You are on page 1of 19

Proposed Residential house to be built

on Plot No.15, Block E-Bara in Lushoto-


Tanga

Architectural Drawing

Drawn by: Mr. Mac Drawn by: Mr. Mac


Phone: 0766-057-921 Phone: 0766-057-921
Email: Mr.macproductTz2022@gmail.com Email: Mr.macproductTz2022@gmail.com
GSPublisherVersion 0.12.100.100
3D VIEW

GSPublisherVersion 0.12.100.100
3D VIEW

GSPublisherVersion 0.12.100.100
Project Title:

Proposed Residential house to be


30,000
built on Plot No.15, Block E-Bara
in Lushoto-Tanga
GENERAL NOTE:
1.Designed as per BS standards
2.This drawing to be read in conjunction

19,500
with the architect's drawing

Garden Garden 3.Dimensions are in millimeters


4.Concrete grade 25(20) to be used having
minimum cube crushing strength of
17N/mm2 at 7 days and 28N/mm2 at 28
days
5.All dimensions to be chacked onsite and

40,000
on drawings, Any desrepancies to be
Car Parking
reported to the drawer/designer before
anywork put in hand

Verrandah
Entrance

Entrance
Master Entrance
Bedroom Verrandah Verrandah
6.Only figure dimension are to be taken
Toilet 7. Designing Steel and Concrete by Using
ct
Du Bedroom Si ng
room
2,000 BS5950 and BS 8110
Master
Bedroom DOWN

20

19
8.Concrete cover to main steel to be:
18

Study
(i) Foundations = 50, (ii) Columns = 30, (iii)
17

16
Dining
room 15

room
ct

Toilet
UP
14
Du

om
13

Beams = 25, (iv) Slabs = 25.


1

ro
12
2

19G x 300
20R x 150
11

h
ct

t
3

10

11,050 Ba
Du

Washing 5

6
9

Public room Kitchen


ct
Du

Toilet room

7
Store 19.10.2022
Kitchen
room Verrandah
2,000

Drawing Title: Physical address: Drawn and modified by: No: REVISION DESCRIPTION By Checked by: Date:
Site Plan Bara Area, Mr. Mac
P.o.box 32,
Lushoto-Tanga. Mobile Contact/WhatsApp: Drawing No: Date:
0766-057-921 RSA/MACC/001/01 19.10.2022
Email:
Client: Plot No: 15 Mr.macproductTz2022@gmail.com Revision No: Date:
Abdurahman Athuman
Block No: E-BARA Designed by:
Mr. Athuman J Mbwecha
Scale: 0683-412-740 Tunajali na kuthamini Don't Copy
1:35 hitaji la Mteja
GSPublisherVersion 0.11.100.100
Project Title:
A B C D E F G
16,950 Proposed Residential house to be
1,200 1,460
3,650 3,650 2,150 4,650 built on Plot No.15, Block E-Bara
1,420 1,420 610 610 440 1,200
2,200 2,200 1,500 1,650 2,200 1,500
in Lushoto-Tanga

A
1 1 GENERAL NOTE:
1.Designed as per BS standards

3,800

3,800
3,725

3,725
Ramp 2.This drawing to be read in conjunction
Car Parking
with the architect's drawing
C C
W1
2 2 3.Dimensions are in millimeters

475

2,000

2,000
Entrance
Master Entrance 4.Concrete grade 25(20) to be used having

2,500
Verrandah

2,200
Bedroom Verrandah

W1
W1
minimum cube crushing strength of

Verrandah
Entrance
W1 D1 14

935
3

305 900 550


500

3a D3 ED2 17N/mm2 at 7 days and 28N/mm2 at 28


1,200

Toilet
days

2,200
Bedroom

W1

4,700
4 D2 Si ng
1,300

room 5.All dimensions to be chacked onsite and


18,500

18,500
2,200

W1 D2 D2
5 on drawings, Any desrepancies to be

1,630
Master ED1
1,200

Bedroom ED2 ED2


6 D2 DOWN

6 reported to the drawer/designer before


1,450

1,745

20

anywork put in hand


19

2,200
18

Study

W1

3,000
Dining
17

7 D3 room 16

room 6.Only figure dimension are to be taken


1,200 1,300 1,200

900 900

15
W4

Toilet
UP
14

1,115
350

13

ED2
8 7. Designing Steel and Concrete by Using
1

12

om
2

D2 13

19G x 300
20R x 150
ro D3 D3 11
W4

th
10

a Washing
BS5950 and BS 8110
4

B 9

2,150
5

9 room 8
1,245

2,200
6
RG

Public Kitchen

W1
W4

Toilet D3 room 8.Concrete cover to main steel to be:


230

7
10 D2 10

1,050
W2 W2
(i) Foundations = 50, (ii) Columns = 30, (iii)
F

770
D2 D2 11
2,700

2,700

W3 Beams = 25, (iv) Slabs = 25.

