Professional Documents
Culture Documents
SecoRMU-EN-07 12 2011
SecoRMU-EN-07 12 2011
Industrial Solutions
The company traces its beginnings from Thomas A. Edison, who established the Edison Electric Light Company in 1878.
In 1892, a merger of Edison General Electric Company and Thomson-Houston Electric Company created the General
Electric Company. GE is the only company listed in the Dow Jones Industrial Index today that was also included in the
original index in 1896.
Industrial Solutions
GE Industrial Solutions – a division of GE Energy Group, is a global leading provider in power distribution, offering a wide
range of products which include medium and low voltage power distribution equipments and components, and motor &
control systems that are safe, reliable and offer high performance. Its innovative solutions can improve energy
efficiency and environmental impact in power plants, power grids, oil & gas, mining, industrial manufacturing, rail
transportation, commercial buildings, residential houses, alternative energy and many other industries.
2008 World’s Most Respected Companies 2007 World’s Best R&D Companies
Applications
SecoRMU is a compact, modularized, extendable gas insulated ring main unit with all the primary conductive system sealed in a stainless
SF6 gas tank, providing customers a reliable, high-performance and cost efficient product, helping customers to reduce the operating and
maintenance cost.
SecoRMU series ring main units provide integrated solutions for most switching applications in 12kV/17.5kV/24kV distribution networks.
1
General
2
Modular Design/Completely Sealed/Free Extendable Enviroment independent
SecoRMU is a new generation of compact modular SecoRMU is a pressure-sealed system that all the primary
switchgear, with a 3mm high-quality stainless steel tank conductive system is sealed in SF6 gas tank and independent
containing all live parts and switching functions. The gas tank of environmental influence, such as dew, dust, salt fog, small
is filled with SF6 gas, and is manufactured by laser welding animals, chemical substances, etc. Therefore, it reaches
process. The structures of the entire series include individual- the real maintenance free and can be used in various
gas tank and common-gas tank type. Each unit has its severe conditions. SecoRMU has strong ability to prevent
independent function and metal enclosure, and is extendable flooding. Both the gas tank and fuse compartment reach
to the left or right freely. IP67 protection grade. SecoRMU not only makes the power
distribution system more reliable, but also helps to reduce
The combination and extension of SecoRMU series ring main the operation and maintenance cost.
units are simple and reliable, while the cable connection is
also safe and convenient.
Environmental Conditions
Ambient temperature -25°
C~+40°
C
Altitude above sea level ≤1000m (When equipment is to be installed at more than 1000m above sea level, please contact GE.)
Special conditions:
In accrodance with IEC60694, the manufacturer and end-user must agree about special operating conditions which deviate from operation under normal conditions.
The manufacturer/supplier must be consulted in advance if especially severe operating conditions are involved.
Standards
SecoRMU is manufactured and tested in accordance with the latest version of:
High-voltage switchgear and controlgear – Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1kV and up to
IEC62271-200
and including 52 kV
IEC60265-1 High-voltage switches – Part1: Switches for rated voltages above 1 kV and less than 52 kV
IEC62271-100 High-voltage switchgear and controlgear – Part 100: High-voltage alternating-current circuit-breakers
IEC62271-105 High-voltage switchgear and controlgear – Part 105: Alternating current switch-fuse combinations
IEC62271-102 High-voltage switchgear and controlgear – Part 102: Alternating-current disconnectors and earthing switches
IEC62271-1 The Common specifications for high-voltage switchgear and control gear standards
IEC 60694 Common specifications for high voltage switchgear and controlgear standards
3
Product type
SER - □ - □ / □ □ □
Cable's entrance or exit mode
L: left entrance-exit R: right entrance-exit
LR: both sides entrance-exit NA: non entrance-exit
Extension mode
I: left extendible D: right extendible
ID: both sides extendible NA: not extendible
Rated current
630: 630A rated current
Rated voltage
12: 12kV rated voltage 17: 17.5kV rated voltage 24: 24kV rated voltage
Product type
For example:
SER-V-12/630ID is a vacuum circuit breaker unit with 12kV rated voltage and 630A rated current, both sides extendible.
