TERMODINAMIKA

DASAR A
MODUL I
TK 3081-Termodika Dasar A
UTS 2009

1. An ideal gas, Cp = 3,5 R is heated in a steady state heat exchanger from 70oC to 190oC
by another stream of the same ideal gas which enters at 320oC. The mass flow rate of
the two gases are the same and heat losses from the heat exchanger are negligible. (a)
Calculate the molar entropy changes at the hot and cold stream for both co-current and
counter-current flow in the exchanger! (b) What is ΔStotal in each case? (c) Repeat part
(a) and (b) for counter current flow if the heating streams enters at 200oC!
2. Consider two reversible heat engines where the heat flow is arranged in series. The first
engine A has heat addition at 400oC and heat rejection at temperature T. The second
heat engine B receives at temperature T the heat rejected by first engine, and in turn
has heat rejection at 5oC. Calculate the temperature T, in degrees Celsius, for the
situation where (a) the work outputs of the two engines are equal and (b) the thermal
efficiency if the two engines are equal!
3. Consider steam generation in a boiler using flue gas (gas from combustion) at heat
source. Liquid water enters the boiler at 100oC and leaves at 100oC as saturated steam
x = 100%. Due to heat release for the steam production, the temperature of the flue gas
decreases from 1110oC to 150oC. The flue gas heat capacity is given by: Cp/R = 3,83
+ 0,000551 T (K), latent heat of vaporization of water = 2257 kJ/kg. (a) With references
to a surrounding temperature of 25oC, what is the lost work of this process in kJ/mol of
flue gas? (b) With references to surrounding temperature of 25oC, what is the maximum
work in kJ/mol of flue gas that can be accomplished by the saturated steam at 100oC if
it condenses only (does not cool)?
SOLUSI
TK 3081-Termodika Dasar A
UTS 2009

1.An ideal gas, Cp = 3,5 R is heated in a steady state heat exchanger from 70oC to 190oC
by another stream of the same ideal gas which enters at 320oC. The mass flow rate of the
two gases are the same and heat losses from the heat exchanger are negligible. (a)
Calculate the molar entropy changes at the hot and cold stream for both co-current and
counter-current flow in the exchanger! (b) What is ΔStotal in each case? (c) Repeat part
(a) and (b) for counter current flow if the heating streams enters at 200oC!
Solution:
Heat Exchanger Energy Balance:
𝑚̇𝑐𝑜𝑙𝑑 𝐶𝑝 ∆𝑇𝑐𝑜𝑙𝑑 = 𝑚̇ℎ𝑜𝑡 𝐶𝑝 ∆𝑇ℎ𝑜𝑡
∆𝑇𝑐𝑜𝑙𝑑 = ∆𝑇ℎ𝑜𝑡
𝑇2𝑐𝑜𝑙𝑑 − 𝑇1𝑐𝑜𝑙𝑑 = 𝑇1𝐻𝑜𝑡 − 𝑇2 𝐻𝑜𝑡
𝑇2 𝐻𝑜𝑡 = 320 − 190 + 70 = 200𝑜 𝐶

Th1 320oC
320oC Th1

200oC Th2
Th2 200oC
190oC 190oC Tc2

Tc1 70oC Tc1 70oC

Co-Current
Counter-Current
𝑇2 𝐶𝑝 𝑑𝑇 𝑃2
Recall Entropy Change:∆𝑆 = ∫𝑇1 𝑇 − 𝑅 ln 𝑃
1
𝑇2
Case: Constant Cp and Constant P  ∆𝑆 = 𝐶𝑃 ln 𝑇1
(a) ΔS for counter currents is the same for co-current since the initial and final
temperature are the same for both cold and hot stream.
𝑇 190+273 𝐽
∆𝑆𝑐𝑜𝑙𝑑 = 𝐶𝑃 ln 𝑇2𝑐𝑜𝑙𝑑 = 3,5 𝑥 8,314 𝑥 ln ( 70+273 ) = 8,730 𝑚𝑜𝑙.𝐾
1𝑐𝑜𝑙𝑑
𝑇2ℎ𝑜𝑡 200+273 𝐽
(∆𝑆ℎ𝑜𝑡 = 𝐶𝑃 ln 𝑇 = 3,5 𝑥 8,314 𝑥 ln (320+273) = −6,580 𝑚𝑜𝑙.𝐾
1ℎ𝑜𝑡
𝐽
(b) ∆𝑆𝑡𝑜𝑡𝑎𝑙 = ∆𝑆𝑐𝑜𝑙𝑑 + ∆𝑆ℎ𝑜𝑡 = 8,730 + (−6,580) = 2,15 𝑚𝑜𝑙.𝐾
(c) For counter current
∆𝑇𝑐𝑜𝑙𝑑 = ∆𝑇ℎ𝑜𝑡
𝑇2𝑐𝑜𝑙𝑑 − 𝑇1𝑐𝑜𝑙𝑑 = 𝑇1𝐻𝑜𝑡 − 𝑇2 𝐻𝑜𝑡
𝑇2 𝐻𝑜𝑡 = 200 − 190 + 70 = 80𝑜 𝐶
𝑇2𝑐𝑜𝑙𝑑 190 + 273 𝐽
(𝑎)∆𝑆𝑐𝑜𝑙𝑑 = 𝐶𝑃 ln = 3,5 𝑥 8,314 𝑥 ln ( ) = 8,730
𝑇1𝑐𝑜𝑙𝑑 70 + 273 𝑚𝑜𝑙. 𝐾
𝑇2ℎ𝑜𝑡 80 + 273 𝐽
∆𝑆ℎ𝑜𝑡 = 𝐶𝑃 ln = 3,5 𝑥 8,314 𝑥 ln ( ) = −8,515
𝑇1ℎ𝑜𝑡 200 + 273 𝑚𝑜𝑙. 𝐾
𝐽
(𝑏)∆𝑆𝑡𝑜𝑡𝑎𝑙 = ∆𝑆𝑐𝑜𝑙𝑑 + ∆𝑆ℎ𝑜𝑡 = 8,730 + (−8,515) = 0,215
𝑚𝑜𝑙. 𝐾
Read: Introduction to Chemical Engineering Thermodynamics 7th ed (J.M Smith, Van N
ess, Abbott) example 5.9

2.Consider two reversible heat engines where the heat flow is arranged in series. The first
engine A has heat addition at 400oC and heat rejection at temperature T. The second heat
engine B receives at temperature T the heat rejected by first engine, and in turn has heat
rejection at 5oC. Calculate the temperature T, in degrees Celsius, for the situation where
(a) the work outputs of the two engines are equal and (b) the thermal efficiency if the two
engines are equal!
Solution:

THA=400oC
(a) if WA=WB Find T
QHA 𝑊𝐴 = 𝑊𝐵
𝑄𝐻𝐴 − 𝑄𝐶𝐴 = 𝑄𝐻𝐵 − 𝑄𝐶𝐵 … (i)
WA |𝑄 | 𝑇
Recall Carnot Equation: |𝑄𝐻| = 𝑇𝐻
A 𝐶 𝐶
|𝑄𝐻𝐴 | 𝑇𝐻𝐴 𝑇𝐻𝐴
QCA Engine A |𝑄𝐶𝐴 |
= 𝑄𝐻𝐴 = 𝑄𝐶𝐴
𝑇 𝑇
|𝑄𝐻𝐵 | 𝑇 𝑇𝐶𝐵
Engine B |𝑄𝐶𝐵 |
=𝑇 𝑄𝐶𝐵 = 𝑄𝐻𝐵
T 𝐶𝐵 𝑇

QHB Substitusi ke (i)


𝑇𝐻𝐴 𝑇𝐶𝐵
WB 𝑄 𝐶𝐴 − 𝑄𝐶𝐴 = 𝑄𝐻𝐵 − 𝑄𝐻𝐵
𝑇 𝑇
𝑇 𝑇𝐶𝐵
B 𝑄𝐶𝐴 ( 𝐻𝐴 − 1) = 𝑄𝐻𝐵 (1 − )
𝑇 𝑇
QCB Since QCA = QHB
𝑇 𝑇𝐶𝐵
( 𝐻𝐴 + )=2
𝑇 𝑇
TCB= 5oC (673+278)
𝑇= = 475,5 𝐾
2
𝑜
𝑇 = 202,5 𝐶

(b) if ηA=ηB Find T


𝑇
Recall Carnot Equation: 𝜂 = 1 − 𝑇 𝐶
𝐻
𝑇
Engine A: 𝜂𝐴 = 1 − 𝑇
𝐻𝐴
𝑇𝐶𝐵
Engine B: 𝜂𝐵 = 1 − 𝑇
𝜂𝐴 = 𝜂𝐵
𝑇 𝑇𝐶𝐵
1− = 1−
𝑇𝐻𝐴 𝑇
𝑇 = √𝑇𝐶𝐵 . 𝑇𝐻𝐴 = √673𝑥 278 = 432,54 𝐾
𝑇 = 159,54𝑜 𝐶
3.Consider steam generation in a boiler using flue gas (gas from combustion) at heat
source. Liquid water enters the boiler at 100oC and leaves at 100oC as saturated steam x
= 100%. Due to heat release for the steam production, the temperature of the flue gas
decreases from 1110oC to 150oC. The flue gas heat capacity is given by: Cp/R = 3,83 +
0,000551 T (K), latent heat of vaporization of water = 2257 kJ/kg. (a) With references to
a surrounding temperature of 25oC, what is the lost work of this process in kJ/mol of flue
gas? (b) With references to surrounding temperature of 25oC, what is the maximum work
in kJ/mol of flue gas that can be accomplished by the saturated steam at 100 oC if it
condenses only (does not cool)? Flue Gas
150oC
Flue Gas
1100oC Saturated
liquid 100oC
Saturated vapor 100oC
Saturated liquid 100oC
Condenser

Wideal =?

Wlost=?
𝑘𝐽
̇ 𝑇𝜎 (
(a) 𝑊𝑙𝑜𝑠𝑡 = 𝑆𝐺 )
𝑚𝑜𝑙 𝑓𝑙𝑢𝑒 𝑔𝑎𝑠
𝑆̇𝐺
Perlu karena unit Wlost yang diminta per mol flue gas
𝑛̇ 𝑔𝑎𝑠
Entropy generation in boiler:
̇ = 𝑚̇ 𝑠𝑡𝑒𝑎𝑚 Δ𝑆𝑠𝑡𝑒𝑎𝑚 + 𝑛̇ 𝑔𝑎𝑠 Δ𝑆𝑔𝑎𝑠
Recall 𝑆𝐺
𝑆̇𝐺 𝑚̇ 𝑠𝑡𝑒𝑎𝑚
= Δ𝑆𝑠𝑡𝑒𝑎𝑚 + Δ𝑆𝑔𝑎𝑠 per mol gas
𝑛̇ 𝑔𝑎𝑠 𝑛̇ 𝑔𝑎𝑠
Δ𝐻 𝑉 2257 𝑘𝐽
Δ𝑆𝑠𝑡𝑒𝑎𝑚 = = = 6,048 ⁄𝐾. 𝑘𝑔
𝑇𝑠𝑡𝑒𝑎𝑚 (100+273,15) 𝑠𝑡𝑒𝑎𝑚
𝑇2 𝐶𝑝 𝑑𝑇 𝑃
Δ𝑆𝑔𝑎𝑠 = ∫𝑇1 𝑇 − 𝑅 ln 𝑃2 per mol gas
1
𝑇2 𝐶𝑝 𝑑𝑇
Since P2=P1  ∆𝑆𝑔𝑎𝑠 = ∫𝑇1 𝑇
𝑇2 3,83+0,000551𝑇
∆𝑆𝑔𝑎𝑠 = 𝑅 ∫𝑇1 ( ) 𝑑𝑇
𝑇
(150+273,15) (150+273,15) 𝐽
∆𝑆𝑔𝑎𝑠 = 𝑅 [3,83 ln (1100+273,15) + 0,000551 𝑇|(1100+273,15) ] = −41,835 𝐾.𝑚𝑜𝑙𝑔𝑎𝑠
𝑚̇𝑠𝑡𝑒𝑎𝑚
Energy balance untuk dapatkan
𝑛̇ 𝑔𝑎𝑠
𝑇2
Energy dilepas gas = energy diterima steam  𝑛̇ 𝑔𝑎𝑠 ∫𝑇1 𝐶𝑝 𝑑𝑇 + 𝑚̇𝑠𝑡𝑒𝑎𝑚 Δ𝐻 𝑉 = 0
𝑇2
𝑚̇𝑠𝑡𝑒𝑎𝑚 − ∫𝑇1 𝐶𝑝 𝑑𝑇
∴ =
𝑛̇ 𝑔𝑎𝑠 Δ𝐻 𝑉
Dari data: Cp/R = 3,83 + 0,000551 T
𝐶𝑝 𝑇
∴ ∫ 𝐶𝑝 𝑑𝑇 = 𝑅 ∫ 𝑑𝑇 = 𝑅 ∫𝑇 2(3,83 + 0,000551 T) dT
𝑅 1
423,15
0,000551 𝑇 2
∫ 𝐶𝑝 𝑑𝑇 = 𝑅 [3,83 𝑇 |(423,15)
(1373,15) + | ] = −34159,2 𝐽/𝑚𝑜𝑙𝑔𝑎𝑠
2 1373,15
J
Dari data: Δ𝐻 𝑉 = 2257 gram 𝑠𝑡𝑒𝑎𝑚
𝑇2
𝑚̇𝑠𝑡𝑒𝑎𝑚 − ∫𝑇1 𝐶𝑝 𝑑𝑇 −(−34159,2) 𝑔𝑟𝑎𝑚 𝑠𝑡𝑒𝑎𝑚
∴ = = = 15,135
𝑛̇ 𝑔𝑎𝑠 Δ𝐻 𝑉 2257 𝑚𝑜𝑙 𝑔𝑎𝑠
𝑆̇𝐺 𝑚̇ 𝑠𝑡𝑒𝑎𝑚
Recall: = Δ𝑆𝑠𝑡𝑒𝑎𝑚 + Δ𝑆𝑔𝑎𝑠
𝑛̇ 𝑔𝑎𝑠 𝑛̇ 𝑔𝑎𝑠
𝑆̇𝐺
𝑛̇ 𝑔𝑎𝑠
= 15,135 𝑥 6,048 − 41,835 = 49,7 𝐾.𝑚𝑜𝑙𝐽 𝑔𝑎𝑠
𝑆𝐺̇ 𝑘𝐽
𝑊𝑙𝑜𝑠𝑡 = 𝑇𝜎 = 49,7 𝑥 (25 + 273) = 14,8
𝑛̇ 𝑔𝑎𝑠 𝑚𝑜𝑙 𝑔𝑎𝑠
(b)

Saturated
Saturated vapor 100oC liquid 100oC

Condenser

Wideal per mol gas =?

𝑘𝐽
Recall: 𝑊𝑖𝑑𝑒𝑎𝑙 = ∆𝐻𝑠𝑡𝑒𝑎𝑚 − 𝑇𝜎 ∆𝑆𝑠𝑡𝑒𝑎𝑚 ( )
𝑘𝑔 𝑠𝑡𝑒𝑎𝑚
𝑘𝐽
∆𝐻𝑠𝑡𝑒𝑎𝑚 = −Δ𝐻𝑉 = −2257
𝑘𝑔 𝑠𝑡𝑒𝑎𝑚
−Δ𝐻𝑉 −2257 𝑘𝐽
∆𝑆𝑠𝑡𝑒𝑎𝑚 = = = −6,048
𝑇𝑠𝑡𝑒𝑎𝑚 (100+273) 𝐾.𝑘𝑔 𝑠𝑡𝑒𝑎𝑚
𝑊𝑖𝑑𝑒𝑎𝑙 = ∆𝐻𝑠𝑡𝑒𝑎𝑚 − 𝑇𝜎 ∆𝑆𝑠𝑡𝑒𝑎𝑚
𝑘𝐽
𝑊𝑖𝑑𝑒𝑎𝑙 = −2257 − (25 + 273,15)(−6,048) = −453,79
𝑘𝑔 𝑠𝑡𝑒𝑎𝑚
Energy balance pada condenser
𝑚̇𝑠𝑡𝑒𝑎𝑚 𝑝𝑟𝑜𝑑𝑢𝑐𝑒𝑑 = 𝑚̇𝑠𝑡𝑒𝑎𝑚 𝑐𝑜𝑛𝑑𝑒𝑛𝑠𝑒𝑑
𝑚̇
Maka 𝑛̇𝑠𝑡𝑒𝑎𝑚 sama dengam kasus a (perhitungan Wlost)
𝑔𝑎𝑠
𝑚̇𝑠𝑡𝑒𝑎𝑚 𝑔𝑟𝑎𝑚 𝑠𝑡𝑒𝑎𝑚
Recall rasio = 15,135
𝑛̇ 𝑔𝑎𝑠 𝑚𝑜𝑙 𝑔𝑎𝑠
15,135 𝑘𝑔 𝑠𝑡𝑒𝑎𝑚 𝑘𝐽
𝑊𝑖𝑑𝑒𝑎𝑙 𝑝𝑒𝑟 𝑚𝑜𝑙 𝑔𝑎𝑠 = ( ) 𝑥 (−453,79 )
1000 𝑚𝑜𝑙 𝑔𝑎𝑠 𝑘𝑔 𝑠𝑡𝑒𝑎𝑚
𝑘𝐽
𝑊𝑖𝑑𝑒𝑎𝑙 𝑝𝑒𝑟 𝑚𝑜𝑙 𝑔𝑎𝑠 = −6,86
𝑚𝑜𝑙 𝑔𝑎𝑠
TK 3081-Termodika Dasar A
Perbaikan 1 Modul 1 2009

1.Tinjau Gas panas (Flue gas) dari pembakaran metana dengan udara berlebih 20% pada
suatu combustion chamber dimanfaatkan sebagai sumber energy untuk produksi steam
yang selanjutnya digunakan sebagai input energy suatu heat engine. Input air masuk
boiler 78oF dan keluar boiler menjadi saturated vapor x=100%. Pemanfaatan energy
tersebut mengakibatkan temperature gas panas turun dari 2000oF menjadi 300oF. Steam
kemudian masuk heat exchanger dan keluar pada suhu 250 oF (x=20%). Heat engine
menghasilkan 1000HP dengan efisiensi 20%. Heat capacity gas panas: Cp/R =(3,83 +
0,000306 T), dimana T dalam K. Tentukan minimum flow rate metana (MMSCFD)
2.Tinjau suatu rangkaian piston-cylinder berisi gas Butana bertekanan 2 bar pada 350 K,
Piston ditekan pada temperature tetap hingga mencapai tekanan vapor menjadi 9,4573
bar. Dengan persamaan Redlich/Kwong tentukan (a) volume molar gas (cm3/mol) pada
piston (Diketahui sifat gas Pc = 37,96 bar Tc = 425,1 K). (b) Dapatkah kita menentukan
banyaknya mol cairan yang terbentuk dari data yang tersedia? jelaskan jawaban anda!
3.Tinjau suatu tangki pemanas air dilengkapi dengan electric heater sebagaimana
diperlihatkan gambar berikut. Pencampuran air masuk dengan air yang di dalam tangki
berlangsung instantaneous (sangat cepat) sehingga temperatur dalam tangki selalu
homogen. Pada suatu saat aliran listrik mati selama 15 menit kemudian listrik hidup lagi.
Aliran air independen dari aliran listrik. (a) Tentukan besarnya pasokan daya electric
heater (dalam kW) sebelum listrik mati (b) Tentukan temperature air keluar tangki tepat
saat listrik mulai hidup kembali. Heat capacity air = 4,2 kL/kg.K konstan independen
dari P dan T Hint: Steady state mass balance, but unsteady state energy balance.

Water 20oC 0,2 kg/s

200 kg
60oC
Electric
heater

Water 0,2 kg/s


Well insulated tank

(Kondisi awal, sebelum aliran listrik mati)


SOLUSI
TK 3081-Termodika Dasar A
Perbaikan 1 Modul 1 2009

1.Tinjau Gas panas (Flue gas) dari pembakaran metana dengan udara berlebih 20% pada
suatu combustion chamber dimanfaatkan sebagai sumber energy untuk produksi steam
yang selanjutnya digunakan sebagai input energy suatu heat engine. Input air masuk
boiler 78oF dan keluar boiler menjadi saturated vapor x=100%. Pemanfaatan energy
tersebut mengakibatkan temperature gas panas turun dari 2000oF menjadi 300oF. Steam
kemudian masuk heat exchanger dan keluar pada suhu 250oF (x=20%). Heat engine
menghasilkan 1000HP dengan efisiensi 20%. Heat capacity gas panas: Cp/R =(3,83 +
0,000306 T), dimana T dalam K. Tentukan minimum flow rate metana (MMSCFD)
Solusi:

Metana =??
1 bar, 25oC
Flue Gas
Udara berlebih 2000oF
20% 1 2 Steam X= 100 %
1 bar, 25oC

Water 78oF Steam X =20%


3 250oF
QH
1000 HP

Eff= 20%

Energy balance: Energi air di boiler = energi dilepas flue gas


𝑄̇𝑤𝑎𝑡𝑒𝑟 + 𝑄̇𝑔𝑎𝑠 = 0
𝑚̇𝑠𝑡𝑒𝑎𝑚 ΔH𝑠𝑡𝑒𝑎𝑚1−2 + 𝑛̇ 𝑓𝑙𝑢𝑒 𝑔𝑎𝑠 Δ𝐻𝑓𝑙𝑢𝑒 𝑔𝑎𝑠 = 0
𝑚̇𝑠𝑡𝑒𝑎𝑚 ΔH𝑠𝑡𝑒𝑎𝑚
𝑛̇ 𝑓𝑙𝑢𝑒 𝑔𝑎𝑠 = −Δ𝐻𝑓𝑙𝑢𝑒 𝑔𝑎𝑠
𝑚̇𝑠𝑡𝑒𝑎𝑚 Δ𝐻1−2
𝑛̇ 𝑓𝑙𝑢𝑒 𝑔𝑎𝑠 = 𝑇2 … … (𝑖)
− ∫𝑇1 𝐶𝑝 𝑑𝑇
𝑚̇𝑠𝑡𝑒𝑎𝑚 𝑑𝑎𝑛 ΔH1−2 didapat dari neraca energy heat engine dan steam table
Tinjau Heat engine
Eff = 20% ; W= 1000 HP
𝐵𝑡𝑢
𝑊 1000 𝐻𝑃
𝑄𝐻̇ = = 𝑥 1,4148𝐻𝑃
𝑠
= 3534 𝐵𝑡𝑢/𝑠
𝜂 20%
Dari sisi steam energy dilepas sehingga 𝑄̇𝑠𝑡𝑒𝑎𝑚 = −𝑄𝐻̇ = −3534 𝐵𝑡𝑢/𝑠
H2O keluar heat exchanger at 250oF dengan x = 20%
dari steam table at 250oF: HV =1164 Btu/lb HL=218,6 Btu/lb
Recall: H= (1-x)HL +x HV
H3= (1-0,2)218,6 + 0,2 x 1164 =407,7 Btu/lb
Reservoir termal beroperasi pada T konstan berarti temperature keluar boiler = T keluar
heat exchanger yaitu 250oF. Maka H2= (1-1) 218,6 + 1 x 1164 = 1164 Btu/lb
Recall: 𝑄̇𝑠𝑡𝑒𝑎𝑚 = 𝑚̇𝑠𝑡𝑒𝑎𝑚 ΔH𝑠𝑡𝑒𝑎𝑚
𝑄̇𝑠𝑡𝑒𝑎𝑚 −3534 𝑙𝑏
𝑚̇𝑠𝑡𝑒𝑎𝑚 = = = 4,67 … … (𝑖𝑖)
𝐻3 −𝐻2 407,7−1164 𝑠
Tinjau boiler:
Δ𝐻1−2 = 𝐻2 − 𝐻1
Recall H2=1164 Btu/lb (perhitungan sebelumnya)
H1= 46,04 Btu/lb (steam table liquid at 78oF)
𝐵𝑡𝑢
Δ𝐻1−2 = 1164 − 46,04 = 1117,96 … … (𝑖𝑖𝑖)
𝑙𝑏
Dari data: Cp/R = (3,83 + 0,000306 T)
𝑇 𝑇 𝑇
∴ ∫𝑇 2 𝐶𝑝 𝑑𝑇 = 𝑅 ∫𝑇 2 𝐶𝑝 𝑑𝑇 = 𝑅 ∫𝑇 2(3,83 + 0,000306 T) dT
1 1 1
𝑇2 300+460
0,000306 𝑇 2 𝐵𝑡𝑢
∫ 𝐶𝑝 𝑑𝑇 = 1,986 [3,83 𝑇 |(300+460)
(2000+460) + | ] = −14594 … … (𝑖𝑣)
𝑇1 2 2000+460
𝑙𝑏𝑚𝑜𝑙
Substitute (ii) (iii) (iv) ke (i)
4,67𝑥1117,96
𝑛̇ 𝑓𝑙𝑢𝑒 𝑔𝑎𝑠 = = 0,358 𝑙𝑏𝑚𝑜𝑙/𝑠
−(−14594)
Mass balance gas: 𝑛̇ 𝑓𝑙𝑢𝑒 𝑔𝑎𝑠 = 𝑛̇ 𝑔𝑎𝑠 𝑚𝑎𝑠𝑢𝑘 = (𝑛̇ 𝑀𝑒𝑡ℎ𝑎𝑛𝑎 + 𝑛̇ 𝑢𝑑𝑎𝑟𝑎 )
Reaksi: CH4 + 2O2 CO2 + 2H2O
Reaktan

CH4 = 1 mol; O2 stoikiometrik =2 mol; Total O2 masuk 2x120%= 2,4 mol; N2 dalam
udara = 79/21 x 2,4 = 9,028
Total mol masuk per 1 mol Methana = 1+2,4+9,028= 12,43 mol gas
𝑛 𝑛
Laju mol Methana: 𝑛̇ 𝑀𝑒𝑡ℎ𝑎𝑛𝑎 = 𝑛 𝑚𝑒𝑡ℎ𝑎𝑛𝑎 𝑥𝑛̇ 𝑔𝑎𝑠 𝑚𝑎𝑠𝑢𝑘 = 𝑛 𝑚𝑒𝑡ℎ𝑎𝑛𝑎 𝑥𝑛̇ 𝑔𝑎𝑠 𝑚𝑎𝑠𝑢𝑘
𝑔𝑎𝑠 𝑚𝑎𝑠𝑢𝑘 𝑔𝑎𝑠 𝑚𝑎𝑠𝑢𝑘
1
𝑛̇ 𝑀𝑒𝑡ℎ𝑎𝑛𝑎 = 12,43 𝑥 0,358 = 0,0288 𝑙𝑏𝑚𝑜𝑙/𝑠

Konversi ke MMSCFD
𝑝𝑠𝑖𝑎𝑓𝑡3
𝑅𝑇 10,73 𝑥 520 𝑅 𝑓𝑡 3
𝑅 𝑙𝑏𝑚𝑜𝑙
Pada kondisi standar 𝑉 = = = 379,6
𝑃 14,7 𝑝𝑠𝑖𝑎 𝑙𝑏𝑚𝑜𝑙
𝑙𝑏𝑚𝑜𝑙 𝑓𝑡 3 86400 𝑠 𝑀𝑀𝑆𝐶𝐹
𝑛̇ = 0,0288 𝑥379,6 𝑥 𝑥 = 0,94 𝑀𝑀𝑆𝐶𝐹𝐷
𝑠 𝑙𝑏𝑚𝑜𝑙 𝑑𝑎𝑦 106 𝑓𝑡 3

2.Tinjau suatu rangkaian piston-cylinder berisi gas Butana bertekanan 2 bar pada 350 K,
Piston ditekan pada temperature tetap hingga mencapai tekanan vapor menjadi 9,4573
bar. Dengan persamaan Redlich/Kwong tentukan (a) volume molar Butana (saturated
liquid) (cm3/mol) pada piston (Diketahui sifat gas Pc = 37,96 bar Tc = 425,1 K). (b)
Dapatkah kita menentukan banyaknya mol cairan yang terbentuk dari data yang tersedia?
jelaskan jawaban anda!
Solusi:

350 K; 2 bar (all vapor)

350 K; 9,4573 bar (vapor/liquid) Find


Vmolar=
𝑍𝑅𝑇
(a) Recall: 𝑉 = , Z dihitung dari hasil iterasi
𝑃
1+𝛽−𝑍𝑖
Iteration scheme for liquid 𝑍𝑖+1 = 𝛽 + [(𝑍𝑖 + 𝜖𝛽)(𝑍𝑖 + 𝜎𝛽) ] … … (𝑖)
𝑞𝛽
𝑃 𝛼(𝑇𝑟 )
Where 𝛽 = Ω 𝑇𝑟 and 𝑞 = 𝜓
𝑟 Ω𝑇𝑟
For RK: ϵ = 0 ; σ = 1 ; α(Tr)= Tr -1/2
; Ω=0,08664 ; Ψ=0,42748
𝑇 350 𝑃 9,4573
𝑇𝑟 = 𝑇 = 425,1 = 0,8233 ; 𝑃𝑟 = 𝑃 = = 0,2491
𝑐 𝐶 37,96
𝑃 0,2491
𝛽 = Ω 𝑇𝑟 = 0,08664 0,8233 = 0,026214 … … (ii)
𝑟
1

𝛼(𝑇𝑟 ) 𝑇𝑟 −1/2 0,8233 2
𝑞=𝜓 =𝜓 = 0,42748 0,08664𝑥0,8233 = 6,6048 … … (𝑖𝑖𝑖)
Ω𝑇𝑟 Ω𝑇𝑟
Substitusi (ii) dan (iii) ke (i) dan lakukan iterasi
Start with Z=β
1+0,026214−0,026214
𝑍1 = 0,026214 + [(0,026214 + 0𝑥0,026214)(0,026214 + 1𝑥0,026214) ] = 0,03415
6,6048𝑥0,026214
Z2= 0,038 Z3=0,040175…… Z= 0,04333
𝑐𝑚3 𝑏𝑎𝑟
𝑍𝑅𝑇 0,04333𝑥83,14 𝑥350 𝐾 𝑐𝑚3
Maka 𝑉 = = 𝑚𝑜𝑙 𝐾
= 133,32 𝑚𝑜𝑙
𝑃 9,4573 𝑏𝑎𝑟
(b) Setelah ditekan hingga tekanan vapor di dalam silinder terdapat 2 fasa, gas/cair
sedangkan proporsi gas /cair tidak dapat dihitung dengan data yang ada sehingga
banyaknya mol tak dapat dihitung.

Read: Introduction to Chemical Engineering Thermodynamics 7th ed (J.M Smith, Van N


ess, Abbott) example 3.9

3.Tinjau suatu tangki pemanas air dilengkapi dengan electric heater sebagaimana
diperlihatkan gambar berikut. Pencampuran air masuk dengan air yang di dalam tangki
berlangsung instantaneous (sangat cepat) sehingga temperatur dalam tangki selalu
homogen. Pada suatu saat aliran listrik mati selama 15 menit kemudian listrik hidup lagi.
Aliran air independen dari aliran listrik. (a) Tentukan besarnya pasokan daya electric
heater (dalam kW) sebelum listrik mati (b) Tentukan temperature air keluar tangki tepat
saat listrik mulai hidup kembali. Heat capacity air = 4,2 kL/kg.K konstan independen
dari P dan T Hint: Steady state mass balance, but unsteady state energy balance.
Solusi

Water 20oC 0,2 kg/s

200 kg
60oC
Electric
heater

Water 0,2 kg/s


Well insulated tank

(Kondisi awal, sebelum aliran listrik mati)


(a) Energi heater = energy yang diterima air
𝑄̇ℎ𝑒𝑎𝑡𝑒𝑟 = 𝑚̇𝐶𝑝(𝑇𝑜𝑢𝑡 − 𝑇𝑖𝑛 ) = 0,2 (4,2)(60 − 20) = 33,6 𝑘𝑊
𝑑𝑈
(b)Recall Energy balance: 𝑚𝐶𝑉 𝑑𝑇 + 𝑚̇(𝐻 − 𝐻1 ) = 𝑄̇ + 𝑊̇
No heat loss through wall, No work  𝑄̇ = 𝑊̇ = 0
𝑑𝑈
∴ 𝑚𝐶𝑉 𝑑𝑇 + 𝑚̇(𝐻 − 𝐻𝑖𝑛 ) = 0 … … (𝑖)
Water = incompressible fluid  Cv=Cp=C so, dU=C.dT & dH=C.dT
𝑑𝑈 𝑑𝑇
=𝐶 dan (𝐻 − 𝐻𝑖𝑛 ) = 𝐶 (𝑇 − 𝑇𝑖𝑛 ) where Tin = T water inlet
𝑑𝑇 𝑑𝑡
substitusi ke (i)
𝑑𝑇 𝑚 𝐶 𝑑𝑇
𝑚𝐶𝑉 𝐶 𝑑𝑡 + 𝑚̇𝐶 (𝑇 − 𝑇𝑖𝑛 ) = 0  dt = − 𝑚̇𝐶𝐶𝑉(𝑇−𝑇 ) 𝑖𝑛
𝑚𝐶𝑉 𝑑(𝑇−𝑇𝑖𝑛 )
Tin constant  dt = − (𝑇−𝑇𝑖𝑛 )
𝑚̇
𝑚𝐶𝑉 (𝑇−𝑇 )
integralkan kedua ruas didapat ∆t = − 𝑚̇
ln (𝑇 −𝑇𝑖𝑛 ) dimana To = T water saat t =0
𝑜 𝑖𝑛
𝑚̇ ∆𝑡
Solve for T: 𝑇 = 𝑇𝑖𝑛 + (𝑇𝑜 − 𝑇𝑖𝑛 ) exp (− )
𝑚𝐶𝑉
𝑘𝑔
0,2 𝑠 𝑥15𝑥60 𝑠
𝑜 𝑜
𝑇 = 20 𝐶 + (60 − 20) 𝐶 exp (− ) = 36,3 𝑜 𝐶
200 𝑘𝑔
TK 3081-Termodika Dasar A
UTS 2010

1.Tinjau suatu Heat Engine digunakan untuk menghasilkan kerja diketahui temperature
ambient air 25oC. Pada heat sink dialirkan gas bersuhu -60oC pada rate 500 MMSCFD.
Diberikan perubahan enthalpy gas 500 kJ/kg Hitunglah kerja maksimum (GW) yang
dapat dihasilkan mesin jika mesin beroperasi pada kondisi standard! (BM gas 17
lb/lbmol)
2.Tinjau suatu tangki rigid berisi gas etana pada kondisi standar (25 oC, 22 bar). Tangki
dipanasi hingga 220 oC. Dengan menggunakan generalized correlation tentukan tekanan
gas (bar) pada akhir pemanasan tersebut. Properties of ethane: 𝜔 = 1,0 𝑇𝑐 =
305,3 𝐾 𝑃𝑐 = 48,7 𝑏𝑎𝑟
3.Tinjau pembakaran metana dengan udara berlebih 20% pada suatu combustion chamber
pada kondisi standar. Panas yang dihasilkan digunakan untuk produksi steam yang
selanjutnya digunakan sebagai input energy suatu heat engine. Input air masuk chamber
35 oC (Saturated liquid) dan keluar chamber pada 100 oC (saturated Vapor). Steam yang
masuk heat engine keluar pada 100oC (Saturated liquid) Temperature flue gas 140oC.
Temperatur heat sink dari heat engine 20 oC. Tentukan minimum flow rate metana
(MMSCFD) untuk menghasilkan power heat engine 2 MW. Asumsi tidak ada heat loss
pada sistem. (latent heat of vaporization of water = 2257 kJ/kg, ΔH298=-802,625 kJ/mol
CH4)
SOLUSI
TK 3081-Termodika Dasar A
UTS 2010

1.Tinjau suatu Heat Engine digunakan untuk menghasilkan kerja diketahui temperature
ambient air 25oC. Pada heat sink dialirkan gas bersuhu -60oC pada rate 500 MMSCFD.
Diberikan perubahan enthalpy gas 500 kJ/kg Hitunglah kerja maksimum (GW) yang
dapat dihasilkan mesin jika mesin beroperasi pada kondisi standard! (BM gas 17
lb/lbmol)
Solusi:
Ambient air 25oC Max W  Carnot Engine
Recall:
Q
𝑊 (𝑄𝐻 −𝑄𝐶 ) 𝑄𝐻 𝑇𝐻
H WMAX=? = = −1= −1
𝑄𝐶 𝑄𝐶 𝑄𝐶 𝑇𝐶
𝑇
𝑊𝑚𝑎𝑥 = 𝑄𝐶 ( 𝑇𝐻 − 1)
𝐶

Where𝑄𝐶̇ = 𝑚̇ Δ𝐻 𝑉
QC

CH4

T=-60oC Gas 500 MMSCFD

𝑝𝑠𝑖𝑎 𝑓𝑡3
𝑅𝑇 (10,73 )(60+460 𝑅) 𝑓𝑡 3
𝑙𝑏𝑚𝑜𝑙 𝑅
At Standard condition: 𝑉 = = = 379,56 𝑙𝑏𝑚𝑜𝑙 (𝑆𝐶𝐹)
𝑃 14,7𝑝𝑠𝑖𝑎
500 𝑥 106
mole rate: 𝑛̇ = 500 𝑀𝑀𝑆𝐶𝐹𝐷 = 24𝑥3600𝑥379,56 = 15,24 𝑙𝑏𝑚𝑜𝑙/𝑠𝑒𝑐
mass rate:𝑚̇ = 𝑛̇ 𝑥 𝐵𝑀 = 15,24 𝑥 17 = 259 𝑙𝑏/𝑠𝑒𝑐
𝑙𝑏 𝑘𝑔
𝑚̇ = 259 𝑠𝑒𝑐 𝑥 2,2046 𝑙𝑏 = 117,5 𝑘𝑔/𝑠𝑒𝑐
𝑄𝐶̇ = 𝑚̇ Δ𝐻 𝑉 = 117,5 𝑥 500 = 58750 𝑘𝐽/𝑠𝑒𝑐
𝑇 25+273,15 𝑘𝐽
𝑊𝑚𝑎𝑥 = 𝑄𝐶̇ ( 𝐻 − 1) = 58750 ( − 1) = 23428 = 0,023 𝐺𝑊
𝑇𝐶 −60+273,15 𝑠𝑒𝑐

2.Tinjau suatu tangki rigid berisi gas etana pada kondisi standar (25 oC, 22 bar). Tangki
dipanasi hingga 220 oC. Dengan menggunakan generalized correlation tentukan tekanan
gas (bar) pada akhir pemanasan tersebut. Properties of ethane: 𝜔 = 1,0 𝑇𝑐 =
305,3 𝐾 𝑃𝑐 = 48,7 𝑏𝑎𝑟
Solusi:
Find P2!
P1, T1, P2, T2,
Z1, V1 Dipanasi Z2, V2

𝑍2 𝑅 𝑇2
𝑃2 = 𝑉2
Rigid tank = Constant Volume process V1=V2
𝑃
Recall: 𝑍2 = 1 + (𝐵 0 + 𝜔𝐵′ )2 𝑇𝑟2
𝑟2
𝑃2 𝑇2
Substitute: 𝑃𝑟2 = 𝑃 and𝑇𝑟2 = 𝑇
𝑐 𝑐
𝑃2
⁄𝑃
(1+(𝐵0 +𝜔𝐵′ )2 𝑇 𝑐 ) 𝑅 𝑇2
2⁄
𝑇𝑐
𝑃2 = 𝑉1
Rearrange
𝑅 𝑇2
∴ 𝑃2 =
𝑇
𝑉1 − (𝐵 0 + 𝜔𝐵 ′ )2 𝑅 𝑐⁄𝑃
𝑐
V1 diperoleh dari kondisi awal
𝑍1 𝑅 𝑇1 𝑃𝑟1
𝑉1 = dimana 𝑍1 = 1 + (𝐵 0 + 𝜔𝐵 ′ )1
𝑃1 𝑇𝑟1
𝑃1 22 𝑇1 25+273
𝑃𝑟1 = = = 0,4517 𝑇𝑟1 = = = 0,976
𝑃𝑐 48,7 𝑇𝑐 305,3
0,422 0,422
𝐵 0 = 0,083 − = 0,083 − 0,9761,6 = −0,35572
𝑇𝑟 1,6
0,172 0,172
𝐵 ′ = 0,139 − = 0,139 − 0,9764,2 = −0,0514
𝑇𝑟 4,2
𝑃 0,4517
𝑍1 = 1 + (𝐵 0 + 𝜔𝐵 ′ )1 𝑇𝑟1 = 1 + (−0,35572 + (1,0)(−0,0514))1 = 0,8116
𝑟1 0,976
𝑏𝑎𝑟 𝑐𝑚3
𝑍1 𝑅 𝑇1 0,8116 (83,14 ) (25+273 𝐾) 𝑐𝑚3
𝑉1 = = 𝑚𝑜𝑙 𝐾
= 914 𝑚𝑜𝑙
𝑃1 22 𝑏𝑎𝑟
Kondisi akhir
T2= 220oC
𝑇 220+273
𝑇𝑟2 = 𝑇2 = = 1,615
𝑐 305,3
0,422 0,422
𝐵 0 = 0,083 − = 0,083 − 1,6151,6 = −0,113
𝑇𝑟 1,6
0,172 0,172
𝐵 ′ = 0,139 − = 0,139 − 1,6154,2 = 0,116
𝑇𝑟 4,2
𝑅 𝑇2
Recall 𝑃2 = 𝑇
𝑉1 −(𝐵0 +𝜔𝐵′ )2 𝑅 𝑐⁄𝑃
𝑐
83,14 (220+273)
Plug in numbers 𝑃2 = = 44,92 𝑏𝑎𝑟
914−((−0,113+(1,0)(0,116))83,14305,3⁄48,7)

3.Tinjau pembakaran metana dengan udara berlebih 20% pada suatu combustion chamber
pada kondisi standar. Panas yang dihasilkan digunakan untuk produksi steam yang
selanjutnya digunakan sebagai input energy suatu heat engine. Input air masuk chamber
35 oC (Saturated liquid) dan keluar chamber pada 100 oC (saturated Vapor). Steam yang
masuk heat engine keluar pada 100oC (Saturated liquid) Temperature flue gas 140oC.
Temperatur heat sink dari heat engine 20 oC. Tentukan minimum flow rate metana
(MMSCFD) untuk menghasilkan power heat engine 2 MW. Asumsi tidak ada heat loss
pada sistem. (latent heat of vaporization of water = 2257 kJ/kg, ΔH298= -802,625 kJ/mol
CH4)
Solusi:
Metana
=??