1,650
Store

1,650
room Kitchen
Verrandah
12 W2
12

19.10.2022
A

900 1,200 570 230


230 490 1,140 900 1,200
3,840 1,500 1,500 1,747 1,500

1,200 1,100 1,050


2,000 1,650 3,650 1,750 2,900 1,460

16,950

A A1 B C D D1 E E1 F G

Drawing Title: Physical address: Drawn and modified by: No: REVISION DESCRIPTION By Checked by: Date:
Ground Floor Plan Bara Area, Mr. Mac
P.o.box 32,
Lushoto-Tanga. Mobile Contact/WhatsApp: Drawing No: Date:
0766-057-921 RSA/MACC/001/02 19.10.2022
Email:
Client: Plot No: 15 Mr.macproductTz2022@gmail.com Revision No: Date:
Abdurahman Athuman
Block: E-BARA Designed by:
Mr. Athuman J Mbwecha
Scale: 0683-412-740 Tunajali na kuthamini Don't Copy
1:45 hitaji la Mteja
GSPublisherVersion 0.12.100.100
A B C D E F G Project Title:

1,200
16,950
Proposed Residential house to be
3,650 3,650 2,150 4,650 1,460
built on Plot No.15, Block E-Bara

A
610 610 440 1,200
1,420 2,200 1,420 2,200 1,500 1,650 2,200 1,550
in Lushoto-Tanga
1 1 GENERAL NOTE:
1.Designed as per BS standards

3,860

3,860
3,725

3,725
Verrandah
2.This drawing to be read in conjunction

C C with the architect's drawing


W1
2 2

475
3.Dimensions are in millimeters

2,000

2,000
Entrance Entrance
2,500
Verrandah 4.Concrete grade 25(20) to be used having

2,200
Verrandah

W1
W1
W1 D1 4 minimum cube crushing strength of

930
3 Master

Verrandah
Entrance
Bedroom D2 ED2 17N/mm2 at 7 days and 28N/mm2 at 28

2,200
2,750
3,000

D2
days

W1
Si ng
room
ED3 Bedroom
5.All dimensions to be chacked onsite and
5

7,700
1,630
1,200
20,160

20,160
Dressing ED1
W3

on drawings, Any desrepancies to be


1,200

Room
445

6 D2
reported to the drawer/designer before
1,450

ED2
1,000 900 900 900 900

W4

ED2

2,200
anywork put in hand

W1
D2
230 345 350 400

7 Master WC Dining
room
1,200 1,300 1,200

6.Only figure dimension are to be taken


W4

1,120
8 ED2
Bedroom
om
ro D3
D2 13 7. Designing Steel and Concrete by Using
W4

ath
B D2

2,150
9 BS5950 and BS 8110

2,200
Public Store
W4

Washing

W1
Toilet D3 room
10
room Kitchen 10 8.Concrete cover to main steel to be:

300 700
W2 room

420
D3 11 (i) Foundations = 50, (ii) Columns = 30, (iii)
2,700

Verrandah
W2 D3 11

Kitchen

2,000
Beams = 25, (iv) Slabs = 25.

1,700
1,700

RG

W3
12 W2
12
1,500

1,500
1,500

1,500
12 12
19.10.2022

230
3,840 1,500 1,500 1,580 2,150 1,500 1,650 1,500 1,500
A

1,200 530
450 1,200 1,270
2,000 1,850 2,150 3,150 1,500 1,460

16,950

A A1A2 B C C C D E E2 F G

Drawing Title: Physical address: Drawn and modified by: No: REVISION DESCRIPTION By Checked by: Date:
Upper Floor Plan Bara Area, Mr. Mac
P.o.box 32,
Lushoto-Tanga. Mobile Contact/WhatsApp: Drawing No: Date:
0766-057-921 RSA/MACC/001/03 19.10.2022
Email:
Client: Plot No: 15 Mr.macproductTz2022@gmail.com Revision No: Date:
Abdurahman Athuman
Block No: E-BARA Designed by:
Mr. Athuman J Mbwecha
Scale: 0683-412-740 Tunajali na kuthamini Don't Copy
1:45 hitaji la Mteja
GSPublisherVersion 0.12.100.100
Project Title:

Proposed Residential house to be


17,005
built on Plot No.15, Block E-Bara
6,550 1,945 3,885 4,625 in Lushoto-Tanga
GENERAL NOTE:
1.Designed as per BS standards

2,000
6,225
2.This drawing to be read in conjunction

400
with the architect's drawing
3.Dimensions are in millimeters

4,770
4.Concrete grade 25(20) to be used having
minimum cube crushing strength of
13,175

17N/mm2 at 7 days and 28N/mm2 at 28


1,385
4,840 days
15,875

15,875
5.All dimensions to be chacked onsite and

13,875
on drawings, Any desrepancies to be
5,200

reported to the drawer/designer before


anywork put in hand
6.Only figure dimension are to be taken
3,585
800

7. Designing Steel and Concrete by Using


275

800 BS5950 and BS 8110


2,425

8.Concrete cover to main steel to be:


(i) Foundations = 50, (ii) Columns = 30, (iii)
Beams = 25, (iv) Slabs = 25.

5,600 5,055 6,350

17,005
19.10.2022

Drawing Title: Physical address: Drawn and modified by: No: REVISION DESCRIPTION By Checked by: Date:
Roof Plan Bara Area, Mr. Mac
P.o.box 32,
Lushoto-Tanga. Mobile Contact/WhatsApp: Drawing No: Date:
0766-057-921 RSA/MACC/001/04 19.10.2022
Email:
Client: Plot No: 15 Mr.macproductTz2022@gmail.com Revision No: Date:
Abdurahman Athuman
Block No: E-BARA Designed by:
Mr. Athuman J Mbwecha
Scale: 0683-412-740 Tunajali na kuthamini Don't Copy
1:45 hitaji la Mteja
GSPublisherVersion 0.12.100.100
Project Title:

Proposed Residential house to be


built on Plot No.15, Block E-Bara
in Lushoto-Tanga
GENERAL NOTE:
17,005
1.Designed as per BS standards
1,153 780
775 170 780 775 1,179 366 780 2.This drawing to be read in conjunction
2,332 2,500 1,942 3,475
with the architect's drawing
3.Dimensions are in millimeters

950 963
4.Concrete grade 25(20) to be used having
minimum cube crushing strength of

1,500 1,500 1,500

1,475
17N/mm2 at 7 days and 28N/mm2 at 28
days

1,500 1,500 1,500 1,500 1,500 1,500


5.All dimensions to be chacked onsite and
on drawings, Any desrepancies to be
reported to the drawer/designer before
1,475
15,875

15,875
anywork put in hand
1,500 1,500 1,525

6.Only figure dimension are to be taken


7. Designing Steel and Concrete by Using
BS5950 and BS 8110
8.Concrete cover to main steel to be:
(i) Foundations = 50, (ii) Columns = 30, (iii)
773

778 1,124 1,475


1,128 1,475 Beams = 25, (iv) Slabs = 25.
1,500 1,500

19.10.2022
205 1,074
979 776
1,500 1,500 1,500

17,005

Drawing Title: Physical address: Drawn and modified by: No: REVISION DESCRIPTION By Checked by: Date:
Roof Layout Bara Area, Mr. Mac
P.o.box 32,
Lushoto-Tanga. Mobile Contact/WhatsApp: Drawing No: Date:
0766-057-921 RSA/MACC/001/05 19.10.2022
Email:
Client: Plot No: 15 Mr.macproductTz2022@gmail.com Revision No: Date:
Abdurahman Athuman
Block No: E-BARA Designed by:
Mr. Athuman J Mbwecha
Scale: 0683-412-740 Tunajali na kuthamini Don't Copy
1:45 hitaji la Mteja
GSPublisherVersion 0.12.100.100
Project Title:

Corrugated Iron Sheet Proposed Residential house to be


50X50mm Timber Purlin
150X50mm Timber Common Ra er built on Plot No.15, Block E-Bara
150X50mm Timber Strust
150X50mm King Post in Lushoto-Tanga
150X50mm Timber Tie Beam
GENERAL NOTE:
50X50mm Wall Plate
1.Designed as per BS standards
2.This drawing to be read in conjunction
with the architect's drawing
3.Dimensions are in millimeters
4.Concrete grade 25(20) to be used having
minimum cube crushing strength of
17N/mm2 at 7 days and 28N/mm2 at 28
days
5.All dimensions to be chacked onsite and

