Professional Documents
Culture Documents
Guide Bsi Config User S Guide en 132478
Guide Bsi Config User S Guide en 132478
Document: D5128
Part: D301428X012
December 2014 OpenBSI Version 5.9
Be sure that these instructions are carefully read and understood before any operation is
attempted. Improper use of this device in some applications may result in damage or injury. The
user is urged to keep this book filed in a convenient location for future reference.
These instructions may not cover all details or variations in equipment or cover every possible
situation to be met in connection with installation, operation or maintenance. Should problems arise
that are not covered sufficiently in the text, the purchaser is advised to contact Emerson Process
Management, Remote Automation Solutions for further information.
The customer should note that a failure of this instrument or system, for whatever reason, may
leave an operating process without protection. Depending upon the application, this could result in
possible damage to property or injury to persons. It is suggested that the purchaser review the
need for additional backup equipment or provide alternate means of protection such as alarm
devices, output limiting, fail-safe valves, relief valves, emergency shutoffs, emergency switches,
etc. If additional information is required, the purchaser is advised to contact Remote Automation
Solutions.
When returning any equipment to Remote Automation Solutions for repairs or evaluation,
please note the following: The party sending such materials is responsible to ensure that the
materials returned to Remote Automation Solutions are clean to safe levels, as such levels are
defined and/or determined by applicable federal, state and/or local law regulations or codes. Such
party agrees to indemnify Remote Automation Solutions and save Remote Automation Solutions
harmless from any liability or damage which Remote Automation Solutions may incur or suffer due
to such party's failure to so act.
ELECTRICAL GROUNDING
Metal enclosures and exposed metal parts of electrical instruments must be grounded in
accordance with OSHA rules and regulations pertaining to "Design Safety Standards for Electrical
Systems," 29 CFR, Part 1910, Subpart S, dated: April 16, 1981 (OSHA rulings are in agreement
with the National Electrical Code).
This product contains sensitive electronic components that can be damaged by exposure to an
electrostatic discharge (ESD) voltage. Depending on the magnitude and duration of the ESD, this
can result in erratic operation or complete failure of the equipment. Read supplemental document
S14006 for proper care and handling of ESD-sensitive components.
BSI_Config User’s Guide
What is BSI_Config?
BSI_Config is a free configuration software package, for performing
basic configuration of your ControlWave or Network 3000 controller,
flow computer, or transmitter.
It may be used with the following products:
ControlWave-series controllers
Network 3000-series including: DPC 3330, DPC 3335, RTU 3310,
RTU 3305, and 3530 TeleRTU controllers plus 3530-series
TeleFlow, TeleCorrector, and TeleRecorder flow measurement
products
3808 MVT Transmitter
Rosemount 4088B
For some devices Web_BSI prompts you to enter the local address of
the device. (The default local address is 1.) Then click OK and the
associated web page opens.
For example, if you have created HTML pages for displaying signal
values from the ControlWave (using OpenBSI’s ActiveX controls),
ControlView allows you to connect to the ControlWave, upload the
HTML files to your PC (using FTP), and launch Internet Explorer to
allow you to view the HTML pages with their associated data from the
ControlWave.
Check
“Download
User Files”
when you
download files
to the
ControlView file
area of the
ControlWave’s
flash memory.
The “User Files Path” should follow the format shown below:
\ProgramData\Bristol\OpenBSI\Downloads\project_name\ControlView
Where:
project_name is the basename of the ControlWave project. The folder
containing the files to be downloaded must be a sub-directory of
projectname called ‘ControlView’.
So, for example, if the ControlWave project name is STATION3, then
the folder containing the files to be downloaded to FLASH should be
called:
\ProgramData\Bristol\OpenBSI\Downloads\STATION3\ControlView
IMPORTANT
If the files you are downloading are to be compressed into a zip file, you must include a
STARTUP.INI file within the zip file, which identifies which application should be launched when
the files are unzipped. This file takes the format:
[STARTUP]
File = xxxxx.yyy
Program = program_name
Where:
xxxxx.yyy is the name of one of the zipped files.
program_name is the name of the program to be launched by
ControlView, once the zipped file is
unzipped.* If the directory containing the
program is not part of the standard
Windows™ PATH statement, you must enter
the entire path and filename of the program
executable here.