Udara berlebih
20% Flue Gas 140oC
1 bar, 25oC
Water 35oC
Steam 100oC

Liquid water
100oC

QH

2 MW

Water 20oC

Minimun flow rate  max efisiensi heat engine (Carnot Engine)


Recall: Carnot Equation:
𝑇 20+273 𝑊 2𝑥106
𝜂 = 1− 𝐶 = 1− = 0,214 𝑄𝐻̇ = = = 9325 𝑘𝐽/𝑠
𝑇𝐻 100+273 𝜂 0,214
𝑄𝐻̇ = 𝑚̇𝑠𝑡𝑒𝑎𝑚 Δ𝐻𝑣
𝑄̇ 9325
𝑚̇𝑠𝑡𝑒𝑎𝑚 = Δ𝐻𝐻𝑣 = 2257 = 4,131 𝑘𝑔/𝑠
Energy balance chamber: Kalor hasil pembakaran digunakan untuk memanasi flue gas
dan memanasi air menjadi steam
𝑜
𝑛̇ (Δ𝐻298 + Δ𝐻𝑝𝑜 ) + 𝑄̇𝑤𝑎𝑡𝑒𝑟 = 0

Kalor diterima air: 𝑄̇𝑤𝑎𝑡𝑒𝑟 = 𝑚̇𝑠𝑡𝑒𝑎𝑚 (𝐶𝑝. Δ𝑇 + Δ𝐻𝑣 )


𝑄̇𝑤𝑎𝑡𝑒𝑟 = 4,131 𝑥(4,18. (100 − 35) + 2257) = 10447 𝑘𝐽/𝑠
Perhitungan ΔHp (kalor untuk memanasi flue gas)
Persamaan reaksi: CH4+ 2O2CO2+ 2H2O
Reaktan:
CH4 = 1 mol; O2 stoikiometrik =2 mol; Total O2 masuk 2x120%= 2,4 mol;
N2 dalam udara = 79/21 x 2,4 = 9,0286
Produk:
CO2 = 1mol; H2O = 2 mol; excess air = O2 masuk - O2 stoikiometrik = 2,4 -2= 0,4
mol; Inert N2 dalam udara = 9,0286 mol
Recall: ΔHp = <Cpo> (T-To)
〈𝐶𝑝𝑜 〉 ∑ 𝑛𝑖 𝐵𝑖 ∑ 𝑛𝑖 𝐶𝑖 2 2 ∑ 𝑛𝑖 𝐷𝑖
= [∑ 𝑛𝑖 𝐴𝑖 + 𝑇0 (𝜏 + 1) + 𝑇𝑜 (𝜏 + 𝜏 + 1) + ]
𝑅 2 3 𝜏 𝑇𝑜 2
Produk Mol A B C D
H2O 2 3,47 0,00145 … 12.100
CO2 1 5,457 0,001045 … -115.700
O2 0,4 3,639 0,000506 … -22.700
N2 9,0286 3,28 0,000593 … 4000

∑ 𝑛𝑖 𝐴𝑖 = (2 𝑥 3,47 + 1 𝑥 5,457 + 0,4 𝑥 3,639 + 9,0286 𝑥 3,28) = 43,47


Similarly: ∑ 𝑛𝑖 𝐵𝑖 = 0,009502 ; ∑ 𝑛𝑖 𝐶𝑖 = 0 ; ∑ 𝑛𝑖 𝐷𝑖 = −64465
𝑇 140+273
𝜏 = 𝑇 = 25+273 = 1,386
𝑜
〈𝐶𝑝𝑜 〉 ∑ 𝑛𝑖 𝐵𝑖 ∑ 𝑛𝑖 𝐶𝑖 ∑ 𝑛𝑖 𝐷𝑖
Maka, = [∑ 𝑛𝑖 𝐴𝑖 + 𝑇𝑜 (𝜏 + 1) + 𝑇𝑜 2 (𝜏 2 + 𝜏 + 1) + ]
𝑅 2 3 𝜏 𝑇𝑜 2
〈𝐶𝑝𝑜 〉 0,009502 −64465
= 43,47 + (25 + 273)(1,386 + 1) + 0 + 1,386𝑥(25+273)2 = 46,325
𝑅 2
〈𝐶𝑝𝑜 〉 = 46,325 𝑥 𝑅 = 46,325 𝑥 8,314 = 385,1
J 𝑘𝐽
Δ𝐻𝑝𝑜 = 〈𝐶𝑝𝑜 〉(T − 𝑇𝑜 ) = 385,1x(140 − 25) = 44287 = 44,287
mol 𝑚𝑜𝑙
𝑜
Recall: 𝑛̇ (Δ𝐻298 + Δ𝐻𝑝𝑜 ) + 𝑄̇ =0 𝑤𝑎𝑡𝑒𝑟
−𝑄̇ 𝑤𝑎𝑡𝑒𝑟 −10447 𝑘𝐽/𝑠
𝑛̇ = 𝑜 +Δ𝐻 𝑜 ) =( = 13,777 𝑚𝑜𝑙/𝑠
(Δ𝐻298 𝑝 −802,625+44,287)𝑘𝐽/𝑚𝑜𝑙
Konversi ke MMSCFD
𝑝𝑠𝑖𝑎𝑓𝑡3
𝑅𝑇 10,73 𝑥 520 𝑅 𝑓𝑡 3
𝑅 𝑙𝑏𝑚𝑜𝑙
𝑉= = = 379,6
𝑃 14,7 𝑝𝑠𝑖𝑎 𝑙𝑏𝑚𝑜𝑙
𝑚𝑜𝑙 𝑙𝑏𝑚𝑜𝑙 𝑓𝑡 3 86400 𝑠 𝑀𝑀𝑆𝐶𝐹
𝑛̇ = 13,777 𝑥 𝑥379,6 𝑥 𝑥 = 0,996 𝑀𝑀𝑆𝐶𝐹𝐷
𝑠 453,59 𝑚𝑜𝑙 𝑙𝑏𝑚𝑜𝑙 𝑑𝑎𝑦 106 𝑓𝑡 3
TK 3081-Termodika Dasar A
Perbaikan 3 Modul 1 2010

1. Tinjau suatu tangki baja 0,35 m3 berisi gas etana pada 25oC, 2200 Kpa. Tentukan
tekanan gas jika gas tersebut dipanasi hingga 220oC . Gunakan Pitzer Correlation for
2nd virial coefficient! Properties of ethane: BM = 30 gr/mol; Tc= 305,3 K ; Pc = 48,7
bar; Vc = 145,5 cm3/mol; Zc = 0,279.
2. Tinjau produksi steam dengan menggunakan gas hasil pembakaran metana dengan
udara berlebih 20%. Metana dan udara masuk combustion chamber pada 25oC 1 bar.
Kalor yang diserap pada produksi steam 6000 kJ/s. Temperature flue gas 140oC 1 bar.
Karena insulasi buruk terjadi heat loss melalui dinding combustion chamber. Pada
kondisi tersebut laju konsumsi gas 1 MMSCFD. Melalui perbaikan insulasi, Mr.
Jhonny berhasil menurunkan heat loss menjadi 500 kJ/s dan meningkatkan produksi
steam menjadi ekuivalen dengan penyerapan kalor sebesar 7000 kJ/s. Perbaikan
insulasi tidak mengubah temperature flue gas dan excess air tetap 20% Jika harga
methane 10 US$/MSCF, tentukan besarnya penghematan biaya gas per hari yang dapat
dicapai dari perbaikan insulasi tersebut!

CH4 + 2O2 CO2 + 2H2O ΔHo298 = -802.625 J/molCH4

3. A refrigerant unit is used to cool air at 25oC and 1 atm to -8oC at rate of 3000 m3/hr.
What is the minimum power requirement (kW) when the temperature of the
surrounding is 25oC?
SOLUSI
TK 3081-Termodika Dasar A
Perbaikan 3 Modul 1 2010

1. Tinjau suatu tangki baja 0,35 m3 berisi gas etana pada 25oC, 2200 kPa. Tentukan tekanan
gas jika gas tersebut dipanasi hingga 220oC . Gunakan Pitzer Correlation for 2nd virial
coefficient! Properties of ethane: BM = 30 gr/mol; Tc= 305,3 K ; Pc = 48,7 bar; Vc =
145,5 cm3/mol; Zc = 0,279.
Solusi:
Find P2!
Vt= 0,35 m3 Vt= 0,35 m3
25oC 2200 Dipanasi 220oC
kPa
P =??

𝑍2 𝑛2 𝑅 𝑇2
𝑃2 = tangki baja = Constant Volume process V1=V2=Vt
𝑉2 𝑡

𝑃
Recall: 𝑍1 = 1 + (𝐵 0 + 𝜔𝐵 ′ )1 𝑇𝑟1
𝑟1
P1= 2200 kPa  22 bar
𝑃 22 𝑇 25+273
𝑃𝑟1 = 𝑃1 = 48,7 = 0,452 𝑇𝑟1 = 𝑇1 = = 0,976
𝑐 𝑐 305,3
0,422 0,422
𝐵 0 = 0,083 − = 0,083 − 0,9761,6 = −0,356
𝑇𝑟 1,6
0,172 0,172
𝐵 ′ = 0,139 − = 0,139 − 0,9764,2 = −0,051
𝑇𝑟 4,2
𝑃 0,4517
𝑍1 = 1 + (𝐵 0 + 𝜔𝐵 ′ )1 𝑇𝑟1 = 1 + (−0,35572 + (1,0)(−0,0514))1 = 0,812
𝑟1 0,976
Tentukan jumlah mol ethane (n)
𝑐𝑚3
𝑃1 𝑉 𝑡 22𝑏𝑎𝑟 𝑥 0,35 𝑚3 𝑥 106
𝑚3
𝑛1 = 𝑍 = 𝑐𝑚3 𝑏𝑎𝑟
= 382,74 𝑚𝑜𝑙
1 𝑅 𝑇1 0,812 𝑥 83,14 𝑥 (25+273)𝐾
𝐾 𝑚𝑜𝑙
karena volume constant maka n1 = n2 = 382,74 mol
Kondisi akhir
T2= 220oC
𝑇 220+273
𝑇𝑟2 = 𝑇2 = = 1,615
𝑐 305,3
0,422 0,422
𝐵 0 = 0,083 − 1,6 = 0,083 − 1,6151,6 = −0,113
𝑇𝑟
′ 0,172 0,172
𝐵 = 0,139 − 4,2 = 0,139 − 1,6154,2 = 0,116
𝑇𝑟
𝑃 𝑃
𝑍2 = 1 + (𝐵 + 𝜔𝐵 ′ )2 𝑇𝑟2 = 1 + (−0,113 + (1,0)(0,116))1 1,615
0 𝑟2
𝑟2
𝑍2 = 1 + 1,857𝑥10−3 𝑃𝑟2
𝑍2 𝑛2 𝑅 𝑇2
Recall: 𝑃2 = 𝑉2 𝑡
Pr2 = P2/Pc  P2 = Pr2 x 48,7
𝑍2 𝑛2 𝑅 𝑇2
𝑃2 = 𝑉2 𝑡
𝑐𝑚3 𝑏𝑎𝑟
(1+1,857𝑥10−3 𝑃𝑟2 ) 𝑥 83,14 𝑥382,74 𝑚𝑜𝑙 𝑥(220+273 𝐾)
𝑃𝑟2 𝑥 48,7 = 𝐾 𝑚𝑜𝑙
𝑐𝑚3
0,35 𝑚3 𝑥 106 3
𝑚
48,7𝑃𝑟2 = (1 + 1,857𝑥10−3 𝑃𝑟2 ) (44,82)
Rearrange and solve for Pr2
𝑃𝑟2 = 0,9219
Maka 𝑃2 = 𝑃𝑟2 x 𝑃𝑐 = 0,9219 x 48,7 = 44,90 bar

2. Tinjau produksi steam dengan menggunakan gas hasil pembakaran metana dengan
udara berlebih 20%. Metana dan udara masuk combustion chamber pada 25oC 1 bar.
Kalor yang diserap pada produksi steam 6000 kJ/s. Temperature flue gas 140oC 1 bar.
Karena insulasi buruk terjadi heat loss melalui dinding combustion chamber. Pada
kondisi tersebut laju konsumsi gas 1 MMSCFD. Melalui perbaikan insulasi, Mr. Jhonny
berhasil menurunkan heat loss menjadi 500 kJ/s dan meningkatkan produksi steam
menjadi ekuivalen dengan penyerapan kalor sebesar 7000 kJ/s. Perbaikan insulasi tidak
mengubah temperature flue gas dan excess air tetap 20% Jika harga methane 10
US$/MSCF, tentukan besarnya penghematan biaya gas per hari yang dapat dicapai dari
perbaikan insulasi tersebut!

CH4 + 2O2 CO2 + 2H2O ΔHo298 = -802625 J/molCH4


Solusi:
Sebelum perbaikan insulasi
Q̇loss
Metana
1MMSCFD
1 bar, 25oC Flue Gas
140oC
Udara
berlebih
20%
1 bar, 25oC
Q̇production steam =
6000 kJ/s
Sesudah perbaikan insulasi
Q̇loss=500 kJ/s
Metana
1 bar,
25oC Flue Gas
140oC
Udara
berlebih
20%
1 bar, 25oC
Q̇production steam =
7000 kJ/s
Analisis setelah insulasi diperbaiki
Neraca energy:Kalor pembakaran digunakan untuk produksi steam, menaikkan suhu
flue gas dan sebagian hilang karena loss
𝑄̇𝑐𝑜𝑚𝑏𝑢𝑠𝑡𝑖𝑜𝑛 + 𝑄̇𝑓𝑙𝑢𝑒 𝑔𝑎𝑠 + 𝑄̇𝑠𝑡𝑒𝑎𝑚 𝑝𝑟𝑜𝑑𝑢𝑐𝑡𝑖𝑜𝑛 + 𝑄̇𝑙𝑜𝑠𝑠 = 0
𝑜
𝑛̇ Δ𝐻298 + 𝑛̇ Δ𝐻𝑝𝑜 + 𝑄̇𝑠𝑡𝑒𝑎𝑚 𝑝𝑟𝑜𝑑𝑢𝑐𝑡𝑖𝑜𝑛 + 𝑄̇𝑙𝑜𝑠𝑠 = 0
Perhitungan ΔHp (kalor untuk memanasi flue gas)
Persamaan reaksi: CH4+ 2O2CO2+ 2H2O
Reaktan:
CH4 = 1 mol; O2 stoikiometrik =2 mol; Total O2 masuk 2x120%= 2,4 mol; N2 dalam
udara = 79/21 x 2,4 = 9,0286
Produk:
CO2 = 1mol; H2O = 2 mol; excess air = O2 masuk - O2 stoikiometrik = 2,4 -2= 0,4 mol;
Inert N2 dalam udara = 9,0286 mol
Recall: ΔHp = <Cpo> (T-To)
〈𝐶𝑝𝑜 〉 ∑ 𝑛𝑖 𝐵𝑖 ∑ 𝑛𝑖 𝐶𝑖 2 2 ∑ 𝑛𝑖 𝐷𝑖
= [∑ 𝑛𝑖 𝐴𝑖 + (𝜏 + 1) + 𝑇𝑜 (𝜏 + 𝜏 + 1) + ]
𝑅 2 3 𝜏 𝑇𝑜 2

Produk Mol A B C D
H2O 2 3,47 0,00145 … 12.100
CO2 1 5,457 0,001045 … -115.700
O2 0,4 3,639 0,000506 … -22.700
N2 9,0286 3,28 0,000593 … 4000

∑ 𝑛𝑖 𝐴𝑖 = (2 𝑥 3,47 + 1 𝑥 5,457 + 0,4 𝑥 3,639 + 9,0286 𝑥 3,28) = 43,47


Similarly: ∑ 𝑛𝑖 𝐵𝑖 = 0,009502 ; ∑ 𝑛𝑖 𝐶𝑖 = 0 ; ∑ 𝑛𝑖 𝐷𝑖 = −64465
𝑇 140+273
𝜏 = 𝑇 = 25+273 = 1,386
𝑜
〈𝐶𝑝𝑜 〉 ∑ 𝑛𝑖 𝐵𝑖 ∑ 𝑛𝑖 𝐶𝑖 ∑ 𝑛𝑖 𝐷𝑖
Maka, = [∑ 𝑛𝑖 𝐴𝑖 + 𝑇𝑜 (𝜏 + 1) + 𝑇𝑜 2 (𝜏 2 + 𝜏 + 1) + ]
𝑅 2 3 𝜏 𝑇𝑜 2
〈𝐶𝑝𝑜 〉 0,009502 −64465
= 43,47 + (25 + 273)(1,386 + 1) + 0 + = 46,32
𝑅 2 1,386𝑥(25+273)2
〈𝐶𝑝𝑜 〉
= 46,32 𝑥 𝑅 = 46,32 𝑥 8,314 = 385,1
J 𝑘𝐽
Δ𝐻𝑝𝑜= 〈𝐶𝑝𝑜 〉(T
− 𝑇𝑜 ) = 385,1x(140 − 25) = 44286,5 mol = 44,29 𝑚𝑜𝑙
𝑜
Recall: 𝑛̇ (Δ𝐻298 + Δ𝐻𝑝𝑜 ) + 𝑄̇𝑠𝑡𝑒𝑎𝑚 𝑝𝑟𝑜𝑑𝑢𝑐𝑡𝑖𝑜𝑛 + 𝑄̇𝑙𝑜𝑠𝑠 = 0
𝑘𝐽 𝑘𝐽
−𝑄̇ 𝑤𝑎𝑡𝑒𝑟 −𝑄̇ 𝑙𝑜𝑠𝑠 −7000 −500 𝑚𝑜𝑙
𝑛̇ = 𝑜 +Δ𝐻 𝑜 ) =( 𝑠 𝑠
= 9,89
(Δ𝐻298 𝑝 −802,625+44,29)𝑘𝐽/𝑚𝑜𝑙 𝑠
Konversi ke MMSCFD
𝑝𝑠𝑖𝑎𝑓𝑡3
𝑅𝑇 10,73 𝑥 520 𝑅 𝑓𝑡 3
𝑅 𝑙𝑏𝑚𝑜𝑙
𝑉= = = 379,6 𝑛̇ =
𝑃 14,7 𝑝𝑠𝑖𝑎 𝑙𝑏𝑚𝑜𝑙
𝑚𝑜𝑙 𝑙𝑏𝑚𝑜𝑙 𝑓𝑡 3 86400 𝑠 𝑀𝑀𝑆𝐶𝐹
9,89 𝑥 𝑥379,6 𝑥 𝑥 = 0,715 𝑀𝑀𝑆𝐶𝐹𝐷
𝑠 453,59 𝑚𝑜𝑙 𝑙𝑏𝑚𝑜𝑙 𝑑𝑎𝑦 106 𝑓𝑡 3
Penghematan yang dilakukan setelah perbaikan:
Laju gas yang dihemat: ṅ1 -ṅ2 = 1- 0,715 = 0,285 MMSCFD =285 MSCFD
Penghematan: laju gas x harga gas= 285 MSCFD x 10 US$/MSCFD = 2850 US$
3. A refrigerant unit is used to cool air at 25oC and 1 atm to -8oC at rate of 3000 m3/hr.
What is the minimum power requirement (kW) when the temperature of the surrounding
is 25oC?
Solusi:
Minimum power  ideal gas
𝑊̇𝑖𝑑𝑒𝑎𝑙 = 𝑛̇ (∆𝐻 − 𝑇𝜎 ∆𝑆)
𝑚3 106 𝑐𝑚3 ℎ𝑟
𝑃𝑉 1𝑎𝑡𝑚 𝑥 3000 𝑥 𝑥
ℎ𝑟 𝑚3 3600 𝑠
𝑛̇ = 𝑅 𝑇 = 𝑐𝑚3 𝑎𝑡𝑚
= 34,08 𝑚𝑜𝑙/𝑠
1 82,06 .(25+273 𝐾)
𝑚𝑜𝑙 𝐾
𝑇2 𝑖𝑔
Recall: Δ𝐻 = ∫𝑇 𝐶𝑝 𝑑𝑇
1
𝑇2
𝐶𝑝𝑖𝑔 𝐵 𝐶 𝐷
∫ 𝑑𝑇 = [𝐴 + 𝑇𝑜 (𝜏 + 1) + 𝑇𝑜 2 (𝜏 2 + 𝜏 + 1) + ] (𝑇 − 𝑇0 )
𝑇1 𝑅 2 3 𝜏𝑇𝑜 2
𝑇 −8+273
𝜏= = = 0,889
𝑇𝑜 25+273
Properties Udara: A= 3,355; B= 0,000575; C=0; D=-1600 (dari table C.1)
𝑇2
𝐶𝑝𝑖𝑔 0,000575 −1600
∫ 𝑑𝑇 = [3,355 + 298(0,889 + 1) + 0 + ] (−8 − 25)
𝑇1 𝑅 2 0,889𝑥2982
𝑇2 𝐶𝑝𝑖𝑔
∫𝑇 𝑑𝑇 = −115,39
1 𝑅
𝑇 𝐶𝑝𝑖𝑔
Δ𝐻 = 𝑅 ∫𝑇 2 𝑑𝑇 = −115,39 𝑥 8,314 = −959,36 𝐽/𝑚𝑜𝑙
1 𝑅
Δ𝑆 𝑇2 𝐶𝑝𝑖𝑔 𝑑𝑇 𝑃
Recall: = ∫𝑇 𝑅 𝑇 − ln
𝑅 1 𝑃𝑜
𝑃
For constant pressure case ln 𝑃 = 0
𝑜
𝑇2 𝐶𝑝𝑖𝑔 𝑑𝑇 𝐷 𝜏+1
∫𝑇 𝑅 𝑇 = 𝐴 ln 𝜏 + [𝐵𝑇0 + (𝐶𝑇𝑜 2 + 𝜏2 𝑇 2 ) ( )] (𝜏 − 1)
1 𝑜 2
−1600 0,889+1
= 3,355 ln 0,889 + [0,000575𝑥298 + (0 + 0,8892 2982) ( )] (0,889 − 1)
2
𝑇2 𝐶𝑝𝑖𝑔 𝑑𝑇
∫𝑇 = −0,41
1 𝑅 𝑇
𝑇 𝐶𝑝𝑖𝑔 𝑑𝑇 𝐽
Δ𝑆 = 𝑅 ∫𝑇 2 𝑅 = 8,314 𝑥 − 0,41 = −3,41 𝐾.𝑚𝑜𝑙
1 𝑇
Plug in number
𝑊̇𝑖𝑑𝑒𝑎𝑙 = 𝑛̇ (∆𝐻 − 𝑇𝜎 ∆𝑆)
𝑚𝑜𝑙 𝐽
𝑊̇𝑖𝑑𝑒𝑎𝑙 == 34,08 𝐽 𝐽 = 1936,46 = 1,94 𝑘𝑊
𝑠(−959,36 −(25+273)𝐾(−3,41) ) 𝑠
𝑚𝑜𝑙 𝐾.𝑚𝑜𝑙
TK 3081-Termodika Dasar A
UTS 2013/2014

1. Tinjau suatu tangki rigid 5 m3 berisi gas A dengan tekanan 500 kPa gage dan
temperature 20 oC. Tekanan atmosfer 100 kPa. Pada suatu saat valve tangki dibuka
sebagian sehingga tekanan gas turun. Tidak ada perpindahan kalor melalui dinding
tangki. Temperature akhir tidak diketahui namun relasi energy internal vs temperature
diketahui yaitu U (Kj/kg) = 3,115 T (K). Kontribusi perubahan energy kinetic dan
potensial dalam neraca energy tidak signifikan. Property gas dalam tangki homogen.
BM gas = 4 gram/mol. Dengan pendekatan gas ideal tentukan massa gas yang tealah
keluar pada saat tekanan tangki telah menjadi 200 kPa gage. Hint: Penurunan energy
internal dalam tangki = energy internal keluar tangki oleh aliran massa sebesar 𝛿𝑚 +
flow work oleh mass sebesar 𝛿𝑚, dimana 𝛿𝑚 = 𝑖𝑛𝑓𝑖𝑛𝑖𝑡𝑒𝑠𝑖𝑚𝑎𝑙 𝑚𝑎𝑠𝑠
2. Tinjau suatu rangkaian piston-cylinder 20 liter berisi gas etana pada kondisi standar (15
o
C, 1 atm). Piston ditekan sambil dipanasi sehingga volume gas menjadi 1 liter dan
temperature 300 oC. Dengan menggunakan generalized correlation tentukan tekanan
gas (atm) pada akhir kompresi+pemanasan tersebut. Properties of ethane: 𝜔 =
1,0 𝑇𝑐 = 305,3 𝐾 𝑃𝑐 = 48 𝑎𝑡𝑚 𝑉𝑐 = 145,5 𝑐𝑚3 /𝑚𝑜𝑙
3. Tinjau pembakaran metana dengan udara berlebih 20% pada suatu combustion
chamber. Panas yang dihasilkan digunakan untuk produksi steam yang selanjutnya
digunakan sebagai input energy suatu heat engine. Air untuk produksi steam terlebih
dahulu dilewatkan suatu preheater memanfaatkan gas buang keluar combustion
chamber. Input air masuk preheater 60 oC (Saturated liquid) dan keluar chamber pada
200 oC (saturated Vapor). Temperatur heat sink dari heat engine 20 oC. (a) Tentukan
minimum flow rate metana (mol/detik) untuk menghasilkan power heat engine 5 MW.
(b) Tentukan thermal efficiency keseluruhan system. (c) Dengan sedikit modifikasi
system akan dapat beroperasi dengan output 5MW tapi dengan flow rate metana yang
lebih rendah dibandingkan (a). Usulkan modifikasi tersebut dan jelaskan mengapa
modifikasi usulan anda akan dapat menurunkan flow rate metana. Note: Kondisi
operasi heat engine tidak dimodifikasi, tetap sama seperti pada (a).
4. Gas panas dari suatu cerobong dimanfaatkan sebagai sumber energy untuk produksi
steam, dari saturated liquid 100 oC menjadi saturated vapor 100 oC. Pemanfaatan
energy tersebut mengakibatkan temperature gas cerobong turun dari 1100 oC menjadi
150 oC. Heat capacity gas cerobong: Cp = R(3,83 + 0,000551 T), dimana T dalam K.
Dengan menggunakan temperature lingkungan 25 oC sebagai referensi, tentukan (a)
besarnya lost work proses tersebut dalam kJ/mol gas panas? (b) besarnya maksimum
work yang dapat diperoleh jika steam mengalami kondensasi menjadi saturated liquid
(dalam kJ/mol gas panas). Diketahui kalor latent penguapan air = 2257 kJ/kg.
SOLUSI
TK 3081-Termodika Dasar A
UTS 2013/2014

1. Tinjau suatu tangki rigid 5 m3 berisi gas A dengan tekanan 500 kPa gage dan
temperature 20 oC. Tekanan atmosfer 100 kPa. Pada suatu saat valve tangki dibuka
sebagian sehingga tekanan gas turun. Tidak ada perpindahan kalor melalui dinding
tangki. Temperature akhir tidak diketahui namun relasi energy internal vs temperature
diketahui yaitu U (Kj/kg) = 3,115 T (K). Kontribusi perubahan energy kinetic dan
potensial dalam neraca energy tidak signifikan. Property gas dalam tangki homogen.
BM gas = 4 gram/mol. Dengan pendekatan gas ideal tentukan massa gas yang tealah
keluar pada saat tekanan tangki telah menjadi 200 kPa gage. Hint: Penurunan energy
internal dalam tangki = energy internal keluar tangki oleh aliran massa sebesar 𝛿𝑚 +
flow work oleh mass sebesar 𝛿𝑚, dimana 𝛿𝑚 = 𝑖𝑛𝑓𝑖𝑛𝑖𝑡𝑒𝑠𝑖𝑚𝑎𝑙 𝑚𝑎𝑠𝑠
Solusi:

State 1 P atm = 100 kPA State 2


5 m3 U=3,115 T 5 m3
500 kPa gage 200 kPa gage
Mass out=??
20 oC 20 oC
Mass balance: Mass keluar = Mass awal – Mass akhir

Mass awal dihitung dengan gas ideal (P V T diketahui)


𝑃1 𝑉1
𝑚1 = … … (𝑖)
𝑅𝑇1

Mass akhir dihitung dari relasi mass dengan pressure yang diturunkan dari neraca
energy berikut:

𝑑𝑈 = 𝑢𝑑𝑚 + 𝑃𝑣𝑑𝑚 𝑑(𝑚𝑢) = 𝑢𝑑𝑚 + 𝑃𝑣𝑑𝑚

U = internal energy total; u= internal energy per unit mass; Pv=flow work per unit mass

𝑑(𝑚𝑢) = 𝑢𝑑𝑚 + 𝑃𝑣𝑑𝑚  𝑢𝑑𝑚 + 𝑚𝑑𝑢 = 𝑢𝑑𝑚 + 𝑃𝑣𝑑𝑚 𝑚𝑑𝑢 = 𝑃𝑣𝑑𝑚

u= 3,115T  du=3,115 𝑚 3,115𝑑𝑇 = 𝑃𝑣𝑑𝑚


𝑃𝑣 𝑑(𝑃𝑣) 𝑑(𝑃𝑣) 3,115 𝑑(𝑃𝑣) 𝑑𝑚
Gas Ideal 𝑇 =  𝑑𝑇 = 𝑅
𝑚 3,115 𝑅
= 𝑃𝑣𝑑𝑚 ∴ 𝑅 𝑃𝑣
= 𝑚
𝑅

v adalah specific volume, vol per unit mass. Karena persamaan berbasis massa maka
R harus dinyatakan dalam massa:
𝑘𝐽 𝑘𝐽 𝑘𝐽
𝑅 = 8,314 𝑘𝑚𝑜𝑙.𝐾 BM=4  𝑅 = 8,314 𝑘𝑔 = 2,0785 𝑘𝑔.𝐾
𝑘𝑚𝑜𝑙 𝑥4 .𝐾
𝑘𝑚𝑜𝑙

3,115 3,115 3,115 𝑑(𝑃𝑣) 𝑑𝑚 𝑑(𝑃𝑣) 𝑑𝑚


Maka, = 2,0785 = 1,5  =  1,5 =
𝑅 𝑅 𝑃𝑣 𝑚 𝑃𝑣 𝑚

𝑃2 𝑣2 𝑚 𝑃 𝑣 1,5 𝑚
Integrasi kedua ruas 1,5 ln = ln 𝑚2 (𝑃2 𝑣2 ) = 𝑚2
𝑃1 𝑣1 1 1 1 1

𝑃 𝑉 /𝑚 1,5 𝑚
v= Vol/mass  (𝑃2𝑉2/𝑚 2 ) = 𝑚2
1 1 1 1

Vol tangki konstan (Rigid) maka V1=V2 maka

𝑃 /𝑚 1,5 𝑚 𝑃 0,6
(𝑃2/𝑚 1 ) = 𝑚2 solve for m2 didapat 𝑚2 = 𝑚1 (𝑃2 )
1 2 1 1

Recall: Mass keluar = Mass awal – Mass akhir

𝑃 0,6 𝑃 0,6
𝑚𝑜𝑢𝑡 = 𝑚1 − 𝑚2 𝑚𝑜𝑢𝑡 = 𝑚1 − 𝑚1 (𝑃2 )  𝑚𝑜𝑢𝑡 = 𝑚1 (1 − (𝑃2 ) ) … … (𝑖𝑖)
1 1

Substitusi (i) ke (ii)

𝑃1 𝑉1 𝑃2 0,6
∴ 𝑚𝑜𝑢𝑡 = (1 − ( ) )
𝑅𝑇1 𝑃1

plug in numbers

(500+100)𝑘𝑃𝑎 5 𝑚3 200+100 0,6


𝑚𝑜𝑢𝑡 = 𝑘𝐽 (1 − (500+100) ) = 1,68 kg
2,0785 (20+273)𝐾
𝐾.𝑘𝑔

2. Tinjau suatu rangkaian piston-cylinder 20 liter berisi gas etana pada kondisi standar (15
o
C, 1 atm). Piston ditekan sambil dipanasi sehingga volume gas menjadi 1 liter dan
temperature 300 oC. Dengan menggunakan generalized correlation tentukan tekanan
gas (atm) pada akhir kompresi+pemanasan tersebut. Properties of ethane: 𝜔 =
1,0 𝑇𝑐 = 305,3 𝐾 𝑃𝑐 = 48 𝑎𝑡𝑚 𝑉𝑐 = 145,5 𝑐𝑚3 /𝑚𝑜𝑙

20 liter, std cond

1 liter 300oC Find P2 = …

Solusi:
𝑃 𝑉𝑡 1𝑎𝑡𝑚(20)𝑙𝑖𝑡𝑒𝑟
Find mol gas: 𝑛 = = 𝑎𝑡𝑚.𝑙𝑖𝑡𝑒𝑟 = 0,8462 𝑚𝑜𝑙
𝑅𝑇 0,08206 (273+15)𝐾
𝑚𝑜𝑙.𝐾

Pada state 2 Vt= 1 liter  volume molar, V2= 1/0,8462=1,1817 liter/mol

Cek korelasi yang digunakan


𝑎𝑡𝑚.𝑙𝑖𝑡𝑒𝑟
𝑍2 𝑅 𝑇2 (1)(0,08206) (300+273𝐾)
𝑃2 = (Asumsi gas ideal)  𝑃2 = 𝑚𝑜𝑙.𝐾
= 39,8 𝑎𝑡𝑚
𝑉2 1,1817𝑙𝑖𝑡𝑒𝑟/𝑚𝑜𝑙

𝑃 39,8
𝑃𝑟2 = 𝑃2 = = 0,8  Pr < 1 Korelasi Generalized virial
𝑐 48

𝑍2 𝑅 𝑇2
𝑃2 =
𝑉2
𝑃
Recall: 𝑍2 = 1 + (𝐵 0 + 𝜔𝐵′ )2 𝑇𝑟2
𝑟2
𝑃2 𝑇
Substitute: 𝑃𝑟2 = 𝑃 and𝑇𝑟2 = 𝑇2
𝑐 𝑐
𝑃2
⁄𝑃
(1+(𝐵0 +𝜔𝐵′ )2 𝑇 𝑐 ) 𝑅 𝑇2
2⁄
𝑇𝑐
𝑃2 = 𝑉1
Rearrange
𝑅 𝑇2
∴ 𝑃2 =
𝑇
𝑉1 − (𝐵0 + 𝜔𝐵′ )2 𝑅 𝑐⁄𝑃
𝑐
Kondisi 2 T2= 300oC
𝑇 300+273
𝑇𝑟2 = 𝑇2 = = 1,877
𝑐 305,3
0,422 0,422
𝐵 0 = 0,083 − 1,6 = 0,083 − 1,8771,6 = −0,0711
𝑇𝑟
′ 0,172 0,172
𝐵 = 0,139 − 4,2 = 0,139 − 1,8774,2 = 0,1268
𝑇𝑟
𝑅 𝑇2
Recall 𝑃2 = 𝑇
𝑉1 −(𝐵 +𝜔𝐵′ )2 𝑅 𝑐⁄𝑃
0
𝑐
Plug in numbers:
(0,08206) (300+273)
𝑃2 = = 40,8 𝑎𝑡𝑚
1,1817−((−0,0711+(1,0)(0,1268)) (0,08206)305,3⁄48)