300

300
on drawings, Any desrepancies to be
reported to the drawer/designer before

3,000
2,700

2,700
anywork put in hand
350 650

1,000

1,000
6.Only figure dimension are to be taken

100 200 7. Designing Steel and Concrete by Using


BS5950 and BS 8110

1,850
3,000

8.Concrete cover to main steel to be:


2,700

(i) Foundations = 50, (ii) Columns = 30, (iii)

1,150
Beams = 25, (iv) Slabs = 25.
_+0 G.L _+0 G.L

19.10.2022

Tiles Floor Finish


230mm Founda on Wall 150mm Oversite Mass Concrete
200mm HardCore
230X690mm 230mm Founda on Wall
Founda on Foo ng 230X690mm Founda on Foo ng
Well Compated Soil

Drawing Title: Physical address: Drawn and modified by: No: REVISION DESCRIPTION By Checked by: Date:
Sec on A-A Bara Area, Mr. Mac
P.o.box 32,
Lushoto-Tanga. Mobile Contact/WhatsApp: Drawing No: Date:
0766-057-921 RSA/MACC/001/06 19.10.2022
Email:
Client: Plot No: 15 Mr.macproductTz2022@gmail.com Revision No: Date:
Abdurahman Athuman
Block No: E-BARA Designed by:
Mr. Athuman J Mbwecha
Scale: 0683-412-740 Tunajali na kuthamini Don't Copy
1:45 hitaji la Mteja
GSPublisherVersion 0.12.100.100
Project Title:

Proposed Residential house to be


built on Plot No.15, Block E-Bara
in Lushoto-Tanga
GENERAL NOTE:
1.Designed as per BS standards
2.This drawing to be read in conjunction
with the architect's drawing
35º
3.Dimensions are in millimeters
4.Concrete grade 25(20) to be used having
minimum cube crushing strength of
17N/mm2 at 7 days and 28N/mm2 at 28
days

3,300
5.All dimensions to be chacked onsite and
on drawings, Any desrepancies to be

650

200 200 100


1,000
reported to the drawer/designer before

350
anywork put in hand

500

300

5,400
6.Only figure dimension are to be taken
700

7. Designing Steel and Concrete by Using

1,600
100

2,000
3,300

3,300
BS5950 and BS 8110
3,000

3,000
8.Concrete cover to main steel to be:

100
1,900

(i) Foundations = 50, (ii) Columns = 30, (iii)


650
1,000

1,000

700
Beams = 25, (iv) Slabs = 25.
350

19.10.2022

Drawing Title: Physical address: Drawn and modified by: No: REVISION DESCRIPTION By Checked by: Date:
Sec on C-C Bara Area, Mr. Mac
P.o.box 32,
Lushoto-Tanga. Mobile Contact/WhatsApp: Drawing No: Date:
0766-057-921 RSA/MACC/001/07 19.10.2022
Email:
Client: Plot No: 15 Mr.macproductTz2022@gmail.com Revision No: Date:
Abdurahman Athuman
Block No: E-BARA Designed by:
Mr. Athuman J Mbwecha
Scale: 0683-412-740 Tunajali na kuthamini Don't Copy
1:20 hitaji la Mteja
GSPublisherVersion 0.12.100.100
Project Title:

Proposed Residential house to be


built on Plot No.15, Block E-Bara
in Lushoto-Tanga
GENERAL NOTE:
1.Designed as per BS standards
2.This drawing to be read in conjunction
with the architect's drawing
3.Dimensions are in millimeters
4.Concrete grade 25(20) to be used having
minimum cube crushing strength of
17N/mm2 at 7 days and 28N/mm2 at 28
Le Eleva on Front Eleva on
days
5.All dimensions to be chacked onsite and
on drawings, Any desrepancies to be
reported to the drawer/designer before
anywork put in hand
6.Only figure dimension are to be taken
7. Designing Steel and Concrete by Using
BS5950 and BS 8110
8.Concrete cover to main steel to be:
(i) Foundations = 50, (ii) Columns = 30, (iii)
Beams = 25, (iv) Slabs = 25.

