Doc.No: PEIL-PED-DOC-PR1
INDUSTRIES Client : COMPAGNIE
LIMITED D’ELECTRICITE DU SENEGAL Subject: PIPE SUPPORT DETAILS
Sh: 1 of 6 Rev: R0
DESIGN OF
1.0 GENERAL:
This document covers the design of pedestals and foundations for Pipe supporting posts given
in drawing PEIL-CES-ME-PPL-WTP-143.
2.0 SCOPE:
This document contains the Design of pedestals using staad and foundation using spread sheet.
A three dimensional space frame model has been modeled using 2-noded beam and axial
elements in STAAD. The structure is modeled as a space frame. The secondary beams are also
modeled in the staad. All members are considered as standard Indian rolled sections.
Reactions obtained at the support from the main frame analysis is applied as loads on the
frame as per relevant IS codes. The different load combinations considered in the analysis are
considered here as well.
STAAD PRO V8i software is used for the analysis and design of pedestals. The global Co-
ordinate system used for the 3-dimensional model analysis is as follows. Following positive
co-ordinates is considered in the analysis and design.
The arrows indicate positive direction considered in staad. The input and output for u1 to u6
corresponds to as follows
PROMAC STAC CONSULTANTS Project : 1x125 MW TPP IN SENDOU
ENGINEERING
Doc.No: PEIL-PED-DOC-PR1
INDUSTRIES Client : COMPAGNIE
LIMITED D’ELECTRICITE DU SENEGAL Subject: PIPE SUPPORT DETAILS
Sh: 4 of 6 Rev: R0
u1 - Fx u4 - Mx
u2 - Fy u5 - My
u3 - Fz u6 - Mz
Sign Convention for positive values:
1. Forces
2. Moments
(If we grasp the axis in such a way that the thumb is in the direction of positive axis, the
folding fingers gives the direction of positive moment)
The analysis is carried out for all load combinations that was done for super structure design
using staad pro v8i. The design of all the members modeled is done using the in built facility
available in staad pro v8i as per Indian Codes and standards with limit state approach.
Based on all the pipe support data furnished, the maximum load acting on the pedestal is
400kg. The minimum pedestal size is 250 sq. Design performed using staad is as given below.
1. STAAD SPACE
INPUT FILE: wtp.STD
2. START JOB INFORMATION
3. ENGINEER DATE 01-OCT-09
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT METER KN
7. JOINT COORDINATES
8. 1 0 -2.1 0; 2 0 -3.1 0
9. MEMBER INCIDENCES
10. 1 1 2
11. DEFINE MATERIAL START
12. ISOTROPIC CONCRETE
13. E 2.17185E+007
14. POISSON 0.17
15. DENSITY 23.5616
16. ALPHA 1E-005
17. DAMP 0.05
18. END DEFINE MATERIAL
19. MEMBER PROPERTY AMERICAN
20. 1 PRIS YD 0.25 ZD 0.25
PROMAC STAC CONSULTANTS Project : 1x125 MW TPP IN SENDOU
ENGINEERING
Doc.No: PEIL-PED-DOC-PR1
INDUSTRIES Client : COMPAGNIE
LIMITED D’ELECTRICITE DU SENEGAL Subject: PIPE SUPPORT DETAILS
Sh: 5 of 6 Rev: R0
21. CONSTANTS
22. MATERIAL CONCRETE ALL
23. SUPPORTS
24. 2 FIXED
25. LOAD 1
26. SELFWEIGHT Y -1.5
27. JOINT LOAD
28. 1 FY -6
29. PERFORM ANALYSIS
STAAD SPACE -- PAGE NO. 2
P R O B L E M S T A T I S T I C S
-----------------------------------
NUMBER OF JOINTS/MEMBER+ELEMENTS/SUPPORTS = 2/ 1/ 1
============================================================================
C O L U M N N O. 1 D E S I G N R E S U L T S
2
Net SBC KN/m S 50.00
2
Grade of concrete N/mm fck 20
FOOTING DATA
Length along X-Direction m Lx 0.60
