You are on page 1of 47

Owners Manual

Model RMP 14-6


Congratulations on your purchase of the RigMaster® Power Auxiliary Power Unit.

The RigMaster® Power APU is a totally self contained, stand-alone AC generator, Air Conditioner
and Heater System. The only items that are shared with your truck systems are fuel and battery
supply. The RigMaster® Power APU also trickle charges the truck batteries while in operation.

Superior design and performance have been incorporated into this product to give you trouble-free,
economical operation. We are confident you will be satisfied with your new RigMaster Auxiliary
Power Unit.

The following pages contain design features, principles of operation, preventative maintenance
procedures and trouble shooting guides. Please review it carefully prior to starting and operating
your RigMaster® Power APU.

Should you have any questions or concerns please contact your nearest authorized RigMaster
Power Dealer, or RigMaster Power Corp. Product Support Group at:

1-888-208-3101
(For technical support only)
RigMaster Power Table of Contents
RMP14-6

TABLE OF CONTENTS

Principals Of Operation:
Heater (Pg 4)
Air Conditioner (Pg 6)
120 Volt Generator (Pg 7)

Pre-Start Inspection (Pg 8)

Control Panel Description and Operating Procedures (Pg 9)


Error Message Listing (Pg 16)

Fuel System Description and Bleeding Procedures (Pg17)

Preventative Maintenance Schedules (Pg 20)


Consumable Parts Cross Reference List (Pg 21)

Normal Maintenance And Adjustments Instructions:


Oil Change Instructions (Pg 22)
Generator Belt Removal/Adjustment (Pg 24)
Compressor Belt Removal/Adjustment (Pg 25)
Fan Belt Removal/Adjustments (Pg 26)
Breaker Reset Instructions (Pg 27)
Main Components and Part Locations (Pg 28)

Cleaning Instructions (Pg 29)

Trouble Shooting Guide (Pg 32)

Warranty:
RigMaster Limited Warranty (Pg 39)
12 Month Warranty Coverage (Pg 39)
24 Month or 4000 Hour Warranty Coverage (pg 39)
Warranty Obligations (Pg 39)
Disclaimer Of Other Warranties (Pg 39)
Maintenance (Pg 39)
Installation (Pg 40)
Warranty Voided Or Terminated (Pg 40)
Exclusions For Limited Warranty (Pg 40)
Limitation Of Remedies (Pg 40)
Indemnity (Pg 40)
Warranty Claims (Pg 40)
Transfer Of Warranty (Pg 41)
Warranty Policy (Pg 41)
Customer Assistance Procedure (Pg 42)

Maintenance Record (Pg 43)

Notes (Pg 46)

3
RigMaster Power Principals of Operations - Heater
RMP14-6

HEATER, AIR CONDITIONER, 120V GENERATOR

HEATER

RigMaster’s heating system is fully automatic. A constant comfort zone is maintained with the
temperature selector (see Climate Control Operation - Page 10). The bunk heating system has a
capacity of 13,500 BTU's. This is a complete stand alone system that is not integrated into the
vehicle's cooling system. When heat is selected, and the RigMaster® Power APU is in operation,
the hot coolant flows through the heater core (installed under the bunk see Figure 1).

The heater/air conditioner blower motor (fan) circulates the cab air through the heater core pushing
warm air into the bunk area. The coolant is then re-circulated back to the RigMaster’s main unit.

NOTE: PLUGGING IN THE BLOCK HEATER PLACES A LOAD OF APPROXIMATELY 1,500


WATTS ON THE ENGINE, THIS LOAD ENABLES THE ENGINE TO HEAT THE COOLANT.

This system is designed to maximize the bunk heating efficiency.

4
RigMaster Power Principals of Operations - Heater
RMP14-6

HEATER - FIGURE 1

Legend:
Hot Coolant Supply
Cold Coolant System
1) Engine
2) Radiator
3) Fill/Expansion Reservoir
4) Flow Control Valve
5) Heater/Air Conditioner Unit

5
RigMaster Power Principles of Operations – Air Conditioning
RMP14-6

AIR CONDITIONER

The RigMaster air conditioner is fully automatic. A constant comfort zone is maintained with the
temperature selector setting (see Climate Control Operation - Page 9). The RigMaster air
conditioner is a R134A system that is not integrated into the vehicle's existing air conditioning
system.

WARNING: ONLY CERTIFIED AIR CONDITIONING TECHNICIANS SHOULD SERVICE THE AIR CONDITIONER.

The compressor within the RigMaster main unit pumps the refrigerant gas through the condenser
that dissipates the heat and changes the refrigerant from a gas to a liquid. The liquid refrigerant
passes through a filter (receiver/dryer), and then through the evaporator core located in the bunk
heater/air conditioner unit. The heater/air conditioner blower motor (fan) then activates and cool,
dry air is then forced into the bunk area.

AIR CONDITIONER - FIGURE 2

Legend:

High Pressure Gas 1) Refrigerant Compressor


High Pressure Liquid 2) Condenser
Low Pressure Gas 3) Receiver Dryer
4) Heater / Air Conditioner Unit
5) Expansion Valve

6
RigMaster Power Principles of Operations- Generator
RMP14-6

120-VOLT GENERATOR

The 6kw heavy-duty generator is located at the rear of the RigMaster® Power APU and is belt
driven at 3600 RPM. The generator has two (2) factory supplied cords. One (1) block heater cord
(complete with a plug), allows the generator to be plugged into the vehicle's block heater. This
ensures that the vehicle's main engine will be warm when starting in cold weather. This provides a
load on the RigMaster engine that allows the APU to run more efficiently and prolong the
RigMaster's service life. The block heater connection uses one (1) – 20 AMP breaker. It is
recommended that the RigMaster remain plugged into the vehicle's block heater throughout
the winter months and unplugged for the spring and summer months. A second 20 AMP
supply of 120V power is supplied for the owner/operator convenience. A multiple outlet cord is
supplied and can be installed in the bunk area of the vehicle to provide power for 120V appliances.

GENERATOR - FIGURE 3

NOTE: Each 20 Amp Breaker has a capacity of 2400 Watts

Legend:
1) 6KW VAC Generator
2)-Connection Box comes with 2 -20AMP-Breakers: 1 for the Block Heater 1 for the Bunk Cord.

