Professional Documents
Culture Documents
Customer: PETRONAS CHEMICALS FERTILISER SABAH SDN BHD 1. Highest velocity vibration on the motor unit with 8.8 mm/s at motor
Plant: SAMUR NDE in the vertical direction predominantly by non-synchronous peaks
Event Date: 23/2/2021 with harmonics.
Event Type: Ad-Hoc Vibration Measurement & Analysis 2. High envelope acceleration level predominantly by non-synchronous
Equipment ID: K-13-01-PM2 frequency.
Report Date: 23/2/2021 3. Motor bearing number were included in the spectral data and found
that non-synchronous frequency mainly contributed by bearing fault
frequency, indicating the motor bearing experiencing severe defect.