Underfloor Air Distribution Linear Terminal


MODEL: CLMIT
DESCRIPTION:
CLMIT (Continuous Linear Modular Integrated
Terminal) is a linear diffuser terminal, available in
constant and variable volume air flow configurations.
The underfloor terminal features 20 gauge (1mm)
galvanized steel construction, pre-painted flat black.
Optional air valves use time modulation to vary total
air supplied to a conditioned space. Air velocity is
constant any time the valve is open; the short time
duration between open/close cycles produces the
effect of contiuous air delivered to the occupied
space. They are rated for 24V (18-30VAC) operation;
one (1) PAP-1 Plug & Play Cable is included per air
valve. Optional extended high performance air valves
are available (specify on order).
Optional duct connections are available in multiple
sizes and configurations. Ducted air flow capacity
is derived from the source; output is dependent on
ducting arrangement and fan capability.
The linear grille is available as extruded aluminum or
stainless steel, in a variety of sizes and configurations.
Ten (10) standard colors are available; custom colors
and finishes can be provided to match architectural
design (specify on order).

AirFixture ©2020 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V200131 1
DATA SHEET

Underfloor Air Distribution Linear Terminal


MODEL: CLMIT
UNIT DETAIL:

1. Linear grille
(optional extruded aluminum or
stainless steel; specify on order)
2. 20 guage (1mm) galvanized
steel casing, pre-painted black
3. 3/4" (19mm) support flanges
(optional; specify on order)
4. Duct connections
(optional; specify on order)
5. VAV air valves
3 4 2 5 (optional; specify on order)
6. Support pedestals / brackets on
nominal 36" (914mm) centers
(optional; specify on order)

H
L STANDARD LENGTH OPTIONS
in 24 36 48 60 72 84 96 108 120
W mm 610 914 1219 1524 1829 2134 2438 2743 3048

W STANDARD WIDTH OPTIONS H STANDARD HEIGHT OPTIONS


in 6 8 10 12 in 6 8 10 12
mm 152 203 254 305 mm 152 203 254 305

ALL DIMENSIONS NOMINAL ± 0.1" (2.5mm)

AirFixture ©2020 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V200131 2
DATA SHEET

Underfloor Air Distribution Linear Terminal


MODEL: CLMIT
FEATURES:
• 20 Gauge (1mm) galvanized steel terminal housing, • Optional air valves (maximum size / number of air
pre-painted flat black valves based on unit length)
- DC synchronized magnetic motor
• Optional terminal dimensions available (specify on order)
- Factory programmed multi-function circuit board
• Multiple grille configurations available for varying control strategies
- Extruded aluminum / stainless steel (304 / 316 Series) - Modular Plug & Play power and control connections
- Ten (10) standard colors; additional colors and finishes
• Optional duct connections (size, shape, quantity)
available at architect’s choice (specify on order)
• Optional 3/4" (19mm) support flanges
• Optional support pedestals / brackets (brackets factory
mounted; pedestals furnished loose for field installation)

SPECIFICATIONS:
Application: Underfloor Heating / Cooling | Raised Access Floor Systems
Terminal Dimensions: Specify on Order
Terminal Construction: Galvanized Steel | 20 Gauge (1mm) | Pre-Painted Black
Grille Configuration: Extruded Aluminum | 304 / 316 Series Stainless Steel (Specify On Order)
Standard Capacity: 13" (330mm) Standard air Valve | 150 cfm @ 0.05 in. w.c. (255 m3/hr @ 12.5 Pa)
Air Flow (Nominal) OPTIONAL: 2 Air Valves = 300 cfm (510 m3/hr) | Minimum Trough Size: 4' (1.2m)
3 Air Valves = 450 cfm (765 m3/hr) | Minimum Trough Size: 6' (1.8m)
4 Air Valves = 600 cfm (1020 m3/hr) | Minimum Trough Size: 7' (2.1m)
5 Air Valves = 750 cfm (1275 m3/hr) | Minimum Trough Size: 8' (2.4m)
High Capacity: 22" (559mm) Extended Air Valve | 300 cfm @ 0.05 in. w.c. (510 m3/hr @ 12.5 Pa)
Air Flow (Nominal) OPTIONAL: 2 Air Valves = 600 cfm (1020 m3/hr) | Minimum Trough Size: 6' (1.8m)
3 Air Valves = 900 cfm (1530 m3/hr) | Minimum Trough Size: 8' (2.4m)
4 Air Valves = 1200 cfm (2040 m3/hr) | Minimum Trough Size: 10' (3.0m)

AirFixture ©2020 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V200131 3
DATA SHEET

Underfloor Air Distribution Linear Terminal


MODEL: CLMIT
EXAMPLE CONFIGURATIONS:
Plenum Air Only Heating Only
Plenum Openings Duct Connections

SU SU
(PLPPLY (HEPPLY
EN AIR
UM ATI AIR
) NG
)

