General Information Technical Assessment

Customer: PETRONAS CHEMICALS FERTILISER SABAH SDN BHD 1. Velocity vibration at all measurement points seems within acceptable
Plant: SAMUR limit, however there are some elevated of bearing fault frequencies.
Event Date: 3/2/2021 2. Acceleration envelope (g’s) reading that use to evaluate bearing
Event Type: Ad-Hoc Vibration Measurement & Analysis condition shows trending up level at the motor bearings with Fault
Equipment ID: K-39-91 P2 level.
Report Date: 5/2/2021 3. The envelope reading predominantly by non-synchronous peaks which
are the bearing fault frequencies with amplitude modulation waveform
shows the bearing condition should getting attention.

Event Description Recommendation


Based on monthly CBM routine, the K-39-01 P2 unit has been put into - Equipment may continue to operate however bearing replacement
watchlist due to trending of acceleration envelope data and abnormal should be plan in the next opportunity.
spectrum pattern suspected bearing defect. - Grease the motor bearing in the correct amount necessarily to prolong
On 3rd February 2021, a confirmation survey was attended with the intention the bearing until next bearing replacement.
to confirm the machines that has been put into our watchlist and attention.
The K-39-01 P2 bearings has been confirmed are within defect stage.
Figure 1- Last measurement overall data value
Figure 2: Motor NDE Acceleration Envelope data
Figure 3: Motor DE acceleration envelope data