You are on page 1of 1

Travelling Block Assembly

ALMANSOORI INSPECTION SERVICES


MAGNETIC PARTICLE INSPECTION REPORT

CUSTOMER Adavnced Energy System REPORT NO. 5010051895-MPI-002 DATE 02-Mar-2022 PAGE 1 OF 1

LOCATION ADES-40 WORK ORDER NO./PURCHASE ORDER NO 5010051895

INSPECTION CATEGORY ACCEPTANCE OEM/CLIENT PROC. No.


INSPECTION STANDARD ASTM E 709 MIS Proc. No. 7 Rev.05 N/A
STANDARD ( If applicable)
Cat.lll Cat.lV Client NA X
TYPE OF INSPECTION Wet Visible Magnetic Particles Inspection
ITEM
DESCRIPTION Elevator Link Ears IDENTIFICATION No. 189504, 189505

Critical Area X Full Body Welded


INSPECTION RESULT

No relevant indication has been found at the time of inspection

COMMENTS:

Photo of item section with ID No. N/A MPI has been carried out on highlighted areas as per client request

INSPECTED AREA HIGHLIGHTED AS;

EQUIPMENT & TECHNICAL DETAILS PERSONNEL DETAILS


WHITE CONTRAST PAINT MAGNETIC PARTICLE
EQUIPMENT AC YOKE
BRAND BATCH NO. BRAND BATCH NO.
INSPECTOR NAME: MOHAMED YASIR CUSTOMER REP.NAME:

MODEL Ferrous Probe MR72 72/2103 MR76S 768/3102 QUALIFICATION: NDT LEVEL II SIGN:

SURFACE COND: ( Must be bare


S.NO. ACY-050
metal)
Bare metal DATE:

MAGNETIC FIELD INDICATOR Castrol Strip SIGNATURE & STAMP


STAMP
INSPECTION TECHNIQUE Longitudinal Magnetization
Abbreviations: S.No= Serial Number, , MAG.PARTICLE= Magnetic Particle, W.CONTRAST= White Contrast, COND= Condition,NA= Not Available, CAT= Category

OEM= Original Equipment Manufacturer , PROC=Procedure, No= Number

F.588 (MIS)
www.almansoori.biz| E- Mail: mis@almansoori.biz Rev.03
15.09.2016