SU
(PLPPLY SU
EN AIR (HEPPLY
UM ATI AIR
) NG
)

Cooling Only Heating & Cooling


Air Valves Duct Connections + Air Valves

SU SU
(COPPLY (COPPLY
OL AIR OL AIR
ING ING
) )

SU SU
(COPPLY (HEPPLY
OL AIR ATI AIR
ING NG
) )

AirFixture ©2020 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V200131 4
DATA SHEET

Underfloor Air Distribution Linear Terminal


MODEL: CLMIT
C LO - 0 6 - 02 4 - 0 6 - 0 0 - 1 V S

PRODUCT OPENING DIMENSION


DESCRIPTION Air Valve (Length)
Continuous S = Standard Capacity (13")
Linear Cooling L = High Capacity (22")
Only
Duct Connection
(Ellipsoid / Round Diameter)
(Rectangle Height)
TERMINAL WIDTH A = 4"
06 = 6" (152mm) B = 5"
08 = 8" (203mm) C = 6"
10 = 10" (254mm) D = 7"
12 = 12" (305mm) E = 8"
F = 9"
G = 10"
TERMINAL LENGTH H = 11"
024 = 24" (610mm) I = 12"
036 = 36" (914mm)
048 = 48" (1219mm)
060 = 60" (1524mm) OPENING DESCRIPTION
072 = 72" (1829mm) V = VAV Air Valve
084 = 84" (2134mm) Duct Connection
096 = 96" (2438mm) L = Ellipsoid
108 = 108" (2743mm) R = Round
120 = 120" (3048mm)
Duct Connection
(Rectangle Width)
A = 4"
TERMINAL HEIGHT B = 5"
06 = 6" (152mm) C = 6"
08 = 8" (203mm) D = 7"
10 = 10" (254mm) E = 8"
12 = 12" (305mm) F = 9"
G = 10"
H = 11"
TERMINAL FLANGE CONFIGURATION I = 12"
00 = Fully Flangeless
20 = Two (2) Flanges (Sides Only)
3L = Three (3) Flanges (Sides + Left End) AIR FLOW OPENINGS
3R = Three (3) Flanges (Sides + Right End) 1 = One (1) Opening
40 = Four (4) Flanges (All Sides + Ends) 2 = Two (2) Openings
3 = Three (3) Openings
4 = Four (4) Openings
5 = Five (5) Openings

AirFixture ©2020 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V200131 5
DATA SHEET

Underfloor Air Distribution Linear Terminal


MODEL: CLWMIT
DESCRIPTION:
CLWMIT (Continuous Linear Water Modular Integrated Terminal) is a hydronic heating / air cooling
linear diffuser package, for use in raised access floor systems. The underfloor terminal features 20
gauge (1mm) galvanized steel construction, pre-painted flat black.
The hydronic fin pack has been rated in accordance with AHRI Standard 410; rows are 1/2"Ø (13mm)
copper tubing with 1"Ø (25mm) supply and return connections. Aluminum fin size and spacing, as well as
overall finned length vary based on overall terminal dimensions and performance specification. Associated
water control valve is field furnished and installed by others.
Optional air valves use time modulation to vary total air
supplied to a conditioned space. Air velocity is constant
any time the valve is open; the short time duration between
open/close cycles produces the effect of contiuous
air delivered to the occupied space. They are rated for
24V (18-30VAC) operation; one (1) PAP-1 Plug & Play
Cable is included per air valve. Optional extended high
performance air valves are available (specify on order).
Optional duct connections are available in multiple
sizes and configurations. Ducted air flow capacity is
derived from the source; output is dependent on ducting
arrangement and fan capability.
The linear grille is available as extruded aluminum or
stainless steel, in a variety of sizes and configurations.
Ten (10) standard colors are available; custom colors and
finishes can be provided to match architectural design
(specify on order).

AirFixture ©2020 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V200305 1
DATA SHEET

Underfloor Air Distribution Linear Terminal


MODEL: CLWMIT
UNIT DETAIL:

1. Linear grille
(optional extruded aluminum or
stainless steel; specify on order)
2. 20 guage (1mm) galvanized
steel casing, pre-painted black
3. 3/4" (19mm) support flanges
2 4 3 (optional; specify on order)
4. Hydronic heating fin pack
5. 1"Ø (25mm) water supply / return
connections
6. Duct connections
(optional; specify on order)
7. VAV air valves
5 6 7 (optional; specify on order)
8. Support pedestals / brackets on
nominal 36" (914mm) centers
(optional; specify on order)

L STANDARD LENGTH OPTIONS


in 24 36 48 60 72 84 96 108 120

H mm 610 914 1219 1524 1829 2134 2438 2743 3048

W STANDARD WIDTH OPTIONS H STANDARD HEIGHT OPTIONS


in 6 8 10 12 in 6 8 10 12
mm 152 203 254 305 mm 152 203 254 305
W
ALL DIMENSIONS NOMINAL ± 0.1" (2.5mm)

