Professional Documents
Culture Documents
Customer: PETRONAS CHEMICALS FERTILISER SABAH SDN BHD 1. Velocity vibration at all measurement points seems within acceptable
Plant: SAMUR limit, however there are some elevated of bearing fault frequencies.
Event Date: 3/2/2021 2. Acceleration envelope (g’s) reading that use to evaluate bearing
Event Type: Ad-Hoc Vibration Measurement & Analysis condition shows trending up level at the motor bearings with Fault
Equipment ID: K-39-91 P2 level.
Report Date: 5/2/2021 3. The envelope reading predominantly by non-synchronous peaks which
are the bearing fault frequencies with amplitude modulation waveform
shows the bearing condition should getting attention.