You are on page 1of 6

BF800C - Display Codes / Command Codes

Revision: 10
Date: 16.04.2013
Source: dispcode_BF800C.h, dispcode_os.h, dispcode_SCU.h, dispcode_MCU.h Value = Display_Value * Scaling
Corresponding sw versions: >= 0.27/0.23

Control unit
Related to terminal
Display Code Description processing Related to device Scaling Unit Range Min. Range Max. Comment
(measuring point)
display code
555 DISP_SW_VERSION_NUMBER A34 A34 -- 1 1 -- --
556 DISP_BMSAZ_FIRMWARE_VERSION A34 A81 -- 1 1 2.17 --
557 DISP_DASA_FIRMWARE_VERSION A34 A80 -- 1 1 1.16 --
720 DISP_CURRENT_MACHINE_TYPE A34 A34 -- 1 1 7870 7879
900 DISP_IO_FAULT_CHECK_ENABLE A34 A34 -- 1 1 0 1 0 = Disabled, 1 = Enabled
901 DISP_ENGINE_RUNNING A34 A34 -- 1 1 0 1 0 = Engine running, 1 = Engine off
1001 DISP_BRAKE_OUTPUT_VOLTAGE A34 Y04 X35:45 1 V 0.0 28.0
1004 DISP_PROPEL_SENSOR_SLOPE_CURRENT A34 B56 X71:12 0.01 mA 370 20500
1005 DISP_PROPEL_SENSOR_SLOPE_VALUE_NORM A34 B56 -- 1 1 0 1000
1006 DISP_PROPEL_SENSOR_SLOPE_VALUE_PHYS A34 B56 -- 0.1 deg -300 300
1007 DISP_PROPEL_SENSOR_SLOPE_STATE A34 B56 -- 1 1 0 2 0 = Not initialized, 1 = Intialialized, 2 = Error
1010 DISP_PROPEL_POTI_SPEED_PRINCIPAL_VOLT A34 R07 X35:8 10 mV 60 750
1011 DISP_PROPEL_POTI_SPEED_PRINCIPAL_NORM A34 R07 -- 1 1 0 1000
1012 DISP_PROPEL_POTI_SPEED_REFERENCE_VOLT A34 R07 X35:9 10 mV 60 750
1013 DISP_PROPEL_POTI_SPEED_REFERENCE_NORM A34 R07 -- 1 1 0 1000
1020 DISP_PROPEL_SPEED_COMMAND_NORM A34 A34 -- 1 1 0 1000
1021 DISP_PROPEL_SPEED_COMMAND_PHYS A34 A34 -- 0.01 m/min 0 7500
1023 DISP_PROPEL_DIRECTION A34 A34 -- 1 1 0 3 0 =Forward, 1 = Neutral, 2 = Backward, 3 = Error
1028 DISP_PROPEL_SWITCH_MODE A34 S217 X35:37 1 1 1 100 1 = Work mode, 100 = Transport mode
1029 DISP_PROPEL_SWITCH_LEVER_DIRECTION A34 S221 X35:14, X35:15, X35:16 1 1 0 1111 1xxxx = Forward switch, x11x = Neutral switch, xxxx1 = Backward switch
1030 DISP_PROPEL_SWITCH_HYDRAULIC_GEAR A34 S220 X12:4 1 1 0 1 0 = Low gear (turtle), 1 = High gear (rabbit)
1032 DISP_PROPEL_SWITCH_STOP_BRAKE A34 S04 X35:40, X35:41 1 1 0 1 0 = No stop brake request, 1 = Stop brake request
1040 DISP_PROPEL_SWITCH_SPIN A34 S261 X35:36 1 1 0 1 0 = No spin request, 1 = Spin request
1041 DISP_PROPEL_CRAWLER_SPEED_SIMULTANEOUSLY A34 B109, B110 -- 0.01 m/min 00.00 99.99 LL.RR
1042 DISP_PROPEL_CRAWLER_SPEED_LEFT A34 B109 -- 0.01 m/min 0 9999
1043 DISP_PROPEL_CRAWLER_SPEED_RIGHT A34 B110 -- 0.01 m/min 0 9999
1044 DISP_PROPEL_CRAWLER_SPEED_CONTROLLER_ACTIVE A34 A34 -- 1 1 0 1 0 = Not active, 1 = Active
1050 DISP_HYDR_GEAR_LEFT_OUTPUT_VOLTAGE A34 Y197 X35:20 1 V 0.0 28.0
1051 DISP_HYDR_GEAR_RIGHT_OUTPUT_VOLTAGE A34 Y198 X35:21 1 V 0.0 28.0
1052 DISP_HYDR_GEAR_LEFT_OUTPUT_CURRENT A34 Y197 X35:20 1 mA 0 1200
1053 DISP_HYDR_GEAR_RIGHT_OUTPUT_CURRENT A34 Y198 X35:21 1 mA 0 1200
1060 DISP_PROPEL_MOVE_STATE A34 A34 -- 1 1 0 3 0 = StopBrake, 1 = Brake, 2 = Neutral, 3 = Run
1061 DISP_PROPEL_BRAKE_RELEASE_REQ A34 A34 -- 1 1 1 1 0 = No brake release request, 1 = Brake release request
1070 DISP_PROPEL_PUMP_LEFT_CURRENT_COMMAND_FWD A34 Y16 -- 1 mA 0 650
1071 DISP_PROPEL_PUMP_LEFT_CURRENT_FEEDBACK_FWD A34 Y16 X35:46 1 mA 40 650 The min. current might be equal to zero in case the supply voltage is below 25.6 V.
1072 DISP_PROPEL_PUMP_LEFT_CURRENT_MIN_FWD_PAR A34 Y16 -- 1 mA 170 220
1073 DISP_PROPEL_PUMP_LEFT_CURRENT_MAX_FWD_PAR A34 Y16 -- 1 mA 600 650
1075 DISP_PROPEL_PUMP_LEFT_CURRENT_COMMAND_BWD A34 Y17 -- 1 mA 0 670
1076 DISP_PROPEL_PUMP_LEFT_CURRENT_FEEDBACK_BWD A34 Y17 X35:47 1 mA 40 670 The min. current might be equal to zero in case the supply voltage is below 25.6 V.
1077 DISP_PROPEL_PUMP_LEFT_CURRENT_MIN_BWD_PAR A34 Y17 -- 1 mA 190 240
1078 DISP_PROPEL_PUMP_LEFT_CURRENT_MAX_BWD_PAR A34 Y17 -- 1 mA 620 670
1080 DISP_PROPEL_PUMP_RIGHT_CURRENT_COMMAND_FWD A34 Y72 -- 1 mA 0 650
1081 DISP_PROPEL_PUMP_RIGHT_CURRENT_FEEDBACK_FWD A34 Y72 X35:48 1 mA 40 650 The min. current might be equal to zero in case the supply voltage is below 25.6 V.
1082 DISP_PROPEL_PUMP_RIGHT_CURRENT_MIN_FWD_PAR A34 Y72 -- 1 mA 170 220
1083 DISP_PROPEL_PUMP_RIGHT_CURRENT_MAX_FWD_PAR A34 Y72 -- 1 mA 600 650
1085 DISP_PROPEL_PUMP_RIGHT_CURRENT_COMMAND_BWD A34 Y73 -- 1 mA 0 670
1086 DISP_PROPEL_PUMP_RIGHT_CURRENT_FEEDBACK_BWD A34 Y73 X35:49 1 mA 40 670 The min. current might be equal to zero in case the supply voltage is below 25.6 V.