19.10.2022

Back Eleva on Right Eleva on

Drawing Title: Physical address: Drawn and modified by: No: REVISION DESCRIPTION By Checked by: Date:
Eleva on Bara Area, Mr. Mac
P.o.box 32,
Lushoto-Tanga. Mobile Contact/WhatsApp: Drawing No: Date:
0766-057-921 RSA/MACC/001/08 19.10.2022
Email:
Client: Plot No: 15 Mr.macproductTz2022@gmail.com Revision No: Date:
Abdurahman Athuman
Block No: E-BARA Designed by:
Mr. Athuman J Mbwecha
Scale: 0683-412-740 Tunajali na kuthamini Don't Copy
1:45 hitaji la Mteja
GSPublisherVersion 0.12.100.100
Proposed Residential house to be built
on Plot No.15, Block E-Bara in Lushoto-
Tanga

Structural Drawing

Drawn by: Mr. Mac Drawn by: Mr. Mac


Phone: 0766-057-921 Phone: 0766-057-921
Email: Mr.macproductTz2022@gmail.com Email: Mr.macproductTz2022@gmail.com
GSPublisherVersion 0.12.100.100
Project Title:
A B C D E F G
Proposed Residential house to be
1,200 1,460
3,650 3,650 2,150 4,650 built on Plot No.15, Block E-Bara
in Lushoto-Tanga
F1 F1
GENERAL NOTE:
1 1
C1 C3 C3 C1
1.Designed as per BS standards
2.This drawing to be read in conjunction

3,725

3,725
with the architect's drawing

A4
F2 F2 F2 F2 F2
2 2 3.Dimensions are in millimeters
C2 C2 C4 C4 C4
4.Concrete grade 25(20) to be used having

A4

2,000
2,500 F2 F3a F2 minimum cube crushing strength of
F2

C2
14
C2 C2 C4 17N/mm2 at 7 days and 28N/mm2 at 28

F2
3 C2
500

3a C2
1,200

F2 F2 days

4,700
4 F2
C2 C2 F2 5.All dimensions to be chacked onsite and
1,300

C2 F2 C4 on drawings, Any desrepancies to be

C2

C2
5
1,200

F3a

F3a
F2 F2 C2
F3a reported to the drawer/designer before
6 6

C2

C2
C2 F2 C2
1,450

anywork put in hand

3,000
7 6.Only figure dimension are to be taken
1,200 1,300 1,200

F2 F3a F2

B
8 F2 F3b 7. Designing Steel and Concrete by Using
C2 C2 C4 C2 13
C2 C2

B
C2 BS5950 and BS 8110

2,150
9
F2 F2 F2 F2 F2 8.Concrete cover to main steel to be:
10 10
(i) Foundations = 50, (ii) Columns = 30, (iii)

1,050
C2 C2 C2 C2 C2 F2
11 Beams = 25, (iv) Slabs = 25.
2,700

C4

1,650
F2 F2 F2
12 12
C4 C2 C2
19.10.2022

1,200 1,100 1,050


2,000 1,650 3,650 1,750 2,900 1,460

A A1 B C D D1 E E1 F G

Drawing Title: Physical address: Drawn and modified by: No: REVISION DESCRIPTION By Checked by: Date:
Founda on Plan Bara Area, Mr. Mac
P.o.box 32,
Lushoto-Tanga. Mobile Contact/WhatsApp: Drawing No: Date:
0766-057-921 RSA/MACC/001/10 19.10.2022
Email:
Client: Plot No: 15 Mr.macproductTz2022@gmail.com Revision No: Date:
Abdurahman Athuman
Block No: E-BARA Designed by:
Mr. Athuman J Mbwecha
Scale: 0683-412-740 Tunajali na kuthamini Don't Copy
1:35 hitaji la Mteja
GSPublisherVersion 0.12.100.100
Project Title:
150mm block wall
375 Micron Dpm 100 mm Thick concrete slab Proposed Residential house to be
Standard DPM to BS 8102 (250 Micron Dpm built on Plot No.15, Block E-Bara
150 mm Thick compacted hardcore
1,200 in Lushoto-Tanga
Typical detail for wall thinckening 150mm block wall GENERAL NOTE:
for posi on of par on wall 375 Micron Dpm 100 mm Thick concrete slab 1.Designed as per BS standards
Standard DPM to BS 8102 (250 Micron Dpm 2.This drawing to be read in conjunction
_+ 0.000 GL 150 mm Thick compacted hardcore
300 with the architect's drawing
300X400mm Ground Beam GB
3.Dimensions are in millimeters
230mm Thick founda on blockwall

