You are on page 1of 33

Installation Manual

Exit Device

ASSA ABLOY Hospitality 1


Copyrights
The information in this document is subject to change at the sole discretion of
ASSA ABLOY without notice.

Any use, operation or repair in contravention of this document is at your own risk.
ASSA ABLOY does not assume any responsibility for incidental or consequential
damages arising from the use of this manual.

All information and drawings in this document are the property of ASSA ABLOY.
Unauthorized use and reproduction is prohibited.

VingCard and Elsafe are registered trademarks of ASSA ABLOY.

ASSA ABLOY Hospitality 2


Table of contents
1. Introduction
.................................................................................................5

2. Dimensions
.................................................................................................6
2.1 Dimensions
............................................................................................................................
for rim version 6
2.2 Dimensions
............................................................................................................................
for rod version 7
2.2.1
................................................................................................................................................
Top strike for rod version 7
2.2.2
................................................................................................................................................
Bottom strike for rod version 7
2.3 Outside
............................................................................................................................
escutcheon 7

3. System
.................................................................................................8
components
3.1 Components
............................................................................................................................
in outside escutcheon 8
3.2 Components
............................................................................................................................
in outside escutcheon 9
3.3 Components
............................................................................................................................
in rod version of exit device 10
3.3.1
................................................................................................................................................
Components in glass bead shim kit 11
3.3.2
................................................................................................................................................
Components in rod extension kit 12

4. Installation
.................................................................................................13
4.1 To
............................................................................................................................
prepare the outside escutcheon 13
4.2 Preparing
............................................................................................................................
the battery cable in the push bar 14
4.3 To
............................................................................................................................
install the exit device, rim version 15
4.4 To
............................................................................................................................
install the exit device, rod version 17

5. To.................................................................................................18
check the installation
5.1 Mechanical
............................................................................................................................
check 18
5.2 Functional
............................................................................................................................
check 18

Appendix
.................................................................................................19
A: Outside template for card reader

Appendix
.................................................................................................20
B: Inside template for exit device

Appendix
.................................................................................................21
C: RFID 3G exit device
Exploded
............................................................................................................................
view and component list 21
RFID
............................................................................................................................
3G specific parts 21
Dimensions
............................................................................................................................
in mm (inches) 22
To mount
............................................................................................................................
the upgrade plate 22
Cable
............................................................................................................................
connection 23
To remove
............................................................................................................................
the front cover 23

Appendix
.................................................................................................24
D: Endnode kit
Parts
............................................................................................................................ 24

ASSA ABLOY Hospitality 3


Mounting
............................................................................................................................
procedure 25

Appendix
.................................................................................................28
E: BLE exit device
Parts
............................................................................................................................ 28
Mounting
............................................................................................................................
procedure 29

Revision
.................................................................................................32
history

ASSA ABLOY Hospitality 4


1. Introduction

This manual describes


dimensions for parts
description of rim version and rod version of exit device with additional parts
installation procedures
installation check list
information about RFID 3G specific parts
information about endnode kit (only applicable for Visionline)
information about BLE (Bluetooth® Low Energy)

The exit device combines the electronic card lock with a push bar from Sargent.
This makes it possible to use encoded cards to control all guest and staff access to
the building, and at the same time provide a panic exit device to satisfy all safety
considerations for emergency exit. Opening the door from the inside is achieved
by simply pushing the push bar.

The exit device is suitable for wood, metal and glazed doors. It is supplied in
two versions:
rim version with latch on the side of the door; for horizontal installation
rod version with latch on top and bottom of the door; for vertical installation

Figure 1: Rim version of exit device

Figure 2: Rod version of exit device

ASSA ABLOY Hospitality 5 66 1000 007-4


2. Dimensions

There are two standard lengths for the horizontally installed push bar;
92 cm (3'') can be cut to fit other door width, min. 82 cm (3'')
122 cm (4'') can be cut to fit other door width, min. 92 cm (3'')

Figure 3: Push bar

Figure 4: Dimensions of escutcheon and exit device in mm (inches)

2.1 Dimensions for rim version

Recommended heights of centerline:

Exit device 1008 mm (4'') above finish floor


Escutcheon handle 976 mm (39 3/4'') above finish floor
Table 1: Dimensions for rim version

ASSA ABLOY Hospitality 6 66 1000 007-4


2.2 Dimensions for rod version

Standard length for up to 213 cm (84'') doors


A rod extension kit needs to be ordered for door heights from 213 cm (8'')
to 259 cm (10 13/64'')

2.2.1 Top strike for rod version


Dimensions in mm (inches):

Figure 5: Top strike 'J'


mounted on header of the door

2.2.2 Bottom strike for rod version


Dimensions in mm (inches):

Figure 6: Bottom strike 'K' mounted on floor

2.3 Outside escutcheon

The exit device is designed for flush-mounting on the door; see a picture of the
escutcheon and its dimensions in Figure 4. For the rod version of the exit device,
a glass bead shim kit is available for doors with glass beads or raised molding with
a height of no more than 6 mm (¼''). See section 3.3.1 for detailed information.

ASSA ABLOY Hospitality 7 66 1000 007-4


3. System components

The outside escutcheon set includes an LCU (lock controller unit) and an
electromechanical lock mechanism. The LCU is powered by a 4.5V or 9V
battery (9V for older installations only) that is located inside the push bar
behind the battery cover plate; see Figure 8 for rim version and Figure 9
for rod version.

The exit device is released mechanically from the inside by pushing on the bar.
The door is unlocked from the outside by using a valid key card. The LCU will
accept cards programmed in the Visionline, VingCard Vision or 2100 system.

3.1 Components in outside escutcheon

Figure 7: Components in outside escutcheon

Pos Description
A Protector plate
B Battery cable
C Lock case
D LCU; lock controller unit
Table 2: Components in outside escutcheon

ASSA ABLOY Hospitality 8 66 1000 007-4


3.2 Components in rim version of exit device

Figure 8: Components in rim version of exit device

Pos Description
1 Push bar
2 Lock chassis
3 Strike plate
4 Lock chassis cover
5 Outside escutcheon
6 End cap
7 Adapter plate
8 Battery cover plate
Table 3: Components in rim version of exit device

ASSA ABLOY Hospitality 9 66 1000 007-4


3.3 Components in rod version of exit device

Figure 9: Components in rod version of exit device

Pos Description
A Top latch chassis
B Top latch cover
C Rod guides
D Lock chassis
E Bottom latch cover
F Bottom latch chassis
G Push bar
H End cap
I Lock chassis cover
J Battery cover plate
K Outside escutcheon
L Adapter plate
Table 4: Components in rod version of exit device

ASSA ABLOY Hospitality 10 66 1000 007-4


3.3.1 Components in glass bead shim kit
On doors with raised molding or glass beads, a special glass bead shim kit 12-587
(see arrows in Figure 10) must be used between the devices and the door.
the kit consists of two sets of 3 mm shims
maximum thickness is 6 mm (1/4)''
available in PEN and PEB finishes

Figure 10: Glass bead shim kit

Note: Since the thickness of the adapter plate is 3 mm (1/8 ''), one shim set 3 mm
(1/8 '') must always be used for rod guides, top strike chassis and bottom strike
chassis. Shim for lock chassis should not be used.

Figure 11: Adapter plate

ASSA ABLOY Hospitality 11 66 1000 007-4


3.3.2 Components in rod extension kit

For installations of an exit device with rod, be aware when the door height exceeds
2133 mm (84''); in these cases, a rod extension kit must be used. The rod extension
kit can be ordered in the following lengths:
150 mm (6'')
300 mm (12'')
450 mm (18'')

Figure 12: Rod extension kit

ASSA ABLOY Hospitality 12 66 1000 007-4


4. Installation

4.1 To prepare the outside escutcheon


1. Make sure that the protector plate is mounted onto the lock case; see Figure 7.
2. Make sure that the label on the handle spindle is facing upwards; label marked
RO or LO. If this is not the case, turn the spindle until it stops with the
label upwards.
3. For correct positioning of the exit device at the door, see the applicable one
of section 2.1 (rim version) and 2.2 (rod version).
4. Machine the door according to the provided templates; see Appendix A
(outside template for card reader) and Appendix B (inside template for
exit device).
5. Mount the outside escutcheon to the adapter plate with the four machine screws
provided, and make sure to pull the LCU battery cable through the 20mm (25/32)''
hole in the adapter plate; see Figure 15.

Figure 13: Cut-out, Figure 14: Cut-out,


push bar side outside escutcheon

Figure 15: Figure 16:


Adapter plate Outside escutcheon

ASSA ABLOY Hospitality 13 66 1000 007-4


4.2 To prepare the battery cable in the push bar
In many cases, the batteries are placed inside the push bar but also other
locations are possible. See pictures below for information on how to proceed
with the battery cable.
1. Insert the battery cable in the
push bar; make sure that the
connector is facing upwards
in the guide groove. Only the
connector and the dismantled
part of the cable will be seen.

Figure 17

Figure 18

2. Push the cable into the guide


groove while the push bar is
depressed. The cable will follow
the guide groove. When the
battery cable is slided all the
way through the rail, release
the push bar.

Figure 19

ASSA ABLOY Hospitality 14 66 1000 007-4


4.3 To install the exit device, rim version

Note: See section 3.2 for exploded view and component list of the exit device in
rim version.
1. Mount the lock chassis (B)
on the adapter plate with the
machine screws provided, and
make sure to pull the battery
cable through the hole in the
lock chassis.

Figure 20

2. Mount the push bar (A)


on the lock chassis (B) with
the machine screws provided.
3. Connect the battery cable
from the push bar to the
cable from the LCU.
Figure 21

4. Strap the battery cable


to the chassis.

Figure 22

ASSA ABLOY Hospitality 15 66 1000 007-4


5. Level the push bar and mount the end cap
bracket (F) on the 3 mm (1/8’’) shim plate
with the screws provided.
6. Connect the battery cable to the battery
and press the battery cover plate onto the rail.
7. Hook up the battery cable inside the push bar.
8. Install the strike plate (C).

Figure 23
9. Install the cover (D) for the lock chassis
(see Figure 24), and the cover for the end cap
(see Figure 25).
10. Make sure that the push bar releases the
lock mechanism; see section 5.1 Mechanical
check for details.
11. Load the applicable lock firmware into the
LCU using a service device with Lock Service/
Lock Service 3G (see Quick reference guide
Lock Service or Quick reference guide Lock
Service 3G).
12. Test for proper card operation; see section 5.2
Functional check for details.

Figure 24

Figure 25

ASSA ABLOY Hospitality 16 66 1000 007-4


4.4 To install the exit device, rod version

Note: See section 3.3 for exploded view and component list of the exit device in rod version.

1. Mount the push bar (G) on the lock chassis (D) with the machine screws provided.
2. Connect the battery cable from the push bar to the cable from the LCU.
3. Strap the battery cable to the chassis.

Figure 26

4. Level the push bar and mount the end cap bracket (H) on the 3 mm (1/8)''
shim plate with the screws provided.
5. Mount the top latch chassis (A) on the 3 mm (1/8)'' shim plate according to
the templates delivered with the exit device.
6. Install the top strike according to the templates delivered with the exit device.
7. Mount the cover (B) for the top latch chassis with the screws provided.
8. Mount the bottom latch chassis (F) on the 3 mm (1/8)'' shim plate according to
the templates delivered with the exit device.
9. Install the bottom strike according to the templates delivered with the exit device.
10.Mount the cover (E) for the bottom latch chassis with the screws provided.
11.Install the rod guides (C).
12.Connect the battery cable to the battery and press the battery cover plate onto
the rail.
13.Hook up the battery cable inside the push bar.
14.Install the top and bottom strike plates according to the templates delivered
with the exit device.
15.Install the cover (I) for the lock chassis and the cover for the end cap.
16.Make sure that the push bar releases the lock mechanism; see section 5.1
Mechanical check for details.
17.Load the applicable lock firmware into the LCU using a service device with
Lock Service/Lock Service 3G (see Quick reference guide Lock Service or
Quick reference guide Lock Service 3G).
18.Test for proper card operation; see section 5.2 Functional check for details.

ASSA ABLOY Hospitality 17 66 1000 007-4


5. To check the installation

5.1 Mechanical check

1. Check that the exit device latch goes smoothly into the strike plate
when the door is closed.
2. Check that the push bar moves freely back into position after it has
been depressed.
3. Check that when depressing the push bar, the parts inside the rail
do not inhibit the push bar from movement.
4. Check that the latch can be freely moved in and out from the
exit device chassis.
5. For rod installation: make sure that the vertical rod extension
moves freely when the push bar is depressed.
6. For rod installation: make sure that the latches in the top latch chassis
and bottom latch chassis move freely.
7. For rod installation: make sure that the exit device top latch and/or
bottom latch goes smoothly into the strike plates when the door is closed.

5.2 Functional check

1. Insert a valid key card into the LCU in the outside escutcheon;
the LED will illuminate with a green flash.
2. Enter the room by depressing the handle.

ASSA ABLOY Hospitality 18 66 1000 007-4


Appendix A: Outside template for card reader

Dimensions in mm (inches)

Figure A1

ASSA ABLOY Hospitality 19 66 1000 007-4


Appendix B: Inside template for exit device

Dimensions in mm (inches)

Figure B1

ASSA ABLOY Hospitality 20 66 1000 007-4


Appendix C: RFID 3G exit device

Exploded view and component list

Figure C1: Exploded view of Classic RFID 3G

Note: If upgrading an old exit device installation to RFID 3G, the 9V electronics is kept and 9V (6AA)
batteries are used instead.

RFID 3G specific parts


Pos Description
1 Front escutcheon
2 4823880 RFID 3G module, assy-
3 LCA 6343 (lock case adapter)
4 Lock case for escutcheon
5 Protection
6 Upgrade plate
7 Screw, machine, pan, M5x8
8 Frame
9 Cable ext., 2p IDC 2p IDC
10 Battery cable for exit device
11 Battery holder 4.5V
12 3 batteries, LR6- AA
Table C1: RFID 3G specific parts for exit device

ASSA ABLOY Hospitality 21 66 1000 007-4


Dimensions in mm (inches)

Figure C2

To mount the upgrade plate


Mount the upgrade plate using the mounting brackets normally used for the mag
LCU. The LCA 6343 is to be mounted inside the upgrade plate. Either tape or Velcro
(not included) can be used to fasten the LCA.

Figure C3: To mount the LCA and upgrade plate

ASSA ABLOY Hospitality 22 66 1000 007-4


Cable connection
1. When the RFID 3G module has been mounted on
the front escutcheon, slide the cable from the RFID
3G module through the hole marked with red in
Figure C4.

Figure C4
2. Connect the cables according to Figure C5.
Note: To avoid squeezing the cables, place them
inside the upgrade plate.

Figure C5

To remove the front cover


Press the two wings on top of the cover (marked with arrows in the left picture
below), and at the same time pull the cover according to Figure C6.

Figure C6

ASSA ABLOY Hospitality 23 66 1000 007-4


Appendix D: Endnode kit

Parts
If the exit device should be online (only applicable for Visionline), an endnode kit
must be mounted on the escutcheon according to the instruction Mounting of
endnode kit in this appendix. The endnode kit consists of the parts shown in
Figure D1.
Note: The endnode itself (see Figure D2) is sold separately.

Figure D1: Endnode kit for exit device: Y-cable, endnode holder and screws

Pos Description
1 Y-cable
2 Endnode holder
3 Screw, WN 1423 K25x8
Table D1: Parts included in the endnode kit

Figure D2: Endnode

ASSA ABLOY Hospitality 24 66 1000 007-4


Mounting procedure

1. Before the endnode kit is mounted, the escutcheon


has an end plug which looks as in Figure D3.
2. Use a pliers to remove the end plug.

Figure D3

3. Figure D4 shows the back of the endnode holder.


On top of the holder are the hooks (see close-up in
Figure D5) that should be snapped onto the
escutcheon according to step 4 below.

Figure D4

Figure D5

4. Snap the endnode holder onto the escutcheon in


the direction shown with the blue arrow in Figure
D6. Make sure that the holder snaps into the correct
position.

Figure D6

ASSA ABLOY Hospitality 25 66 1000 007-4


5. Thread the Y-cable from the inside of the escutcheon
through the hole in the endnode holder; place the
endnode in the holder (but do not fasten the
endnode with screws at this point). Connect the
Y-cable to the endnode as shown in Figure D7.

Figure D7

6. Pull the cable protection down so it covers the


escutheon metal, i.e. so that the distance between
contact and cable protection is approximately 15 mm
(19/32)''.

Figure D8

7. Fasten the endnode in the endnode holder with the


two screws that are enclosed with the endnode kit;
a Torx T8 driver is needed.

Figure D9

8. Pull the Y-cable on the same side of the lock case


as where the retaining mechanism (motor) is
located. Figure D10 shows an example where the
retaining mechanism (marked with red) is located
on the left side.

Figure D10

ASSA ABLOY Hospitality 26 66 1000 007-4


Close-up of the motor:

Figure D11

9. The contacts from the Y-cable should be connected


to the LCU and LCA respectively according to
Figure D12.

Figure D12

10. Mount the frame.


11. Connect the battery cable to the contact marked
with red in Figure D13.
12. Mount the escutcheon on the door.

Figure D13

ASSA ABLOY Hospitality 27 66 1000 007-4


Appendix E: BLE exit device
With the Mobile access option set in the Visionline software, the BLE technology
(Bluetooth® Low Energy) is used for exchanging data. Instead of using cards for
access, mobile keys are used. The guest must have a Bluetooth® telephone which
is registered with an Endpoint ID, and an app for opening the door. See Installation
instruction Mobile access option for details about the option. The 3G RFID exit device
can be equipped with a BLE module, and can if desired have a Zigbee endnode at
the same time.

Parts

Figure E1: Classic BLE fixing kit

Pos Description
1 BLE bracket for Classic
2 Upgrade plate BLE
3 Cable assy, double endnode for Signature
4 Label
Table E1: Description of Classic BLE fixing kit

ASSA ABLOY Hospitality 28 66 1000 007-4


Mounting procedure

1. The BLE module should be mounted on the


back of the outside escutcheon. If the outside
escutcheon is already mounted at the door,
remove it from the door so it looks as in
Figure E2.

Figure E2

2. Mount the BLE module in the BLE bracket for


Classic; BLE contact up to the right as shown
in Figure E3.

Figure E3

3. Drag the LCU cable and the cable from the


BLE module through the upgrade plate BLE.

Figure E4

ASSA ABLOY Hospitality 29 66 1000 007-4


4. Snap the BLE bracket for Classic, including
the BLE module, onto the outside escutheon.
5. Screw the upgrade plate BLE into place with
two T20 screws.

Figure E5

Figure E6

6. Connect the LCU cable with the LCU part of


the double endnode cable (see Figure E1 for
the LCU part).

Figure E7

ASSA ABLOY Hospitality 30 66 1000 007-4


7. Connect the cables to LCA 6343:
- Connect the cable from the lock case to the
10-pin connector on the left side of LCA 6343.
- Connect the LCA part of the double endnode cable
to the 7-pin connector on the right side of LCA 6343.
- Connect the cable from the battery holder to the
2-pin connector on top of LCA 6343.
8. Fold all cables into the upgrade plate BLE.
9. If ZigBee is not applicable, mount the
outside escutcheon on the door. If ZigBee
is applicable, first perform steps 10-11
below and then mount the outside escutcheon
on the door.

Figure E8
10. If ZigBee endnode is applicable, an endnode holder
with a ZigBee endnode in it is already mounted at
the bottom of the escutcheon (see Appendix D for
details about the endnode kit and mounting of it).
11. If the outside escutcheon should also be
equipped with a ZigBee endnode, connect
the remaining part of the double endnode
cable to the ZigBee endnode.
Note: Route the double endnode cable that
goes to the ZigBee endnode to the left, i.e.
between the jellyfish and the spacer.
Note: Make sure to drag the cable through
the hole in the endnode holder as shown in
the detail in Figure E10.

Note: If ZigBee endnode is not applicable,


Figure E9 let the connector that should else go to the
ZigBee endnode just stay at the bottom of
the escutcheon.

Figure E10

ASSA ABLOY Hospitality 31 66 1000 007-4


Revision history

Date Change
March 3, 2012 Added RFID 3G incl endnode kit
July 3, 2013 New endnode and Y-cable
January 7, 2015 Added BLE

ASSA ABLOY Hospitality 32 66 1000 007-4


ASSA ABLOY Hospitality APAC
E-mail: apac.hospitality@assaabloy.com
Phone: +65 6305 7670

ASSA ABLOY Hospitality EMEA


E-mail: emea.hospitality@assaabloy.com
Phone: +47 69 24 50 00

ASSA ABLOY Hospitality North America


E-mail: northam.hospitality@assaabloy.com
Phone: +1 972 907 2273

ASSA ABLOY Hospitality Latin America


E-mail: lam.hospitality@assaabloy.com
Phone: +52 55 36 40 12 00

www.assaabloyhospitality.com

ASSA ABLOY Hospitality 33

You might also like