1087 DISP_PROPEL_PUMP_RIGHT_CURRENT_MIN_BWD_PAR A34 Y73 -- 1 mA 190 240
1088 DISP_PROPEL_PUMP_RIGHT_CURRENT_MAX_BWD_PAR A34 Y73 -- 1 mA 620 670
2001 DISP_PROPEL_TRANSD_STEERING_PRINCIPAL_CURRENT A34 A45 X35:6 0.1 mA 37 2050 12mA +/- 0.2mA = Neutral, Left < 12 +/- 0.2mA, Right Left > 12 +/- 0.2mA
2002 DISP_PROPEL_TRANSD_STEERING_PRINCIPAL_POSITION_NORM A34 A45 -- 1 1 -1000 1000
2003 DISP_PROPEL_TRANSD_STEERING_REFERENCE_CURRENT A34 A45 X35:7 0.1 mA 37 2050 12mA +/- 0.2mA = Neutral, Left > 12 +/- 0.2mA, Right Left < 12 +/- 0.2mA
2004 DISP_PROPEL_TRANSD_STEERING_REFERENCE_POSITION_NORM A34 A45 -- 1 1 -1000 1000
2005 DISP_PROPEL_TRANSD_STEERING_STATE A34 A45 -- 1 1 0 2 0 = Not initialized, 1 = Intialialized, 2 = Error
2010 DISP_PROPEL_STEERING_REQUEST A34 A34 -- 1 1 0 2 0 = Left, 1 = Rgiht, 2 = Neutral
2011 DISP_PROPEL_STEERING_MODE A34 A34 -- 1 1 0 3 0 = IncreaseStay, 1 = IncreaseDecrease, 2 = IncreaseLimitedDecrease, 3 = Spin
3030 DISP_SCREED_CTRL_LCS_POTI_WORK_SPEED_U_VOLT A121 R100 X68:6 10 mV 70 700
3031 DISP_SCREED_CTRL_LCS_POTI_WORK_SPEED_U_NORM A121 R100 -- 1 1 0 1000
3032 DISP_SCREED_CTRL_LCS_POTI_STOP_SPEED_U_VOLT A121 R101 X68:7 10 mV 70 700
3033 DISP_SCREED_CTRL_LCS_POTI_STOP_SPEED_U_NORM A121 R101 -- 1 1 0 1000
3034 DISP_SCREED_CTRL_LCS_POTI_TIME_LOCK_SPEED_U_VOLT A121 R102 X68:8 10 mV 70 700
3035 DISP_SCREED_CTRL_LCS_POTI_TIME_LOCK_SPEED_U_NORM A121 R102 -- 1 1 0 1000

_disp_comm_list_BF800C_2013_04_16.xls rev_10 1 of 6
BF800C - Display Codes / Command Codes
3036 DISP_SCREED_CTRL_LCS_POTI_BALANCE_SPEED_U_VOLT A121 R123 X68:9 10 mV 70 700 R123 optoinally
3037 DISP_SCREED_CTRL_LCS_POTI_BALANCE_SPEED_U_NORM A121 R123 -- 1 1 0 1000 R123 optoinally
3038 DISP_SCREED_CTRL_LCS_REQUESTS_FROM_SWITCHES A121 S249, S250 X72:11, X72:1, X72:2 1 1 1 1100 xxx1 = Up request, xx1x = Stop request, x1xx = Float request, 1xxx = Boost request
3040 DISP_SCREED_CTRL_LCS_VALVE_PRESS_B1_CURRENT_COMMAND A121 Y230 -- 1 mA 0 720 Depending on poti max. values

The min. current might be equal to zero in case the supply voltage is below 25.6 V.
3041 DISP_SCREED_CTRL_LCS_VALVE_PRESS_B1_CURRENT_FEEDBACK A121 Y230 X68:43 1 mA 40 720 The max. current might be below the given max. value depending on the poti max. values.
3042 DISP_SCREED_CTRL_LCS_VALVE_PRESS_B1_CURRENT_MIN_PAR A121 Y230 -- 1 mA 80 120
3043 DISP_SCREED_CTRL_LCS_VALVE_PRESS_B1_CURRENT_MAX_PAR A121 Y230 -- 1 mA 680 720
Depending on poti max. values..
3044 DISP_SCREED_CTRL_LCS_VALVE_PRESS_B2_CURRENT_COMMAND A121 Y297 -- 1 mA 0 720 Y297 optionally

The min. current might be equal to zero in case the supply voltage is below 25.6 V.
3045 DISP_SCREED_CTRL_LCS_VALVE_PRESS_B2_CURRENT_FEEDBACK A121 Y297 X68:44 1 mA 40 720 The max. current might be below the given max. value depending on the poti max. values.
3046 DISP_SCREED_CTRL_LCS_VALVE_PRESS_B2_CURRENT_MIN_PAR A121 Y297 -- 1 mA 80 120 Y297 optionally
3047 DISP_SCREED_CTRL_LCS_VALVE_PRESS_B2_CURRENT_MAX_PAR A121 Y297 -- 1 mA 680 720 Y297 optionally
3050 DISP_SCREED_CTRL_LCS_VALVE_A1_OUTPUT_VOLTAGE A121 Y226 X68:62 1 V 0.0 28.0
3051 DISP_SCREED_CTRL_LCS_VALVE_A2_OUTPUT_VOLTAGE A121 Y227 X68:20 1 V 0.0 28.0
3052 DISP_SCREED_CTRL_LCS_VALVE_A3_OUTPUT_VOLTAGE A121 Y228 X68:64 1 V 0.0 28.0
3053 DISP_SCREED_CTRL_LCS_VALVE_A4_2_3_OUTPUT_VOLTAGE A121 Y229 X68:51 1 V 0.0 28.0
3054 DISP_SCREED_CTRL_LCS_VALVE_A8_2_6_OUTPUT_VOLTAGE A121 Y296 X68:42 1 V 0.0 28.0
3110 DISP_TAMPER_CTRL_PUMP_CURRENT_COMMAND A121 Y224 -- 1 mA 0 700
3111 DISP_TAMPER_CTRL_PUMP_CURRENT_FEEDBACK A121 Y224 X68:22 1 mA 40 700 The min. current might be equal to zero in case the supply voltage is below 25.6 V.
3112 DISP_TAMPER_CTRL_PUMP_CURRENT_MIN_PAR A121 Y224 -- 1 mA 100 300
3113 DISP_TAMPER_CTRL_PUMP_CURRENT_MAX_PAR A121 Y224 -- 1 mA 450 700
3160 DISP_VIBRATION_CTRL_PUMP_CURRENT_COMMAND A121 Y225 -- 1 mA 0 700
3161 DISP_VIBRATION_CTRL_PUMP_CURRENT_FEEDBACK A121 Y225 X68:21 1 mA 40 700 The min. current might be equal to zero in case the supply voltage is below 25.6 V.
