You are on page 1of 10

*w*

ri 'rii, .li rttr' ll


BRB CABLE INDUSTRIES LIMITEI)
BSCIC INDUSTRIAL ESTATE, KUSHTIA-7OOO BANGLADESH
ffi
CABLE DETAILS :lC X 500 SQMM 33 KV ( Maximum-36 KV)
:BRB CABLE INDUSTRIES Ltd; BSCIC INDUSTRIAL ESTATE, KUSHTIA-
SUPPLIER
TOOO BANGLADESH
PURCHASER : BANGLADESH RURAL ELECTRIFICATION BOARD
CONTRACT REF. : BRE B/ U RE D S-G-22-00L/ 47 / 20L9 -2020
LOT NO" : UREDS-G-22-001
ITEM NO : F-8
CONTRACTUAL QUANTITY :230 KM {g{O
INSPECTED qUANTITY : 113.5 KM (Second and=fiflal consighnment)
DATE OF INSPECTION ; 07 10612020, L6/0612o & L7 loilzo
PLACE OF INSPECTION : Manufacturer's Factory premises
TESTED AS PER STANDARD : IEC-60502-2
SL No. Description of Test Unit Specified Obtained Remarks
1 Min No.of wire in each conductor No. 61 wires 61

2 Approx Conductor diameter mm 26.30 App. 26.4

Thickness of ISC mm 0.80 App. o.92


3 Thickness of lnsulation XLPE mm 9.0 Nom.. 9.25
Thickness of OSC mm 1.0 App. L,L2
Hot set Test @ 200oC
4 Maximum elongation under load % 175 Max. 85.5
Maximum permanent elongation % 15 Max. 1.15

5 Tensile Strength of XLPE before ageing N/mmz 12.5 Min. 32.5L

6 Elongation at break of XLPE before ageing % 200 Min. 603.85

7 Tensile Strength of XLPE after ageing N/mm2 12.5 Min. 32.46

8 Elongation at break of XLPE after ageing % 200 Min. 6LL.25

9 Variation in Tensile Strength of XLPE % t 25 max -0.153


Complied
10 Variation in Elongation of XLPE o/o
t 25 max t.22
LL Cu wire screen No. & Diameter No./mm 72xL.76 72 x L.768

L2 Thickness of lnner Sheath (MDPE) mm 1.50 Nom. 1.8

L3 Al Alloy wire Armour No. & Diameter mm 64 x2.50 64x2.5L2


L4 Thickness of Outer sheath (MDPE) mm 3.0 Nom 3.40

15 Tensile Strength of MDPE Sheath before ageing N/mm2 12.5 Min 27.75

16 Elongation at break of MDPE Sheath before agei % 300 Min. 728.20

L7 Tensile Strength of MDPE sheath after ageing N/mm2 24.93

18 Elongation at break of MDPE sheath after ageing % 300 Min. 7L7

19 Approx. Overall diameter of cable mm 66.0 Min. 71.50

e*q-6,94 ffi#
20 Conductor Resistance at 20oC o/km 0.0355 Max. 0.0362

2L Capacitance of Cable pflKm 0.252

22 lR at ambient Temp,with 5 Kv Voltage GO 78.O

23 Partial Discharge Test at 1.73Uo kV pC 10 Max. 2.52 Complied

63.0
24 AC high Voltage test for 5 minutes KV Withstood
(Shall Withstand)

25 Cable Length Mtrs. 1000 1000


26 Cable Weight KglKm 9860

BRB CABLES BANGLADESH 18/30(35KV) 1CX500 SqMM


27 Embossing on Cable
BANGLADESH RURAL ELECTRIFICATION BOARD- 2O2O

Performed by : Witnessed by:


--fuYd
Sub anda I
t/ n ZPZO, \+ ^ D6'al'o
Md.Alamfir Hossain
DGM Q.C. Deputy Director (Tech)
BRB Cable lndustries Ltd I& T, BREB, DhaKa
BRB CABLE INDUSTRIES LIMITED
ffi
. ,, :gE
'p
:UMNd

BSCIC INDUSTRIAL ESTATE, KUSHTIA-7OOO BANGTADESH


TEST REPORT ON PRE-DELIVFRY TNSPECTION Drum No. 291
CABLE DETAILS :lC X 500 SqMM 33 KV ( Maximum- 36 KV)
:BRB CABLE INDUSTRIES ttd; BSCIC INDUSTRIAL ESTATE, KUSHTIA'
SUPPLIER
TOOO BANGLADESH
PURCHASER : BANGLADESH RURAL ELECTRIFICATION BOARD

CONTRACT REF. : BREB/U REDs -G-22'O0t I 47 I 2OL9-2020

LOT NO. : UREDS-G-22-001


: F-8

tu
ITEM NO
CONTRACTUAL QUANTITY : 230 KM
INSPECTED QUANTITY : 113.5 KM (Second an4fiful consighnment)
DATE OF INSPECTION :07 10612020,16105120 & t7 lo5l2o
PLACE OF INSPECTION : Manufacturer's Factory premises
TESTED AS PER STANDARD : IEC-60502-2

SL No. Description of Test Unit Specified Obtained Remarks

1 Min No.of wire in each conductor No. 61 wires 61

2 Approx Conductor diameter mm 26.30 App. 26.3s

Thickness of lSC mm 0.80 App. 0.90


3 Thickness of lnsulation XLPE mm 9.0 Nom.. 9.15
Thickness of OSC mm 1.0 App. 1.15

4
m
Maximum elongation under load % 175 Max.
82.1
1.5
Maximum permanent elongation % 15 Max.

5 Tensile Strength of XLPE before ageing N/mm2 12.5 Min. 31.94

6 Elongation at break of XLPE before ageing o/o


200 Min. 648.50

7 Tensile Strength of XLPE after ageing N/mm2 12.5 Min. 34.13

8 Elongation at break of XLPE after ageing % 200 Min. 637.4

9 Variation in Tensile Strength of XLPE % t 25 max 5.85


Complied

10 Variation in Elongation of XLPE % + 25 max -1.7L

11 Cu wire screen No, & Diameter No./mm 72 x 7.76 72 x L.755

t2 Thickness of lnner Sheath (MDPE) mm 1.60 Nom. 1.75

13 Al Alloy wire Armour No. & Diameter mm 64 x 2.50 54 x 2.515

74 Thickness of Outer sheath (MDPE) mm 3.0 Nom 3.20

15 Tensile Strength of MDPE Sheath before ageing N/mm2 12.5 Min, 30.82

16 Elongation at break of MDPE Sheath before ageing % 300 Min. 716.L5

t7 Tensile Strength of MDPE sheath after ageing N./mm'z 29.88

o/ 300 Min.
18 Elongation at break of MDPE sheath after ageing /o 722.75

19 Approx. Overall diameter of cable mm 56.0 Min. 71.00

"-( ffi-c
20 Conductor Resistance at 20oC o/km 0.0366 Max. 0.0364

2L Capacitance of Cable pflKm o.26t

22 lR at ambient Temp.with 5 Kv Voltage GO 139

23 Partial Discharge Test at 1.73Uo kV pC 10 Max. 1.95

63.0 Complied
24 AC high Voltage test for 5 minutes KV Withstood
(Shall Withstand)

At 4Uo (72 Kv) lstratt


25 4 Hour high voltage test KV Withstood
withstand)

26 Cable Length Mtrs. 500 s00

27 Cable Weight Kg/Km 9890

BRB CABLES BANGLADESH 18/30(36KV) 1CX500 SQMM BANGLADESH


28 Embossing on Cable
RURAT ELECTRIFICATION BOARD. 2O2O

Performed by

ffi
: Witnessed by:
ar-l
r z.o z-o
aL-?)U
Subrata andal Md.AlamsirYf; in
DGM Q.C, Deputy Director (Tech)
BRB Cable lndustries Ltd I& T, BREB, Dhaka
{a ff i-

BRB CABLE INDUSTRIES LTD.