3. Tinjau pembakaran metana dengan udara berlebih 20% pada suatu combustion
chamber. Panas yang dihasilkan digunakan untuk produksi steam yang selanjutnya
digunakan sebagai input energy suatu heat engine. Air untuk produksi steam terlebih
dahulu dilewatkan suatu preheater memanfaatkan gas buang keluar combustion
chamber. Input air masuk preheater 60 oC (Saturated liquid) dan keluar chamber pada
200 oC (saturated Vapor). Temperatur heat sink dari heat engine 20 oC. (a) Tentukan
minimum flow rate metana (mol/detik) untuk menghasilkan power heat engine 5 MW.
(b) Tentukan thermal efficiency keseluruhan system. (c) Dengan sedikit modifikasi
system akan dapat beroperasi dengan output 5MW tapi dengan flow rate metana yang
lebih rendah dibandingkan (a). Usulkan modifikasi tersebut dan jelaskan mengapa
modifikasi usulan anda akan dapat menurunkan flow rate metana. Note: Kondisi
operasi heat engine tidak dimodifikasi, tetap sama seperti pada (a).
Solusi:

Metana =??
1 bar, 25oC

Udara berlebih 20%


1 bar, 25oC

Saturated water 60oC


Saturated vapor
200oC

QH

5 MW

Water 20oC

Agar CH4 minimum, heat engine must be Carnot engine dan kalor pembakaran yang
dibawa flue gas keluar sistem must be minimum maka T flue gas must be minimum 
batasan T paling rendah adalah = T water masuk preheater ( Recall 2nd law: pemanasan
dari T tinggi ke rendah) Maka T flue gas = 60oC
Tinjau heat engine
(20+273)
Carnot: 𝑒𝑓𝑓 = 1 − (200+273) = 0,38
𝑊 5𝑀𝑊
Q input engine 𝑄𝐻̇ = 𝑒𝑓𝑓 = 0,38 = 13.138.889 𝐽/𝑠
𝑄̇
Mass rate steam, didapat dari 𝑄𝐻̇ = 𝑚.̇ ∆𝐻 𝑣 𝑚̇ = ∆𝐻𝐻𝑣
𝑄̇ 13138,889 𝑘𝐽/𝑠
𝑚̇ = ∆𝐻𝐻𝑣 = 1938,6𝑘𝐽/𝑘𝑔(𝑆𝑡𝑒𝑎𝑚 𝑡𝑎𝑏𝑙𝑒 𝑎𝑡 200𝑜 𝐶) = 6,777𝑘𝑔/𝑠
Tinjau Energy balance boiler
Kalor dari pembakaran digunakan untuk memanaskan air dan combustion product (flue
gas)
𝑜
𝑛̇ (Δ𝐻298 + Δ𝐻𝑝𝑜 ) + 𝑄̇𝑤𝑎𝑡𝑒𝑟 = 0 … … (𝑖)
𝑄̇𝑊𝑎𝑡𝑒𝑟 = 𝑚̇ ∆𝐻 = 𝑚̇ (𝐻200 − 𝐻60 ) = 6,777𝑥(2790,9 − 251,1)
𝑘𝐽
𝑄̇𝑊𝑎𝑡𝑒𝑟 = 17213,53 𝑠 … … (𝑖𝑖)
Reaksi: CH4 + 2O2 CO2 + 2H2O
𝑜 𝑘𝐽
∆𝐻𝑐𝑜𝑚𝑏𝑢𝑠𝑡𝑖𝑜𝑛 = ∆𝐻298 = −802,625 𝑘𝑔 (𝐷𝑎𝑡𝑎 𝑓𝑟𝑜𝑚 𝑇𝑎𝑏𝑙𝑒 𝐶. 4) … … (𝑖𝑖𝑖)

Perhitungan ΔHp
Reaktan:
CH4 = 1 mol; O2 stoikiometrik =2 mol; Total O2 masuk 2x120%= 2,4 mol;
N2 dalam udara = 79/21 x 2,4 = 9,0286 mol
Produk:
CO2 = 1mol; H2O = 2 mol; excess air = O2 masuk - O2 stoikiometrik = 2,4 -2= 0,4 mol;
Inert N2 dalam udara = 9,0286 mol
Recall: ΔHp = <Cpo> (T-To)
〈𝐶𝑝𝑜 〉 ∑ 𝑛𝑖 𝐵𝑖 ∑ 𝑛𝑖 𝐶𝑖 2 2 ∑ 𝑛𝑖 𝐷𝑖
= [∑ 𝑛𝑖 𝐴𝑖 + (𝜏 + 1) + 𝑇𝑜 (𝜏 + 𝜏 + 1) + ]
𝑅 2 3 𝜏 𝑇𝑜 2

Produk Mol A B C D
H2O 2 3,47 0,00145 … 12.100
CO2 1 5,457 0,001045 … -115.700
O2 0,4 3,639 0,000506 … -22.700
N2 9,0286 3,28 0,000593 … 4000

∑ 𝑛𝑖 𝐴𝑖 = (2𝑥 3,47 + 5,457 + 0,4𝑥 3,639 + 9,0286𝑥 3,28) = 43,47


Similarly: ∑ 𝑛𝑖 𝐵𝑖 = 0,009502 ; ∑ 𝑛𝑖 𝐶𝑖 = 0 ; ∑ 𝑛𝑖 𝐷𝑖 = −64465
𝑇 60+273
𝜏 = 𝑇 = 25+273 = 1,117
𝑜
〈𝐶𝑝𝑜 〉 ∑ 𝑛𝑖 𝐵𝑖 ∑ 𝑛𝑖 𝐶𝑖 ∑ 𝑛𝑖 𝐷𝑖
Maka, = [∑ 𝑛𝑖 𝐴𝑖 + 𝑇𝑜 (𝜏 + 1) + 𝑇𝑜 2 (𝜏 2 + 𝜏 + 1) + ]
𝑅 2 3 𝜏 𝑇𝑜 2
〈𝐶𝑝𝑜 〉 0,009502 −64465
= 43,47 + (25 + 273)(1,117 + 1) + 0 + 1,117𝑥(25+273)2 = 45,82
𝑅 2
〈𝐶𝑝𝑜 〉 = 45,82𝑥 𝑅 = 45,82 𝑥 8,314 = 380,92
J
Δ𝐻𝑝𝑜 = 〈𝐶𝑝𝑜 〉(T − 𝑇𝑜 ) = 380,92x(60 − 25) = 13332,2 mol
𝑘𝐽
Δ𝐻𝑝𝑜 = 13,33 … … (𝑖𝑣)
𝑚𝑜𝑙
Substitusi (ii) (iii) (iv) ke (i)
𝑜
𝑛̇ (Δ𝐻298 + Δ𝐻𝑝𝑜 ) + 𝑄̇𝑤𝑎𝑡𝑒𝑟 = 0
𝑛̇ (−802,625 + 13,33) + 17213,53 = 0
−17213,53
𝑛̇ = = 21,8 𝑚𝑜𝑙/𝑠
−789,295
(b) Efisiensi thermal = Woutput/QBoiler
5000000
𝜂= = 29,05%
17213,53
(c) Untuk mengurangi rate Methana hal yang dapat dilakukan yaitu mengurangi kalor
yang dibutuhkan untuk menaikkan suhu air (Qwater) dengan cara menaikkan suhu air
yang masuk preheater karena dari perhitungan sebelumnya rate methane bergantung
pada Qwater, Entalpi perubahan suhu flue gas dan Entalpi pembakaran Methana. Dan
dapat dilihat jika Qwater diturunkan maka Rate Methana akan menngecil (Berbanding
lurus)

4. Gas panas dari suatu cerobong dimanfaatkan sebagai sumber energy untuk produksi
steam, dari saturated liquid 100 oC menjadi saturated vapor 100 oC. Pemanfaatan
energy tersebut mengakibatkan temperature gas cerobong turun dari 1100 oC menjadi
150 oC. Heat capacity gas cerobong: Cp = R(3,83 + 0,000551 T), dimana T dalam K.
Dengan menggunakan temperature lingkungan 25 oC sebagai referensi, tentukan (a)
besarnya lost work proses tersebut dalam kJ/mol gas panas? (b) besarnya maksimum
work yang dapat diperoleh jika steam mengalami kondensasi menjadi saturated liquid
(dalam kJ/mol gas panas). Diketahui kalor latent penguapan air = 2257 kJ/kg.

Solusi:

Flue Gas
150oC
Flue Gas
1100oC
Steamr 100oC Water
Water 100oC 100oC
Condenser

𝑘𝐽
̇ 𝑇𝜎 (
(a) 𝑊𝑙𝑜𝑠𝑡 = 𝑆𝐺 )
Wideal =?
𝑚𝑜𝑙 𝑓𝑙𝑢𝑒 𝑔𝑎𝑠
𝑆̇𝐺
Perlu karena unit Wlost yang diminta per mol flue gas
𝑛̇ 𝑔𝑎𝑠
Entropy generation in boiler:
̇ = 𝑚̇ 𝑠𝑡𝑒𝑎𝑚 Δ𝑆𝑠𝑡𝑒𝑎𝑚 + 𝑛̇ 𝑔𝑎𝑠 Δ𝑆𝑔𝑎𝑠
Recall 𝑆𝐺
𝑆̇𝐺 𝑚̇ 𝑠𝑡𝑒𝑎𝑚
= Δ𝑆𝑠𝑡𝑒𝑎𝑚 + Δ𝑆𝑔𝑎𝑠 per mol gas
𝑛̇ 𝑔𝑎𝑠 𝑛̇ 𝑔𝑎𝑠
Δ𝐻 𝑉 2257 𝑘𝐽
Δ𝑆𝑠𝑡𝑒𝑎𝑚 = = = 6,048 ⁄𝐾. 𝑘𝑔
𝑇𝑠𝑡𝑒𝑎𝑚 (100+273,15) 𝑠𝑡𝑒𝑎𝑚
𝑇2 𝐶𝑝 𝑑𝑇 𝑃
Δ𝑆𝑔𝑎𝑠 = ∫𝑇1 𝑇 − 𝑅 ln 𝑃2 per mol gas
1
𝑇2 𝐶𝑝 𝑑𝑇
Since P2=P1  ∆𝑆𝑔𝑎𝑠 = ∫𝑇1
𝑇
𝑇2 3,83+0,000551𝑇
∆𝑆𝑔𝑎𝑠 = 𝑅 ∫𝑇1 ( ) 𝑑𝑇
𝑇
(150+273,15) (150+273,15) 𝐽
∆𝑆𝑔𝑎𝑠 = 𝑅 [3,83 ln (1100+273,15) + 0,000551 𝑇|(1100+273,15) ] = −41,835 𝐾.𝑚𝑜𝑙𝑔𝑎𝑠
𝑚̇𝑠𝑡𝑒𝑎𝑚
Energy balance untuk dapatkan 𝑛̇ 𝑔𝑎𝑠
𝑇2
Energy dilepas gas = energy diterima steam  𝑛̇ 𝑔𝑎𝑠 ∫𝑇1 𝐶𝑝 𝑑𝑇 +
𝑚̇𝑠𝑡𝑒𝑎𝑚 Δ𝐻 𝑉 = 0
𝑇2
𝑚̇𝑠𝑡𝑒𝑎𝑚 − ∫𝑇1 𝐶𝑝 𝑑𝑇
∴ =
𝑛̇ 𝑔𝑎𝑠 Δ𝐻 𝑉
Dari data: Cp/R = 3,83 + 0,000551 T
𝐶𝑝 𝑇
∴ ∫ 𝐶𝑝 𝑑𝑇 = 𝑅 ∫ 𝑑𝑇 = 𝑅 ∫𝑇 2(3,83 + 0,000551 T) dT
𝑅 1
423,15
0,000551 𝑇 2
∫ 𝐶𝑝 𝑑𝑇 = 𝑅 [3,83 𝑇 |(423,15)
(1373,15) + | ] = −34159,2 𝐽/𝑚𝑜𝑙𝑔𝑎𝑠
2 1373,15
J
Dari data: Δ𝐻 𝑉 = 2257 gram 𝑠𝑡𝑒𝑎𝑚
𝑇2
𝑚̇𝑠𝑡𝑒𝑎𝑚 − ∫𝑇1 𝐶𝑝 𝑑𝑇 −(−34159,2) 𝑔𝑟𝑎𝑚 𝑠𝑡𝑒𝑎𝑚
∴ = = = 15,135
𝑛̇ 𝑔𝑎𝑠 Δ𝐻 𝑉 2257 𝑚𝑜𝑙 𝑔𝑎𝑠
𝑆̇𝐺 𝑚̇ 𝑠𝑡𝑒𝑎𝑚
Recall: = Δ𝑆𝑠𝑡𝑒𝑎𝑚 + Δ𝑆𝑔𝑎𝑠
𝑛̇ 𝑔𝑎𝑠 𝑛̇ 𝑔𝑎𝑠
𝑆̇𝐺
𝑛̇ 𝑔𝑎𝑠
= 15,135 𝑥 6,048 − 41,835 = 49,7 𝐾.𝑚𝑜𝑙𝐽 𝑔𝑎𝑠
𝑆𝐺̇ 𝑘𝐽
𝑊𝑙𝑜𝑠𝑡 = 𝑇𝜎 = 49,7 𝑥 (25 + 273) = 14,8
𝑛̇ 𝑔𝑎𝑠 𝑚𝑜𝑙 𝑔𝑎𝑠

Saturated
Saturated vapor 100oC liquid 100oC

Condenser

Wideal per mol gas =?


𝑘𝐽
Recall: 𝑊𝑖𝑑𝑒𝑎𝑙 = ∆𝐻𝑠𝑡𝑒𝑎𝑚 − 𝑇𝜎 ∆𝑆𝑠𝑡𝑒𝑎𝑚 ( )
𝑘𝑔 𝑠𝑡𝑒𝑎𝑚
𝑘𝐽
∆𝐻𝑠𝑡𝑒𝑎𝑚 = −Δ𝐻𝑉 = −2257
𝑘𝑔 𝑠𝑡𝑒𝑎𝑚
−Δ𝐻𝑉 −2257 𝑘𝐽
∆𝑆𝑠𝑡𝑒𝑎𝑚 = = = −6,048
𝑇𝑠𝑡𝑒𝑎𝑚 (100+273) 𝐾.𝑘𝑔 𝑠𝑡𝑒𝑎𝑚
𝑊𝑖𝑑𝑒𝑎𝑙 = ∆𝐻𝑠𝑡𝑒𝑎𝑚 − 𝑇𝜎 ∆𝑆𝑠𝑡𝑒𝑎𝑚
𝑘𝐽
𝑊𝑖𝑑𝑒𝑎𝑙 = −2257 − (25 + 273,15)(−6,048) = −453,79
𝑘𝑔 𝑠𝑡𝑒𝑎𝑚
Energy balance pada condenser
𝑚̇𝑠𝑡𝑒𝑎𝑚 𝑝𝑟𝑜𝑑𝑢𝑐𝑒𝑑 = 𝑚̇𝑠𝑡𝑒𝑎𝑚 𝑐𝑜𝑛𝑑𝑒𝑛𝑠𝑒𝑑
𝑚̇
Maka 𝑛̇𝑠𝑡𝑒𝑎𝑚 sama dengam kasus a (perhitungan Wlost)
𝑔𝑎𝑠
𝑚̇𝑠𝑡𝑒𝑎𝑚 𝑔𝑟𝑎𝑚 𝑠𝑡𝑒𝑎𝑚
Recall rasio = 15,135
𝑛̇ 𝑔𝑎𝑠 𝑚𝑜𝑙 𝑔𝑎𝑠
15,135 𝑘𝑔 𝑠𝑡𝑒𝑎𝑚 𝑘𝐽
𝑊𝑖𝑑𝑒𝑎𝑙 𝑝𝑒𝑟 𝑚𝑜𝑙 𝑔𝑎𝑠 = ( ) 𝑥 (−453,79 )
1000 𝑚𝑜𝑙 𝑔𝑎𝑠 𝑘𝑔 𝑠𝑡𝑒𝑎𝑚
𝑘𝐽
𝑊𝑖𝑑𝑒𝑎𝑙 𝑝𝑒𝑟 𝑚𝑜𝑙 𝑔𝑎𝑠 = −6,86
𝑚𝑜𝑙 𝑔𝑎𝑠
TK 3081-Termodika Dasar A
Perbaikan I Modul I 2013/2014

1. Suatu Heat Engine digunakan untuk menghasilkan kerja dengan kalor pada Heat sink
2000 kJ/s dan temperature 5oC. Hitunglah kerja maksimum yang dapat dihasilkan
mesin jika temperature tinggi mesin 25oC
2. Suatu tangki silinder berisi gas bertekanan 10 bar pada 325 K, Dengan persamaan
Redlich/Kwong tentukan volume gas (cm3/mol) yang menempati tangki (Diketahui
sifat gas Pc = 40 bar Tc = 418 K)
3. Tinjau sebuah turbin uap. Energi yang dihasilkan digunakan untuk menggerakan
pompa dan generator listrik. Pompa dan turbin beroperasi pada tekanan 100 kPa. Air
yang masuk pompa bersuhu 20oC dengan rate 15 m/s. Luas permukaan pompa dan
turbin berturut-turut 1,3 m2 dan 0,18 m2. Daya yang dihasilkan generator sebesar 2
MWe. Jika entalpi pada suhu 20oC dan 200oC berturut-turut 290 kJ/kg dan 480 kJ/kg.
Tentukan energy yang diperlukan per kg udara. (BM Udara = 29 gr/mol)
P = 100 kPa
T = 20oC P = 100 kPa
H = 290 kJ/kg T = 200oC
v = 15 m/s H = 480 kJ/kg
A = 1,3 m2 A = 0,18 m2

2 Mwe

Gen

4. Tinjau pembakaran Methana dengan udara berlebih pada suatu combustion chamber.
Panas yang dihasilkan digunakan untuk menaikkan suhu air dari 25oC (saturated liquid)
menjadi 200oC (saturated vapor). Udara yang digunakan dipanaskan menggunakan air
preheater dan masuk chamber pada 200oC, 1 bar pada rate 600 kmol/hr. Gas Methana
masuk chamber pada suhu 25oC, 1 bar pada rate 50 kmol/hr. Flue gas yang keluar
bersuhu 300oC. Jika Heat loss dari chamber 5 x 106 kJ/hr, tentukan laju air yang masuk
(kg/hr) dan laju flue gas (MMSCFD) keluar chamber. (Cp Methana = 29 kJ/kmol.K;
ΔH298 Methana= 802625 J/mol)
5. Pada sebuah kasus steady state flow, 1 mol/hr gas A pada 600 K dan 1 atm bercampur
secara terus menerus dengan 2 mol/hr Gas B pada 400 K dan 1 atm. Uap campuran gas
A dam B yang dihasilkan bersuhu 550 K pada 1 atm. Skematik proses dapat dilihat
pada gambar di bawah. Tentukan Temperatur lingkungan minimum pada proses heat
transfer tersebut.Asumsi gas merupakan gas ideal, dan perubahan energy kinetic dan
potensial tidak signifikan (Cp = 7/2 R)

A/B MIx
550 K

Gas A Gas B
1 mol/hr Heating 1 mol/hr
600 k chamber 400 k
SOLUSI
TK 3081-Termodika Dasar A
Perbaikan I Modul I 2013/2014
1. Suatu Heat Engine digunakan untuk menghasilkan kerja dengan kalor pada Heat sink
2000 kJ/s dan temperature 5oC. Hitunglah kerja maksimum yang dapat dihasilkan
mesin jika temperature tinggi mesin 25oC
Solusi:
25oC Warm
Wmax  Carnot engine Water
QH
𝑊 𝑄𝐻 −𝑄𝐶 𝑄𝐻 𝑇𝐻 WMAX=?
= = −1= −1
𝑄𝑐 𝑄𝐶 𝑄𝐶 𝑇𝐶
𝑇
𝑊̇𝑚𝑎𝑥 = 𝑄̇𝐶 ( 𝑇𝐻 − 1)
𝐶 QC =2000kJ/s
25+273
𝑊̇𝑚𝑎𝑥 = 2000 ( 5+273 − 1)
𝑘𝐽 5oC
𝑊̇𝑚𝑎𝑥 = 144 𝑠 = 144 𝑘𝑊
Cold water

2. Suatu tangki silinder berisi gas bertekanan 10 bar pada 325 K, Dengan persamaan
Redlich/Kwong tentukan volume gas (cm3/mol) yang menempati tangki (Diketahui
sifat gas Pc = 40 bar Tc = 418 K)
Solusi:
𝑍𝑅𝑇
Recall: 𝑉 = , Z dihitung dari hasil iterasi
𝑃
𝑖 𝑍 −𝛽
Iteration scheme for gas 𝑍𝑖+1 = 1 + 𝛽 − 𝑞𝛽 [(𝑍 +𝜖𝛽)(𝑍 ] … … (𝑖)
+𝜎𝛽) 𝑖 𝑖
𝑃𝑟 𝛼(𝑇𝑟 )
Where 𝛽 = Ω 𝑇 and 𝑞 = 𝜓
𝑟 Ω𝑇𝑟
For RK: ϵ = 0 ; σ = 1 ; α(Tr)= Tr -1/2
; Ω=0,08664 ; Ψ=0,42748 (see table)
𝑇 325 𝑃 10
𝑇𝑟 = 𝑇 = 418 = 0,7775 ; 𝑃𝑟 = 𝑃 = 40 = 0,25
𝑐 𝐶
𝑃𝑟 0,25
𝛽 = Ω 𝑇 = 0,08664 0,7775 = 0,02786 … … (ii)
𝑟
1

𝛼(𝑇𝑟 ) 𝑇𝑟 −1/2 0,7775 2
𝑞=𝜓 =𝜓 = 0,42748 0,08664𝑥0,7775 = 7,1969 … … (𝑖𝑖𝑖)
Ω𝑇𝑟 Ω𝑇𝑟
Substitusi (ii) dan (iii) ke (i) dan lakukan iterasi
Start with Z=1
𝑍𝑖−0,02786
𝑍1 = 1 + 0,02786 − (7,1969)(0,02786) [ ] = 0,8382
(𝑍 +(0)0,02786)(𝑍 +(1)0,02786)
𝑖 𝑖
Z2= 0,8041 Z3=0,7952…… Z= 0,7919
𝑐𝑚3 𝑏𝑎𝑟
𝑍 𝑅 𝑇 0,7919𝑥83,14 𝑚𝑜𝑙 𝐾 𝑥325 𝐾 𝑐𝑚3
∴𝑉= = = 2140
𝑃 10 𝑏𝑎𝑟 𝑚𝑜𝑙
Cara lain
𝑅𝑇 𝑎(𝑇) 𝑉𝑖 −𝑏
Iteration scheme for gas 𝑉𝑖+1 = +𝑏− … … (𝑖)
𝑃 𝑃 (𝑉𝑖 +𝜖𝑏)(𝑉𝑖 +𝜎𝑏)
𝑅𝑇𝑐 𝛼(𝑇𝑟 )𝑅 2 𝑇𝐶 2
Where 𝑏 = Ω and 𝑎(𝑇) = 𝜓
𝑃𝑐 𝑃𝑐
For RK: ϵ = 0 ; σ = 1; α(Tr)= Tr -1/2
; Ω=0,08664 ; Ψ=0,42748 (see table)
𝑇 325
𝑇𝑟 = 𝑇 = 418 = 0,7775
𝑐
Plug in numbers
𝑅𝑇𝑐 83,14x418
𝑏=Ω = 0,08664 x = 75,27 … … (𝑖𝑖)
𝑃𝑐 40
1

𝛼(𝑇𝑟 )𝑅 2 𝑇𝐶 2 0,7775 2 𝑥83,142 𝑥4182
𝑎(𝑇) = 𝜓 = 0,42748 = 14637881 … … (𝑖𝑖𝑖)
𝑃𝑐 40
Substitusi (ii) dan (iii) ke (i) dan lakukan iterasi
Start with V=RT/P= 83,14 x 325/10 =2702 cm3/mol
83,14𝑥325 14637881 2702−75,27
𝑉1 = + 75,27 − (2702)(2702+75,27)
= 2264,9
10 10
V2= 2172,6 V3=2148,6…… V= 2140 cm3/mol
𝑐𝑚3
∴ 𝑉 = 2140
𝑚𝑜𝑙

3. Tinjau sebuah turbin uap. Energi yang dihasilkan digunakan untuk menggerakan
pompa dan generator listrik. Pompa dan turbin beroperasi pada tekanan 100 kPa. Air
yang masuk pompa bersuhu 20oC dengan rate 15 m/s. Luas permukaan pompa dan
turbin berturut-turut 1,3 m2 dan 0,18 m2. Daya yang dihasilkan generator sebesar 2
MWe. Jika entalpi pada suhu 20oC dan 200oC berturut-turut 290 kJ/kg dan 480 kJ/kg.
Tentukan energy yang diperlukan per kg udara. (BM Udara = 29 gr/mol)
P = 100 kPa
T = 20oC P = 100 kPa
H = 290 kJ/kg T = 200oC
v = 15 m/s H = 480 kJ/kg
A = 1,3 m2 A = 0,18 m2

2 Mwe

Gen

q Sistem
yangditinjau

Solusi:
Neraca energy per kg udara:
𝑣2 2 −𝑣1 2
𝐻2 − 𝐻1 + + ∆𝐸𝑝𝑜𝑡 = 𝑞 + 𝑤
2
Pemanasan per kg udara:
𝑣2 2 − 𝑣1 2
𝑞 = −𝑤 + 𝐻2 − 𝐻1 + … … (𝑖)
2
𝑊
Work per unit mass: 𝑤 = 𝑚̇
Perhitungan ṁ
𝑃 100
𝜌1 = 𝑅 𝑇1 𝐵𝑀 = 8,314𝑥 (20+273) 29 = 1,19 𝑘𝑔/𝑚3
1
𝑃 100
𝜌2 = 𝑅 𝑇2 𝐵𝑀 = 8,314𝑥 (200+273) 29 = 0,737 𝑘𝑔/𝑚3
2
𝑚̇ = 𝐴1 𝑣1 𝜌1 = 1,3 (15)1,19 = 23,2 𝑘𝑔/𝑠
𝑊 −2000 𝑘𝐽
Plug in numbers 𝑤 = = = −86,2 … … (𝑖𝑖) (Tanda minus karena sistem
𝑚̇ 23,2 𝑘𝑔
menghasilkan kerja)
𝑚̇ 23,2 𝑚
𝑣2 = 𝐴 = 0,18𝑥0,737 = 174,9 … … (𝑖𝑖𝑖)
2 𝜌2 𝑠
Substitusi (ii) dan (iii) ke (i)
𝑘𝐽 𝑘𝐽 174,92 −152 𝐽 𝑘𝐽 𝑘𝐽
𝑞 = −(−86,2) 𝑘𝑔 + (480 − 290) 𝑘𝑔 + = 291 𝑘𝑔
2 𝑘𝑔 1000 𝐽
4. Tinjau pembakaran Methana dengan udara berlebih pada suatu combustion chamber.
Panas yang dihasilkan digunakan untuk menaikkan suhu air dari 25oC (saturated liquid)
menjadi 200oC (saturated vapor). Udara yang digunakan dipanaskan menggunakan air
preheater dan masuk chamber pada 200oC, 1 bar pada rate 600 kmol/hr. Gas Methana
masuk chamber pada suhu 25oC, 1 bar pada rate 50 kmol/hr. Flue gas yang keluar
bersuhu 300oC. Jika Heat loss dari chamber 5 x 106 kJ/hr, tentukan laju air yang masuk
(kg/hr) dan laju flue gas (MMSCFD) keluar chamber.(Cp Methana = 29 kJ/kmol.K;
ΔH298 Methana= 802625 J/mol)
Solusi:
Problem
Qloss = 5 E6 kJ/hr
CH4 50 kmol/hr
1 bar, 25oC Flue Gas
300oC
Udara 600 kmol/hr
Air preheater
1 bar, 200oC

Steam Water 25oC


200oC
Strategi penyelesaian soal

Qloss = 5 E6 kJ/hr
CH4 50 kmol/hr
1 bar, 25oC Flue Gas
200oC 300oC
Udara 600 kmol/hr
Preheater
1 bar, 200oC
Qpreheater Steam Water 25oC
Cooler
200oC

Basis perhitungan enthalpy of combustion adalah 25oC. Untuk meperhitungkan efek


preheater, seolah-olah udara panas didinginkan dahulu menjadi 25oC dengan cooler
sebelum combustion dan energy yang tersimpan pada pendinginan tersebut
dimunculkan kembali bersama dengan hasil combustion.
Jadi energy balance keseluruhan sistem menjadi:
𝑄𝑐𝑜𝑚𝑏𝑢𝑠𝑡𝑖𝑜𝑛 + 𝑄𝑝𝑟𝑒ℎ𝑒𝑠𝑡𝑒𝑟 + 𝑄𝑤𝑎𝑡𝑒𝑟 + 𝑄𝑙𝑜𝑠𝑠 + 𝑄𝑓𝑙𝑢𝑒 𝑔𝑎𝑠 = 0
Recall:𝑄̇𝑤𝑎𝑡𝑒𝑟 = 𝑚̇𝑤𝑎𝑡𝑒𝑟 𝑥 ∆𝐻𝑤𝑎𝑡𝑒𝑟 
−(𝑄𝑐𝑜𝑚𝑏𝑢𝑠𝑡𝑖𝑜𝑛 + 𝑄𝑝𝑟𝑒ℎ𝑒𝑠𝑡𝑒𝑟 + 𝑄𝑙𝑜𝑠𝑠 + 𝑄𝑓𝑙𝑢𝑒 𝑔𝑎𝑠 )
𝑚̇𝑤𝑎𝑡𝑒𝑟 = … … (𝑖)
∆𝐻𝑤𝑎𝑡𝑒𝑟
Basis perhitungan 1 jam:
𝑘𝑚𝑜𝑙 𝑘𝐽 𝑘𝐽
𝑄̇𝑝𝑟𝑒ℎ𝑒𝑠𝑡𝑒𝑟 = 𝑛̇ 𝐶𝑝. ∆𝑇 = 600 29 (25 − 200)𝐾 = −3045000 … … (𝑖𝑖)
ℎ𝑟 𝑘𝑚𝑜𝑙.𝐾 ℎ𝑟
𝑘𝑚𝑜𝑙 𝑘𝐽 𝑘𝐽
𝑄̇𝑐𝑜𝑚𝑏𝑢𝑠𝑡𝑖𝑜𝑛 = 𝑛̇ ∆H298
𝑜
= 50 ℎ𝑟 𝑥 − 802625 𝑘𝑚𝑜𝑙 = 40131250 ℎ𝑟 … … (𝑖𝑖𝑖)
𝑄̇𝑓𝑙𝑢𝑒 𝑔𝑎𝑠 = 𝑛̇ < 𝐶𝑝 >. ∆𝑇  Perlu <Cp>
〈𝐶𝑝𝑜 〉 ∑ 𝑛𝑖 𝐵𝑖 ∑ 𝑛𝑖 𝐶𝑖 ∑ 𝑛𝑖 𝐷𝑖
Recall: = [∑ 𝑛𝑖 𝐴𝑖 + 𝑇𝑜 (𝜏 + 1) + 𝑇𝑜 2 (𝜏 2 + 𝜏 + 1) + ]
𝑅 2 3 𝜏 𝑇𝑜 2

Persamaan reaksi CH4 + 2O2 CO2 + 2H2O


Reaktan:
CH4 = 50 kmol; O2 stoikiometrik =2x50= 100 kmol; Total O2 masuk = 21% x 600
kmol =126 kmol; N2 dalam udara = 79% x600 kmol = 474 kmol (Remember Air
consist of 79% N2 and 21% O2)
Produk:
CO2 = 50 kmol; H2O = 2x50= 100 kmol; excess air = O2 masuk - O2 stoikiometrik =
126-100 =26 kmol; Inert N2 dalam udara = 474 kmol
Recall: ΔHp = <Cpo> (T-To)
Produk Mol A B C D
H2O 100 3,47 0,00145 … 12.100
CO2 50 5,457 0,001045 … -115.700
O2 26 3,639 0,000506 … -22.700
N2 474 3,28 0,000593 … 4000
∑ 𝑛𝑖 𝐴𝑖 = (100𝑥 3,47 + 50𝑥5,457 + 26𝑥 3,639 + 474𝑥3,28) = 2269,2
Similarly: ∑ 𝑛𝑖 𝐵𝑖 = 0,4915 ; ∑ 𝑛𝑖 𝐶𝑖 = 0 ; ∑ 𝑛𝑖 𝐷𝑖 = −3269200
𝑇 300+273
𝜏 = 𝑇 = 25+273 = 1,923
𝑜
〈𝐶𝑝𝑜 〉 ∑ 𝑛𝑖 𝐵𝑖 ∑ 𝑛𝑖 𝐶𝑖 ∑ 𝑛𝑖 𝐷𝑖
Maka, = [∑ 𝑛𝑖 𝐴𝑖 + 𝑇𝑜 (𝜏 + 1) + 𝑇𝑜 2 (𝜏 2 + 𝜏 + 1) + ]
𝑅 2 3 𝜏 𝑇𝑜 2
〈𝐶𝑝𝑜 〉 0,4915 −3269200
= 2269,2 + (25 + 273)(1,923 + 1) + 0 + 1,923𝑥(25+273)2 = 2464
𝑅 2
𝑛̇ 〈𝐶𝑝𝑜 〉 = 2464𝑥 𝑅 = 2464 𝑥 8,314 = 20486 𝑘𝐽/𝐾
kJ
𝑄̇𝑓𝑙𝑢𝑒 𝑔𝑎𝑠 = 𝑛̇ 〈𝐶𝑝𝑜 〉(T − 𝑇𝑜 ) = 20486x(300 − 25) = 5633650 hr … … (iv)
∆𝐻𝑤𝑎𝑡𝑒𝑟 = 𝐻𝑜𝑢𝑡 − 𝐻𝑖𝑛
𝑘𝐽
𝐻𝑜𝑢𝑡 = 2790,9 𝑘𝑔 (𝑠𝑡𝑒𝑎𝑚 𝑡𝑎𝑏𝑙𝑒 𝑎𝑡 200𝑜 𝐶)

𝑘𝐽
𝐻𝑖𝑛 = 104,8 (𝑠𝑡𝑒𝑎𝑚 𝑡𝑎𝑏𝑙𝑒 𝑎𝑡 25𝑜 𝐶)
𝑘𝑔

𝑘𝐽
∆𝐻𝑤𝑎𝑡𝑒𝑟 = 2790,9 − 104,8 = 2686,1 𝑘𝑔 … … (𝑣)

Substitusi (ii) (iii) (iv) dan (v) ke (i)


−(−40131250+(−3045000)+5𝑥106 +5633650)
𝑚̇𝑤𝑎𝑡𝑒𝑟 = = 12115 𝑘𝑔/ℎ𝑟
2686,1
(b) Flow rate flue gas = flow rate gas masuk = (50+600) kmol/hr

Konversi ke MMSCFD
𝑝𝑠𝑖𝑎𝑓𝑡3
𝑅𝑇 10,73 𝑥 520 𝑅 𝑓𝑡 3
𝑅 𝑙𝑏𝑚𝑜𝑙
𝑉= = = 379,6 (standard condition)
𝑃 14,7 𝑝𝑠𝑖𝑎 𝑙𝑏𝑚𝑜𝑙
𝑘𝑚𝑜𝑙 1000 𝑚𝑜𝑙 𝑙𝑏𝑚𝑜𝑙 𝑓𝑡 3 24 ℎ𝑟 𝑀𝑀𝑆𝐶𝐹
𝑛̇ = 650 𝑥 𝑥 𝑥379,6 𝑥 𝑥 = 13 𝑀𝑀𝑆𝐶𝐹𝐷
ℎ𝑟 𝑘𝑚𝑜𝑙 453,59 𝑚𝑜𝑙 𝑙𝑏𝑚𝑜𝑙 𝑑𝑎𝑦 106 𝑓𝑡 3

5. Pada sebuah kasus steady state flow, 1 mol/hr gas A pada 600 K dan 1 atm bercampur
secara terus menerus dengan 2 mol/hr Gas B pada 400 K dan 1 atm. Uap campuran gas
A dam B yang dihasilkan bersuhu 550 K pada 1 atm. Skematik proses dapat dilihat
pada gambar di bawah. Tentukan Temperatur lingkungan minimum pada proses heat
transfer tersebut.Asumsi gas merupakan gas ideal, dan perubahan energy kinetic dan
potensial tidak signifikan (Cp = 7/2 R)
Solusi:
Recall Entropi balance:
A/B MIx
𝑄̇
∆(𝑆𝑛 )𝑓𝑠 − 𝑇 = 𝑆𝐺̇ 550 K
𝜎

Gas A
Agar proses terjadi ṠG >= 0 Gas B
1 mol/hr
1 mol/hr
Tminimum=?  set ṠG=0 600 k Heating
400 k
chamber
Hitung dulu Q̇ dari energy balance:

𝑄̇ = ∆(𝐻𝑛̇ )𝑓𝑠 = 𝑛̇ 𝑜𝑢𝑡 𝐻𝑜𝑢𝑡 − 𝑛̇ 𝐴 𝐻𝐴 − 𝑛̇ 𝐵 𝐻𝐵

Note that 𝑛̇ 𝑜𝑢𝑡 = 𝑛̇ 𝐴 + 𝑛̇ 𝐵

𝑄̇ = (𝑛̇ 𝐴 + 𝑛̇ 𝐵 )𝐻𝑜𝑢𝑡 − 𝑛̇ 𝐴 𝐻𝐴 − 𝑛̇ 𝐵 𝐻𝐵

Rearrange 𝑄̇ = 𝑛̇ 𝐴 (𝐻𝑜𝑢𝑡 − 𝐻𝐴 ) − 𝑛̇ 𝐵 (𝐻𝑜𝑢𝑡 − 𝐻𝐵 )

𝑄̇ = 𝑛̇ 𝐴 ∆𝐻𝐴 − 𝑛̇ 𝐵 ∆𝐻𝐵 = 𝑛̇ 𝐴 𝐶𝑝∆𝑇𝐴 − 𝑛̇ 𝐵 𝐶𝑝∆𝑇𝐵

𝑄̇ = 𝑛̇ 𝐴 𝐶𝑝(𝑇𝑓 − 𝑇𝐴 ) − 𝑛̇ 𝐵 𝐶𝑝(𝑇𝑓 − 𝑇𝐵 ) dimana Cp = 7/2 R =7/2 x 8,314 =29,099

Plug in values 𝑄̇ = 1𝑥29,099(550 − 600) − 1𝑥29,099(550 − 400) = 2910 𝐽/ℎ𝑟


𝑄̇
Entropi Balance: ∆(𝑆𝑛 )𝑓𝑠 − 𝑇 = 𝑆𝐺̇
𝜎

𝑄̇ 𝑄 ̇
𝑆𝐺̇ = 𝑛̇ 𝑜𝑢𝑡 𝑆𝑜𝑢𝑡 − 𝑛̇ 𝐴 𝑆𝐴 − 𝑛̇ 𝐵 𝑆𝐵 − 𝑇  𝑆𝐺̇ = 𝑛̇ 𝐴 ∆𝑆𝐴 + 𝑛̇ 𝐵 ∆𝑆𝐵 − 𝑇
𝜎 𝜎

𝑄 𝐶𝑝 𝑇
Recall: ∆𝑆 = ∫ 𝑇 = ∫ 𝑑𝑇 = 𝐶𝑝 ln 𝑇2
𝑇 1

𝑇𝑓 𝑇𝑓 𝑄̇
∴ 𝑆𝐺̇ = 𝑛̇ 𝐴 𝐶𝑝 ln + 𝑛̇ 𝐵 𝐶𝑝 ln −
𝑇𝐴 𝑇𝐵 𝑇𝜎
𝑇 𝑇 𝑄̇
Tminimum=?  set ṠG=0 0 = 𝑛̇ 𝐴 𝐶𝑝 ln 𝑇 𝑓 + 𝑛̇ 𝐵 𝐶𝑝 ln 𝑇 𝑓 − 𝑇
𝐴 𝐵 𝜎

Plug in values
550 550 2910
(1)29,099 ln 600 + (1)29,099 ln 400 − =0
𝑇𝜎

Solve for Tσ = 432 K

Read: Introduction to Chemical Engineering Thermodynamics 7th ed (J.M Smith, Van N


ess, Abbott) example 5.5
TK 3081-Termodika Dasar A
Perbaikan II Modul I 2013/2014

1. Tinjau suatu tangki rigid 5 m3 berisi gas A dengan tekanan 500 kPa gage dan
temperature 20 oC. Tekanan atmosfer 100 kPa. Pada suatu saat valve tangki dibuka
sebagian sehingga tekanan gas turun. Tidak ada perpindahan kalor melalui dinding
tangki. Temperature akhir tidak diketahui namun relasi energy internal vs temperature
diketahui yaitu U (Kj/kg) = 3,115 T (K). Kontribusi perubahan energy kinetic dan
potensial dalam neraca energy tidak signifikan. Property gas dalam tangki homogen.
BM gas = 4 gram/mol. Jika kerugian kebocoran gas Rp 5.000.000/kg gas, dengan
pendekatan gas ideal tentukan kerugian yang dialami akibat kebocoran gas pada saat
tekanan tangki telah menjadi 200 kPA gage. Hint: Perlu dihitung mass out dari
tangki.Penurunan energy internal dalam tangki = energy internal keluar tangki oleh
aliran massa sebesar 𝛿𝑚 + flow work oleh mass sebesar 𝛿𝑚, dimana 𝛿𝑚 =
𝑖𝑛𝑓𝑖𝑛𝑖𝑡𝑒𝑠𝑖𝑚𝑎𝑙 𝑚𝑎𝑠𝑠
2. Suatu tangki silinder berisi cairan bertekanan 10 bar pada 325 K, Dengan persamaan
Redlich/Kwong tentukan volume cairan (cm3/mol) yang menempati tangki (Diketahui
sifat cairan Pc = 40 bar Tc = 418 K)
3. Tinjau pembakaran metana dengan udara berlebih 20% pada suatu combustion chamber.
Panas yang dihasilkan digunakan untuk produksi steam yang selanjutnya digunakan
sebagai input energy suatu heat engine. Udara yang masuk chamber dilewatkan air
preheater hingga 200oC, 1 bar dan Gas Methana pada 25oC, 1 bar. Flue gas keluar
chamber pada 300oC. Input air masuk Chamber 20oC (Saturated liquid) dan keluar
chamber pada 200 oC (saturated Vapor). Temperature heat sink adalah 20oC. Jika rate
Methana 10 kmol/hr dan rate udara 120 kmol/hr dan heat loss chamber 106 kJ/hr
Tentukan Power maksimal yang dapat dihasilkan oleh heat engine (kW)?
4. Tinjau air dalam suatu system tertutup menerima kerja sebesar 180 W dan menyerap
kalor sebesar 30 W . Rate Qloss mengikuti persamaan −210[1 − 𝑒 −0,03 𝑡 ]. (a) Tentukan
laju perubahan energy dalam setelah 2 menit! (b) Jika system steady state berapakah
Qloss system?
5. Tinjau proses perpindahan panas. Untuk kasus Isentropic, Tentukan Entropi Generation
system tersebut!