3162 DISP_VIBRATION_CTRL_PUMP_CURRENT_MIN_PAR A121 Y225 -- 1 mA 100 300
3163 DISP_VIBRATION_CTRL_PUMP_CURRENT_MAX_PAR A121 Y225 -- 1 mA 450 700
3170 DISP_SCREED_EXT_VALVE_LEFT_OPEN_OUTPUT_VOLTAGE A121 Y216 X68:2 1 V 0.0 28.0
3171 DISP_SCREED_EXT_VALVE_LEFT_CLOSE_OUTPUT_VOLTAGE A121 Y217 X68:3 1 V 0.0 28.0
3172 DISP_SCREED_EXT_VALVE_RIGHT_OPEN_OUTPUT_VOLTAGE A121 Y218 X68:24 1 V 0.0 28.0
3173 DISP_SCREED_EXT_VALVE_RIGHT_CLOSE_OUTPUT_VOLTAGE A121 Y219 X68:25 1 V 0.0 28.0
3180 DISP_SCREED_EXT_REQUEST_FROM_SWITCH_LEFT_OPEN_D A121 S239 X68:18 1 1 0 1 0 = OFF, 1 = ON
3181 DISP_SCREED_EXT_REQUEST_FROM_SWITCH_LEFT_OPEN_S A121 S241 X68:38 1 1 0 1 0 = OFF, 1 = ON
3182 DISP_SCREED_EXT_REQUEST_FROM_SWITCH_LEFT_CLOSE_D A121 S239 X68:11 1 1 0 1 0 = OFF, 1 = ON
3183 DISP_SCREED_EXT_REQUEST_FROM_SWITCH_LEFT_CLOSE_S A121 S241 X68:39 1 1 0 1 0 = OFF, 1 = ON
3184 DISP_SCREED_EXT_REQUEST_FROM_SWITCH_RIGHT_OPEN_D A121 S240 X68:19 1 1 0 1 0 = OFF, 1 = ON
3185 DISP_SCREED_EXT_REQUEST_FROM_SWITCH_RIGHT_OPEN_S A121 S242 X68:15 1 1 0 1 0 = OFF, 1 = ON
3186 DISP_SCREED_EXT_REQUEST_FROM_SWITCH_RIGHT_CLOSE_D A121 S240 X68:45 1 1 0 1 0 = OFF, 1 = ON
3187 DISP_SCREED_EXT_REQUEST_FROM_SWITCH_RIGHT_CLOSE_S A121 S242 X68:41 1 1 0 1 0 = OFF, 1 = ON
3190 DISP_SCREED_LEV_REQUEST_FROM_SWITCH_LEFT_UP A121 S243, S245 X68:31 1 1 0 1 0 = OFF, 1 = ON
3191 DISP_SCREED_LEV_REQUEST_FROM_SWTCH_LEFT_DOWN A121 S243, S245 X68:32 1 1 0 1 0 = OFF, 1 = ON
3192 DISP_SCREED_LEV_REQUEST_FROM_SWITCH_RIGHT_UP A121 S244, S246 X68:29 1 1 0 1 0 = OFF, 1 = ON
3193 DISP_SCREED_LEV_REQUEST_FROM_SWITCH_RIGHT_DOWN A121 S244, S246 X68:30 1 1 0 1 0 = OFF, 1 = ON
3195 DISP_SCREED_LEV_VALVE_LEFT_UP_OUTPUT_VOLTAGE A121 Y220 X68:46 1 V 0.0 28.0
3196 DISP_SCREED_LEV_VALVE_LEFT_DOWN_OUTPUT_VOLTAGE A121 Y221 X68:47 1 V 0.0 28.0
3197 DISP_SCREED_LEV_VALVE_RIGHT_UP_OUTPUT_VOLTAGE A121 Y222 X68:48 1 V 0.0 28.0
3198 DISP_SCREED_LEV_VALVE_RIGHT_DOWN_OUTPUT_VOLTAGE A121 Y223 X68:49 1 V 0.0 28.0
3200 DISP_SW_VERSION_NUMBER A121 A121 -- 1 1 -- --
3200 DISP_SW_VERSION_NUMBER A121 A121 -- 1 1 -- --
4009 DISP_MCU_FEEDER_SUPPLY_RELAY_OUTPUT_VOLTAGE A122 K163 X69:22 1 V 0.0 28.0
4010 DISP_AUGER_CTRL_POTI_LEFT_U_VOLT A122 R98 X69:8 100 mV 7 77
4011 DISP_AUGER_CTRL_POTI_RIGHT_U_VOLT A122 R99 X69:9 100 mV 7 77
4012 DISP_AUGER_CTRL_XDUCER_LEFT_CURRENT A122 R98 X69:8 0.01 mA 370 20500 20-step-switch
4013 DISP_AUGER_CTRL_XDUCER_RIGHT_CURRENT A122 R99 X69:9 0.01 mA 370 20500 20-step-switch
4020 DISP_AUGER_CTRL_SONIC_LEFT_DUTY_CYCLE A122 Sonic sensor left X69:18, X25:D 1 % 5 65
4021 DISP_AUGER_CTRL_SONIC_LEFT_NORMED_VALUE A122 A122 -- 1 1 0 1000
4022 DISP_AUGER_CTRL_SONIC_RIGHT_DUTY_CYCLE A122 Sonic sensor right X69:19, X26:D 1 % 5 65
4023 DISP_AUGER_CTRL_SONIC_RIGHT_NORMED_VALUE A122 A122 -- 1 1 0 1000
4030 DISP_AUGER_CTRL_PUMP_LEFT_CURRENT_COMMAND_FWD A122 Y210 -- 1 mA 0 700
4031 DISP_AUGER_CTRL_PUMP_LEFT_CURRENT_FEEDBACK_FWD A122 Y210 X69:46 1 mA 40 700 The min. current might be equal to zero in case the supply voltage is below 25.6 V.
4032 DISP_AUGER_CTRL_PUMP_LEFT_CURRENT_MIN_FWD_PAR A122 Y210 -- 1 mA 180 220
4033 DISP_AUGER_CTRL_PUMP_LEFT_CURRENT_MAX_FWD_PAR A122 Y210 -- 1 mA 500 700
4035 DISP_AUGER_CTRL_PUMP_LEFT_CURRENT_COMMAND_BWD A122 Y211 -- 1 mA 0 620
4036 DISP_AUGER_CTRL_PUMP_LEFT_CURRENT_FEEDBACK_BWD A122 Y211 X69:47 1 mA 40 620 The min. current might be equal to zero in case the supply voltage is below 25.6 V.
4037 DISP_AUGER_CTRL_PUMP_LEFT_CURRENT_MIN_BWD_PAR A122 Y211 -- 1 mA 180 220
4038 DISP_AUGER_CTRL_PUMP_LEFT_CURRENT_MAX_BWD_PAR A122 Y211 -- 1 mA 580 620
4040 DISP_AUGER_CTRL_PUMP_RIGHT_CURRENT_COMMAND_FWD A122 Y212 -- 1 mA 0 700
4041 DISP_AUGER_CTRL_PUMP_RIGHT_CURRENT_FEEDBACK_FWD A122 Y212 X69:48 1 mA 40 700 The min. current might be equal to zero in case the supply voltage is below 25.6 V.

_disp_comm_list_BF800C_2013_04_16.xls rev_10 2 of 6
BF800C - Display Codes / Command Codes
4042 DISP_AUGER_CTRL_PUMP_RIGHT_CURRENT_MIN_FWD_PAR A122 Y212 -- 1 mA 180 220
4043 DISP_AUGER_CTRL_PUMP_RIGHT_CURRENT_MAX_FWD_PAR A122 Y212 -- 1 mA 500 700
4045 DISP_AUGER_CTRL_PUMP_RIGHT_CURRENT_COMMAND_BWD A122 Y213 -- 1 mA 0 620
4046 DISP_AUGER_CTRL_PUMP_RIGHT_CURRENT_FEEDBACK_BWD A122 Y213 X69:49 1 mA 40 620 The min. current might be equal to zero in case the supply voltage is below 25.6 V.