BSCIC lndustrial Estate, Kushtia
Packing List
To
The Project Director
UREDS; DCSD Project (Up-gradation of Rural Electricity
Distribution System; Dhaka, Chittagong & Sylhet Division)
Bangladesh Rural Electrification Board
Training Academy Building (6 th flooQ
Nikunja-2, Khilkhet, Dhaka- 1 229, Bang ladesh.

Size: 1C x 500 SQ MM 33 KV (Maximum-36Kv)


Type: XLPE-TR insulated, 1-core,Copper wire shielded underground cable.
Contract no. : B RE B/U R E DS -G-22-0A 1 H7 120 1 9-2020
Date: 03.1 1 .2019
Gross Weight
SL No. Drum No. Length (m) Net Weight (Kg) Remarks
(Ks)
176 176 1000
177 177 500
178 178 500
179 179 500
180 180 1000
181 181 1 000

182 182 1000


183 183 1000
184 184 1000
185 185 1 000

186 186 1 000

187 187 1000


188 188 1000
189 189 1 000

190 190 500


191 191 500
192 192 500
193 193 1 000

194 194 1002


2 mtr consumed
195 195 998
in lnspection
196 196 502
197 197 498
198 198 500
199 199 500
200 200 1000
201 201 1000
202 202 1 000

203 203 500


204 204 500
205 205 1000
206 206 1 000

207 207 1 000

208 208 1 000

209 209 1000


210 210 1000
211 211 1 000

212 212 1 000

213 213 1 000

214 214 1 000

21s 215 1 000

Total , 34000
I

Gross Weight
SL No. Drum No. Length (m) Net Weight (Kg) Remarks
(Kg)
216 216 500
217 217 500
218 218 500
219 219 500
220 220 1000
221 221 999
222 222 1 001
223 223 1 000
224 224 1000
225 225 500
226 226 500
227 227 500
228 228 500
229 229 1 000

230 230 500


231 231 1 000

232 232 1000


233 233 1 000

234 234 1 000

235 235 1 000

236 236 1 000

237 237 1 000

238 238 1000


239 239 500
240 240 500
241 241 500
242 242 500
243 243 500
244 244 1000
245 245 1000
246 246 500
247 247 1 000

248 248 500


249 249 500
250 250 500
251 251 '1000
252 252 500
253 253 500
254 254 500
255 255 500
Total 63000
Gross tlUeighl
SL No. Drum No. Length (m) Net Weight (Kg) Remarks
(Ks)
256 256 1000
257 257 1000
258 258 1000
259 259 500
260 260 500
261 261 1000
262 262 497
263 263 503
204 264 500
265 26s 1000
266 266 500
267 267 500
268 268 500
269 269 1000
274 274 1000
271 271 1000
272 272 500
273 273 500
274 274 500
275 275 1000
276 276 500
277 277 500
278 278 500
279 279 500
280 280 1000
281 281 1000
282 282 500
283 283 500
284 284 500
285 285 s00
286 286 500
287 287 500
288 288 500
289 289 500
290 290 500
291 291 500
292 292 500
293 293 500
294 294 500
295 295 500
Total 88500
a

Gross Weight
SL No Drum No Length (m) Net Weight (Kg) Remarks
(Ks)
296 296 500
297 297 500
298 298 500
299 299 500
300 300 500
301 301 500
302 302 sQ0
303 303 s00
304 304 500
305 305 500
306 306 500
307 307 500
308 308 500
309 309 500
310 310 500
311 311 500
312 312 500
313 313 500
314 314 500
315 315 500
316 316 500
317 317 500
318 318 500
319 319 500
320 320 500
321 321 500
322 322 500
323 323 500
324 324 s00
325 325 500
326 326 500
327 327 500
328 328 500
329 329 500
330 330 s00
331 331 500
332 332 500
333 333 50Q
334 334 500
335 335 500
Total
" J'"

Gross Weight
SL No. Drum No. Length (m) Net Weight (Kg) Remarks
(Ks)
336 336 500
337 337 500
338 338 500
339 339 500
340 340 500
341 341 500
342 342 500
343 343 500
344 344 500
345 345 500
Total 1 1 3500