Professional Documents
Culture Documents
U40A-001
LIQUID PENETRANT Date : 22/09/2016
EXAMINATION REPORT Page : 1 of 2
CLIENT : BINH SON REFINING AND PETROCHEMICAL CO. LTD CODE/ STANDARD : ASME I (2015 Ed.)
PROJECT : DUNG QUAT REFINERY ACCEPTANCE CRITERIA : ASME I, A-270 (2015 Ed.)
LOCATION : BINH SON, QUANG NGAI, VIET NAM NDT EXTENT : AS SHOW IN ATTACHED PICTURE(S)
ITEM : A-4002A PROCEDURE : PTC.BSR.PT01 REV.01
MATERIAL : CARBON STEEL PRODUCT TYPE : WELDING
SKETCH : SEE ATTACHED PICTURE(S) PROCESS : N/A
Prepared edge After Welding After PWHT
State of Examination
Base Metal After Repair In-service
Type of joint Butt joint Tee-joint Corner-joint Lap-joint
Surface Condition Flush Grinding As weld
Surface Cleaning Sligtly grinding Brushing Using cleaner Other
0
Surface Temperature Ambient < 57 C
Lighting Condition Day light > 1000 lux Artificial > 1000 lux Black Light
Lighting Meter : N/A Serial : N/A Next Cal. Due : N/A
Penetrant apply method Spraying Dipping Brushing
PT MATERIAL MANUFACTURE BRAND NAME BATCH NO. TYPE DWELL TIME
Penetrant NABAKEM MEGA CHECK - MCP-2010 Colour contrast 5 min
Remover NABAKEM MEGA CHECK - MCC-1010 Solvent 1 min
Developer NABAKEM MEGA CHECK - MCD-3010 Wet Solvent base 10 ~ 15 min
EXAMINATION RESULTS
THICK WELDED INSP. INDICATION EVALUATION
INSPECTED
WELD I.D -NESS LENGTH LENGTH REMARKS
SIZE LOCATION DATE
(mm) (mm) (mm) NO. TYPE ACC REJ
(mm) (mm)
206 50 50 22-Sep-16
207 50 50 22-Sep-16
208 50 50 22-Sep-16
209 50 50 22-Sep-16
210 50 50 22-Sep-16
211 50 50 22-Sep-16
212 50 50 22-Sep-16
213 50 50 22-Sep-16
214 50 50 22-Sep-16
215 50 50 22-Sep-16
216 50 50 22-Sep-16
217 50 50 22-Sep-16
REJ: Rejected P: Pore/ Porosity OV: Overlap LOP: Lack of penetration R: Rounded indication
PHATECO APPROVED BY BSR
Prepared by Reviewed by
Remarks: The red indications in the images above are non-relevant indications due to the gaps closeness