4047 DISP_AUGER_CTRL_PUMP_RIGHT_CURRENT_MIN_BWD_PAR A122 Y213 -- 1 mA 180 220
4048 DISP_AUGER_CTRL_PUMP_RIGHT_CURRENT_MAX_BWD_PAR A122 Y213 -- 1 mA 580 620
4080 DISP_AUGER_CTRL_REQUEST_FROM_SWITCH_LEFT_AUTO A122 S232 X69:45 1 1 0 1 0 = OFF, 1 = ON
4081 DISP_AUGER_CTRL_REQUEST_FROM_SWITCH_LEFT_MAN A122 S232 X69:12 1 1 0 1 0 = OFF, 1 = ON
4082 DISP_AUGER_CTRL_REQUEST_FROM_SWITCH_LEFT_REV A122 S230 X69:36 1 1 0 1 0 = OFF, 1 = ON
4083 DISP_AUGER_CTRL_REQUEST_FROM_SWITCH_RIGHT_AUTO A122 S233 X69:11 1 1 0 1 0 = OFF, 1 = ON
4084 DISP_AUGER_CTRL_REQUEST_FROM_SWITCH_RIGHT_MAN A122 S223 X69:13 1 1 0 1 0 = OFF, 1 = ON
4085 DISP_AUGER_CTRL_REQUEST_FROM_SWITCH_RIGHT_REV A122 S231 X69:37 1 1 0 1 0 = OFF, 1 = ON
4086 DISP_AUGER_CTRL_REQUEST_FROM_SWITCH_BOX_UP A122 S236 X72:7 1 1 0 1 0 = OFF, 1 = ON
4087 DISP_AUGER_CTRL_REQUEST_FROM_SWITCH_BOX_DOWN A122 S236 X72:8 1 1 0 1 0 = OFF, 1 = ON
4090 DISP_AUGER_CTRL_VALVE_BOX_UP_OUTPUT_VOLTAGE A122 Y214 X69:50 1 V 0.0 28.0
4091 DISP_AUGER_CTRL_VALVE_BOX_DOWN_OUTPUT_VOLTAGE A122 Y215 X69:51 1 V 0.0 28.0
4100 DISP_CONVEYOR_CTRL_POTI_LEFT_U_VOLT A122 R96 X69:6 100 mV 7 77
4101 DISP_CONVEYOR_CTRL_POTI_RIGHT_U_VOLT A122 R97 X69:7 100 mV 7 77
4102 DISP_CONVEYOR_CTRL_XDUCER_LEFT_CURRENT A122 R96 X69:6 0.01 mA 370 20500 20-step-switch
4103 DISP_CONVEYOR_CTRL_XDUCER_RIGHT_CURRENT A122 R97 X69:7 0.01 mA 370 20500 20-step-switch
4110 DISP_CONVEYOR_CTRL_SONIC_LEFT_DUTY_CYCLE A122 Sonic sensor left X69:34, X29:D 1 % 5 95
4111 DISP_CONVEYOR_CTRL_SONIC_LEFT_NORMED_VALUE A122 A122 -- 1 1 0 1000
4112 DISP_CONVEYOR_CTRL_SONIC_RIGHT_DUTY_CYCLE A122 Sonic sensor right X69:35, X30:D 1 % 5 95
4113 DISP_CONVEYOR_CTRL_SONIC_RIGHT_NORMED_VALUE A122 A122 -- 1 1 0 1000
4115 DISP_CONVEYOR_CTRL_REQUEST_FROM_SWITCH_LEFT_AUTO A122 S226 X72:5 1 1 0 1 0 = OFF, 1 = ON
4116 DISP_CONVEYOR_CTRL_REQUEST_FROM_SWITCH_LEFT_MAN A122 S226 X69:14 1 1 0 1 0 = OFF, 1 = ON
4117 DISP_CONVEYOR_CTRL_REQUEST_FROM_SWITCH_RIGHT_AUTO A122 S227 X72:6 1 1 0 1 0 = OFF, 1 = ON
4118 DISP_CONVEYOR_CTRL_REQUEST_FROM_SWITCH_RIGHT_MAN A122 S227 X69:16 1 1 0 1 0 = OFF, 1 = ON
4119 DISP_CONVEYOR_CTRL_REQUEST_FROM_SWITCH_BOTH_REV A122 S225 X69:15 1 1 0 1 0 = OFF, 1 = ON
4120 DISP_CONVEYOR_CTRL_PUMP_LEFT_CURRENT_COMMAND_FWD A122 Y207 -- 1 mA 0 700
4121 DISP_CONVEYOR_CTRL_PUMP_LEFT_CURRENT_FEEDBACK_FWD A122 Y207 X69:20 1 mA 40 700 The min. current might be equal to zero in case the supply voltage is below 25.6 V.
4122 DISP_CONVEYOR_CTRL_PUMP_LEFT_CURRENT_MIN_FWD_PAR A122 Y207 -- 1 mA 180 220
4123 DISP_CONVEYOR_CTRL_PUMP_LEFT_CURRENT_MAX_FWD_PAR A122 Y207 -- 1 mA 500 700
4125 DISP_CONVEYOR_CTRL_PUMP_LEFT_CURRENT_COMMAND_BWD A122 Y206 -- 1 mA 0 570
4126 DISP_CONVEYOR_CTRL_PUMP_LEFT_CURRENT_FEEDBACK_BWD A122 Y206 X69:21 1 mA 40 570 The min. current might be equal to zero in case the supply voltage is below 25.6 V.
4127 DISP_CONVEYOR_CTRL_PUMP_LEFT_CURRENT_MIN_BWD_PAR A122 Y206 -- 1 mA 180 220
4128 DISP_CONVEYOR_CTRL_PUMP_LEFT_CURRENT_MAX_BWD_PAR A122 Y206 -- 1 mA 500 570
4130 DISP_CONVEYOR_CTRL_PUMP_RIGHT_CURRENT_COMMAND_FWD A122 Y209 -- 1 mA 0 700
4131 DISP_CONVEYOR_CTRL_PUMP_RIGHT_CURRENT_FEEDBACK_FWD A122 Y209 X69:42 1 mA 40 700 The min. current might be equal to zero in case the supply voltage is below 25.6 V.
4132 DISP_CONVEYOR_CTRL_PUMP_RIGHT_CURRENT_MIN_FWD_PAR A122 Y209 -- 1 mA 180 220
4133 DISP_CONVEYOR_CTRL_PUMP_RIGHT_CURRENT_MAX_FWD_PAR A122 Y209 -- 1 mA 500 700
4135 DISP_CONVEYOR_CTRL_PUMP_RIGHT_CURRENT_COMMAND_BWD A122 Y208 -- 1 mA 0 570
4136 DISP_CONVEYOR_CTRL_PUMP_RIGHT_CURRENT_FEEDBACK_BWD A122 Y208 X69:43 1 mA 40 570 The min. current might be equal to zero in case the supply voltage is below 25.6 V.