7
RigMaster Power Principles of Operations- Pre Start Inspection
RMP14-6

PRE-START INSPECTION

WITH THE RIGMASTER TURNED OFF

1) Remove the cover.

2) Visually inspect the unit for evidence of oil or coolant leakage.

3) Check the oil and add oil if necessary.

4) Check the tension and wear of all belts.

5) Check the mounting bolts and tighten if necessary.

6) Check for broken, corroded, or loose connectors and/or wires.

7) Check the physical condition and tightness of all hoses and hose clamps.

8) Replace and secure the cover.

8
RigMaster Power Principles of Operations – Control Panel
RMP14-6

CONTROL PANEL OPERATING PROCEDURES

6
3

4 CONTROL PANEL-FIGURE 4 5
1 The LCD MODULE DISPLAY is used to prompt the user through each operating mode.
The display will back light when the user touches any key and will turn off if not used for 30
seconds.

2 The GREEN STATUS light indicates the cabin controller is active and functional.
The RED STATUS light indicates a system problem and an error message will appear on
the display. (Refer to error message listing of this supplement).

NOTE: No STATUS light indicates the system is inactive (OFF).

3 The POWER key controls whether the module is active. Pushing the Power key will turn on
the LCD backlight and activate the menu display or will turn the system off.

4 The MODE key is used to activate the different operational modes and will back you out of
the menu mode to the main display.

5 The ARROW keys are used to locate the desired data and/or adjust those values.

6 The SELECT key enters the data and advances the program to the next menu step.

NOTE: Pressing the select button will save the information inputted when entering
operational data.

9
RigMaster Power Principles of Operations – Control Panel
RMP14-6

OPERATION OF THE CABIN CONTROLLER

Power On

When the RigMaster system is off, the cabin controller enters the low power mode and becomes
inactive, shutting off all non-critical functions. In low power mode the display shows: the day of the
week and date on the top line and the time and total hours of operation on the bottom line.
Pressing the POWER key will activate the normal mode turning the system on. The display will
light and the status LED will become green. The display will show the day of the week and time on
the top line and the system status (on/off) as well as the temperature setting on the bottom line.
Pressing the MODE key again will activate the menu mode. The display will show SELECT on the
top line and START SYSTEM on the bottom line.

Set Time/Date

NOTE: It is necessary to enter and date programming mode if the module has never been
programmed or a different time zone is required.

Press MODE key


Press UP or DOWN key to find Set Time / Date mode on the display
Press SELECT key
Press UP or DOWN key to find Set Time
Press SELECT key clock hour will start flashing
Press UP or DOWN key to adjust clock hour
Press SELECT key clock hour will stop flashing and clock minutes will start flashing
Press UP or DOWN key to adjust clock minutes
Press SELECT key clock minutes will stop flashing and am/pm will start flashing
Press UP or DOWN key to change am/pm
Press SELECT key to save settings and return to menu mode
Press MODE key to back out of the menu

To Set Date

Press MODE key


Press UP or DOWN key to find Set Time/Date mode on the display
Press SELECT key
Press UP or DOWN key to find Set Date mode
Press SELECT key Month will start flashing
Press UP or DOWN key to find the correct month
Press SELECT key Month will stop flashing and calendar date will start flashing
Press UP or DOWN key until correct date appears
Press SELECT key to save settings and return to menu mode
Press MODE key to back out of the menu

10
RigMaster Power Principles of Operations – Control Panel
RMP14-6

To Set Day

Press MODE key.


Press UP or DOWN key to find Set Time/Date mode on the display.
Press SELECT key
Press UP or DOWN key to find Set Day mode.
Press SELECT key
Press UP or DOWN key to find the correct day of the week.
Press SELECT key to save settings and return to menu.
Press MODE key to back out of the menu

Set Alarm Clock

Press MODE key


Press UP or DOWN key to find Set Alarm Clock mode.
Press SELECT key clock hour will start flashing
Press UP or DOWN key to adjust clock hour
Press SELECT key clock hour will stop flashing and clock minutes will start flashing
Press UP or DOWN key to adjust clock minutes
Press SELECT key clock minutes will stop flashing and am/pm will start flashing
Press UP or DOWN key to change am/pm
Press SELECT key on or off will display
Press UP or DOWN key to change setting
Press SELECT key to save changes and return to menu mode
Press MODE key to back out of the menu

Note: The Alarm symbol ‘*’will appear on the screen to indicate that the alarm is on.
When the alarm is activated the SELECT button will cancel the alarm and remove the alarm
symbol from the screen. If the alarm is not turned off manually it will ring for one minute and then
“snooze” for four minutes before sounding again.

Engine Start

Press MODE key


Start System will display
Press SELECT key
The control panel will display the status of the operation as it occurs:

• Starting System
• Glow Plugs and a 15 second countdown
• Cranking Engine
• Please Wait……
• Engine Running will display for 5 seconds and then return to the normal mode

The normal mode will display System On

11
RigMaster Power Principles of Operations – Control Panel
RMP14-6

Engine Stop

Press MODE key.


Stop System will display.
Press SELECT
The control panel will display the status of the operation as it occurs:

• Engine Running
• Engine Stopped

The control panel after 5 seconds will return to normal mode

Temperature Control

Press MODE key.


Press UP or DOWN key to find the Set Temperature mode
Press SELECT key
Press UP or DOWN keys to find desired temperature
Press SELECT key to save setting
Press MODE key to return to normal mode

NOTE: Temperature control ranges from 65ºF to 85ºF. The system will remember the last set
temperature when it is turned off

Fan Speed Control

Press MODE key.


Press UP or DOWN key to find the Set Fan Speed mode
Press SELECT key
Press UP or DOWN key to desired fan setting
Press SELECT key to save setting
Press MODE key to return to menu

NOTE: The system will remember the last fan setting after system is shutdown. To stop climate
control the fan speed MUST be set to the off setting. During warmer months use the
automatic on setting to improve air conditioner efficiency. During the cooler months use
the automatic off setting to improve heater efficiency.

Low Battery Alarm

When the truck battery voltage reaches 12.0 V +/- .2 Volts the low battery alarm will sound

12
RigMaster Power Principles of Operations – Control Panel
RMP14-6

AUTOSTART CONTROL OPTION

This feature can be purchased at an additional cost.