SecoRMU-KKT-12/630 is a three-unit common-tank ring main unit, made of two load switch units and one load switch-fuse
combined unit, with 12kV rated voltage and 630A rated current, not extendible.
4
SecoRMU Configurations
Pressure Gauge Gas Tank Bus Extension
Operating Mechanism
Metering Busbar Extension
Compartment
Fuse Compartment
Gas Tank
Operating Mechanism Pressure Relief
Device
Fuse Compartment
Enclosure
Cable Bushing
Advanced Design
Integrated Fuse Compartment:
Cast three-phase entrance/exit terminals and fuse compartment together, arranged in the form of △, not only compact in
structure, but also easy for assembly.
Modular Design:
The basic functional module units include load break switch unit, switch fuse unit, vacuum circuit breaker unit, bus tie unit, etc.
Each unit is extendible, and uses bus connector for expansion. Dimensions of all load break switch units, switch fuse units, vacuum
circuit breaker units, bus tie units are 350×800×1380mm (width×depth×height).
The load break switch unit and the switch fuse unit can combine together freely to form a common-tank unit. One common gas
tank can accommodate 5 modules at most, while any of which is the same with the basic individual functional unit in the internal
structure and performance.
5
Advanced Manufacturing Equipment and Process
CNC Epoxy Resin Pressure Molding CNC Silicon Rubber Pressure Molding
The epoxy resin insulation components, such as SecoVac-R The silicon rubber insulation components, such as busbar
vacuum circuit breaker, fuse compartment, cable bushing, connector, cable bushing, terminal plug cover, etc., are
busbar connector pedestal, insulator, etc., are produced produced by the Switzerland NC VOGEL mixture of silicone
by Germany NC HEDRICH vacuum resin mixture / pressure rubber / pressure molding system.
molding system, ensuring perfect insulation performance.
6
Technical Data
12/17.5/24kV SecoRMU Rating and electrical performance
Load Break Vacuum Circuit
ITEM Unit Switch Fuse Unit Bus Tie Unit
Switch Unit Breaker Unit
Rated lightening impulse withstand voltage (peak) kV 125 125 125 125
Electrical Endurance Capability class - E2 for load switch E2 for load switch E2 for breaker E2 for load switch
Enclosure IP3X
IP Degree
Gas tank IP67
(1)* Depending on the current rating of the fuse-link. Please refer to transformer-fuse selection table in page 14.
7
SecoRMU Standard Modules
SER-K - Three position load break and - Left/right entrance or exit cable Used for connecting
Load switch unit earthing switch - Left/right extendible or disconnecting the
- Spring operating mechanism - Electrical operating mechanism incoming/outgoing
- Switch position indication for DC24/48/110/220V, cable to the busbar,
load break switch and earthing AC110/220V grounding the three-
switch - Short circuit and earth fault phase cable, as well as
- Potential indicator indicator having the capacity of
- SF6 gas pressure Gauge - Ring CT and ampere meter making the short circuit
- 630A bus bar - Arrester current.
- Earthing bar - Cable terminals
- Interlock between the earthing - Auxiliary switch for load break
switch and the door/operation switch position
8
SER-T Load switch-fuse combined unit
Type
Scheme Standard Features Optional Features Remark
Dimension/Weight
SER-T - Three position switch-fuse- - Left/right entrance or exit cable Used for controlling
Load switch-fuse disconnector with upstream - Left/right extendible and protecting
combined unit earthing switch mechanically - Electrical operating mechanism 1250KVA and below
linked with downstream earthing DC24/48/110/220V, transformers.
switch AC110/220V (For 1600 kVA and
- Spring operating mechanism - Opening coil above transformers,
- Switch position indication for DC24/48/110/220V, please contact GE).
switch-fuse-disconnector and AC110/220V
earthing switch - Short circuit and earth fault
- Fuse compartment indicator
- Potential indicator - Ring CT and ampere meter
- SF6 gas pressure Gauge - Arrester
SER-V - Three position disconnector and - Left/right entrance or exit cable Used in circuit
Vacuum circuit breaker earthing switch - Left/right extendible protection, motor
unit - 630A vacuum circuit breaker - Electrical operating mechanism of protection and
- Operating mechanism of the vacuum circuit breaker transformer protection.