4137 DISP_CONVEYOR_CTRL_PUMP_RIGHT_CURRENT_MIN_BWD_PAR A122 Y208 -- 1 mA 180 220
4138 DISP_CONVEYOR_CTRL_PUMP_RIGHT_CURRENT_MAX_BWD_PAR A122 Y208 -- 1 mA 500 570
4170 DISP_HOPPER_CTRL_REQUEST_FROM_SWITCH_LEFT_UP A122 S222 X69:38 1 1 0 1 0 = OFF, 1 = ON
4171 DISP_HOPPER_CTRL_REQUEST_FROM_SWITCH_LEFT_DOWN A122 S222 X69:62 1 1 0 1 0 = OFF, 1 = ON
4172 DISP_HOPPER_CTRL_REQUEST_FROM_SWITCH_RIGHT_UP A122 S223 X69:39 1 1 0 1 0 = OFF, 1 = ON
4173 DISP_HOPPER_CTRL_REQUEST_FROM_SWITCH_RIGHT_DOWN A122 S223 X69:63 1 1 0 1 0 = OFF, 1 = ON
4174 DISP_HOPPER_CTRL_REQUEST_FROM_SWITCH_FLAP_UP A122 S283 X69:29 1 1 0 1 0 = OFF, 1 = ON
4175 DISP_HOPPER_CTRL_REQUEST_FROM_SWITCH_FLAP_DOWN A122 S283 X69:30 1 1 0 1 0 = OFF, 1 = ON
4180 DISP_HOPPER_CTRL_VALVE_LEFT_UP_OUTPUT_VOLTAGE A122 Y203 X69:3 1 V 0.0 28.0
4181 DISP_HOPPER_CTRL_VALVE_LEFT_DOWN_OUTPUT_VOLTAGE A122 Y202 X69:2 1 V 0.0 28.0
4182 DISP_HOPPER_CTRL_VALVE_RIGHT_UP_OUTPUT_VOLTAGE A122 Y205 X69:25 1 V 0.0 28.0
4183 DISP_HOPPER_CTRL_VALVE_RIGHT_DOWN_OUTPUT_VOLTAGE A122 Y204 X69:24 1 V 0.0 28.0
4184 DISP_HOPPER_CTRL_VALVE_FLAP_UP_OUTPUT_VOLTAGE A122 Y287 X69:44 1 V 0.0 28.0
4185 DISP_HOPPER_CTRL_VALVE_FLAP_DOWN_OUTPUT_VOLTAGE A122 Y288 X69:64 1 V 0.0 28.0
4200 DISP_SW_VERSION_NUMBER A122 A122 -- 1 1 -- --
4200 DISP_SW_VERSION_NUMBER A122 A122 -- 1 1 -- --
5001 DISP_ENGINE_COMMAND_RPM A34 A34 -- 1 rpm 900 2000
5002 DISP_ENGINE_IDLE_MODE A34 S120 X35:38, X35:39 1 1 0 2 0 = Low, 1 = Eco, 2 = High
5010 DISP_ENGINE_LOW_RPM_PAR A34 A34 -- 1 rpm 800 1000
5011 DISP_ENGINE_ECO_RPM_PAR A34 A34 -- 1 rpm 1600 1800
5012 DISP_ENGINE_HIGH_RPM_PAR A34 A34 -- 1 rpm 1900 2100
5020 DISP_ENGINE_OIL_PRESSURE_STATE A34 A48 -- 1 1 0 1 0 = Pressure normal, 1 = Pressure abnormal
5021 DISP_ENGINE_COOLANT_LEVEL_STATE A34 B55 X70:8 1 1 0 1 0 = Level ok, 1 = Level low
5024 DISP_ENGINE_MD_PLUS_STATE A34 A80 X70:7 1 1 0 1 0 = Not charging, 1 = Charging
5025 DISP_ENGINE_AIR_FILTER_STATE A34 B03 X70:6 1 1 0 1 0 = Filter clean, 1= Filter dirty
5026 DISP_ENGINE_FUEL_WATER_SEPARATOR_STATE A34 B124 -- 1 1 0 1 0 = No water in fuel, 1 = Water in fuel

_disp_comm_list_BF800C_2013_04_16.xls rev_10 3 of 6
BF800C - Display Codes / Command Codes
0 = Regeneration not needed, 1 = Regeneration needed lowest level,
2 = Regeneration needed moderat level, 3 = Regeneration needed highest level, 7 = Not
5200 DISP_ENGINE_DPF_STATE A34 A48 -- 1 1 0 7 available
5201 DISP_ENGINE_DPF_ASH_LOAD_PERCENTAGE A34 A49 -- 1 % 0 250 8888 = Value form EEC invalid
5202 DISP_ENGINE_DPF_LAMP_COMMAND A34 A50 -- 1 1 0 7 0 = Lamp off, 1 = Lamp solid on, 4 = Lamp fast blink, 5 = Lamp slow blink, 7 = Not available
5203 DISP_ENGINE_DPF_ACTIVE_REGEN_STATE A34 A51 -- 1 1 0 3 0 = Not Active, 1 = Active, 2 = Regeneration needed, 3 = Not available
5204 DISP_ENGINE_DPF_ACTIVE_REGEN_INHIBIT_STATE A34 A52 -- 1 1 0 1 0 = Not inhibited, 1 = Inhibited
5205 DISP_ENGINE_DPF_ACTIVE_REGEN_INHIBIT_BY_SWITCH A34 A53 -- 1 1 0 1 0 = Not inhibited, 1 = Inhibited
5206 DISP_ENGINE_DPF_ACTIVE_REGEN_INHIBIT_ACCEL_OFF_IDLE A34 A54 -- 1 1 0 1 0 = Not inhibited, 1 = Inhibited
5207 DISP_ENGINE_DPF_ACTIVE_REGEN_INHIBIT_OUT_OF_NEUTRAL A34 A55 -- 1 1 0 1 0 = Not inhibited, 1 = Inhibited
5208 DISP_ENGINE_DPF_ACTIVE_REGEN_INHIBIT_PARK_BRAKE_NOT_SET A34 A56 -- 1 1 0 1 0 = Not inhibited, 1 = Inhibited
5209 DISP_ENGINE_DPF_ACTIVE_REGEN_INHIBIT_LOW_EXHAUST_TEMP A34 A57 -- 1 1 0 1 0 = Not inhibited, 1 = Inhibited
5210 DISP_ENGINE_DPF_ACTIVE_REGEN_INHIBIT_SYSTEM_FAULT_ACTIVE A34 A58 -- 1 1 0 1 0 = Not inhibited, 1 = Inhibited
5211 DISP_ENGINE_DPF_ACTIVE_REGEN_INHIBIT_SYSTEM_TIMEOUT A34 A59 -- 1 1 0 1 0 = Not inhibited, 1 = Inhibited
5212 DISP_ENGINE_DPF_ACTIVE_REGEN_INHIBIT_LOCK_OUT A34 A60 -- 1 1 0 1 0 = Not inhibited, 1 = Inhibited
5410 DISP_FAN_DRIVE_ACTUAL_TEMP_VALUE_COOLANT_WATER A34 A48 -- 1 degC -10 110
5411 DISP_FAN_DRIVE_ACTUAL_TEMP_VALUE_INTAKE_MANIFOLD A34 A48 -- 1 degC -10 110
5412 DISP_FAN_DRIVE_ACTUAL_TEMP_VALUE_HYDRAULIC_OIL A34 B98 X71:3, X71:10 1 degC -10 110
5413 DISP_FAN_DRIVE_ACTUAL_TEMP_VALUE_AMBIENT A34 B218 X73:3, X73:10 1 degC -10 110
5414 DISP_FAN_DRIVE_VALVE_SPEED_CONTORL_COMMAD A34 A34 -- 1 1 0 1000
5415 DISP_FAN_DRIVE_VALVE_SPEED_CONTORL_CURRENT_FEEDBACK A34 Y286 X35:64 1 mA 40 700 The min. current might be equal to zero in case the supply voltage is below 25.6 V.