AutoStart Date/Time

Allows you to program the AutoStart to the exact date and time you need your RigMaster to start
automatically up to seven days in advance. If you are setting this feature to heat or cool the bunk
you MUST make sure your fan speed and temperature settings are programmed. This program
has a run time of three hours and will override all other AutoStart features. Once the program is
completed it will shut off and the last time/date will be stored. You will need to turn on this feature
each time you use it.

NOTE: If your RigMaster is running on another AutoStart program, e.g. Auto Temperature Control
or Low Battery Start-up program and surpasses the time and date set for AutoStart then the
APU will not start on this program.

Automatic Temperature Control

This control allows you to regulate the temperature in the bunk automatically providing additional
fuel savings. Fan and temperature settings MUST be set in order to activate this control. The
engine will NOT shut down if the fan setting is set to the off position.
If you are setting the Auto-start Temp to heat the bunk, the APU will start at 6 degrees below the
set temperature and run until set temperature is reached, then shut off.
If you are setting the Auto-start Temp to cool the bunk, the APU will start at 6 degrees above the
set temperature and run until set temperature is reached, then shut off.

NOTE: Fan speed has to be set to low, medium, high, automatic off, or automatic on before
the engine will shut down when using the AutoStart feature. The engine will not shut down if
the fan setting is set to off.

Low Battery Start Up

This feature replaces the low battery alarm and automatically starts up the RigMaster to charge the
truck batteries if they get below 12 volts ± .2 volts. The engine will shut down after 20 minutes of
charging. The engine will then restart after four minutes if the truck batteries are still below 12 volts
± 0.2 volts. When the truck batteries fail to sustain voltage and the truck batteries drop below 11.5V
the RigMaster will shut down and a system charging error message will display on the cabin
controller.

NOTE: Once the RigMaster starts on low battery AutoStart, it will not operate any system other
than the engine, charging system, and the 110V generator regardless of fan speed and
temperature settings.

13
RigMaster Power Principles of Operations – Control Panel
RMP14-6

Programming AutoStart Code

When you purchase the AutoStart feature you will be provided with a 4 character/digit code which
must be first programmed in to the cabin controller
Ensure the cabin controller is in low power mode. (Status light off)
Press and hold the MODE key and SELECT key at the same time for 5 seconds.
The display will show AutoStart code XXXX and the first character/digit will be flashing
Press UP or DOWN key to locate the first digit/character in the code
Press the SELECT key to accept the data and move to the next digit
Continue entering the code in the above manner until all four characters have been selected.
Once all four digits have been entered the system will accept the code and a message will
display………. Code Ok

AutoStart Code: ______________

Note: The AutoStart code will ONLY function on provided controller kit

Programming AutoStart

Press MODE key.


Press UP or DOWN key to find the Set AutoStart mode
Press SELECT key and Set Time AutoStart appears
Press SELECT key and day of week starts flashing
Press UP or DOWN key to adjust day of week
Press SELECT key and day of week will stop flashing and clock hour will starts flashing
Press UP or DOWN key to adjust clock hour
Press SELECT key and clock hour will stop flashing and clock minutes will start flashing
Press UP or DOWN key to adjust clock minutes
Press SELECT key and clock minutes will stop flashing and am/pm will start flashing
Press UP or DOWN key to adjust am/pm
Press SELECT key and am/pm will stop flashing and on/off will start flashing
Press UP or DOWN key to change on/off
Press SELECT key to save settings and return to menu mode
Press MODE key to return to normal mode

Note: Once you have set the program a # symbol will appear on the normal mode screen. If you
touch any keys once this program is activated it will default to OFF. This control will run a
continuous 3 hour program and then will default to OFF. You MUST set this program each time
you use it.

14
RigMaster Power Principles of Operations – Control Panel
RMP14-6

Set Auto Temperature Control

Press MODE key.


Press UP or DOWN key to find the Set AutoStart mode
Press SELECT key and Set Time AutoStart appears
Press UP or DOWN key to find the Set Auto Temperature mode
Press SELECT key and on/off will start flashing
Press UP or DOWN key to turn on/off
Press SELECT key to save setting and return to menu mode
Press MODE key to return to normal mode

Note: This is a one time program and will default to OFF. If you touch any keys once this program
is activated it will default to OFF. You MUST set this program each time you use it.

Set Auto Battery Control

Press MODE key.


Press UP or DOWN key to find the Set AutoStart mode
Press SELECT key and Set Time AutoStart appears
Press UP or DOWN key to find the Set Auto Battery
Press SELECT key and on will display
Press SELECT key to exit and return to the menu mode
Press MODE key to return to normal mode

Note: This setting can not be changed on cabin controller version 1.08 or higher, it is always set to
ON. This setting can be changed on older cabin controller versions.

Notes

15
RigMaster Power Principles of Operations – Control Panel
RMP14-6

ERROR MESSAGES LISTING

Error Displayed Error Description


Code
1 Safety Cover Open Safety cover of main unit is open.
Auxiliary engine will not start or run
until the cover is closed.
2 Oil Pressure Low Alarm, low oil pressure.
Auxiliary engine would start but will not
continue running unless oil pressure
becomes normal with 60 seconds of
engine start.
3 Battery Voltage Low Alarm, low battery voltage-start system
immediately.
4 Engine Run Failure Engine started but did not run properly.
Manual start attempts can occur.
5 Engine Overheated Engine will not run until temperature
becomes normal.
6 Electrical Problem Engine will not start until the system is
powered down and the problem has
been fixed.
7 Engine Start Failure Engine did not start. Automatic start is
disabled until operator presses select
button.
8 No Communication Error Communication between control panel
and power module is lost. Engine will
not start or run until communication is
re-established.
9 Main Engine Running Truck main engine is running.
RigMaster® Power APU will not run if
the main engine is already running.
10 Maximum Run Time Shutdown The engine was shut down the 3 hours
maximum run time has been exceeded.
11 Check Power Module Fuse Very low battery voltage detected,
check and replace the fuse if required.
12 Battery Charging Failure Battery voltage still low 2 minutes after
cranking. Auto and manual starts can
occur.
13 Battery Discharged Alarm, system will enter low power
mode. Auto and manual starts cannot
occur.
14 Check External Temperature External temperature sensor
Sensor disconnected from the power module.
15 External Temp Disable Limit Engine shut down since the external
temperature is outside the programmed
range.
16 Invalid Power Module Version Incompatible versions of the power
module and the cabin module.
17 Power Up Displayed when the power module is
starting up.