vacuum circuit breaker DC24/48/110/220V,
- Mechanical interlock and position AC110/220V
indicator for vacuum circuit - Closing coil
breaker and three position DC24/48/110/220V,
disconnector and earthing switch AC110/220V
- Potential indicator - Opening coil
- SF6 gas pressure Gauge DC24/48/110/220V,
- 630A bus bar AC110/220V
350×800×1380 - Earthing bar - Ring CT and ampere meter
9
SER-B Bus Tie Unit
Type
Scheme Standard Features Optional Features Remark
Dimension/Weight
SER-B - Two position load break switch - Left/right entrance or exit Used for busbar
Bus tie unit - Operating mechanism cable coupling.
- Switch position indicator - Left/right extendible
- SF6 gas pressure Gauge - Electrical operating
- 630A bus bar mechanism of load break
- Panel padlock device switch
DC24/48/110/220V,
AC110/220V
- Auxiliary switch for load break
switch position
3NO+3NC
350×800×1380
(width×depth×height)
/160kg
SER-V+SER-C1 - Three position disconnector and - Electrical operating mechanism of Used as a tie breaker.
Vacuum circuit breaker earthing switch vacuum circuit breaker
& Bus tie unit - 630A vacuum circuit breaker DC24/48/110/220V,
- Operating mechanism of the AC110/220V
vacuum circuit breaker - Closing coil
- Mechanical interlock and position DC24/48/110/220V,
indicator for vacuum circuit breaker AC110/220V
and three position disconnector and - Opening coil
earthing switch DC24/48/110/220V,
- Potential indicator AC110/220V
- SF6 gas pressure Gauge - Ring CT and ampere meter
- 630A bus bar - Auxiliary switch for disconnector
700×800×1380 - Earthing bar position
(width×depth×height) - Interlock between the earthing 2NO+2NC
/300kg switch and the door/operation shaft - Auxiliary switch for earthing switch
- Operating mechanism interlock position
between vacuum circuit breaker 1NO+1NC
and disconnector - Cable terminal used for busbar
- Cable bushings with integrated coupling
sensors
- Panel padlock device
- Relay and protection CT
10
SER-C Bus bar lift unit
Type
Scheme Standard Features Optional Features Remark
Dimension/Weight
SER-C - 630A bus bar - C1 Air insulated adopted Used for incoming
Bus bar lift unit - Potential indicator - C2 SF6 gas insulated adopted or outgoing cable
- Earthing bar connection.
350×800×1380
(width×depth×height)
/100kg
SER-M - 630A bus bar - Three current Used for electric power
Metering unit - Two current transformers measurement.
transformers - Three potential
- Two potential transformers
transformers - Arrester
- Fuse for protecting PT - A watt-hour meter
- Potential indicator - A var-hour meter
600×800×1380
(width×depth×height)
/180kg
V
V
11
SER-PT PT unit
Type Standard
Scheme Optional Features Remark
Dimension/Weight Configuration
600×800×1380
(width×depth×height)
/180kg
12
Common-tank Ring Main Units
SecoRMU provides economic schemes of putting multi units into a common tank. One common SF6-tank can accomodate
maximum 5 modules combined freely. Each ring main unit is extendible, as well as capable of splicing with other individual-gas
tank or common-tank ring main units.
