Professional Documents
Culture Documents
Series SY100
Specifications
Fluid Air
Ambient and fluid temperature (°C) –10 to 50°C (No freezing. Refer to page 4-18-4.)
Response time (ms) (1) 10 or less
Max. operating frequency (Hz) 20
Non-locking push type, Locking slotted type
Manual override Push-turn locking slotted type
Push-turn locking lever type {SY112 4, SY1124A only}
Lubrication Not required
Mounting position Unrestricted
Body ported Impact/Vibration resistance (m/s2) (2) 150/30
Enclosure Dustproof
Note 1) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature: 20°C, at rated
voltage, without surge suppressor.)
Note 2) Impact resistance: No malfunction occurred when it is tested with a drop tester in the axial
direction and at the right angles to the main valve and armature in both
energized and de-energized states every once for each condition. (Values at
the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test
was performed at both energized and de-energized states in the axial direction
and at the right angles to the main valve and armature. (Values at the initial
period)
Base mounted
Solenoid Specifications
Series SY1 13
24 SY113
24 A
Model
(2)
Operating
Function
3
N.C. SY11 4 Standard 0 to 0.7 –100 kPA to 0.6 –100 kPA to 0 M3 x 0.5 M3 x 0.5 0.14
3
N.C. SY11 4 A Large flow 0 to 0.7 –100 kPA to 0.6 –100 kPA to 0 M3 x 0.5 M3 x 0.5 0.22
SY13(A): 13 SY13(A): 15
(1) SY14(A): 24 SY14(A): 26
3 –100 kPA to 0 –100 kPA to 0.6 M3 x 0.5 M3 x 0.5 0.14
N.O. SY12 4 Standard 0 to 0.7 (12) (14)
(1)
N.O. SY12 34 A Large flow 0 to 0.7 –100 kPA to 0 –100 kPA to 0.6 M3 x 0.5 M3 x 0.5 0.22
Note 1) SY123/SY12434 and SY123/SY12434A: Supply pressure to 1(R) port and exhaust air from 3(P) port.
Note 2) Value for DC. Add 1 g for AC. ( ): Without sub-plate.
4-3-4
Series SY100
How to Order
Standard type Light/Surge voltage suppressor
(Cv0.008) Nil Without light/surge voltage suppressor
S With surge voltage suppressor
Z With light/surge voltage suppressor
R With surge voltage suppressor (Non-polar type)
U With light/surge voltage suppressor (Non-polar type)
∗ For AC voltage valves there is no “S” option. It is
already built into the rectifier circuit.
∗ For “R” and “U”, DC voltage is only available.
V100
Porting specifications Bracket
Nil: For manifold P: For body ported type Nil: Without bracket
SY
to P, R, A port F: With bracket
3 port SYJ
Type of actuation VK
1 Normally closed
2 Normally open VZ
For manifold type 30, 31 “P” piping specifications only. VT
VP
Standard type
(Cv: 0.008) : Body ported SY1 1 3 5 L M3
VG
Standard type VP
(Cv: 0.008) : Base mounted SY1 1 4 5 M
S070
3 port
Rated voltage Port size VQ
For DC
Nil: Without sub-plate M3: With sub-plate
5 24 VDC VKF
6 12 VDC
V 6 VDC
S 5 VDC
VQZ
R 3 VDC
Sub-plate style
For AC (50/60 Hz)
VZ
For manifold type S41
1 100 VAC
2 200 VAC VS
(With gasket and screws)
3 110 VAC [115 VAC]
4 220 VAC [230 VAC] VFN
L
P
H: 600 mm LN: Without LO: Without MO: Without B: Locking slotted type E: Push-turn locking
lead wire lead wire connector connector lever type
21 L
463 P
4-3-5
Series SY100
How to Order
Large flow type Light/Surge voltage suppressor
(Cv: 0.012) Nil Without light/surge voltage suppressor
S With surge voltage suppressor
Z With light/surge voltage suppressor
R With surge voltage suppressor (Non-polar type)
U With light/surge voltage suppressor (Non-polar type)
3 port
Type of actuation
1 Normally closed
2 Normally open
“P” piping specifications only.