400oC

Q = 1000 J

50oC
SOLUSI
TK 3081-Termodika Dasar A
Perbaikan II Modul I 2013/2014

1. Tinjau suatu tangki rigid 5 m3 berisi gas A dengan tekanan 500 kPa gage dan
temperature 20 oC. Tekanan atmosfer 100 kPa. Pada suatu saat valve tangki dibuka
sebagian sehingga tekanan gas turun. Tidak ada perpindahan kalor melalui dinding
tangki. Temperature akhir tidak diketahui namun relasi energy internal vs temperature
diketahui yaitu U (Kj/kg) = 3,115 T (K). Kontribusi perubahan energy kinetic dan
potensial dalam neraca energy tidak signifikan. Property gas dalam tangki homogen.
BM gas = 4 gram/mol. Jika kerugian kebocoran gas Rp 5.000.000/kg gas, dengan
pendekatan gas ideal tentukan kerugian yang dialami akibat kebocoran gas pada saat
tekanan tangki telah menjadi 200 kPA gage. Hint: Perlu dihitung mass out dari
tangki.Penurunan energy internal dalam tangki = energy internal keluar tangki oleh
aliran massa sebesar 𝛿𝑚 + flow work oleh mass sebesar 𝛿𝑚, dimana 𝛿𝑚 =
𝑖𝑛𝑓𝑖𝑛𝑖𝑡𝑒𝑠𝑖𝑚𝑎𝑙 𝑚𝑎𝑠𝑠
Solusi:

State 1 P atm = 100 kPA State 2


5 m3 U=3,115 T 5 m3
500 kPa gage 200 kPa gage
Mass out=??
20 oC 20 oC

Mass balance: Mass keluar = Mass awal – Mass akhir

Mass awal dihitung dengan gas ideal (P V T diketahui)


𝑃1 𝑉1
𝑚1 = … … (𝑖)
𝑅𝑇1

Mass akhir dihitung dari relasi mass dengan pressure yang diturunkan dari neraca
energy berikut:

𝑑𝑈 = 𝑢𝑑𝑚 + 𝑃𝑣𝑑𝑚 𝑑(𝑚𝑢) = 𝑢𝑑𝑚 + 𝑃𝑣𝑑𝑚

U = internal energy total; u= internal energy per unit mass; Pv=flow work per unit mass

𝑑(𝑚𝑢) = 𝑢𝑑𝑚 + 𝑃𝑣𝑑𝑚  𝑢𝑑𝑚 + 𝑚𝑑𝑢 = 𝑢𝑑𝑚 + 𝑃𝑣𝑑𝑚 𝑚𝑑𝑢 = 𝑃𝑣𝑑𝑚

u= 3,115T  du=3,115 𝑚 3,115𝑑𝑇 = 𝑃𝑣𝑑𝑚


𝑃𝑣 𝑑(𝑃𝑣) 𝑑(𝑃𝑣) 3,115 𝑑(𝑃𝑣) 𝑑𝑚
Gas Ideal 𝑇 =  𝑑𝑇 = 𝑅
𝑚 3,115 𝑅
= 𝑃𝑣𝑑𝑚 ∴ 𝑅 𝑃𝑣
= 𝑚
𝑅

v adalah specific volume, vol per unit mass. Karena persamaan berbasis massa maka
R harus dinyatakan dalam massa:
𝑘𝐽 𝑘𝐽 𝑘𝐽
𝑅 = 8,314 𝑘𝑚𝑜𝑙.𝐾 BM=4  𝑅 = 8,314 𝑘𝑔 = 2,0785 𝑘𝑔.𝐾
𝑘𝑚𝑜𝑙 𝑥4 .𝐾
𝑘𝑚𝑜𝑙

3,115 3,115 3,115 𝑑(𝑃𝑣) 𝑑𝑚 𝑑(𝑃𝑣) 𝑑𝑚


Maka, = 2,0785 = 1,5  =  1,5 =
𝑅 𝑅 𝑃𝑣 𝑚 𝑃𝑣 𝑚

𝑃2 𝑣2 𝑚 𝑃 𝑣 1,5 𝑚
Integrasi kedua ruas 1,5 ln = ln 𝑚2 (𝑃2 𝑣2 ) = 𝑚2
𝑃1 𝑣1 1 1 1 1

𝑃2 𝑉2 /𝑚2 1,5 𝑚2
v= Vol/mass  ( ) =
𝑃1 𝑉1 /𝑚1 𝑚1

Vol tangki konstan (Rigid) maka V1=V2 maka

𝑃 /𝑚 1,5 𝑚 𝑃 0,6
(𝑃2/𝑚 1 ) = 𝑚2 solve for m2 didapat 𝑚2 = 𝑚1 (𝑃2 )
1 2 1 1

Recall: Mass keluar = Mass awal – Mass akhir

𝑃 0,6 𝑃 0,6
𝑚𝑜𝑢𝑡 = 𝑚1 − 𝑚2 𝑚𝑜𝑢𝑡 = 𝑚1 − 𝑚1 (𝑃2 )  𝑚𝑜𝑢𝑡 = 𝑚1 (1 − (𝑃2 ) ) … … (𝑖𝑖)
1 1

Substitusi (i) ke (ii)

𝑃1 𝑉1 𝑃2 0,6
∴ 𝑚𝑜𝑢𝑡 = (1 − ( ) )
𝑅𝑇1 𝑃1

plug in numbers

(500+100)𝑘𝑃𝑎 5 𝑚3 200+100 0,6


𝑚𝑜𝑢𝑡 = 𝑘𝐽 (1 − (500+100) ) = 1,68 kg
2,0785 (20+273)𝐾
𝐾.𝑘𝑔

Kerugian: mout x harga gas = 1,68 kg x 5000000 Rupiah/kg = 8.400.000 Rupiah

2. Suatu tangki silinder berisi cairan bertekanan 10 bar pada 325 K, Dengan persamaan
Redlich/Kwong tentukan volume cairan (cm3/mol) yang menempati tangki (Diketahui
sifat cairan Pc = 40 bar Tc = 418 K)
Solusi
350 K; 2 bar (all vapor)
Find
350 K; 9,4573 bar (vapor/liquid) Vmolar=
𝑍𝑅𝑇
Recall: 𝑉 = , Z dihitung dari hasil iterasi
𝑃
1+𝛽−𝑍𝑖
Iteration scheme for liquid 𝑍𝑖+1 = 𝛽 + [(𝑍𝑖 + 𝜖𝛽)(𝑍𝑖 + 𝜎𝛽) ] … … (𝑖)
𝑞𝛽
𝑃 𝛼(𝑇𝑟 )
Where 𝛽 = Ω 𝑇𝑟 and 𝑞 = 𝜓
𝑟 Ω𝑇𝑟
For RK: ϵ = 0 ; σ = 1 ; α(Tr)= Tr-1/2 ; Ω=0,08664 ; Ψ=0,42748
𝑇 325 𝑃 10
𝑇𝑟 = 𝑇 = 418 = 0,7775 ; 𝑃𝑟 = 𝑃 = 40 = 0,25
𝑐 𝐶
𝑃𝑟 0,25
𝛽 = Ω 𝑇 = 0,08664 0,7775 = 0,02786 … … (ii)
𝑟
1

𝛼(𝑇𝑟 ) 𝑇𝑟 −1/2 0,7775 2
𝑞=𝜓 =𝜓 = 0,42748 0,08664𝑥0,7775 = 7,197 … … (𝑖𝑖𝑖)
Ω𝑇𝑟 Ω𝑇𝑟
Substitusi (ii) dan (iii) ke (i) dan lakukan iterasi
Start with Z=β
1+0,02786−0,02786
𝑍1 = 0,02786 + [(0,02786 + 0𝑥0,02786)(0,02786 + 1𝑥0,02786) ] = 0,0356
7,197𝑥0,02786
Z2= 0,039 Z3=0,0407…… Z= 0,0426
𝑐𝑚3 𝑏𝑎𝑟
𝑍𝑅𝑇 0,0426𝑥83,14 𝑥325 𝐾 𝑐𝑚3
Maka 𝑉 = = 𝑚𝑜𝑙 𝐾
= 115,1 𝑚𝑜𝑙
𝑃 10𝑏𝑎𝑟

3. Tinjau pembakaran metana dengan udara berlebih pada suatu combustion chamber.
Panas yang dihasilkan digunakan untuk produksi steam yang selanjutnya digunakan
sebagai input energy suatu heat engine. Udara yang masuk chamber dilewatkan air
preheater hingga 200oC, 1 bar dan Gas Methana pada 25oC, 1 bar. Flue gas keluar
chamber pada 300oC. Input air masuk Chamber 20oC (Saturated liquid) dan keluar
chamber pada 200 oC (saturated Vapor). Temperature heat sink adalah 20oC. Jika rate
Methana 10 kmol/hr dan rate udara 120 kmol/hr dan heat loss chamber 106 kJ/hr
Tentukan Power maksimal yang dapat dihasilkan oleh heat engine (kW)?
Solusi Qloss = 1 E6 kJ/hr
Metana = 10 kmol/hr
1 bar, 25oC
Udara=12
Preheater Flue Gas 300oC
kmol/hr
1 bar, 200oC Water 20oC
Steam 200oC

Liquid water
200oC
QH

W Max =??

Water 20oC
Basis perhitungan enthalpy of combustion adalah 25oC. Untuk meperhitungkan efek
preheater, seolah-olah udara panas didinginkan dahulu menjadi 25oC dengan cooler
sebelum combustion dan energy yang tersimpan pada pendinginan tersebut
dimunculkan kembali bersama dengan hasil combustion.
Qloss = 1 E6 kJ/hr
Metana = 10 kmol/hr
1 bar, 25oC Udara
Udara=120 120
Preheater kmol/hr Flue Gas 300oC
kmol/hr
1 bar, 200oC 1 bar, Water 20oC
Steam 200oC
25oC
Cooler
Liquid water
200oC
QH

W Max =??

Water 20oC

Jadi energy balance keseluruhan sistem menjadi:


𝑄𝑐𝑜𝑚𝑏𝑢𝑠𝑡𝑖𝑜𝑛 + 𝑄𝑝𝑟𝑒ℎ𝑒𝑠𝑡𝑒𝑟 + 𝑄𝑤𝑎𝑡𝑒𝑟 + 𝑄𝑙𝑜𝑠𝑠 + 𝑄𝑓𝑙𝑢𝑒 𝑔𝑎𝑠 = 0
Recall:𝑄̇𝑤𝑎𝑡𝑒𝑟 = 𝑚̇𝑤𝑎𝑡𝑒𝑟 𝑥 ∆𝐻𝑤𝑎𝑡𝑒𝑟 
−(𝑄𝑐𝑜𝑚𝑏𝑢𝑠𝑡𝑖𝑜𝑛 + 𝑄𝑝𝑟𝑒ℎ𝑒𝑠𝑡𝑒𝑟 + 𝑄𝑙𝑜𝑠𝑠 + 𝑄𝑓𝑙𝑢𝑒 𝑔𝑎𝑠 )
𝑚̇𝑤𝑎𝑡𝑒𝑟 = … … (𝑖)
∆𝐻𝑤𝑎𝑡𝑒𝑟
Basis perhitungan 1 jam:
𝑘𝑚𝑜𝑙 𝑘𝐽 𝑘𝐽
𝑄̇𝑝𝑟𝑒ℎ𝑒𝑠𝑡𝑒𝑟 = 𝑛̇ 𝐶𝑝. ∆𝑇 = 120 29 (25 − 200)𝐾 = −609000 … … (𝑖𝑖)
ℎ𝑟 𝑘𝑚𝑜𝑙.𝐾 ℎ𝑟
𝑘𝑚𝑜𝑙 𝑘𝐽 𝑘𝐽
𝑄̇𝑐𝑜𝑚𝑏𝑢𝑠𝑡𝑖𝑜𝑛 = 𝑛̇ ∆H298
𝑜
= 10 ℎ𝑟 𝑥 − 802625 𝑘𝑚𝑜𝑙 = −8026250 ℎ𝑟 … … (𝑖𝑖𝑖)
𝑄̇𝑓𝑙𝑢𝑒 𝑔𝑎𝑠 = 𝑛̇ < 𝐶𝑝 >. ∆𝑇  Perlu <Cp>
〈𝐶𝑝𝑜 〉 ∑ 𝑛𝑖 𝐵𝑖 ∑ 𝑛𝑖 𝐶𝑖 ∑ 𝑛𝑖 𝐷𝑖
Recall: = [∑ 𝑛𝑖 𝐴𝑖 + 𝑇𝑜 (𝜏 + 1) + 𝑇𝑜 2 (𝜏 2 + 𝜏 + 1) + ]
𝑅 2 3 𝜏 𝑇𝑜 2

Persamaan reaksi CH4 + 2O2 CO2 + 2H2O


Reaktan:
CH4 = 10 kmol; O2 stoikiometrik =2x10= 20 kmol; Total O2 masuk = 21% x 120
kmol =25,2 kmol; N2 dalam udara = 79% x120 kmol = 94,8 kmol (Remember Air
consist of 79% N2 and 21% O2)
Produk:
CO2 = 10 kmol; H2O = 2x10= 20 kmol; excess air = O2 masuk - O2 stoikiometrik =
25,2-20 =5,2 kmol; Inert N2 dalam udara = 94,8 kmol
Recall: ΔHp = <Cpo> (T-To)
Produk Mol A B C D
H2O 20 3,47 0,00145 … 12.100
CO2 10 5,457 0,001045 … -115.700
O2 5,2 3,639 0,000506 … -22.700
N2 94,8 3,28 0,000593 … 4000

∑ 𝑛𝑖 𝐴𝑖 = (20𝑥 3,47 + 10𝑥5,457 + 5,2𝑥 3,639 + 94,8𝑥3,28) = 453,84


Similarly: ∑ 𝑛𝑖 𝐵𝑖 = 0,098 ; ∑ 𝑛𝑖 𝐶𝑖 = 0 ; ∑ 𝑛𝑖 𝐷𝑖 = −653840
𝑇 300+273
𝜏 = 𝑇 = 25+273 = 1,923
𝑜
〈𝐶𝑝𝑜 〉 ∑ 𝑛𝑖 𝐵𝑖 ∑ 𝑛𝑖 𝐶𝑖 ∑ 𝑛𝑖 𝐷𝑖
Maka, = [∑ 𝑛𝑖 𝐴𝑖 + 𝑇𝑜 (𝜏 + 1) + 𝑇𝑜 2 (𝜏 2 + 𝜏 + 1) + ]
𝑅 2 3 𝜏 𝑇𝑜 2
〈𝐶𝑝𝑜 〉 0,098 −653840
= 453,84 + (25 + 273)(1,923 + 1) + 0 + 1,923𝑥(25+273)2 = 492,7
𝑅 2
𝑛̇ 〈𝐶𝑝𝑜 〉 = 492,7𝑥 𝑅 = 492,7 𝑥 8,314 = 4096,3 𝑘𝐽/𝐾
kJ
𝑄̇𝑓𝑙𝑢𝑒 𝑔𝑎𝑠 = 𝑛̇ 〈𝐶𝑝𝑜 〉(T − 𝑇𝑜 ) = 4096,3x(300 − 25) = 1126485 hr … … (iv)
∆𝐻𝑤𝑎𝑡𝑒𝑟 = 𝐻𝑜𝑢𝑡 − 𝐻𝑖𝑛
𝑘𝐽
𝐻𝑜𝑢𝑡 = 2790,9 𝑘𝑔 (𝑠𝑡𝑒𝑎𝑚 𝑡𝑎𝑏𝑙𝑒 𝑎𝑡 200𝑜 𝐶)

𝑘𝐽
𝐻𝑖𝑛 = 104,8 𝑘𝑔 (𝑠𝑡𝑒𝑎𝑚 𝑡𝑎𝑏𝑙𝑒 𝑎𝑡 25𝑜 𝐶)

𝑘𝐽
∆𝐻𝑤𝑎𝑡𝑒𝑟 = 2790,9 − 104,8 = 2686,1 𝑘𝑔 … … (𝑣)

Substitusi (ii) (iii) (iv) dan (v) ke (i)


−(−609000+(−8026250)+1𝑥106 +1126485) 𝑘𝑔 𝑘𝑔 ℎ𝑟 𝑘𝑔
𝑚̇𝑤𝑎𝑡𝑒𝑟 = = 2423 ℎ𝑟 = 2423 ℎ𝑟 𝑥 3600 𝑠 = 0,67
2686,1 𝑠

Tinjau heat engine


(20+273)
Carnot: 𝑒𝑓𝑓 = 1 − (200+273) = 0,38
𝑄𝐻̇ = 𝑚̇. ∆𝐻𝑙𝑎𝑡𝑒𝑛𝑡 = 0,67𝑥(2790,9 − 852,4) = 1298,86 𝑘𝐽/𝑠
𝑊 = 𝑄𝐻̇ . 𝑒𝑓𝑓 = 1298,86 𝑥 0,38 = 493,57 𝑘𝑊

4. Tinjau air dalam suatu system tertutup menerima kerja sebesar 180 W dan menyerap
kalor sebesar 30 W . Rate Qloss mengikuti persamaan −210[1 − 𝑒 −0,03 𝑡 ]. (a) Tentukan
laju perubahan energy dalam setelah 2 menit! (b) Jika system steady state berapakah
Qloss system?
Solusi:
𝑑𝑈
(a) Recall: ∆𝑈 = 𝑄 + 𝑊  = 𝑄̇ + 𝑊̇ 𝑑𝑡
𝑑𝑈
= 𝑄̇𝑙𝑜𝑠𝑠 + 𝑄̇𝑤𝑎𝑡𝑒𝑟 + 𝑊̇𝑠ℎ𝑎𝑓𝑡 = −210[1 − 𝑒 −0,03 𝑡 ] + 30 + 180 = 210[𝑒 −0,03 𝑡 ]
𝑑𝑡
Setelah 2 menit  120 sekon
𝑑𝑈
= 210(𝑒 −0,03𝑥120 ) = 5,74 𝑘𝐽/𝑠
𝑑𝑡
(b) Saat steady state dU/dt = 0 maka
𝑄̇𝑙𝑜𝑠𝑠 = −(𝑄̇𝑤𝑎𝑡𝑒𝑟 + 𝑊̇𝑠ℎ𝑎𝑓𝑡 ) = −(30 + 180) = −210 𝑊

5. Tinjau proses perpindahan panas. Untuk kasus Isentropic, Tentukan Entropi Generation
system tersebut!
Solusi:

𝑄̇
Ta= 400oC Recall Entropi Generation ∆(𝑆𝑛 )𝑓𝑠 − ∑ 𝑇 = 𝑆̇ 𝐺
𝜎

Q = 1000 J Constant S (isentropic) ∆(𝑆𝑛 )𝑓𝑠 = 0

𝑄̇ −𝑄 ̇ 𝑄 ̇ −1000 1000
o
𝑆𝐺̇ = − ∑ 𝑇 = − ( 𝑇 𝐴 + 𝑇 𝐵 ) = − (50+273 + 400+273)
Tb= 50 C 𝜎 𝐵 𝐴

(A melepas kalor sehingga bertanda minus)


𝑘𝐽
𝑆𝐺̇ = 1,61 𝐾
TK 3081 Termodinamika Dasar
UTS Modul 1
Semester 1 2013/2014

 Wajib gambarkan appropriate schematic dari problem yang Anda kerjakan


 Kecuali dinyatakan lain, semua kasus soal adalah steady state

1. (25) Ethane with molar density of 1.094 mol/liter undergoes a constant volume heating
process from 25 ℃ to 220 ℃. Based on Pitzer correlation for 2nd viral coefficient determine
the pressure of the gas at the end of the heating process. Properties of ethane: MW = 30
g/mol, 𝜔 = 1.0, Tc = 305.3 K, Pc = 48.7 bar

2. (50) Tinjau produksi steam dengan menggunakan gas hasil pembakaran metana dengan
udara berlebih 20%. Metana dan udara masuk combustion chamber pada 25 ℃, 1 bar. Kalor
yang diserap pada produksi steam 6000 kJ/s. Temperatur flue gas 140 ℃, 1 bar. Karena
insulasi buruk terjadi heat loss melalui dinding combustion chamber. Pada kondisi tersebut
laju konsumsi gas 1 MMSCFD. Melalui perbaikan insulasi Mr. Johny berhasil menurunkan
heat loss menjadi 500 kJ/s dan meningkatkan produksi steam menjadi ekivalen dengan
penyerapan kalor sebesar 7000 kJ/s. Perbaikan insulasi tidak merubah temperature flue gas
dan excess air tetap 20%. (a) Jika harga metana 10 US$/MSCF tentukan besarnya
penghematan biaya gas per hari yang dapat dicapai dari perbaikan insulasi tersebut. (b)
Setelah perbaikan insulasi, steam yang dihasilkan adalah saturated steam (x=100%) pada
100 ℃, temperatur air masuk 35 ℃. Steam digunakan sebagai heat source suatu heat engine
dengan heat sink 20 ℃. H2O keluar reservoir thermal dalam keadaan liquid (saturated
water). Tentukan kerja heat engine maksimum yang dapat dihasilkan. Entalpi penguapan
air = 2257 J/gram (pada 100℃), anggap Cp air konstan 4,18 kJ/kg.K

3. (25) Suatu alat pemroses udara mempunyai 1 inlet dan 2 outlet. Alat tersebut tidak
mempunyai moving parts (shaft work = 0). Steam inlet: udara 25℃, 5 bar; steam outlet A:
udara dingin -5℃, 1 bar; steam outlet B: udara hangat 75℃, 1 bar. Proses berlangsung
steady state dan adiabatic. Assume udara sebagai gas ideal dengan Cp = 7/2 R. Tentukan
(a) rasio laju molar udara dingin (steam A) terhadap udara hangat (steam B), (b) apakah
proses bertentangan dengan hukum kedua termodinamika? Hint: Gunakan basis stream
inlet 1 mol/menit.
TK 3081 Termodinamika Dasar
Solusi UTS Modul 1
Semester 1 2013/2014

1. (25) Ethane with molar density of 1.094 mol/liter undergoes a constant volume heating
process from 25 ℃ to 220 ℃. Based on Pitzer correlation for 2nd viral coefficient determine
the pressure of the gas at the end of the heating process. Properties of ethane: MW = 30
g/mol, 𝜔 = 1.0, Tc = 305.3 K, Pc = 48.7 bar

Jawab:

P1, T1, z1, P2, T2, z2,

V1 panasi V2

constant volume process

𝑧2 𝑅𝑇2
𝑃2 =
𝑉2
Constant volume process: V2 = V1
𝑧2 𝑅𝑇2
Then 𝑃2 =
𝑉1
Apply
𝑃𝑟2
𝑧2 = 1 + (𝐵 0 + 𝜔𝐵1 )2
𝑇𝑟2
Then
𝑃𝑟2 𝑅𝑇2
𝑃2 = 1 + (𝐵 0 + 𝜔𝐵1 )2
𝑇𝑟2 𝑉1
𝑃 𝑇2
Substitute 𝑃𝑟2 = 𝑃2 and 𝑇𝑟2 =
𝑐 𝑇𝑐
𝑃2 /𝑃𝑐 𝑅𝑇2
𝑃2 = 1 + (𝐵 0 + 𝜔𝐵1 )2
𝑇2 /𝑇𝑐 𝑉1
Rearrange to move 𝑃2 to LHS
𝑅𝑇2
𝑃2 =
𝑇
𝑉1 − (𝐵 0 + 𝜔𝐵1 )2 𝑅 𝑃𝑐
𝑐
1 1
𝑉1 diketahui dari molar density: 𝑉1 = 𝜌 = 𝑚𝑜𝑙 = 914 𝑐𝑚3 /𝑚𝑜𝑙
𝑚𝑜𝑙𝑎𝑟 1.094
𝑙𝑖𝑡𝑒𝑟
Kondisi 2 T=220℃,
𝑇 220 + 273
𝑇𝑟 = = = 1.615
𝑇𝑐 305.3
0.422
𝐵 0 = 0.083 − = −0.113
1.6151.6
0.172
𝐵1 = 0.139 − = 0.116
1.6154.2
𝑅𝑇2
Recall 𝑃2 = 𝑇
𝑉1 −(𝐵0 +𝜔𝐵1 )2 𝑅 𝑐
𝑃𝑐

Plug in numbers:
83.14 (220 + 273)
𝑃2 = = 44.92 𝑏𝑎𝑟
305.3
914 − (−0.113 + 1 × 0.116) 83.14 48.7

2. (50) Tinjau produksi steam dengan menggunakan gas hasil pembakaran metana dengan
udara berlebih 20%. Metana dan udara masuk combustion chamber pada 25 ℃, 1 bar. Kalor
yang diserap pada produksi steam 6000 kJ/s. Temperatur flue gas 140 ℃, 1 bar. Karena
insulasi buruk terjadi heat loss melalui dinding combustion chamber. Pada kondisi tersebut
laju konsumsi gas 1 MMSCFD. Melalui perbaikan insulasi Mr. Johny berhasil menurunkan
heat loss menjadi 500 kJ/s dan meningkatkan produksi steam menjadi ekivalen dengan
penyerapan kalor sebesar 7000 kJ/s. Perbaikan insulasi tidak merubah temperature flue gas
dan excess air tetap 20%. (a) Jika harga metana 10 US$/MSCF tentukan besarnya
penghematan biaya gas per hari yang dapat dicapai dari perbaikan insulasi tersebut. (b)
Setelah perbaikan insulasi, steam yang dihasilkan adalah saturated steam (x=100%) pada
100 ℃, temperatur air masuk 35 ℃. Steam digunakan sebagai heat source suatu heat engine
dengan heat sink 20 ℃. H2O keluar reservoir thermal dalam keadaan liquid (saturated
water). Tentukan kerja heat engine maksimum yang dapat dihasilkan. Entalpi penguapan
air = 2257 J/gram (pada 100℃), anggap Cp air konstan 4,18 kJ/kg.K
Qloss
Jawab: metana
25 ℃
1 bar fluegas
140 ℃
1 bar
udara berlebih 20%
25 ℃
water
1 bar
35 ℃
saturated
100℃
x=100%
liquid 100℃
QH
??

water 20 ℃
(a) Kalor hasil pembakaran sebagian diserap untuk steam, sebagian terbawa oleh flue gas,
dan sebagian hilang, maka
𝑛̇ (∆𝐻°298 + ∆𝐻°𝑃 ) + 𝑄̇𝑤𝑎𝑡𝑒𝑟 + 𝑙𝑜𝑠𝑠𝑒𝑠 = 0

Kalor ke water dan Qloss diketahui:


𝑄̇𝑤𝑎𝑡𝑒𝑟 + 𝑙𝑜𝑠𝑠𝑒𝑠 = 7000 + 500 = 7500 𝑘𝐽/𝑠

Hitung ∆𝐻°𝑃 :
CH4 + 2O2  CO2 + 2H2O
Basis CH4 = 1 mol
Reaktan: CH4 = 1 mol
O2 kalau stoikiometric = 2 mol, total O2 masuk = 2(1+0.2) = 2.4 mol
N2 dalam udara = 79/21 x 2.4 = 9.0286 mol
Produk: CO2 = 1 mol
H2O = 2 mol
Excess O2 = O2 masuk – O2 stoikiometric = 2.4 – 2 = 0.4 mol
Inert N2 = 9.0286 mol
Recall ∆𝐻°𝑃 = 〈𝐶𝑝°〉(𝑇𝑝 − 𝑇0 )
〈𝐶𝑝°〉 ∑ 𝑛𝑖 𝐵𝑖 ∑ 𝑛𝑖 𝐷𝑖
Recall = [∑ 𝑛𝑖 𝐴𝑖 + 𝑇0 (𝜏 + 1) + ]…………………(A)
𝑅 2 𝜏𝑇02
Nilai Ai, Bi, Ci didapatkan dari tabel berikut
Mol A B D
H2 O 2 3.47 0.00145 12100
CO2 1 5.457 0.001045 -115700
O2 0.4 3.639 0.000506 -22700
N2 9.0286 3.28 0.000593 4000

Jadi,
∑ 𝑛𝑖 𝐴𝑖 = 2(3.47) + 1(5.457) + 0.4(3.639) + 9.0286(3.28) = 43.471
Similarly, ∑ 𝑛𝑖 𝐵𝑖 = 0.009502, ∑ 𝑛𝑖 𝐷𝑖 = −64509.8
140+273
T = 140 ℃  𝜏 = = 1.386
25+273
Plug in known values into (A):
〈𝐶𝑝°〉 0.009502 −64509.8
= [43.471 + 298(1.386 + 1) + ] = 46.325
𝑅 2 2982 (1.386)
𝐽
〈𝐶𝑝°〉 = 46.325 × 8.314 = 385.1 .𝐾
𝑚𝑜𝑙
𝐽
∆𝐻°𝑃 = 385.1(140 − 25) = 44287
𝑚𝑜𝑙 𝐶𝐻4
𝐽
∆𝐻°298 = −802625
𝑚𝑜𝑙 𝐶𝐻4
Recall
𝑛̇ (∆𝐻°298 + ∆𝐻°𝑃 ) + 𝑄̇𝑤𝑎𝑡𝑒𝑟 + 𝑙𝑜𝑠𝑠𝑒𝑠 = 0
𝑄̇𝑤𝑎𝑡𝑒𝑟 + 𝑙𝑜𝑠𝑠𝑒𝑠 7500
𝑛̇ = = = 0.00989 𝑘𝑚𝑜𝑙/𝑠
−(∆𝐻°298 + ∆𝐻°𝑃 ) −(−802625 + 44287)
Convert to MMSCFD
Rate CH4:
𝑘𝑚𝑜𝑙 𝑙𝑏 𝑙𝑏𝑚𝑜𝑙
𝑛̇ = 0.00989 × 2.2046 = 0.0218
𝑠 𝑘𝑔 𝑠
Volume rate CH4:
𝑆𝐶𝐹 𝑙𝑏𝑚𝑜𝑙 𝑆𝐶𝐹
380 × 0.0218 = 8.285
𝑙𝑏𝑚𝑜𝑙 𝑠 𝑠
Volume rate CH4:
𝑆𝐶𝐹 𝑠𝑒𝑐 𝑀𝑀𝑆𝐶𝐹
8.285 × 86400 × = 0.716 𝑀𝑀𝑆𝐶𝐹𝐷
𝑠 𝑑𝑎𝑦 106 𝑆𝐶𝐹
Penghematan gas: (1 – 0.716) = 0.284 MMSCFD
Penghematan biaya gas: 0.284 MMSCFD x 10 US$/MSCF = 2841 US$/day

(b) Hitung W engine max = QH x Eff Carnot  perlu QH


QH dari 𝑚̇∆𝐻𝑘𝑜𝑛𝑑𝑒𝑛𝑠  perlu mass rate  dari Q yang diserap air

𝑄𝑠𝑒𝑟𝑎𝑝 𝑎𝑖𝑟 = 𝑚̇(𝐶𝑝∆𝑇 + ∆𝐻𝑒𝑣𝑎𝑝 )

𝑄𝑠𝑒𝑟𝑎𝑝 𝑎𝑖𝑟 7000


𝑚̇ = = = 2.768 𝑘𝑔/𝑠
(𝐶𝑝∆𝑇 + ∆𝐻𝑒𝑣𝑎𝑝 ) 4.18(100 − 35) + 2257

𝑄𝐻 = 𝑚̇∆𝐻𝑘𝑜𝑛𝑑𝑒𝑛𝑠 = 2.768 × 2257 = 6247 𝑘𝐽/𝑠


𝑇 273+20
Carnot Eff: 𝜂𝑐𝑎𝑟𝑛𝑜𝑡 = 1 − 𝑇 𝐶 = 1 − 273+100 = 0.21
𝐻

𝑊 𝑚𝑎𝑥 = 𝜂𝑐𝑎𝑟𝑛𝑜𝑡 × 𝑄𝐻 = 0.21 × 6247 = 1311.87 𝑘𝑊 = 1.312 𝑀𝑊

3. (25) Suatu alat pemroses udara mempunyai 1 inlet dan 2 outlet. Alat tersebut tidak
mempunyai moving parts (shaft work = 0). Steam inlet: udara 25℃, 5 bar; steam outlet A:
udara dingin -5℃, 1 bar; steam outlet B: udara hangat 75℃, 1 bar. Proses berlangsung
steady state dan adiabatic. Assume udara sebagai gas ideal dengan Cp = 7/2 R. Tentukan
(a) rasio laju molar udara dingin (steam A) terhadap udara hangat (steam B), (b) apakah
proses bertentangan dengan hukum kedua termodinamika? Hint: Gunakan basis stream
inlet 1 mol/menit.
Jawab: A: -5 ℃, 1 bar
25 ℃, 5 bar
device
B: 75 ℃, 1 bar

(a) Inlet 1 mol/s, basis 1 second:

Steady state  mol stream A+B = mol stream inlet = 1

Let mol stream A = xA, jadi mol stream B, xB = 1 – xA

No work,  Q = ΔH but adiabatic  Q = 0 ΔH = 0

ΔH = xACp(TA–Tinlet) + (1-xA)Cp(TB-Tinlet) = 0

xA(-5-25) + (1-xA)(75-25) = 0  xA = 5/8 maka xB = 3/8

Jadi rasio udara dingin terhadap udara hangat = 5/3

(b) Ideal gas entropy changes:


𝑇 𝑖𝑔
∆𝑆 𝐶𝑝 𝑑𝑇 𝑃
= ∫ − ln
𝑅 𝑅 𝑇 𝑃0
𝑇0

𝑇𝐴 𝑇𝐵 𝑃
∆𝑆 = 𝑥𝐴 𝐶𝑝 ln + 𝑥𝐵 𝐶𝑝 ln − 𝑅 ln
𝑇𝑖𝑛𝑙𝑒𝑡 𝑇𝑖𝑛𝑙𝑒𝑡 𝑃𝑖𝑛𝑙𝑒𝑡

where Cp = 7/2 R
𝐽
Plug in values ∆𝑆 = 15.04 𝑚𝑜𝑙.𝐾  ∆𝑆 positif, jadi tidak bertentangan dengan hukum II
TK 3081 Termodinamika Dasar
Ujian Perbaikan Modul 1
Semester 1 2013/2014

1. (15) Suatu zat (A) mempunyai critical properties: TC = 418 K and PC = 40 bar. Dew point
zat A: 10 bar, 325 K. Dengan EOS Redlich Kwong tentukan besarnya vapor molar volume
(cm3/mol) zat A pada dew point-nya.

2. (35) Tinjau suatu bejana logam tertutup 1.5 m3 berisi campuran air & uap air pada 100℃.
Berat campuran air & uap air dalam bejana 500 kg. Pada suatu saat t=t air dingin 70℃
dikucurkan ke dalam bejana (melalui suatu valve) dengan laju massa 750 kg per jam. Agar
P dan T dalam bejana tidak berubah, bejana tersebut dipanasi dengan laju input kalor Q
(kJ/jam). Tentukan besarnya Q.