13
SecoRMU
Common-tank Ring Main Units Schemes
No. Type Primary Schematic Diagram Dimensions (mm)
1 SER-KK 700×800×1380
2 SER-KT 700×800×1380
3 SER-CK 700×800×1380
4 SER-CT 700×800×1380
5 SER-CV 700×800×1380
6 SER-VV 700×800×1380
7 SER-KKK 1050×800×1380
8 SER-KKT 1050×800×1380
9 SER-KTK 1050×800×1380
10 SER-KTT 1050×800×1380
11 SER-KKKK 1400×800×1380
12 SER-KTTT 1400×800×1380
14
No. Type Primary Schematic Diagram Dimensions (mm)
13 SER-KKTT 1400×800×1380
14 SER-KTKT 1400×800×1380
15 SER-KKKKK 1750×800×1380
17 SER-KTTTT 1750×800×1380
18 SER-KKKKT 1750×800×1380
19 SER-KKKTT 1750×800×1380
20 SER-KKTTT 1750×800×1380
15
Protection
Transformer/Line Protection
Φ76
442
13.8 6 10 16 20 25 32 32 50 50 50 63 80 /
15~17.5 6 10 16 20 25 25 32 40 50 50 63 80 /
20~24 6 10 10 16 16 20 25 32 40 40 40 50 80
16
Protected by a VCB combined with relays
When using vacuum circuit breaker for transformer and line protection, WIC1 CT-powered protection relay of SEG company can
be used to provide protection against short circuit, over-current and grounding fault.
The WIC1 is a CT-powered protection relay with minimal space requirement which complies with the highest demands on a digital
protection device. It also has simple but safe wiring, and high electromagnetic interference immunity.
SecoRMU can be delivered with other protection relays according to customers' requirements. As an option, GE MIFII can be fitted
in the low voltage compartment on top of the switchgear, and powered by external power supply.
17
SecoRMU Accessories
Busbar Connector
End Plug Special designed for ring main unit's expansion and
Terminal plugs are used for sealing the end terminal of the connection, the busbar connectors have compact structures
ring main units on both sides. and small connecting resistances. With them, the connection
between ring main units is realiable and convenient. The
busbar connector, with the shape of inner cone, adopts
shielded silicon rubber to fully seal and insulate the
interconnecting busbar and terminal busbar bushing.It also
can be reserved for future expansion.
Fault Indicator
The capacitive voltage indicator can display whether the bus 268
100
or cable is live. The port on the bottom of the indicator is used
for checking different phase. Short-circuit and grounding
fault indicator can also be installed to locate the faults.
Cable Connector
Applicable standards: EN50181 DIN47636
- Shielded type (touchable), non-shielded type (untouchable)
- Front-plug cable connector, rear-plug cable connector, rear-
plug lightning conductor
- Cross section of cable: 35mm2×400mm2
Pressure Gauge - A standard unit can be connected to at most 2 cables (Front-
Each gas tank is equipped with a pressure gauge in the front plug cable connector + rear-plug cable connector, or front-
panel, observing SF6 gas pressure, in order to ensure the plug cable connector + rear-plug arrester). If 3 cables or
safety and reliability of the operations. more is required (non-standard panel), please contact GE.
18
Outdoor Switching Substation
The outdoor ring main unit substation adopts metal-enclosed prefabricated structure, with excellent mechanical strength. Its
protection degree can reach IP33, which protect the machine against the harmful effects due to the ingress of water and solid
foreign objects (like small animals).
Ventilation:
The shutters can be opened symmetrically on the
left and right, up and down. The panes are lined with
removable good-quality thin net plates.
Thermal Insulation:
The roof is lined with double-layer high-quality heat
insulation foam.
Anti-condensation:
The slope of the roof is designed more than 3°. The
big roof cover, as well as good ventilation, prevent the
switching substation from condensation.
19
SecoRMU Typical Solutions
Typical ring power supply system
Terminal user
20
SecoRMU Dimension and Installation Foundation
Dimension and installation foundation of individual ring main unit
800
Unit K T V B C M PT P
25 720
A 350 600
D 300 550
2SHUDWLQJPHFKDQLVPFRPSDUWPHQW
Pressure release channel
868
50.5 50.5
100
≥800mm suggested
545
720
6HFWLRQYLHZRIFDEOHWUHQFK
21
Installation foundation of outdoor switching substation
Front side
770
1200
Back side
Bottom view
2400 1200
2300
10# channel steel
Operating
350 350 350 350 600 800
mechanism
3mm above the ground compartment
Gas tank
Back Front
1750
1675
1750
A-A view
K T K T PT On left and right
Entry cover plate 95
148.5 10# channel steel
550 1200 290 Ladder
2420 960
A-A 2080 30 980
302
1840 1540
750
Angle steel for cable fixation
1685
1685
1990
1482
22
SecoRMU Requirement Datasheet
Project Tel
Address Fax
Quantity
Quantity
Operating Voltage of
DC24V□ DC48V□ DC110V□ DC220V□ AC110V□ AC220V□
Electric Mechanism
No.
Type①
Extension Mode②
Fuse Current④
Cable Connector⑤
Quantity (Set)⑥
Operating
CT/ PT Relay Protection
Mechanism
Remark
Manual
Electric
2CT/2PT
3CT/3PT
WIC1
MIFII
1 K □ □ / □ □ / /
2 T □ □ □ □ □ /
3 B □ □ / / / / / /
4 V □ □ / □ □ / □
5 C / / / □ □ / / /
6 M / / / □ □ / / /
7 PT / / / □ □ / / /
8 P / / □ □ / /
No.
Type①
Extension Mode②
Fuse Current④
Cable Connector⑤
Quantity (Set)⑥
Operating
CT/ PT Relay Protection
Mechanism
Remark
Manual
Electric
2CT/2PT
3CT/3PT
WIC1
MIFII
K □ □ / □ □ / /
9
T □ □ □ □ □ /
C / / / □ □ / /
10
T □ □ / □ □ □ /
23
No.
Type①
Extension Mode②
Fuse Current④
Cable Connector⑤
Quantity (Set)⑥
Operating
CT/ PT Relay Protection
Mechanism
Manual Remark
Electric
2CT/2PT
3CT/3PT
WIC1
MIFII
K □ □ / □ □ / /
11 K / / □ □ / □ □ / /
T □ □ / □ □ □ /
K □ □ / □ □ / /
K / / □ □ / □ □ / /
12
K / / □ □ □ □ □ /
K □ □ □ □ □ /
K □ □ / □ □ / /
K / / □ □ / □ □ / /
13 T / / □ □ □ □ □ /
T / / □ □ □ □ □ /
T □ □ □ □ □ /
Optional Accessories
Note①: 1) K – Load switch unit; T - Load switch-fuse combined unit; B - Bus tie unit; V - Vacuum circuit breaker unit; C - Busbar lift
unit; M - Metering unit; PT – PT unit.
2) Common-tank ring main unit is combined freely by individual C, T or K ring main unit. A common-tank RMU can be
assembled by maximum 5 individual units.
Note②: Please remark the extension mode of the RMU products. Remark "D" if it's right extendible. Remark "I" if it's left extendible.
Remark "ID" if it's both sides extendible. Remark "\" if it's not extendible.
Note③: Please remark the cable's entrance or exit mode if the RMU is connected by cable. Remark "R" if it's right entrance-exit.
Remark "L" if it's left entrance-exit. Remark "LR" if it's both sides entrance-exit. Remark "\" if there is no entrance-exit cable.
Note④: Please refer to transformer-fuse selection table (shown in page 14) for reference.
Note⑤: Please remark the specifications (such as size, type etc.) of the cable connector.
Note⑥: Example: please fill the blank of quantity item "9" if the scheme is P+K+M+TT+B+TT+M+K+P.
24
GE Energy
Industrial Solutions
GE Asia Headquarters
China 11F, Akasaka Park Bldg.,5-2-20 240 Tanjong Pagar Road
4F, Building 2, CTP, No.1 Hua Tuo Rd. Akasaka Minato-ku, Tokyo #06-00 GE Tower
Zhang Jiang Hi-Tech Park 107-0052 Singapore 088540
Pudong, Shanghai 201203 T: +81 3 5544 6780 T : +65 6326 3404
T : +86 21 3877 7888 F: +81 3 3589 3372 F : +65 6326 3015
F : +86 21 3877 7600
BRI II Tower, 27th floor Level 6, 1 Sentral, Jalan Travers, 7th Floor, Capital Tower, All Seasons Place
Jl. Jend. Sudirman No. 44-46 Kuala Lumpur 50470 87/1 Wireless Road, Lumpini
Jakarta 10210 T : +603 2273 9788 Pathumwan, Bangkok 10330
T: +62 21 573 0430 F : +603 2273 3481 T : +66 2 648 0199
F: +62 21 574 7089 F : +66 2 648 0100