Professional Documents
Culture Documents
Manual (operators)
LIMITS OF USE
REFUSAL:
Penetration speed < 50 mm / min
Or big rebound effect
+ 45°C + 113°F
OUTDOOR TEMPERATURE range
during operation
- 20°C - 4°F
For very low temperatures,
PTC can propose a special kit
LIMITS OF USE
MAXIMUM allowable
TEMPERATURE on the
gearbox casing and bearing 90°C
covers = 90 °C / 194 °F MAX
Kit level 1
(Snorkel)
Kit level 2
SAFETY
SAFETY
DO NOT LEAVE a
vibrodriver
clamped on a pile
without a safety
sling suspended
to the crane
SAFETY
Safety distance:
Observe a safety distance when
using vibration (recommendation: 8
meters)
SAFETY - HAZARDS
SECURITE – identification des dangers
High pressure hydraulic circuits:
Keep away from pressurized parts. Depressurize the circuit
and wait for the oil to cool before any intervention
Risk of crushing:
Never leave your hands between the jaws of the
clamps, and between the clamps, and in the area
where the clamps slide on the tees
HIGH TEMPERATURE on
the gearbox
FLAMMABLE
liquids PRESSURIZED circuit
ELECTRICAL
Circuits
Clean up Every 08
regularly H Every 08
H
Every
50 H
Every
8H
Every
8H
Every 48
H
Every
8H
Every
48 H
Every
250 H
Every
250 H
Every
8H
.
Every
48 H
Clean up Every
regularly 48 H
Every
Every 48 H
8H
OIL FOR THE GEARBOX
Standard oil supplied by PTC:
TOTAL CARTER SH 220
Important points:
- Oil for lubrication of
gearboxes, gears, bearings
- Synthetic
- High temperature
resistance
- High loads resistance
- Compatible with seals and
metals
Clean up Every
Every 8H
8H
regularly
Every
Every 48 H
48 H
Every
8H
Every
48 H
Clean up
regularly
Every
8H
Every
48 H
Every Every Clean up
8H 48 H
regularly
Every
48H
Every
8H
Every
250 H Every
8H
Every
8H
Every
8H
Every
8H
Every Every
8H 48 H
Every Every
100 H 8H
TROUBLESHOOTING
Failures Failures location Solution
The control panel does not light Emergency Stop Check that none of the
up. "Emergency Stop" buttons is
Battery depressed
Check that the battery cut-off is set
to "Contact".
The Diesel engine is not turning Fuel Check that the fuel level is
Sufficient
Suction valves Check that all suction valves are
open.
The clamps are not closing. Hoses Check the clamp pressure
The clamps are not opening. Control box Check that the hoses are not
inverted.
Check that the green lamp lights up.
The Vibrodriver does not vibrate Clamping head Check if the clamping head is closed.
Check the pressure level in the main
Main pump circuit.
Check that the pump is flowing.
Failures Failures location Solution
The clamping head is slipping Hydraulic circuit Check the pressure
from the profile. Check that there is no leak
Jaws Check the state of the jaws
The Vibrodriver is overheating Vibratory gearbox Implement stops of 15
Excessively minutes per
hour.
Check the oil level of the
Vibratory
gearbox.
Check the operation of the
lubrication pumps.
Stop the Vibrodriver if the
flange temperature exceeds
90°C.