16
RigMaster Power Principles of Operations – Fuel System
RMP14-6

FUEL SYSTEM

The RigMaster® Power APU incorporates a low/high pressure system. In order to prevent the
vehicle engine from drawing the fuel from the RigMaster’s fuel supply line, an in-line check valve is
mounted at the point of connection on the vehicle's suction fitting and the RigMaster.

The RigMaster fuel supply line is connected to the Perkins engine feed pump, which in turn
supplies fuel to the filter/sediment bowl assembly and then in turn to the injection pump.

NOTE: THIS TYPE OF FUEL SYSTEM DOES NOT DE-AIRATE ITSELF.

All air must be bled from all of the hoses and components. There are air bleed screws located in
the fuel filter head assembly.

BLEEDING PROCEDURES
Low Pressure System

TOOLS NEEDED
Philips screwdriver #3

NOTE: THE LOW PRESSURE SYSTEM MUST BE COMPLETELY FREE OF AIR BEFORE THE HIGH PRESSURE
SYSTEM CAN BE BLED PROPERLY.

a) Position a container or shop wiper under the fuel sediment bowl in order to contain any
spillage of fuel.
b) Using a Philips screwdriver, loosen the right hand bleed screw located in the fuel filter head
(Location B).
c) Prime the fuel system using the manual primer pump lever located on the fuel feed pump
(Location F).
d) Continue to pump until the sediment bowl is full and clear flow of fuel is present at the bleed
screw.
e) Tighten the bleed screw in the fuel filter head (Location B).
f) Bleeding low pressure system is complete

17
RigMaster Power Principles of Operations – Fuel System
RMP14-6

I
A
G

B H

K
D

E J
F

FUEL SYSTEM - FIGURE 5

Legend:

A) Filter Feed Hose


B) Air Bleed Screw (Filter Housing)
C) Shut-Off Valve
D) Fuel Filter Element and Fuel Bowl
E) Fuel Supply Pump - Feed Pump
F) Manual Primer Pump Lever (Fuel Supply Pump)
G) Fuel Supply Hose
H) Fuel Return Hose (Injector Bleed-off)
I) Fuel Injector Nozzles
J) Fuel Injection Pump
K) Injector Pump Feed Line

18
RigMaster Power Principles of Operations – Fuel System
RMP14-6

BLEEDING PROCEDURES
High Pressure System-Injectors (see Figure 5)

TOOLS NEEDED
17mm Wrench
NOTE: THE LOW PRESSURE SYSTEM MUST BE COMPLETELY FREE OF AIR BEFORE THE HIGH PRESSURE
SYSTEM CAN BE BLED PROPERLY.

NOTE: IT IS RECOMMENDED THAT A SECOND PERSON ASSIST IN THE PERFORMANCE OF STEPS #1, #2, #3,
#6 AND #7. NEVER DISABLE OR BY-PASS THE SAFETY DEVICE.

1) Have a helper hold down the safety cover switch located on the unit.

2) Loosen both high-pressure line nuts located at the injectors using a 17mm wrench (Location I).

3) Start system using method described on Page 11.

NOTE: This procedure is meant only to remove air bubbles. APU will not start with nuts loosened.

4) If the air bubbles are still present after 30 seconds of cranking, re-start with nuts loose.

5) Tighten the left injector line nut using a 17mm wrench (Location I).

6) If the APU fails to start, Repeat steps 1 thru 5

7) As a final measure, it is recommended to bleed the fuel system with the engine running.

8) Slowly loosen one injector nut using a 17mm wrench (left nut first -Location I) at a time and
retighten quickly when engine speed drops. This will remove any remaining air. Be sure to
tighten the first injector nut (left nut) using a 17mm wrench before continuing to the next injector
nut (right nut).

19
RigMaster Power Principals of Operation – Maintenance
RMP14-6

PREVENTATIVE MAINTENANCE

Maintenance schedules listed below are for NORMAL road conditions and the specific hour
intervals must be adhered to. For SEVERE conditions perform the scheduled maintenance(s)
earlier.

SCHEDULED INTERVALS MAINTENANCE ITEMS


EVERY

50 200 500 600 800 1000 1600


hrs. hrs. hrs. hrs. hrs. hrs. hrs.

• Check coolant level. Top up with premixed coolant


only.
• Check concentration of coolant.
• Renew coolant, (fill slowly, ensure correct quantity is
used).
• Renew engine lubricating oil, (fill slowly, ensure right
quantity is used – 2 ltr. / 2 US qt. or 3 ltr. / 3 US qt.)
See note at the bottom of the page. To determine
the amount of oil used for your engine see page
22.
• Renew fuel filter element.
• Check tension of drive belts.
• Check drive belts for wear.
• Renew drive belts.
• Check and clean heater/AC unit filter
• Wash out internal engine compartment (see figure 12
for instructions)
• Check electrical systems. (see figure 12 for
instructions)
• Check all nuts/bolts for tightness.
• Check injectors for performance.
• Renew air filter element / Standard filter.
• Renew air filter element / Long Life filter.
• • • • • • • Check for and correct any leaks or engine damage.

NOTE: THESE PREVENTATIVE MAINTENANCE PERIODS APPLY TO AVERAGE CONDITIONS


OF OPERATION. IF NECESSARY USE SHORTER INTERVALS.
Note: The first oil change must be performed at 50 hours of service and
500 hour intervals there after.

20
RigMaster Power Principals of Operation – Maintenance
RMP14-6

OIL FILTER AIR FILTER

BRAND PART No. BRAND PART No.

AC Delco PF1233 RigMaster/Mann 00-C1140


Perkins 140516250
Wix 51396
K-Mart Motorvator K014477
Fram PH4386 ASSEMBLY
Baldwin B37 RigMaster 103002

FUEL FILTER FAN BELT

BRAND PART No. BRAND PART No.