3. (35) Tinjau suatu steam boiler dilengkapi air preheater berbahan bakar natural gas dengan
data sebagai berikut:

Masuk Keluar Rate


Natural gas 25℃, 1 bar - 50 kmol/jam
Udara 200℃, 1 bar - 600 kmol jam
Water 25℃, sat liquid 200℃, sat vapor ?? kg/s
Floe gas - 300℃, 1 bar ?? MMSCFD

Anggap natural gas = 100% metana


Heat loss melalui dinding combustion chamber = 5x106 kJ/hr
Pada range 25 – 200℃, Cp udara rata-rata = 1 kJ/kg.K
Berat molekul: CH4 = 16 gram/mol, udara = 29 gram/mol
Pembakaran metana: ∆𝐻°298 = -802625 J/mol metana
Tentukan laju massa steam (kg/s) dan laju volume flue gas (MMSCFD).
Note: air preheater = alat untuk memanasi udara sebelum masuk combustion chamber

4. (15) Tinjau proses pencampuran+pemanasan gas ideal A dan B dalam suatu


mixing+heating chamber. Laju masuk gas A sama dengan gas B yaitu masing-masing 1
mol/jam. Temperatur inlet gas A dan B masing-masing 600 K dan 400 K. Pemanasan
chamber menggunakan nyala api hasil pembakaran natural gas. Tentukan temperatur
minimum nyala api agar temperatur campuran gas A+B keluar chamber mencapai 550 K.
Anggap property gas dalam chamber homogen Cp gas ideal = 7/2 R (di mana R universal
gas constant)
TK 3081 Termodinamika Dasar
Solusi Ujian Perbaikan Modul 1
Semester 1 2013/2014

1. (15) Suatu zat (A) mempunyai critical properties: TC = 418 K and PC = 40 bar. Dew point
zat A: 10 bar, 325 K. Dengan EOS Redlich Kwong tentukan besarnya vapor molar volume
(cm3/mol) zat A pada dew point-nya.

Jawab:

Generic cubic:
𝑅𝑇 𝛼(𝑇)
𝑃= −
𝑉 − 𝑏 (𝑉 + 𝜖𝑏)(𝑉 + 𝜎𝑏)
For Redlich Kwong EOS, 𝜖 = 0, 𝜎 = 1 (see tabel)
Maka vapor-like dari RK:
𝑅𝑇 𝛼(𝑇)(𝑉 − 𝑏)
𝑉= +𝑏−
𝑃 𝑃𝑉(𝑉 + 𝑏)
dengan
𝛼(𝑇𝑟 )𝑅 2 𝑇𝑐2
𝛼(𝑇) = 𝛹
𝑃𝑐
𝑅𝑇𝑐
𝑏=Ω
𝑃𝑐
1

For RK: Ω = 0.08664, 𝛼(𝑇𝑟 ) = 𝑇𝑐 2 , 𝛹 = 0.42748 (see table)
𝛼(𝑇𝑟 )𝑅 2 𝑇𝑐2 𝑅𝑇𝑐
Plug in numbers: 𝛼(𝑇) = 𝛹 = 14,637,768 𝑏=Ω = 75.27
𝑃𝑐 𝑃𝑐
𝑅𝑇 𝛼(𝑇)(𝑉𝑖 − 𝑏)
𝑉𝑖+1 = +𝑏−
𝑃 𝑃𝑉𝑖 (𝑉𝑖 + 𝑏)
Guess 1:
𝑅𝑇 325
𝑉0 = = 83.14 ∗ = 2702 𝑐𝑚3 /𝑚𝑜𝑙
𝑃 10
i = 0:
325 14637768 2702 − 75.27
𝑉1 = 83.14 + 75.27 − = 2264.9
10 10 2702(2702 + 75.27)
i = 1:
325 14637768 2264.9 − 75.27
𝑉2 = 83.14 + 75.27 − = 2172.6
10 10 2264.9(2264.9 + 75.27)
Iterasi seterusnya konvergen pada V = 2140 cm3/mol
2. (35) Tinjau suatu bejana logam tertutup 1.5 m3 berisi campuran air & uap air pada 100℃.
Berat campuran air & uap air dalam bejana 500 kg. Pada suatu saat t=t air dingin 70℃
dikucurkan ke dalam bejana (melalui suatu valve) dengan laju massa 750 kg per jam. Agar
P dan T dalam bejana tidak berubah, bejana tersebut dipanasi dengan laju input kalor Q
(kJ/jam). Tentukan besarnya Q.

Jawab:

Vol=1.5 m3, m=500 kg


Water addition
70 ℃, 𝑚̇ = 750 kg/s
Water
100 ℃, 101.33kPa
Agar P & T tidak berubah oleh
penambahan air dingin tentukan Q

Recall energy balance:


𝑑(𝑚𝑈)𝐶𝑉 1
+ ∆ [(𝐻 + 𝑢2 + 𝑧𝑔) 𝑚̇] = 𝑄̇ + 𝑊̇
𝑑𝑡 2 𝑓𝑠

∆𝑢2 = ∆𝑧 = 0 and 𝑊 = 0

Then
𝑑(𝑚𝑈)𝐶𝑉
̇ ) = 𝑄̇
̇ ) − (𝑚𝐻
+ (𝑚𝐻
𝑑𝑡 𝑜𝑢𝑡 𝑖𝑛

𝑚̇𝑜𝑢𝑡 = 0 and let 𝑚̇𝑖𝑛 = 𝑚̇′ , 𝐻𝑖𝑛 = 𝐻′

Energy balance:
𝑑(𝑚𝑈)𝑡𝑎𝑛𝑘
− 𝐻 ′ 𝑚̇′ = 𝑄̇
𝑑𝑡
Mass balance:
𝑑𝑚𝑡𝑎𝑛𝑘
𝑚̇′ =
𝑑𝑡
Combine these two equations:
𝑑(𝑚𝑈)𝑡𝑎𝑛𝑘 𝑑𝑚𝑡𝑎𝑛𝑘
− 𝐻′ = 𝑄̇
𝑑𝑡 𝑑𝑡
Multiplication by dt:
∆(𝑚𝑈)𝑡𝑎𝑛𝑘 − 𝐻 ′ ∆𝑚𝑡𝑎𝑛𝑘 = 𝑄

Recall definition of U: 𝐻 = 𝑈 + 𝑃𝑉  𝑈 = 𝐻 − 𝑃𝑉

∆(𝑚𝑈)𝑡𝑎𝑛𝑘 = ∆(𝑚𝐻)𝑡𝑎𝑛𝑘 − ∆(𝑃𝑚𝑉)𝑡𝑎𝑛𝑘

mV = volume tank = konstan

∆(𝑃𝑚𝑉)𝑡𝑎𝑛𝑘 = 0

∆(𝑚𝑈)𝑡𝑎𝑛𝑘 = ∆(𝑚𝐻)𝑡𝑎𝑛𝑘

𝑄 = ∆(𝑚𝐻)𝑡𝑎𝑛𝑘 − 𝐻 ′ ∆𝑚𝑡𝑎𝑛𝑘 = (𝑚2 𝐻2 − 𝑚1 𝐻1 )𝑡𝑎𝑛𝑘 − 𝐻 ′ ∆𝑚𝑡𝑎𝑛𝑘

∆𝑚𝑡𝑎𝑛𝑘 = 750 𝑘𝑔 (air yang masuk tank)

From steam table

𝐻 ′ = 293.0 𝑘𝐽/𝑘𝑔  saturated liquid at 70 ℃ (added water)

𝐻 𝑙 = 419.1 𝑘𝐽/𝑘𝑔  saturated liquid at 100 ℃ (inside tank)

𝐻 𝑣 = 2676.0 𝑘𝐽/𝑘𝑔  saturated vapor at 100 ℃ (inside tank)

Initial condition:

Vol vapor = (vol tank) – (vol of 500 kg liquid water)

Vol liq water = (mass) x (specific volume of liquid water)

Specific volume of liquid water at 100 ℃ = 0.001044 m3/kg

Mass of vapor = m1v = (vol vapor) / (specific vol of vapor)

Specific vol of water vapor at 100 ℃ = 1.673 m3/kg


1.5−(500)(0.001044)
Maka 𝑚1𝑣 = = 0.5846 𝑘𝑔
1.673

Total entalphy in the tank:

(𝑚1 𝐻1 )𝑡𝑎𝑛𝑘 = 𝑚1𝑙 𝐻1𝑙 + 𝑚1𝑣 𝐻1𝑣 = 500(419.1) + 0.5846(2,676.0) = 211,114 𝑘𝐽

At the end of the process (state 2), from mass balance:


𝑚 𝑡𝑜𝑡𝑎𝑙, 𝑠𝑡𝑎𝑡𝑒 2 = 𝑚2 = 𝑚2𝑙 + 𝑚2𝑣 = (𝑚 𝑣𝑎𝑝𝑜𝑟 + 𝑚 𝑙𝑖𝑞𝑢𝑖𝑑)2 + 𝑚 𝑎𝑑𝑑𝑒𝑑 𝑤𝑎𝑡𝑒𝑟
= (500 + 0.5846 + 750 = 1250.5846 𝑘𝑔

then

𝑚2𝑙 + 𝑚2𝑣 = 1250.5846 𝑘𝑔

Also,

Total volume = (vol vapor + vol liquid water)state 2

= (specific vol vapor x mass vapor)2 + (specific vol liquid x mass liquid)2

1.5 = 1.673 m2v + 0.001044 m2l

Recall 𝑚2𝑙 + 𝑚2𝑣 = 1250.5846

Two equations with two unknowns: 𝑚2𝑙 = 1,250.4683 𝑘𝑔, 𝑚2𝑣 = 0.116 𝑘𝑔

Total enthalpy inside the tank at state 2:

(𝑚2 𝐻2 )𝑡𝑎𝑛𝑘 = 𝑚𝑙2 𝐻2𝑙 + 𝑚2𝑣 𝐻2𝑣

Since PT at initial condition = PT at final condition  𝐻2𝑙 = 𝐻1𝑙 and 𝐻2𝑣 = 𝐻1𝑣

So,

(𝑚2 𝐻2 )𝑡𝑎𝑛𝑘 = 𝑚𝑙2 𝐻1𝑙 + 𝑚2𝑣 𝐻1𝑣

(𝑚2 𝐻2 )𝑡𝑎𝑛𝑘 = 1,250.4683(419.1) + 0.116(2,676.0) = 524,382 𝑘𝐽

Recall

𝑄 = (𝑚2 𝐻2 − 𝑚1 𝐻1 )𝑡𝑎𝑛𝑘 − 𝐻 ′ ∆𝑚𝑡𝑎𝑛𝑘

𝑄 = 524,382 − 211,114 − 750(293.0) = 93,518 𝑘𝐽

3. (35) Tinjau suatu steam boiler dilengkapi air preheater berbahan bakar natural gas dengan
data sebagai berikut:

Masuk Keluar Rate


Natural gas 25℃, 1 bar - 50 kmol/jam
Udara 200℃, 1 bar - 600 kmol jam
Water 25℃, sat liquid 200℃, sat vapor ?? kg/s
Floe gas - 300℃, 1 bar ?? MMSCFD
Anggap natural gas = 100% metana
Heat loss melalui dinding combustion chamber = 5x106 kJ/hr
Pada range 25 – 200℃, Cp udara rata-rata = 1 kJ/kg.K
Berat molekul: CH4 = 16 gram/mol, udara = 29 gram/mol
Pembakaran metana: ∆𝐻°298 = -802625 J/mol metana
Tentukan laju massa steam (kg/s) dan laju volume flue gas (MMSCFD).
Note: air preheater = alat untuk memanasi udara sebelum masuk combustion chamber

Jawab:
CH3
Qloss = 5x106 kJ/hr
50 kmol/jam
Boiler
25 ℃
1 bar fluegas
air preheater 300 ℃ 𝑛̇ 𝑓𝑙𝑢𝑒 𝑔𝑎𝑠 =?
1 bar
udara
600 kmol/jam
200 ℃ sat vapor
1 bar 200 ℃

sat liquid 25 ℃ 𝑚̇ =?

Basis perhitungan entalpi of combustion adalah 25 ℃. Untuk memperhitungkan efek


preheater, seolah-olah udara panas didinginkan dahulu menjadi 25 ℃ sebelum combustion
dan energi yang tersimpan pada pendinginan tersebut dimunculkan kembali bersama
dengan energi hasil combustion.

Jadi, energy balance menjadi: 𝑄𝑐𝑜𝑚𝑏𝑢𝑠𝑡𝑖𝑜𝑛 + 𝑄𝑝𝑟𝑒ℎ𝑒𝑎𝑡𝑒𝑟 = 𝑄𝑤𝑎𝑡𝑒𝑟 + 𝑄𝑙𝑜𝑠𝑠 + 𝑄𝑓𝑙𝑢𝑒 𝑔𝑎𝑠

(𝑄𝑐𝑜𝑚𝑏𝑢𝑠𝑡𝑖𝑜𝑛 +𝑄𝑝𝑟𝑒ℎ𝑒𝑎𝑡𝑒𝑟 )−(𝑄𝑙𝑜𝑠𝑠 + 𝑄𝑓𝑙𝑢𝑒 𝑔𝑎𝑠 )


𝑄𝑤𝑎𝑡𝑒𝑟 = 𝑚𝑎𝑠𝑠 . ∆𝐻  𝑚𝑤𝑎𝑡𝑒𝑟 = ∆𝐻𝑤𝑎𝑡𝑒𝑟

Basis perhitungan 1 jam

𝑘𝐽
𝑄𝑝𝑟𝑒ℎ𝑒𝑎𝑡𝑒𝑟 = 𝑛𝐶𝑝 ∆𝑇 = 600 𝑘𝑚𝑜𝑙 x 29 x (300 − 25)𝐾 = 3,045,000 𝑘𝐽
𝑘𝑚𝑜𝑙. 𝐾
𝑘𝐽
𝑄𝑐𝑜𝑚𝑏𝑢𝑠𝑡𝑖𝑜𝑛 = 𝑛∆𝐻 = 50 𝑘𝑚𝑜𝑙 x 802625 = 40,131,250 𝑘𝐽
𝑘𝑚𝑜𝑙
𝑄𝑓𝑙𝑢𝑒 𝑔𝑎𝑠 = 𝑚𝑜𝑙 x < 𝐶𝑝 > ∆𝑇
Moles of combustion products:

𝐶𝑂2 50 𝑚𝑜𝑙 𝑂2 26 𝑚𝑜𝑙

𝐻2 𝑂 100 𝑚𝑜𝑙 𝑁2 474 𝑚𝑜𝑙

Mol x constants (constants from table):

nA nB nC
CO2 272.9 0.0523 5,785,000
H2 O 347.0 0.1450 1,210,000
O2 94.6 0.0132 590,200
N2 1,554.7 0.2811 1,896,000
sum 2,269.2 0.4915 3,269,200

∑𝑖 𝑛𝑖 𝐵𝑖 ∑𝑖 𝑛𝑖 𝐷𝑖
∑ 𝑛𝑖 𝐴𝑖 + 𝑇0 (𝜏 + 1) + = 2,269.2 + 214 + (−19.15) = 2,464
2 𝜏𝑇02
𝑖

<Cp> = 8.314 x 2,464 = 20,468 kJ/K

<Cp>ΔT = 20,468 x (300-25) = 5,633,752 kJ (energi untuk pemanasan combustion


product)

Hwater in = 104.8 kJ/kg, Hwater out = 2790.9 kJ/kg


(40,131,250+3,045,000 )–(5,000,000+5,633,752 )
So, 𝑚𝑤𝑎𝑡𝑒𝑟 = = 12,115 kg
2790.9−104.8

Jadi laju air = 12.1 kg per jam (3.36 kg/s)

Flow rate flue gas = flow rate gas masuk = 600+50 kmol/jam
𝑘𝑚𝑜𝑙 𝑙𝑏𝑚𝑜𝑙 𝑠𝑐𝑓 𝑗𝑎𝑚 𝑀𝑀𝑆𝐶𝐹
Flue gas = 650 2.2 𝑘𝑚𝑜𝑙 379 𝑙𝑏𝑚𝑜𝑙 24 𝑑𝑎𝑦 = 13 𝑀𝑀𝑆𝐶𝐹𝐷
𝑗𝑎𝑚 106 𝑠𝑐𝑓
4. (15) Tinjau proses pencampuran+pemanasan gas ideal A dan B dalam suatu
mixing+heating chamber. Laju masuk gas A sama dengan gas B yaitu masing-masing 1
mol/jam. Temperatur inlet gas A dan B masing-masing 600 K dan 400 K. Pemanasan
chamber menggunakan nyala api hasil pembakaran natural gas. Tentukan temperatur
minimum nyala api agar temperatur campuran gas A+B keluar chamber mencapai 550 K.
Anggap property gas dalam chamber homogen Cp gas ideal = 7/2 R (di mana R universal
gas constant)

Jawab: 550 K

Gas A Gas B

1 mol/hr 1 mol/hr
600 K 400 K

Cp = 7/2 R

Recall
𝑄̇ ∑ 𝑄̇
∆𝑆̇ = ∑ + 𝑆𝐺̇ = + 𝑆𝐺̇
𝑇 𝑇
Temperatur minimum  𝑆𝐺̇ = 0
∑ 𝑄̇ = 𝑛̇ 𝐴 𝐶𝑝∆𝑇𝐴 + 𝑛̇ 𝐵 𝐶𝑝∆𝑇𝐵
7 7
= 1× ×8.314×(550 − 600) + 1× ×8.314×(550 − 400)
2 2
= 2909.9 𝑘𝐽/ℎ𝑟
550 550
𝑑𝑇 𝑃 𝑑𝑇 𝑃
∆𝑆̇ = ∆𝑆𝐴̇ + ∆𝑆𝐵̇ = ∫ 𝑛̇ 𝐴 𝐶𝑝 + 𝑅 𝑙𝑛 + ∫ 𝑛̇ 𝐵 𝐶𝑝 − 𝑅 𝑙𝑛
𝑇 𝑃𝑂 𝑇 𝑃𝑂
600 400
550 550
7 𝑑𝑇 7 𝑑𝑇 7 550 7 550
= ∫ 𝑛̇ 𝐴 𝑅 + ∫ 𝑛̇ 𝐵 𝑅 = 8.314 ln + 8.314 ln
2 𝑇 2 𝑇 2 600 2 400
600 400
𝑘𝐽
= 6.735 ⁄ℎ𝑟. 𝐾
Maka
∑ 𝑄̇ 2909.9
𝑇= = = 432.073 𝐾
∆𝑆̇ 6.735
TERMODINAMIKA
DASAR A
MODUL II
TK 3081-Termodika Dasar A
Perbaikan Modul 2 2009/2010
1. Show that isothermal ideal gas mixing is an irreversible process!
2. Diketahui suatu zat pada 280oC mempunyai data P vs Z berikut:

P, bar 20 35 50 65
Z 0,940 0,886 0,824 0,755
Tentukan secara grafis fugasitas gas tersebut pada 280oC, 60 bar! Tuliskan dengan jelas
prosedur penyelsaian soal!

3. Tinjau suatu power plant siklus Rankine berbahan bakar gas bumi dengan kondisi
operasi: boiler-superheater 8,8 Mpa, 475oC, condenser 80oC. Efisiensi turbin dan
popmpa masing-masing 75%. Tentukan laju gas bumi (MMSCFD) untuk
menghasilkan daya sebesar 10 MW. Heating value gas bumi : 1000 BTU/SCF
4. Tentukan mole rate dan komposisi masing-masing stream pada gambar berikut.
Assume campuran mengikuti Hukum Raoult.

80oC, 110 kPa


Rate =?? mol/hr
{yi} = ?? Pada 80oC:
Rate: 20 mol/hr
80oC
135 kPa; 80oC  PsatA = 196kPa
110 kPa  PsatB = 98kPa
{zi}:
A= 45%  PsatC = 50kPa
Rate =?? mol/hr
B= 35%
{xi} = ??
C= 20%
80oC, 110 kPa

Soal Bonus: Jelaskan aplikasi fugasitas di teknik perminyakan (nantinya untuk


menghitung apa? Menyelesaikan persoalan apa?)
SOLUSI
TK 3081-Termodika Dasar A
Perbaikan Modul 2 2009/2010
1.Show that isothermal ideal gas mixing is an irreversible process!
Solusi:
We need these relations
- Irreversible process  ΔS=0
- Gibb’s theorem  𝑀 ̅𝑖𝑖𝑔 (𝑇, 𝑃) = 𝑀𝑖𝑖𝑔 (𝑇, 𝑃𝑖 )
- Summability relation  𝑀 = ∑𝑖 𝑥𝑖 𝑀 ̅𝑖
𝑑𝑇 𝜕𝑉
Recall: 𝑑𝑆 = 𝐶𝑝 − ( ) 𝑑𝑃
𝑇 𝜕𝑇 𝑃
𝜕𝑉
Untuk kasus isothermal dT=0  𝑑𝑆 = − ( ) 𝑑𝑃
𝜕𝑇 𝑃
Recall ideal gas equation P.V=R.T
𝜕𝑉 𝑅
V= R.T/P  (𝜕𝑇 ) = 𝑃
𝑃
Maka
𝑖𝑔 𝑅
𝑑𝑆𝑖 = − ( ) 𝑑𝑃
𝑃
Integrasi
𝑃 𝑖𝑔 𝑃 𝑅 𝑃
∫𝑃 𝑑𝑆𝑖 = ∫𝑃 − (𝑃) 𝑑𝑃 = −𝑅 ln 𝑃
𝑖 𝑖 𝑖
1 𝑃
Recall partial properties Pi= xi P  =𝑃
𝑥𝑖 𝑖
𝑃 𝑖𝑔 𝑖𝑔 𝑖𝑔
∫𝑃 𝑑𝑆𝑖 = 𝑆𝑖 (𝑇, 𝑃) − 𝑆𝑖 (𝑇, 𝑃𝑖 )
𝑖
Substitusi
𝑃 𝑖𝑔 𝑃 𝑅 𝑃
∫𝑃 𝑑𝑆𝑖 = ∫𝑃 − (𝑃) 𝑑𝑃 = −𝑅 ln 𝑃
𝑖 𝑖 𝑖
𝑖𝑔 𝑖𝑔 1
𝑆𝑖 (𝑇, 𝑃) − 𝑆𝑖 (𝑇, 𝑃𝑖 ) = −𝑅 ln 𝑥 = 𝑅 ln 𝑥𝑖
𝑖
𝑖𝑔 𝑖𝑔
𝑆𝑖 (𝑇, 𝑃𝑖 ) = 𝑆𝑖 (𝑇, 𝑃) − 𝑅 ln 𝑥𝑖
Recall Gibb’s Theorem ̅𝑖𝑖𝑔 (𝑇, 𝑃) = 𝑀𝑖𝑖𝑔 (𝑇, 𝑃𝑖 )
𝑀
𝑖𝑔 𝑖𝑔
Maka 𝑆 (𝑇, 𝑃𝑖 ) = 𝑆̅ (𝑇, 𝑃)
𝑖 𝑖
Substitusi
𝑖𝑔 𝑖𝑔
𝑆𝑖̅ (𝑇, 𝑃) = 𝑆𝑖 (𝑇, 𝑃) − 𝑅 ln 𝑥𝑖
𝑖𝑔 𝑖𝑔
𝑆𝑖̅ = 𝑆𝑖 − 𝑅 ln 𝑥𝑖
Recall Summability relation  𝑀 = ∑𝑖 𝑥𝑖 𝑀 ̅𝑖
𝑖𝑔 𝑖𝑔
Maka: 𝑆𝑖 = ∑𝑖 𝑥𝑖 𝑆𝑖̅
Substitusi
𝑖𝑔 𝑖𝑔
𝑆𝑖 = ∑𝑖 𝑥𝑖 (𝑆𝑖 − 𝑅 ln 𝑥𝑖 )
𝑖𝑔 𝑖𝑔
𝑆𝑖 = ∑𝑖 𝑥𝑖 𝑆𝑖 − ∑𝑖 𝑥𝑖 (𝑅 ln 𝑥𝑖 )
𝑖𝑔 𝑖𝑔
𝑆𝑖 − ∑𝑖 𝑥𝑖 𝑆𝑖 = − ∑𝑖 𝑥𝑖 (𝑅 ln 𝑥𝑖 )
𝑖𝑔
∆𝑆𝑖 (𝑚𝑖𝑥𝑖𝑛𝑔) = −𝑅 ∑𝑖 𝑥𝑖 ln 𝑥𝑖
𝑖𝑔 1
∴ ∆𝑆𝑖 (𝑚𝑖𝑥𝑖𝑛𝑔) = 𝑅 ∑ 𝑥𝑖 ln
𝑥𝑖
𝑖
Karena nilai R > 0, dan xi < 1 maka ln 1/xi berharga + (positif) sehingga dapat
𝑖𝑔
disimpulkan ∆𝑆𝑖 (𝑚𝑖𝑥𝑖𝑛𝑔) > 0
2.Diketahui suatu zat pada 280oC mempunyai data P vs Z berikut:

P, bar 20 35 50 65
Z 0,940 0,886 0,824 0,755
o
Tentukan secara grafis fugasitas gas tersebut pada 280 C, 60 bar! Tuliskan dengan jelas
prosedur penyelesaian soal!

Solusi:
𝑃 𝑑𝑃
Recall: ln 𝜙𝑖 = ∫0 (𝑧𝑖 − 1) 𝑃

𝑓 𝑃 𝑑𝑃
ln 𝑃𝑖 = − ∫0 (1 − 𝑧𝑖 ) 𝑃

𝑓𝑖 𝑃 𝑑𝑃
= exp − ∫0 (1 − 𝑧𝑖 )
𝑃 𝑃

𝑃 𝑑𝑃
𝑓𝑖 = 𝑃. exp − ∫0 (1 − 𝑧𝑖 ) … … (𝑖)
𝑃

𝑃 𝑑𝑃
∫0 (1 − 𝑧𝑖 ) 𝑃
didapat dari luas grafik

Dari data pada table hitung (1-zi)/P untuk setiap tekanan


(1−𝑧𝑖 ) 1−0,94
untuk P= 20  = = 0,003
𝑃 20

Hasil akhir

P,bar 20 35 50 65
Z 0,94 0,886 0,824 0,755
(1-Z)/P 0,003 0,0032 0,00352 0,00377
Plot data P vs (1-Z)/P pada grafik

Gunakan regresi linear untuk mencari persamaan kurva (Ask assistant for detail)
0.005

0.004 y =1,753 E-5x + 0.00263

0.003

(1-Z)/P Area
0.002 b
a t
0.001

0
0 10 20 30 40 50 60 70 80 90 100
P,bar

Dari grafik dapat dilihat daerah di bawah grafik berupa trapezium

a= 0,00263; b= 0,00368; t = 60

Luas = (a+b)/2 x t = (0,00263+0,00368)/2 x 60 = 0,1893

Substitusi ke (i)

𝑓𝑖 = 𝑃. exp(−Luas)

𝑓𝑖 = 60 𝑥 𝑒 −0,1893 = 49,65 𝑝𝑠𝑖

3.Tinjau suatu power plant siklus Rankine berbahan bakar gas bumi dengan kondisi
operasi: boiler-superheater 8,8 Mpa, 475oC, condenser 80oC. Efisiensi turbin dan pompa
masing-masing 75%. Tentukan laju gas bumi (MMSCFD) untuk menghasilkan daya
sebesar 10 MW. Heating value gas bumi : 1000 BTU/SCF
Solusi:
8,8 Mpa 475oC
1 2

Nat gas: ??? MMSCFD


Heat val: 1000 BTU/scf η=75% 10 MW
η=75%

4 3
Condenser
80oC Qcondenser
Tinjau boiler (12)
P=8,8 MPa = 8800 kPa
T= 475oC
H2= 3326,5 ; S2= 6,5904 (steam table superheated steam)

Tinjau turbin (23)


Karena condenser beroperasi pada 80oC didapat properties steam keluar turbin
S’3l= 1,0753; S’3v=7,6132; H’3l= 334,9; H’3v= 2643,8 (steam table at 80oC)
Tinjau kasus isentropic
S2=S’3= 6,5904
Karena S’3l < S’3< S’3v maka steam keluar turbin memiliki 2 fasa
Find steam quality
Recall: 𝑆′3 = 𝑆′𝑙3 + 𝑥(𝑆′𝑣3 − 𝑆′𝑙3 )
𝑆′ −𝑆′𝑙 6,5904−1,0753
𝑥 = (𝑆′3𝑣 −𝑆′3𝑙 ) = = 0,844
3 3 7,6132−1,0753
Maka
𝐻′3 = 𝐻′𝑙3 + 𝑥(𝐻′𝑣3 − 𝐻′𝑙3 ) = 334,9 + 0,844(2643,8 − 334,9) = 2283,6116
Recall: ∆𝐻𝑎𝑐𝑡𝑢𝑎𝑙 = 𝜂𝑡𝑢𝑟𝑏𝑖𝑛𝑒 . (∆𝐻)𝑠
(∆𝐻)𝑠 = 𝐻′3 − 𝐻2 = −1042,8884 (ΔH ideal)
∆𝐻𝑎𝑐𝑡𝑢𝑎𝑙 = 𝜂 . (∆𝐻)𝑠 = 75% − 1042,8884 = −782,1663 𝑘𝐽/𝑘𝑔
Recall: 𝑊𝑡𝑢𝑟𝑏𝑖𝑛 = 𝑚̇𝑠𝑡𝑒𝑎𝑚 . ∆𝐻𝑎𝑐𝑡𝑢𝑎𝑙
Wturbin = -107 J/s =-104kJ/s (Wturbin bertanda minus karena turbin menghasilkan kerja)
𝑊 −10𝑥103 𝑘𝐽/𝑠 𝑘𝑔
𝑚̇𝑠𝑡𝑒𝑎𝑚 = ∆𝐻𝑡𝑢𝑟𝑏𝑖𝑛 = −782,1663 𝑘𝐽/𝑘𝑔 = 12,785 … … (𝑖)
𝑎𝑐𝑡𝑢𝑎𝑙 𝑠

Tinjau Pompa(41)
Karena condenser beroperasi pada 80oC didapat properties steam masuk pompa
H4 = 334,9 kJ/kg ; V= 1,029 cm3/gr = 1,029 x 10-3 m3/kg; P = 47,36 kPa
(∆𝐻)𝑠
Recall: ∆𝐻𝑎𝑐𝑡𝑢𝑎𝑙 = 𝜂
𝑝𝑢𝑚𝑝

Tinjau kasus isentropic


(∆𝐻)𝑠 = 𝑉. Δ𝑃 = 1,029𝑥10−3 (8800 − 47,36) = 9,0065 𝑘𝐽/𝑘𝑔
(∆𝐻)𝑠 (∆𝐻)𝑠
∆𝐻𝑎𝑐𝑡𝑢𝑎𝑙 = 𝜂 𝐻1 − 𝐻4 = 𝜂
𝑝𝑢𝑚𝑝 𝑝𝑢𝑚𝑝
(∆𝐻)𝑠 9,0065
𝐻1 = 𝐻4 + 𝜂 = 334,9 + = 346,908 𝑘𝐽/𝑘𝑔
𝑝𝑢𝑚𝑝 75%

Tinjau Boiler
Neraca energy Boiler
𝑚̇𝑠𝑡𝑒𝑎𝑚 . (𝐻2 − 𝐻1 ) = 𝑛̇ 𝑔𝑎𝑠 . 𝑄̇𝐵𝑜𝑖𝑙𝑒𝑟
𝑚̇𝑠𝑡𝑒𝑎𝑚 . (𝐻2 − 𝐻1 )
𝑛̇ 𝑔𝑎𝑠 = … … (𝑖𝑖)
𝑄̇𝐵𝑜𝑖𝑙𝑒𝑟
𝐵𝑇𝑈 𝑘𝐽 𝑘𝐽
𝑄̇𝐵𝑜𝑖𝑙𝑒𝑟 = 𝐻𝑒𝑎𝑡𝑖𝑛𝑔 𝑉𝑎𝑙𝑢𝑒 = 1000 𝑠𝑐𝑓 𝑥1,055 𝐵𝑇𝑈 = 1055 𝑠𝑐𝑓 … … (𝑖𝑖𝑖)
𝑘𝐽 𝑘𝐽
Recall: 𝐻1 = 346,908 𝑘𝑔 𝐻2 = 3326,5 𝑘𝑔 … … (𝑖𝑣)
Substitusi (i) (iii) (iv) pada (ii)
12,785𝑥(3326,5−346,908)
𝑛̇ 𝑔𝑎𝑠 = = 36,11 𝑠𝑐𝑓/𝑠
1055
Konversi ke MMSCFD
𝑠𝑐𝑓 86400𝑠 𝑀𝑀𝑆𝐶𝐹
𝑛̇ 𝑔𝑎𝑠 = 36,11
𝑥 𝑥 = 3,12 𝑀𝑀𝑆𝐶𝐹𝐷
𝑠 𝑑𝑎𝑦 106 𝑠𝑐𝑓
4.Tentukan mole rate dan komposisi masing-masing stream pada gambar berikut. Assume
campuran mengikuti Hukum Raoult.
Solusi:
80oC, 110 kPa
Rate =?? mol/hr
{yi} = ?? Pada 80oC:
Rate: 20 mol/hr
80oC
135 kPa; 80oC  PsatA = 196kPa
110 kPa  PsatB = 98kPa
{zi}:
A= 45%  PsatC = 50kPa
Rate =?? mol/hr
B= 35%
{xi} = ??
C= 20%
80oC, 110 kPa
mol rate A: 45% x 20 = 9 mol/hr
mol rate B: 35% x 20 = 7 mol/hr
mol rate C: 20% x 20 = 4 mol/hr
Cek apakah sistem memiliki 2 fasa
𝑃𝑏𝑢𝑏𝑏𝑙𝑒 = ∑ 𝑥𝑖 𝑃1𝑠𝑎𝑡 = 45%. 196 + 35%. 98 + 20%. 50 = 132,5 𝑘𝑃𝑎
1 1
𝑃𝑑𝑒𝑤 = ∑ 𝑦 𝑃𝑠𝑎𝑡 = 45% 35% 20% = 101,3 𝑘𝑃𝑎
𝑖 1 ( + + )
196 98 50
Karena Pdew<Psistem<Pdew (101,3<110<132,5) maka sistem memiliki 2 fasa
Sistem 2 fasa  Recall Flash calculation
𝑃𝐴𝑠𝑎𝑡 196
𝐾𝐴 = = 110 = 1,782
𝑃
𝑃𝐵𝑠𝑎𝑡 98
𝐾𝐵 = = 110 = 0,891
𝑃
𝑃𝐶𝑠𝑎𝑡 50
𝐾𝐶 = = 110 = 0,455
𝑃
Recall
𝑧𝑖 𝐾𝑖
∑ 𝑦𝑖 = ∑ =1
1 + 𝑉(𝐾𝑖 − 1)
𝑃𝑏𝑢𝑏𝑏𝑙𝑒 −𝑃
Dengan trial and error hitung V dengan tebakan awal 𝑉 = 𝑃
𝑏𝑢𝑏𝑏𝑙𝑒 −𝑃𝑑𝑒𝑤
132,5 − 110
𝑉= = 0,72
132,5 − 101,3
Tebakan pertama
Untuk V= 0,72
0,45𝑥(1,782) 0,35𝑥(0,891) 0,2𝑥(0,455)
∑ 𝑦𝑖 = + 1+0,72(0,891−1) + 1+0,72(0,455−1) = 1,00121
1+0,72(1,782−1)
Tebakan kedua
Untuk V=0,735
0,45𝑥(1,782) 0,35𝑥(0,891) 0,2𝑥(0,455)
∑ 𝑦𝑖 = + 1+0,735(0,891−1) + 1+0,735(0,455−1) = 1,00004 ≈ 1
1+0,735(1,782−1)
Didapat V = 0,735
Jika anda ingin tahu bagaimana caranya mendapat nilai V tanpa nebak-nebak
gunakanlah SOLVER (Ask assistant for detail)
Komposisi gas {yi}
0,45𝑥(1,782)
𝑦1 = 1+0,735(1,782−1) = 0,51
0,35𝑥(0,891)
𝑦2 = 1+0,735(0,891−1) = 0,339
0,2𝑥(0,455)
𝑦3 = 1+0,735(0,455−1) = 0,1518
Komposisi liquid {xi}
𝑦
Recall: 𝑥𝑖 = 𝐾𝑖
𝑖
0,51
𝑥1 = 1,782 = 0,2862
0,339
𝑥2 = 0,891 = 0,3805
0,1518
𝑥3 = = 0,3336
0,455

Perhitungan mol rate


mol rate gas A= 0,51 x 9 mol/hr = 0,459 mol/hr
mol rate gas B= 0,339 x 7 mol/hr = 2,373 mol/hr
mol rate gas C= 0,1518 x 4 mol/hr = 0,6072 mol/hr
mol rate gas = V x mol rate inlet =0,735 x 20 mol/hr = 14,7 mol/hr
mol rate liquid A= 0,2862 x 9 mol/hr = 2,5758 mol/hr
mol rate liquid B= 0,3805 x 7 mol/hr = 2,6635 mol/hr
mol rate liquid C= 0,3336 x 4 mol/hr = 1,3344 mol/hr
mol rate liquid = L x mol rate inlet dimana L fraksi liquid pada kondisi akhir
L = (1-V) = 1-0,735 = 0,265
mol rate liquid = 0,265 x 20 mol/hr = 5,3 mol/hr
Soal Bonus: Jelaskan aplikasi fugasitas di teknik perminyakan (nantinya untuk
menghitung apa? Menyelesaikan persoalan apa?)
Jawab:
Dalam termodinamika kimia, fugacity (f) dari gas nyata adalah tekanan efektif yang
menggantikan tekanan mekanis dalam perhitungan kesetimbangan kimia. Perhitungan
akurat dari kesetimbangan kimia untuk gas nyata harus menggunakan fugacity. Dalam
dunia perminyakan fugacity digunakan untuk menyelesaikan persoalan penentuan
tekanan pengoperasian alat seperti separator, turbin dan lain-lain..
TK 3081-Termodika Dasar A
UAS 2010/2011
1. Dari eksperimen diperoleh bahwa entalpi larutan A/B mengikuti persamaan H = 400x A
+ 600xB +xAxB(40xA+20xB) dimana x adalah fraksi mold an H dalam J/mol. Tentukan
entalpi parsial zat A (H̅A) pada larutan hasil pencampuran 300cc A dan 200 cc B.
Densitas A = 0,8 gr/cc B = 1,2 gr/cc. Berat molekul: A = 48 gram/mol, B = 32 gram/mol
2. Show that ideal gas mixing at constant temperature is an irreversible process Hint: Start
𝑑𝑇 𝜕𝑉
with property relation of entropy 𝑑𝑆 = 𝐶𝑝 − (𝜕𝑇 ) 𝑑𝑃, apply generic partial
𝑇 𝑃
property equation: M̅iig (T,P) = Miig (T,P) dan summability relation.
3. Suatu power plant siklus Rankine beroperasi dengan kondisi berikut:
Turbine power: 975 kJ/kg steam
Kerja Pompa: 8,86 kJ/kg steam
Condenser load: 2000 kJ/kg steam
Tekanan condenser: 100 kPa
Proses: Isentropic
Asumsi: boiler process = constant pressure
Tentukan:
(a) efisiensi siklus
(b) jika daya tahan material boiler = 600oC, 100 bar tentukan apakah power plant
tersebut aman
4. Tinjau kasus flash berikut:

Vapor  PsatA = 144,76 kPa


 PsatB = 70,37 kPa
T= 80oC
 PsatC = 34,80 kPa
yA= 0,5
ZA= 0,4 yB = 0,3
ZB= 0,2 yC = 0,2
Tentukan P sistem dan komposisi
ZC= 0,4 fasa cair. Assume vapor phase ideal
gas. Liquid phase ideal solution
liquid
SOLUSI
TK 3081-Termodika Dasar A
UAS 2010/2011
1.Dari eksperimen diperoleh bahwa entalpi larutan A/B mengikuti persamaan H = 400x A
+ 600xB +xAxB(40xA+20xB) dimana x adalah fraksi mold an H dalam J/mol. Tentukan
entalpi parsial zat A (H̅A) pada larutan hasil pencampuran 300cc A dan 200 cc B. Densitas
A = 0,8 gr/cc B = 1,2 gr/cc. Berat molekul: A = 48 gram/mol, B = 32 gram/mol
Solusi:
H = 400xA + 600xB +xAxB(40xA+20xB)
Replace xB by 1-xA in the given equation for H and simplify:
H = 600 -180xA -20xA3
Whence,
𝑑𝐻
= −180 − 60𝑥𝐴2
𝑑𝑥𝐴
Recall: 𝑀̅1 = 𝑀 + 𝑥2 𝑑𝑀
𝑑𝑥1
𝑑𝐻
̅𝐴 = 𝐻 + (1 − 𝑥𝐴 )
𝐻 𝑑𝑥 𝐴
̅𝐴 = 600 − 180𝑥𝐴 − 20𝑥𝐴3 + (1 − 𝑥𝐴 )(−180 − 60𝑥𝐴2 )
𝐻
̅𝐴 = 420 − 60𝑥𝐴 2 + 40𝑥𝐴3 … … (𝑖)
𝐻
̅2 = 𝑀 − 𝑥1 𝑑𝑀
Recall: 𝑀 𝑑𝑥1
𝑑𝐻
̅𝐵 = 𝐻 − 𝑥𝐴
𝐻 𝑑𝑥 𝐴
̅𝐵 = 600 − 180𝑥𝐴 − 20𝑥𝐴3 − 𝑥𝐴 (−180 − 60𝑥𝐴2 )
𝐻
̅𝐵 = 600 + 40𝑥𝐴3 … … (𝑖𝑖)
𝐻
We need x2
𝑚 𝑉𝐴 𝜌𝐴 300𝑥0,8
𝑛𝐴 = 𝐵𝑀𝐴 = = = 5 𝑚𝑜𝑙
𝐴 𝐵𝑀𝐴 48
𝑚 𝑉𝐵 𝜌𝐵 200𝑥1,2
𝑛𝐵 = 𝐵𝑀𝐵 = = = 7,5 𝑚𝑜𝑙
𝐵 𝐵𝑀𝐵 32
𝑛𝑡𝑜𝑡𝑎𝑙 = 𝑛𝐴 + 𝑛𝐵 = 5 + 7,5 = 12,5
𝑛𝐴 5
𝑥𝐴 = 𝑛 = 12,5 = 0,4 … … (𝑖𝑖𝑖)
𝑡𝑜𝑡𝑎𝑙
Substitusi (iii) pada (i) dan (ii)
𝐻̅𝐴 = 420 − 60(0,4)2 + 40(0,4)3 = 412,96 𝐽/𝑚𝑜𝑙
𝐻̅𝐵 = 600 + 40(0,4)3 = 602,56 𝐿/𝑚𝑜𝑙

Read: Introduction to Chemical Engineering Thermodynamics 7th ed (J.M Smith, Van N


ess, Abbott) example 11.4
2.Show that ideal gas mixing at constant temperature is an irreversible process Hint: Start
𝑑𝑇 𝜕𝑉
with property relation of entropy𝑑𝑆 = 𝐶𝑝 − (𝜕𝑇 ) 𝑑𝑃, apply generic partial property
𝑇 𝑃
equation: M̅iig (T,P) = Miig (T,P) dan summability relation.
Solusi:
We need these relations
- Irreversible process  ΔS=0
- Gibb’s theorem  𝑀 ̅𝑖𝑖𝑔 (𝑇, 𝑃) = 𝑀𝑖𝑖𝑔 (𝑇, 𝑃𝑖 )
- Summability relation  𝑀 = ∑𝑖 𝑥𝑖 𝑀 ̅𝑖
𝑑𝑇 𝜕𝑉
Start: 𝑑𝑆 = 𝐶𝑝 − (𝜕𝑇 ) 𝑑𝑃
𝑇 𝑃
𝜕𝑉
Untuk kasus isothermal dT=0  𝑑𝑆 = − ( ) 𝑑𝑃
𝜕𝑇 𝑃
Recall ideal gas equation P.V=R.T
𝜕𝑉 𝑅
V= R.T/P  (𝜕𝑇 ) = 𝑃
𝑃
Maka
𝑖𝑔 𝑅
𝑑𝑆𝑖 = − ( ) 𝑑𝑃
𝑃
Integrasi
𝑃 𝑖𝑔 𝑃 𝑅 𝑃
∫𝑃 𝑑𝑆𝑖 = ∫𝑃 − (𝑃) 𝑑𝑃 = −𝑅 ln 𝑃
𝑖 𝑖 𝑖
1 𝑃
Recall partial properties Pi= xi P  =𝑃
𝑥𝑖 𝑖
𝑃 𝑖𝑔 𝑖𝑔 𝑖𝑔
∫𝑃 𝑑𝑆𝑖 = 𝑆𝑖 (𝑇, 𝑃) − 𝑆𝑖 (𝑇, 𝑃𝑖 )
𝑖
Substitusi
𝑃 𝑖𝑔 𝑃 𝑅 𝑃
∫𝑃 𝑑𝑆𝑖 = ∫𝑃 − (𝑃) 𝑑𝑃 = −𝑅 ln 𝑃
𝑖 𝑖 𝑖
𝑖𝑔 𝑖𝑔 1
𝑆𝑖 (𝑇, 𝑃) − 𝑆𝑖 (𝑇, 𝑃𝑖 ) = −𝑅 ln 𝑥 = 𝑅 ln 𝑥𝑖
𝑖
𝑖𝑔 𝑖𝑔
𝑆𝑖 (𝑇, 𝑃𝑖 ) = 𝑆𝑖 (𝑇, 𝑃) − 𝑅 ln 𝑥𝑖
Recall Gibb’s Theorem ̅𝑖𝑖𝑔 (𝑇, 𝑃) = 𝑀𝑖𝑖𝑔 (𝑇, 𝑃𝑖 )
𝑀
𝑖𝑔 𝑖𝑔
Maka 𝑆 (𝑇, 𝑃𝑖 ) = 𝑆̅ (𝑇, 𝑃)
𝑖 𝑖
Substitusi
𝑖𝑔 𝑖𝑔
𝑆𝑖̅ (𝑇, 𝑃) = 𝑆𝑖 (𝑇, 𝑃) − 𝑅 ln 𝑥𝑖
𝑖𝑔 𝑖𝑔
𝑆𝑖̅ = 𝑆𝑖 − 𝑅 ln 𝑥𝑖
Recall Summability relation  𝑀 = ∑𝑖 𝑥𝑖 𝑀 ̅𝑖
𝑖𝑔 𝑖𝑔
Maka: 𝑆𝑖 = ∑𝑖 𝑥𝑖 𝑆𝑖̅
Substitusi
𝑖𝑔 𝑖𝑔
𝑆𝑖 = ∑𝑖 𝑥𝑖 (𝑆𝑖 − 𝑅 ln 𝑥𝑖 )
𝑖𝑔 𝑖𝑔
𝑆𝑖 = ∑𝑖 𝑥𝑖 𝑆𝑖 − ∑𝑖 𝑥𝑖 (𝑅 ln 𝑥𝑖 )
𝑖𝑔 𝑖𝑔
𝑆𝑖 − ∑𝑖 𝑥𝑖 𝑆𝑖 = − ∑𝑖 𝑥𝑖 (𝑅 ln 𝑥𝑖 )
𝑖𝑔
∆𝑆𝑖 (𝑚𝑖𝑥𝑖𝑛𝑔) = −𝑅 ∑𝑖 𝑥𝑖 ln 𝑥𝑖
𝑖𝑔 1
∴ ∆𝑆𝑖 (𝑚𝑖𝑥𝑖𝑛𝑔) = 𝑅 ∑ 𝑥𝑖 ln
𝑥𝑖
𝑖
Karena nilai R > 0, dan xi < 1 maka ln 1/xi berharga + (positif) sehingga dapat
𝑖𝑔
disimpulkan ∆𝑆𝑖 (𝑚𝑖𝑥𝑖𝑛𝑔) > 0

3.Suatu power plant siklus Rankine beroperasi dengan kondisi berikut:


Turbine power: 975 kJ/kg steam
Kerja Pompa: 8,86 kJ/kg steam
Condenser load: 2000 kJ/kg steam
Tekanan condenser: 100 kPa
Proses: Isentropic
Asumsi: boiler process = constant pressure
Tentukan:
(a) Efisiensi siklus
(b) Jika daya tahan material boiler = 600oC, 100 bar tentukan apakah power plant tersebut
aman Constant Pressure Isentropic
Solusi: 1 process
2

Wturbine =975
kJ/kg steam
Wpump = 8,86
kJ/kg steam
4 3
Condenser
Condenser load =
100 kPa
2000 kJ/kg steam
(a) Efisiensi siklus
|𝑊̇𝑐𝑦𝑐𝑙𝑒 | |𝑊̇𝑡𝑢𝑟𝑏𝑖𝑛 + 𝑊̇𝑝𝑢𝑚𝑝 |
𝜂𝑐𝑦𝑐𝑙𝑒 = 𝑥100% = 𝑥100% … … (𝑖)
𝑄𝐵𝑜𝑖𝑙𝑒𝑟 𝑄̇𝐵𝑜𝑖𝑙𝑒𝑟
Recall: 𝑊̇𝑐𝑦𝑐𝑙𝑒 = 𝑊̇𝑡𝑢𝑟𝑏𝑖𝑛 + 𝑊̇𝑝𝑢𝑚𝑝 = −(𝑄̇𝐵𝑜𝑖𝑙𝑒𝑟 + 𝑄̇𝐶𝑜𝑛𝑑𝑒𝑛𝑠𝑒𝑟 )
𝑄̇𝐵𝑜𝑖𝑙𝑒𝑟 = −(𝑊̇𝑡𝑢𝑟𝑏𝑖𝑛 + 𝑊̇𝑝𝑢𝑚𝑝 + 𝑄̇𝐶𝑜𝑛𝑑𝑒𝑛𝑠𝑒𝑟 )
𝑘𝐽
𝑄̇𝐵𝑜𝑖𝑙𝑒𝑟 = −(−975 + 8,86 + (−2000)) = 2966,14 𝑘𝑔 … . . (𝑖𝑖)
Note: Wturbin dan Qcondenser bernilai minus karena melepas energy keluar sistem
Substitusi (ii) ke (i)
|−975 + 8,86|
𝜂𝑐𝑦𝑐𝑙𝑒 = 𝑥100% = 32,57 %
2966,14
(b) Syarat aman Boiler
P= 100 bar = 10000 kPa
T= 600oC
at P=10000 kPa; T= 600oC properties of superheated steam:
H2= 3622,7 kJ/kg (steam table)

Tinjau turbin (23)


Wturbin = H3-H2  H3= Wturbin + H2

Tinjau condenser (34)


Qcondenser = H4-H3  Qcondenser = H4 – (Wturbin + H2)
H4 = (Wturbin + H2 + Qcondenser)

Tinjau pompa (41)


Wpompa = H4-H1  H1= H4 - Wpompa
H1= (Wturbin + H2 + Qcondenser)- Wpompa
H1= (-975) + 3622,7 +(-2000)-8,86 = 638,84 kJ/kg

Tinjau Boiler (12)


𝑘𝐽
Recall 𝑄𝐵𝑜𝑖𝑙𝑒𝑟 = 2966,14 𝑘𝑔
Batas ketahanan material boiler = H2 – H1 = 3622,7-638,84= 2983,86 kJ/kg
Karena Δ𝐻𝑏𝑜𝑖𝑙𝑒𝑟 > 𝑄𝐵𝑜𝑖𝑙𝑒𝑟 maka Power plant aman

4.Tinjau kasus flash berikut:

Vapor  PsatA = 144,76 kPa


 PsatB = 70,37 kPa
T= 80oC
 PsatC = 34,80 kPa
yA= 0,5
ZA= 0,4 yB = 0,3
ZB= 0,2 yC = 0,2
Tentukan P sistem dan komposisi
ZC= 0,4 fasa cair. Assume vapor phase ideal
gas. Liquid phase ideal solution
liquid
(a) Psistem

Sistem 3 komponen zat A,B,C pada T=80oC

 PsatA = 144,76 kPa


 PsatB = 70,37 kPa
 PsatC = 34,80 kPa
Tentukan Psistem dan komposisi liquid
Recall Raoult’s law: 𝑦𝑖 𝑃𝑠𝑖𝑠𝑡𝑒𝑚 = 𝑥𝑖 𝑃𝑖𝑠𝑎𝑡 ,
𝑦𝑖
Cari tekanan yang membuat ∑ 𝑥𝑖 = 1 maka ∑ 𝑃𝑠𝑎𝑡 𝑃𝑠𝑖𝑠𝑡𝑒𝑚 = ∑ 𝑥𝑖
𝑖

1
𝑃𝑠𝑖𝑠𝑡𝑒𝑚 =
∑ 𝑦𝑖 /𝑃𝑖𝑠𝑎𝑡

1 1 1
𝑃𝑠𝑖𝑠𝑡𝑒𝑚 = + + = 74,26 𝑘𝑃𝑎
0,5/144,76 0,3/70,37 0,2/34,80

(b) komposisi liquid


𝑦𝑖 𝑃𝑠𝑖𝑠𝑡𝑒𝑚
Recall 𝑥𝑖 = 𝑃𝑖𝑠𝑎𝑡

𝑦𝐴 𝑃𝑠𝑖𝑠𝑡𝑒𝑚 0,5𝑥74,26
𝑥𝐴 = = = 0,2565
𝑃𝐴𝑠𝑎𝑡 144,76

𝑦𝐵 𝑃𝑠𝑖𝑠𝑡𝑒𝑚 0,3𝑥74,26
𝑥𝐵 = = = 0,3166
𝑃𝐵𝑠𝑎𝑡 70,37

𝑦𝐶 𝑃𝑠𝑖𝑠𝑡𝑒𝑚 0,2𝑥74,26
𝑥𝐶 = = = 0,4268
𝑃𝐶𝑠𝑎𝑡 34,80
TK 3081-Termodika Dasar A
Perbaikan I Modul II 2010/2011

1. Tinjau suatu electric power plant siklus Rankine berbahan bakar gas bumi. Steam
masuk turbin pada 8,6 Mpa, 500oC. Steam keluar turbin masuk ke condenser pada 10
kPa. Efisiensi turbin 75%, efisiensi generator 90%, efisiensi pompa 75%, efisiensi
electric motor penggerak pompa 90%. Net output dari power cycle 100 MWe. Heating
value gas bumi 1000 BTU/SCF. (a) Tentukan konsumsi gas dalam (MMSCFD). (b)
Listrik yang dihasilkan dijual 0,06US$/kWh, tentukan harga gas maksimum
(US$/MMBTU) agar produsen listrik tidak rugi. Note : MWe = Mega Watt electricity.
SOLUSI
TK 3081-Termodika Dasar A
Perbaikan I Modul II 2010/2011

1.Tinjau suatu electric power plant siklus Rankine berbahan bakar gas bumi. Steam masuk
turbin pada 8,6 Mpa, 500oC. Steam keluar turbin masuk ke condenser pada 10 kPa.
Efisiensi turbin 75%, efisiensi generator 90%, efisiensi pompa 75%, efisiensi electric
motor penggerak pompa 90%. Net output dari power cycle 100 MWe. Heating value gas
bumi 1000 BTU/SCF. (a) Tentukan konsumsi gas dalam (MMSCFD). (b) Listrik yang
dihasilkan dijual 0,06US$/kWh, tentukan harga gas maksimum (US$/MMBTU) agar
produsen listrik tidak rugi. Note : MWe = Mega Watt electricity.
Solusi:

8,6 MPa, 500oC


1 2 Net output
100 MWe

Heat Val: 1000


75% 90 %
75 % BTU/scf

10 kPa

4 3
Qc Harga jual listrik =
0,06 US$/kWh
Tinjau Turbin (23)
Keadaan 2 (8,6 MPa=8600 kPa, 500oC)
H2= 3391,6 kJ/kg ; S2= 6,6858 kJ/kg.K (dari steam table superheated steam)
Keadaan 3 (10 kPa)
Tinjau keadaan isentropic S2=S‘3 =6,6858 kJ/kg.K
Cek apakah sistem 2 fasa
Pada steam table tidak ada data steam pada 10 kPa sehingga gunakan interpolasi
10,09−10 10−9,582
𝑆3𝑙′ = (10,09−9,582) 0,6383 + (10,09−9,582) 0,6514 = 0,6491 𝑘𝐽/𝑘𝑔. 𝐾
10,09−10 10−9,582
𝑆3𝑣′ = (10,09−9,582) 8,1661 + (10,09−9,582) 8,1481 = 8,1513 𝑘𝐽/𝑘𝑔. 𝐾
10,09−10 10−9,582
𝐻3𝑙′ = (10,09−9,582) 188,4 + (10,09−9,582) 192,5 = 191,8 𝑘𝐽/𝑘𝑔
10,09−10 10−9,582
𝐻3𝑣′ = ( ) 2583,3 + ( ) 2585,1 = 2584,8 𝑘𝐽/𝑘𝑔
10,09−9,582 10,09−9,582
Karena Sl’3 < S‘3 < Sv’3 maka steam keluar turbin memiliki 2 fasa
Perhitungan steam quality
′ ′ 𝑆3′ −𝑆3𝑙′
Recall 𝑆3′ = 𝑆3𝑙′ + 𝑥(𝑆3𝑣 − 𝑆3𝑙 )  𝑥= ′ ′
(𝑆3𝑣 −𝑆3𝑙 )
𝑆3′ −𝑆3𝑙′ 6,6858−0,6491
𝑥= ′ ′ = 8,1513−0,6491 = 0,80
(𝑆3𝑣 −𝑆3𝑙 )
′ ′
𝐻3′ = 𝐻3𝑙′ + 𝑥(𝐻3𝑣 − 𝐻3𝑙 ) = 191,8 + 0,8(2584,8 − 191,8) = 2106,2 𝑘𝐽/𝑘𝑔
∆𝐻𝑖𝑠𝑒𝑛𝑡𝑟𝑜𝑝𝑖𝑐 = 𝐻3′ − 𝐻2 = 2106,2 − 3391,6 = −1285,4 𝑘𝐽/𝑘𝑔
Recall 𝑊̇𝑡𝑢𝑟𝑏𝑖𝑛 = ∆𝐻𝑎𝑐𝑡𝑢𝑎𝑙 = ∆𝐻𝑖𝑠𝑒𝑛𝑡𝑟𝑜𝑝𝑖𝑐 𝑥𝜂𝑡𝑢𝑟𝑏𝑖𝑛 𝑥𝜂𝑔𝑒𝑛𝑒𝑟𝑎𝑡𝑜𝑟
𝑘𝐽
∆𝐻𝑎𝑐𝑡𝑢𝑎𝑙 = −1285,4𝑥0,75𝑥0,9 = −867,645 𝑘𝑔 … … (𝑖)

Tinjau Pompa (41)


Keadaan 4 (10 kPa saturated liquid)
H4= 191,8 kJ/kg
V = 1,01 cm3/g = 1,01 x 10-3 m3/kg ( interpolasi steam table)
Tinjau keadaan isentropic
∆𝐻𝑖𝑠𝑒𝑛𝑡𝑟𝑜𝑝𝑖𝑐 = 𝑉. ∆𝑃 = 1,01𝑥10−3 𝑥(8600 − 10) = 8,6759 𝑘𝐽/𝑘𝑔
∆𝐻
Recall 𝑊̇𝑝𝑢𝑚𝑝 = ∆𝐻𝑎𝑐𝑡𝑢𝑎𝑙 = 𝑖𝑠𝑒𝑛𝑡𝑟𝑜𝑝𝑖𝑐
𝜂𝑝𝑢𝑚𝑝
8,6759 𝑘𝐽
∆𝐻𝑎𝑐𝑡𝑢𝑎𝑙 = = 11,568 𝑘𝑔 … … (𝑖𝑖)
0,75
∆𝐻𝑎𝑐𝑡𝑢𝑎𝑙 = 𝐻1 − 𝐻4  𝐻1 = 𝐻4 + ∆𝐻𝑎𝑐𝑡𝑢𝑎𝑙
𝐻1 = 191,8 + 11,568 = 203,368 𝑘𝐽/𝑘𝑔

Tinjau Boiler (12)


(a) Energy balance Boiler
𝑚̇𝑠𝑡𝑒𝑎𝑚 . (𝐻2 − 𝐻1 ) = 𝑛̇ 𝑔𝑎𝑠 . 𝑄̇
𝑚̇𝑠𝑡𝑒𝑎𝑚 . (𝐻2 − 𝐻1 )
𝑛̇ 𝑔𝑎𝑠 = … … (𝑖𝑖𝑖)
𝑄̇
𝐵𝑇𝑈 𝑘𝐽 𝑘𝐽
𝑄̇ = ℎ𝑒𝑎𝑡𝑖𝑛𝑔 𝑣𝑎𝑙𝑢𝑒 = 1000 𝑠𝑐𝑓 𝑥1,055 𝐵𝑇𝑈 = 1055 𝑠𝑐𝑓 … … (𝑖𝑣)
Recall 𝑁𝑒𝑡 𝑜𝑢𝑡𝑝𝑢𝑡 𝑒𝑙𝑒𝑐𝑡𝑟𝑖𝑐𝑖𝑡𝑦 = 𝑚̇𝑠𝑡𝑒𝑎𝑚 𝑥(𝑊̇𝑡𝑢𝑟𝑏𝑖𝑛 + 𝑊̇𝑝𝑢𝑚𝑝 )
𝑁𝑒𝑡 𝑜𝑢𝑡𝑝𝑢𝑡 𝑒𝑙𝑒𝑐𝑡𝑟𝑖𝑐𝑖𝑡𝑦
𝑚̇𝑠𝑡𝑒𝑎𝑚 = (𝑣)
(𝑊̇𝑡𝑢𝑟𝑏𝑖𝑛 + 𝑊̇𝑝𝑢𝑚𝑝 )
Net output electricity = -100 MWe= -100 x 103 kW = -100 x 103 kJ/s ……(vi)
Substitusi (i) (ii) (vi) ke (v)
−100 𝑥 103 𝑘𝑔
𝑚̇𝑠𝑡𝑒𝑎𝑚 = = 116,8 … … (𝑣𝑖𝑖)
(−867,645 + 11,568) 𝑠
Recall H2= 3391,6 kJ/kg H1= 203,368 kJ/kg (viii)
Substitusi (iv) (vii) (viii) ke (iii)
116,8𝑥(3391,6 − 203,368) 𝑠𝑐𝑓
𝑛̇ 𝑔𝑎𝑠 = = 352,972
1055 𝑠
Konversi ke MMSCFD
𝑠𝑐𝑓 𝑠 𝑀𝑀𝑀𝑆𝐶𝐹
𝑛̇ 𝑔𝑎𝑠 = 352,972 𝑥86400 𝑥 = 30,50 𝑀𝑀𝑆𝐶𝐹𝐷
𝑠 𝑑𝑎𝑦 106 𝑠𝑐𝑓
(b)Tentukan harga gas maksimum agar produsen tidak rugi!
Harga gas maksimum agar tidak rugi dicapai saat Break Even Point (BPE)
(𝑘𝑜𝑛𝑠𝑢𝑚𝑠𝑖 𝑔𝑎𝑠)(ℎ𝑎𝑟𝑔𝑎 𝑔𝑎𝑠) = (𝑒𝑙𝑒𝑐𝑡𝑟𝑖𝑐𝑖𝑡𝑦 𝑜𝑢𝑡𝑝𝑢𝑡)(ℎ𝑎𝑟𝑔𝑎 𝑗𝑢𝑎𝑙 𝑙𝑖𝑠𝑡𝑟𝑖𝑘)
(𝑒𝑙𝑒𝑐𝑡𝑟𝑖𝑐𝑖𝑡𝑦 𝑜𝑢𝑡𝑝𝑢𝑡)(ℎ𝑎𝑟𝑔𝑎 𝑗𝑢𝑎𝑙 𝑙𝑖𝑠𝑡𝑟𝑖𝑘)
(ℎ𝑎𝑟𝑔𝑎 𝑔𝑎𝑠) = … … (𝑖)
(𝑘𝑜𝑛𝑠𝑢𝑚𝑠𝑖 𝑔𝑎𝑠)
Net output electricity = 100 MWe
Basis 1 jam  100 MWh = 100.000 kWh ……(ii)
Perlu dicari Konsumsi gas per jam dalam MMBTU
(𝑘𝑜𝑛𝑠𝑢𝑚𝑠𝑖 𝑔𝑎𝑠) = 𝑛̇ 𝑔𝑎𝑠 𝑥𝐻𝑒𝑎𝑡𝑖𝑛𝑔 𝑣𝑎𝑙𝑢𝑒
𝑀𝑀𝑆𝐶𝐹 𝑀𝑀𝐵𝑇𝑈 𝑑𝑎𝑦
(𝑘𝑜𝑛𝑠𝑢𝑚𝑠𝑖 𝑔𝑎𝑠) = 30,5 𝑥1000 𝑀𝑀𝑆𝐶𝐹 𝑥 24 ℎ𝑟 = 1270,83 𝑀𝑀𝐵𝑇𝑈 … … (𝑖𝑖𝑖)
𝑑𝑎𝑦
Substitusi (ii) (iii) ke (i)
100.000 𝑘𝑊ℎ 𝑥 0,06 𝑈𝑆$/𝑘𝑊ℎ
(ℎ𝑎𝑟𝑔𝑎 𝑔𝑎𝑠) = = 4,7213 𝑈𝑆$/𝑀𝑀𝐵𝑇𝑈
1270,83𝑀𝑀𝐵𝑇𝑈
TK 3081-Termodika Dasar A
UAS 2012/2013

1. Tinjau suatu mesin siklus Rankine dengan fluida kerja steam dilengkapi dengan
superheater dan reheater. Steam keluar superheater pada 8 Mpa 475oC, masuk reheater
pada 0,7 MPa dan keluar reheater pada 0,7 MPa, 450oC. Kondenser beroperasi pada 10
kPa. Power output turbin 100 MW. Air pendingin masuk 20oC, keluar 60oC. Tentukan
input kalor (MW) dan laju massa air pendingin (kg/s). Cp air = 4,18 kJ/kg.oC
2. Suatu gas mengikuti model P(V-b) = RT dimana b konstanta positif. Turunkan
persamaan Joule-Thompson coefficient gas tersebut. Dapatkah gas tersebut
didinginkan melalui throttling?

𝜕𝐻 𝜕𝐻
Mulai dengan: 𝑑𝐻 = ( 𝜕𝑇 ) 𝑑𝑇 + ( 𝜕𝑇 ) 𝑑𝑃 dan 𝑑𝐻 = 𝑇 𝑑𝑆 + 𝑉 𝑑𝑃
𝑃 𝑇
3. Suatu vapor-compression refrigerator digunakan untuk mendinginkan natural gas
200MSCFD dari 140oF menjadi 40oF. Refrigerant HFC-134a, tekanan operasi:
evaporator 3 psia, condenser 80 psia, efisiensi compressor 66%. Tentukan (a) kerja
compressor (hp) dan (b) COP. Natural gas: Cp = 0,575 Btu/lbm.oF, BM = 19 lbm/lbmol
4. Campuran dengan komposisi (molar): A = 45%, B= 35% dan C= 20% sebanyak 20
mol dalam piston-silinder diekspansi menjadi 80 kPa, 70oC. Relasi Psat vs temperature
masing-masing zat mengikuti model Antoine berikut:
2940 2945 2972
ln 𝑃 𝑠𝑎𝑡𝐴 = 14,5 − 𝑡+237 ln 𝑃 𝑠𝑎𝑡 𝐵 = 14,3 − 𝑡+224 ln 𝑃 𝑠𝑎𝑡 𝐶 = 14,2 − 𝑡+209
(Psat dalam kPa dan t dalam oC)

Anggap sistem berkelakuan mengikuti Hukum Raoult.


(a) Tunjukkan bahwa pada kondisi akhir ekspansi, campuran tersebut berupa 2 fasa
(gas-cair).
(b) Tentukan banyaknya fasa gas (mol) pada kondisi akhir ekspansi.
Soal Bonus: Jelaskan mengapa steam turbine dirancang untuk beroperasi pada kondisi
Superheated. Gunakan skematik diagram TS untuk membantu memperjelas jawaban
pertanyaan ini
SOLUSI
TK 3081-Termodika Dasar A
UAS 2012/2013

1.Tinjau suatu mesin siklus Rankine dengan fluida kerja steam dilengkapi dengan
superheater dan reheater. Steam keluar superheater pada 8 Mpa 475 oC, masuk reheater
pada 0,7 MPa dan keluar reheater pada 0,7 MPa, 450oC. Kondenser beroperasi pada 10
kPa. Power output turbin 100 MW. Air pendingin masuk 20oC, keluar 60oC. Tentukan
input kalor (MW) dan laju massa air pendingin (kg/s). Cp air = 4,18 kJ/kg.oC
Solusi: o
0,7 Mpa 450 C

0,7 Mpa
Qin =??

100 MW

Cooling water out 60oC


2 5 Cp water: 4,18 kJ/kg.K
o
8 Mpa 475 C

10 kPa

1
6 Cooling water in
20oC ṁwater =??
(a) Qinput
Recall:
𝑄̇𝑖𝑛𝑝𝑢𝑡 = 𝑚̇𝑠𝑡𝑒𝑎𝑚 𝑥[(𝐻2 − 𝐻1 ) − (𝐻4 − 𝐻3 )] … … (𝑖)
Tinjau turbin pertama (23)
Keadaan 2 (8MPa = 8000 kPa, 475oC)
H2= 3337,2 kJ/kg S2=6,6452 kJ/kg.K (steam table superheated steam)
Karena data efisiensi tidak diberikan Asumsi turbin dalam keadaan ideal (isentropic)
S2=S3=6,6452 kJ/kg.K
Steam masuk reheater pada 0,7 MPa maka didapat properties steam keluar turbin
S3l= 1,9918 ;S3v=6,7052 ;H3l= 697,061 ; H3v= 2762 (steam table superheated steam)
Karena S3l < S3< S3v maka steam keluar turbin memiliki 2 fasa
Find steam quality
Recall: 𝑆3 = 𝑆3𝑙 + 𝑥(𝑆3𝑣 − 𝑆3𝑙 )
𝑆 −𝑆 𝑙 6,6452−1,9918
𝑥 = (𝑆3𝑣−𝑆3𝑙 ) = 6,7052−1,9918 = 0,9873
3 3
Maka

𝐻3 = 𝐻3𝑙 + 𝑥(𝐻3𝑣 − 𝐻3𝑙 ) = 697,061 + 0,9873(2762 − 697,061)


𝑘𝐽
𝐻3 = 2735,78 … … (𝑖𝑖)
𝑘𝑔
Tinjau turbin (45)
Keadaan 4 (0,7 MPA=700 kPa, 450oC)
H4 = 3374,7 ; S4= 7,7875 (steam table superheated steam)
Karena data efisiensi tidak diberikan Asumsi turbin dalam keadaan ideal (isentropic)
S4=S5=7,7875 kJ/kg.K
Condenser beroperasi pada 10 kPa maka didapat properties steam keluar turbin
S5l= 0,6493 ;S5v=8,1511 ;H5l=191,832 ; H5v= 2584,8 (steam table superheated steam)
Karena S5l < S5< S5v maka steam keluar turbin memiliki 2 fasa
Find steam quality
Recall: 𝑆5 = 𝑆5𝑙 + 𝑥(𝑆5𝑣 − 𝑆5𝑙 )
𝑆 −𝑆 𝑙 7,7875−0,6493
𝑥 = (𝑆5𝑣−𝑆5𝑙 ) = 8,1511−0,6493 = 0,9515
5 5
Maka

𝐻5 = 𝐻5𝑙 + 𝑥(𝐻5𝑣 − 𝐻5𝑙 ) = 191,832 + 0,9515(2584,8 − 191,832)


𝑘𝐽
𝐻5 = 2468,741
𝑘𝑔
Recall: 𝑊̇𝑜𝑢𝑡𝑝𝑢𝑡 𝑡𝑢𝑟𝑏𝑖𝑛 = 𝑚̇𝑠𝑡𝑒𝑎𝑚 𝑥[(𝐻3 − 𝐻2 ) + (𝐻5 − 𝐻4 )]
𝑊̇𝑜𝑢𝑡𝑝𝑢𝑡 𝑡𝑢𝑟𝑏𝑖𝑛
𝑚̇𝑠𝑡𝑒𝑎𝑚 =
[(𝐻3 − 𝐻2 ) + (𝐻5 − 𝐻4 )]
Plug in numbers
−100𝑥103 𝑘𝐽/𝑠
𝑚̇𝑠𝑡𝑒𝑎𝑚 =
[(2735,78 − 3337,2) + (2468,741 − 3374,7)]𝑘𝐽/𝑘𝑔
𝑘𝑔
𝑚̇𝑠𝑡𝑒𝑎𝑚 = 66,34 … … (𝑖𝑖𝑖)
𝑠
Tinjau Pompa (61)
Keadaan 6 (10 kPa saturated liquid)
H6= 191,832 kJ/kg
V = 1,01 cm3/g = 1,01 x 10-3 m3/kg
Karena data efisiensi tidak diberikan Asumsi pompa dalam keadaan ideal (isentropic)
∆𝐻𝑖𝑠𝑒𝑛𝑡𝑟𝑜𝑝𝑖𝑐 = 𝑉. ∆𝑃 = 1,01𝑥10−3 𝑥(8000 − 10) = 8,0699 𝑘𝐽/𝑘𝑔
∆𝐻𝑖𝑠𝑒𝑛𝑡𝑟𝑜𝑝𝑖𝑐 = 𝐻1 − 𝐻6  𝐻1 = 𝐻6 + ∆𝐻𝑖𝑠𝑒𝑛𝑡𝑟𝑜𝑝𝑖𝑐
𝑘𝐽
𝐻1 = 191,832 + 8,0699 = 199,9019 … … (𝑖𝑣)
𝑘𝑔
Recall H2= 3337,2 kJ/kg ;H4 = 3374,7 kJ/kg ……(v)
Substitusi (ii) (iii) (iv) (v) ke (i)
𝑄̇𝑖𝑛𝑝𝑢𝑡 = 66,34[(3337,2 − 199,9019) + (3374,7 − 2735,78)]
𝑘𝐽
𝑄̇𝑖𝑛𝑝𝑢𝑡 = 250514,31 = 250,514 𝑀𝑊
𝑠
(b) Find ṁcooling water
Recall: 𝑚̇𝑠𝑡𝑒𝑎𝑚 ∆𝐻𝑐𝑜𝑛𝑑𝑒𝑛𝑠𝑒𝑟 = − 𝑄̇𝑐𝑜𝑜𝑙𝑖𝑛𝑔 𝑤𝑎𝑡𝑒𝑟
𝑚̇𝑠𝑡𝑒𝑎𝑚 (𝐻6 − 𝐻5 ) = −𝑚̇𝑐𝑜𝑜𝑙𝑖𝑛𝑔 𝑤𝑎𝑡𝑒𝑟 𝐶𝑝 . ∆𝑇
𝑚̇𝑠𝑡𝑒𝑎𝑚 (𝐻6 − 𝐻5 )
𝑚̇𝑐𝑜𝑜𝑙𝑖𝑛𝑔 𝑤𝑎𝑡𝑒𝑟 =
−𝐶𝑝 . ∆𝑇
Recall perhitungan sebelumnya dan substitusi
66,34𝑥(191,832 − 2468,741)
𝑚̇𝑐𝑜𝑜𝑙𝑖𝑛𝑔 𝑤𝑎𝑡𝑒𝑟 = = 903,41 𝑘𝑔/𝑠
−4,18 (60 − 20)

2.Suatu gas mengikuti model P(V-b) = RT dimana b konstanta positif. Turunkan


persamaan Joule-Thompson coefficient gas tersebut. Dapatkah gas tersebut didinginkan
melalui throttling?