Length along Y-Direction m Ly 0.60
Thickness of Footing at col face m T 0.30
Thickness of Footing at end m t 0.30
Depth of footing below NGL m H 1.00
Depth of footing below FGL m H1 1.00
Depth of footing below Top of Pedestal m H2 1.00
WATER TABLE
(if water table does not
Water table below FGL m H3 exist enter value of H1 1.00
COL DATA
Column Dimension along X-Dir m lx 0.25
Column Dimension along Y-Dir m ly 0.25
REINF DATA
Clear Cover to Reinf 50
Reinf Along X ( For My ) : Asx
Diameter mm d input 12
Spacing mm s input 150
PAGE 1
STAC CONSULTANTS COMPAGNIE D'ELECTRICITE DU SENEGAL
PROMAC ENGINEERING INDUSTRIES LTD
PROJECT: 1X25 MW TPP AT SENEGAL
PIPE SUPPORT FOUNDATION
Against Uplift SAFE
no
TENSION CHECK tension
Input "K", as per Fig-6.14,of Teng in case of Tension 0.00
CALCULATIONS
Final Values Adopted for Ftg Design
Vertical load - Unfactored KN P 5.70
Moment about x-x KN-m Mx MX+Fy*H2+Mx,add 0.00
Moment about y-y KN-m My MY+Fx*H2+My,add 0.00
2
Footing area m A Lx*Ly 0.36
((A*t)+(((Lx*Ly)+(lx*ly))/2*(
Weight of Footing KN WF T-t)))*25 2.70
(A-(lx*ly))*(H1-
Weight of soil above Footing KN WS T)+((A+(lx*ly)/2*(T-t))*18 3.75
Col weight KN WC (lx*ly)*(H2-T)*25 1.09
Total load KN WT W F+W S+W C+P 13.24
Eccentricity along y-y = Mx / P m ey Mx/W T 0.00
Eccentricity along x-x = My / P m ex My/W T 0.00
Factors Reqd for Calculation of "K" Value
Factor ex / Lx 0.00
Factor ey / Ly 0.00
2
P/A KN/m PV WT / A 36.78
3
Z about x-x m ZXX (1/6)*(Lx*Ly*Ly) 0.04
3
Z about y-y m ZYY (1/6)*(Ly*Lx*Lx) 0.04
2
Mx/Zx KN/m PX Mx/Zx 0.00
2
My/Zy KN/m PY My/Zy 0.00
S*(1 for N and 1.25 for
2
SBC with overburden soil KN/m GS WL/SL)+(H*18) 68.00
Base pressure
2
Pmax (Pa) KN/m PA PV+PX+PY 36.78
2
Pmin (Pb) KN/m PB PV-PX-PY 36.78
2
(Pc) KN/m PC PV+PX-PY 36.78
2
(Pd) KN/m PD PV-PX+PY 36.78
2
Redistriduted Max Base pressure KN/m Predist NA
PAGE 2
STAC CONSULTANTS COMPAGNIE D'ELECTRICITE DU SENEGAL
PROMAC ENGINEERING INDUSTRIES LTD
PROJECT: 1X25 MW TPP AT SENEGAL
PIPE SUPPORT FOUNDATION
((PE-
MY PG)*0.5*LY*2LY/3)+((PG-
Moment at face of col without redistribution KN-m 0.29
Moment at face of col using redist pressure KN-m MYREDIST W (Predist
)*L -W *L /2)+(Pw*L *L /
dead)*LY*LY/2 NA
PAGE 3
STAC CONSULTANTS COMPAGNIE D'ELECTRICITE DU SENEGAL
PROMAC ENGINEERING INDUSTRIES LTD
PROJECT: 1X25 MW TPP AT SENEGAL
PIPE SUPPORT FOUNDATION
((PE-
2
Max base pr. At col face KN/m PG PF)*((W/2+w/2)/W))+PF 36.78
2
Avg pr. KN/m PAVG (PE+PG)/2 18.87
2
Base pr. At col face KN/m PE ((PA-PD)/W*(W/2+w/2))+PC 36.78
2
Avg pr. KN/m PAVG 18.87
2
Water Pressure at founding level KN/m Pw (H1-H3)*10 0.00
Cantilever length m LX Lx/2 - lx/2 0.18
((PE-
PG)*0.5*LX*2LX/3)+((PG-
W dead)*LX*LX/2)+(Pw*Lx*Lx/
Moment at face of col without redistribution KN-m MX 2) 0.29
Moment at face of col using redist pressure KN-m MXREDIST (Predist-W dead)*LX*LX/2 NA
PAGE 4
STAC CONSULTANTS COMPAGNIE D'ELECTRICITE DU SENEGAL
PROMAC ENGINEERING INDUSTRIES LTD
PROJECT: 1X25 MW TPP AT SENEGAL
PIPE SUPPORT FOUNDATION
Permissible Shear Stress (N/mm2) τc 0.3929461
(Ref Formula in Sp:16 p175 ) 7.5140342
β = 0.8 fck / 6.89 pt >= 1 β 7.5140342
Max Allowable Shear Stress τcmax 2.8
PAGE 5
STAC CONSULTANTS COMPAGNIE D'ELECTRICITE DU SENEGAL
PROMAC ENGINEERING INDUSTRIES LTD
PROJECT: 1X25 MW TPP AT SENEGAL
PIPE SUPPORT FOUNDATION
PAGE 6