Wix 33262 RigMaster RP8-009


NAPA 3262 Bando 2310 9.5 X 790LA
Perkins 130366040
Fram C7516
Baldwin PF937
AC Delco GF771

COMPRESSOR DRIVE BELT GENERATOR DRIVE BELT

BRAND PART No. BRAND PART No.

Gates 13A0875 RigMaster RP8-006


Dayco 51009 Gates 3VX420

GLOW PLUGS RECEIVER-DRIER

BRAND PART No. BRAND PART No.

Perkins 185366220 RigMaster RP9-027


Four Seasons 34334
Everco (UAP) A78239

21
RigMaster Power Principals of Operation – Oil Change
RMP14-6

OIL CHANGE - FIGURE 6

TOOLS REQUIRED:
3/8 Ratchet
17mm Socket
7/16 Socket

PROCEDURE:
1) Remove front cover (A).
2) Remove drain plug access cover (B) using a 7/16 socket.
3) Remove drain plug (C) using a 17mm socket.
4) Remove oil filter (D).
5) Install new oil filter.
6) Inspect drain plug gasket and replace if needed
7) Install and tighten drain plug using a 17mm socket.
8) Refill engine with (2 liters 2 US qts.) Or (3 liters / 3 US qt.) of new engine oil (E)**
NOTE: See page 22 for the size of the oil pan. This will tell you how much oil your engine
takes.
9) Check oil level with dipstick (F).
10) Run the RigMaster.
11) Recheck the oil Level and Add Oil if necessary. Note: make sure you don’t overfill the oil, if
over filled make sure the oil is drained to the proper level

**NOTE: Use only good quality lubricating oil which meets (and not exceeds) any of the
following specifications - API CC/CD/CE/CF/CF-4/CG-4 - ACEA E1/E2/E3

Recommended Viscosity Grades: 10W30 & 15W40 are most commonly used.

22
RigMaster Power Principals of Operation – Oil Change
RMP14-6

This oil pan holds 2 ltr./2 US qt. This engine oil pan is mounted flush with the engine block. Do not
go by the color of the engine. The first oil change must be performed at 50 hours of service & 500
hour intervals there after.

Oil Pan

This oil pan holds 3ltr./3US qt. This engine pan is mounted out from the engine block. Do not go by
the color of the engine. The first oil change must be performed at 50 hours of service & 500 hour
intervals thereafter.

Oil Pan

23
RigMaster Power Principals of Operation – Oil Change
RMP14-6

GENERATOR BELT REMOVAL / ADJUSTMENT - FIGURE 7

TOOLS REQUIRED:
7/16 Wrench
9/16 Wrench
9/16 Socket
7/16 Socket
3/8 Ratchet

PROCEDURE:
1) Remove bottom panel (A) using a 7/16 socket.
2) Remove generator cover (B) using a 7/16 socket.
3) To replace the generator belt, first - loosen and remove the compressor belt (see figure 8 for
details).
4) LOOSEN, but DO NOT REMOVE, the four (4) generator mounting bolts (C) using a 9/16
socket.
5) Using the two eye bolts (D) using a 7/16 wrench, gently pull the generator (E) outward and
evenly in the direction of the arrows until the belt deflection is less than 12 mm.(1/2").
6) Tighten the four generator bolts (C) using a 9/16 wrench & a 14mm socket, replace and adjust
the compressor belt (see figure 8 for details).
7) Replace the generator cover (B) using a 7/16 socket and the bottom panel (A) using a 7/16
socket.

24
RigMaster Power Principals of Operation – Compressor Belt
RMP14-6

D A C

COMPRESSOR BELT REMOVAL / ADJUSTMENT - FIGURE 8

TOOLS REQUIRED:
9/16 Wrench
3/8 Ratchet
9/16 Socket
16 Inch pry bar

PROCEDURE:

1) Remove the front cover.


2) Loosen the adjustment bolt (A) using a 9/16 socket & a 9/16 wrench and the Pivot Bolt (B)
using a 9/16 socket.
3) Rotate the compressor (C) towards you using a 16 inch pry bar (D) until the belt deflection is
less than 6 mm. (1/4").
4) Note: When using the pry bar, put the pry bar between the top left ear on the compressor & the
flywheel & push the compressor downwards.
5) When the belt is sufficiently tight, tighten the adjustment bolt (A) using a 9/16 socket & a 9/16
wrench, and then tighten the pivot bolt (B) using a 9/16 socket.

25
RigMaster Power Principals of Operation – Fan Belt
RMP14-6

D E C

FAN BELT REMOVAL / ADJUSTMENT - FIGURE 9

TOOLS REQUIRED:
12mm Wrench
3/8 Ratchet
12mm Socket
7/16 Socket
16 inch pry bar

PROCEDURE:

1) Remove the one piece fan side chamber using a 7/16 socket.
2) Loosen, but DO NOT REMOVE, the adjustment bolt (C) using a 12mm wrench & a 12mm
socket. Then loosen the pivot bolt (D) using a 12mm socket.
3) To remove the fan belt, slide the alternator (E) down towards the back of the engine & remove
the fan belt.
4) Install the new fan belt & slide the alternator (E) up towards the top of the engine using a 16
inch pry bar & until the belt deflection is less than 6 mm. (1/4").
5) When the fan belt is tight, tighten the adjustment bolt (C) using a 12mm wrench & 12mm
socket. Then tighten the pivot bolt (D) using a 12mm socket.
6) Reinstall the one piece fan side chamber using a 7/16 socket. Make sure the ring on the one
piece side chamber does not touch the engine fan blade. NOTE: Inspect the fan blade for
broken blades or worn tips; if the blade is damaged, check the engine mounts & bottom
stiffeners. (loose bolts or worn engine mounts).

26
RigMaster Power Principals of Operation – Breaker Reset
RMP14-6

RESETTING THE 20 AMP BREAKERS - FIGURE 10

NOTE: The cover is shown removed for clarity purposes only.

WARNING: CORRECT THE ELECRICAL OVERLOAD PRIOR TO THE RESETTING OF EITHER BREAKER.

TOOLS NEEDED:
Flat head screwdriver

PROCEDURE:

1) Remove the Rubber Plugs (A) from the Generator Cover (E) using a flat head screwdriver.

