CUSTOMER Advance Energy Systems REPORT NO. 5010050776-SC-001 DATE 22-Feb-2022 PAGE 1
MEASURED ACCEPT.LIMIT
PART / SECTION RESULT/ COMMENT
VALUE MIN/MAX
HINGE PIN CLEARANCE (A) 0.04" 0,05” Max Accepted
CLEARANCE BETWEEN INSERT
No Gap 0,07” Max Accepted
AND SLOT (B)
HINGE BORE DIA (C) 1.1" 1,3” Max Accepted
Manufacturer : FORUM Size & Model: Type MP Capacity: N/A INSPECTION RESULT/ COMMENTS
NB: Reported values are maximum of measured values.
Photo of item section with ID No.
Cat 4 inspection has been carried out as per API RP 7L & OEM
INSPECTED AREA HIGHLIGHTED AS; Full Body NO RELEVANT INDICATION FOUND AT THE TIME OF INSPECTION
EQUIPMENT & TECHNICAL DETAILS PERSONNEL DETAILS
WHITE MAG.PARTICLE INSPECTOR
MOHAMED YASIR
EQUIPMENT AC YOKE CONT.MODEL MR72 MODEL # MR76S NAME: CUSTOMER NAME:
W.CONTRAST MAG.PARTICLE
QUALIFICATION: NDT LEVEL II
MODEL Ferrous Probe BATCH # 72/2103 BATCH # 768/3102 SIGN:
F.1461
Rev.0
05.06.2017
ALMANSOORI INSPECTION SERVICES
RIG EQUIPMENT INSPECTION CHECKLIST
EQUIPMENT NAME Safety Clamp
COMPLIANCE TO THE
SR# INSPECTION CHECK POINTS STANDARDS/PROCEDURE VALUES / DESCRIPTION
YES NO N/A OBS
Documentation Review
1 Have you verified the Records of previous CAT III and CAT IV inspection? YES
2 Have you checked for significant defects recorded in the drawing or the previous inspection? YES
3 Have you checked for any actions recommended in the previous report? YES
4 Have you checked the location and extent of the repairs given in the previous report? YES
5 Have you checked for NDT inspection performed and the results of the inspection? YES
6 Have you checked for the records if there is any Primary load-carrying components replaced or manufactured? YES
1 Have you identified the Identification number and OEM Identification on the equipment? YES
2 Have you identified the Size, Capacity & Model using COC or marking on the Equipment? YES
3 Have you identified the category of inspection to be carried out based on previous inspection? YES
4 Have you checked the Adequate dismantling to access all critical areas for CAT III as per OEM Manual? YES
5 Have you checked the Adequate dismantling to access all critical areas for CAT IV as per OEM Manual? YES
6 Have you checked for any Visual Cracks, loose fits or connections & elongation? YES
7 Have you checked for any Signs of wear, corrosion, over loading & evidence of unauthorized field welding? YES
8 Have you checked for any Potential dropped objects or damaged missing retention devices? YES
9 Have you checked for the Missing components, deterioration & Lubrication? YES
1 Have you verified the surface to confirm adequate paint and foreign material removal? YES
2 Have you taken the photo as evidence of proper surface preparation? YES
Dimensional inspection
10
11
1 Did you notify the customer when the equipment rejected? N/A
2 Have you received the client acknowledgement particularly for the rejected equipment? N/A
COMMENTS :
Mohamed Yasir
F.1620
Rev.0
AlMansoori Inspection Services ,P.O.Box: 3599 ,Al Khobar 31952 ,KSA, Email:mis@almansoori.biz, Web: www.almansoori.biz
28.05.2020
ALMANSOORI INSPECTION SERVICES
RIG EQUIPMENT INSPECTION REPORT
CUSTOMER Advance Energy Systems REPORT NO. 5010050776-SC-002 DATE 22-Feb-2022 PAGE 1
MEASURED ACCEPT.LIMIT
PART / SECTION RESULT/ COMMENT
VALUE MIN/MAX
HINGE PIN CLEARANCE (A) 0.041" 0,05” Max Accepted
CLEARANCE BETWEEN INSERT
No Gap 0,07” Max Accepted
AND SLOT (B)
HINGE BORE DIA (C) 1.15" 1,3” Max Accepted
Manufacturer : FORUM Size & Model: Type MP Capacity: N/A INSPECTION RESULT/ COMMENTS
NB: Reported values are maximum of measured values.
Photo of item section with ID No.