𝜕𝐻 𝜕𝐻
Mulai dengan: 𝑑𝐻 = ( 𝜕𝑇 ) 𝑑𝑇 + ( 𝜕𝑇 ) 𝑑𝑃 dan 𝑑𝐻 = 𝑇 𝑑𝑆 + 𝑉 𝑑𝑃
𝑃 𝑇
Solusi:
𝜕𝐻 𝜕𝐻
𝑑𝐻 = ( ) 𝑑𝑇 + ( ) 𝑑𝑃
𝜕𝑇 𝑃 𝜕𝑇 𝑇
𝜕𝐻
𝑑𝐻 = 𝐶𝑝 𝑑𝑇 + ( ) 𝑑𝑃 … … (𝑖)
𝜕𝑇 𝑇
𝜕𝐻
Perlu dicari ( 𝜕𝑇 )
𝑇
Recall: 𝑑𝐻 = 𝑇 𝑑𝑆 + 𝑉 𝑑𝑃
𝜕𝐻 𝜕𝑆
( ) = 𝑇 ( ) + 𝑉 … … (𝑖𝑖)
𝜕𝑃 𝑇 𝜕𝑃 𝑇
Dari model EOS yang diberikan soal

P(V − b) = RT
RT
𝑉= + 𝑏 … … (𝑖𝑖𝑖)
P
Recall Maxwell relation
𝜕𝑆 𝜕𝑉
( ) = −( )
𝜕𝑃 𝑇 𝜕𝑇 𝑃
From EOS (iii)
RT
𝑉= +𝑏
P
𝜕𝑉 R
( ) =
𝜕𝑇 𝑃 P
Maka
𝜕𝑆 R
( ) = − ( ) … … (𝑖𝑣)
𝜕𝑃 𝑇 P
Substitusi (iii) (iv) ke (ii)
𝜕𝐻 R RT
( 𝜕𝑃 ) = 𝑇 − (P) + P + 𝑏
𝑇
𝜕𝐻 𝑅𝑇 RT
( ) =− + + 𝑏 = 𝑏 … … (𝑣)
𝜕𝑃 𝑇 𝑃 P
Substitusi (v) ke (i)
𝑑𝐻 = 𝐶𝑝 𝑑𝑇 + 𝑏 𝑑𝑃
Pada persitiwa Throttling proses yang terjadi isenthalpic (dH=0) sehingga
𝐶𝑝 𝑑𝑇 = −𝑏 𝑑𝑃
𝑑𝑇 𝑏
∴( ) =−
𝑑𝑃 𝐻 𝐶𝑝
Dari persamaan akhir dapat disimpulkan bahwa gas tidak dapat didinginkan melalui
Throttling karena Grafik T vs P memiliki slope negative berarti penurunan tekanan akan
menaikkan Temperature (bukan mendinginkan)

3.Suatu vapor-compression refrigerator digunakan untuk mendinginkan natural gas


200MSCFD dari 140oF menjadi 40oF. Refrigerant HFC-134a, tekanan operasi:
evaporator 3 psia, condenser 80 psia, efisiensi compressor 66%. Tentukan (a) kerja
compressor (hp) dan (b) COP. Natural gas: Cp = 0,575 Btu/lbm.oF, BM = 19 lbm/lbmol
Solusi:
Condenser 2
3
80 psia

66% …Hp

Evaporator 10 kPa

4 1
o
Natural Gas 140oF 40 F Cp = 0,575 Btu/lbm
200 MSCFD 3 psia BM= 19 lbm/lbmol

Refrigerant HFC-134a
Dari P-H diagram
H1=H4= 33,125 Btu/lbm (isenthalpic)
H2= 92,5 Btu/lbm
H3’=123 Btu/lbm
Ask the assistants how to read and draw the vapor compression diagram

(a) Wcompressor
Tinjau kompresor (12)
𝑊𝑖𝑠𝑒𝑛𝑡𝑟𝑜𝑝𝑖𝑐 𝜂
Recall: 𝜂 = 𝑊 𝑊𝑎𝑐𝑡𝑢𝑎𝑙 = 𝑊
𝑎𝑐𝑡𝑢𝑎𝑙 𝑖𝑠𝑒𝑛𝑡𝑟𝑜𝑝𝑖𝑐
Recall: 𝑊𝑖𝑠𝑒𝑛𝑡𝑟𝑜𝑝𝑖𝑐 = 𝑚̇𝐻𝐹𝐶 . (𝐻2′ − 𝐻1 )
𝜂
𝑊𝑎𝑐𝑡𝑢𝑎𝑙 = … … (𝑖)
𝑚̇𝐻𝐹𝐶 . (𝐻2′ − 𝐻1 )
Perhitungan ṁ
Tinjau Evaporator (41)
Energy balance
𝑄̇𝐻𝐹𝐶 = −𝑄̇𝑔𝑎𝑠
𝑚̇𝐻𝐹𝐶 . (𝐻1 − 𝐻4 ) = −(𝑛̇ 𝑔𝑎𝑠 . 𝐶𝑝 Δ𝑇)
−(𝑛̇ 𝑔𝑎𝑠 . 𝐶𝑝 Δ𝑇)
𝑚̇𝐻𝐹𝐶 =
(𝐻1 − 𝐻4 )
Konversi rate mol ke lbm/s
𝑀𝑆𝐶𝐹 1000𝑠𝑐𝑓 𝑑𝑎𝑦
200 𝑀𝑆𝐶𝐹𝐷 = 200 𝑥 𝑥 = 2,315 𝑠𝑐𝑓/𝑠
𝑑𝑎𝑦 𝑀𝑆𝐶𝐹 86400𝑠
𝑝𝑠𝑖𝑎𝑓𝑡3
𝑅𝑇 10,73 𝑥 520 𝑅 𝑓𝑡 3
𝑅 𝑙𝑏𝑚𝑜𝑙
Recall: 𝑉 = = = 379,6
𝑃 14,7 𝑝𝑠𝑖𝑎 𝑙𝑏𝑚𝑜𝑙
𝑠𝑐𝑓 𝑙𝑏𝑚𝑜𝑙 𝑙𝑏𝑚
2,315 𝑥 𝑥19 = 0,116 𝑙𝑏𝑚/𝑠
𝑠 379,6 𝑠𝑐𝑓 𝑙𝑏𝑚𝑜𝑙
Plug in values
−0,116 𝑥 0,575 𝑥 (40 − 140) 𝑙𝑏𝑚
𝑚̇𝐻𝐹𝐶 = = 0,112 … … (𝑖𝑖)
(92,5 − 33,125) 𝑠
Substitusi ke (i)
0,112(123 − 92,5) 𝐵𝑡𝑢
𝑊𝑎𝑐𝑡𝑢𝑎𝑙 = = 5,1758
0,66 𝑠
Konversi ke HP
𝐵𝑡𝑢 1,4148 𝐻𝑃
5,1758 𝑥 = 7,323 𝐻𝑃
𝑠 𝐵𝑡𝑢/𝑠
(b) COP
𝑄
Recall 𝐶𝑂𝑃 = 𝑒𝑣𝑎𝑝𝑜𝑟𝑎𝑡𝑖𝑜𝑛
𝑊𝑛𝑒𝑡
Recall: 𝑄̇𝑒𝑣𝑎𝑝𝑜𝑟𝑎𝑡𝑖𝑜𝑛 = 𝑚̇𝐻𝐹𝐶 (𝐻2 − 𝐻1 )
Plug in numbers
𝑚̇𝐻𝐹𝐶 (𝐻2 − 𝐻1 ) 0,112(92,5 − 33,125)
𝐶𝑂𝑃 = = = 1,2848
𝑊𝑐𝑜𝑚𝑝𝑟𝑒𝑠𝑠𝑜𝑟 5,1758
80

3
4.Campuran dengan komposisi (molar): A = 45%, B= 35% dan C= 20% sebanyak 20 mol
dalam piston-silinder diekspansi menjadi 80 kPa, 70oC. Relasi Psat vs temperature
masing-masing zat mengikuti model Antoine berikut:
2940 2945 2972
ln 𝑃 𝑠𝑎𝑡𝐴 = 14,5 − 𝑡+237 ln 𝑃 𝑠𝑎𝑡 𝐵 = 14,3 − 𝑡+224 ln 𝑃 𝑠𝑎𝑡 𝐶 = 14,2 − 𝑡+209
(Psat dalam kPa dan t dalam oC)

Anggap sistem berkelakuan mengikuti Hukum Raoult.


(a) Tunjukkan bahwa pada kondisi akhir ekspansi, campuran tersebut berupa 2 fasa (gas-
cair).
(b) Tentukan banyaknya fasa gas (mol) pada kondisi akhir ekspansi.
Solusi:

n = 20 Psistem = 80 kPa
mol
T=70oC
ZA= 0,45
ZB= 0,35
ZC= 0,2

(a) Tunjukkan kondisi akhir campuran berupa 2 fasa


Penentuan Pisat
2940
ln 𝑃 𝑠𝑎𝑡𝐴 = 14,5 −
𝑡+237
2940
𝑃 𝑠𝑎𝑡𝐴 = exp (14,5 − ) = 137,48 𝑘𝑃𝑎
70 + 237
2945
ln 𝑃 𝑠𝑎𝑡 𝐵 = 14,3 − 𝑡+224
2945
𝑃 𝑠𝑎𝑡 𝐵 = exp (14,3 − ) = 72,457 𝑘𝑃𝑎
70 + 224
2972
ln 𝑃 𝑠𝑎𝑡 𝐶 = 14,2 − 𝑡+209
2972
𝑃 𝑠𝑎𝑡 𝐶 = exp (14,2 − ) = 34,732 𝑘𝑃𝑎
70 + 209

Recall 𝑃𝑏𝑢𝑏𝑏𝑙𝑒 = ∑ 𝑥𝑖 𝑃𝑖𝑠𝑎𝑡  Σyi=1


𝑃𝑏𝑢𝑏𝑏𝑙𝑒 = 0,45𝑥137,48 + 0,35𝑥72,457 + 0,2𝑥34,732 = 94,172 𝑘𝑃𝑎
1
Recall 𝑃𝑑𝑒𝑤 = ∑ 𝑦 /𝑃𝑠𝑎𝑡  Σxi=1
𝑖 𝑖
1
𝑃𝑑𝑒𝑤 = = 72,139 𝑘𝑃𝑎
0,45 0,35 0,2
137,48 + 72,457 + 34,732
Karena Pdew<Psistem<Pbubble maka sistem pada kondisi akhir berupa 2 fasa (gas-cair)
(b) Tentukan banyak mol gas pada kondisi akhir
Perhitungan Ki
𝑃𝑖𝑠𝑎𝑡
Recall: 𝐾𝑖 = 𝑃
137,48
𝐾𝐴 = = 1,72
80
72,457
𝐾𝐵 = = 0,91
80
34,732
𝐾𝐶 = = 0,43
80
𝑧 𝑖 𝐾𝑖 𝑧𝐾
Recall: 𝑦𝑖 =  ∑ 1+𝑉(𝐾
𝑖 𝑖
= ∑ 𝑦𝑖 = 1
1+𝑉(𝐾 −1) 𝑖 −1) 𝑖
𝑃𝑏𝑢𝑏𝑏𝑙𝑒 −𝑃
Dengan trial and error hitung V dengan tebakan awal 𝑉 = 𝑃
𝑏𝑢𝑏𝑏𝑙𝑒 −𝑃𝑑𝑒𝑤
94,172 − 80
𝑉= = 0,643
94,172 − 72,139
Tebakan pertama
Untuk V= 0,643
0,45𝑥(1,72) 0,35𝑥(0,91) 0,2𝑥(0,43)
∑ 𝑦𝑖 = + 1+0,643(0,91−1) + 1+0,643(0,43−1) = 1,00288
1+0,643(1,72−1)
Tebakan kedua
Untuk V=0,67217
0,45𝑥(1,782) 0,35𝑥(0,891) 0,2𝑥(0,455)
∑ 𝑦𝑖 = + 1+0,67217(0,891−1) + 1+0,67217(0,455−1) = 1,000000023 ≈ 1
1+0,67217(1,782−1)
Didapat V = 0,67217
Jika anda ingin tahu bagaimana caranya mendapat nilai V tanpa nebak-nebak
gunakanlah SOLVER (Ask assistant for detail)

Jumlah mol pada fasa gas = V x ntotal


Jumlah mol pada fasa gas = 0,67217 x 20 = 13,4434 mol
Soal Bonus: Jelaskan mengapa steam turbine dirancang untuk beroperasi pada kondisi
Superheated. Gunakan skematik diagram TS untuk membantu memperjelas jawaban
pertanyaan ini
Jawab:
Tujuan utama membuat superheated adalah agar semua fasa yang masuk turbin adalah fasa
uap, karena sedikit saja fasa cair berada pada turbin dapat menyebabkan kerusakan Blade
Turbine yang berputar kencang dan juga fasa cair dapat menyebabkan korosi
2

Diagram TS
1
T

4 3

S
TK 3081-Termodika Dasar A
UAS 2013/2014
1. Tinjau suatu heat pump dengan fluida kerja R-134a memiliki rate 60 kg/min. Kompresor
beroperasi pada 40 kW, dengan efisiensi 80%. Tekanan Evaporator sebesar 0,2 MPa.
Tentukan apakah heat pump dapat memanaskan CO2 cair hingga 40oC.
2. Tinjau aliran gas sebagaimana diperlihatkan pada gambar berikut. Tentukan (a)
persentase komponen A,B,C setelah proses injeksi dan (b) rate injeksi gas Y
Injeksi Gas Y
Gas 27,3%
Gas
A: … A: 6% (mol)
A: 11%
B: … B: 20% A: 28,9%
B: 20% Gas
C: … C: 74% B: 29,2%
Liquid
C: 69%
Proses C: 41,9%
72,7%
1 scf injeksi
State 2
State 1

Pada state 2 , Harga K: A=10,0 B=1,76 C=0,52


3. Tinjau suatu electric power plant siklus Rankine berbahan bakar gas bumi. Steam masuk
turbin pada 8,6 MPa,, 500oC. Steam keluar turbin masuk ke condenser pada 10 kPa.
Diketahui H1= 203,4 kJ/kg. Efisiensi generator 90%.Mol rate gas 30 MMSCFD Heating
value gas bumi 1000 BTU/SCF. Air pendingin masuk 20oC, keluar 60oC. pada rate 2,5
ton/detik Cp air = 4,18 kJ/kg.oC Heating value gas bumi 1000 BTU/SCF. Jika harga jual
listrik 0,1 US$/kWhe tentukan harga gas maksimum (US$/MMBTU) agar produsen
listrik tidak rugi. Note MWe = Mega Watt electricity
SOLUSI
TK 3081-Termodika Dasar A
UAS 2013/2014
1.Tinjau suatu heat pump dengan fluida kerja R-134a memiliki rate 60 kg/min. Kompresor
beroperasi pada 40 kW, dengan efisiensi 80%. Tekanan Evaporator sebesar 0,2 MPa
Tentukan apakah heat pump dapat memanaskan CO2 cair hingga 40oC.
Solusi:

Batas T = 30oC Const S

4 Condenser 3’

MPa
(ΔH)s = ηxWcom/ ṁ =
0,8x40/1 =32 kJ/kg
1 2
0,2
Evaporator
(ΔH)s

H (kJ/kg) 243 243+32=275


Pemanasan terjadi di condenser  cek secara grafis apakah temperature condenser cukup
untuk memanasi CO2 hingga 40oC
Kompressor 40 kW, eff 80%, mass rate working fluid = 60 kg/min = 1 kg/s
Power yang diterima fluida kerja = 40 x 80% = 32 kW (32 kJ/s)
Power kompresor = ṁΔHcompressor  (ΔH)s = (32 kJ/s)/(1kg/s)= 32 kJ/kg
Ask the assistants how to read and draw the vapor compression diagram
Hinlet kompresor = H2= 243 kJ/kg (dari chart at 0,2 Mpa)
Jadi Houtlet kompresor = 243+32= 275 kJ/kg
Posisi condenser: perpotongan garis H = 275 kJ/kg dengan garis isentropic ditarik dari
inlet kompresor (titik 2)
Baca pada grafik temperature fluida kerja dalam condenser = 340 K = 67oC
Karena diinginkan pemanasan sampai dengan 40oC maka heat pump dapat digunakan
untuk memenuhi kebutuhan pemanasan CO2 cair
2.Tinjau aliran gas sebagaimana diperlihatkan pada gambar berikut. Tentukan (a)
persentase komponen A,B,C setelah proses injeksi dan (b) rate injeksi gas Y
Solusi:
Injeksi Gas Y
Gas 27,3%
Gas
A: … A: 6% (mol)
A: 11%
B: … B: 20% A: 28,9%
B: 20% Gas
C: … C: 74% B: 29,2%
Liquid
C: 69%
Proses C: 41,9%
72,7%
1 scf injeksi
State 2
State 1

Pada state 2 , Harga K: A=10,0 B=1,76 C=0,52

Strategi: Hitung overall composition {zi} kemudian hitung banyaknya mol gas Y dengan
neraca material
Karena komposisi fasa gas {yi} diketahui maka komposisi overall {zi} dapat dihitung
dari:
𝑧𝐾
𝑖 𝑖 [1+𝑉(𝐾𝑖 −1)]𝑦𝑖
Recall: 𝑦𝑖 = 1+𝑉(𝐾 rearrange  𝑧𝑖 =
−1)
𝑖 𝐾𝑖
Plug in numbers
[1+𝑉(𝐾𝐴 −1)]𝑦𝐴 [1+0,273(10−1)]𝑥0,289
Untuk A: 𝑧𝐴 = = = 0,1
𝐾𝐴 10
[1+𝑉(𝐾𝐵 −1)]𝑦𝐵 [1+0,273(1,76−1)]𝑥0,292
Untuk B: 𝑧𝐵 = = = 0,2
𝐾𝐵 1,76
[1+𝑉(𝐾𝐶 −1)]𝑦𝐶 [1+0,273(0,52−1)𝑥0,419]
Untuk C: 𝑧𝐶 = = = 0,7
𝐾𝐶 0,52
(b) Mol rate Gas Y
Neraca Material:
(𝑀𝑜𝑙 𝐴 𝑠𝑡𝑎𝑡𝑒 1) + (𝑀𝑜𝑙 𝐴 𝑑𝑎𝑙𝑎𝑚 𝑔𝑎𝑠 𝑌) = (𝑀𝑜𝑙 𝐴 𝑑𝑎𝑙𝑎𝑚 𝑚𝑖𝑥𝑡𝑢𝑟𝑒 𝑠𝑡𝑎𝑡𝑒 2)
𝑛̇ 1 𝑦𝐴 𝑠𝑡𝑎𝑡𝑒 1 + 𝑛̇ 𝑌 𝑦𝐴 𝑔𝑎𝑠 𝑌 = 𝑛̇ 𝑡𝑜𝑡𝑎𝑙 𝑧𝐴
Recall 𝑛̇ 𝑡𝑜𝑡𝑎𝑙 = 𝑛̇ 1 + 𝑛̇ 𝑌
Maka 𝑛̇ 1 𝑦𝐴 𝑠𝑡𝑎𝑡𝑒 1 + 𝑛̇ 𝑌 𝑦𝐴 𝑔𝑎𝑠 𝑌 = (𝑛̇ 1 + 𝑛̇ 𝑌 )𝑧𝐴 Rearrange
𝑛̇ 1 (𝑦𝐴 𝑠𝑡𝑎𝑡𝑒 1 − 𝑧𝐴 )
𝑛̇ 𝑌 =
𝑧𝐴 − 𝑦𝐴 𝑔𝑎𝑠 𝑌
Plug in numbers
1 𝑠𝑐𝑓 𝑥 (0,11 − 0,1)
𝑛̇ 𝑌 = = 0,25 𝑠𝑐𝑓
0,1 − 0,06
3.Tinjau suatu electric power plant siklus Rankine berbahan bakar gas bumi. Steam masuk
turbin pada 8,6 MPa,, 500oC. Steam keluar turbin masuk ke condenser pada 10 kPa.
Diketahui H1= 203,4 kJ/kg. Efisiensi generator 90%.Mol rate gas 30 MMSCFD Heating
value gas bumi 1000 BTU/SCF. Air pendingin masuk 20oC, keluar 60oC. pada rate 2,5
ton/detik Cp air = 4,18 kJ/kg.oC Jika harga jual listrik 0,1 US$/kWhe tentukan harga gas
maksimum (US$/MMBTU) agar produsen listrik tidak rugi. Note MWe = Mega Watt
electricity
Solusi:
8,6 Mpa 500oC
2 Electric
1 generator

Nat gas: 30 MMSCFD


η=90%
Heat val: 1000 BTU/scf
η=90%
Condenser 10 kPa Harga jual: 0,1
US$/kWhe
4 3

Cooling water in Cooling water out 40oC


15oC 2,5 ton/detik Cp water: 4,18 kJ/kg.K

Tinjau Boiler (12)


𝑄̇𝐵𝑜𝑖𝑙𝑒𝑟 = 𝑚̇𝑠𝑡𝑒𝑎𝑚 . (𝐻2 − 𝐻1 )
𝑄̇𝐵𝑜𝑖𝑙𝑒𝑟
𝑚̇𝑠𝑡𝑒𝑎𝑚 =
(𝐻2 − 𝐻1 )
Perhitungan Q̇Boiler (kJ/s)
𝑄̇𝐵𝑜𝑖𝑙𝑒𝑟 = 𝑛̇ 𝑔𝑎𝑠 𝑥ℎ𝑒𝑎𝑡𝑖𝑛𝑔 𝑣𝑎𝑙𝑢𝑒
𝑀𝑀𝑆𝐶𝐹 𝐵𝑇𝑈 𝑘𝐽 𝑑𝑎𝑦 𝑘𝐽
𝑄̇𝐵𝑜𝑖𝑙𝑒𝑟 = 30𝑥106 𝑥1000 𝑥1,055 𝑥 = 366319,4
𝑑𝑎𝑦 𝑠𝑐𝑓 𝐵𝑇𝑈 86400 𝑠 𝑠
Keadaan 2 (8,6 MPa=8600 kPa, 500oC)
H2= 3391,6 kJ/kg (dari steam table superheated steam)
H1= 203,4 kJ/kg (diketahui dari soal)
Plug in numbers
𝑄̇𝐵𝑜𝑖𝑙𝑒𝑟
𝑚̇𝑠𝑡𝑒𝑎𝑚 =
(𝐻2 − 𝐻1 )
366319,4𝑘𝐽/𝑠
𝑚̇𝑠𝑡𝑒𝑎𝑚 = = 114,9 𝑘𝑔/𝑠
(3391,6 − 203,4)𝑘𝐽/𝑘𝑔
Tinjau Condenser (34)
Recall: 𝑚̇𝑠𝑡𝑒𝑎𝑚 ∆𝐻𝑐𝑜𝑛𝑑𝑒𝑛𝑠𝑒𝑟 = − 𝑄̇𝑐𝑜𝑜𝑙𝑖𝑛𝑔 𝑤𝑎𝑡𝑒𝑟
𝑚̇𝑠𝑡𝑒𝑎𝑚 (𝐻4 − 𝐻3 ) = −𝑚̇𝑐𝑜𝑜𝑙𝑖𝑛𝑔 𝑤𝑎𝑡𝑒𝑟 𝐶𝑝 . ∆𝑇
−𝑚̇𝑐𝑜𝑜𝑙𝑖𝑛𝑔 𝑤𝑎𝑡𝑒𝑟 𝐶𝑝 . ∆𝑇
𝐻3 = + 𝐻4
𝑚̇𝑠𝑡𝑒𝑎𝑚
Keadaan 4 (10 kPa)
H4=191,8 kJ/kg (dari steam table saturated liquid at 10 kPa)
𝑡𝑜𝑛
𝑚̇𝑐𝑜𝑜𝑙𝑖𝑛𝑔 𝑤𝑎𝑡𝑒𝑟 = 2,5 𝑑𝑒𝑡𝑖𝑘 = 2500 𝑘𝑔/𝑠
∆𝑇 = 𝑇𝑜𝑢𝑡𝑙𝑒𝑡 − 𝑇𝑖𝑛𝑙𝑒𝑡 = 40 − 15 = 25𝑜 𝐶
Cp = 4,18 kJ/kg.K
Plug in number
−𝑚̇𝑐𝑜𝑜𝑙𝑖𝑛𝑔 𝑤𝑎𝑡𝑒𝑟 𝐶𝑝 . ∆𝑇
𝐻3 = + 𝐻4
𝑚̇𝑠𝑡𝑒𝑎𝑚
−2500.4,18 .25
𝐻3 = + 191,8 = 2465,5 𝑘𝐽/𝑘𝑔
114,9
Tinjau Turbin (23)
Keadaan 2 (8,6 MPa=8600 kPa, 500oC)
H2= 3391,6 kJ/kg )
𝑘𝐽
∆𝐻𝑡𝑢𝑟𝑏𝑖𝑛 = 𝐻3 − 𝐻2 = 2465,5 − 3391,6 = −926 𝑘𝑔 … … (𝑖)

Tinjau Pompa (41)


Keadaan 4 (10 kPa saturated liquid)
H4= 191,8 kJ/kg
𝑘𝐽
∆𝐻𝑝𝑜𝑚𝑝𝑎 = 𝐻1 − 𝐻4 = 203,4 − 191,8 = 11,6 𝑘𝑔 … … (𝑖𝑖)
Δ𝐻𝑝𝑜𝑚𝑝𝑎
Recall 𝑊𝑐𝑦𝑐𝑙𝑒 = ∆𝐻𝑡𝑢𝑟𝑏𝑖𝑛 𝑥𝜂𝑔𝑒𝑛𝑒𝑟𝑎𝑡𝑜𝑟 + … … (𝑖𝑖𝑖)
𝜂𝑔𝑒𝑛𝑒𝑟𝑎𝑡𝑜𝑟
Substitusi (i) (ii) ke (iii) dengan ηgenerator = 0,9
11,6
𝑊𝑐𝑦𝑐𝑙𝑒 = −926𝑥0,9 + = −820,6 𝑘𝐽/𝑘𝑔
0,9
Harga gas maksimum agar tidak rugi dihitung dari
(𝑘𝑜𝑛𝑠𝑢𝑚𝑠𝑖 𝑔𝑎𝑠)(ℎ𝑎𝑟𝑔𝑎 𝑔𝑎𝑠) = (𝑒𝑙𝑒𝑐𝑡𝑟𝑖𝑐𝑖𝑡𝑦 𝑜𝑢𝑡𝑝𝑢𝑡)(ℎ𝑎𝑟𝑔𝑎 𝑗𝑢𝑎𝑙 𝑙𝑖𝑠𝑡𝑟𝑖𝑘)
(𝑒𝑙𝑒𝑐𝑡𝑟𝑖𝑐𝑖𝑡𝑦 𝑜𝑢𝑡𝑝𝑢𝑡)(ℎ𝑎𝑟𝑔𝑎 𝑗𝑢𝑎𝑙 𝑙𝑖𝑠𝑡𝑟𝑖𝑘)
(ℎ𝑎𝑟𝑔𝑎 𝑔𝑎𝑠) =
(𝑘𝑜𝑛𝑠𝑢𝑚𝑠𝑖 𝑔𝑎𝑠)
Recall 𝑁𝑒𝑡 𝑜𝑢𝑡𝑝𝑢𝑡 𝑒𝑙𝑒𝑐𝑡𝑟𝑖𝑐𝑖𝑡𝑦 = 𝑚̇𝑠𝑡𝑒𝑎𝑚 𝑥𝑊𝑐𝑦𝑐𝑙𝑒
𝑘𝐽
𝑁𝑒𝑡 𝑜𝑢𝑡𝑝𝑢𝑡 𝑒𝑙𝑒𝑐𝑡𝑟𝑖𝑐𝑖𝑡𝑦 = 114,9 𝑥 − 820,6 = −94286,94 = −94287 𝑘𝑊𝑒
𝑠
Basis 1 jam  −94286,94 𝑘𝑊𝑒 → 94287 𝑘𝑊ℎ𝑒
Perlu dicari Konsumsi gas per jam dalam MMBTU
(𝑘𝑜𝑛𝑠𝑢𝑚𝑠𝑖 𝑔𝑎𝑠) = 𝑛̇ 𝑔𝑎𝑠 𝑥𝐻𝑒𝑎𝑡𝑖𝑛𝑔 𝑣𝑎𝑙𝑢𝑒
𝑀𝑀𝑆𝐶𝐹 𝑀𝑀𝐵𝑇𝑈 𝑑𝑎𝑦
(𝑘𝑜𝑛𝑠𝑢𝑚𝑠𝑖 𝑔𝑎𝑠) = 30 𝑥1000 𝑀𝑀𝑆𝐶𝐹 𝑥 24 ℎ𝑟 = 1250 𝑀𝑀𝐵𝑇𝑈
𝑑𝑎𝑦
Plug in numbers
94287 𝑘𝑊ℎ𝑒 𝑥 0,1 𝑈𝑆$/𝑘𝑊ℎ𝑒
(ℎ𝑎𝑟𝑔𝑎 𝑔𝑎𝑠) = = 7,54 𝑈𝑆$/𝑀𝑀𝐵𝑇𝑈
1250𝑀𝑀𝐵𝑇𝑈
TK 3081-Termodika Dasar A
Perbaikan I Modul II 2013/2014

1. Tinjau suatu electric power plant siklus Rankine berbahan bakar gas bumi. Steam
masuk turbin pada 8,6 Mpa, 500oC. Steam keluar turbin masuk ke condenser pada 10
kPa. Tentukan efisiensi maksimum dari siklus tersebut!
2. Tinjau system dua fasa gas-cair: 50% A, 50% B, T= 100oC, bertekanan = P. Fraksi mol
A pada fasa cair = 0,25. Total mol dalam tangki 10 mol. Tentukan (a) tekanan system,
(b) mol fasa cair, (c) komposisi fasa gas. Harga equilibrium ratio (K) pada 100oF:

60 psia 65 psia 70 psia 75 psia


A 2,90 2,75 2,53 2,25
B 060 0,55 0,49 0,45
3. Tunjukkan melalui penurunan persamaan thermodynamic relations dan EOS bahwa
pada region dimana gradient dz/dT positif maka penurunan tekanan adiabatic suatu gas
akan mengakibatkan penurunan temperature gas tersebut. Hint: mulai dengan
H=H(T,P), apply thermo relations, Maxwell, then EOS.
4. Tinjau suatu vapor compression refrigerator dengan fluida kerja R-134a. Tentukan
maximum COP refrigerator tersebut bila tekanan evaporator 200 kPa dan beban
refrigerasi 142 kJ per kg refrigerant.
SOLUSI
TK 3081-Termodika Dasar A
Perbaikan I Modul II 2013/2014

1.Tinjau suatu electric power plant siklus Rankine berbahan bakar gas bumi. Steam masuk
turbin pada 8,6 Mpa, 500oC. Steam keluar turbin masuk ke condenser pada 10 kPa.
Tentukan efisiensi maksimum dari siklus tersebut!
Solusi: 8,6 Mpa 500oC
2
1

Condenser 10 kPa

4 3

Max Performance all isentropik

Tinjau Turbin (23)


Keadaan 2 (8,6 MPa=8600 kPa, 500oC)
H2= 3391,6 kJ/kg ; S2= 6,6858 kJ/kg.K (dari steam table superheated steam)
Keadaan 3 (10 kPa)
Tinjau keadaan isentropic S2=S3 =6,6858 kJ/kg.K
S3l= 0,6493 ;S3v=8,1511 ;H3l=191,8 ; H3v= 2584,8 (steam table superheated steam)
Karena S3l < S3< S3v maka steam keluar turbin memiliki 2 fasa
Find steam quality
Recall: 𝑆3 = 𝑆3𝑙 + 𝑥(𝑆3𝑣 − 𝑆3𝑙 )
𝑆 −𝑆 𝑙 6,6858−0,6493
𝑥 = (𝑆3𝑣−𝑆3𝑙 ) = 8,1511−0,6493 = 0,805
3 3
Maka

𝐻3 = 𝐻3𝑙 + 𝑥(𝐻3𝑣 − 𝐻3𝑙 ) = 191,8 + 0,805(2584,8 − 191,8)


𝑘𝐽
𝐻3 = 2118,165
𝑘𝑔

Tinjau Pompa (41)


Keadaan 4 (10 kPa saturated liquid)
H4= 191,8 kJ/kg
V = 1,01 cm3/g = 1,01 x 10-3 m3/kg
Tinjau keadaan isentropic
∆𝐻𝑝𝑜𝑚𝑝𝑎 = 𝑉. ∆𝑃 = 1,01𝑥10−3 𝑥(8600 − 10) = 8,676 𝑘𝐽/𝑘𝑔
∆𝐻𝑝𝑜𝑚𝑝𝑎 = 𝐻1 − 𝐻4  𝐻1 = 𝐻4 + ∆𝐻𝑝𝑜𝑚𝑝𝑎
𝐻1 = 191,8 + 8,676 = 200,5 𝑘𝐽/𝑘𝑔

Recall
|𝑊𝑐𝑦𝑐𝑙𝑒 |
𝜂𝑐𝑦𝑐𝑙𝑒 = 𝑥100% … … (𝑖)
𝑄𝐵𝑜𝑖𝑙𝑒𝑟
Perhitungan Wcycle
𝑊𝑐𝑦𝑐𝑙𝑒 = (𝑊𝑡𝑢𝑟𝑏𝑖𝑛 + 𝑊𝑝𝑜𝑚𝑝𝑎 ) = (𝐻3 − 𝐻2 ) + ∆𝐻𝑝𝑜𝑚𝑝𝑎
𝑘𝐽
𝑊𝑐𝑦𝑐𝑙𝑒 = (2118,165 − 3391,6) + 8,676 = −1264,759 … … (𝑖𝑖)
𝑘𝑔
Tinjau Boiler (12)
𝑘𝐽
𝑄𝑏𝑜𝑖𝑙𝑒𝑟 = 𝐻2 − 𝐻1 = 3391,6 − 200,5 = 3191,1 … … (𝑖𝑖𝑖)
𝑘𝑔
Substitusi (ii)(iii) ke (i)
1264,759
𝜂𝑐𝑦𝑐𝑙𝑒 = 𝑥100% = 39,6%
3191,1
2.Tinjau system dua fasa gas-cair: 50% A, 50% B, T= 100oC, bertekanan = P. Fraksi mol
A pada fasa cair = 0,25. Total mol dalam tangki 10 mol. Tentukan (a) tekanan system,
(b) mol fasa cair, (c) komposisi fasa gas. Harga equilibrium ratio (K) pada 100oF:

60 psia 65 psia 70 psia 75 psia


A 2,90 2,75 2,53 2,25
B 060 0,55 0,49 0,45
Solusi:
(a) Flash calculation untuk mencari tekanan sistem
Dicari P yang memberikan Σyi=ΣKixi=1
Diketahui xA= 0,25 maka xB=1-0,25=0,75

60 psia 65 psia 70 psia


xi K yi=Ki*xi K yi=Ki*xi K yi=Ki*xi
A 0,25 2,90 0,725 2,75 0,6875 2,53 0,6325
B 0,75 060 0,45 0,55 0,4125 0,49 0,3675
Σyi 1,175 Σyi 1,1 Σyi 1
Jadi tekanan sistem = 70 psia
(b) Mol fasa liquid=?
𝑧
Recall: 𝑥𝑖 = 1+𝑉(𝐾𝑖 −1)
𝑖
Ambil zat A untuk perhitungan: zA=50%=0,5; xA=0,25 KA=2,53
Plug in number and solve for V
𝑧𝐴 0,5
−1 −1
𝑥𝐴 0,25
𝑉 = (𝐾 = 2,53−1 = 0,653
𝐴 −1)
Mole fasa liquid = (1-V)x mol total= (1-0,653)x10 =3,46 mol
(c)Komposisi fasa gas Dari perhitungan sebelumnya yA =0,6325; yB= 0,3675
3.Tunjukkan melalui penurunan persamaan thermodynamic relations dan EOS bahwa pada
region dimana gradient dz/dT positif maka penurunan tekanan adiabatic suatu gas akan
mengakibatkan penurunan temperature gas tersebut. Hint: mulai dengan H=H(T,P),
apply thermo relations, Maxwell, then EOS.
Solusi:
Mulai dengan H=H(P,T)
𝜕𝐻 𝜕𝐻 𝜕𝐻
𝑑𝐻 = ( 𝜕𝑇 ) 𝑑𝑇 + ( 𝜕𝑃 ) 𝑑𝑃 … … (𝑖) Recall: ( 𝜕𝑇 ) = 𝐶𝑝 … … (𝑖𝑖)
𝑃 𝑇 𝑃
𝜕𝐻 𝜕𝑆
Recall 𝑑𝐻 = 𝑇 𝑑𝑆 + 𝑉𝑑𝑃  ( 𝜕𝑃 ) = 𝑇 (𝜕𝑃) + 𝑉
𝑇 𝑇
𝜕𝑆 𝜕𝑉
Recall Maxwell relation: (𝜕𝑃) = − (𝜕𝑇 )
𝑇 𝑃
Maka
𝜕𝐻 𝜕𝑆 𝜕𝑉
(
) = 𝑇 ( ) + 𝑉 = −𝑇 ( ) + 𝑉 … … (𝑖𝑖𝑖)
𝜕𝑃 𝑇 𝜕𝑃 𝑇 𝜕𝑇 𝑃
Substitusi (ii)(iii) ke (i)
𝜕𝑉
𝑑𝐻 = 𝐶𝑝𝑑𝑇 + [𝑉 − 𝑇 ( ) ] 𝑑𝑃
𝜕𝑇 𝑃
𝜕𝑉
Isenthalpic  0 = 𝐶𝑝𝑑𝑇 + [𝑉 − 𝑇 (𝜕𝑇 ) ] 𝑑𝑃
𝑃
1 𝜕𝑉
𝑑𝑇 = [𝑇 ( ) − 𝑉] 𝑑𝑃 … … (𝑖𝑣)
𝐶𝑝 𝜕𝑇 𝑃
𝜕𝑉 𝑅𝑇 𝜕𝑧 𝑅𝑧
Recall EOS PV=zRT  (𝜕𝑇 ) = (𝜕𝑇) +
𝑃 𝑃 𝑃 𝑃
𝜕𝑉 𝑅𝑇 𝜕𝑧 𝑧𝑅𝑇
 𝑇 (𝜕𝑇 ) = 𝑇 (𝜕𝑇) +
𝑃 𝑃 𝑃 𝑃
𝑅𝑇 𝑉 𝑧𝑅𝑇
Recall = dan =𝑉
𝑃 𝑧 𝑃
𝜕𝑉 𝑉𝑇 𝜕𝑧
 𝑇 (𝜕𝑇 ) = (𝜕𝑇) + 𝑉 … … (𝑣)
𝑃 𝑧 𝑃
Substitusi (v) ke (iv)
1 𝑉𝑇 𝜕𝑧
𝑑𝑇 = [( ( ) + 𝑉) − 𝑉] 𝑑𝑃
𝐶𝑝 𝑧 𝜕𝑇 𝑃
1 𝑉𝑇 𝜕𝑧
∆𝑇 = ( ( ) ) ∆𝑃
𝐶𝑝 𝑧 𝜕𝑇 𝑃
𝜕𝑧
Karena V,T,z,Cp semuanya positif maka saat (𝜕𝑇) positif dan ∆𝑃negatif (penurunan P)
𝑃
maka akan menyebabkan ∆𝑇 negatif (penurunan temperature)
4.Tinjau suatu vapor compression refrigerator dengan fluida kerja R-134a. Tentukan
maximum COP refrigerator tersebut bila tekanan evaporator 200 kPa dan beban
refrigerasi 142 kJ per kg refrigerant.
Solusi:
Ask the assistants how to read and draw the vapor compression diagram
ΔH= 142  H1=242 – 142 = 100
H1 = 242 -142 = 100 kJ/kg  Tarik Const S
garis di chart potong dengan
isnetropik dapat H3
4 3’
H3 = 278 kJ/kg
ΔH= 278-242 = 36 kJ/kg ln P
∆𝐻𝑒𝑣𝑎𝑝𝑜𝑟𝑎𝑡𝑖𝑜𝑛
Recall Max COP = (𝑊
𝑐𝑜𝑚𝑝𝑟𝑒𝑠𝑠𝑜𝑟 )𝑠

Max COP = 142/36 = 3,94 1 2

36

100 H (kJ/kg) 242 278


TK 3081-Termodika Dasar A
Perbaikan II Modul II 2013/2014

1.Suatu power plant siklus Rankine beroperasi dengan kondisi berikut:


Turbine power: 975 kJ/kg steam
Kerja Pompa: 8,865 kJ/kg steam
Condenser load: 2000 kJ/kg steam
Tekanan condenser: 100 kPa
Proses: Isentropic
Asumsi: boiler process = constant pressure
Jika daya tahan material boiler = 600oC, 100 bar tentukan apakah power plant tersebut
aman?
2.Tuliskan langkah-langkah secara detil untuk menghitung banyaknya liquid yang
terbentuk dari proses kompresi campuran zat A,B,C pada suhu tertentu. Diketahui data
Psat masing-masing zat, komposisi total {zi},tekanan awal dan tekanan akhir
3.Diketahui suatu zat pada 280oC mempunyai data PVT berikut:
P,bar 20 35 50 65
V, cm3/mol 2161 1164 758 534
o
Tentukan fugasitas zat tersebut pada 280 C, 60 bar. Tuliskan dengan jelas prosedur
penyelesaian soal!
4.Tunjukkan bahwa internal energy gas hanya merupakan fungsi dari temperatur (𝑑𝑈 =
𝐶𝑉 𝑑𝑇) Hint: Mulai dari Persamaan Entropi sebagai fungsi dari T dan V
SOLUSI
TK 3081-Termodika Dasar A
Perbaikan II Modul II 2013/2014