2) Locate the Breakers (D) located on the front of the Electrical Connection Box (B) mounted on
top of the Generator (C).

3) Insert the screwdriver and depress the Buttons (D), which protrudes from the Electrical
Connection Box (B) to reset the breakers.

27
RigMaster Power Principals of Operation – Component Locations
RMP14-6

MAIN COMPONENTS AND PART LOCATIONS - FIGURE 11

28
RigMaster Power Principals of Operation – Cleaning Instructions
RMP14-6

CLEANING INSTRUCTIONS

The RigMaster® Power Auxiliary Power Unit should be periodically inspected and any
accumulation of road contaminants (such as: paper; plastic; dirt; oil; etc.) must be removed. Three
main components, as outlined below, must be kept clean and free of contaminants and/or debris.
Refer to Figure 12 for location of components.

MAIN UNIT GENERAL CLEANING (See Figure 12)

a) Using a power spray wand, wash down the exterior of the main unit especially
all louver panels (air intake / exhaust openings).

b) Remove the front cover and wash down the interior of the main unit, holding
the spray wand no closer than twelve inches (24") away from any component.

c) Before replacing the front cover you will have to spray all electrical connections & sensors
to prevent the connections & sensors from corroding. Make sure the engine compartment is
dry first. Using battery sealant, spray the positive & negative post, glow plugs, run solenoid.
(see below for areas to spray with battery sealant). NOTE: The following parts are not
shown in the picture, but make sure that the green wire to the starter solenoid & the positive
post on the alternator & starter is sprayed with battery spray. For the low oil sensor, high
temperature sensor & the binary switch spray them with die electrical grease. Note: Make
sure the boots are installed back on to the sensors.

Positive & Negative Post


High Temperature Sensor
Low Oil Sensor
Glow Plugs
Run Solenoid
Binary Switch

MAIN UNIT - FIGURE 12

29
RigMaster Power Principals of Operation – Cleaning Instructions
RMP14-6

GENERATOR CLEANING (See Figure 13)

TOOLS NEEDED:
7/16 SOCKET

PROCEDURE:

a) Remove the Generator Cover using a 7/16 socket and inspect for any accumulation of dirt
or oil especially at the generator air inlet and outlet openings.
b) Using a compressed air line and nozzle, blow out the generator compartment.
c) Using a clean cloth, soak up any oil or other liquids.
d) Replace the Generator Cover and secure using a 7/16 socket.

GENERATOR - FIGURE 13

HEATER / AIR CONDITIONING UNIT (See Figure 14)

30
RigMaster Power Principals of Operation – Cleaning Instructions
RMP14-6

a) Unscrew the two thumb nuts (A) & remove the air filter out of the HVAC box.
b) Wash the air filter using soapy water or blow clean with compressed air.
c) Re-insert the (dry) air filter to the filter cover & tighten down the two thumb nuts.

A A

HEATER / AIR CONDITIONER UNIT - FIGURE 14

31
RigMaster Power Principals of Operation – Trouble Shooting
RMP14-6
ENGINE Troubleshooting
SYMPTOM PROBABLE CAUSE REMEDY/COMMENT

1. Starter relay 1. Check for power at relay


2. Starter motor faulty during starting sequence
3. Broken engine ground 2. Check for power at starter
Engine does not crank strap solenoid
3. Replace strap
4. Battery connections loose
4. Tighten connections
5. Low battery voltage
5. Charge batteries

1. Air filter
1. Check air filter
2. Speed sensor
2. Check speed sensor gap:
3. Glow plug or Glow plug
0.025”, Ohms: 625 +/- 75
relay
Engine cranks but does not 3. Check for power @ the glow
4. Fuel
start plug relay
5. Run solenoid not operating
4. Check if the fuel bowl is full &
6. Governor assembly
that the filter is clean
(spring)
5. Check 12v at run solenoid
6. See Perkins manual

1. Check air filter


1. Air filter
2. Check if the fuel bowl is full &
Engine hard to start 2. Fuel
that the filter is clean
3. Glow plugs
3. Check for power @ the glow
plug relay

1. Damaged / corroded 1. Replace or clean the battery


battery connections connections
Engine Cranks Slowly 2. Faulty starter 2. Check connections at the
3. Faulty A/C Compressor starter
4. Faulty generator 3. Compressor seized
4. Generator seized

1. Speed sensor 1. Check speed sensor Gap:


2. Clogged fuel filter 0.025”, Ohms: 625 +/- 75
3. Excessive load on the 2. Replace filter
Engine Starts & Stalls
motor; generator, a/c 3. Unplug the block heater when
compressor using the a/c compressor
4. Damaged or loose wiring 4. Inspect wiring connection &
connections connectors

32
RigMaster Power Principals of Operation – Trouble Shooting
RMP14-6
SYMPTOM PROBABLE CAUSE REMEDY/COMMENT

1. Check air filter


1. Air filter
Engine Shuts Down 2. Check fuel filter
2. Fuel filter
3. Replace fuse
3. Blown fuses
4. Inspect condition of wiring and
4. Damaged or loose wiring
wiring connections

1. Excess engine oil 1. Inspect & correct oil level


White or blue smoke
2. Coolant in combustion 2. Check for blown head gasket
chamber

Dark grey/black smoke 1. Over loading 1. Unplug 120 volt appliances


2. Clogged air filter & block heater
2. Check air filter

1. Air filter c
1. Check air filter
2. Fuel filter
Engine runs rough 2. check fuel filter
3. Fuel leak
3. Inspect all hoses & clamps
4. Worn/contaminated fuel
4. Inspect Injectors
injectors
5. Replace or rebuild the engine
5. Engine in poor condition
1. Oil seals leaking 1. Replace crankshaft seals
2. Leaking drain plug (seals leaking is do to having
Loss of engine oil 3. Pinched or clogged too much oil in the system)
breather tube 2. Replace oil pan plug gasket
4. Engine worn or in poor 3. Repair or replace the tube
condition 4. Replace or rebuild the engine

33
RigMaster Power Principals of Operation – Trouble Shooting
RMP14-6
CHARGING SYSTEM
SYMPTOM PROBABLE CAUSE REMEDY/COMMENT