0 = SpeedConstant, 1 = SpeedOff, 2 = SpeedLow, 3 = SpeedBaseStopped,
5416 DISP_FAN_DRIVE_CONTROL_MODE_COOLANT_WATER A34 A34 -- 1 1 0 7 4 = SpeedBase, 5 = SpeedControlled, 6 = SpeedMax, 7 = SpeedBoost
0 = SpeedConstant, 1 = SpeedOff, 2 = SpeedLow, 3 = SpeedBaseStopped,
5417 DISP_FAN_DRIVE_CONTROL_MODE_INTAKE_MANIFOLD A34 A34 -- 1 1 0 7 4 = SpeedBase, 5 = SpeedControlled, 6 = SpeedMax, 7 = SpeedBoost
0 = SpeedConstant, 1 = SpeedOff, 2 = SpeedLow, 3 = SpeedBaseStopped,
5418 DISP_FAN_DRIVE_CONTROL_MODE_HYDRAULIC_OIL A34 A34 -- 1 1 0 7 4 = SpeedBase, 5 = SpeedControlled, 6 = SpeedMax, 7 = SpeedBoost
5500 DISP_HYDRAULIC_FILTER_CHARGE_STATE A34 B42 X70:2 1 1 0 1 0 = Filter clean, 1= Filter dirty
B122, B121, B22,
5501 DISP_HYDRAULIC_FILTER_SWITCH_STATE A34 B21 X70:3 1 1 0 1 0 = Filter clean, 1= Filter dirty
5504 DISP_HYDRAULIC_OIL_TEMP_STATE A34 B98 -- 1 1 1 3 1 = Error, 2 = Normal, 3 = OverTemp
5505 DISP_HYDRAULIC_OIL_TEMP A34 B98 -- 1 degC -24 108
5508 DISP_HYDRAULIC_DIRT_SWITCH_STATE A34 B19 X70:11 1 1 0 1 0 = Clean, 1= Dirty
5601 DISP_POWER_SYNC_OUTPUT_VOLTAGE A34 A34 X35:11 1 V 0.0 28.0
5610 DISP_POWER_SYNC_PERMANENT_ON A34 A34 -- 1 1 0 1 0 = Permanent On disabled, 1 = Permanent On enabled

Control unit
processing
Command Code Description Link Service Manual
command
code
500 COMM_DRIVE_AGAINST_BRAKE_ON A34 Settings -> Tractor Control -> Propel system -> Drive against closed brake
501 COMM_DRIVE_AGAINST_BRAKE_OFF A34 Settings -> Tractor Control -> Propel system -> Drive against closed brake
700 COMM_DISPLAY_MEMORIZED_ERRORS_ON A34 Fault log – display and delete -> Showing stored faults
701 COMM_DISPLAY_MEMORIZED_ERRORS_OFF A34 Fault log – display and delete -> Showing stored faults
705 COMM_DISPLAY_MEMORIZED_ERRORS_ON_EXTENDED A34 Fault log – display and delete -> Showing saved faults with operating hours
706 COMM_DISPLAY_MEMORIZED_ERRORS_OFF_EXTENDED A34 Fault log – display and delete -> Showing saved faults with operating hours
710 COMM_CLEAR_ALL_ERRORS A34 Fault log – display and delete -> Delete all stored faults
750 COMM_DISPLAY_MEMORIZED_ENGINE_ERRORS_ON A34
751 COMM_DISPLAY_MEMORIZED_ENGINE_ERRORS_OFF A34
760 COMM_CLEAR_ALL_MEMORIZED_ENGINE_ERRORS A34
1090 COMM_PROPEL_PUMP_LEARN_START_CURRENTS_ENABLE A34 Settings -> Tractor Control -> Propel system ->Learn function for the start currents of the propel pumps (BF800 C only)
1091 COMM_PROPEL_PUMP_LEARN_START_CURRENTS_LEFT A34 Settings -> Tractor Control -> Propel system ->Learn function for the start currents of the propel pumps (BF800 C only)
1092 COMM_PROPEL_PUMP_LEARN_START_CURRENTS_RIGHT A34 Settings -> Tractor Control -> Propel system ->Learn function for the start currents of the propel pumps (BF800 C only)
1093 COMM_PROPEL_PUMP_LEARN_START_CURRENTS_DISABLE A34 Settings -> Tractor Control -> Propel system ->Learn function for the start currents of the propel pumps (BF800 C only)
1095 COMM_PROPEL_PUMP_TEACH_START_CURRENTS_ENABLE A34 Settings -> Tractor Control -> Propel system ->Teach the forward and backward start currents of the propel pumps (BF800 C only)
1096 COMM_PROPEL_PUMP_TEACH_START_CURRENTS_FORWARD A34 Settings -> Tractor Control -> Propel system ->Teach the forward and backward start currents of the propel pumps (BF800 C only)
1097 COMM_PROPEL_PUMP_TEACH_START_CURRENTS_BACKWARD A34 Settings -> Tractor Control -> Propel system ->Teach the forward and backward start currents of the propel pumps (BF800 C only)
1098 COMM_PROPEL_PUMP_TEACH_START_CURRENTS_DISABLE A34 Settings -> Tractor Control -> Propel system ->Teach the forward and backward start currents of the propel pumps (BF800 C only)
1100 COMM_PROPEL_PARAM_CHANGE_ENABLE A34
1108 COMM_PROPEL_SPEED_CAPTURE_ENABLE A34
1109 COMM_PROPEL_SPEED_CAPTURE_DISABLE A34
1110 COMM_PROPEL_SPEED_CONTROLLER_ENABLE A34
1111 COMM_PROPEL_SPEED_CONTROLLER_DISABLE A34
1112 COMM_PROPEL_HYDR_GEAR_FORCE_SHIFT_TO_LOW_BY_STEERING_ENABLE A34
1113 COMM_PROPEL_HYDR_GEAR_FORCE_SHIFT_TO_LOW_BY_STEERING_DISABLE A34
1114 COMM_PROPEL_HYDR_GEAR_FORCE_SHIFT_TO_LOW_BY_WORK_MODE_ENABLE A34
1115 COMM_PROPEL_HYDR_GEAR_FORCE_SHIFT_TO_LOW_BY_WORK_MODE_DISABLE A34
1116 COMM_PROPEL_ENGINE_RPM_COMPENSATION_WORK_LOW_ENABLE A34

_disp_comm_list_BF800C_2013_04_16.xls rev_10 4 of 6
BF800C - Display Codes / Command Codes
1117 COMM_PROPEL_ENGINE_RPM_COMPENSATION_WORK_LOW_DISABLE A34
1121 COMM_PROPEL_SPEED_COMMAND_BY_BOOST_BUTTON_ENABLE A34 Settings -> Tractor Control -> Propel system -> Speed command by Boost button in case of a broken speed potentiometer
1122 COMM_PROPEL_SPEED_COMMAND_BY_BOOST_BUTTON_DISABLE A34 Settings -> Tractor Control -> Propel system -> Speed command by Boost button in case of a broken speed potentiometer
1123 COMM_PROPEL_SLOPE_CAPTURE_ENABLE A34
1124 COMM_PROPEL_SLOPE_CAPTURE_DISABLE A34
1125 COMM_PROPEL_SLOPE_COMMAND_OFFSET_ENABLE A34
1126 COMM_PROPEL_SLOPE_COMMAND_OFFSET_DISABLE A34
1127 COMM_PROPEL_SLOPE_BRAKE_APPLY_ENABLE A34
1128 COMM_PROPEL_SLOPE_BRAKE_APPLY_DISABLE A34
1130 COMM_PROPEL_POTI_SPEED_TYPE_CROSS_SIG_ENABLE A34 Settings -> Tractor Control -> Propel system -> Change speed potentiometer type
1131 COMM_PROPEL_POTI_SPEED_TYPE_CROSS_SIG_DISABLE A34 Settings -> Tractor Control -> Propel system -> Change speed potentiometer type
2021 COMM_PROPEL_STEER_SPIN_BY_BOOST_BUTTON_ENABLE A34 Settings -> Tractor Control -> Propel system -> Steer with spin switch
2022 COMM_PROPEL_STEER_SPIN_BY_BOOST_BUTTON_DISABLE A34 Settings -> Tractor Control -> Propel system -> Steer with spin switch
3001 COMM_SCU_PARAM_CHANGE_ENABLE A121
3002 COMM_SCU_PARAM_CHANGE_DISABLE A121
3003 COMM_SCU_SET_PARAM_DEFAULT A121 Settings -> Screed Control -> Miscellaneous -> Return to the default values
3010 COMM_SCREED_CTRL_LCS_ENABLE A121
3011 COMM_SCREED_CTRL_LCS_DISABLE A121
3012 COMM_SCREED_CTRL_LCS_DOUBLE_LCS_ENABLE A121
3013 COMM_SCREED_CTRL_LCS_DOUBLE_LCS_DISABLE A121
3014 COMM_SCREED_CTRL_LCS_ENABLE_POTI_DEFAULT_VALUES A121
3015 COMM_SCREED_CTRL_LCS_DISABLE_POTI_DEFAULT_VALUES A121
3016 COMM_SCREED_CTRL_LCS_TIME_LOCK_PRESS_EQUAL_TO_WORK_PRESS A121
3017 COMM_SCREED_CTRL_LCS_TIME_LOCK_PRESS_EQUAL_TO_STOP_PRESS A121
3018 COMM_SCREED_CTRL_LCS_TEACH_POTI_MAX_VALUES A121 Settings -> Screed Control -> Teach L.C.S. potentiometers max. values
3019 COMM_SCREED_CTRL_LCS_TEACH_POTI_WORK_MAX A121 Settings -> Screed Control -> Teach L.C.S. potentiometers max. values
3020 COMM_SCREED_CTRL_LCS_TEACH_POTI_STOP_MAX A121 Settings -> Screed Control -> Teach L.C.S. potentiometers max. values
3021 COMM_SCREED_CTRL_LCS_DISABLE_TEACH_POTI_MAX_VALUE A121 Settings -> Screed Control -> Teach L.C.S. potentiometers max. values
3022 COMM_SCREED_CTRL_LCS_ENABLE_BOOST_BY_STOP_POTI A121
3023 COMM_SCREED_CTRL_LCS_DISABLE_BOOST_BY_STOP_POTI A121
3024 COMM_SCREED_CTRL_LCS_LIMIT_WORK_PRESS_TO_STOP_PRESS_ENABLE A121
3025 COMM_SCREED_CTRL_LCS_LIMIT_WORK_PRESS_TO_STOP_PRESS_DISABLE A121
3102 COMM_TAMPER_CTRL_VARIABLE_RAMPS_COMMAND_ENABLE A121 Settings -> Screed Control -> Adjust tamper ramps
3103 COMM_TAMPER_CTRL_VARIABLE_RAMPS_COMMAND_DISABLE A121 Settings -> Screed Control -> Adjust tamper ramps
3104 COMM_TAMPER_CTRL_ADJUST_RAMP_OUT_ENABLE A121 Settings -> Screed Control -> Adjust tamper ramps
3105 COMM_TAMPER_CTRL_ADJUST_RAMP_OUT_DISABLE A121 Settings -> Screed Control -> Adjust tamper ramps
3106 COMM_TAMPER_CTRL_ADJUST_RAMP_BACK_ENABLE A121 Settings -> Screed Control -> Adjust tamper ramps
3107 COMM_TAMPER_CTRL_ADJUST_RAMP_BACK_DISABLE A121 Settings -> Screed Control -> Adjust tamper ramps
3116 COMM_TAMPER_CTRL_PRETENSION_ENABLE A121
3117 COMM_TAMPER_CTRL_PRETENSION_DISABLE A121
3120 COMM_TAMPER_CTRL_ADJUST_PUMP_CURRENT_MIN_ENABLE A121 Settings -> Screed Control -> Adjust currents for the tamper pump
3121 COMM_TAMPER_CTRL_ADJUST_PUMP_CURRENT_MIN_DISABLE A121 Settings -> Screed Control -> Adjust currents for the tamper pump
3122 COMM_TAMPER_CTRL_ADJUST_PUMP_CURRENT_MAX_ENABLE A121 Settings -> Screed Control -> Adjust currents for the tamper pump
3123 COMM_TAMPER_CTRL_ADJUST_PUMP_CURRENT_MAX_DISABLE A121 Settings -> Screed Control -> Adjust currents for the tamper pump
3150 COMM_VIBRATION_CTRL_RPM_COMPENSATION_ENABLE A121
3151 COMM_VIBRATION_CTRL_RPM_COMPENSATION_DISABLE A121
3164 COMM_VIBRATION_CTRL_ADJUST_PUMP_CURRENT_MIN_ENABLE A121 Settings -> Screed Control -> Adjust currents for the vibration pump
3165 COMM_VIBRATION_CTRL_ADJUST_PUMP_CURRENT_MIN_DISABLE A121 Settings -> Screed Control -> Adjust currents for the vibration pump
3166 COMM_VIBRATION_CTRL_ADJUST_PUMP_CURRENT_MAX_ENABLE A121 Settings -> Screed Control -> Adjust currents for the vibration pump
3167 COMM_VIBRATION_CTRL_ADJUST_PUMP_CURRENT_MAX_DISABLE A121 Settings -> Screed Control -> Adjust currents for the vibration pump
3210 COMM_DASA_VALUES_READ_WRITE_ENABLE A121 Settings -> Store / Restore settings
3211 COMM_DASA_READ_STORED_VALUES_FROM_DEVICE A121 Settings -> Store / Restore settings
3212 COMM_DASA_WRITE_STORED_VALUES_TO_DEVICE A121 Settings -> Store / Restore settings
4001 COMM_MCU_PARAM_CHANGE_ENABLE A122
4002 COMM_MCU_PARAM_CHANGE_DISABLE A122
4003 COMM_MCU_SET_PARAM_DEFAULT A122 Settings -> Material Flow Control -> Miscellaneous -> Return to the default values
4005 COMM_MCU_EMERGENCY_MODE_ENABLE A122
4006 COMM_MCU_EMERGENCY_MODE_DISABLE A122
