure/shear”,
horizontal loads applied “Push-x and push-y”. Type of column hinges “auto-P-M2-M3” with
the same relative distance to clear length, 0.1 and 0.9 at the column joints.

32
ASCE standard ASCE/SEI 41-13 “American Society of Civil Engineers”. Seismic evaluation & retrofit of
existing buildings
201
Figure 115. Hinge property data for a selected beam on the left, and for a selected column in the right,
specifically the displacement control parameters, acceptance criteria (plastic rotation/sf) related to
performance levels. General parameters and theoretical behavior of hinges on beams and columns

6.2.8. Results obtained after performing nonlinear analysis

The results used in this section are conceived in 3 main aspects “a- study of the mechanism of
global collapse of the structure, b- capacity curves V-Δ and the procedure to find the
performance points according to Sa-Sd in the ADRS-format[33], c-local analysis of Plastic hinge
response in some of the selected plastic hinges". The transformation of the capacity curve into
the ADRS format is done through modal displacements and floor masses, using the EC-8
(Annex B) procedure and reviewing methodology proposed by Rossetto (Rossetto & Elnashai,
2005).

The theoretical selection of the capacity curve idealization model greatly affects the accuracy
of the performance point. In this study, the idealization / bilinearization procedure will be based
on the principle of equal surfaces or their equivalence. The idealized capacity curve intersects
the real V-Δ capacity curve by creating areas with surfaces below and above the real curve,
which have equal surfaces, which means that the equivalent energy of the two curves must be
equal. The shape of the bi-linearized curve is closely related to the type of structure and the
shape of the V-Δ capacity curve. To increase the accuracy of the performance point
determination, the idealized capacity curve is discretized with a certain number of points before
and after the yielding limit point, which are used as analysis points. Each of these points is
characterized by an Sdi spectral displacement, Sai spectral acceleration, a corresponding Ti
period, as well as by the ductility defined as the Sdi spectral displacement ratio at that point with
the spectral displacement of the Sdy yielding boundary (displacement ductility).

The analyzed results are based especially on the y-direction according to the push-y load and
the fragility of the structure in this regard regarding the geometry in the plan.

33
Acceleration Displacement Response Spectrum format
202
Figure 116. Generation of capacity curve in V-Δ format according to push-x load, captured in etabs.v19

Figure 117. Appearance of plastic hinges in step-20, axis-G, push-y loading in nonlinear analysis

203
Figure 118. Appearance of plastic hinges in step-20, Axis-1, push-y loading in nonlinear analysis

Figure 119. Appearance of plastic hinges in step-20, Axis-3, push-y loading in nonlinear analysis

204
Figure 120. Combination of basic steps according to push-y loading and investigations into possible
scenarios of collapse mechanisms

Figure 121. Generation of capacity curve in V-Δ format according to push-Y load, captured in etabs.v19

205
Figure 122. Column C3H13 and C5H13 hinge response diagrams, according to push-Y load

Figure 123. Column C6H13 and C11H13 hinge response diagrams, according to push-Y load

206
Figure 124. Column C15H13 and C21H13 hinge response diagrams, according to push-Y load

Figure 125. Column C23H13 and C26H13 hinge response diagrams, according to push-Y load

207
Figure 126. Hinge response diagrams selected from nonlinear analysis, according to push-x load
(column C1H13, C9H13 hinge and beam B28H1 hinge response)

Figure 127. Column C12H14, C18H13 nad C7H13 hinge response diagrams, according to push-Y load

Figure 128. Column C25H15, C24H16 nad C28H15 hinge response diagrams, according to push-Y
load
208
6.2.8.1 In-depth analysis in the framework of BIM modeling through “3muri software”,
analysis and investigations into possible masonry collapse scenarios

By the same logic as the first case study was treated, here too it was judged to perform non-linear
analyzes with 3Muri software v.13 academic version. In difference to the first case, non-linear analyzes
were performed here with etabs software, but the focus in this paragraph is to find and specifically
investigate the mechanisms of collapse and harmful cracks only for masonry panels, since the 3Muri
software is specialized for these types of investigations, even modeling the object with the geometric
data explained above, with the same parameters of the materials according to laboratory tests and with
the same loads situations.

Figure 129. Axonometric model worked in 3Muri software, specifically the western block of the
Building complex which currently belongs to the Dean's Office of the Faculty of Electrical Engineering

Figure 130. Axonometric model of the western block worked in 3Muri software, where the
transformation of the panels was performed, through the Mesh process

209
Figure 131. Numerical model of the main facade processed in 3Muri software

Figure 132. Numerical model of the back facade processed in 3Muri software

210
450000
X - direction
400000

350000
C.01 +X /Uniform L.
C.02 +X /Static L.
300000
Base Shear Force [daN]

C.03 -X /Uniform L
C.04 -X /Static L.
250000
C.09 +X /Uniform L.
C.10 +X /Uniform L.
200000 C.11 +X /Static L.
C.12 +X /Static L.

150000 C.13 -X /Uniform L.


C.14 -X /Uniform L.

100000 C.15 -X /Static L.


C.16 -X /Static L.

50000

0
0 1 2 3 4 5 6 7
Roof displacement [cm]
Figure 133. +X and -X direction combined capacity diagrams, processed from 3Muri numerical data

500000
Y - direction
450000

400000

C.05 +Y /Uniform L.
350000
C.06 +Y /Static L.
Base Shear Force [daN]

C.07 -Y /Uniform L.
300000
C.08 -Y /Static L.
C.17 +Y /Uniform L.
250000
C.18 +Y /Uniform L.
C.19 +Y /Static L.
200000 C.20 +Y /Static L.
C.21 -Y /Uniform L.
150000 C.22 -Y /Uniform L.
C.23 -Y /Static L.
100000 C.24 -Y /Static L.

50000

0
0 1 2 3 4 5 6 7 8 9
Roof displacement [cm]
Figure 134. +Y and -Y direction combined capacity diagrams, processed from 3Muri numerical data
211
The next step is to extract and interpret the results of nonlinear pushover analysis through 3Muri
software. Capacity curves are extracted in V-Δ format, specifically combinations of curves
according to X and Y direction, after 24 analyzes performed as follows:

Table 20. Summary table of results analyzed in 3Muri software, focused on the most problematic steps
No
Seism Seismic
α NC α SD α DL
dm/dt Capacity curves
dir. load NC
1 +X Uniform 1.971 1.900 1.703 2.083 Capacity curve / analysis no.01 / +X direction

Analysis-01/Mechanism no.1 /Main façade masonry Analysis-01/Mechanism no.4 /Back façade masonry
/seismic dir.+X/seismic load =uniform plot /seismic dir.+X/seismic load =uniform plot

No
Seism Seismic
α NC α SD α DL
dm/dt Capacity curves
dir. load NC
2 +X Static 1.546 1.450 1.209 1.549 Capacity curve no.02 / analysis no.02 / +X dir.
forces

212
Analysis-02/Mechanism no.1 /Main façade masonry Analysis-02/Mechanism no.2 /Internal hall masonry
/seismic dir.+X/seismic load =static /seismic dir.+X/seismic load =static

No
Seism Seismic
α NC α SD α DL
dm/dt Capacity curves
dir. load NC
3 -X Uniform 2.182 2.105 1.822 2.416
4 -X Static 1.665 1.564 1.217 1.670 Capacity curves
forces

Analysis-04/Mechanism no.1 /Main façade masonry Analysis-04/Mechanism no.2 /Internal hall masonry
/seismic dir.-X/seismic load =static /seismic dir.-X/seismic load =static

No
Seism Seismic
α NC α SD α DL
dm/dt Capacity curves
dir. load NC
5 +Y Uniform 3.792 3.682 2.104 4.987
6 +Y Static 3.139 3.001 1.575 3.630
forces
7 -Y Uniform 2.720 2.606 1.054 3.046
8 -Y Static 2.997 2.866 1.530 3.427
forces
213
9 +X Uniform 2.101 2.027 1.830 2.298
10 +X Uniform 2.054 1.983 1.842 2.244

No
Seism Seismic
α NC α SD α DL
dm/dt Capacity curves
dir. load NC
11 +X Static 1.129 1.033 0.910 1.129 Capacity curve no.11 / analysis no.11 / +X dir.
forces

Analysis-11/Mechanism no.1 /Main façade masonry Analysis-11/Mechanism no.4 /Back façade masonry
/seismic dir.+X/seismic load =static /seismic dir.+X/seismic load =static

No
Seism Seismic
α NC α SD α DL
dm/dt Capacity curves
dir. load NC
12 +X Static 1.552 1.455 1.201 1.549 Capacity curve no.12 / analysis no.12 / +X dir.
forces

No
Seism Seismic
α NC α SD α DL
dm/dt Capacity curves
dir. load NC
214
13 -X Uniform 2.226 2.145 1.793 2.470
14 -X Uniform 2.175 2.099 1.853 2.400
15 -X Static 1.688 1.585 1.204 1.693
forces
16 -X Static 1.647 1.546 1.224 1.653
forces
17 +Y Uniform 2.265 2.254 2.154 2.730
18 +Y Uniform 3.180 3.097 1.918 4.145

No
Seism Seismic
α NC α SD α DL
dm/dt Capacity curves
dir. load NC
19 +Y Static 2.268 2.184 1.595 2.553
forces

Analysis-19/Mechanism no.5 /West side façade Analysis-19/Mechanism no.11 /East side façade
masonry /seismic dir.+Y/seismic load =static masonry /seismic dir.+Y/seismic load =static

No
Seism Seismic
α NC α SD α DL
dm/dt Capacity curves
dir. load NC
215
20 +Y Static 2.430 2.333 1.467 2.731
forces
21 -Y Uniform 2.689 2.641 1.917 3.446
22 -Y Uniform 2.876 2.813 1.905 3.720
No
Seism Seismic
α NC α SD α DL
dm/dt Capacity curves
dir. load NC
23 -Y Static 1.070 1.018 0.894 1.945 Capacity curve no.23 / analysis no.23 / -Y dir.
forces

Analysis-23/Mechanism no.5 /West side façade Analysis-23/Mechanism no.11 /East side façade
masonry /seismic dir.-Y/seismic load =static masonry /seismic dir.-Y/seismic load =static

No
Seism Seismic
α NC α SD α DL
dm/dt Capacity curves
dir. load NC
24 -Y Static 1.047 0.991 0.985 2.253 Capacity curve no.24 / analysis no.24 / -Y dir.
forces

216
Analysis-24/Mechanism no.5 /West side façade Analysis-24/Mechanism no.11 /East side façade
masonry /seismic dir.-Y/seismic load =static masonry /seismic dir.-Y/seismic load =static

According to the 3Muri software protocol, 24 analyzes were performed, in the framework of nonlinear
pushover simulations. The analyzes were performed in seismic combinations according to eurocode-8
and in two general directions ± X and ± Y. From the initial table generated in the program, the structure
shows a satisfactory performance in the global aspect, but several steps have been identified where the
structure shows problems in reaction, also masonry parts with pronounced fragility against these actions,
which are part of the discussion for further investigation. . We can distinguish the analysis no.11 in the
+ X direction where the structure shows weakness mainly in the masonry of longitudinal facades, while
the analysis no.23 / 24 in the -Y direction where the problems are localized mainly in the masonry of the
transverse facades.

217
6.2.8.2 Efficient intervention strategy, aimed at increasing the seismic performance

After the situation presented above by identifying the most fragile areas of the masonry, at this
stage it is continued with an retrofitting strategy. Also in this case the proposals are conceived
in such a way that they do not affect the aesthetics of the building facades, but at the same time
significantly increase the performance of the structure. The FRCM reinforcement is
recommended, where this reinforcing layer is added to the panel in its inner part. The selected
material for simulations is "Mapegrid G220, Mapei" with the following data:

Figure 135. Physico-mechanical parameters and characteristics of the recommended reinforcement layer
"Mapegrid g220", according to the database used in 3Muri software libraries

Table 21. Technical data according to Mapei quality standard (Mapei, 2019)
Technical data

Tipo di fibra: fibre di vetro A.R.


Contenuto di ossido di zirconio (ZrO₂) (%): 17
Grammatura (g/m2): 225
Dimensione delle maglie (mm): 25 x 25
Application data

Resistenza a trazione (kN/m): 45


Modulo elastico (GPa): 72
Area resistente per unita di larghezza (mm2/m): 35,27
Spessore equivalente di tessuto secco (mm): 0,035
Allungamento a rottura (%): 1,8

218
The application of reinforcement is asymmetric in this case, and is configured in such a way as
to test and increase the effectiveness of the recommendations for intervention. Always with the
logic of maintaining the symmetrical distribution of masses and rigidities of the structure.

Examining the most fragile areas of the masonry, the logic of the interventions is based on the
reinforcement of the masonry with FRCM type Mapegrid G220. This intervention has been
applied in the main facade, north direction, which corresponds to panel no.04 in the software,
only on the ground floor. FRCM was also applied on the south façade from behind,
corresponding to panel no.02 at ground floor level. To avoid the mechanism of collapse, seeing
from the simulations that this intervention is not enough in the back facade, two pairs of steel
bracing systems have been added with the data presented in table 20. Also in the side, east and
west facades, corresponding to panels no.01 and 03, FRCM reinforcements and two different
steel-bracing configurations were applied to avoid the possible collapse mechanism found by
the investigations. The general schemes for configuration of interventions are given in the table
below:

Table 22. Graphic representation of configurations in plan and height of reinforcing elements
* Positioning of the panels where the intervention was applied,
** Data on their geometric configuration

Plan configuration and


positioning of FRCM
intervention

Plan configuration and


positioning of Bracing
systems intervention

219
Bracing system application and configuration Bracing system application Bracing system application
in panel no.02 of the back façade /south side and configuration in panel and configuration in panel
no.01 of the side façade no.03 of the side façade /east
/west side side

Numerical data and technical parameters of Numerical data and technical parameters of
profiles, used on the southern longitudinal profiles, used on side facades, east and west dir.
façade

220
• Results obtained after numerical applications and simulations to find effective methods of
reinforcement interventions

Table 23. Summary table with data obtained after reinforced structure simulations, value comparisons
Before application After reinforcement application
Analysis no.11 +X/Static load/panel no.04, 02 Analysis no.11 -Y/Static load/panel no.11
No. Seism Seism. α NC α SD α DL dm/dt No. Seism Seism. α NC α SD α DL dm/dt
. dir. load NC . dir. load NC
11 +X Static 1.129 1.033 0.910 1.129 11 +X Static 2.77 2.69 1.78 3.294
forces forces 0 2 2

T*=0.606s T*=0.474s
Panel of local mechanism model / panel.04 /main Panel-04 / verified mechanism model /reinforced
façade

Panel of local mechanism model / panel.02 /back Panel-02 /verified mechanism model / reinforced
façade

Before application After reinforcement application


Analysis no.23 -Y/Static load Analysis no.23 -Y/Static load
No. Seism Seism. α NC α SD α DL dm/dt No. Seism Seism. α NC α SD α DL dm/dt
. dir. load NC . dir. load NC
23 -Y Static 1.075 1.037 1.160 1.081 23 -Y Static 1.74 1.67 1.67 2.842
forces forces 1 1 1
Capacity curve Capacity curve

221
Panel of local mechanism model / panel no.01 /west Panel verified mechanism model / panel no.01 /After
side façade /before intervention intervention

Analysis no.24
Panel of local mechanism model / panel no.03 /west Panel verified mechanism model / panel no.03 /After
side façade /before intervention intervention

222
6.2.9 Case II, Conclusions and recommendations

Regarding the basic parameters of the modal analysis evaluation, the periods of self-oscillations
of the structure show some problems of exceeding the allowed parameters. The calculated
allowable period of the structure is [T] = 0.612s while the period T1 = 0.716s. This can be
considered somewhat problematic, also considering the fact of the presence of partial torsion
present in the second oscillation mode. The same phenomenon is observed even if we analyze
separately from the complex, only one of the side blocks, also there is the presence of a torsion
in the first two modes, although with small values this is considered problematic for a structure
of such importance.

The results of seismic analysis have shown the most critical section of the building are the two
joint areas between the 3 blocks, as there are differences in structure in height, although the
presence of joints in the design facilitates seismic performance. In these areas, after several
interventions at different times, some concentrations of stress are created. This type of stress
does not create problems of structural stability but must be taken into account in the local plan,
of the vulnerability of the infills.

In this case study after the analysis performed, it was shown that referring to the seismic demand
according to KTP-89/2 still in force in Albania, the expected damages range from moderate to
large damages, referring to the seismic performance levels. While referring to the seismic
demand based on studies conducted after the 1990s (specifically seismic demands referring to
Eurocode-8), RC moment frame with the presence of infills masonry built in the late 1940s have
a very high probability of suffering very serious damage and occurring in "collapse threshold"
in certain scenarios. Compared to other analogous researches for similar structures in the
literature, a great similarity is found in the estimation of the moment of destruction of the
structure, but in relation to other levels of vulnerability the changes are large, this is attributed
to changes in the ways of indexation of vulnerability levels.

The displacements show a good reaction of the structure in the longitudinal plane oriented
according to east-west and a slightly more fragile reaction in the transverse direction oriented
north-south. The occurrence of drifts in significant values in relation to the seismic action in the
y-direction can also be considered for later studies or structural retrofitting strategies.

In conclusion of this case we can say that the capacity spectrum method that is used, offers a
practical and well-balanced way between the time spent and the accuracy provided. Considering
more factors that affect the capacity of the structure as well as the wider scope of the study even
for structures with specific configuration characteristics, are the goals of the development of this
study beyond this topic. Also increase the accuracy of determining the capacity spectrum, but
also indexing through simulation of damage to existing structures with the help of programs that
implement BIM and more.

223
6.2.9.1 Interpretations related to Nonlinear static analysis "Pushover"

Static non-linear analysis, Pushover is one of the approximate method used to evaluate the
existing and old structures. The methodology is used to evaluate in depth as well as in
performance based seismic design. Nonlinear static analysis can be considered an improvement
compared with the classic seismic or modal analysis since it allows inelastic behavior of the
structure and elements. The method is simple to implement especially with rc-frames or rc-
frames + infills, also provides more information’s about strength, target displacements,
performance point of existing structures, collapse mechanisms and scenarios, also the ductility
of the structure as well as the seismic demand.
For the evaluation of seismic performance, one of the basic parameters is the "Target
displacement", which in this case is theoretically analyzed in the y-direction, described as the
most fragile position of the structure (referring to the longitudinal rectangular geometric
configuration). So, dt* identified according to the Y-direction, respectively according to the
Push-Y loading model, in numerical value is “dt*=0.0119m”, obtained graphically from the
point intersection of the period T* with the bi-linearized capacity curve, which is converted
according to the ADRS format[34].
From the investigations in the global aspect of the structure for possible scenarios of collapse
mechanisms, we notice that one of them is the creation of plastic hinges at the upper ends of the
first floor columns nodes, near the G-axis in the eastern position of the block near the seismic
joint. At this level is the largest floor height 7.4m referring to the levels of the structure.
Theoretically the high floor height versus 2 other floors with reduced height, favors this
phenomenon and can activates the soft-story phenomenon, however in this case we must be
conservative in achieving such conclusions, as the masonry infills greatly affects the
performance of the frame and increases the factors resistant to this phenomenon.
However, from the analysis, interpreting the scenarios of the collapse mechanism, we are able
to identify and locate the most fragile and weak part of the RC structure, especially the 4
columns where the plastic hinges are created. Exactly, this is the area where we can conceive
the beginning of a possible scenario of the collapse mechanism of the building, in the future.
Also in the given proposals the focus of the retrofit strategy should include in a special way the
g-axis and this group of columns. For giving proposals for interventions and consolidation
approaches we already have a clearer set of data related to the analyzes performed above.
Regarding the nonlinear verification procedure, such kind of checks seem to be more related
with reality aspects if done rigorously with the finite elements model. This model allows to take
into account the effects of the mutual link between elements, materials layers and nonlinearity,
the mutual collaboration between walls of the frame, and redistribution of stresses and strains
in a way easily guessed that predicts and calculates real practical consistency of the building.

34
ADRS - Acceleration-Displacement Response Spectrum, format used for converting diagrams
224
6.2.9.2 Proposals for local interventions, in terms of seismic readjustment of the structure

Let's analyse the problems noticed especially in the nonlinear analysis, where are identified a
group of columns (in the axes "g-1, g-2, g-3 and g-4", at the level of the first floor) in which
plastic hinges are created (this was noticed between step-17 to step-20 push-Y). This makes us
carefully review their performance in terms of interaction with the wall. Since the filling
masonry in this case is massive with a considerable thickness, it also has a structural role, then
one of the recommendations for the best retrofit strategy is to separate the RC frame from
masonry panels. A recommended detail is shown in figure 138.
To move on to the recommendations, a review was conducted on the relevant investigations into
this issue. The study of Tarque et al is reviewed, and in figure.136. is shown the mechanism of
collapse of the masonry panel as infills within the RC frame (Tarque & Leandro, 2015), taken
from study and graphically shown the results of laboratory tests for the respective models of
panels, simulated. Crack pattern between masonry and infills (also, positive and negative stress
distribution) are also shown, according to the third loading cycle. Regarding this analysis of
mechanisms we must be clear with the typologies of local damages, in the possible scenarios of
the case study. So, based on these theoretical and practical issues the following interventions
aimed at seismic readjustment can be recommended, mainly in the local plan of the structure.

Figure 136. Crack patterns of the masonry-infilled frame test specimen and crack widths in the model
during the third cycle of loading (positive and negative) (Tarque & Leandro, 2015)

225
Figure 137. two typical local failure scenarios for RC-frames + infills, (first) RC-frame failure mode,
shear + sliding including diagonal cracks; (second) corner crushing + diagonal compression failure mode
(Asteris & Sophianopoulos, Mathematical Macromodeling of Infilled Frames: State of the Art, 2011)

To maintain their in-plane load-bearing capacity, the infills walls should not collapse due to
forces out of planes. The "out of plan" collapse mechanism is a condition of the "live safety"
performance level. Most design codes have long avoided considering the structural contribution
of infill walls, mainly as a result of: (a) the problem being overlooked because it is not fully
understood, due to the high number of variables and accumulated uncertainties; (b) the behavior
of the infills masonry and its combination and co-operation with the RC-frame depends
predominantly on the geometry of the frame and the type of infills wall, which necessarily reacts
significantly differently in different seismic locations, with different seismic intensities. (Tarque
& Leandro, 2015)

Five categories of in-plane local-failure mode referring to Asteris theory, are identified and
summarized as follows: (a) Frame mechanism, consisting in the formation of plastic hinges in
the beams and columns near the joints; (b) sliding shear mechanism, the infills panel experiences
horizontal sliding through multiple joints; (c) diagonal cracking mechanism, a diffuse cracking
along the wall panel compressed in diagonal way. It theoretically presents a diagonal pattern
along the mortar joints; (d) diagonal compression mechanism, crushing of the panel geometric
center. This mechanism usually occurs in slender infills type, placed eccentrically according to
the axis of the RC frame, combined by out-of-plane deformations; (e) corner crushing
mechanism, consists of crushing in an overloaded corner part of the infill masonry related to a
biaxial compression state. This occurs in that cases when the structure has a weak infill panel
linked by strong frame. (Tarque & Leandro, 2015) All of these local failure mechanisms, which
were briefly summarized above, are graphically shown in figure.136.

226
Figure 138. Suggested “masonry infill-frame” separation detail (Hollings 1981); taken from the paper
(Charleson & Vesho, 2020)

After theoretically summarizing all the local mechanisms of reactions between rc-frame and
infills, also after finding the results of the simulations we can analyze this intervention. This
detail prevents the "infills panels" from creating a diagonal compression area “pier element”,
also experiencing diagonal tension area “tie element”. These areas with high stress
concentrations would inevitably lead to residual deformations in the wall panels, converted into
significant cracks and fractures, always when unfavorable situations with simulations of strong
seismic events.

Columns support and limit the infill panels work against side lateral loads (shear forces).
However, this old “solution is not efficient. The presence of the masonry stiffens and strengthens
the beam in the same time, also, prevents normal length plastic hinges forming at beam ends
during an strong earthquake shaking. Instead of distributed cracking along beams up to twice
their depths, one considerable wide crack shape will form at column faces, greatly limiting the
ductility capacity of the hinges at the nodes” (Charleson & Vesho, 2020).

In another scenario we must emphasize the reverse case when the wall panel turns into a problem
for rc-frame, emphasizing that the two elements have different behavior and performance
against seismic events. The wall absorbs large shear forces and performs rigidly, while the frame
moment has flexible reaction. The rigid behavior of the wall and the confrontation with the
significant displacements of the frames cause collisions and damages of the frame joints at the
meeting points. Solid wall-frame bonding techniques have proved problematic in many
analogous theoretical cases, but also appear troubling in the results of this study.

227
Proposals on local interventions

After browsing the relevant literature, related to the recommendations of retrofit strategies for
improving the seismic performance of masonry, will be summarized some general suggestions
for improving out-of-plane performance, as below:
• strengthening the masonry using “reinforced concrete overlays”;
• strengthening the masonry using “fibre reinforced polymer (FRP)”, especially carbon
fibber’s strips (CFRP);
• overlays or near surface mounted F.R.P. strips (should be noted that FRP strips will be
required on both sides, according the local failure mechanisms evidenced by
simulations);
• strengthening the masonry using “engineered cementitious composite (ECC)” shotcrete
overlays;
• removing or replacement the infill wall, when required as appropriate (in cases when
retrofitting of the frame will be performed; or in cases when the wall causes serious
problems to the frame, in this case it is recommended to replace the wall with a
resized/redesigned panel according to the simulated model ne software).

Suggestions “are also made to improve in-plane performance that involve strengthening the
infill, but also include those already mentioned above. These suggestions should be done and
implemented very carefully, accompanied by a detailed project, done after many simulations
(before and after the intervention), to avoid damage to the primary reinforced concrete frame
members of the case study.”

6.2.8.1 Conclusions regarding the analysis and investigations applied in 3Muri software,
recommendations for possible effective interventions

The next step is the analysis of seismic vulnerability performed with 3Muri software, checking,
as a first and target step, that the value of activation of local mechanisms is not achieved (in
every investigation performed); then linking it to the assessment of the overall behaviour of the
structure, dealt with in chapter 6.2.7, by performing a check and parameter comparisons. The
method was based on pushover nonlinear analysis results obtained on the basis of "3Muri macro-
element models", which uses equivalent models with a schematic of equivalent frames. From
the engineering experience of use, it seems that it is quite suitable for the description of this type
of structures due to the possibility of characterizing seismic belts, rigid floor slabs and giving
the possibility of masonry configurations in the presence of columns.

Even with this model, after performing 24 nonlinear pushover analysis, a table with detailed
data is drawn which are found in paragraph 6.2.8.1 of this chapter. The results are satisfactory
for this building, while from the local investigations of each step, some collapse mechanisms
have been localized similar to those captured in the model in ETABs, specifically analysis no.11
+ Xdir. and no.23 -Ydir. But if we compare with the model in Etabs here the masonry has higher
expectations to be closer to the real model, considering all the equivalences performed by 3Muri.
Another important finding is the difference in the value of the self-vibration period between the
two models, where we have a lower value found in the 3Muri macro-element model versus the
period verified in the ETABs model. This can be interpreted theoretically correctly in the 3Muri
228
model, which considers masonry as a key structural element, compared to ETABs model which
mainly consider masonry as infills, although it is modelled with layers with nonlinear data.

Later, the Pushover simulations in the building, represented in paragraph 6.2.8.1 has led to
propose and apply two different reinforcement solutions for the masonry initially and the
combined structure later. Respectively two-way steel strip reinforcement jacket, e type FRCM
Mapegrid g220; the second solution combination between reinforcement with FRCM + Steel
bracing system (this case was applied as it was not enough just to rehabilitate the masonry). The
detailed parameters and numerical data generated in paragraph 6.2.8.2 show a significant
increase in local capacity by avoiding the mechanisms of local collapse, also globally by
significantly increasing the rigidity and strength of the structure.

In conclusion, in this case it was intended to provide the appropriate tools for an assessment of
the global structural and local behaviour of the most fragile elements of the building,
emphasizing the criticisms of automatic calculation methods and instructions.

229
6.3 CASE III - Analysis of “Ex. Opera Dopolavoro Albanese” University of Fine Arts today

On the west side of Mother Teresa Square was the Palace of the Albanian Opera of the
Unemployed, designed by Italian architect Gherardo Bosio between 1939 and 1940. The T-
shaped planimetric system suffered “the composition of the large space of the theater with the
stake longitudinal offices. Bosio had previously studied another typological imposition: a block
in the courtyard with high porches on the façade of the square, positioning the theater space
always at the back but parallel to the square. In the final version of the project, he decided to
rotate” the theater and create a very compact facade over the square, in order to oppose with its
mass the permeability of the building architecture. At the back was highlighted the volumetric
composition of the plastered facade bodies on a stone plinth, interrupted by stairs.

Figure 139. Opera Dopolavoro, elaborate facade fragment accompanied by the layout of the boulevard

The main façade had a heavy shade with its rhythmic cracks and cladding with polished
travertine panels. While in the center, in harmony with the upper porches of the building, a crack
opens in the facade with an entrance porch with five buildings. The articulation of mural plastic
is completely absent, perhaps this is exactly the building that departs most from the language of
the ministries of Skanderbeg Square. Instead of different planes of alignment of the façade,
230
movements of clean masses are clearly preferred, not clearly hierarchically arranged, almost
abstract in their serial language of cracks.

Denial of the dual-functionality of the façade in favor of a hidden depth of mass, the strong
climbing behind the ground that becomes the architecture itself, the verticality of the cracks that
clearly highlight the range of interiors, require a modern language "different" from the dream
white of the Modern Movement. Bosio is certainly a modern in the conception of the project,
belongs “to the generation of integral architects, coming out of the schools of architecture,
influenced by the thought of Giovannoni and Piacentini but who also look closely at the cultural
revolution” that is taking place was taking place. In fact, he is one of the founders of the "Tuscan
group", leaving it later in 1933 due to disagreements with Giovanni Michelucci.

Gherardo Bosio, already a graduate of civil engineering, attended the High School of
Architecture in Florence, but due to many professional commitments did not graduate, however
in 1933 he entered the same school as an assistant in charge of drawing and composition. He is
an integral architect in the practical sense of the Giovanni concept, he dealt with new
architecture, restoration of cultural heritage, interior furniture, design, urban planning, without
ever losing sight of the unity of design thought on buildings. Today the building has the function
of a campus for the University of Fine Arts of Tirana. Over time the west side has expanded
doubling the area of the building.

Figure 140. Sketch-concept conceived by Bosio for the design of the building (source: AQTN)

The architectural style belongs to Italian rationalism. The building consists of several blocks
and in the main facade there is a main portico. The rhythm of the windows varies according to
the first, second, third orders. The windows have a quadrangular frame protruding beyond the
contour of the wall. The concert hall has architectural and structural values, related to its size
and construction technology at that time.

231
6.3.1 The process of surveying, photographing and digitizing the archival project

This process just like in the previous two case studies, has been developed very carefully and in
coordination and cooperation with the Cultural heritage restoration subject of Polis University.
The projects received in the technical archive were analyzed, then a 3-week phase of sketching,
monitoring and on-site photography took place, where the lecturers of the subject together with
the students of architecture class and civil engineering class successfully completed this phase.
Investigations were also carried out on reconstructions, retrofit interventions, or additions to the
Building. Then the process of orthogonal photography with a drone was performed and then
digitalization through the process of photogrammetry. At this stage, the orthogonal facades of
the building were excavated, and carefully analyzed on each intervention. The photo album
below shows fragments of this process, mainly the photographing of the object.

Figure 141. Main plan of the building, Bosio drawings (source: AQTN)

Figure 142. Side view of the building combined with main section-cut (source: AQTN)

232
Figure 143. University of fine arts Main façade (source: AQTN)

Figure 144. Two secondary section cuts of the building (source: AQTN)

Figure 145. Back facade of the building (source: AQTN)


233
Figure 146. Survey of the main façade through forogrammetry; sketching of marble panels; and
extraction of the complete model of the southern façade after filling in the missing parts

234
Figure 147. Architectural Survey process, facades, doors, windows and 3d-model reworked (Credits: K.
Guraleci)

235
Figure 148. Details and photo collage of the exterior and interior of the building (Credits: H. Bendaj)

236
Figure 149. Architectural details extracted from the on-site survey process. Marble staircase detail,
decorative door and frame detail, parapet detail, section-cut atrium detail, decorative window and frame
detail, atrium sketch and interior of the building

237
Figure 150. Architectural plans, sections & facades, re-worked in accordance with original archival
drawings, part of the documentation and digitalization of archival projects (elaborated by the author)

238
Figure 151. Analysis panel on the north façade, investigations on a group of degradation issues, part.01
(credits: Guraleci & Vrenozi)

239
Figure 152. Analysis panel on the east main façade, investigations on degradation issues, part.02

240
Figure 153. Analysis panel on the north façade, investigations on a group of degradation issues, part.03

241
Figure 154. Theoretical concept of the BIM model for this case, through Exploded Axonometry

242
6.3.2 Theoretical interpretations of the structural concept of the building

The central block, in front of "Mother Teresa" square, consists of unreinforced masonry
structure, with 2 different thicknesses according to 2 levels. Masonry up to level +1.10 which is
considered the visible upper level of the foundation, has a thickness of 72cm. Above this level
the wall thickness is uniform with a thickness of 45cm. The wall is structural and alternates with
holes which serve as windows of the building. Vertical wall panels are continuous, and in
engineering analysis are considered "Pier" elements, so in the equivalent model in the software
have the role of vertical columns.

Wall panels over window openings are structural elements which also consider bending aspects,
so in modeling they are considered "spandrels" elements. The foundation typology of this block
are "massive continuous stone foundation", which follow the shape of structural walls with a
thickness of 72cm. Depth of foundation is in the quota -1.00m below ground level. Building
slabs are an essential element in the conception and configuration of the supporting structure.
Slabs are considered by the design as solid elements of the horizontal plate type, in the model
they are shell type with a thickness of 18cm. Slabs are supported on the contour of the masonry,
oriented in the shortest direction and are the main element in withstanding horizontal forces,
emphasizing seismic forces. They are elements with considerable rigidity for the building and
play a key role in the seismic performance of the building.

After the process of surveying and analysis on the structure of the back block, where the concert
hall is located, we have other interesting features. Concert hall has geometric dimensions in the
plan "29.30m x 15.70m", and dimensions in height of 12.00m. The vertical retaining structure
consists of the same brick wall with a thickness of 45cm, combined with concrete columns with
dimensions 45x45cm. Inside the hall there are some transverse walls with a thickness of 25cm,
which also serve as a rigid rib for the vertical structure. Regarding the analysis of the cover, it
is realized with a "cassette slab or big waffle slab", ie a shell type sole, placed on reinforced
concrete beams which are positioned in two directions. The beams of this floor are placed every
1.8m from each other. The dimensions of these beams under the slab are 45cm x 70cm. The slab
is placed and fixed to the contour of the wall, and the waffle spaces are empty.

Figure 155. Re-conception and analysis of the structural project according to Bosio (souce: AQTN)

243
Figure 156. Seismic gap detail between two blocks of the building (left), The 2-storey part that makes
the connection between the main block A and the concert hall in block B (right) (source: AQTN)

From the analysis of the project of G. Bosio, it is clearly understood his engineering logic, for
dividing the blocks with a seismic joint in the middle. This is very important as it gives freedom
of movement to two blocks during a seismic event, where it should be noted that block A near
the square "Mother Teresa", has a horizontal longitudinal rectangular configuration, while block
B of the concert hall has a vertical longitudinal configuration and normally their reactions are
different during a seismic event. For further findings and interpretations are made after analysis
and model simulations in the following software.

Figure 157. The full complex of the University of Arts campus today and the relevant legend according
to the time of construction. Orientation diagrams on block stratification (Credits E. Mucollari, K. Como)

244
Figure 158. Photo taken during the construction of the campus of the University of Arts (source: AQTN)

6.3.3 Concepts on the methodology of the calculation F.e.m.[35] Model

In this method the structural system is discretized in equivalent deformable horizontal and
vertical frames, connected by solid joints. The method is preferred compared to micro-modeling
approaches due to the complexity of the nonlinear characterization material and the numerous
computational parameters. Most macro element modeling approaches make general theoretical
assumptions about off-plane collapse mechanisms, a common mode of collapse in existing
masonry structures. Idealizations in modeling the action of rigid slab in the horizontal structural
system are also quite empirical. The following analysis examines the results of macro element
modeling and analysis, particularly in terms of global capacity and damage mechanisms,
masonry crack investigations, and collapse scenarios.

The model used in the Etabs v.19 program is two-dimensional, capable of simulating the
planned behavior of masonry panels. The wall is modeled as a vertical shell element with 2
thicknesses at different levels according to the project. Meanwhile, the panel is converted into
vertical blocks of the “pier” type, which receives the static vertical load, and horizontal
“spandrel” elements type over the windows, where the bending is taken into consideration. The
slabs are modeled as horizontal shell elements in bending, with a thickness of 18cm. The roof
of Concert hall is modeled with a horizontal shell and under this layer are placed cross beams
in two directions with dimensions 45x70cm, every 1.8m from each other. Under the foundations
are placed springs with the simulation of the ground-foundation interaction. The modeling of
the finite elements is done manually and the dimensions of the finite element are 1x1m, while
generating of finite element MESH [36] is done automatically in the program. Initially the model
was fully simulated, considering all the component blocks of the building. At some specific
stages of seismic analysis, especially when analyzing stress-strain distribution in wall panels,

35
F..E.M. – Finite element modelling, is a method for numerically solving differential equations arising in civil
engineering and mathematical modeling of elements
36
Mesh process – used to subdivide the CAD model into smaller domains called elements, over which a set of
equations are solved. These equations approximately represent the governing equation of interest via a set of
polynomial functions defined over each element.
245
the model is considered separate. This is not a limitation, but is considered as such to focus on
the relevant points where data are required for analysis.

Only the reaction of the main block with a façade oriented by Mother Teresa Square was
analyzed in the etabs. Since the blocks are separated by seismic joints, the reaction of this block
can also be investigated simply, considered separate from the other blocks of the complex. In
this modeling the same methodology is followed according to the model F.e.m. explained above.
We emphasize that in models simulated we have some limitations. These restrictions consist of
not being included in the analysis of buildings near this case-study. It is about buildings and
other blocks, part of the university campus built in later periods. These buildings are considered
only in the architectural aspect of the stratification analysis over the years.

Figure 159. 3D F.e.m. model on ETABS v.19 related to main building of University of fine Arts (author)

6.3.3.1 Modeling of piers

In the proposed model, which was explained above is considered the Pier collapse mechanism
shown in (figure.160) and a biaxial interaction between the load as the axial force and the
bending moment (NM), including the forces axial and shear force (NV) which have also been
considered.

Panel bending behavior: Pier bending behavior is expressed in terms of a moment curvature
relationship, starting from the one-axial law of stress-strain diagram shown in (figure 162).

Shearing behavior: Pier shear behavior is modeled as elasto-plastic (figure 162), with the
ultimate shear Vu taken as the minimum between the failure for diagonal cracking Vd and the
failure for sliding Vs.

246
Figure 160. Piers failure mechanisms. Diagonal cracks, sliding and bending failure

Figure 161. Stress-Strain relationship diagram in compression. Stress-strain diagram for Uncracked and
cracked masonry panel cross section

Figure 162. Moment curvature and Shear displacement curves equivalent for piers panel

6.3.3.2 Spandrels modelling

The behavior of spandrels is a very essential aspect in equivalent frame models of a masonry
structure. Spandrels “play a fundamental role in the seismic behavior of masonry, as they model
the joint between the panels and the pier boundary conditions.”

There are “many experimental results which are of great importance, to determine the behavior
of spandrels, which is significantly different from that of vertical elements, because under
seismic loads, spandrels are subject to shear force and bending and from the most important
aspects , they are subjected to a very small, negligible axial force. The collapse of the spandrel
usually occurs according to two mechanisms: oscillation and diagonal rupture.” Slip collapse, in

247
fact, “cannot occur due to various phenomena occurring in the area between the end parts of the
spandrels and the adjacent Pier. Failure cannot occur given the very low axial forces acting.”

6.3.4 Tabular summary of mechanical data of materials related to the third case study

By the same logic as in paragraph 6.2.5, also in this case laboratory tests were performed on
site. Cylindrical concrete samples were taken, which were tested in compression, steel samples
which were tested in tensile strength, and white cubic brick samples were taken in 4 positions
on the perimeter wall of the basement which was tested by compression test.

Table 24. Table of mechanical data of laboratory tests, for third case study (Altea & geostudio, 2019)
Type of test
Resistance Failure load Sample image
Material performed
(MPa) (kN)
Concrete 28 Compression test
results for
cylindrical
concrete sample-1

Steel for 346.85 Tensile Test of


mild rebars Steel Rebar used,
sample-1 of mild
steel rebars

Silicate 18.35 276.4 Compression test


brick results for cubic
white brick
sample -1

* Also in this case after the investigation, the steel used in reinforcement is “mild steel rebar”

6.3.4.1 Data on the dimensions of the basic elements, interpretations on structural


solutions

Ground floor and first brick wall with thickness t = 72 cm.


Upper floors brick wall t = 45 cm.
At the top of the masonry of each floor there are concrete belts (70x20) and (60x20) depending
on the thickness of the wall. The slabs are thicker. (h = 18cm)

To be mentioned is the structural solution of the concert hall, which is a space 27 meters long
and 17.5m wide. This space has been solved by the engineers with a cassette slab, consisting of
248
primary and secondary beams with a depth of 60-80cm, with empty spaces between them of
80x80cm. This can be considered very innovative for the time and is modeled as a "big waffle-
slab", with the parameters explained above in the diagram and numerical data.

6.3.4.2 Summary of spectral data used in the seismic analysis

A cceleration(m /s^2)
4e-1

3e-1

2e-1

1e-1

P eriod (s)
00.0 1.0 2.0 3.0
Figure 163. Diagram of design spectrum used for seismic analysis and simulations

Basement general data used in the software:


Site: C
Spectrum type: 1
Direction: Horizontal
Behavior factor: 2.000

Elastic Spectrum used parameters:


Acceleration: ag=0.270
Damping: ζ=5.00 %
Damping correction: η= [10/(5+ζ)]0,5 =1.000
S =1.150; β =0.200; TB =0.200; TC =0.600; TD =2.000

249
6.3.5 Seismic Analysis and Results
Given the above methodology, this cultural heritage structure was primarily analyzed to define
seismic parameters and their walls carrying capacity. Modal analysis was performed to
determine the basic vibration modes “and natural frequencies of the structure during free
vibrations. The purpose of this analysis is to obtain the maximum response of the structure in
each of its important ways, which are then summarized in a technically appropriate manner.
Modal analysis of the structure involves different modes of vibration” in a combined manner.

Figure 164. First mode of vibration from modal analysis (ETABS v.19)

Figure 165. Second mode of vibration from modal analysis (ETABS v.19)

250
Figure 166. Third mode of vibration from modal analysis (ETABS v.19)

Table 25. Modal periods and modal participating mass ratios (ETABS v.19)
Period
Case Mode UX UY SumUX SumUY RX RY SumRX SumRY
sec
Modal 1 0.489 0.7402 2.573E-05 0.7402 2.573E-05 7.622E-06 0.2231 7.622E-06 0.2231
Modal 2 0.452 0.0223 0.8224 0.7625 0.8224 0.2811 0.0063 0.2811 0.2294
Modal 3 0.45 0.1767 0.0978 0.9391 0.9202 0.0331 0.0486 0.3143 0.278
Modal 4 0.208 1.17E-06 0.0006 0.9391 0.9208 0.0004 6.814E-07 0.3146 0.278
Modal 5 0.186 3.312E-05 0 0.9392 0.9208 1.537E-06 0.0059 0.3146 0.2839
Modal 6 0.168 0.0493 7.554E-06 0.9885 0.9208 0.0001 0.5376 0.3147 0.8216
Modal 7 0.155 0.0002 0.0752 0.9887 0.996 0.6555 0.0022 0.9703 0.8238
Modal 8 0.151 0.0094 0.0007 0.9981 0.9966 0.0063 0.1523 0.9766 0.9761
Modal 9 0.115 0.0005 0.0001 0.9986 0.9967 0.0035 0.006 0.98 0.9821
Modal 10 0.115 0.0002 0.0003 0.9988 0.997 0.0106 0.0025 0.9907 0.9847
Modal 11 0.101 0.0005 4.316E-06 0.9993 0.997 1.125E-05 0.0069 0.9907 0.9915
Modal 12 0.094 6.002E-06 0.0011 0.9993 0.9981 0.0006 0.0001 0.9913 0.9916

Calculation methodology related to allowed period: [T]= 0.075 * Hb^0.75 (CEN Eurocode 8,
Eurocode 8: Design of structures for earthquake resistance -Part 1: General rules, seismic
actions and rules for buildings, 2008)

First mode: T1=0.489s ≈ [T] Translation move on X-direction, presence of torsion


Second mode: T2=0.452s Translation move on Y-direction, presence of torsion
Third mode: T3=0.450s Rotation move

251
6.3.5.1 Local results and diagrams

The following section will present diagrams related to the seismic response of perimeter
masonry and results related to the distribution of stress-strain in the most delicate parts of the
main facade of the building. The investigation of these parameters in the facade is the basis of
the methodology followed in this case study.

Figure 167. Stress S1-1 and S2-2 distribution on the main façade, according comb-1 (ETABS v.19)

252
Figure 168. Stress S1-1 and S2-2 distribution on the main façade, according comb-2 (ETABS v.19)

253
Figure 169. Story displacement diagrams, according to seismic comb-1 and comb-2 (ETABS v.19)

Figure 170. Story drifts diagrams, according to seismic E-x and E-y (ETABS v.19)

Comments the results of the local analysis of the facades masonry:


The maximum displacement values are observed in the global-x direction according to the
seismic combination 1, specifically in this direction the maximum displacement of the building
at the top reaches the value δ = 27mm. According to seismic combination 2, the building is
maximally displaced at the top in the global-y direction up to δ = 18.5mm. These displacements
are directly related to the geometric configuration of the building in the plan and the distribution
of masses against seismic actions, part of the combinations.

254
Figure 171. Story shear force local diagrams, according to seismic comb-1 and comb-2 (ETABS v.19)

Figure 172. Story overturning moment diagrams, according to seismic comb-1 and comb-2 (ETABS
v.19)

255
6.3.5.1 In-depth analysis in the framework of BIM modeling through “3muri software”,
analysis and investigations into possible masonry collapse scenarios

By the same logic as the first case study was treated, here too it was judged to perform non-
linear analyzes with 3Muri software v.13 academic version. In this case study, in the simulations
performed with etabs software only linear seismic analyzes were performed, where a series of
modal parameters were treated. Thus, through 3Muri software, in this paragraph an attempt is
made to investigate in more depth the mechanisms of masonry collapse.

Figure 173. Architectural model created in 3Muri software, axonometric view of the structure

Figure 174. Presentation of two axonometric front views of the model created in 3Muri software

The model in "3Muri software", presented in (figure 173) is created on the geometric data of the
current project, analyzing the materials of the architectural survey, recently performed in the
building. Regarding the limitations, it is emphasized that only half of the complex of buildings
256
has been modeled, specifically the main block near the "Mother Teresa" square, in the east
position of the building. The vertical block is also modeled, which connects this central block
with the western block of the concert hall, the interruption of the object is done exactly in the
position of connecting the blocks, near the seismic joint.

Figure 175. Numerical model according to the equivalence performed in 3Muri software, axonometric
view of the block at two different angles

Figure 176. Numerical model according to the equivalence performed in 3Muri software, view of the
main facade positioned in the east direction

257
Figure 177. Numerical model according to the equivalence performed in 3Muri software, (a) view of
the facade in the position of the connecting block, (b) view of the front facade

• Results generated after performing nonlinear analyzes simulated in 3Muri software

Figure 178. Summary table of capacity curves V-Δ, extracted in combination by 3Muri software for 24
analyzes performed in both seismic directions

258
700000
X - direction

600000

C.01 +X /Uniform L.
500000 C.02 +X /Static L.
Base Shear Force [daN]

C.03 -X /Uniform L.
C.04 -X /Static L.
400000
C.09 +X /Uniform L.
C.10 +X /Uniform L.
300000 C.11 +X /Static L.
C.12 +X /Static L.
C.13 -X /Uniform L.
200000
C.14 -X /Uniform L.
C.15 -X /Static L.

100000 C.16 -X /Static L.

0
0 0.5 1 1.5 2 2.5 3 3.5 4
Roof displacement [cm]
Figure 179. +X and -X direction combined capacity diagrams, processed from 3Muri numerical data

700000
Y - direction

600000

C.05 +Y /Uniform L.
500000
C.06 +Y /Statik L.
Base Shear Force [daN]

C.07 -Y /Uniform L.
C.08 -Y /Statik L.
400000
C.17 +Y /Uniform L.
C.18 +Y /Uniform L.

300000 C.19 +Y /Statik L.


C.20 +Y /Statik L.
C.21 -Y /Uniform L.

200000 C.22 -Y /Uniform L.


C.23 -Y /Statik L.
C.24 -Y /Statik L.
100000

0
0 1 2 3 4 5 6 7
Roof displacement [cm]
Figure 180. +Y and -Y direction combined capacity diagrams, processed from 3Muri numerical data

259
Table 26. Summary table of results obtained by 3Muri software, focused on nonlinear simulations of the
most problematic steps
No Seism Seismic α NC α SD α DL dm/dt Capacity curves
dir. load NC
1 +X Uniform 1.429 1.425 1.894 1.520 Capacity curve / analysis no.01 / +X direction

dt=1.52cm [NC], dm=2.31cm [NC], T*=0.38s


Analysis-01/Mechanism no.1 /Main façade masonry /seismic dir.+X/seismic load =uniform plot

Analysis-01/Mechanism no.2 /Internal hall masonry Analysis-01/Mechanism no.3 /Back façade, part of
/seismic dir.+X/seismic load =uniform plot south block /seismic dir.+X/seismic load =uniform plot

No Seism Seismic α NC α SD α DL dm/dt Capacity curves


dir. load NC
13 -X Uniform 1.296 1.282 1.804 1.468 Capacity curve / analysis no.13 / -X direction

260
dt=1.54cm [NC], dm=2.26cm [NC], T*=0.382s
Analysis-13/Mechanism no.1 /Main façade masonry /seismic dir.-X/seismic load =uniform plot

Analysis-13/Mechanism no.2 /Internal hall masonry Analysis-13/Mechanism no.3 /Back façade, part of
/seismic dir.-X/seismic load =uniform plot south block /seismic dir.-X/seismic load =uniform plot

No Seism Seismic α NC α SD α DL dm/dt Capacity curves


dir. load NC
19 +Y Static 1.022 1.042 1.363 1.123 Capacity curve / analysis no.19 / +Y direction
forces

dt=2.85cm [NC], dm=3.20cm [NC], T*=0.526s

261
Analysis-19/North side Analysis-19/ P-23 internal Analysis-19/ P-06 South façade of the intermediate block -
façade Mechanism /seismic panel Mechanism /seismic Mechanism /Internal/seismic dir.+Y
dir.+Y dir.+Y

No Seism Seismic α NC α SD α DL dm/dt Capacity curves


dir. load NC
23 -Y Static 1.358 1.273 1.499 1.357 Capacity curve / analysis no.23 / -Y direction
forces

dt=2.91cm [NC], dm=3.95cm [NC], T*=0.538s


Analysis-23/ P-02 North side Analysis-23/ P-18 internal Analysis-23/ P-04 perimetral panel Mechanism / North façade
façade Mechanism /seismic panel Mechanism /seismic of the intermediate block/seismic dir.+-Y/Static
dir.+-Y/Static dir.+-Y/Static

262
6.3.6 Conclusions and recommendations for the third case, regarding seismic simulations

The seismic and structural safety assessment of a heritage building has been carried out by
including in the study various “interrelated phases that include the basic knowledge of the
building and the investigation of its seismic performance. The application of this approach
methodology in the case of the University of Arts, located near Mother Teresa Square, showed
that the construction knowledge and technology phase is a fundamental step towards assessing
its structural behavior. An accurate critical-architectural-historical analysis, a detailed
investigation of previous geometric studies, characteristics of materials, basement data and a
meticulous construction of the cracking model allow to minimize the structural studies (and thus
intervention strategies) in the cultural heritage building”, thus preserving its necessarily history,
and cultural identity. Advancing further, “with an accurate assessment of the structural evolution
of the building over time, limits the costs for the investigation phase leading to a more accurate
seismic analysis of the structure”.

The model used for the analysis seems to effectively interpret the actual state and realistic
behavior of the structure in its current geometric and physical configuration. Through the
seismic analysis performed, a result is obtained, in terms of the progression of cracking patterns
and scenarios, a great resemblance appears to what is actually located in the structure. The
circumstances for which this result was obtained taking into account the state of dead loads of
the structure, and some of the impacts of recent seismic events.

Vibration periods for this object are considered within the allowable values, or very close to the
displacement threshold. First period T1 = 0489s ≈ [T1] = 0.511s. However, we cannot ignore
the fact that we have the presence of rotation in the first two modes. Rotation is found with small
values but also related to the large age of the structure are aspects that should be highlighted for
genuine retrofit strategies. These presence of rotational tendencies in the first vibrational modes
are also explained by the geometric shape of the building in the plan, which is a T-shape,
separated by a seismic joint in the middle. The presence of the joint does not affect the geometric
shape of the semi-T shape for the central block near Mother Teresa Square.

The behavior of more “complex structural parts, mainly perimeter masonry and slab panels, was
studied through a finite element analysis, the results of which (mainly static load transferred to
vertical elements through support reactions) were then applied to the simplified global model”.

6.3.6.1 Summaries and conclusions regarding the nonlinear simulations performed in


3Muri

Most of the damage that occurs during an earthquake is directly related to the existing condition
of the building, the parameters of the materials and the maintenance history over the years. It is
worth mentioning that the maintained structures, even without consolidation projects done,
perform much better than the structures weakened by lack of maintenance and degradation. The
resistance and performance of the structural system to resist future earthquakes can be
significantly reduced if previous interventions or seismic events have weakened the structure.
Also, if the parameters of the materials are deteriorated by humidity, termites, parasitic
vegetation or other accidental causes. In existing cultural heritage buildings, damaged mortar
joints between bricks can weaken entire building panels. From the site survey and investigations
263
made, such problems have been identified for this case, therefore, continuous maintenance,
which reduces to a maximum these problems, is essential.

It should be emphasized again that in order to have reliable results it is important to have many
models and simulations performed beyond the field work for the most unfavorable situations.
In this case we can conclude that the verified performance results in satisfactory levels, even if
we compare the results obtained from both software’s.

Various failure mechanisms and scenarios were predicted by 3Muri rating levels, summarized
above in Table 26. Thus, it should be emphasized that it is necessary to develop as many
theoretical and applied approaches as possible, in order to have a comprehensive result of the
possible seismic performance of the masonry panels. Summarizing from 24 pushover analyzes
performed, combined in both directions, only analysis no.19 + Ydir resulted in low parameters.
Which means that the vulnerability index αNC and αSD have values very close to the lower
limit, which provide clues for more in-depth investigations. Also in the analysis no.01 + Xdir
with "Mechanism no.1 positioned in Main facade masonry", or in the analysis no.13 + Xdir
where some local mechanisms with high probability of risk during a strong seismic event have
been observed. The local mechanisms investigated are of the "Shear failure" type in most cases,
followed by "bending damage and incipient bending failure", and in a few cases "bending
failure". From the investigation of the mechanisms in most of the steps performed, it is
evidenced that the most fragile part of the building is the central hall, specifically the joints at
the corners of the connection between two buildings. And in such cases to avoid this problem,
as an ideal recommendation would be the application of bracing systems, in two directions X
and Y, in the inner part of the structure, to give sufficient rigidity to the masonry panels, also to
increase global structure resistance.

To conclude, having a results report, which identifies areas of weakness, or elements with high
fragility, creates the possibility of using these results to assess the effectiveness of reinforcement
strategies and to contribute substantially to the design of appropriate reinforcement measures
that are essential in the case of cultural heritage structures.

264
CHAPTER 7.
Summaries and Conclusions

265
7.1 Summary of final Conclusions and Recommendations

The “multi-level approach followed in this study has shown its effectiveness in assessing the
vulnerability of the building designed by Bosio, noting the possible applications in a wide
variety of masonry cultural heritage buildings” of this period in Tirana, among others. Assessing
the structural and seismic safety of all these structures, requires appropriate knowledge,
extensive investigations, research in archives and documentation, browsing analog studies in
neighboring countries, intensive research phase, monitoring, investigation and extensive
interpretation of techniques in construction, both in terms of historical reconstruction of
buildings and previous restoration interventions, as well as the physical-mechanical
characteristics of the material.

The engineering approach does not advance further “to include possible structural rehabilitation
techniques that follow the principles of minimal intervention that should always be followed
when dealing with cultural heritage”. But this study leaves an open path for the selection of
materials and typology of retrofit interventions, which must be in accordance with the
architectural heritage of Tirana, in accordance with the principles of restoration and easily
movable or disassembled. This stage should usually be led by restorers, archaeologists,
historians, whose main interest is the preservation of the original architecture and structure of
the historic building. Recently in Albania, especially after the seismic events of 2019, “the
seismic safety of historic buildings has also seen the involvement of structural engineers, whose
main interest is to increase the seismic safety of the architectural heritage”. Engineers have been
involved in this process before, but without considering in their projects the architectural value
of the building where they intervene.

This professional practice, where there is fruitful cooperation between the architect-engineer
node, should be intensified and deepened, especially in the architectural wealth of cities, without
including monetary or political interests. Often, “architectural heritage is characterized by
construction techniques considered dated according to today’s standards and building codes.
The contrast between the needs for strengthening on the one hand and the preservation of
heritage on the other must become visible and tangible. Minimally invasive interventions are
recommended and preferred (e.g. introduction of new connecting rods, various injections” with
mortars containing fiber elements, local dismantling and reconstruction, replacement of old
mortar, intervention in facades until stability is not endangered ), in order to improve the
mechanical quality and performance of the walls, preventing the creation of mechanisms of their
collapse, based on all the theories addressed in the theoretical part of this study.

Finally, we can conclude the on-site study phase, survey process is a key aspect of this study.
Through the survey it has become possible to digitize the archival project of the building, while
at the same time it has become possible to build the current model of the building, which enables
us to perform a confrontation between the two periods. Confrontation in architectural but also
structural aspect. The field research process made possible the identification of the positive and
negative sides of the interventions in the masonry, aspects on the additions and how they affect
the performance of the building. The slab intervention in the concert hall has improved its local
performance. Meanwhile, special attention seems to be paid to the assessment of loads related
to the bearing capacity of continuous foundations. Through the field survey process, it was
initially aimed and later achieved, the awareness of architecture students to in-depth study and
culture of protection of cultural heritage objects, through their accurate restoration.
266
Along with the comments extracted and analyzed at the end of each chapter, a more concise
overview is summarized here. In terms of clarity, it is worth re-emphasizing the approved
research strategy:

• The first phase for each case study was “the analysis of structural typology”. Considered
as one of the most important features in the study of heritage buildings in Tirana, initially
addressed the historical and temporal evolution of massive masonry from the
architectural, constructive, construction technologies, designers and perspectives for
future plans. Recurrent damage after gravitational and seismic loads, the impact of
additions, structural interventions and functional adaptations over the years were also
investigated and analyzed.
• “On-site search and monitoring phase”. The difficulties presented by the review and
collection of archival projects, and the need to obtain real and current data on buildings,
made a good part of the study to take place on site. In this phase, several processes were
developed, such as architectural survey and digitalization of archival projects,
orthogonal photography with drones and processing of facades through the process of
photogrammetry, processing of data on facade problems, monitoring on the parameters
of masonry materials, etc. While at this stage it is worth mentioning the inclusion in the
process of architecture classes, within the curriculum of the Restoration of cultural
heritage, and the creation of a culture on the architectural value of the objects under
study, their preservation and maintenance.

• “Numerical analysis, F.E.M. models and engineering simulations”. Based on the results
of the previous step, aggregations of recent experimental results and a summary of
analogous study interpretations were discussed and compared with the numerical
analyzes of these three-dimensional models, part of this study.

• “Interpretation of results, and creation of a standard methodology” for the investigation


of structural problems, through a delicate process including the architectural sensitivity
of cultural heritage objects. Addressing the structural issue through a delicate process of
identifying the values of buildings and attempting long-term intervention strategies,
without affecting their aesthetics. Also treatments of engineering issues according to a
matrix of combinations with theoretical principles of restoration.

In order to define the objectives of the thesis as accurately as possible, an approach with
historical emphasis was treated, referring in particular to archival projects, design manuals of
that period, and the study of analogous projects in this field. This research tends to provide
valuable information for the structural analysis of facades, masonry and infills, from
architectural geometric aspects to the study of Italian technology and building codes in the past.
The results of this research are analyzed concisely in each case separately, which can represent
a valuable theoretical and practical support for researchers and engineers involved in the seismic
analysis of masonry for cultural heritage sites.

The on-site investigation phase and the survey process were essential to develop a valid
theoretical expertise for further studies on this masonry typology. To mention what was stated
267
at the beginning, the main purpose of this study was the simulation analysis and seismic
performance of Cultural heritage buildings. The objective can be considered fulfilled, but some
considerations need to be analyzed and elaborated. The main concern and limitation of this
research was the implementation of FEM analyzes for seismic simulation of masonry. However,
the finite element model showed expected results, and building responses, comparable to what
really happened. The comparison between numerical results and on-site facade damage
monitoring showed a significant correlation.

Regarding the numerical models used, great attention has been paid to the rigidity of the
masonry surface elements and layers, making an addition and equivalence of layers in the model
as loads. First, a simplified schematization of the masonry block model was proposed, ensuring
a considerable combination of layers. Second, the effect of surface layer stiffness was discussed
and tested in the first model, analyzing and investigating without significant differences in terms
of failure mechanisms and bearing capacity of these panels.

In more detail, several tentative strategies were attempted to model the masonry as the load /
mass accumulated and discretely between the bricks and mortar. From the point of view of
safety coefficients, the application on both sides of the spandrels of the equivalent load of the
horizontal layers of mortar turned out to be more conservative. Under the two boundary
conditions, the most influential parameters appeared, usually represented by tensile strength and
tangential stresses in the masonry panels. Also, the potential effects of damage on a larger or
global scale were analyzed and observed.

Summarizing some of the aspects addressed in this study, the problems found, the limitations
identified, the methodology used, analogous case studies, theoretical principles of restoration,
the recommendations of the Venice Charter and driven by the challenges that arise today, we
are aware that we are living in a period in which identities are characterized and become
increasingly distinct. Europe and the Balkans at the moment are characterized by cultural
diversity and consequently by the plurality of fundamental values in relation to dynamic,
immovable and intellectual heritage, by the various meanings associated with it and
consequently by conflicts of interest.

This requires all experts responsible for the preservation of cultural heritage to be increasingly
sensitive to the problems and choices they have to face in order to pursue the objectives set out.

Each community, through its collective memory, history and awareness of its past, is responsible
for identifying and managing its architectural heritage. This cannot be defined or solved in a
fixed way, with a formula. Only the way and methodology can be determined how the heritage
and its values can be identified, also the previous studies can be advanced and some of the gaps
can be filled. Creating matrices where it is attempted to provide ways for the most optimal and
efficient solution of these problems. Plurality in today's society also implies a great diversity of
the architectural and technical concept of cultural heritage as conceived by the entire expert
community and beyond. Architectural works, as the only tangible elements of heritage, are
carriers of values and wealth that can change perspective over time. This variability of values

268
that can be evidenced in architectural monuments is, from time to time, the complicated
specificity of heritage in different moments of the history of our cities.
Through this dynamic transition process, each country and community develops awareness and
campaigns for the need to protect the particular elements of buildings as identifiers of the values
of its common architectural heritage. The methods required very carefully to achieve a correct
protection must be adapted to different situations, in accordance with the basic principles of
restoration, undergoing a constant process of change and updating. The careful context of
selecting these values requires the preparation of a long-term conservation strategy and a set of
well-structured decisions. These should be algorithmically codified in a model restoration
project designed on the basis of appropriate architectural, technical and structural criteria.

• Maintenance, retrofit interventions and repairs are a key part of the architectural heritage
preservation process. These intervention operations or retrofit strategies should be
organized through systematic scientific research, on-site inspections, control,
monitoring and testing of material samples. Possible degradation of the material should
be predicted and described in detail, as well as subject to appropriate preventive
measures as appropriate.
• The conservation of the identified cultural heritage should be realized through the model
of a genuine restoration project, which includes strategies for its conservation in time.
This “restoration project should be based on a set of principles, choices and appropriate
technical solutions, also be prepared within a methodological process” that includes the
collection of sufficient information and an in-depth knowledge of the building,
parameters and technical data on materials, causes of problems and equivalent models
where multiple simulations have been performed on the performance of the object under
study. This process includes structural, seismic, thermal investigations, graphical and
dimensional analyzes and diagrams, as well as the identification of historical
significance or values, artistic and socio-cultural; The project requires the involvement
of all relevant disciplines mentioned above and to be coordinated by a group of qualified
persons with experience in related fields.
• Due to the vulnerability and special risk of our cultural heritage, any intervention related
to it should be strictly related to the context of the location, the principles of the
restoration charter, its territory and landscape. The destructive aspects of new
constructions by proximity to heritage, should be limited as much as possible.
Architectural artifacts and valuable elements must be fully documented and digitized for
each building. As in other cases, the intervention should follow the principle of minimal
intervention and should be performed by a group of experts with strictly controlled
techniques and methodologies.
• Re-establishment of an entire building, destroyed due to earthquakes or natural causes,
is allowed only in the presence of extraordinary social or cultural arguments, related to
the identity of an entire community.
• Re-construction of all parts and elements, "in style or by style" should be avoided as
much as possible. Interventions in limited parts which show architectural importance,
can be accepted provided that they are based on convincing arguments, accurate
documentation and indisputable reasons.
• Architectural decorations, frames and artistic artifacts strictly related to the built heritage
must be preserved and treated through a specific project parametrically related to the
general one. The restoration project must guarantee a correct approach to the

269
conservation of the entire structure, decorations and motifs, respecting the traditional
techniques of the designer, also their necessary integration as an essential part of the
built heritage.
• The strategy of interventions and seismic readjustment of buildings in the long run, is
closely related “to interdisciplinary research on materials, design codes and old
technologies used in the construction, repair and restoration of built heritage. Again
regarding the principles of restoration, the type of intervention selected must respect the
current function and ensure compliance with existing materials, static loads, structures
and architectural values. New materials to be used and new technologies must be
rigorously tested”, analyzed with computer models and numerous simulations performed
to predict any adverse situations, BIM modeling and applications, compare parameters
and adapt to real storage needs. When the in situ application of new techniques takes on
a special importance for the preservation of the original variant, it is necessary to ensure
a continuous monitoring of the results obtained, taking into account their timely conduct
and the possibility of possible restoration. The knowledge of materials, physical-
mechanical parameters, “traditional construction techniques and their archival
conservation in the context of modern society should be stimulated, being in itself an
important component of the cultural heritage of the country”.
• Regarding the recommendations and principles of the Venice Charter, the historic areas
of cities, in territorial terms, represent an essential part of the heritage related to the
objects under study and should be addressed in the ensemble of structures, spaces and
uses, allowing the process of evolution and stages constant change. This includes all
professionals, awareness and activation of the population, also requires an integrated
urban planning process, within which a wide variety of interventions are placed.
Interventions in buildings should always consider the reference of the city in its
morphological, functional, structural, and surrounding landscape.
• The diversity of values of architectural heritage and the diversity of today's interests
require a communication matrix that ensures the necessary and active participation of
residents in this process, specialists in the field and administration. It is imperative for
the community to create appropriate methods and structures to ensure the efficient and
effective participation of individuals and the attention of institutions in this decision-
making process.

Regarding the types of conclusions that were discussed above, an attempt has been made to
provide an applicable methodology for dealing with a delicate issue, an efficient method for the
careful handling of Tirana's heritage, and some recommendations which do not attempt to solve
all the problems, but to provide innovative ideas in improving the process of restoration and
conservation of architectural heritage.

The study tries to connect the Albanian context with the Italian cases to enrich the current
experience, to start a new phase in the treatment of architectural heritage, with a professional
spirit and without the influence of certain interests. The study through in-depth treatment of
archival projects has become part of the documentation and digitalization of cultural heritage
objects. Also the treatment done and the findings of this study are made fully available to other
researchers to advance with other aspects more applicable in relation to the strategies and
projects of restoration.

270
7.2 Comments and Recommendations on Modeling, findings from the interaction of data
files

During this study, numerous database models were created referring to 3 case studies. 3D
models and related files include geometric, graphic and numeric data. The main part of the study
is based on the connection of the architectural model with the structural one by making such
parameterizations to create the possibility of many simulations. The BIM and H-BIM models
were carefully studied, then the essence of their methodology was taken, to become theoretically
applicable to the Albanian case. However, the applicability of the methodology in a fixed way
for every possible case cannot be claimed. Cultural heritage cases are specific and require
detailed customized annexes or appendices to take into account a greater range of parameters.
Although in this study, in the applied part, many seismic simulations have been performed, and
are considered as a priority, in the context of the methodology they remain equivalent to other
links, such as architectural survey, digitalization, environmental simulations or time
transformation analysis of the building.

The database and numerical files of multiple 3d models cannot be effective if they are not
properly interconnected with each other or without creating simulation parameterization. In the
scheme of Figure.181 is shown as a set of files that supply data to the BIM model, and how the
BIM model provides and receives information continuously, aiming to create frequently updated
computer models, which are not only used for digitalization, digital archives or restoration
projects, but also perform the role of continuous monitoring of the performance of the building.

Figure 181. Interconnection of systems, explained in data file networks, referring to the second case

Based on this output scheme, it can be accepted that one of the limitations of the study is the
placement of sensors currently in buildings, although many computer simulations have been
271
done, but the part of their continuous investigation is missing. The recommendations are for
each building to have sensors in the framework of structural performance, mentioning masonry
monitoring, mechanical parameters of materials, displacements, distribution of stress-strain in
panels, etc. The second group of sensors that are recommended is in the environmental field,
such as monitoring the humidity on the surface or inside; mold, parasitic vegetation, shrinkage
of concrete or masonry, monitoring of masonry performance in frost periods; various
pathologies or masonry fractures due to weather; joint monitoring; etc. In this category of
recommendations care should be taken in creating a central system which collects data on the
server and distributes in numerical and graphical form the results required for analysis.

We can say that a new step beyond this study is the combination or parameterization of the
method, specifically models, with archival projects, researches and continuous data collected
from site-monitoring conducted by the institute of cultural monuments or institutional
government units, the creation of an “updated digital-archive in real time” for each object of
cultural heritage and their access by all professionals as stakeholders in the issue of restoration.

272
Figure 182. Summary diagram on the generated outputs for the 3 case studies, according to the
methodology proposed in this thesis

273
The database of 3D models presented in Figure.182, is the result generated according to the
applied methods BIM and F.E.M. In the analysis of this output product can be considered
something more than a point-cloud obtained from site drone photography, as it gives us the
opportunity to have comprehensive data and information about the geometry of the structure
and its behavior, materials and their parameters, as well as relate to satellite models for
simulations. So this 3d-model database, is the starting point for many structural simulations or
more, such as earthquake-related simulations, structural studies or analysis, environmental
simulations, energy simulations to the conservation, maintenance and intervention project of
restoration. In the summary diagram with the outputs shown in Figure.182 specifically for each
model analyzed according to the proposed methodology, specific evaluations are made:

• On the current state of structural performance, evaluating with three levels "poor,
medium, satisfactory";
• Seismic retrofit needs assessments evaluated with three levels "immediately, optionally,
no need";
• Assessments on continuous monitoring and maintenance of the building, including of
particular importance the monitoring of facades, including three level assessments
"immediately, optionally, no need";
• Assessments on the architectural adaptation of the building or reconfiguration in relation
to the needs of the institutions for expansion, including retrofitting, side additions or
temporary seasonal additions, interior architecture modifications such as wall removals
or wall additions, etc. With 3 levels of evaluation "is necessary, in progress, done".