AirFixture ©2020 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V200305 2
DATA SHEET

Underfloor Air Distribution Linear Terminal


MODEL: CLWMIT
FEATURES:
• 20 Gauge (1mm) galvanized steel terminal housing, • Optional duct connections (size, shape, quantity)
pre-painted flat black • Optional support pedestals / brackets (brackets factory
• Optional terminal dimensions available (specify on order) mounted; pedestals furnished loose for field installation)
• Multiple grille configurations available • Optional 3/4" (19mm) support flanges
- Extruded aluminum / stainless steel (304 / 316 Series) • Hydronic fin pack (performance rated in accordance
- Ten (10) standard colors; additional colors and finishes with AHRI Standard 410)
available at architect’s choice (specify on order) - Variable finned length (based on terminal length
• Optional air valves (maximum size / number of air valves and performance specification)
based on unit length) - 1/2"Ø (13mm) copper rows
- DC synchronized magnetic motor - 1"Ø (25mm) supply / return connections
- Factory programmed multi-function circuit board • “Heating-Only” option available
for varying control strategies
- Modular Plug & Play power and control connections

SPECIFICATIONS:
Application: Underfloor Heating / Cooling | Raised Access Floor Systems
Terminal Dimensions: Specify on Order
Terminal Construction: Galvanized Steel | 20 Gauge (1mm) | Pre-Painted Black
Grille Configuration: Extruded Aluminum | 304 / 316 Series Stainless Steel (Specify On Order)
Standard Capacity: 13" (330mm) Standard air Valve | 150 cfm @ 0.05 in. w.c. (255 m3/hr @ 12.5 Pa)
Air Flow (Nominal) OPTIONAL: 2 Air Valves = 300 cfm (510 m3/hr) | Minimum Trough Size: 4' (1.2m)
3 Air Valves = 450 cfm (765 m3/hr) | Minimum Trough Size: 6' (1.8m)
4 Air Valves = 600 cfm (1020 m3/hr) | Minimum Trough Size: 7' (2.1m)
5 Air Valves = 750 cfm (1275 m3/hr) | Minimum Trough Size: 8' (2.4m)
High Capacity: 22" (559mm) Extended Air Valve | 300 cfm @ 0.05 in. w.c. (510 m3/hr @ 12.5 Pa)
Air Flow (Nominal) OPTIONAL: 2 Air Valves = 600 cfm (1020 m3/hr) | Minimum Trough Size: 6' (1.8m)
3 Air Valves = 900 cfm (1530 m3/hr) | Minimum Trough Size: 8' (2.4m)
4 Air Valves = 1200 cfm (2040 m3/hr) | Minimum Trough Size: 10' (3.0m)

AirFixture ©2020 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V200305 3
DATA SHEET

Underfloor Air Distribution Linear Terminal


MODEL: CLWMIT
C LW - 0 6 - 02 4 - 0 6 - 0 0 - 1R - 1 V S

PRODUCT OPENING DIMENSION


DESCRIPTION Air Valve (Length)
Continuous S = Standard Capacity (13")
Linear L = High Capacity (22")
Water Heating
Duct Connection
(Ellipsoid / Round Diameter)
(Rectangle Height)
TERMINAL WIDTH A = 4"
06 = 6" (152mm) B = 5"
08 = 8" (203mm) C = 6"
10 = 10" (254mm) D = 7"
12 = 12" (305mm) E = 8"
F = 9"
G = 10"
TERMINAL LENGTH H = 11"
024 = 24" (610mm) I = 12"
036 = 36" (914mm)
048 = 48" (1219mm)
060 = 60" (1524mm) OPENING DESCRIPTION
072 = 72" (1829mm) V = VAV Air Valve
084 = 84" (2134mm) Duct Connection
096 = 96" (2438mm) L = Ellipsoid
108 = 108" (2743mm) R = Round
120 = 120" (3048mm)
Duct Connection
(Rectangle Width)
A = 4"
TERMINAL HEIGHT B = 5"
06 = 6" (152mm) C = 6"
08 = 8" (203mm) D = 7"
10 = 10" (254mm) E = 8"
12 = 12" (305mm) F = 9"
G = 10"
H = 11"
TERMINAL FLANGE CONFIGURATION I = 12"
00 = Fully Flangeless
20 = Two (2) Flanges (Sides Only)
3L = Three (3) Flanges (Sides + Left End) AIR FLOW OPENINGS
3R = Three (3) Flanges (Sides + Right End) 1 = One (1) Opening
40 = Four (4) Flanges (All Sides + Ends) 2 = Two (2) Openings
3 = Three (3) Openings
4 = Four (4) Openings
HEATING OPTIONS 5 = Five (5) Openings
1R = One (1) Row Hydronic Fin Pack
3R = Three (3) Row Hydronic Fin Pack
5R = Five (5) Row Hydronic Fin Pack