For manifold type 30, 31
Sub-plate type
For manifold type S41 Large flow type
L
P
H: 600 mm LN: Without LO: Without MO: Without B: Locking slotted type E: Push-turn locking
lead wire lead wire connector connector lever type
21 L
463 P
4-3-6
Series SY100
Construction
SY114, SY114A
(A)
2
3
(R)
i q y e r w
V100
SY
SYJ
VK
VZ
VT
A R P
VP
!1 o u t !0
VG
VP
S070
VQ
VKF
Component Parts Replacement Parts
No. Description Material Note No. Description Part no. Material VQZ
q Body Resin Gray !0 Sub-plate SY100-74-1 Zinc die-casted
w Cover Resin Gray !1 Gasket VJ100-6-8 HNBR VZ
e Push rod Resin —
r Movable iron core assembly HNBR/Stainless steel —
t Fixed iron core Stainless steel —
VS
y Exhaust poppet HNBR —
u Return spring Stainless steel — VFN
i Poppet spring Stainless steel —
o Coil assembly — —
4-3-7
Series SY100
Body Ported
G
Grommet (G), (H): SY112 3 (A)- H -PM3(-F)
21.3
4 9
1.7
6.6
21
16
10
2-ø1.8 2-ø2.8
(Mounting hole) (Mounting hole)
(Light/Surge voltage suppressor)
23.8
(For AC) Manual override
28 (For DC)
– +
P G: ≅ 300
15.6
H: ≅ 600
11.5
12
6
9
(Lead wire length)
R A
2.8
3
1.5
1
19.5
1
L plug connector (L): SY1 2 3(A)-L-PM3(F) M plug connector (M): SY1 12 3(A)-M-PM3(-F)
+
–
23.7
(for AC)
≅ 300
A A
∗ Other dimensions are same as grommet type. ∗ Other dimensions are same as grommet type.
4-3-8
Series SY100
Base Mounted (With sub-plate)
Grommet (G), (H): SY1 12 4(A)- G
H -M3
15.6
Manual override 9
5
+ V100
13
15.5
–
P SY
13 3 2-ø2.6 SYJ
28 (Mounting hole)
(For DC) VK
34.5
(For AC) VZ
VT
G: ≅ 300
H: ≅ 600
(For DC)
G, H: 26.1
10 VP
VG
VP
(For AC)
S070
27.8
25.3
21.2
VQ
9
6
A R
VKF
5.5
3
4 9.5 5
19 VQZ
3-M3 x 0.5
(Piping port) VZ
1 1
VS
L plug connector (L): SY1 2 4(A)-L-M3 M plug connector (M): SY1 2 4(A)-M-M3
VFN
15.6 45.6
(Light/Surge voltage suppressor) (Light/Surge voltage suppressor) (For AC)
–
P P
(Lead wire length)
≅ 300 39.1
(Lead wire length) (For DC)
≅ 300
+ –
36
(For DC)
(For AC)
27.7
26.4
22.4
A A
∗ Other dimensions are same as grommet type. ∗ Other dimensions are same as grommet type.
4-3-9
Series SY
Made to Order Specifications:
Please contact SMC for detailed specifications, delivery and pricing.
Energy-saving Type
Power consumption is decreased by 1/3 by reducing the wattage required to hold the valve in an energized state. (Effective energizing
time is over 62 ms at 24 VDC.)
Specifications Working Principle
SY1 12 34 T SY1 12 34 AT
V100
Series The circuit shown below reduces current
consumption at holding which reduces the
Coil rated voltage (V) 24 DC, 12 DC
overall power consumption.
SY
Power consumption Inrush 0.55 0.8
Refer to electrical power waveform as
(W) Holding 0.22 0.3 shown below. SYJ
Specifications other than above are the same as standard models.
Electrical circuit (With energy-saving circuit) VK
How to Order Red
(+)
Diode
VZ
Coil
T
Timer circuit
LED
Body ported SY1 1 3 5 L Z M3
VT
1 2 Black
Base mounted SY1 1 4 T 5 M Z 1: Starting current, 2:
(–)
Holding current
VP
<Energy-saving Type, Electrical VG
Power Waveform for SY112 34 T>
Type of actuation
1 Normally closed Applied voltage
VP
2 Normally open 24 V
Entry is the same as S070
Body option standard products. 0V
Nil Standard VQ
A Large flow capacity Standard
0.55 W
Rated voltage
Energy-saving type VKF
0.22 W
5 24 VDC
6 12 VDC
0W
62 ms
VQZ
VZ
<Energy-saving Type, Electrical
Power Waveform for SY112 34AT> VS
Applied voltage
24 V VFN
0V
High flow type
0.8 W
Energy-saving type
0.3 W
0W
62 ms
SY1 X200
Entry is the same as standard products.
4-3-15