1,200

600
4.Concrete grade 25(20) to be used having
50mm C10 Blinding concrete
minimum cube crushing strength of
350 Pad foo ng
17N/mm2 at 7 days and 28N/mm2 at 28

600 600 days


1,200 5.All dimensions to be chacked onsite and
on drawings, Any desrepancies to be
SECTION B - B
reported to the drawer/designer before
anywork put in hand
150mm block wall 6.Only figure dimension are to be taken
375 Micron Dpm 100 mm Thick concrete slab 7. Designing Steel and Concrete by Using
Standard DPM to BS 8102 (250 Micron Dpm BS5950 and BS 8110
_+ 0.000 GL 300 150 mm Thick compacted hardcore
8.Concrete cover to main steel to be:
300X400mm Ground Beam GB
230mm Thick founda on blockwall (i) Foundations = 50, (ii) Columns = 30, (iii)
1,200

600

50mm C10 Blinding concrete Beams = 25, (iv) Slabs = 25.

350 Pad foo ng


18.10.2022
600 600
1,200

SECTION A- A

Drawing Title: Physical address: Drawn and modified by: No: REVISION DESCRIPTION By Checked by: Date:
Founda on Details Bara Area, Mr. Mac
P.o.box 32,
Lushoto-Tanga. Mobile Contact/WhatsApp: Drawing No: Date:
0766-057-921 RSA/MACC/001/11 18.10.2022
Email:
Client: Plot No: 15 Mr.macproductTz2022@gmail.com Revision No: Date:
Abdurahman Athuman
Block No: E-BARA Designed by:
Mr. Athuman J Mbwecha
Scale: 0683-412-740 Tunajali na kuthamini Don't Copy
1:20 hitaji la Mteja
GSPublisherVersion 0.14.100.100
Project Title:

Proposed Residential house to be


built on Plot No.15, Block E-Bara
STARTER BARS STARTER BARS in Lushoto-Tanga
_+0.000 GL GENERAL NOTE:
_+0.000 GL 1.Designed as per BS standards
300
300

1,200
600
02 01 2.This drawing to be read in conjunction

1,200
600
02 01
300 with the architect's drawing
300
600 600 3.Dimensions are in millimeters
600 600
1,200 4.Concrete grade 25(20) to be used having
50mm blinding 1,200 50mm blinding minimum cube crushing strength of
SECTION 2.7- 2.7 SECTION 2.6- 2.6 17N/mm2 at 7 days and 28N/mm2 at 28
days
5.All dimensions to be chacked onsite and

600
600
on drawings, Any desrepancies to be
reported to the drawer/designer before

24T16-01-200(12B+12T)
anywork put in hand
28T16-01-200(14B+14T)

6.Only figure dimension are to be taken


7. Designing Steel and Concrete by Using
2.6 2.6

1,200

2,400
2.7 2.7 1,460 BS5950 and BS 8110

2,160
8.Concrete cover to main steel to be:
(i) Foundations = 50, (ii) Columns = 30, (iii)
12T16-02-200(6T+6B)
12T16-02-200(6B+6T) Beams = 25, (iv) Slabs = 25.

18.10.2022

600
600

600 600 600 600

1,200 1,200

foo ng F3b (1200x1200x300mm) 1Nos foo ng F3a (1200x1200x300mm) 5Nos


Drawing Title: Physical address: Drawn and modified by: No: REVISION DESCRIPTION By Checked by: Date:
Founda on Details Bara Area, Mr. Mac
P.o.box 32,
Lushoto-Tanga. Mobile Contact/WhatsApp: Drawing No: Date:
0766-057-921 RSA/MACC/001/13 18.10.2022
Email:
Client: Plot No: 15 Mr.macproductTz2022@gmail.com Revision No: Date:
Abdurahman Athuman
Block No: E-BARA Designed by:
Mr. Athuman J Mbwecha
Scale: 0683-412-740 Tunajali na kuthamini Don't Copy
1:20 hitaji la Mteja
GSPublisherVersion 0.14.100.100
Project Title:

Proposed Residential house to be


built on Plot No.15, Block E-Bara
STARTER BARS
in Lushoto-Tanga
_+0.000 GL GENERAL NOTE:
300 STARTER BARS
1.Designed as per BS standards