4007 COMM_MCU_USE_POTENTIOMETERS A122
4008 COMM_MCU_USE_MULTISTEP_SWITCHES A122
4054 COMM_AUGER_CTRL_LOAD_LIMIT_ENABLE A122
4055 COMM_AUGER_CTRL_LOAD_LIMIT_DISABLE A122
4056 COMM_AUGER_CTRL_LIFT_BOX_WITH_SCREED_ENABLE A122 Settings -> Material flow control -> Enable / disable lifting auger box with screed
4057 COMM_AUGER_CTRL_LIFT_BOX_WITH_SCREED_DISABLE A122 Settings -> Material flow control -> Enable / disable lifting auger box with screed
4060 COMM_AUGER_CTRL_ADJUST_LEFT_PUMP_CURRENT_MAX_ENABLE A122 Settings -> Material flow control -> Adjust maximum current for augers pumps
4061 COMM_AUGER_CTRL_ADJUST_LEFT_PUMP_CURRENT_MAX_DISABLE A122 Settings -> Material flow control -> Adjust maximum current for augers pumps
4062 COMM_AUGER_CTRL_ADJUST_RIGHT_PUMP_CURRENT_MAX_ENABLE A122 Settings -> Material flow control -> Adjust maximum current for augers pumps
4063 COMM_AUGER_CTRL_ADJUST_RIGHT_PUMP_CURRENT_MAX_DISABLE A122 Settings -> Material flow control -> Adjust maximum current for augers pumps
4070 COMM_AUGER_CTRL_ADJUST_PUMP_MAN_RAMP_OUT_ENABLE A122 Settings -> Material flow control -> Adjust augers ramps
4071 COMM_AUGER_CTRL_ADJUST_PUMP_MAN_RAMP_OUT_DISABLE A122 Settings -> Material flow control -> Adjust augers ramps
4072 COMM_AUGER_CTRL_ADJUST_PUMP_MAN_RAMP_BACK_ENABLE A122 Settings -> Material flow control -> Adjust augers ramps

_disp_comm_list_BF800C_2013_04_16.xls rev_10 5 of 6
BF800C - Display Codes / Command Codes
4073 COMM_AUGER_CTRL_ADJUST_PUMP_MAN_RAMP_BACK_DISABLE A122 Settings -> Material flow control -> Adjust augers ramps
4074 COMM_AUGER_CTRL_ADJUST_PUMP_AUTO_RAMP_OUT_ENABLE A122 Settings -> Material flow control -> Adjust augers ramps
4075 COMM_AUGER_CTRL_ADJUST_PUMP_AUTO_RAMP_OUT_DISABLE A122 Settings -> Material flow control -> Adjust augers ramps
4076 COMM_AUGER_CTRL_ADJUST_PUMP_AUTO_RAMP_BACK_ENABLE A122 Settings -> Material flow control -> Adjust augers ramps
4077 COMM_AUGER_CTRL_ADJUST_PUMP_AUTO_RAMP_BACK_DISABLE A122 Settings -> Material flow control -> Adjust augers ramps
4140 COMM_CONVEYOR_CTRL_ADJUST_LEFT_PUMP_CURRENT_MAX_ENABLE A122 Settings -> Material flow control -> Adjust maximum current for conveyor pumps
4141 COMM_CONVEYOR_CTRL_ADJUST_LEFT_PUMP_CURRENT_MAX_DISABLE A122 Settings -> Material flow control -> Adjust maximum current for conveyor pumps
4142 COMM_CONVEYOR_CTRL_ADJUST_RIGHT_PUMP_CURRENT_MAX_ENABLE A122 Settings -> Material flow control -> Adjust maximum current for conveyor pumps
4143 COMM_CONVEYOR_CTRL_ADJUST_RIGHT_PUMP_CURRENT_MAX_DISABLE A122 Settings -> Material flow control -> Adjust maximum current for conveyor pumps
4154 COMM_CONVEYOR_CTRL_LOAD_LIMIT_ENABLE A122
4155 COMM_CONVEYOR_CTRL_LOAD_LIMIT_DISABLE A122
4157 COMM_MCU_USE_STABLE_SWITCHES_FOR_AUTOMATIC A122
4158 COMM_MCU_USE_MOMENTARY_SWITCHES_FOR_AUTOMATIC A122
4160 COMM_HOPPER_CTRL_FLAP_ENABLE A122 Settings -> Material flow control -> Enable/disable hoppers front flap
4161 COMM_HOPPER_CTRL_FLAP_DISABLE A122 Settings -> Material flow control -> Enable/disable hoppers front flap
4162 COMM_HOPPER_CTRL_COMBINED_MODE_ENABLE A122
4163 COMM_HOPPER_CTRL_COMBINED_MODE_DISABLE A122
4210 COMM_DASA_VALUES_READ_WRITE_ENABLE A122 Settings -> Store / Restore settings
4211 COMM_DASA_READ_STORED_VALUES_FROM_DEVICE A122 Settings -> Store / Restore settings
4212 COMM_DASA_WRITE_STORED_VALUES_TO_DEVICE A122 Settings -> Store / Restore settings
5030 COMM_ENGINE_ENABLE_SIMULATED_ENGINE A34
5031 COMM_ENGINE_DISABLE_SIMULATED_ENGINE A34
5032 COMM_ENGINE_CONFIG_ENG_SPEED_SWITCH_LOW_ECO_HIGH A34
5033 COMM_ENGINE_CONFIG_ENG_SPEED_SWITCH_LOW_ECO1_ECO2 A34
5034 COMM_ENGINE_CONFIG_ENG_SPEED_SWITCH_LOW_ECO1_ECO2_PWR_REQ_COMP A34
5040 COMM_ENGINE_FORCE_HEATING_IN_LOW_IDLE_ENABLE A34
5041 COMM_ENGINE_FORCE_HEATING_IN_LOW_IDLE_DISABLE A34
5053 COMM_ENGINE_STEADY_STATE_DETECT_ENABLE A34
5054 COMM_ENGINE_STEADY_STATE_DETECT_DISABLE A34
5410 COMM_FAN_DRIVE_SPEED_TEST_BASE A34
5411 COMM_FAN_DRIVE_SPEED_TEST_MAX A34
5412 COMM_FAN_DRIVE_SPEED_TEST_MIN A34
5413 COMM_FAN_DRIVE_SPEED_TEST_DISABLE A34
5414 COMM_FAN_DRIVE_SPEED_CONSTANT_ENABLE A34
5415 COMM_FAN_DRIVE_SPEED_CONSTANT_DISABLE A34
5611 COMM_POWER_SYNC_ENABLE_PERMANENT_ON A34
5612 COMM_POWER_SYNC_DISABLE_PERMANENT_ON A34
7010 COMM_ENABLE_MACHINE_TYPE_CHANGE A34 Settings -> General -> Machine type
8887 COMM_DASA_PARAMETERS_READ_WRITE_ENABLE A34 Settings -> Store / Restore settings
8888 COMM_DASA_RESTORE_TCU_PARAMETERS_FROM_DEVICE A34 Settings -> Store / Restore settings
8889 COMM_DASA_SAVE_TCU_PARAMETERS_IN_DEVICE A34 Settings -> Store / Restore settings

_disp_comm_list_BF800C_2013_04_16.xls rev_10 6 of 6