You are on page 1of 24

INSTALLATION 

GUIDE

SSAS SEAGUARD V4.14.01

NSEA - G

Revision: 1.1. Date 10-Mar-14 © StratumFive Ltd

Tel. +44 (0) 1273 462001 Email. support@stratumfive.com


SSAS V4 - SeaGuard Installation Guide V 1.0

CONTENTS
Introduction 3

Installation Steps 3

Identify Components And Required Tools 4

Determine A Suitable Mounting Location 5

Locate Antenna Box And Components 6

Safety 6

Install Interface Box 6

Alert Button Connections 7

Connect Alert Buttons 7

Interface Box Connections 8

Install IDP Transmission Terminal Inside New Antenna Box 9

Mount Antenna Box 9

Connect Antenna Cable To Antenna Box 10

Final Commissioning Checks 11

Connecting Power 11

Closing And Securing The Antenna Box 12

Appendices 13

Contact 13

System Wiring Diagram 14

Antenna Box Dimensions 15

Interface Box Dimensions 16

Maintenance And System Operation 17

Dry Dock Power Down Procedure 18

Test Procedure 19

Troubleshooting 20-21

IDP Transmission Terminal LED Sequence 21

Product Descriptions 22

Type Approval Certificate 23

2 Tel. +44 (0) 1273 462001 Email. support@stratumfive.com


SSAS V4 - SeaGuard Installation Guide V 1.0

INTRODUCTION
This Installation Guide is provided as a simple aid to installation and can be followed by any competent
member of ships staff or by an installation engineer. Please be careful to follow all stages in this guide.
(Further installation manuals can be downloaded from our document website – https://system.stratumfive.
com/documentation/) If during the installation there should be any doubt of the correct way to configure the
SSAS, please consult this Installation Manual for more detail or contact our support team for further advice.
Please pay careful attention to any item with IMPORTANT noted in this guide.

NSEA - G - SeaGuard SSAS


The StratumFive SSAS V4 Antenna Box comprises the following: IP rated and sealed polycarbonate box
with 2x 20mm IP rated glands together with Gortex breathing vent. The internal components comprise 2x 7
Ah 12 volt SLA batteries and float charging circuit (24vDC in) The upper level houses the IDP Transmission
terminal and DIN Rail connection bar for the connectivity of all connections to the antenna and tamper
alarm. The Interface Box consists of a Polycarbonate grey enclosure, DIN Rail terminal connectors and Test
Switch There are 2x Alert Buttons (N/C) and 1x 40m Alert Button Cable and 1x 20m Antenna Cable supplied.

INSTALLATION STEPS (IMPORTANT)

Step 1 - Ensure consignment contents match Packing List.


Step 2 - Record the IDP Transmission Terminal Serial Number. (IMPORTANT)
Step 3 - Install the Interface Box and Alert Buttons.
Step 4 - Mount Antenna on the Upper Deck or up the Mast.
Step 5 - Connect Power.
Step 6 - Submit Activation Form to StratumFive (via Reseller or directly from Shipping/Management Company).
Step 7 - Liaise with relevant office personnel to conduct test.

Tel. +44 (0) 1273 462001 Email. support@stratumfive.com 3


SSAS V4 - SeaGuard Installation Guide V 1.0

IDENTIFY COMPONENTS AND REQUIRED TOOLS

Product Components
V4 Antenna Box

IDP Transmission Terminal

Alert Buttons & Cables

Interface Box

Antenna Cable

Tools Required
Flat Head Screw Driver

Cross Head Screw Driver

Adjustable Spanner

6mm Socket Driver

Terminal Screw Driver

Multi-meter (low voltage)

DO NOT CONNECT POWER

4 Tel. +44 (0) 1273 462001 Email. support@stratumfive.com


SSAS V4 - SeaGuard Installation Guide V 1.0

DETERMINE A SUITABLE MOUNTING LOCATION


Before installing the SSAS, consider the important guidelines provided below for successful message
transmissions.

CAUTION It is very important for installers to install the terminals in a safe and secure way to avoid danger or
damage to persons or property.

Mount the terminal where it has a clear view of the sky/satellite. This means at the highest point on
the vessel where it has a clear view of the sky in all directions.

Make sure that the line of sight is clear of obstructions.

Mount the terminal on a flat, horizontal surface such that a change with rotation does not
cause obstructions.

The terminal is not to be installed in the direct line of the radar or less than 2m from other
radio equipment.

DO NOT CONNECT POWER

Tel. +44 (0) 1273 462001 Email. support@stratumfive.com 5


SSAS V4 - SeaGuard Installation Guide V 1.0

LOCATE ANTENNA BOX AND COMPONENTS

A B

C C

(A) Antenna - mounted above the bridge on (C) Alert Buttons - one installed on the bridge
the main mast or monkey island. and a second installed in a further location
(recommended in the masters’ cabin)
(B) Interface Box - installed in or around the
bridge area.

SAFETY
To protect the installer and the new equipment during installation we highly recommend that you follow the
following procedure:

Isolate power in from main distribution point Check power to ensure isolation

INSTALL INTERFACE BOX

Secure the interface box in an appropriate and discrete location, you will need to use fixings for this (which are
not supplied) Depending on material that you are intending to install to, this will require M4 size screws or bolts.
M4
You will note that you have to remove the lid of the
Interface Box and secure the base to a bulkhead or inside a
cupboard.