1,200
600
02 01 GROUND FLOOR LEVEL
+000 2.This drawing to be read in conjunction
300 with the architect's drawing
600 600 02 01 3.Dimensions are in millimeters
1,200 50mm blinding 4.Concrete grade 25(20) to be used having
SECTION 2.8- 2.8 minimum cube crushing strength of
17N/mm2 at 7 days and 28N/mm2 at 28
days
6T16-02-200 B2 5.All dimensions to be chacked onsite and

600
on drawings, Any desrepancies to be

6T16-01-200 B1

600
reported to the drawer/designer before
20T16-01-200(10B+10T)

1,200
anywork put in hand
6.Only figure dimension are to be taken

600
7. Designing Steel and Concrete by Using
2.8 2.8

1,700
800
BS5950 and BS 8110
12T16-02-200(6B+6T) 8.Concrete cover to main steel to be:
(i) Foundations = 50, (ii) Columns = 30, (iii)
foo ng F2 (1200x1200x300mm) 28Nos
Beams = 25, (iv) Slabs = 25.
600

18.10.2022

600 600

1,200
foo ng F1 (1200x1200x300mm) 2Nos

Drawing Title: Physical address: Drawn and modified by: No: REVISION DESCRIPTION By Checked by: Date:
Founda on Details Bara Area, Mr. Mac
P.o.box 32,
Lushoto-Tanga. Mobile Contact/WhatsApp: Drawing No: Date:
0766-057-921 RSA/MACC/001/12 18.10.2022
Email:
Client: Plot No: 15 Mr.macproductTz2022@gmail.com Revision No: Date:
Abdurahman Athuman
Block No: E-BARA Designed by:
Mr. Athuman J Mbwecha
Scale: 0683-412-740 Tunajali na kuthamini Don't Copy
1:20 hitaji la Mteja
GSPublisherVersion 0.14.100.100
Project Title:

Proposed Residential house to be


built on Plot No.15, Block E-Bara
in Lushoto-Tanga
GENERAL NOTE:

PITCHED ROOF LEVEL 1.Designed as per BS standards


FIRST FLOOR LEVEL
3,000 2.This drawing to be read in conjunction
4T16-02 3,000 with the architect's drawing
300
300 3.Dimensions are in millimeters
17 T8 - 175 c/c

230
T8-02-175 4.Concrete grade 25(20) to be used having
EL

4T16-02

EL
17 T8 - 175 c/c
LEV

2.1 2.1

LEV
minimum cube crushing strength of

2,700
4T16-02 230 4T16-02

2,700
OR

17N/mm2 at 7 days and 28N/mm2 at 28

OR

230
T8-02-175
FLO

FLO
Sec on 2.1 - 2.1 2.4 2.4 days
230
ST

ND
5.All dimensions to be chacked onsite and
3,000
FIR

Sec on 2.4 - 2.4

OU
on drawings, Any desrepancies to be
300

GR
0.000 reported to the drawer/designer before
EL

anywork put in hand


17 T8 - 175 c/c

LEV

4T16-02 Column C1 (230 x 230mm) 2Nos 6.Only figure dimension are to be taken
4T16-02
2,700
OR

7. Designing Steel and Concrete by Using


FLO

2.2 2.2 BS5950 and BS 8110

230
T8-02-175
ND

8.Concrete cover to main steel to be:


OU

230 (i) Foundations = 50, (ii) Columns = 30, (iii)


GR

0.000
Beams = 25, (iv) Slabs = 25.
Sec on 2.2 - 2.2

Column C1 (230 x 230mm) 32Nos 18.10.2022

Drawing Title: Physical address: Drawn and modified by: No: REVISION DESCRIPTION By Checked by: Date:
Ground Floor Plan Bara Area, Mr. Mac
P.o.box 32,
Lushoto-Tanga. Mobile Contact/WhatsApp: Drawing No: Date:
0766-057-921 RSA/MACC/001/14 18.10.2022
Email:
Client: Plot No: 15 Mr.macproductTz2022@gmail.com Revision No: Date:
Abdurahman Athuman
Block No: E-BARA Designed by:
Mr. Athuman J Mbwecha
Scale: 0683-412-740 Tunajali na kuthamini Don't Copy
1:20 hitaji la Mteja
GSPublisherVersion 0.14.100.100
Project Title:

Proposed Residential house to be


built on Plot No.15, Block E-Bara
in Lushoto-Tanga
GENERAL NOTE:
1.Designed as per BS standards
2.This drawing to be read in conjunction
FIRST FLOOR LEVEL with the architect's drawing
3,000 4T16-02 3.Dimensions are in millimeters
FIRST FLOOR LEVEL 8T16-02
300 4.Concrete grade 25(20) to be used having
3,000 minimum cube crushing strength of

230
T8-02-175

EL
17 T8 - 175 c/c
300 T8-02-175 17N/mm2 at 7 days and 28N/mm2 at 28

LEV
600
4T16-02

2,700
230 days

OR
EL
17 T8 - 175 c/c

LEV

FLO
2.13 2.13 5.All dimensions to be chacked onsite and
Sec on 2.13 - 2.13
4T16-02
2,700

on drawings, Any desrepancies to be


OR

ND
300
FLO

OU
2.5 2.5 Sec on 2.5 - 2.5 reported to the drawer/designer before

GR
0.000 anywork put in hand
ND
OU

6.Only figure dimension are to be taken


GR

0.000 Column C4 (230 x 230mm) 8Nos 7. Designing Steel and Concrete by Using
BS5950 and BS 8110
Column C1 (300 x 600mm) 2Nos 8.Concrete cover to main steel to be:
(i) Foundations = 50, (ii) Columns = 30, (iii)
Beams = 25, (iv) Slabs = 25.

18.10.2022

Drawing Title: Physical address: Drawn and modified by: No: REVISION DESCRIPTION By Checked by: Date:
Column Details Bara Area, Mr. Mac
P.o.box 32,
Lushoto-Tanga. Mobile Contact/WhatsApp: Drawing No: Date:
0766-057-921 RSA/MACC/001/15 18.10.2022
Email:
Client: Plot No: 15 Mr.macproductTz2022@gmail.com Revision No: Date:
Abdurahman Athuman
Block No: E-BARA Designed by:
Mr. Athuman J Mbwecha
Scale: 0683-412-740 Tunajali na kuthamini Don't Copy
1:20 hitaji la Mteja
GSPublisherVersion 0.14.100.100
Project Title:

6 T12 - 200 - 01 T1
Proposed Residential house to be

6 T12 - 200 - 01 T1
2T16 - 01 built on Plot No.15, Block E-Bara
A 2T16-01
T8-00 in Lushoto-Tanga
A
2T16-01 GENERAL NOTE:
13 T8-01-200 C/C 1.Designed as per BS standards

2T16 - 01 2.This drawing to be read in conjunction


with the architect's drawing
LANDING BEAM 230X200 C/C

2.10
3.Dimensions are in millimeters

2.9
4.Concrete grade 25(20) to be used having
minimum cube crushing strength of
6 T12 - 200 - 03 T1 6 T12 - 200 - 06 T1
17N/mm2 at 7 days and 28N/mm2 at 28

6 T12 - 200 - 02 T1 6 T12 - 200 - 07 T1 days


5.All dimensions to be chacked onsite and
on drawings, Any desrepancies to be
reported to the drawer/designer before
6 T12 - 200 - 01 T1 6 T12 - 200 - 08 T1
anywork put in hand
6.Only figure dimension are to be taken
2.10

2.9

7. Designing Steel and Concrete by Using


BS5950 and BS 8110
8.Concrete cover to main steel to be:
STAIRCASE PLAN RC DETAILS (i) Foundations = 50, (ii) Columns = 30, (iii)
Beams = 25, (iv) Slabs = 25.
FIRST FLOOR LEVEL 4T12-200 1,150
3,000
T12 18.10.2022
0
2-20 T12
T1 T12
T12 14
T12 LANDING LEVEL T12
_
+0.000 GL
T12 T12
T12 1,150 T12
T12
Section 2.10 - 2.10 T12 Section 2.9 - 2.9

Drawing Title: Physical address: Drawn and modified by: No: REVISION DESCRIPTION By Checked by: Date:
Staircase Details Bara Area, Mr. Mac
P.o.box 32,
Lushoto-Tanga. Mobile Contact/WhatsApp: Drawing No: Date:
0766-057-921 RSA/MACC/001/16 18.10.2022
Email:
Client: Plot No: 15 Mr.macproductTz2022@gmail.com Revision No: Date:
Abdurahman Athuman
Block No: E-BARA Designed by:
Mr. Athuman J Mbwecha
Scale: 0683-412-740 Tunajali na kuthamini Don't Copy
1:20 hitaji la Mteja
GSPublisherVersion 0.14.100.100

You might also like