Example STARTUP.INI File:
[STARTUP]
file=mymenu.htm
program=iexplore
* NOTE: ControlView only uses the ‘program’ entry in the STARTUP.INI file if it is unable
to choose a program based on the Windows™ file association.
Note: Entering an RTU name will only work if, when you select it, that
name can be resolved to an IP address. This means that the node
name must be mapped to an IP address in the Windows™ Hosts
file. This mapping occurs by running LocalView / NetView
when you connect the very first time using a node name, or by
selecting from the [BSI RTUs] button in ControlView while
NetView or LocalView are running. You should NOT attempt to
edit the Hosts file yourself.
Click Connect and the utility displays a list of files available for
uploading from the ControlWave. (If there is only one file in the
Note: If file being uploaded is a zipped (compressed file), the file will
automatically be uncompressed, and the application launched
will depend on entries made in the STARTUP.INI file.
Headquarters:
Emerson Process Management
Remote Automation Solutions
6005 Rogerdale Road
Houston, TX 77072 U.S.A.
T +1 281 879 2699 | F +1 281 988 4445
www.EmersonProcess.com/Remote
Europe:
Emerson Process Management © 2014 Remote Automation Solutions, a business unit of Emerson Process Management.
Remote Automation Solutions All rights reserved.
Emerson House
Unit 8, Waterfront Business Park Remote Automation Solutions, a business unit of Emerson Process Management, shall not
Dudley Road, Brierly Hill be liable for technical or editorial errors in this manual or omissions from this manual.
Dudley UK DY5 1LX REMOTE AUTOMATION SOLUTIONS MAKES NO WARRANTIES, EXPRESSED OR
T +44 1384 487200 | F +44 1384 487258 IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
www.EmersonProcess.com/Remote FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THIS MANUAL AND, IN
North American/Latin America: NO EVENT SHALL REMOTE AUTOMATION SOLUTIONS BE LIABLE FOR ANY
INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING, BUT
Emerson Process Management
NOT LIMITED TO, LOSS OF PRODUCTION, LOSS OF PROFITS, LOSS OF REVENUE
Remote Automation Solutions
6005 Rogerdale Road OR USE AND COSTS INCURRED INCLUDING WITHOUT LIMITATION FOR CAPITAL,
FUEL AND POWER, AND CLAIMS OF THIRD PARTIES.
Houston TX USA 77072
T +1 281 879 2699 | F +1 281 988 4445 Emerson Process Management Ltd, Remote Automation Solutions (UK), is a wholly owned
www.EmersonProcess.com/Remote subsidiary of Emerson Electric Co. doing business as Remote Automation Solutions, a
Middle East/Africa: business unit of Emerson Process Management. FloBoss, ROCLINK, ControlWave,
Emerson Process Management Helicoid, and OpenEnterprise are trademarks of Remote Automation Solutions. AMS,
Remote Automation Solutions PlantWeb, and the PlantWeb logo are marks owned by one of the companies in the
Emerson FZE Emerson Process Management business unit of Emerson Electric Co. Emerson Process
P.O. Box 17033 Management, Emerson and the Emerson logo are trademarks and service marks of the
Jebel Ali Free Zone – South 2 Emerson Electric Co. All other marks are property of their respective owners.
Dubai U.A.E.
The contents of this publication are presented for informational purposes only. While every
T +971 4 8118100 | F +971 4 8865465 effort has been made to ensure informational accuracy, they are not to be construed as
www.EmersonProcess.com/Remote
warranties or guarantees, express or implied, regarding the products or services described
Asia-Pacific: herein or their use or applicability. Remote Automation Solutions reserves the right to modify
Emerson Process Management or improve the designs or specifications of such products at any time without notice. All
Remote Automation Solutions sales are governed by Remote Automation Solutions’ terms and conditions which are
1 Pandan Crescent available upon request. Remote Automation Solutions does not assume responsibility for
Singapore 128461 the selection, use or maintenance of any product. Responsibility for proper selection, use
T +65 6777 8211| F +65 6777 0947 and maintenance of any Remote Automation Solutions product remains solely with the
www.EmersonProcess.com/Remote purchaser and end-user.