From the findings of the simulations, the structural performance was evaluated as average
(starting from a conservative point of view). Beyond the concern of possible local damages,
mainly the buildings show satisfactory seismic performance, so regarding the need for seismic
retrofit for all three buildings, currently it’s not necessary, although detailed recommendations
and proposals are given for each possible case at risk. Frequent maintenance and monitoring of
all buildings has been evaluated with special importance and current needs. While for category
four we have different evaluations for the buildings, ascertaining during the investigation phase
that in the case of the Municipality building the adaptation has been done, mentioning the 1993
addition and the internal transformation, without forgetting the seismic performance analysis of
both blocks. In the case of the Polytechnic University building, an intervention in this context
is considered necessary. While for the 3rd case, the University of Arts is currently in progress a
partial intervention that consists in the transformation of the concert hall in the western block.
All these findings are formulated in the context of careful proposals to be considered in future
studies or by the design firm which will carry out the relevant interventions.

A good relational database, which tends to store as much data as possible about heritage
buildings is conceived and designed by connecting to the basic 3D model. The structure of the
methodology is designed to be quite flexible for handling the large amount of data that is entered
or intertwined towards the model, from multidisciplinary case studies. Choice to push the entire
model data network with a central "model-BIM" database, where they interact with each other,
information in the numerical and graphical database, or connection to satellite models. Referring
to this, the flexibility of the system within the methodology is ensured.

The flexibility of collecting and managing basic data is essential in this methodology when it
comes to handling cultural heritage buildings. The principle of methodology is sensitive to
274
specific case studies and in addition to data collection, does not provide standard intervention
solutions for each case. An attempt has been made to create an input-output system adaptable
to the specific treatment requirements of each case.

The theoretical-applied platform created in the framework of the improvement of the


methodology of the Restoration issue in Albania, based on theoretical studies, investigations
and analysis in relation to three selected case studies, establishes a theoretical basis on which it
is possible to continue the integration of other investigations. To create a complete and
functional digital archive based on multidisciplinary 3D modeling, historical context,
architectural surveys, typology, materials, architectural elements, structure and
multidisciplinary simulations.

The methodology developed and adapted for the Albanian case offers an experimental model
and an opportunity for improvement or reflection on the systematization of the required data,
for the proper management of restoration processes, improvement of structural performance and
adaptation of monument buildings to future plans.

The disclosed method highlights the possibilities for using BIM and fem models to address the
issue of restoration. The announced target is the creation of opportunities for effective use by
professionals, academic fields, as well as by government bodies or the institute of cultural
monuments for the protection of heritage buildings. This is essential and only in this way can it
be achieved to fully implement an application of this method in the Albanian context, achieving
the creation of an effective interdisciplinary relationship.

Normally, a number of boundaries or limitations are still present in this study mainly in terms
of the interconnection of modeling between software’s. While it must be acknowledged that a
satisfactory level of performance of the models has been achieved in relation to the data obtained
in the field during the architectural survey, or in relation to the archival projects, we can admit
that an acceptable level of data integration has been achieved, indicating great potential for
further developments for integration and high efficiency in the context of preservation,
monitored maintenance and adaptation of cultural heritage.

275
Bibliography

Halicioglu, F., Cakir, F., & Demirkesen, S. (2014). Structural assessment of traditional stone-
timber houses in Turkey. Gradevinar, 66(8), 727-738.
Abruzzese, D., & Miccoli, L. (2009). Diagnosis Techniques for Architectural Heritage via
Remote Control: Monitoring and Static Risk Assessment. Proceedings of 6th International
Conference on Remote Engineering and Virtual Instrumentation. Bridgeport: University of
Bridgeport.
Abruzzese, D., & Miccoli, L. (2009). Dynamic investigations on medieval masonry towers,
vibration measurement and structural identification. Protection of Historical Buildings,
Proceedings of PROHITECH 09. Rotterdam: Balkema.
Abruzzese, D., & Miccoli, L. (2009). Long life monitoring of historical monuments via Wireless
Sensors Network. Proceedings of 6th International Symposium on Wireless Communication
Systems, ISWCS 2009. Siena: University of Siena.
Abruzzese, D., & Miccoli, L. (2010). I nuovi materiali nell’ingegneria civile: i compositi FRP.
L'ingegnere, edilizia ambiente territorio, 52-56.
Abruzzese, D., Ferraioli, M., Lavino, A., & Avossa, A. (2020). Seismic Assessment, Repair and
Strengthening of a Medieval Masonry Tower in Southern Italy. International Journal of Civil
Engineering 18 (pp. 967–994). Berlin: Springer Science and Business Media LLC.
Abruzzese, D., Miccoli, L., & Vari, A. (2010). Permanent Monitoring of Historical Buildings
Structural Health via Remote Control. Proceedings of 8th International Masonry Conference,
8IMC. Dresden: Alinea Digitaldruck GmbH, Dresden.
Achille, C., Lombardini, N., & Tommasi, C. (2015). BIM & Cultural Heritage: compatibility
tests in an archaeological site. Building Information Modelling (BIM) in Design, Construction
and Operations, Witpress, 593-604.
Altea & geostudio. (2019). Technical report on laboratory tests of materials for cultural
heritage objects. Tirana: altea.
Amato, E. (2012). Case study 9. Software interoperability in the structural field with exportation
to IFC standard. In Osello A. The future of drawing with BIM for Engineers and Architects (pp.
159-163). Palermo: Dario Flaccovio Editore.
Angeli, K., & Pellican, M. (2000). L'intervento di restauro. Restaurator, 138-157.
Angulo Fornos, R. (2015). Digital models applied to the analysis, intervention and management
of architectural heritage. Building Information Modelling (BIM) in Design, Construction and
Operations, Witpress, 407-418.
Aplin, G. (2002). Heritage: Identification, Conservation, and Management. Oxford: Oxford
University Press.
Apollonio, F., Gaiani, M., & Sun, Z. (2012). BIM-based modeling and data enrichment of
classical architectural buildings. Scires-It, 2(2),, 41-62.
Asteris, P. (2003). Lateral stiffness of brick masonry infilled plane. J. Struct. Eng., 1071–1079.
Asteris, P. (2008). Finite element micro-modeling of infilled frames. J. Struct. Eng., 1-11.
Asteris, P., & Kakaletsis, D. (2011). Failure Modes of In-filled Frames. Electronic Journal of
Structural Engineering.
Asteris, P., & Sophianopoulos, D. (2011). Mathematical Macromodeling of Infilled Frames:
State of the Art. Journal of Structural Engineering.
ATC-40. (1996). Applied Technology Council, Seismic Evaluation and Retrofit of Concrete
Buildings. California.
Avrami, E., Mason, R., & De La Torre, M. (2000). Values and Heritage Conservation. Los
Angeles: The Getty Conservation Institute, The J. Paul Getty Trust.
276
Baballeku, M. (2014). Vleresimi i demtimeve strukturore ne ndertesat tip te sistemit arsimor,
Strukturat prej murature. Tirana: Universiteti Politeknik i Tiranes.
Balzani, M., & Dalla Negra, R. (2017). Architettura e preesistenze, Premio lnternazionale
Domus Restauro e Conservazione, Fassa Bartolo. Milano: Skira editore S.p.A.
Bazan, E., & Meli, R. (1980). Seismic analysis of structures with masonry walls. International
Association of Earthquake Engineering (pp. 633–640). Tokyo: IAEE.
Bianchi, G., Bruno, N., Dall’Asta, E., Forlani, G., Vernizzi, C., & Zerbi, A. (2016). Integrated
survey for architectural restoration: a methodological comparison of two case studies, The
International Archives of the Photogrammetry, Remote Sensing and Spatial Information
Sciences. XLI (B5), 175-182.
Bilgin, H., & Korini, O. (2012). Seismic capacity evaluation of unreinforced masonry residential
buildings in Albania. Nat. Hazards Earth Syst. Sci., 3753-3764.
Binda, L., Saisi, A., & Tiraboschi, A. (June 2000). Investigation Procedures for the Diagnosis
of Historic Masonries. Construction and Building Materials, 14(4), 199-233.
Brandi, C. (2005). Theory of Restoration. (©. Firenze : Nardini, Ed.) Roma: Roma : Istituto
centrale per il restauro ;.
Brandi, C. (2005). Theory of Restoration. (©. Firenze : Nardini, Ed.) Roma: Roma : Istituto
centrale per il restauro ; .
Brandi, C. (2015). Restoration, theory and practice. Palermo: F. Provenzani & C. Editore S.r.l.
Brooker, G., & Stone, S. (2004). Rereadings: Interior Architecture and the Design Principles
of Remodelling Existing Buildings. Newcastle: RIBA Enterprises.
Bufarini, S., D'Aria, V., & Giacchetti, R. (2009). Il controllo strutturale degli edifici in cemento
armato e muratura. EPC Libri.
Calvi, G. (1999). A displacement-based approach for vulnerability evaluation of classes of
buildings. J Earthquake Eng. 03, 411–438.
Campos-Costa, A., & Pinto, A. (1999). European seismic hazard scenarios—An approach to
the definition of input motions for testing and reliability assessment of civil engineering
structures, European Laboratory for Structural Assessment. Ispra, Italy: ELSA.
CEN Eurocode 8. (2003). Eurocode 8: Design of structures for earthquake resistance Part 3:
Strengthening and repair of buildings (prEN 1998-3:200X ed.). Brussels: European Committee
for Standardization.
CEN Eurocode 8. (2008). Eurocode 8: Design of structures for earthquake resistance -Part 1:
General rules, seismic actions and rules for buildings (FINAL DRAFT prEN 1998-1 ed.).
Brussels, Belgium: EUROPEAN COMMITTEE FOR STANDARDIZATION, TC250
Technical Committee.
Charleson, A., & Vesho, N. (2020). Structural engineering observations from the 26 November
2019 Mw 6.4 Albanian earthquake. NZSEE 2020 Annual Conference, 191-200. Retrieved from
http://www.nzsee.org.nz/
Code, E. m. (2005). Design of masonry structures, General rules for reinforced and
unreinforced masonry structures. Part.1 EN 1996-1.
Coisson, E., & Ottoni, F. (2015). Nuovi materiali per il restauro strutturale, una questione antica.
Arch history anno II, 92-117.
Crisafulli, F., & Carr, A. (2000). Analytical modelling of infilled frame structures - A general
review. Bull. New Zealand Soc. Earthquake Eng., 30-47.
Crisafulli, F., & Carr, A. (2007). roposed macro-model for the. Bull. New Zealand Soc. Earth-
quake Eng., 69–77.
Dalla Negra, R. (2020). Architectural Restoration and It's Various Interpretations. paesaggio
urbano 2.
277
D'Ayala, D., & Paganoni, S. (2011). Assessment and analysis of damage in L’Aquila historic
city centre after 6th April 2009. Bulletin of Earthquake Engineering, 2011, 81-104.
Dellapiana, E., & Bulegato, F. (2020). From architecture to design and back: the architectural
roots of the italian design system, 1920-1980. Res Mobilis. Oviedo University Press. ISSN:
2255-2057, Vol. 9, , 131-155.
Dhanasekar, M., & Page, A. (1986). Influence of brick masonry infill properties on the
behaviour of infilled frames. ICE Proc., 593-605.
Dhimgjini, V., Katundi, A., & Paci, E. (March, 2001). Reconstruction and extension of the
working histroy buildings of the Municipality of Tirana. Tirane.
Di Giulio, R. (2019). INCEPTION - Inclusive Cultural Heritage in Europe through 3D semantic
modelling. Retrieved from Inception s.r.l.: https://www.inceptionspinoff.com/en/inception-
spinoff/
Dicea Marche. (2014). Tradizione del restauro, tecnologie innovative per la conservazione, il
miglioramento, il consolidamento Strutturale. Ancona: Ahrcos.
Ermanno Tunesi, A. (2019, June). gio-ponti-prefabbricare-la-casa-allitaliana. Retrieved from
www.espazium.ch: https://www.espazium.ch/it/attualita/gio-ponti-prefabbricare-la-casa-
allitaliana
Eurocode 8, Part.1. (2004). Design of structures for earthquake resistance – Part 1: General
rules, seismic actions and rules for buildings. Brussels: Management Centre: rue de Stassart, 36
B.
FEMA 273. (1997). Federal Emergency Management Agency, recommended Provisions for
Seismic Regulations for New Buildings and Other Structures. Washington: ASCE.
FEMA 365. (2000). Federal Emergency Management Agency”, Pre-standard and commentary
for the seismic rehabilitation of buildings. Washington: ASCE.
FEMA 440, & NEHRP. (2005). Improvement Of Nonlinear Static Seismic Analysis Procedures.
Redwood: Department of Homeland Security, Federal Emergency Management Agency.
Fiorani, D., Fancelli, P., Modena, C., Da Porto, F., Valluzzi, M., & Dalla Negra, R. (2012).
Materiali e strutture, Problemi di conservazione. Roma: Dipartimento di Storia, Disegno e
Restauro dell'Architettttra .
Franceschi, S., & Germani, L. (2007). Manuale e Metodologie di intervento per il restauro e la
conservazione del patrimonio storico. Roma: DEI s.r.l.
Ghobarah. (2001). Performance Based Design in Earthquake Engineering. J. of Engineering
Structures, 878-884.
Idrizi, I. (2019). Influence of Brick Masonry Infill Walls on Seismic Response of RC Structures.
Technical Journal, University of Engineering and Technology (UET) Taxila, Pakistan, 862-869.
Idrizi, I., & Idrizi, Z. (2017). Infill Wall System for Seismic Protection of Residential Buildings.
Journal of Civil Engineering and Architecture 11, 862-869.
Idrizi, I., & Idrizi, Z. (2017). Numerical Modeling and Analysis of Unreinforced Masonry
Walls. Journal of Civil Engineering and Architecture 11, 870-878.
Jokilehto, J. (1998). The context of the Venice Charter (1964). Conservation and management
of archeological sites, 229-233.
Jokilehto, J. (2007). History of Architectural Conservation. London: Routledge.
Jurina, L., & Peano, A. (2009). Characterization of Brick Masonry Stiffness by Numerical
Modelling. Bergamo: Instituto Sperimentale modelli e Strutture s.p.a.
Kadluczka, A., & Cristinelli, G. (2015). Le carte del Restauro. Rome.
Kamran, Shakeel, A., & Rehan, A. (2016). Seismic Performance of a Heritage school building.
11th International Symposium on Plasticity and Impact Mechanics (pp. 1763-1770). Implast:
Elsevier.
278
Kerakoll. (2021). Linea edilizia / Ripristino e rinforzo c.a. e muratura. Retrieved from products
kerakoll: https://products.kerakoll.com/yep-
repository/kerakoll/media/GeoSteel_G1200_ITA_2021_I.pdf
Lorenco, P., Krakowiak, K., & Fernandes, F. (2007). Failure analysis of Monastery of
Jerónimos, Lisbon: How to learn from sophisticated numerical models. Eng. Fail. Anal. 280-
300.
Maffei, S., Pretelli, M., & Vassallo, E. (2005). Guida al corso di restauro architettonico.
Trieste: Edizioni Goliardiche.
Maietti, F., Di Giulio, R., & Balzani, M. (2018). 3D Data Acquisition and Modelling of Complex
Heritage Buildings. LECTURE NOTES IN COMPUTER SCIENCE, vol. 10605, 1-13.
Maietti, F., Di Giulio, R., & Piaia, E. (2018). Enhancing Heritage fruition through 3D semantic
modelling and digital tools: the INCEPTION project. MATERIALS SCIENCE AND
ENGINEERING, vol. 364, 1-8.
Mapei. (2019). www.albaedile.it. Retrieved from www.mapei.com/:
https://www.albaedile.it/wp-content/uploads/2016/05/mapegrid-G-220.pdf
Matero, F. (2007). Compensation, and Authenticity: The Contribution of Cesare Brandi to
Architectural Conservation in America. Philadelphia: PennDesign, Historic Preservation.
Menghini , A., Pashako, F., & Stigliano , M. (2012). Modern Italian architecture for the cities
of Albania. Bari: Collana Archinauti 36.
Menghini, A., Pashako, F., & Stigliano, M. (2012). Architettura Moderna Italiana per le citta
d'Albania, Modelli e interpretazioni (36 ed.). Bari: Collana Archinauti. doi:978-99943-0-269-7
Mitrojorgji, J. (2015). Building codes in Albania. City - forming process of traditional
settlements. Gjirokastra (Monuments, 53nd ed.). Tirana: Institute of Cultural Monuments
Albania.
Modena, C., Da Porto, F., Munari, M., Casarin, F., & Simonato, E. (2010). Cultural Heritage
Buildings and the Abruzzo Earthquake: Performance and Post-Earthquake Actions. Advanced
Materials Research Vols. 133-134 (pp. 3-17). Switzerland: Trans Tech Publications.
Morera, C. (2019). Cesare Brandi and contemporary art: theory, aesthetic and restoration. A
tempestuous dialectic. Conversaciones, 249 - 266.
Mosalam, K., Glascoe, L., & Bernier, J. (October 07, 2009). Mechanical Properties of
Unreinforced Brick Masonry, Section1. Lawrence Livermore National Lab. Journal, 03-26.
Nazarena, B. (2017). From survey to analysis for Cultural Heritage management: a new
proposal for database design in BIM. Parma.
Nieto-Julián, J., Lara, L., & Moyano, J. (2021). Implementation of a TeamWork-HBIM for the
Management and Sustainability of Architectural Heritage. Sustainability, 21-61.
Oddy, A., & Linstrum, D. (2005). Architectural Tiles: Conservation and Restoration, From the
Medieval Period to the Twentieth Century. Oxford: Copyright © 2005 Lesley Durbin. All rights
reserved.
Piaia, E., Di Giulio, R., & Rizal, S. (2017). Collective Self-Organised Housing: methods,
procedures and tools for new buildings and retrofit. TECHNE, vol. 14, 277-285.
Pitilakis, K., Crowley, H., & Kaynia, A. (2014). Typology Definition and Fragility Functions
for Physical Elements at Seismic Risk (ISBN 978-94-007-7871-9 ed.). New York, London:
Springer Science + Business Media Dordrecht. doi:ISBN 978-94-007-7871-9
Prifti, A. (2017). Ndikime te Arkitektures dhe te Artit Italian ne Shqiperine e viteve 1925-1943.
Tirane: academia.edu.
Rossetto, T., & Elnashai, A. (2005). A new analytical procedure for the derivation of
displacement-based vulnerability curves for populations of RC structures. Engineering
Structures, 397-409.
279
Schädler-Saub, U. (2008). Teoria e metodologia del restauro: Italian contributions to
conservation in theory and practice. In Conservation and Preservation: Interactions between
Theory and Practice: In Memoriam Alois Riegl (1858–1905). Polistampa, 1000–1014.
Sulstarova, Aliaj, Peci, & Muco. (2004). Catalogue of earthquakes in Albania with Ms=>4.5
for the period 8-2004. Tirana: Seismological Institute Tirana.
Tarque, N., & Leandro, C. (2015). Masonry infilled frame structures: state-of-the-art review of
numerical modelling. Earthquakes and Structures, 733-759.
Tomazevic, M. (1978). The computer program POR. Report ZRMK.
Tomazevic, M. (1999). Earthqauke-resitant design of masonry buildings, Series on Innovation
in Structures and Construction. In Innovation in Structures and Construction (Vol. I). London:
Imperial College Press.
Tomazevic, M. (2007). Damage as a Measure for Earthquake Resistant Design of Masonry
Structures, Slovenian Experience. Journal of Civil Engineering (Canada), 122, 1040-1047.
Tomazevic, M. (2007). Damage as a Measure for Earthquake Resistant Design of Masonry
Structures: Slovenian Experience. 122, 1040-1047.
Turnsek, V., & Sheppard, P. (1980). The shear and flexural resistance of masonry walls. the
Intern. Research Conference on Earthquake Engineering, (pp. 517-573). Skopje.
Valluzzi, M. (2012). Round Robin test for composite to brick shear bond characterization.
RILEM, Materials and Structures. doi:10.1617/s11527-012-9883-5
Vesho, N., Guri, M., & Marku, A. (2019). Ferrocement composites for strengthening of existing
school structures in Albania, ISSN: 2319-9873. Journal of Engineering and Technology, India.
(dsvsv). vssVd.
Weerbeck, M. (2019). Brandi and the restoration of contemporary art. One side and the other
the Teoria. Coversaciones, 211-226.
Wilson, E. (2002). Three-Dimensional Static and Dynamic Analysis of Structures, A Physical
Approach With Emphasis on Earthquake Engineering, Third edition. USA: Computers and
Structures Inc.
Xu, H., Gentilini, C., Ju, Z., Wu, H., & Zhao, S. (2018, September 30). A unified model for the
seismic analysis of brick masonry structures. Construction and Building Materials, Elsevier Ltd.
vol.184, pp. 733-751.
Yazdani Mehr, S. (2019). Analysis of 19th and 20th Century Conservation Key Theories in
Relation to Contemporary Adaptive Reuse of Heritage Buildings. mdpi journal heritage, 920-
937.

