Ultrasonic (Wall Thickness) Inspection Report

Inspection Details
Client INEOS Report No. BIS-DK-UT 1153
Project CS-2038891 Location SIRI
Contract No. TBC PO/Request No. 4501070170
Test Date 25.04.2022 Workpack No. RBI 2022
Part Description UT inspection of 1200-26-VG11 first stage Reinjection compressor
Drawing No. VE97027F Rev 4 Line No. 1200-26-VG11
P & ID Drawing No. N/A Location / System Level 1
Material Type Carbon Steel Material Thickness TBC
External Coating Painted Surface Temperature Ambient
Equipment, Technique & Application Method
Procedure No. SAL-INP-NDT-PRO-059: UT Thickness Measurement Ver No. 5
Technique No. T/EN/UT/01A - Spot Check Thickness Measurement Ver No. 5
Technique Std BS EN ISO 16809 Acceptance Criteria as per Client
Temp. Correction N/A Test Mode(s) N/A
Test Restrictions N/A
Manufacturer Model SAL ID Couplant
Flaw Detector Equipment
Olympus Epoch M600 20083 UCA 2
Calibration Block Type SAL ID
5-25mm Carbon Steel Stepwedge 20/21/01
Calibration Block Type
Reference Block Type SAL ID

Basic Transfer Scan


Crystal Size Frequency Timebase
Serial No. Type Angle (°) Sensitivity Correction Sensitivity
(mm) (MHz) Range (mm)
(db) (db) (db)
38390 TC 5/10 0 10 5 50

Control Checks
✘ Visual Angle Index ✘ Sig/Noise Ratio ✘ Vertical Linearity ✘ Pulsed Duration

By marking the equipment/probe check boxes you are confirming the checks have been carried out in accordance
with the applicable procedure appendix and that the results are satisfactory for all equipment and probes used.

Inspection Summary
Scope - Brief Summary of task
UT inspection was carried out on the first stage Reinjection compressor for corrosion monitoring

Result Summary - Overview of inspection findings


The UT inspection shows no significant corrosion spots

Restrictions - Elaborate on test restrictions


No restrictions

Technician (Print) Technician Signature Qualifications Date


Morgan Ehrlich Morgan Ehrlich PCN L2 25.04.2022
Client (Print) Client Signature Management Approval

UNCONTROLLED IF PRINTED

Inspection NDT SAL-INP-NDT-TEM-022 V 2 Application as from 21/12/2021


Applicable Procedure Ref Multiple UT Technical Procedues
Page 1 of 6
Ultrasonic (Wall Thickness) Inspection Report

Bilfinger UK Ltd, 4 Greenhole Place, Bridge of Don, Aberdeen, AB23 8EU | Tel: +44 1224 246100

UNCONTROLLED IF PRINTED

Inspection NDT SAL-INP-NDT-TEM-022 V 2 Application as from 21/12/2021


Applicable Procedure Ref Multiple UT Technical Procedues
Page 2 of 6
Ultrasonic (Wall Thickness) Inspection Report

UT Results Table
Client INEOS Report No. BIS-DK-UT 1153
Min Reading Location
Examination Point / Test Surface Nominal Fresh Thickness Min WT
EWL cat. TWL cat. X Y Comments
Feature ID Geometry Condition WT (mm) (mm) (mm) Datum
(mm) (mm)
R1 S G - - - 25 24.7
R2 S G - - - 22.8 22.5
N1 V G - - - 12.8 12.3
N2 V G - - - 18.8 18.4

Key to Acronyms

B = Bend P = Pipe Straight EXC = External Corrosion LAM = Laminations R = Restriction due to….
C = Cap R = Reducer IP = Internal Pitting NT = No Test Due to…
S = Tank Shell V = Vessel IC = Internal Corrosion
F = Flange T = Tee MII = Minor Isolated Inclusions
Surface Condition
G = GOOD F = FAIR P = POOR VP = VERY POOR
As or close to original Condition ≥90% Minor deterioration - approximately 75-90% Deterioration resulting in approximately 50- Significant deterioration resulting in <50% test
Coverage achievable test coverage achievable 75% test coverage achievable coverage achievable

UNCONTROLLED IF PRINTED

Inspection NDT SAL-INP-NDT-TEM-022 V 2 Application as from 21/12/2021


Applicable Procedure Ref Multiple UT Technical Procedues
Page 3 of 6
Ultrasonic (Wall Thickness) Inspection Report

Bilfinger UK Ltd, 4 Greenhole Place, Bridge of Don, Aberdeen, AB23 8EU | Tel: +44 1224 246100

UNCONTROLLED IF PRINTED

Inspection NDT SAL-INP-NDT-TEM-022 V 2 Application as from 21/12/2021


Applicable Procedure Ref Multiple UT Technical Procedues
Page 4 of 6
Ultrasonic (Wall Thickness) Inspection Report

Photograph Page
Client INEOS Report No. BIS-DK-UT 1153

Photo 1 - Stand-off view of VG11 Photo 2 - Close-up view

Photo 3 -Close-up view of the top nozzle Photo 4 - view of the bottom inside foundations

Photo 5 - Photo 6 -

UNCONTROLLED IF PRINTED

Inspection NDT SAL-INP-NDT-TEM-022 V 2 Application as from 21/12/2021


Applicable Procedure Ref Multiple UT Technical Procedues
Page 5 of 6
Ultrasonic (Wall Thickness) Inspection Report

Bilfinger UK Ltd, 4 Greenhole Place, Bridge of Don, Aberdeen, AB23 8EU | Tel: +44 1224 246100

UNCONTROLLED IF PRINTED

Inspection NDT SAL-INP-NDT-TEM-022 V 2 Application as from 21/12/2021


Applicable Procedure Ref Multiple UT Technical Procedues
Page 6 of 6