Cat 4 inspection has been carried out as per API RP 7L & OEM
INSPECTED AREA HIGHLIGHTED AS; Full Body NO RELEVANT INDICATION FOUND AT THE TIME OF INSPECTION
EQUIPMENT & TECHNICAL DETAILS PERSONNEL DETAILS
WHITE MAG.PARTICLE INSPECTOR
MOHAMED YASIR
EQUIPMENT AC YOKE CONT.MODEL MR72 MODEL # MR76S NAME: CUSTOMER NAME:
W.CONTRAST MAG.PARTICLE
QUALIFICATION: NDT LEVEL II
MODEL Ferrous Probe BATCH # 72/2103 BATCH # 768/3102 SIGN:
F.1461
Rev.0
05.06.2017
ALMANSOORI INSPECTION SERVICES
RIG EQUIPMENT INSPECTION CHECKLIST
EQUIPMENT NAME Safety Clamp
COMPLIANCE TO THE
SR# INSPECTION CHECK POINTS STANDARDS/PROCEDURE VALUES / DESCRIPTION
YES NO N/A OBS
Documentation Review
1 Have you verified the Records of previous CAT III and CAT IV inspection? YES
2 Have you checked for significant defects recorded in the drawing or the previous inspection? YES
3 Have you checked for any actions recommended in the previous report? YES
4 Have you checked the location and extent of the repairs given in the previous report? YES
5 Have you checked for NDT inspection performed and the results of the inspection? YES
6 Have you checked for the records if there is any Primary load-carrying components replaced or manufactured? YES
1 Have you identified the Identification number and OEM Identification on the equipment? YES
2 Have you identified the Size, Capacity & Model using COC or marking on the Equipment? YES
3 Have you identified the category of inspection to be carried out based on previous inspection? YES
4 Have you checked the Adequate dismantling to access all critical areas for CAT III as per OEM Manual? YES
5 Have you checked the Adequate dismantling to access all critical areas for CAT IV as per OEM Manual? YES
6 Have you checked for any Visual Cracks, loose fits or connections & elongation? YES
7 Have you checked for any Signs of wear, corrosion, over loading & evidence of unauthorized field welding? YES
8 Have you checked for any Potential dropped objects or damaged missing retention devices? YES
9 Have you checked for the Missing components, deterioration & Lubrication? YES
1 Have you verified the surface to confirm adequate paint and foreign material removal? YES
2 Have you taken the photo as evidence of proper surface preparation? YES
Dimensional inspection
10
11
1 Did you notify the customer when the equipment rejected? N/A
2 Have you received the client acknowledgement particularly for the rejected equipment? N/A
COMMENTS :
Mohamed Yasir
F.1620
Rev.0
AlMansoori Inspection Services ,P.O.Box: 3599 ,Al Khobar 31952 ,KSA, Email:mis@almansoori.biz, Web: www.almansoori.biz
28.05.2020
ALMANSOORI INSPECTION SERVICES
RIG EQUIPMENT INSPECTION REPORT
CUSTOMER Advance Energy Systems REPORT NO. 5010050776-SC-003 DATE 22-Feb-2022 PAGE 1
MEASURED ACCEPT.LIMIT
PART / SECTION RESULT/ COMMENT
VALUE MIN/MAX
HINGE PIN CLEARANCE (A) 0.039" 0,05” Max Accepted
CLEARANCE BETWEEN INSERT
No Gap 0,07” Max Accepted
AND SLOT (B)
HINGE BORE DIA (C) 1.10" 1,3” Max Accepted
Manufacturer : FORUM Size & Model: Type MP Capacity: N/A INSPECTION RESULT/ COMMENTS
NB: Reported values are maximum of measured values.
Photo of item section with ID No.
Cat 4 inspection has been carried out as per API RP 7L & OEM
INSPECTED AREA HIGHLIGHTED AS; Full Body NO RELEVANT INDICATION FOUND AT THE TIME OF INSPECTION
EQUIPMENT & TECHNICAL DETAILS PERSONNEL DETAILS
WHITE MAG.PARTICLE INSPECTOR
MOHAMED YASIR
EQUIPMENT AC YOKE CONT.MODEL MR72 MODEL # MR76S NAME: CUSTOMER NAME:
W.CONTRAST MAG.PARTICLE
QUALIFICATION: NDT LEVEL II
MODEL Ferrous Probe BATCH # 72/2103 BATCH # 768/3102 SIGN:
F.1461
Rev.0
05.06.2017
ALMANSOORI INSPECTION SERVICES
RIG EQUIPMENT INSPECTION CHECKLIST
EQUIPMENT NAME Safety Clamp
COMPLIANCE TO THE
SR# INSPECTION CHECK POINTS STANDARDS/PROCEDURE VALUES / DESCRIPTION
YES NO N/A OBS
Documentation Review
1 Have you verified the Records of previous CAT III and CAT IV inspection? YES
2 Have you checked for significant defects recorded in the drawing or the previous inspection? YES
3 Have you checked for any actions recommended in the previous report? YES
4 Have you checked the location and extent of the repairs given in the previous report? YES
5 Have you checked for NDT inspection performed and the results of the inspection? YES
6 Have you checked for the records if there is any Primary load-carrying components replaced or manufactured? YES
1 Have you identified the Identification number and OEM Identification on the equipment? YES
2 Have you identified the Size, Capacity & Model using COC or marking on the Equipment? YES
3 Have you identified the category of inspection to be carried out based on previous inspection? YES
4 Have you checked the Adequate dismantling to access all critical areas for CAT III as per OEM Manual? YES
5 Have you checked the Adequate dismantling to access all critical areas for CAT IV as per OEM Manual? YES
6 Have you checked for any Visual Cracks, loose fits or connections & elongation? YES
7 Have you checked for any Signs of wear, corrosion, over loading & evidence of unauthorized field welding? YES
8 Have you checked for any Potential dropped objects or damaged missing retention devices? YES
9 Have you checked for the Missing components, deterioration & Lubrication? YES
1 Have you verified the surface to confirm adequate paint and foreign material removal? YES
2 Have you taken the photo as evidence of proper surface preparation? YES
Dimensional inspection
10
11
1 Did you notify the customer when the equipment rejected? N/A
2 Have you received the client acknowledgement particularly for the rejected equipment? N/A
COMMENTS :
Mohamed Yasir
F.1620
Rev.0
AlMansoori Inspection Services ,P.O.Box: 3599 ,Al Khobar 31952 ,KSA, Email:mis@almansoori.biz, Web: www.almansoori.biz
28.05.2020