280
8. APPENDIXES

281
8.1 APPENDIX A. “The former building of National Theatre”. Numerical analysis and
investigations, before and after demolition - CASE IV

8.1.1 The historical and architectural context of the case

Ex “Italo-Albanian circle, Skanderbeg”, the national theatre building was built in 1938 by the
Milanese design company Pater, special constructions immediately behind the Ministry of
Public Works. At the time of design it was a multifunctional building (with presence of a
swimming pool, sports fields, restaurant, theater and some halls) organized into three buildings
blocks linked organically by a porch. Regarding the Italian style of architecture of the time, “the
volumetric composition was strongly symmetrical, also highlighted on the I by two tower heads
corresponding to the two longitudinal buildings, the internal space of the courtyard was
contained between two porticoes, one longitudinal between the I towers and the other circular
exedra on the back. The facades of the two longitudinal arms, symmetrical, recalled a post-
futuristic language halfway between Sant’Elia and a painting by De Chirico”. From the
constructive point of view, it was an experimental building built with the patents of Pater Studio
in a mixed structure of cement walls combined with populit panels and wood truss structure in
the roof.

Figure 183. National theatre location and positioning with the central square (Menghini , Pashako, &
Stigliano , Modern Italian architecture for the cities of Albania, 2012)

Over the years, through a difficult transition phase the building has undergone various
tampering’s with respect to its first configuration, as early as 1943 the Town Plan envisaged the
demolition and reconstruction of the porticoes on both sides (not carried out); between 1945-
1947 there was a modification of the rear porch and the architectural re-functionalization of the
national theater, subsequently changes were made to the covers of the service spaces for the
theater and offices; in 1954 the rear side of the courtyard was closed with a rectangular building
used as a carpentry shop. Until 2020 the building houses the National Theater, externally
restored, its interior is in many parts dilapidated. The new Master Plan of the center of Tirana
in 2002 foresees its demolition. Unfortunately, in the spring of 2020, the building was
demolished by the municipality of Tirana by a government legal order, regarding its degraded
condition and its non-functionality regarding the requirements of the institution.

282
Figure 184. National theatre ground floor plan, main façade view and technical details of the structural
project (Menghini , Pashako, & Stigliano , Modern Italian architecture for the cities of Albania, 2012)

Figure 185. National theatre structural details and “populit panels” used on structural masonry (Ermanno
Tunesi, 2019)

283
The wall openings are made between the concrete columns and consequently always have the
same light-length. A collaborative role played by the wooden boards of the 3x15 cm section
which reinforce the vertical structure and are disposable formwork for the pillars. The casting
of concrete for the realization of the supporting pillars therefore took place between the wooden
planks and the “populit slabs”, used as infill, as it appears from the traces still visible today.

This material, produced by “S.A.F.F.A. (Società Anonima Finanziaria Fiammiferi e Affini)”


was an agglomeration of vegetable substances (poplar chipboard fiber, waste product from the
factory of matches and seaweed) mixed with high-strength cement that allowed the creation of
a resistant product, with good thermal and acoustic insulation. “Today many of the original
functions of the club have disappeared and the complex houses” only a theater and its service
spaces. The portico, consisting of cylindrical concrete pillars, which connected the various
buildings to the demolished state and the entire complex has undergone many changes over the
years: in fact, extensions and superfetation’s that have changed the volumes and the shape of
the courtyard are recognizable. At the planning stage, the refurbishment of the complex was
hypothesized: the right wing was destined for the City Museum of Tirana while the left wing
chose to preserve the theater by annexing spaces to be used for classrooms, laboratories, services
and exhibition spaces.

It “was also chosen to demolish all the extensions and superfetation’s made over the years,
safeguarding the original parts of the complex and creating a transversal volume between the
two longitudinal bodies, a sort of fifth, with the function of connecting the various levels,
accessible through a monumental staircase, below which there is a conference room.”

The “expansion was achieved through the iteration of wooden portals grafted onto a stone base
and a continuous casing also made of wood. The full-height museum space, below which a large
underground room develops, is divided into long galleries by means of a series of wall boxes
containing niches and small exhibition areas.”

The elevations of the museum extension, made up of movable panels to regulate, together with
those of the roof, the entrance of the light, have large engraved or raised writings of “futuristic
ancestry, as if they were” “graphic pages”, “thus creating that fusion of architecture and visual
arts typical of the years in which the building was born.”

The “ephemeral nature that had characterized the construction of the building is declined in light
of new construction needs and technologies, accepting its appearance as a temporary pavilion
and reinterpreting it as a large” “exhibition machine”.

284
Figure 186. National theatre project details and building evaluation (Menghini, Pashako, & Stigliano,
Architettura Moderna Italiana per le citta d'Albania, Modelli e interpretazioni, 2012)

This case study is focused on the context of Tirana’s cultural heritage buildings, designed during
the 1938-1939s. “Tirana represents a special scientific occasion, unique in terms of researching
Italian design mixed with Albanian layers over the years. This feature has resulted from many
political, economic and social factors of the time that fundamentally changed the way of vision
and architectural conception in our capital.”
Every cultural heritage is inseparable from history as a witness of which it is, as well as from
the place where it is located. Consequently, complete or partial interventions in a cultural
heritage may not be permitted, except cases when the preservation of the heritage requires, or
when this is justified by reasons of great national or international interest.
This study aims to analyze the restoration of these buildings, by means of seismic retrofit ways,
preserving aesthetic and historical values. The main goal is to turn these buildings into full use
of their previous function, increase their lifespan or value identification in our case.
The focus of this study is the identification of structural problems in these buildings, secondly
3d modeling, simulations, scenario-investigation and in-depth structural analysis.

285
In this work the peculiarities of the global response of old building are shown with the aid of a
simplified physical 3d model, realized with SAP2000 software, able to reproduce earthquake
damage to composite-masonry buildings and failure modes observed in experimental tests. The
application of this methodology to Albanian composite-masonry typologies points out the
difficulties related to existing buildings.

8.1.2 Theoretical interpretations of the case and methodology used

The historical and architectural heritage of Tirana is located along the main axis and the main
boulevard of the city. A valuable part of this architectural heritage over time is losing the
attention of citizens and the government, demolishing to build high towers. One of these heritage
objects of Tirana is complex of the National theater buildings, which was just demolished by
the government this june. The national theatre represents features of Italian architecture
integrated with Albanian motives during the years. Italian architecture changed the image and
history of Tirana, giving it a modern-style referring to the time was a building full of elegance
and architectural harmony. Over the years this building changed its function several times. Also,
small non-structural interventions have been made several times. (Menghini, Pashako, &
Stigliano, Architettura Moderna Italiana per le citta d'Albania, Modelli e interpretazioni, 2012)
The relationship that the Italian architect built from time to time with the new geographic and
cultural context was certainly a guide to his preparation and sensitivity. (Prifti, 2017)
The structural typology of the building of arch. F. Di Fausto, A. Brasini and G. Bosio consists
of building types with retaining walls combined with columns in some cases. The thickness of
the walls varies and is reduced by the height of the building, the foundations are of stone and
can be considered continuous beams, between the floors there are thin concrete beams and the
slabs types works as shells [37]. The facades of these buildings are carefully crafted with
decorative details of traditional Albanian motives, accompanied by the charm of the Italian
architecture. The preservation of historical buildings from damage due to earthquakes, also the
need to make their structures stable and safe, especially for their historical value, became
essential, also to restore forgiveness and attention to them.
Due “to reasons such as age of building, interventions made by people, interventions by
modifying the interior facilities of the buildings, or adding new parts, the old codes design
methodology [38] of the time, these types of buildings are vulnerable to earthquakes (Mitrojorgji,
2015). It is therefore important to evaluate the seismic performance and the life of these
buildings. So, based on this assessment, techniques must be developed to strengthen these
buildings in order for them to resist potential earthquake damages and other challenges in the
future.” The buildings that will be part of this study doesn’t have RC-columns and beams. Their
main structure is based on the brick masonry URM typology. “Therefore, they are more
vulnerable to seismic action” [39]

37
Shell-type behavior: both in-plane membrane stiffness and out-of-plane plate bending stiffness are provided for
the section. The Shell type will combine the rigidities from both Membrane and Plate.
38
Albanian technical code and Italian design code (1920-1940)
39
Shaking and seismic frequency activity.
286
As a traditional building, this typology can be found almost in all the central part of Tirana.
Consequently, “it may be subjected to different climatic conditions and may have suffered
various degradations”.
A common or a frequent approach is to treat all cultural heritage assets similarly, which results
in a skewed list of priorities. On the other hand, it should be recognized that seismic risk varies
from building to building or cultural heritage asset to cultural heritage asset. The widespread
assumption that risk is low is frequently caused by erroneous observations: If a monument was
built several hundred years ago and has remained relatively unscathed in recent years, this does
not mean that the risk is low. There is evidence that a significant number of really ancient
monuments collapsed during the recent quakes.
This perfectly acceptable sentence demonstrates the critical nature of correct architectural
design and ongoing maintenance. While testing from previous earthquakes is well documented,
structural safety can be attained only with the assurance of good design, continual maintenance,
and testing.
Finally, degradation of construction materials and damage caused by recent earthquakes are a
concern, particularly when these were not restored adequately or at all. These factors may result
in considerable losses in the seismic capacity of the building. Consideration should always be
given to damage accumulation. The idea that old construction is synonymous with good
construction is once again called into question by the inexorable march of time. With our case
study shown below we estimate and evaluate the selected building to the action of seismic elastic
spectrum [40] according the Euro code 8. According the methodology, it is used the static linear
analysis [41] and the masonry of the building is modeled with nonlinear behavior [42].

8.1.3 Explanations and interpretations on the structural model used

The seismic risk class depends on one parameter: which takes into account the “damage and
refers to the cost of reconstruction of the building; taking into account the achievement of the
limit state to ensure the safeguarding life” of people inside the building, during an Earthquake
(life safety level)[43]. The use of F.E.M. model[44] interpretation of the crack Pattern and their
distribution.

The assessment of seismic performance of U.R.M. buildings[45] requires the identification of the
collapse mechanisms and masonry local damages step by step activated by the synthetic
earthquake (elastic demand spectrum) [46]. Referring the current practice in our region has been

40
Elastic spectrum represents a series of synthetic equivalent earthquakes summarized in one.
41
A linear static analysis is an analysis where a linear relation holds between applied forces and displacements. In
practice, this is applicable to structural problems where stresses remain in the linear elastic range of the used
material.
42
Methodology for modelling the unreinforced masonry with nonlinearity characteristics for each layer of the wall
on ETABS, a possibility to create the wall as close as possible to reality.
43
Second level mostly used for designing civil structures based on seismic performance levels [Eurocode 8]
44
The finite element method (FEM), is a numerical method for solving problems of engineering and mathematical
physics
Unreinforced masonry building typology, without reinforced concrete frames.
45

Merging a number of strong short-period ground motions and long-period ground motions. From the
46

merging of these accelerograms, an elastic specter is deduced.


287
taken into account only three first modes of failure, by studying the capacity curves of certain
structural typologies, to get the right strategy for strengthening and updating the structure.
The modelling of the structure behavior and its safety assessment by mesh process (finite-
elements) can highly benefit of the ETABS, which enables us to create layered walls,
considering the non-linearity of each layer that represent materials data. (Vesho, Guri, & Marku,
2019)
The most important step is transformation and conversion of panels in piers and spandrels
labeling [47]. The vertical panels working in compression are converted in the Piers (frame
elements that work in compression), while the horizontal panels under the openings below are
converted to the spandrels (beams in bending) (Pitilakis, Crowley, & Kaynia, 2014). The
methodology for the analytical part was performed on modal analysis (CEN Eurocode 8,
Eurocode 8: Design of structures for earthquake resistance Part 3: Strengthening and repair of
buildings, 2003).
Investigation procedures: In general the necessity of monitoring and investigating the “building
integrity or the load carrying capacity of a unreinforced masonry building arises for several
reasons including: assessment of the safety and stability of the structure before or after a seismic
event, extension of the building and also the change of use, assessment of the effectiveness of
repair innovative techniques applied to structures or different materials, and long-term
monitoring of material parameters and structural performance.” (Binda, Saisi, & Tiraboschi,
June 2000)

8.1.4 Modal analysis “Structural evaluation and seismic performance of the National
Theater, Tirana”

Below is presented the object to be analyzed, the National Theater building after interventions.
The “constructive-structural project with drawings and technical specifications for this building
are taken from the technical archives” of Tirana, to be analyzed and investigated later.

47
pier = column, spandrel = beam. Both piers and spandrels are equivalent panels constructed of shell
elements, showing the element way of work according the static concept.
288
Figure 187. The National Theater finite elements structural model analyzed (SAP2000 V.22)

The typology of the existing building is a composite-masonry structure which consist of a


mixture between wood and concrete with 2 different masonry thicknesses, 23cm at basement
level and 20cm. The last thickness is mainly used as a separating wall between rooms and on
the upper levels. (Menghini, Pashako, & Stigliano, Architettura Moderna Italiana per le citta
d'Albania, Modelli e interpretazioni, 2012)

This kind of masonry structures have low masses and they respond well to seismic waves, but
due to the interventions that have been occurred the masses have changed.
The building has been modeled in SAP2000 v22 and due to the lack of the program for masonry
type of buildings the masonry has been modeled as a reinforced concrete wall with a decreased
capacity.
Mechanical properties of masonry:
• Material property data Masonry
• Directional symmetry type: Isotropic
• Weight per unit volume: 8 kN/m3
• Mass per unit volume: 256 kg/m3
Material mechanical property data:
• Modulus of elasticity: E=18608 MPa
• Shear Modulus: G=7753 MPa
• Poisson’s ratio: u=0.2
• Coefficient of thermal expansion: A=10-5 l/C

The masonry behavior is modeled as a linear shell-thin with a low compressive strength
concrete. The importance is to see where the combination of the vertical stresses S1-1 and the
horizontal stresses S2-2 would intersect and create additional stresses.
289
8.1.5 Seismic parameters

Eurocode 8 have a detailed specific “way to calculate the seismic spectrum. In this case it
depends on several factors: peak ground acceleration p.g.a, the category of the soil, the predicted
magnitude (in the case of Albania is used M > 5.5) and the behavioral factor. This last one as a
concept is comparable to the inverse of ductility. Given the studies, Albania has a variety of
seismic peak ground acceleration from 0.15-0.31g. (CEN Eurocode 8, 2008) With the same
reasoning as above, we choose the seismic acceleration that has greater surface in the seismic
map. Eventually the selected parameters are:”

- Soil category: C
- Spectral acceleration: ag/g = 0.27m/s2
- Direction: Horizontal
- Behavioral factor: Damping factor: 5%

Figure 188. Elastic demand spectrum, referring Tirana ground


parameters (SAP200 V22)

8.1.6 Seismic analysis and results obtained

Given the above explanation in methodology, historical heritage was primarily analyzed to
define seismic parameters and their walls load carrying capacity.

Modal analysis was used also in this case to establish the structure's fundamental seismic
“modal-shapes” and “natural frequencies” parameters of self-vibration during the earthquake.
The goal of modal analysis is to determine the structure's maximum response in each of its
significant modes, which are then summed appropriately. The structure was subjected to a modal
analysis using a mixture of several modes of vibration in accordance with Eurocode
methodology.
290
Figure 189. First 3 modes of vibration according to SAP2000 V22 for the case study

Figure 190. Modal data, frequencies and seismic parameters, obtained from the technical report
generated in the software (SAP2000 V22)

Modal parameters reffering the allowed period formula: [T]= 0.075 * Hb^ 0.75 (CEN Eurocode 8,
Eurocode 8: Design of structures for earthquake resistance -Part 1: General rules, seismic
actions and rules for buildings, 2008)

First mode: T1=0.49 s > [T] Translation move on X-direction


First mode: T2=0.367 s Translation move on Y-direction and presence of torsion
Third mode: T3=0.348 s Torsion

The problematic part that needs to be studied critically is in the Y direction due to the fact that
the structure is more flexible in that direction and it shows problematic displacement in the
middle of the building. This phenomenon is problematic because it causes additional flex and
in masonry buildings normally this causes serious problems.

To get more detailed information for the vertical and horizontal stresses the south part of the
building has been mashed 50cm by 50cm.

On the south side there are 3 surfaces and each surface has been studied individually as follows:

291
Figure 191. Main stresses distributed on the surfaces taken in the study (SAP2000 V22)

Figure 192. Distribution of stresses in the longitudinal I of the building, according to the two components
σx and σy (SAP2000 V22)

The minimal stress amount occurs on the lower end of the building and the maximum on the
upper part, the part where the roof lay. Beside the uniform stresses there is one concentrated
stress on the upper left corner of the second surface. The maximal uniform stresses are between
1.2-1.6 N/mm2 and the maximal concentrated stress is 4.2 N/mm2 which is a way higher value
than the 1.1 N/mm2 which is the maximal stress allowed on masonry buildings. (CEN Eurocode
8, Eurocode 8: Design of structures for earthquake resistance -Part 1: General rules, seismic
actions and rules for buildings, 2008) This kind of stress has been removed on the other corner
due to the seismic gap that has been applied on the model.

8.1.7 Summarized conclusions and recommendations

This study focuses on historical heritage masonry structures situated in Tirana, “located in a
seismically active zone. The objective was to analyze damage mechanisms and seismic
vulnerability of the selected building. First a brief description of structural features and
architectural characteristics of Italian typology was presented. This is followed by modelling
one of the most typical building of this period to visualize structural response behind seismic
events. A F.E.M 3D model was prepared in order to show behavior of the structure and its
probable local and global weaknesses under seismic actions”. The modal analysis is applied to
292
predict the most “possible damages and seismic vulnerability in weak zones of the structure
under expected seismic intensity”.

The static and modal analysis results have revealed that the critical section for the selected
building is the transition zone between the section changes on the X direction and this is due to
the lack of the seismic gap because the building length overpasses the 100m and there should
be two seismic gaps on the geometric-section changes. This kind of stresses creates structural
stability problems and it might be considered as one of the firs interventions that should have
been done to the building.

The addition of the new interventions and the new additions might have increased the weight of
the building and the period might have changed, making it even higher and more problematic.

293
8.2 APPENDIX B “Technical engineering and architectural diagrams” – CASE I

Figure 193. Architectural survey, in the framework of data processing related to the BIM model

294
Figure 194. Diagram related to the analysis of urban planning of the area between periods

295
Materials summarized from simulations on investigations of possible collapse scenarios,
selected from areas which have exhibited significant fragility in seismic performance. Simulated
models according to the local theoretical mechanisms of collapse (worked in 3Muri software):

Figure 195. Simulations of local failure mechanisms, analyzed position "northern side facade"

296
Figure 196. Simulations of local failure mechanisms, northern side façade. 3D view in the context of
possible collapse scenarios

297
Figure 197. Simulations of local failure mechanisms main western facade, combined diagrams in the
framework of possible collapse scenarios

Figure 198. Simulations of local failure mechanisms north side facade, second typology of possible
collapse scenarios

298
8.3 APPENDIX C “Technical engineering and architectural diagrams” – CASE II

Figure 199. Architectural survey, main facades reworked for digitalization process (Credits R. Qose, A. Abdullaj)
299
Figure 200. Architectural survey, pieces from the BIM model & details reworked on Rhino v.07, part 1
(Credits: R. Qose, A. Abdullaj)

300
Figure 201. Architectural survey, 3D model & details reworked on Rhino v.07, part 2 (Credits: R. Qose,
A. Abdullaj)

301
Figure 202. Architectural survey of windows, doors and arches

Figure 203. Careful sketching in detail stone by stone, mortar joints, façade elements and details

302
Figure 204. Analysis and investigation of the current condition of facades, pathologies and degradation;
left survey of architectural elements

303
Figure 205. Architectural survey of the facade in the framework of the investigation of pathologies,
cracks distribution and fractures

Figure 206. Collage of photos showing the current state and degradation of the material into different
elements

Figure 207. Processed diagram, based on laboratory data, showing the mold content in the main facade
tiles

304
Figure 208. Material degradation analysis and photogrammetric processing of facades, in the framework
of Bim modeling (credits S. Agalliu, B. Ndoja)

305
Figure 209. Column C12H14, C18H13 nad C7H13 hinge response diagrams, according to push-Y load

Figure 210. Column C25H15, C24H16 nad C28H15 hinge response diagrams, according to push-Y load

306
Summary of materials from local simulations, in the framework of the investigation of possible
collapse scenarios, carried out in areas with significant structural fragility. Analysis performed
according to the local theoretical mechanisms of the collapse (worked in 3Muri software):

Figure 211. The first simulation in the framework of the investigation of local mechanisms of perimeter
side panels, the scenario of possible mechanisms

Figure 212. The second simulation in the framework of the investigation of local masonry mechanisms
related to the ground floor masonry, the scenario of possible local mechanisms

307
8.4 APPENDIX D “Technical engineering and architectural diagrams” – CASE III

308
Figure 213. Analysis on the urban planning of the area between 2 periods, project identification

309
Figure 214. Architectural survey process, sketches of interior elements "windows" and constituent
elements

310
Figure 215. Architectural survey process, sketches of interior elements "doors" and constituent
elements

311
Figure 216. Analysis of the main facade against fractures in marble and moisture content

312
Figure 217. Analyzes on the condition of the masonry, the distribution of mold, parasitic vegetation and
blackening of marble

313
Even in this case, materials were collected from local simulations to investigate possible
collapse scenarios, only for areas with significant fragility. (3Muri software):

Figure 218. Simulations in the framework of the local mechanisms investigations, mechanism one

Figure 219. Simulations in the framework of the local mechanisms investigations, mechanism two

314
Questa pagina è stata lasciata intenzionalmente vuota