AirFixture ©2020 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V200305 4
DATA SHEET

Underfloor Air Distribution Linear Terminal


MODEL: CLEMIT
DESCRIPTION:
CLEMIT (Continuous Linear Electric Modular Integrated Terminal) is an electric heating / air
cooling linear diffuser package, for use in raised access floor systems. The underfloor terminal features
20 gauge (1mm) galvanized steel construction, pre-painted flat black.
The sheathed-type electric heater is available up to 2.0kW standard, with additional custom sizes available
(specify on order). A 24VAC control transformer will power other devices up to standard 40VA (100VA option
available). A single-point electrical power connection and unit-mounted disconnect are included.
Optional air valves use time modulation to vary total air
supplied to a conditioned space. Air velocity is constant
any time the valve is open; the short time duration between
open/close cycles produces the effect of contiuous
air delivered to the occupied space. They are rated for
24V (18-30VAC) operation; one (1) PAP-1 Plug & Play
Cable is included per air valve. Optional extended high
performance air valves are available (specify on order).
Optional duct connections are available in multiple
sizes and configurations. Ducted air flow capacity is
derived from the source; output is dependent on ducting
arrangement and fan capability.
The linear grille is available as extruded aluminum or
stainless steel, in a variety of sizes and configurations.
Ten (10) standard colors are available; custom colors and
finishes can be provided to match architectural design
(specify on order).

AirFixture ©2020 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V200131 1
DATA SHEET

Underfloor Air Distribution Linear Terminal


MODEL: CLEMIT
UNIT DETAIL:

1. Linear grille
(optional extruded aluminum or
stainless steel; specify on order)
2. Controls housing
3. Disconnect switch
2 3 4 5 4. Thermistor / thermal cutout
5. Sheathed electric heating element
6. 20 guage (1mm) galvanized
steel casing, pre-painted black
7. 3/4" (19mm) support flanges
(optional; specify on order)
8. Plug & play control cable
molex connection
8 9 10 6 11 7
9. Line power connection clamp
10. Duct connections
(optional; specify on order)
11. VAV air valves
(optional; specify on order)
12. Support pedestals / brackets on
nominal 36” (914mm) centers
(optional; specify on order)
L

12

L STANDARD LENGTH OPTIONS


in 24 36 48 60 72 84 96 108 120
H mm 610 914 1219 1524 1829 2134 2438 2743 3048

W STANDARD WIDTH OPTIONS H STANDARD HEIGHT OPTIONS


in 6 8 10 12 in 6 8 10 12
W mm 152 203 254 305 mm 152 203 254 305

ALL DIMENSIONS NOMINAL ± 0.1" (2.5mm)

AirFixture ©2020 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V200131 2
DATA SHEET

Underfloor Air Distribution Linear Terminal


MODEL: CLEMIT
FEATURES:
• 20 Gauge (1mm) galvanized steel terminal housing, • Modular Plug & Play power and control connections
pre-painted flat black • Sheathed electric heating element (0.5–2.0kW
• Optional terminal dimensions available (specify on order) standard, based on terminal / element length)
• Multiple grille configurations available • Single-point power connection for assembly
- Extruded aluminum / stainless steel (304 / 316 Series) • 40VA control transformer (100VA optional)
- Ten (10) standard colors; additional colors and finishes
• Low temperature finned heating elements
available at architect’s choice (specify on order)
• ETL listed, fully certified to UL standards
• Optional support pedestals / brackets (brackets factory
mounted; pedestals furnished loose for field installation) • “Heating-Only” option available
• Optional 3/4" (19mm) support flanges • Meets all NEC requirements
• Optional air valves (maximum size / number of air valves • Includes NEMA-1 enclosure
based on unit length)
• Main supply fusing
- DC synchronized magnetic motor
- Factory programmed multi-function circuit board
for varying control strategies
- Modular Plug & Play power and control connections
• Optional duct connections (size, shape, quantity)

SPECIFICATIONS:
Application: Underfloor Heating / Cooling | Raised Access Floor Systems
Terminal Dimensions: Specify on Order
Terminal Construction: Galvanized Steel | 20 Gauge (1mm) | Pre-Painted Black
Grille Configuration: Extruded Aluminum | 304 / 316 Series Stainless Steel (Specify On Order)
Heating Capacity: 0.5–2.0kW
Standard Capacity: 13" (330mm) Standard air Valve | 150 cfm @ 0.05 in. w.c. (255 m3/hr @ 12.5 Pa)
Air Flow (Nominal) OPTIONAL: 2 Air Valves = 300 cfm (510 m3/hr) | Minimum Trough Size: 4' (1.2m)
3 Air Valves = 450 cfm (765 m3/hr) | Minimum Trough Size: 6' (1.8m)
4 Air Valves = 600 cfm (1020 m3/hr) | Minimum Trough Size: 7' (2.1m)
5 Air Valves = 750 cfm (1275 m3/hr) | Minimum Trough Size: 8' (2.4m)
High Capacity: 22" (559mm) Extended Air Valve | 300 cfm @ 0.05 in. w.c. (510 m3/hr @ 12.5 Pa)
Air Flow (Nominal) OPTIONAL: 2 Air Valves = 600 cfm (1020 m3/hr) | Minimum Trough Size: 6' (1.8m)
3 Air Valves = 900 cfm (1530 m3/hr) | Minimum Trough Size: 8' (2.4m)
4 Air Valves = 1200 cfm (2040 m3/hr) | Minimum Trough Size: 10' (3.0m)

AirFixture ©2020 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V200131 3
DATA SHEET

Underfloor Air Distribution Linear Terminal


MODEL: CLEMIT
ELECTRICAL PERFORMANCE:
1. 120V (120/1/60) | 277V (277/1/60)
• Single Phase units require 3 conductors: Line / Neutral / Ground
2. 240V (240/1/60)
• Single Phase units require 3 conductors: Line1 / Line2 / Ground
3. 208V (208/1/60)
• Single Phase 208V requires 4 conductors: Line1 / Line2 / Neutral / Ground
Additional Voltages / 50Hz capabilities available on request.

PRODUCT PRIMARY MAXIMUM HEAT OUTPUT


HEATER AMPS MCA MOP
DESCRIPTION VOLTAGE / PH KW
005 120 1 0.5 4.2 5.2 10
010 120 1 1.0 8.3 10.4 15
12
015 120 1 1.5 12.5 15.6 20
020 120 1 2.0 16.7 20.8 25
005 208 1 0.5 2.4 3.0 5
010 208 1 1.0 4.8 6.0 10
20
015 208 1 1.5 7.2 9.0 10
020 208 1 2.0 9.6 12.0 15
CLEMIT
005 240 1 0.5 2.1 2.6 5
010 240 1 1.0 4.2 5.2 10
24
015 240 1 1.5 6.3 7.8 10
020 240 1 2.0 8.3 10.4 15
005 277 1 0.5 1.8 2.3 5
010 277 1 1.0 3.6 4.5 5
27
015 277 1 1.5 5.4 6.8 10
020 277 1 2.0 7.2 9.0 10

AirFixture ©2020 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V200131 4
DATA SHEET

Underfloor Air Distribution Linear Terminal


MODEL: CLEMIT
C LE - 0 6 - 02 4 - 0 6 - 0 0 - 12 - 0 5 - 1 V S

PRODUCT OPENING DIMENSION


DESCRIPTION Air Valve (Length)
Continuous S = Standard Capacity (13")
Linear L = High Capacity (22")
Electric Heating
Duct Connection
(Ellipsoid / Round Diameter)
(Rectangle Height)
TERMINAL WIDTH A = 4"
06 = 6" (152mm) B = 5"
08 = 8" (203mm) C = 6"
10 = 10" (254mm) D = 7"
12 = 12" (305mm) E = 8"
F = 9"
G = 10"
TERMINAL LENGTH H = 11"
024 = 24" (610mm) I = 12"
036 = 36" (914mm)
048 = 48" (1219mm)
060 = 60" (1524mm) OPENING DESCRIPTION
072 = 72" (1829mm) V = VAV Air Valve
084 = 84" (2134mm) Duct Connection
096 = 96" (2438mm) L = Ellipsoid
108 = 108" (2743mm) R = Round
120 = 120" (3048mm)
Duct Connection
(Rectangle Width)
A = 4"
TERMINAL HEIGHT B = 5"
06 = 6" (152mm) C = 6"
08 = 8" (203mm) D = 7"
10 = 10" (254mm) E = 8"
12 = 12" (305mm) F = 9"
G = 10"
H = 11"
TERMINAL FLANGE CONFIGURATION I = 12"
00 = Fully Flangeless
20 = Two (2) Flanges (Sides Only)
3L = Three (3) Flanges (Sides + Left End) AIR FLOW OPENINGS
3R = Three (3) Flanges (Sides + Right End) 1 = One (1) Opening
40 = Four (4) Flanges (All Sides + Ends) 2 = Two (2) Openings
3 = Three (3) Openings
4 = Four (4) Openings
ELECTRICAL VOLTAGE 5 = Five (5) Openings
12 = 120V (120/1/60)
20 = 208V (208/1/60)
24 = 240V (240/1/60) HEATING OPTIONS
27 = 277V (277/1/60) 05 = 0.5 kW Electric Element
10 = 1.0 kW Electric Element
15 = 1.5 kW Electric Element
20 = 2.0 kW Electric Element

AirFixture ©2020 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V200131 5
DATA SHEET

In-Floor Chilled Beam


MODEL: AIFCB
DesCrIptIon:
AIFCB (In-Floor Chilled Beam) 2-Pipe
or 4-Pipe models are designed to create
an efficient and simple solution to meet
perimeter cooling needs. Supply and
return water connections are located on
opposite ends of the trough. Chilled water
can be passed through these connections
based on the building demands and the
facility operators control. By controlling
water valves and time modulating the
air valves in response to a thermostat
located in the space, one can meet the
perimeter demands of any season.
The air valve(s) uses time modulation to
vary total air delivered to the conditioned
space. Air velocity is constant any time
the valve(s) is open; the short time
duration between air pulses results in
the sensation of continuous air delivered
with consistent flow. The air valve(s) is
rated for 24 volt (18-30VAC) operation ALL DIMENSIONS NOMINAL +/- 0.1" (2.5mm)
and comes with one (1) PAP-1 Plug &
Play cable. One (1) additional connection X (in) 48 60 72 84 96 108 120

cable is included for dual air valve X (mm) 1219 1524 1829 2134 2438 2743 3048

configurations. Y (in) 8 10 12 Z (in) 8 10 12


Z
All AIFCB’s are available in variable Y (mm) 203 254 305 Z (mm) 203 254 305
1ӯ (25mm)
dimensions, in both typical density (TD) WATER S/R CONNECTIONS XG X - 0.375” (9.5mm)
and high density (HD) designs. These YG Y - 0.375” (9.5mm)
options reflect the ability to achieve a Y
greater capacity by adding an additional
air valve to create an HD unit. XG

The linear grille is extruded aluminum,


and is available in ten (10) standard YG
colors. Customized colors and finishes
are available to match architectural
design (specify on order).

1ӯ (25mm) WATER S/R CONNECTIONS

AirFixture ©2019 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V190515 1
DATA SHEET

In-Floor Chilled Beam


MODEL: AIFCB
MoDes oF operAtIon | 2-pIpe:

COOLING MODE
The thermostat detects a cooling condition and the aquastat
detects chilled water: the control box will begin to time modulate
the air valves and open the water valve. Chilled water flows through
the coil, and air passes through the unit in a time modulation of
six second full open bursts. Once the thermostat detects that the
occupied space has reached set point, the system will return to
suspend mode, closing the air and water valves awaiting further
system demands.

HEATING MODE
The thermostat detects a heating condition and the aquastat
detects hot water: the control box will begin to time modulate the
water valve while the air valve remains closed. As hot water flows
through the coil, air falls into the chilled beam where it is heated
and convects out into the space. If additional heating is required
to reach setpoint, the air valve will also time modulate. Once the
thermostat detects that the occupied space has reached set point,
the system will return to suspend mode, closing the air and water
valves, awaiting further system demands.

SHOULDER SEASON
The thermostat detects a cooling condition and the aquastat
detects hot water: the control box will time modulate the air
valves while the water valve remains closed. Once the thermostat
reaches set point, the air valves will close and the system will
return to suspend mode.
The thermostat detects a heating condition and the aquastat
detects chilled water: the control box will instruct the system to
remain in suspend mode, awaiting further system demands.

AirFixture ©2019 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V190515 2
DATA SHEET

In-Floor Chilled Beam


MODEL: AIFCB
MoDes oF operAtIon | 2-pIpe / eLeCtrIC HeAt:

COOLING MODE
The thermostat detects a cooling condition and the aquastat
detects chilled water: the control box will begin to time modulate
the air valves and open the water valve. Chilled water flows through
the coil, and air passes through the unit in a time modulation of
six second full open bursts. Once the thermostat detects that the
occupied space has reached set point, the system will return to
suspend mode, closing the air and water valves awaiting further
system demands.

HEATING MODE
The thermostat detects a heating condition: the control box will
begin to time modulate the electric heater while the air valve
remains closed. As the electric coil heats up, air falls into the
chilled beam where it is heated and convects out into the space.
If additional heating is required to reach setpoint, the air valve
will also time modulate. Once the thermostat detects that the
occupied space has reached set point, the system will return
to suspend mode, closing the air and de-energizing the heater,
awaiting further system demands.

AirFixture ©2019 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V190515 3
DATA SHEET

In-Floor Chilled Beam


MODEL: AIFCB
MoDes oF operAtIon | 4-pIpe:

COOLING MODE
The thermostat detects a cooling condition: the control box will
begin to time modulate the air valves and open the chilled water
valve. Chilled water flows through the coil, and air passes through
the unit in a time modulation of six second full open bursts. Once
the thermostat detects that the occupied space has reached set
point, the system will return to suspend mode, closing the air and
chilled water valves awaiting further system demands.

HEATING MODE
The thermostat detects a heating condition and the aquastat
detects hot water: the control box will begin to time modulate the
hot water valve while the air valve remains closed. As hot water
flows through the coil, air falls into the chilled beam where it is
heated and convects out into the space. If additional heating is
required to reach setpoint, the air valve will also time modulate.
Once the thermostat detects that the occupied space has reached
set point, the system will return to suspend mode, closing the air
and hot water valves, awaiting further system demands.

AirFixture ©2019 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V190515 4
DATA SHEET

In-Floor Chilled Beam


MODEL: AIFCB
COOLING CAPACITY RANGE
900

800

700 )
irflow
e (H igh A
2-Pip
CAPACITY (btu/hr-lf)

HIGH AIRFLOW BEAMS


ow)
600
(Hig h Airfl
4-Pipe

500

STANDARD BEAMS
400
)
tandard
2-Pipe (S
300 tandard)
4-Pipe (S

200
58 56 54 52 50 48 46 44
COLD WATER SUPPLY TEMPERATURE (°F)

HEATING CAPACITY RANGE


2,400
w)
A irflo
2,200 (H igh
ipe
2-P
2,000

1,800
HIGH AIRFLOW BEAMS

)
CAPACITY (btu/hr-lf)

rflow
1,600 High Ai )
ipe ( ndard
4-P e (Sta
1,400 2-Pip
STANDARD BEAMS

1,200 ard)
(Stand
4-Pipe
1,000
2-Pipe (Electric)
800

600

400
110 120 130 140 150 160 170 180
HOT WATER SUPPLY TEMPERATURE (°F)

1. Standard ratings based on 19 cfm/lf @ 0.05" H2O Static Pressure, 2.0 gpm, 66°F db Inlet Air @ 50% RH, and 72°F db room
2. High airflow ratings based on 38 cfm/lf @ 0.05" H2O Static Pressure, 2.0 gpm, 66°F db Inlet Air @ 50% RH, and 72°F db room
3. Electric heat ratings based on 1/4 kW per linear foot

AirFixture ©2019 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V190515 5
DATA SHEET

In-Floor Chilled Beam


MODEL: AIFCB
seQUenCe oF operAtIon:
COOLING MODE | The thermostat detects a cooling condition: the air valve(s) shall duty cycle open allowing cold plenum
air into space. If additional cooling is required, the air valve will continue to time modulate open and chilled water valve shall
open (modulate open) allowing chilled water to flow through coil. Once the thermostat detects that the occupied space has
reached set point, the system will return to standby mode, closing the air and chilled water valves, awaiting further system
demands.
HEATING MODE | The thermostat detects a heating condition: heating hot water valve shall open (modulate open) while
the air valve remains closed. As hot water flows through the coil, room air is induced into the chilled beam where it is heated
and convects out into the space. If additional heating is required, the air valve will time modulate open increasing airflow
across coil. Once the thermostat detects that the occupied space has reached set point, the system will return to standby
mode, closing the air and hot water valves, awaiting further system demands.

speCIFICAtIons:
Application: Underfloor Heating / Cooling | Raised Access Floors 10.5" (267mm) +
Trough Dimensions: Specify on Order
Trough Construction: Galvanized Steel | 20 Gauge (1mm) | Pre-Painted Black
Grille Dimensions: Specify on Order
Grille Rating: Extruded Aluminum | Conforms to NFPA 90a | 1250 lbs. (567 Kg) Load Strength
Grille Configuration: Refer to Data Sheet: LGC (Linear Grille Configuration)
Supply Air Pressure: 0.02–0.1 in. w.c. (5–25 Pa)
Air Flow Capacity: Typical Density (TD): 150 cfm @ 0.05 in. w.c. (255 m3/hr @ 12.5 Pa)
Standard Air Valve High Density (HD): 300 cfm @ 0.05 in. w.c. (510 m3/hr @ 12.5 Pa)
(Nominal)

Cooling Capacity: 2P: 320 btu/hr @ EWT 52°F (93.8 watts/hr @ EWT 11°C)
(Nominal) 2P-HD: 610 btu/hr @ EWT 52°F (178.8 watts/hr @ EWT 11°C)
4P: 290 btu/hr @ EWT 52°F (85.0 watts/hr @ EWT 11°C)
4P-HD: 535 btu/hr @ EWT 52°F (156.8 watts/hr @ EWT 11°C)
Heating Capacity: 2P: 1050 btu/hr @ EWT 140°F (307.7 watts/hr @ EWT 60°C)
(Nominal) 2PE: 850 btu/hr @ EWT 140°F (249.1 watts/hr @ EWT 60°C)
2P-HD: 1950 btu/hr @ EWT 140°F (571.5 watts/hr @ EWT 60°C)
4P: 825 btu/hr @ EWT 140°F (241.8 watts/hr @ EWT 60°C)
4P-HD: 1375 btu/hr @ EWT 140°F (403.0 watts/hr @ EWT 60°C

AirFixture ©2019 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V190515 6
DATA SHEET

In-Floor Chilled Beam


MODEL: AIFCB
A IFC B - 0 8 - 0 4 8 - 0 8 - 0 0 - 2 p - 4 r - tD

PRODUCT AIR FLOW DESCRIPTION


DESCRIPTION TD = Typical Density
AirFixture In Floor (One (1) Air Valve)
Chilled Beam HD = High Density
(Two (2) Air Valves)

TROUGH WIDTH
08 = 8" (203mm) HyDRONIC COIL OPTIONS
10 = 10" (254mm) 4R = Four (4) Row Hydronic Fin Pack
12 = 12" (305mm) 5R = Five (5) Row Hydronic Fin Pack

TROUGH LENGTH PIPE CONFIGURATION


048 = 48" (1219mm) 2P = Two (2) Pipe
060 = 60" (1524mm) 4P = Four (4) Pipe
072 = 72" (1829mm)
084 = 84" (2134mm)
096 = 96" (2438mm)
108 = 108" (2743mm) LINEAR GRILLE CONFIGURATION
120 = 120" (3048mm) 00 = No Flanges
20 = Two (2) Flanges (Sides Only)
3L = Three (3) Flanges (Sides + Left End)
3R = Three (3) Flanges (Sides + Right End)
TROUGH HEIGHT 40 = Four (4) Flanges (All Sides + Ends)
08 = 8" (203mm)
10 = 10" (254mm)
12 = 12" (305mm)

AirFixture ©2019 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V190515 7
CONFIGURATION OPTIONS AIR SUPPLY / RETURN OPTIONS MOUNTING OPTIONS LINEAR GRILLE OPTIONS

15° INWARD
UFAD AIRWAY (RECOMMENDED)
COOLING HEATING ONLY AIR SEAL
WALL ANGLE
+ PEDESTALS
0° HIGH THROW
AIRWAY (NO LOAD ON WALL)
COOLING +
HOT WATER
HEATING AIR VALVES
15° + 0°
(MODULATED /
TIME MODULATED)
COMBINATION
AIRWAY
COOLING +
ELECTRIC FLANGELESS
HEATING GASKET
AIR VALVES + PEDESTALS
AIRWAY + (FRONT + BOTTOM
MOUNTING) 4-SIDED
CHILLED WATER
FLANGE
COOLING / HOT
WATER HEATING
2-SIDED
DUCTED FLANGE
AIRWAY + (ROUND / (CONTINUOUS)
HEAT / COOL ELIPSOID /
FAN BOOST RECTANGULAR) LOW HEIGHT
3-SIDED
(SCREW FOOT)
FLANGE
AIRWAY + (LEFT END)
CHILLED WATER
COOLING +
DUCTED + • Aluminum
ELECTRIC MATERIALS
AIR VALVE • Stainless Steel
HEATING

• Annodized
HANGING FROM FINISHES
ADD • Paint
PIPE CHASE RAISED FLOOR (ALUMINUM)
• Mill Finish
DUCTED (NOT
SUPPLY RECOMMENDED)
& RETURN CUSTOM SIZES AVAILABLE FOR
WIDE GRILLE TROUGHS AND LINEAR GRILLES
(LOW-FLOW
FOR Ve:1.2)

NARROW LINEAR
GRILLE
(ARCHITECTURAL TROUGH
AESTHETICS)
GUIDE
DATA SHEET

Underfloor Diffuser Grilles


MODEL: Standard Color Chart
AirFixture is pleased to offer the following standard color options for underfloor diffuser grilles. All grilles are electrostatically
coated with baked-on powder coating for the finest finish in the industry. The results of this process are not only aesthetically
unmatched, but will also enhance the grille’s ability to stand up to the harshest of applications.

STANDARD COLORS ANTIQUE COLORS

Putty RAL 9002 Antique Gray 09/90170

Beige RAL 1019 Silver Hammertone 09/90250

Dark Brown RAL 8014 Antique Silver 09/90190

Gray RAL 7012 Antique Copper 09/90180

Black RAL 9011 Antique Gold 09/90200

NOTE: Colors shown are reproductions intended to approximate actual colors as closely as possible.

AirFixture ©2019 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V190122 1
DATA SHEET

Underfloor Diffuser Grilles


MODEL: RAL Color Chart
AirFixture is pleased to offer
the following special order RAL
(Rutherford Appleton Laboratory)
color options for underfloor
diffuser grilles. All grilles are
electrostatically coated with
baked-on powered coating for
the best appearing finish in the
industry. The finish will enhance
the unit’s ability to stand up to the
harshness of any application.

NOTE: Colors shown are reproductions intended to approximate actual colors as closely as possible.

AirFixture ©2019 AirFixture, LLC 51 Kansas Avenue | Kansas City, KS 66105 | P: 913.312.1100 | F: 913.312.1105 | www.airfixture.com
V190402 1