1. Loose or broken belt


Batteries not charging 1. Tighten or replace belt
2. Damaged or loose
2. Inspect wiring
battery connections
3. Check alternator
3. Faulty alternator
4. Test batteries
4. Battery in poor condition

Batteries overcharging
1. Faulty Alternator 1. Check Alternator output

34
RigMaster Power Principals of Operation – Trouble Shooting
RMP14-6

FUEL
SYMPTOM PROBABLE CAUSE

1. Loose fuel fittings


Fuel odor/leak 2. Damaged fuel line or fuel filter bowl
3. Fuel injection pump leak

35
RigMaster Power Principals of Operation – Trouble Shooting
RMP14-6

COOLING SYSTEM
SYMPTOM PROBABLE CAUSE REMEDY/COMMENT
1. Add coolant
2. Tighten or replace
1. Coolant level low
3. Clean radiator fins
2. Engine fan belts loose
4. The elec fan only engages
3. Radiator fins blocked
Engine overheating when the compressor clutch
(external)
engages.
4. Elec fan
5. Clean the radiator
5. Faulty engine thermostat
6. Replace the by-pass
6. Faulty by-pass valve
thermostat valve
7. Overloading the engine
7. Reduce 110v load (eg. Block
heater)

1. Block heater not plugged


1. Plug in block heater
Engine overcooling in & working
2. Check the by-pass valve
2. Faulty by-pass valve
3. Check the thermostat
3. Faulty thermostat

1. Check coolant level regularly


2. Check coolant hoses from
RigMaster to the HVac
Coolant loss 1. Coolant system over filled system
2. External coolant leak 3. Check internal coolant hoses
3. Internal coolant leak inside the engine
4. Blown head gasket compartment
4. Replace the head gasket
Note: the cylinder head
should be machined

1. Water pump not operating 1. Check the belt tension


properly 2. Check for kinks in the coolant
Poor circulation
2. Cooling system restricted hoses

36
RigMaster Power Principals of Operation – Trouble Shooting
RMP14-6

HVAC
SYMPTOM PROBABLE CAUSE REMEDY/COMMENT
1. Clean filter
2. Remove obstruction & tell
1. HVac filter
the drive to keep the filter
2. HVAC air intake obstructed
clear
eg. Cloths or plastic bag
3. Reduce the hose by
3. Excessive duct hose
Poor air flow extending the hose to
4. Poor placement of vent
maximum length
5. Faulty blower motor
4. Relocate the vent
6. Ducted through trucks
5. Check for power & ground
ventilation system
6. See install manual for
ducking the vents
1. Main engine block heater
1. Engine overcooling
not plugged in
2. Water valve Faulty
Little or no hot air 2. Check water valve operation
3. Airlock in coolant or low in
3. Bleed system & fill coolant
coolant
4. Replace the by-pass valve
4. Faulty coolant by-pass valve
5. Flush complete cooling
5. Cooling system blocked
system

1. Check the compressor


clutch fuse
1. Compressor not working 2. Tighten or replace the drive
2. Compressor drive belt loose belts
Little or no cold air or damaged 3. Clean radiator/condenser
3. Condenser or radiator fins using compressed air
blocked 4. Check pressures using
4. A/C system leak gages
5. Elec fan not operating 5. Check the fuse
6. Evaporator core frozen 6. Check the temperature
switch & the location of the
probe

37
RigMaster Power Principals of Operation – Trouble Shooting
RMP14-6

120 VOLT ELECTRICAL SYSTEMS


SYMPTOM PROBABLE CAUSE REMEDY/COMMENT

1. Reset the breakers.


1. Breakers tripped
2. Check the belt
No power to receptacles 2. Generator drive belt loose
3. Check all connections
(Bunk and block heater) or damaged
4. Check the generator
3. Wiring damaged
out put (61 Hertz with
4. Internal damage to
no load)
generator

Generator continually trips


1. Circuit overloaded 1. Check power rating of
(20A or 2400 W max) appliances
2. Short circuit

38
RigMaster Power Warranty
RMP14-6

THE LIMITED WARRANTY


This limited warranty applies to the RigMaster® Auxiliary Power unit (“APU”) which consists of the
following components:
1) The generator set
2) The generator set control panel
3) The combination heater/air conditioner unit

12 MONTH WARRANTY COVERAGE


RigMaster Power Corp. warrants that, under normal service and use, the RigMaster® Power APU
will be free from defects in material and workmanship for twelve (12) months from the date of
installation, subject to all terms and conditions, limitations and provisions of this limited warranty.
This limited warranty is governed by the laws of the Province of Ontario, Canada, and any claims
or disputes arising out of this limited warranty shall be governed by the laws of the Province of
Ontario, Canada.

24 MONTH OR 4000 HOUR WARRANTY COVERAGE


STARTING JAN, 1-2006 Perkins Engine Model 402.5, RigMaster® Power Model RMP 14-6 Serial
Number 03202 and higher will have a RigMaster warranty of 24 months or 4000 hours (Whichever
comes first) from the ‘in-service date’ as stated in the RigMaster Warranty Policy.

WARRANTY OBLIGATION
During the warranty period, RigMaster Power Corp. will repair or replace, at its option, the
RigMaster® Power APU components, which consist of the generator, the control panel, or the
combination heater/air conditioner. Repair or replacement will be completed at an authorized
dealer or company owned facility, upon presentation of proof of purchase and determination by
RigMaster Power Corp. or its authorized dealer that a component is defective or has failed under
normal service and use, at no charge to the owner of the RigMaster® Power APU, within the first
12 month warranty period package or the 24 month /4000 hour whichever comes first warranty
period package.

DISCLAIMER OF OTHER WARRANTIES


RIGMASTER POWER CORP., INCLUDING ITS AGENTS AND AUTHORIZED DEALERS,
MAKES NO OTHER WARRANTIES AND EXPRESSLY DISCLAIMS ALL OTHER
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ALL WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. No person, firm, or
representative is authorized to assume any obligation or make any warranty on behalf of
RigMaster Power Corp. other than the limited warranty as stated herein.

MAINTENANCE
The RigMaster® owner’s manual lists all maintenance functions required to validate this limited
warranty. PLEASE NOTE THAT FAILED COMPONENTS DUE TO POOR OR IMPROPER
MAINTENANCE WILL NOT BE COVERED BY THIS LIMITED WARRANTY. Where a dispute
arises regarding proper maintenance, the manufacturer reserves the right to request proof in the
form of receipts for maintenance, and any other records of service to establish that proper
maintenance has been performed, as per the service and repair manual and/or dealer
communications.

39
RigMaster Power Warranty
RMP14-6

INSTALLATION
It is the responsibility of the installer and the owner to ensure that all RigMaster® APU components
are in proper working order at the time of installation. The manufacturer is not responsible for failed
components that are a result of improper installation.
In order to validate your RigMaster® Power APU warranty, the APU must be either installed by an
authorized RigMaster dealer or must be inspected and certified by an authorized RigMaster dealer
within 30 days of purchase. A RigMaster Installation Check List must be completed and registered
by the dealer to certify the installation. Cost to certify is at the owner’s expense. For APU’s not
installed by an authorized dealer; the warranty, if validated, will be from the date of purchase, not
the date of certification.

WARRANTY VOIDED OR TERMINATED


Any modification to the RigMaster® Power without the written authorization from the manufacturer
will void this limited warranty. Repair, replacement, or maintenance, using other than approved
parts, will be cause to terminate this limited warranty.

EXCLUSIONS FOR LIMITED WARRANTY


The costs of normal maintenance such as, but not limited to tune-ups, adjustments, and
inspections, tightening of clamps, fasteners, hoses, the replacement of belts, fuel, air, oil and filters
are excluded from this limited warranty.

LIMITATION OF REMEDIES
The remedy of repair or replacement as set forth herein is the sole exclusive remedy available to
the purchaser or user of the RigMaster® Power APU. RigMaster Power Corp. disclaims and shall
not be liable or responsible to the owner or user of the RigMaster® APU or any other person for
incidental, consequential, direct, indirect, special or general damages of any kind arising out of or
in any way related to the use of the RigMaster® APU including, but not limited to towing charges,
accident repairs, road calls, traveling expenses, loss of revenue profits, loss of truck use or
damage to persons or property. No claim of any kind asserted against RigMaster® APU, whether
asserted under legal theories of negligence, strict liability, warranty, or any other common law or
statutory basis, shall be greater in amount that the purchase price of the RigMaster® with respect
to which damages are claimed.

INDEMNITY
The user and owner of the RigMaster® APU agree to indemnify and hold RigMaster Power Corp.
harmless from any and all claims, expenses, suits or liability of any nature whatsoever asserted
against RigMaster Power Corp. arising out of or in any way related to negligence on the part of the
user or owner of the RigMaster® APU.

WARRANTY CLAIMS
Failed or defective parts must be inspected and their replacement installed by an authorized
RigMaster® dealer. The manufacturer reserves the right to inspect failed or defective parts prior to
a decision on any claim under this limited warranty. It is the owner’s responsibility to act promptly
in submitting any such claim.

40
RigMaster Power Warranty
RMP14-6

TRANSFER OF WARRANTY
Where the vehicle with the RigMaster® APU has been sold by the first owner to a second owner
and the RigMaster® has not been removed, this limited warranty is transferable from the original
owner to a second owner with whatever portion of the limited warranty that remains from the date
of sale to the first owner. Where the RigMaster® APU has been removed from the vehicle in which
it was originally installed, and sold by the first owner to a second, re-installation is required to be
completed by an authorized dealer in order to validate the remaining portion of this limited
warranty. Where the original owner transfers the RigMaster® to a new vehicle, the installation must
be completed by an authorized dealer to validate whatever is remaining of this limited warranty.

WARRANTY POLICY
RigMaster Power Corp. (RIGMASTER POWER CORP.) warrants that, under normal service and
use, the RigMaster® Power APU will be free from defects in material and workmanship as stated.

During the warranty period RIGMASTER POWER CORP. will provide the exclusive remedy of
ensuring the repair or replacement of those parts which are demonstrated to be defective in
material or workmanship.

The purpose of the warranty is to provide the owner with free repair and replacement of defective
parts in the manner outlined in the following policy. This remedy does not apply to normal wear of
service parts, improper installation, deterioration, modification or economic loss.

41
RigMaster Power Warranty
RMP14-6

Customer Assistance Procedure

To obtain warranty repairs you must request the needed repairs within the warranty period from
an authorized RigMaster dealer.

A reasonable time must be allowed to perform the warranty repair after taken the APU to an
authorized dealer location. Repairs will be performed during normal business hours.

To ensure your complete satisfaction the following procedures must be followed in the event
You have a problem.

1- Contact the nearest (most convenient) RigMaster dealer to schedule a warranty service
appointment. Prior to contact have the following information available

→ APU serial number


→ Hour meter reading
→ In service (Purchase) date
→ Nature of problem

2- Deliver APU to dealer for service. Upon completion of repairs review and sign the dealer
work order, keeping a copy for reference.

3- Frequently, customer concerns are a result of a breakdown in communications and can


be quickly resolved at the dealer level.

4- If you are still not satisfied, present the entire matter in writing to:

RigMaster Warranty Administration


11 Diesel Drive
Toronto, Ontario
Canada, M8W-4Z7
Fax: (416) 201-7532

CALIFORNIA
Proposition 65 Warning
Diesel engine exhaust and some of its constituents are known by the
State of California to cause cancer, birth defects and other reproductive harm.

42
RigMaster Power Maintenance Record
RMP14-6

MAINTENANCE RECORD

MAINTENANCE PERFORMED
DATE Hour Meter 200 400 600 800 1000 1600 REMARKS
Reading hrs. hrs. hrs. Hrs. hrs. hrs.

43
RigMaster Power Maintenance Record
RMP14-6

MAINTENANCE RECORD

MAINTENANCE PERFORMED
DATE Hour Meter 200 400 600 800 1000 1600 REMARKS
Reading hrs. hrs. hrs. hrs. hrs. hrs.

44
RigMaster Power Maintenance Record
RMP14-6

MAINTENANCE RECORD
MAINTENANCE PERFORMED
DATE Hour Meter 200 400 600 800 1000 1600 REMARKS
Reading hrs. hrs. hrs. hrs. hrs. hrs.

45
RigMaster Power Notes
RMP14-6

NOTES

46
RigMaster Power Notes
RMP14-6

47