1.Suatu power plant siklus Rankine beroperasi dengan kondisi berikut:


Turbine power: 975 kJ/kg steam
Kerja Pompa: 8,865 kJ/kg steam
Condenser load: 2000 kJ/kg steam
Tekanan condenser: 100 kPa
Proses: Isentropic
Asumsi: boiler process = constant pressure
Jika daya tahan material boiler = 600oC, 100 bar tentukan apakah power plant tersebut
aman?
Solusi:
Constant Pressure Isentropic
1 2 process

Wturbine =975
kJ/kg steam
Wpump = 8,865
kJ/kg steam
4 3
Condenser
Condenser load =
100 kPa
Syarat aman Boiler 2000 kJ/kg steam
P= 100 bar = 10000 kPa
T= 600oC

Tinjau pompa (41)


Condenser beroperasi pada 100 kPa sehingga properties fluida masuk pompa:
V4= 1,043 cm3/gr = 1,043 x 10-3 m3/kg (Steam table F.2)
Wpompa = V4 (P1-P4) 
𝑊𝑝𝑜𝑚𝑝𝑎
𝑃1 = 𝑃4 +
𝑉4
Plug in numbers
8,865
𝑃1 = 100 + = 8599,52 𝑘𝑃𝑎 = 8,6 𝑀𝑃𝑎
1,043𝑥10−3
Karena daya tahan tekanan boiler adalah 10000 kPa atau 10 MPa maka dari sisi tekanan
Boiler AMAN
Tinjau condenser (34)
Condenser beroperasi pada 100 kPa
H4= 417,511 (Steam table F.2)
Qcondenser = H4-H3  H3 = H4 - Qcondenser
Qcondenser = -Condenser load = -2000 kJ/kg
H3 = 417,511 – (-2000) = 2417,511 kJ/kg

Tinjau turbin (23)


Wturbin = H3-H2  H2= H3 - Wturbin
H2 = 2417,511 – (-975) = 3392,511 kJ/kg
At P = 8,6 MPa  Hv= 2750,9 (steam table F.2)
Karena H2 > Hv Steam berupa superheated steam
P2 & H2 diketahui  cek steam table superheated steam
At P = 8,6 MPa dicari T dimana H = 3392 kJ/kg
Diperoleh T = 500oC
Karena daya tahan temperature Boiler adalah 600oC maka dari segi temperature Boiler
AMAN

Cara lain:
Syarat aman Boiler
P= 100 bar = 10000 kPa
T= 600oC
at P=10000 kPa; T= 600oC properties of superheated steam:
H2= 3622,7 kJ/kg (steam table F.2)

Tinjau turbin (23)


Wturbin = H3-H2  H3= Wturbin + H2

Tinjau condenser (34)


Qcondenser = H4-H3  Qcondenser = H4 – (Wturbin + H2)
H4 = (Wturbin + H2 + Qcondenser)

Tinjau pompa (41)


Wpompa = H4-H1  H1= H4 - Wpompa
H1= (Wturbin + H2 + Qcondenser)- Wpompa
H1= (-975) + 3622,7 +(-2000)-8,86 = 638,84 kJ/kg

Tinjau Boiler (12)


Recall: 𝑊̇𝑡𝑢𝑟𝑏𝑖𝑛 + 𝑊̇𝑝𝑢𝑚𝑝 = −(𝑄̇𝐵𝑜𝑖𝑙𝑒𝑟 + 𝑄̇𝐶𝑜𝑛𝑑𝑒𝑛𝑠𝑒𝑟 )
𝑄̇𝐵𝑜𝑖𝑙𝑒𝑟 = −(𝑊̇𝑡𝑢𝑟𝑏𝑖𝑛 + 𝑊̇𝑝𝑢𝑚𝑝 + 𝑄̇𝐶𝑜𝑛𝑑𝑒𝑛𝑠𝑒𝑟 )
𝑘𝐽
𝑄̇𝐵𝑜𝑖𝑙𝑒𝑟 = −(−975 + 8,86 + (−2000)) = 2966,14
𝑘𝑔
Batas ketahanan material boiler = H2 – H1 = 3622,7-638,84= 2983,86 kJ/kg
Karena Δ𝐻𝑏𝑜𝑖𝑙𝑒𝑟 > 𝑄𝐵𝑜𝑖𝑙𝑒𝑟 maka Power plant aman
2.Tuliskan langkah-langkah secara detil untuk menghitung banyaknya liquid yang
terbentuk dari proses kompresi campuran zat A,B,C pada suhu tertentu. Diketahui data
Psat masing-masing zat, komposisi total {zi},tekanan awal dan tekanan akhir
Solusi:
Cek state campuran at P1 (tekanan awal)
Recall:
𝑃𝑏𝑢𝑏𝑏𝑙𝑒 = ∑ 𝑧𝑖 𝑃𝑖𝑠𝑎𝑡
1
𝑃𝑑𝑒𝑤 =
∑ 𝑧𝑖 /𝑃𝑖𝑠𝑎𝑡
Jika PDew<P1<PBubble  Sistem memiliki 2 fasa
Jika P1<PDew  Sistem berfasa gas  liquid L1= 0
Jika PBubble<P1  Sistem berfasa cair  liquid L1= 1 mol

Jika sistem memiliki 2 fasa L1 didapat dari persamaan L1= 1-V1


V1 didapat dari flash calculation
Recall
𝑧𝑖 𝐾𝑖
∑ = ∑ 𝑦𝑖 = 1
1 + 𝑉(𝐾𝑖 − 1)

𝑃𝑖𝑠𝑎𝑡
Harga Ki didapat dari: 𝐾𝑖 = 𝑃1
𝑃𝑏𝑢𝑏𝑏𝑙𝑒 −𝑃
Dengan trial and error hitung V dengan tebakan awal 𝑉 = 𝑃
𝑏𝑢𝑏𝑏𝑙𝑒 −𝑃𝑑𝑒𝑤
Dengan cara yang sama dicari L2 (Liquid pada P2)

Liquid bertambah
sehingga
P2
Jumlah mol liquid yang
terbentuk = L2 – L1
P1
T
3.Diketahui suatu zat pada 280oC mempunyai data PVT berikut:

P,bar 20 35 50 65
V, cm3/mol 2161 1164 758 534
o
Tentukan fugasitas zat tersebut pada 280 C, 60 bar. Tuliskan dengan jelas prosedur
penyelesaian soal!

Solusi:
𝑃 𝑑𝑃
Recall: ln 𝜙𝑖 = ∫0 (𝑧𝑖 − 1) 𝑃

𝑓 𝑃 𝑑𝑃
ln 𝑃𝑖 = − ∫0 (1 − 𝑧𝑖 ) 𝑃

𝑓𝑖 𝑃 𝑑𝑃
= exp − ∫0 (1 − 𝑧𝑖 )
𝑃 𝑃

𝑃 𝑑𝑃
𝑓𝑖 = 𝑃. exp − ∫0 (1 − 𝑧𝑖 ) … … (𝑖)
𝑃

𝑃 𝑑𝑃
∫0 (1 − 𝑧𝑖 ) 𝑃
didapat dari luas grafik

𝑃𝑉
Nilai Z dihitung 𝑍 = 𝑅𝑇

𝑐𝑚3
20 𝑏𝑎𝑟 𝑥2161
Untuk P= 20 bar  𝑍 = 𝑏𝑎𝑟𝑐𝑚3
𝑚𝑜𝑙
= 0,94
83,14 𝑥(280+273)𝐾
𝑚𝑜𝑙.𝐾

Similarly

Z@35 bar = 0,886

Z@50 bar = 0,824

Z@65 bar = 0,755

Dari data pada table hitung (1-zi)/P untuk setiap tekanan


(1−𝑧𝑖 ) 1−0,94
Untuk P= 20  = = 0,003
𝑃 20

Hasil akhir

P,bar 20 35 50 65
Z 0,94 0,886 0,824 0,755
(1-Z)/P 0,003 0,0032 0,00352 0,00377
Plot data P vs (1-Z)/P pada grafik
0.005

0.004 y =1,753 E-5x + 0.00263

0.003

(1-Z)/P
0.002

0.001

0
0 10 20 30 40 50 60 70 80 90 100
P,bar

Gunakan regresi linear untuk mencari Persamaan kurva (Ask Assistant for detail)

Dari grafik dapat dilihat daerah di bawah grafik berupa trapezium

a= 0,00263; b= 0,00368; t = 60

Luas = (a+b)/2 x t = (0,00263+0,00368)/2 x 60 = 0,1893


Area
Substitusi ke (i) b
a t
𝑓𝑖 = 𝑃. exp(−Luas)

𝑓𝑖 = 60 𝑥 𝑒 −0,1893 = 49,65 𝑝𝑠𝑖

4.Tunjukkan bahwa internal energy gas hanya merupakan fungsi dari temperatur (𝑑𝑈 =
𝐶𝑉 𝑑𝑇) Hint: Mulai dari Persamaan Entropi sebagai fungsi dari T dan V
Solusi:
Start from S=S(T,V)
∂S 𝜕𝑆
𝑑𝑆 = ( ) 𝑑𝑇 + ( ) 𝑑𝑉 … … (𝑖)
𝜕𝑇 𝑉 𝜕𝑉 𝑇
Recall: dU = TdS – PdV …… (ii)
𝜕𝑈 𝜕𝑆
( 𝜕𝑇 ) = 𝑇 (𝜕𝑇)
𝑉 𝑉
𝜕𝑈
Recall: ( 𝜕𝑇 ) = 𝐶𝑣 maka
𝑉
𝜕𝑆 𝐶𝑣
( ) = … … (𝑖𝑖𝑖)
𝜕𝑇 𝑉 𝑇
𝜕𝑆 𝜕𝑃
Recall Maxwell Relation (𝜕𝑉) = (𝜕𝑇 ) … … (𝑖𝑣)
𝑇 𝑉
Substitusi (iii) (iv) ke (i)
𝑑𝑇 𝜕𝑃
𝑑𝑆 = 𝐶𝑣 + ( ) 𝑑𝑉 … … (𝑣)
𝑇 𝜕𝑇 𝑉
Substitusi 5 ke 2
𝑑𝑇 𝜕𝑃
𝑑𝑈 = 𝑇 (𝐶𝑣 + ( ) 𝑑𝑉) − 𝑃𝑑𝑉
𝑇 𝜕𝑇 𝑉
Rearrange
𝜕𝑃
𝑑𝑈 = 𝐶𝑣 𝑑𝑇 + [𝑇 ( ) − 𝑃] 𝑑𝑉 … … (𝑣𝑖)
𝜕𝑇 𝑉
Recall EOS P.V=R.T
𝜕𝑃 𝑅
 (𝜕𝑇 ) = 𝑉 … … (𝑣𝑖𝑖)
𝑉
Substitusi (vii) ke (vi)
𝑅
𝑑𝑈 = 𝐶𝑣 𝑑𝑇 + [𝑇 − 𝑃] 𝑑𝑉
𝑉
 P= R.T/V
𝑑𝑈 = 𝐶𝑣 𝑑𝑇 + [𝑃 − 𝑃]𝑑𝑉
∴ 𝑑𝑈 = 𝐶𝑣 𝑑𝑇
TK 3081 Termodinamika Dasar

Solusi UAS Modul 2

Semester 1 2013/2014

Soal Bonus (5):


Jelaskan mengapa Saudara perlu belajar mengenai fugacity.

Jawab: Fugasitas digunakan untuk menghitung harga K (equilibrium ratio). Harga K


digunakan untuk menghitung “flash” pada reservoir 2 fasa, separator, pipa gas kondensat.
 Maka mahasiswa TM perlu belajar fugacity.

1. (20) Consider saturation P-T curve of pure compund x has the following model:
4968.88
ln 𝑃 𝑠𝑎𝑡 = 17.94 −
𝑇
Where T in Kelvin.
From the following data, determine enthalpy of vaporization and entropy of vaporization
at 101.33 kPa
Psat, kPa Tsat, C Vliq, cm3/g Vvap, cm3/g
101.33 100 1.044 1673

Jawab:
4968.88
From ln 𝑃 𝑠𝑎𝑡 = 17.94 − 𝑇
𝑑(ln 𝑃 𝑠𝑎𝑡 ) 4968.88
=
𝑑𝑇 𝑇2
1 𝑑(𝑃 𝑠𝑎𝑡 ) 4968.88
=
𝑃𝑠𝑎𝑡 𝑑𝑇 𝑇2
𝑑(𝑃 𝑠𝑎𝑡 ) 4968.88 𝑠𝑎𝑡
= 𝑃
𝑑𝑇 𝑇2
Recall Clapeyron:
𝑑𝑃 𝑠𝑎𝑡 ∆𝐻 𝑙𝑣
=
𝑑𝑇 𝑇∆𝑉𝑙𝑣
Then
∆𝐻 𝑙𝑣 4968.88 𝑠𝑎𝑡
= 𝑃
𝑇∆𝑉𝑙𝑣 𝑇2
4968.88 𝑠𝑎𝑡 𝑙𝑣
∆𝐻 𝑙𝑣 = 𝑃 ∆𝑉
𝑇
Plug in numbers
4968.88
∆𝐻 𝑙𝑣 = 101.33(1673 − 1.044) × 10−3 = 2256.9 𝑘𝐽/𝑘𝑔
100 + 273
(enthalpy of vaporization)
𝑙𝑣
∆𝐻 𝑙𝑣 2256.9
∆𝑆 = = = 6.05 𝑘𝐽/(𝑘𝑔. 𝐾)
𝑇 373
(entropy of vaporization)

2. (40) Consider a Rankine cycle power plant with the following operation condition:
Heat rate Pressure, Mpa Temperature, ℃ Mass rate Efficiency
Item
MMBTUD Inlet Outlet Inlet Outlet Ton/hour %
Boiler 1000 8.8 475
Turbine 8.8 475 80
Cooling water 15 55 190
Pump 90
cp cooling water 4.2 kJ/(kg.K)
Determine (a) net power plant output (MW), (b) turbine efficiency and (c) cycle
efficiency.

Jawab:
① 8.8 MPa, 475 ℃
boiler

Wp 1000 MMBTUD

pump tur- W=? Eff=?


bin
e

(dua fasa)
Sat. liquid 80 ℃
④ ③

Cooling water Qc
15 ℃, 190 ton/jam 55 ℃

(a) Kerja turbin=?


Wturbin = msteam ∆𝐻𝑡𝑢𝑟𝑏𝑖𝑛 = msteam (H3 – H2)
H2 dari steam table
msteam dihitung dari neraca energi di boiler
H3 dari neraca energi di condenser
Neraca energi boiler (perhitungan 𝑚𝑠𝑡𝑒𝑎𝑚 ):
Qboiler = Qpembakaran
Heat input = msteam (H2 – H1)  msteam = Heat input / (H2 – H1)
𝑘𝐽
Heat input = 1000 𝑀𝑀𝐵𝑇𝑈𝐷 = 1000 × 106 𝐵𝑇𝑈⁄𝑑𝑎𝑦 × 1.055 ⁄𝐵𝑇𝑈 ×
𝑑𝑎𝑦⁄ ℎ𝑜𝑢𝑟⁄
1 24 ℎ𝑜𝑢𝑟 × 1 3600 𝑠 = 12210.65 𝑘𝐽/𝑠
H2 dari steam table at 8.8 MPa, 475 ℃: H2 = 3326.5 kJ/kg
H1 dihitung dari neraca energi pompa:
(∆𝐻𝑝𝑢𝑚𝑝 )
H1 = H4 + (∆Hpump)s dengan ∆𝐻𝑝𝑢𝑚𝑝 = 𝑆
dan (∆𝐻𝑝𝑢𝑚𝑝 )𝑆 = 𝑉4 (𝑃1 − 𝑃4 )
𝜂𝑝𝑢𝑚𝑝
P1 = P2 = 8.8 Mpa P4 = 47.36 kPa
Sat. Liquid 80 ℃  H4 = H4l = 334.9 kJ/kg; V4 = V4l = 1.029 x 10-3 m3/kg;
Maka
(∆𝐻𝑝𝑢𝑚𝑝 )𝑆 = 𝑉(𝑃1 − 𝑃4 ) = 1.029 x 10−3 (8800 − 47.36) = 9.0065 kJ/kg
(∆𝐻𝑝𝑢𝑚𝑝 )𝑆 9.0065
∆𝐻𝑝𝑢𝑚𝑝 = = = 10.007 𝑘𝐽/𝑘𝑔
𝜂𝑝𝑢𝑚𝑝 0.9
𝐻1 = 𝐻4 + (∆𝐻𝑝𝑢𝑚𝑝 )𝑠 = 334.9 + 9.0065 = 343.9065 𝑘𝐽/𝑘𝑔
𝐻𝑒𝑎𝑡 𝑖𝑛𝑝𝑢𝑡 12210.65
𝑚𝑠𝑡𝑒𝑎𝑚 = = = 4.094 𝑘𝑔/𝑠
𝐻2 − 𝐻1 3326.5 − 343.9065

Neraca energi condenser (perhitungan H3):


𝑚𝑠𝑡𝑒𝑎𝑚 (𝐻4 − 𝐻3 ) = − 𝑚𝑐𝑜𝑜𝑙𝑖𝑛𝑔 𝑤𝑎𝑡𝑒𝑟 𝑐𝑝 ∆𝑇
𝑚𝑐𝑜𝑜𝑙𝑖𝑛𝑔 𝑤𝑎𝑡𝑒𝑟 𝑐𝑝 ∆𝑇
𝐻3 = 𝐻4 +
𝑚𝑠𝑡𝑒𝑎𝑚
𝑡𝑜𝑛 𝑘𝐽 𝑘𝑔 1 𝑗𝑎𝑚
190 𝑗𝑎𝑚 4.2 (55 − 15) 𝐾 × 1000
𝑘𝑔. 𝐾 𝑡𝑜𝑛 × 3600 𝑠
𝐻3 = 334.9 𝑘𝐽/𝑘𝑔 +
𝑘𝑔
4.094 𝑠
𝐻3 = 2500.76 𝑘𝐽/𝑘𝑔

Maka
𝑊𝑡𝑢𝑟𝑏𝑖𝑛 = 𝑚𝑠𝑡𝑒𝑎𝑚 (𝐻3 − 𝐻2 ) = 4.094 (2500.76 − 3326.5) = −3380.58 𝑘𝐽/𝑠
Net power plant output = 𝑊𝑡𝑢𝑟𝑏𝑖𝑛 + 𝑊𝑝𝑢𝑚𝑝 = 𝑊𝑡𝑢𝑟𝑏𝑖𝑛 + 𝑚𝑠𝑡𝑒𝑎𝑚 ∆𝐻𝑝𝑢𝑚𝑝 =
𝑘𝐽
−3380.58 + 4.094 × 10.007 = −3339.61 = −3.34 𝑀𝑊
𝑠
Tanda minus (-) menyatakan output.

(b) Pada kondisi 2


𝑃2 = 8800 𝑘𝑃𝑎 𝑇2 = 475℃
Dari superheated steam table, 𝐻2 = 3326.5 𝑘𝐽/𝑘𝑔 dan 𝑆2 = 6.5904 𝑘𝐽/(𝑘𝑔. 𝐾)
Pada kondisi 3
T3 = 80 ℃
𝐻3𝑙 = 334.9 𝑘𝐽/𝑘𝑔 𝑆3𝑙 = 1.0753 𝑘𝐽/(𝑘𝑔. 𝐾)
𝐻3𝑣 = 2643.8 𝑆3𝑣 = 7.6132 𝑘𝐽/(𝑘𝑔. 𝐾)

Check the phase of the output:


Because we assume that the turbine is isentropic, then S3 = S2 = 6.5904 kJ/(kg.K)
Because S3l < S3 < S3v, we can conclude that the output is in two phase
So,
𝑆3 = 𝑆3𝑙 + 𝑥(𝑆3𝑣 − 𝑆3𝑙 )
6.5904 = 1.0753 + 𝑥(7.6132 − 1.0753)
𝑥 = 0.844

𝐻3 = 𝐻3𝑙 + 𝑥(𝐻3𝑣 − 𝐻3𝑙 )


𝐻3 = 334.9 + 0.844(2643.8 − 334.9)
𝐻3 = 2283.61 𝑘𝐽/𝑘𝑔

∆𝐻𝑡𝑢𝑟𝑏𝑖𝑛 ∆𝐻𝑡𝑢𝑟𝑏𝑖𝑛 2500.76−3326.5 825.74


Turbine efficiency = (∆H)s
= = 2283.61−3326.5 = 1042.89 = 80%
𝐻3 −𝐻2

𝑛𝑒𝑡 𝑝𝑜𝑤𝑒𝑟 𝑝𝑙𝑎𝑛𝑡 𝑜𝑢𝑡𝑝𝑢𝑡 3339.61


(c) Cycle efficiency = = 12210.65 = 27.35 %
𝑄𝑏𝑜𝑖𝑙𝑒𝑟

3. (20) Tinjau suatu eksperimen PVT di lab menggunakan bejana transparan sebagaimana
diperlihatkan pada gambar berikut (dari state 1, diinjeksi gas Y, menjadi state 2). Semua
data komposisi dalam persen molar. Tentukan banyaknya gas Y yang telah diinjeksikan
ke dalam bejana (dalam scf) sehingga sistem menjadi state 2.
Gas 27.3% (mol)
A: 28.9%
Gas Gas Y: Gas
B: 29.2%
A: 11% A: ... Injeksi A: 6%
C: 41.9%
B: 20% B: ... B: 20%
C: 69% C: ... C: 74%
Liquid
72.7%
1 scf

State 1 Proses: Injeksi State 2


Pada state 2, harga K: A=10.0 B=1.76 C=0.52

Jawab:
State 2
𝑖 𝑖𝑧𝑘
Recall 𝑦𝑖 = 1+𝑉(𝑘 −1)𝑖
So we can calculate 𝑧𝐴 , 𝑧𝐵 , 𝑧𝐶
𝑧𝐴 𝑘𝐴 𝑧𝐴 . 10
𝑦𝐴 = ↔ 0.289 = ↔ 𝑧𝐴 = 0.1
1 + 𝑉(𝑘𝐴 − 1) 1 + 0.273(10 − 1)
𝑧𝐵 𝑘𝐵 𝑧𝐵 (1.76)
𝑦𝐵 = ↔ 0.292 = ↔ 𝑧𝐵 = 0.2
1 + 𝑉(𝑘𝐵 − 1) 1 + 0.273(1.76 − 1)
𝑧𝐶 𝑘𝐶 𝑧𝐶 (0.52)
𝑦𝐶 = ↔ 0.419 = ↔ 𝑧𝐶 = 0.7
1 + 𝑉(𝑘𝐶 − 1) 1 + 0.273(0.52 − 1)
Recall material balance:
(mol gas A state 1) + (mol gas A in gas Y) = (mol gas A state 2)
𝑛̇ 1 . 𝑦𝐴 𝑖𝑛 𝑠𝑡𝑎𝑡𝑒 1 + 𝑛̇ 𝑦 . 𝑦𝐴 𝑖𝑛 𝑔𝑎𝑠 𝑌 = 𝑛̇ 𝑡𝑜𝑡𝑎𝑙 . 𝑦𝐴 𝑖𝑛 𝑠𝑡𝑎𝑡𝑒 2
Remember that
𝑛̇ 𝑡𝑜𝑡𝑎𝑙 = 𝑛̇ 1 + 𝑛̇ 𝑦
So,
𝑛̇ 1 . 𝑦𝐴 𝑖𝑛 𝑠𝑡𝑎𝑡𝑒 1 + 𝑛̇ 𝑦 . 𝑦𝐴 𝑖𝑛 𝑔𝑎𝑠 𝑌 = 𝑛̇ 1 . 𝑦𝐴 𝑖𝑛 𝑠𝑡𝑎𝑡𝑒 2 + 𝑛̇ 𝑦 . 𝑦𝐴 𝑖𝑛 𝑠𝑡𝑎𝑡𝑒 2
𝑛̇ 𝑦 . (𝑦𝐴 𝑖𝑛 𝑔𝑎𝑠 𝑌 − 𝑦𝐴 𝑖𝑛 𝑠𝑡𝑎𝑡𝑒 2 ) = 𝑛̇ 1 . (𝑦𝐴 𝑖𝑛 𝑠𝑡𝑎𝑡𝑒 2 − 𝑦𝐴 𝑖𝑛 𝑠𝑡𝑎𝑡𝑒 1 )
1(0.1 − 0.11)
𝑛̇ 𝑦 =
0.06 − 0.1
𝑛̇ 𝑦 = 0.25 𝑠𝑐𝑓
So, the gas y injected is 0.25 scf

4. (20) Tinjau suatu vapor-compression refrigerator dengan refrigerant R134a beroperasi


pada kondisi berikut: beban refrigerasi 5 ton; compressor inlet 0.2 Mpa; compressor
outlet 1 Mpa, 60 ℃. Sistem penggerak kompresor adalah motor listrik dengan efisiensi
80%. Tentukan: (a) biaya operasi refrigerator per bulan (30 hari) jika harga listrik Rp
1000 per kWh. (b) COP refrigerator.

Jawab:
④ 1 MPa, 60 ℃
condenser

Wp Qb motor
throttling
X valve Compre 5 MW
ssor

η = 80%

0.2 MPa
evaporator
① ②

Qc
5 ton refrig = 5 x 200 BTU/menit = 1000 BTU/menit x 1 menit/60 s = 50/3 BTU/s
5 ton refrig = 5 x 211 kJ/menit x 1 menit/60 s = 17.58 kJ/s
Dari grafik refrigerant di atas didapat:
H2 = 243 kJ/kg
H3 = 291.667 kJ/kg
H1 = H4 = 106.67 kJ/kg

(a) Look at compressor:


(∆𝐻)𝑐𝑜𝑚𝑝𝑟𝑒𝑠𝑠𝑜𝑟 = 𝐻3 − 𝐻2 = 48.667 𝑘𝐽/𝑘𝑔
(∆𝐻)𝑐𝑜𝑚𝑝𝑟𝑒𝑠𝑠𝑜𝑟 48.667
𝑊𝑐𝑜𝑚𝑝𝑟𝑒𝑠𝑠𝑜𝑟 = = = 60.83375 𝑘𝐽/𝑘𝑔
𝜂 0.8
Kemudian:
𝑄̇𝑐 = 𝑚̇(𝐻2 − 𝐻1 )
𝑄̇𝑐 17.58
𝑚̇𝑟𝑒𝑓𝑟𝑖𝑔𝑒𝑟𝑎𝑛𝑡 = = = 0.129 𝑘𝑔/𝑠
𝐻2 − 𝐻1 243 − 106.67
Jadi,
𝑊𝑖𝑛𝑝𝑢𝑡 = 𝑊𝑐𝑜𝑚𝑝𝑟𝑒𝑠𝑠𝑜𝑟 × 𝑚̇𝑟𝑒𝑓𝑟𝑖𝑔𝑒𝑟𝑎𝑛𝑡 = 60.83375 × 0.129 = 7.845 𝑘𝐽/𝑠
Net electricity input = 7.845 kWh/jam
Biaya operasi refrigerator = (net electricity input) x (harga satuan)
= 7.845 kWh/jam x Rp 1000/kWh
= Rp 7845/jam x 24 jam/hari x 30 hari/bulan
= Rp 5,648,400/bulan

|𝑄𝑐 | 𝐻2 −𝐻1 243−106.67


(b) 𝐶𝑂𝑃 = =𝑊 = = 2.241
𝑊 𝑐𝑜𝑚𝑝𝑟𝑒𝑠𝑠𝑜𝑟 60.83375
TK 3081 Termodinamika Dasar
Ujian Perbaikan Modul 2
Semester 1 2013/2014

1. (20) Starting with 𝐻 = 𝐻(𝑇, 𝑃) derive equations to show that for real gases Joule-Thomson
𝜕𝑧
coefficient is a function of 𝐶𝑝, 𝑉, 𝑇, 𝑧, and (𝜕𝑇)
𝑃

2. (20) Consider a Rankine cycle power plant with the following operating conditions:

P, MPa T, ℃
In Out Out In
Boiler 8.8 475
Turbine 8.8 475 80*
*two-phase
Determine the minimum heat input to the boiler for producing 5 MW net power plant
output

3. (30) Tinjau suatu mixture dengan komposisi pada tabel. Dengan asumsi ideal solution
isilah pertanyaan pada tabel.

Zat Moles Psat @ 80℃ Pbubble Pdew @ 80℃ 110 kPa


kPa kPa kPa Gas mol Liq mol
A 0.45 195.75 … …
B 0.35 97.84 … … … …
C 0.20 50.32 … …
Total … …

4. (20) Campuran A/B mempunyai 90


mixture properties sebagaimana 80
diperlihatkan pada gambar di samping 70
ini. Bila anda campurkan 5 liter A dan 5 60
liter B, berapa volume (liter) campuran 50
V (L/mol)

yang akan anda peroleh? Berapa error 40

yang akan terjadi bila anda 30


20
mengasumsikan bahwa campuran
10
adalah ideal mixture?
0
(𝑣𝑜𝑙 𝑖𝑑𝑒𝑎𝑙 − 𝑣𝑜𝑙 𝑎𝑘𝑡𝑢𝑎𝑙) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
𝑒𝑟𝑟𝑜𝑟 =
𝑣𝑜𝑙 𝑎𝑘𝑡𝑢𝑎𝑙 xA
TK 3081 Termodinamika Dasar
Solusi Ujian Perbaikan Modul 2
Semester 1 2013/2014
1. (20) Starting with 𝐻 = 𝐻(𝑇, 𝑃) derive equations to show that for real gases Joule-Thomson
𝜕𝑧
coefficient is a function of 𝐶𝑝, 𝑉, 𝑇, 𝑧, and (𝜕𝑇)
𝑃
Jawab:

Start with 𝐻 = 𝐻(𝑇, 𝑃)


𝜕𝑇
Joule Thompson Coefficient: 𝜇𝐽𝑇 = (𝜕𝑃) ……..….(1)
𝐻
Recall 3 basic equations:
𝜕𝐻 𝜕𝐻
 𝑑𝐻 = ( 𝜕𝑇 ) 𝑑𝑇 + ( 𝜕𝑃 ) 𝑑𝑃…………….….(2)
𝑃 𝑇
 𝑃𝑉 = 𝑧𝑅𝑇…………………………………...(3)
 𝑑𝐻 = 𝑇𝑑𝑠 + 𝑉𝑑𝑃…………………………...(4)

From (2),
𝜕𝐻
𝑑𝐻 = 𝐶𝑃 𝑑𝑇 + ( 𝜕𝑃 ) 𝑑𝑃………………….…(5)
𝑇

From (3),
𝜕𝑉 𝑧𝑅 𝜕𝑧 𝑅𝑇
(𝜕𝑇 ) = + (𝜕𝑇) ………………………(6)
𝑃 𝑃 𝑃 𝑃

From (4),
𝜕𝐻 𝜕𝑠
( 𝜕𝑃 ) = 𝑇 (𝜕𝑃) + 𝑉
𝑇 𝑇

𝜕𝐻 𝜕𝑉
( 𝜕𝑃 ) = −𝑇 (𝜕𝑇 ) + 𝑉……………………...(7)
𝑇 𝑃

Substitute (6) to (7),

𝜕𝐻 𝑧𝑅 𝜕𝑧 𝑅𝑇
( ) = −𝑇 [ + ( ) ]+𝑉
𝜕𝑃 𝑇 𝑃 𝜕𝑇 𝑃 𝑃

𝜕𝐻 𝑉 𝜕𝑧 𝑉
( ) = −𝑇 [ + ( ) ] + 𝑉
𝜕𝑃 𝑇 𝑇 𝜕𝑇 𝑃 𝑧

𝜕𝐻 𝑉𝑇 𝜕𝑧
( ) = −𝑉 − ( ) +𝑉
𝜕𝑃 𝑇 𝑧 𝜕𝑇 𝑃
𝜕𝐻 𝑉𝑇 𝜕𝑧
( 𝜕𝑃 ) = − (𝜕𝑇) …………………………..(8)
𝑇 𝑧 𝑃

Joule Thompson  isenthalpic, then 𝑑𝐻 = 0

From (5),

𝜕𝐻
0 = 𝐶𝑃 𝑑𝑇 + ( ) 𝑑𝑃
𝜕𝑃 𝑇

Substitute (8),

𝑉𝑇 𝜕𝑧
𝐶𝑃 𝑑𝑇 = ( ) 𝑑𝑃
𝑧 𝜕𝑇 𝑃

𝑑𝑇 𝑉𝑇 𝜕𝑧
( ) = ( )
𝑑𝑃 𝐻 𝑧𝐶𝑃 𝜕𝑇 𝑃

From (1),

𝑉𝑇 𝜕𝑧
𝜇𝐽𝑇 = ( )
𝑧𝐶𝑃 𝜕𝑇 𝑃

2. (20) Consider a Rankine cycle power plant with the following operating conditions:

P, MPa T, ℃
In Out InOut
Boiler 8.8 475
Turbine 8.8 475 80*
*two-phase
Determine the minimum heat input to the boiler for producing 5 MW net power plant
output

Jawab:
① 8.8 MPa, 475 ℃
boiler

Wp Qb

pump tur- 5 MW
bin
e

(dua fasa)
80 ℃
condenser
④ ③

Qc

Lihat steam table, pada 475 ℃ dan 8.8 MPa,

H2 = 3326.5 kJ/kg

S2 = 6.5904 kJ/kg.K

Asumsikan turbin isentropic, maka

S2 = S3 = 6.5904 kJ/kg.K

Pada 80 ℃, kondisi two phase, maka

S3L = 1.0753 kJ/kg.K H3L = 334.9 kJ/kg

S3V = 7.6132 kJ/kg.K H3V = 2643.8 kJ/kg

S3 = x.S3V + (1-x).S3L

x = 0.8436  steam percentage

H3 = x.H3V + (1-x).H3L

H3 = 2282.63 kJ/kg

Kita peroleh

WS turbin = ΔH = H3 – H2 = 2282.63 – 3326.5 = -1043.87 kJ/kg

Perhatikan bahwa pada pump proses isentropic,


𝑊 𝑃 = 𝑉(𝑃1 − 𝑃4 )

dengan

𝑃1 = 𝑃2 = 8800 𝑘𝑃𝑎

𝑃4 = 𝑃𝑠𝑎𝑡 3 = 47.36 𝑘𝑃𝑎

𝑉4 = 1.029𝑥10−3 𝑚3 /𝑘𝑔 (saturated liquid)

maka

𝑊 𝑃 = 1.029𝑥10−3 . (8800 − 47.36 ) = 9.006 𝑘𝐽/𝑘𝑔

Kemudian

𝑊̇𝑛𝑒𝑡 = −5 𝑀𝑊 = −5000 𝑘𝐽/𝑠

𝑊𝑛𝑒𝑡 = 𝑊𝑆 𝑡𝑢𝑟𝑏𝑖𝑛 + 𝑊 𝑃 𝑝𝑢𝑚𝑝 = −1043.87 + 9.006 = −1034.864 𝑘𝐽/𝑘𝑔


𝑊̇ −5000
𝑚̇𝑠𝑡𝑒𝑎𝑚 = 𝑊𝑛𝑒𝑡 = −1034.864 = 4.83 𝑘𝑔/𝑠
𝑛𝑒𝑡

Pada kondisi 4, saturated liquid 80 ℃

𝐻4 = 𝐻3𝐿 = 334.9 𝑘𝐽/𝑘𝑔

Maka

𝑄𝐶 = 𝐻4 − 𝐻3 = 334.9 − 2282.63 = −1947.73 𝑘𝐽/𝑘𝑔

Perhatikan bahwa

𝑊𝑛𝑒𝑡 = −(𝑄𝑏 + 𝑄𝐶 )

−1034.864 = −(𝑄𝑏 − 1947.73)

𝑄𝑏 = 2983.594 𝑘𝐽/𝑘𝑔

Lalu

𝑄𝑏̇ = 𝑄𝑏 . 𝑚̇ = 2983.594 𝑥 4.83 = 14415.39 𝑘𝐽/𝑠 = 14.4 𝑀𝑊

Jadi, minimum heat input untuk memproduksi 5 MW net power plant adalah 14.4 MW
TK 3081 – Termodinamika Dasar
Soal Latihan Mandiri

1. Determine the max power that you can get from LNG regasification (at -160 ℃) when the ambient
air temperature at the regasification plant is 25 ℃ and the volume rate of the natural gas leaving the
regasification plant is 500 MMSCFD.
LNG properties:
∆𝐻𝑒𝑣𝑎𝑝 = 500 𝑘𝐽/𝑘𝑔 (at -160 ℃); MW = 17 lb/lbmol
(Answer: 0.096 GW)

2. Consider ethane gas in a steel tank of 350 liters at 25 ℃, 2200 kPa. Based on Pitzer correlation for
2nd viral coefficient, determine the pressure of the gas if it is heated to 220 ℃. Properties of ethane:
BM = 30 g/mol, 𝜔=1.0, Tc=305.3 K, Pc=48.7 bar, Vc=145.5 cm3/mol, Zc=0.279
Pitzer correlation for 2nd viral coefficient: Find in textbook
(Answer: 44.92 bar)

3. Tinjau suatu proses pembakaran metana dengan udara berlebih 20%. Gas panas produk
pembakaran digunakan untuk memanasi air hingga menjadi saturated steam (x=100%). Temperatur
air masuk 35℃ dan steam keluar pada 100℃. Reaktan masuk pada 1 bar 25℃. Temperatur flue gas
140℃. Steam digunakan sebagai sumber energi reservoir thermal suatu heat engine. Heat sink dari
heat engine adalah air laut 20℃. H2O keluar reservoir thermal dalam keadaan liquid (saturated
water). Tentukan laju minimum metana dalam MMSCFD untuk menghasilkan kerja heat engine
sebesar 2 MW. Entalpi penguapan air = 2257 J/gram (pada 100℃), anggap Cp air konstan 4,18
kJ/kg.K
(Answer: 0.995 MMSCFD)

4. Tinjau produksi steam pada suatu boiler menggunakan flue gas sebagai sumber energi. Air masuk
boiler pada 100℃ dan steam keluar boiler pada 100℃, x=100%. Setelah melewati boiler,
temperatur flue gas turun dari 1100℃ menjadi 150℃. Heat capacity flue gas sebagai fungsi
temperatur:
𝐶𝑝
= 3,83 + 0,000551 𝑇(𝐾)
𝑅
Kalor penguapan air = 2257 kJ/kg. Dengan menggunakan temperatur lingkungan 25℃ sebagai
referensi, tentukan (a)ΔSgas dan ΔSsteam (b) besarnya maximum work yang dapat diperoleh jika
steam mengalami kondensasi menjadi saturated liquid (dalam kJ/kg steam)
(Answer: (a) ΔSgas=-41.835 kJ/K.mol gas, ΔSsteam=6.048 kJ/K.kg steam (b)-453.6 kJ/kg steam)

5. Tentukan ΔH dan ΔS liquid water dari perubahan 1 bar 25℃ ke 1000 bar 50℃. Data air: