Generator set data sheet

Model: C3500 D5e


Frequency: 50 Hz
Fuel type: Diesel
kVA rating: 3125 Data Center Continuous (DCC)
Emissions level: 2g TA Luft

Fuel consumption kVA (kW)


Ratings 3125 (2500)
1
Ratings without fan 3220 (2576)
Load 1/4 1/2 3/4 Full
US gph 51 89 127 165
L/hr 193 337 481 625
1
Ratings for reference with the optional remote radiator cooling configuration. See note 1 under “Alternator data” section.

Engine
Engine model QSK95-G5
Configuration Cast iron, Vee, 16 cylinder
Aspiration Turbocharged and after-cooled
Gross engine power output, kWm (bhp) 2665 (3572)
BMEP at set rated load, kPa (psi) 2241 (325)
Bore, mm (in) 190.0 (7.48)
Stroke, mm (in) 210.1 (8.27)
Rated speed, rpm 1500
Piston speed, m/s (ft/min) 10.5 (2067)
Compression ratio 15.5:1
Lube oil capacity, L (qt) 647 (684)
Overspeed limit, rpm 2070
Regenerative power, kW 230

Fuel flow
Maximum fuel flow, L/hr 1445.9 (382)
Maximum fuel inlet restriction with clean filter, kPa (in Hg) 13.5 (4)
Maximum fuel return line restriction, kPa (in Hg) 34 (10)
Maximum fuel inlet temperature, °C (°F) 71.1 (160)
Maximum fuel outlet temperature, °C (°F) 92.2 (198)

Air
3
Combustion air, m /min (scfm) 241 (8500)
Maximum air cleaner restriction with clean filter, mm H2O 457 (18)
(in H2O)
3
Alternator cooling air, m /min (cfm) 240 (8476)

power.cummins.com
©2017 Cummins Inc. | NAD-5830-DC-EN (10/17)
Exhaust
3
Exhaust flow at rated load, m /min (cfm) 526 (18570)
Exhaust temperature at set rated load, °C (°F) 392 (737)
Maximum back pressure, kPa (in H2O) 7 (28)

Standard set-mounted radiator cooling


Ambient design, °C (°F) 45 (113)
Fan load, kW m (HP) 78 (105)
Coolant capacity (with radiator), L (US gal) 1120 (296)
3
Cooling system air flow, m /min (scfm) 3135 (110700)
Maximum cooling air flow static restriction, kPa (in H2O) 0.12 (0.5)

Optional set-mounted radiator cooling


Ambient design, °C (°F) 55 (131)
Fan load, kW m (HP) 78 (105)
Coolant capacity (with radiator), L (US gal) 1120 (296)
3
Cooling system air flow, m /min (scfm) 3135 (110700)
Maximum cooling air flow static restriction, kPa (in H2O) 0.12 (0.5)

Optional remote radiator cooling


Engine coolant capacity, L (US gal) 379 (100)
Max flow rate at max friction head, jacket water circuit, 2559 (676)
L/min (US gal/min)
Max flow rate at max friction head, aftercooler circuit, 538 (142)
L/min (US gal/min)
Heat rejected, jacket water circuit, MJ/min (Btu/min) 69.70 (66060)
Heat rejected, aftercooler circuit, MJ/min (Btu/min) 16.90 (16040)
Heat rejected, fuel circuit, MJ/min (Btu/min) 0.21 (199)
Total heat radiated to room, MJ/min (Btu/min) 20.20 (19150)
Maximum friction head, jacket water circuit, kPa (psi) 59 (8.5)
Maximum friction head, aftercooler circuit, kPa (psi) 59 (8.5)
Maximum static head above engine crank centerline, 18 (60)
jacket water circuit, m (ft)
Maximum static head above engine crank centerline, 18 (60)
aftercooler circuit, m (ft)
Maximum jacket water outlet temp, °C (°F) 104.4 (220)
Maximum aftercooler inlet temp, °C (°F) 71.1 (160)
Maximum aftercooler inlet temp at 25 °C (77 °F) ambient, 46.1 (115)
°C (°F)
Note: For non-standard remote installations contact your local Cummins representative.

Weights
Unit dry weight kgs (lbs) 29500 (65100)
Unit wet weight kgs (lbs) 31200 (68771)
Note: Weights represent a set with standard features and alternator frame P80X. See outline drawing for weights of other configurations.

Derating factors
Full genset power available up to 4000 m (13123 ft) at ambient temperatures up to 40 °C (104 °F) and 3333 m (10935 ft) at
ambient temperatures up to 50 °C (122 °F). Above these conditions, derate at 1.7% per 305 m (1000 ft) and 4% per 10 °C
(18 °F).

Ratings definitions
Data Center Continuous (DCC): Applicable for supplying power continuously to a constant or varying electrical load for
unlimited hours in a data center application.

power.cummins.com
©2017 Cummins Inc. | NAD-5830-DC-EN (10/17)
Alternator data1
Temp Max surge Feature
2 3
Voltage Connection rise ºC Duty kVA Winding No. Alternator code
380 Wye, 3-phase 105 DCC 9956 12 ADS-531 BB32-2
380 Wye, 3-phase 125 DCC 9956 12 ADS-531 BB33-2
380 Wye, 3-phase 150 DCC 9956 12 ADS-531 BB34-2
400 Wye, 3-phase 80 DCC 11146 12 ADS-532 BB35-2
400 Wye, 3-phase 105 DCC 9954 12 ADS-531 BB36-2
400 Wye, 3-phase 125 DCC 9954 12 ADS-531 BB37-2
400 Wye, 3-phase 150 DCC 9954 12 ADS-531 BB38-2
415 Wye, 3-phase 80 DCC 11146 12 ADS-532 BB39-2
415 Wye, 3-phase 105 DCC 10132 12 ADS-531 BB40-2
415 Wye, 3-phase 125 DCC 10132 12 ADS-531 BB41-2
415 Wye, 3-phase 150 DCC 10132 12 ADS-531 BB42-2
440 Wye, 3-phase 105 DCC 11025 12 ADS-532 BB43-2
440 Wye, 3-phase 125 DCC 9853 12 ADS-531 BB44-2
440 Wye, 3-phase 150 DCC 9853 12 ADS-531 BB45-2
690 Wye, 3-phase 105 DCC 9960 65 ADS-531 BB46-2
690 Wye, 3-phase 125 DCC 9960 65 ADS-531 BB47-2
690 Wye, 3-phase 150 DCC 9960 65 ADS-531 BB48-2
3300 Wye, 3-phase 80 DCC 10845 51 ADS-587 BB49-2
3300 Wye, 3-phase 105 DCC 9481 51 ADS-545 BB50-2
3300 Wye, 3-phase 125 DCC 7040 51 ADS-520 BB51-2
3300 Wye, 3-phase 150 DCC 7040 51 ADS-520 BB52-2
6000 Wye, 3-phase 80 DCC 10463 71 ADS-534 BB53-2
6000 Wye, 3-phase 105 DCC 8866 71 ADS-533 BB54-2
6000 Wye, 3-phase 125 DCC 8866 71 ADS-533 BB55-2
6000 Wye, 3-phase 150 DCC 8866 71 ADS-533 BB56-2
6300 Wye, 3-phase 80 DCC 10727 61 ADS-534 BB57-2
6300 Wye, 3-phase 105 DCC 9440 61 ADS-533 BB58-2
6300 Wye, 3-phase 125 DCC 9440 61 ADS-533 BB59-2
6300 Wye, 3-phase 150 DCC 9440 61 ADS-533 BB60-2
6600 Wye, 3-phase 80 DCC 10656 61 ADS-534 BB82-2
6600 Wye, 3-phase 105 DCC 9378 61 ADS-533 BB61-2
6600 Wye, 3-phase 125 DCC 9378 61 ADS-533 BB62-2
6600 Wye, 3-phase 150 DCC 9378 61 ADS-533 BB63-2
10k Wye, 3-phase 80 DCC 10427 81 ADS-534 BB64-2
10k Wye, 3-phase 105 DCC 9125 81 ADS-533 BB65-2
10k Wye, 3-phase 125 DCC 9125 81 ADS-533 BB66-2
10k Wye, 3-phase 150 DCC 9125 81 ADS-533 BB67-2
10.5k Wye, 3-phase 80 DCC 12784 8021 ADS-588 BB68-2
10.5k Wye, 3-phase 105 DCC 10665 83 ADS-534 BB69-2
10.5k Wye, 3-phase 125 DCC 9333 83 ADS-533 BB70-2
10.5k Wye, 3-phase 150 DCC 9333 83 ADS-533 BB71-2
11k Wye, 3-phase 80 DCC 10613 83 ADS-534 BB72-2
11k Wye, 3-phase 105 DCC 9288 83 ADS-533 BB73-2
11k Wye, 3-phase 125 DCC 9288 83 ADS-533 BB74-2
11k Wye, 3-phase 150 DCC 9288 83 ADS-533 BB81-2

Notes:
1
Alternator data is configured for a set with ratings including engine cooling fan losses and standard features at 40 °C ambient temperature. For non-standard
configurations, including remote radiator applications, check appropriate alternator data sheets or contact your local Cummins representative.
2
Standby (S), Prime (P) and Continuous ratings (C).
3
Maximum rated starting kVA that results in a minimum of 90% of rated sustained voltage during starting.

Warning: Back feed to a utility system can cause electrocution and/or property damage. Do not connect to any building’s electrical system
except through an approved device or after building main switch is open.

For more information contact your local Cummins distributor


or visit power.cummins.com

©2017 Cummins Inc. All rights reserved. Cummins is a registered trademark of Cummins Inc. PowerCommand, AmpSentry, InPower and “Our energy working for you.” are trademarks of