Professional Documents
Culture Documents
Release Notes
This file contains important supplementary and late-breaking information that may not
appear in the main product documentation. We recommend that you read this file in its
entirety.
Installation Contents
11058300_GDP_DataSheet.pdf
GDP Subsystem Application Data Sheet
11058298_GDP_SysDesc.pdf
GDP Subsystem Application System Description
11079203 GDP Subsystem
Files associated with entire GDP Subsystem Application
Project
Contains P1P file
70037315V110.P1P
Subsystem Application P1P file
11060612_BA_Tuning_Tracker_Antistall_Plug-ins_UM.pdf
Instructions for tuning the Antistall and Tracker plug-ins
CAN_Joystick.SCS
Replacement joystick input block for J1939 joysticks
70037315V110.lhx
Downloadable pre-compiled application
GDP.P1D
Subsystem Application P1D file
GDP.SCS
Subsystem Application with pin connections, fault history, and fault blinker removed.
GDP_Defaults.CSV
Read-Only Parameter source file containing application defaults
GDP_DEFS.lhx
Downloadable Read-Only Parameter file containing application defaults
AppBlock.SCS
GDP Application Block without plug-ins installed
DualPathSpdCtl_Jumper.SCS
Jumper block for Dual Path Speed Control plug-in socket
MaxCmdScale_Jumper.SCS
Jumper block for Max Command Scale plug-in socket
PowerDist_Jumper.SCS
Jumper block for Power Distribution plug-in socket
Trackstall_Jumper.SCS
Jumper block for Trackstall plug-in socket
Antistall Plug-in.SCS
Antistall plug-in
TempDerate Plug-in.SCS
Temp Derate plug-in
Trackstall Plug-in.SCS
Trackstall plug-in
Tracker Plug-in.SCS
Tracker plug-in
Release Notes.pdf
This file
Revision History
Subsystem Application version 1.10 (January 2018)
Version 1.10: What is New
• OS.ExecTimeOut is set to 10 ms, for which antistall tuning tables are provided.
• Logic that drives ServiceTool.DisableDownload and ServiceTool.DisableWrite now
uses digital inputs instead of analog joystick value
• Soft Ramp block for propel updated to latest version. This fixes an issue in which the
wrong ramp time was used in reverse.
• Temp Derate plug-in multiplier is initialized to 10000 on startup.
• If configured for proportional motors, the limit fed to the Dual Path Speed Control
plug-in stays at 10000 as long as AllowHR is true
• Error History block updated to latest version. This fixes an issue in which NV
memory write was continuously asserted
• Propel calibration status indicator blocks fixed to prevent a situation in which NV
memory write was continuously asserted
• New calibration P1D screens use panels to change visible content for each state
• Ported from MC050-012 to MC050-112 (legacy HWD)
Subsystem Application version 1.01 (April 2010)
Version 1.01: What is New
• Phase block modified so that it would compile in GUIDE 4.3.6
Version 1.01: Known issues
• Logic to prevent application and parameter downloads while driving (located in
OutputDrivers!SvcLock page) is active even when joystick is uncalibrated. If the
joystick neutral voltage is outside of the default neutral deadband, the operator must
move the joystick to begin calibration.
• OS.ExecTimeOut is set to 1 ms. See
11060612_AB_Tuning_Tracker_Antistall_Plug-ins_UM.pdf for information on
setting this value.
Copyright
©2004-2009 Sauer-Danfoss, Inc. All rights reserved.
Third party trademarks and brand names are the property of their respective owners.