You are on page 1of 4

TECHNICO INDUSTRIES LIMITD, CHENNAI

CUSTOMER NAME :-RENAULT NISSAN INSPECTION INSTRUCTION SHEET DOC NO:TIL/FW/IIS/RBC/BD


PART NO. 844006559R FORMAT NO.
INSPECTION TOOL
PART NAME RBC- BACK DOOR HINGE F/QA/16 PROCESS NO:1000

SL.NO. INSPECTION ITEM CHECK POINT CHECKING METHOD IMPORTANCE OF CHECK POINTS INSPECTION TOOL PART
FIG. -A

0.0 PART IDENTIFICATION TAG PART IDENTIFICATION TAG AVAILABILITY MANUAL CHECK AVOID ANY WRONG PART

1.0 RENAULT & 77R LOGO


RENAULT & 77R LOGO MARK
VISUAL CHECK PART REJECTED
1.0
MISS

BATCH CODE MISS/ DOUBLE BATCH CODE


1.1 CHECK BATCH CODE VISUAL CHECK TRACEABILITY MISMATCH
/WRONG BATCH CODE
FIG. -B

1.2 CHECK HOLE SHIFT MALE PART CD HOLE SHIFT VISUAL CHECK PART REJECTED

DENT ,LINE MARK ,,TRIM LINE BURR, EDGE


1.3 APPEARANCE BURR ,PLATING NG (BLACK MARK, WATER VISUAL CHECK PART REJECTED 1.3
MARKS ,RUSTetc..,)

2.0 RIVET CRACK NO RIVET CRACK/DAMAGE VISUAL CHECK FUNCTIONAL /STRENGTH LESS
FIG-C

2.1 RIVET HEAD RIVET HEAD CRACK//DAMAGE VISUAL CHECK FUNCTIONAL /STRENGTH LESS
2.0

CHECK BUSH AVAILABILITY STEEL & NYLON BUSH / NO BUSH POSSIBLE FOR FITMENT DOOR MOVEMENT
3.0 VISUAL CHECK
(STEEL BUSSH 1NO., NYLON BUSH 1NO ) DAMAGE/BUSH MISS ISSUE AT CAR BODY
FIG.-D

DENT ,LINE MARK ,,TRIM LINE BURR, EDGE


3.1 APPEARANCE BURR ,PLATING NG (BLACK MARK, WATER VISUAL CHECK PART REJECTED
MARKS,RUST etc..,)

4.0 SEALER ( BLACK ) SEALER MISS / DAMAGE/WRONG SEALER VISUAL CHECK WATER LEAKAGE ISSUE

NUT NOT FITTED ON THE BOLT WHEN HINGE


4.1 THREAD THREAD DAMAGE VISUAL CHECK
ASSY
4.1
FIG.-E

4.2 OPERATING EFFORT -MOVEMENT JERK / HARD/ LOOSE MOVEMENT MANUAL CHECK PART REJECTED

DENT ,LINE MARK ,,TRIM LINE BURR, EDGE


4.3 APPEARANCE BURR ,PLATING NG (BLACK MARK, WATER VISUAL CHECK PART REJECTED
4.2
MARKS etc..,)

F/QA/16 - 2
OK PARTS BIN IDENTIFICATION WITH
5.0 OK PARTS IDENTIFICATION VISUAL CHECK 5.0
INSPECTER ID
FIG. -F

TRACEABILITY
PART IDENTIFICATION TAG AVAILABILITY
5.1 PART IDENTIFICATION TAG VISUAL CHECK
WITH INSPECTOR SIGNATURE

REV.NO. RIVISION CONTENTS DATE PREPARED BY. CHECKED BY


0 NEW FORMAT UPDATE 03.07.2018 VENKAT MANIVEL

F/QA/16 - 2
NDUSTRIES LIMITD, CHENNAI

DOC NO:TIL/FW/IIS/RBC/BDH-00

SAFETY

PART VIEWS

FIG.A

FIG.B 1.1

1.2

FIG.-C

2.1
FIG.-D

3.0

3.1

FIG.E
4.0

4.3

F/QA/16 - 2
FIG.F
FIG.F

5.1

APPROVED BY
PRABHAKARAN .K

F/QA/16 - 2

You might also like