Provided are 4 cable glands (1x M20 and 3 x M16) the


installer must knock out the appropriate holes in the base
of the Interface Box and secure the cable glands prior to
routing the cables into the box.
Base gland knock outs
DO NOT CONNECT POWER

6 Tel. +44 (0) 1273 462001 Email. support@stratumfive.com


SSAS V4 - SeaGuard Installation Guide V 1.0

ALERT BUTTON CONNECTIONS


Use the terminal screw driver to secure the
Alert Button cable to the button contacts.

The Alert Button cable has a Brown and a Blue core,


ensure that one core is connected to terminal 1 and
the other is connected to terminal 2.

If you wish to connect more than one button to the


same alarm line as a daisy chain, please note these
must be connected in a series circuit. We advise
using a connector block for making the connection

between the two alarm lines.

If you have any questions regarding how this should


be undertaken please don’t hesitate to contact the
support team for advice, contact details on P. 13.

CONNECT ALERT BUTTONS

Install the Alert Buttons in a suitable


location; ensure they are discretely
positioned to prevent accidental
alert triggers.

Connect the required number of buttons


to the Interface Box DIN rail and securely
tighten all terminal connections.

IMPORTANT
NOTE: If More than one button per zone
is being connected; then you will need
to replace the wire jumpers with the
additional normally closed Alert Buttons.

DO NOT CONNECT POWER

Tel. +44 (0) 1273 462001 Email. support@stratumfive.com 7


SSAS V4 - SeaGuard Installation Guide V 1.0

INTERFACE BOX CONNECTIONS

IMPORTANT
The Test Switch Button Box has
a Green LED to indicate when
power has been connected to the
interface box and provides the
facility to test the SSAS locally,
Please see the Test Process on
P. 19 for more information
on testing.

Normally closed (N/C) alert buttons are required (x2 Supplied). Using the single button install per zone then
there will be no need to reconfigure the zone wiring, simply remove the first blue wire jumper.

Connect Antenna Cable as per the colour code detailed below, please confirm with diagram:

Connector Cable Colour


+VE Red
- VE Black
Alarm Line 1 Yellow
Alarm Line 2 Blue
Test Green
Mains Test White
TX Brown
RX Violet

DO NOT CONNECT POWER

8 Tel. +44 (0) 1273 462001 Email. support@stratumfive.com


SSAS V4 - SeaGuard Installation Guide V 1.0

INSTALL IDP TRANSMISSION TERMINAL INSIDE NEW ANTENNA BOX


Install and secure the IDP Transmission Terminal inside the Antenna Box using the screws provided, ensure
the connector is securely in place to the underside of the terminal.

IMPORTANT
NOTE: The IDP Transmission Terminal serial
number for activation; the serial number should
look similar to this: 01006853SKY5356

DO NOT cover the Antenna in any way

MOUNT ANTENNA BOX

There are four anchor points at the corners of the


antenna box, we recommend using stud metal ends
(these are not provided) to mount the antenna box
up the mast or on the monkey island.

NOTE: Make reference to the Antenna Box Line


Drawing and dimensions on P. 15 No if required.

IMPORTANT
DO NOT cover or paint the Antenna Box

DO NOT CONNECT POWER

Tel. +44 (0) 1273 462001 Email. support@stratumfive.com 9


SSAS V4 - SeaGuard Installation Guide V 1.0

CONNECT ANTENNA CABLE TO ANTENNA BOX


Securely route the Antenna
Cable To the Antenna Box, use
the cable glands provided and
ensure that they are tightened
down on to the cable. (Note
that the Antenna Cable has
ferrules on each end to allow
for easy installation).

Antenna Box Wiring


Please ensure that on an NSEA-G installation the Antenna cable power cores (Red and Black) are connected
to Fuse 1 and ground. The table below lists which coloured core is wired into the connector, Please See
Wiring Diagram for additional assistance.

Connector Cable Colour


Fuse 1 Red
GND Black
Test Green
Mains Test White
TX Brown
RX Violet
Alarm Line 1 Yellow
Alarm Line 2 Blue

NOTE: Please ensure that Orange and Blue wires are removed from Alarm Line 1 and Alarm Line 2
connectors that would have been installed at manufacture. Only the cables connected to the Grey
connectors DIN rail should be the Antenna cable (see system diagram).

DO NOT CONNECT POWER

10 Tel. +44 (0) 1273 462001 Email. support@stratumfive.com


SSAS V4 - SeaGuard Installation Guide V 1.0

FINAL COMMISSIONING CHECKS

Before applying power check


the following:

Continuity of the button contacts


using a multi-meter.

All DIN Rail connector blocks are


tight and secure using a terminal
screwdriver.

Ensure the fuses have not blown,


however, please do not push
into place.

The next step is to apply power on


the application.

CONNECTING POWER

The power is connected in two stages


first is to apply power (24v DC) to
the interface board and check then
secondly to the antenna box. Please
check that all cables are secure and
all alert buttons have been connected
before applying power.

Ensure the Fuse in the interface box


is pushed into the closed position
completing the circuit.

Switch on power to the interface box.

Check that the Green LED lights up


in the interface box.

Fuse 1 in the antenna is next to be pushed into place; you may notice the LEDs on the charging
circuit light up.

Close Fuse 2 in the antenna box; The SSAS is now operational and the LED on the IDP Terminal
comes on momentarily when connected (this will go out again during normal operation).

Tel. +44 (0) 1273 462001 Email. support@stratumfive.com 11


SSAS V4 - SeaGuard Installation Guide V 1.0

CLOSING AND SECURING THE ANTENNA BOX


To secure the antenna box, please use the antenna
box diagram for assistance, the 4 corner holes to
fasten the antenna to the to the upper deck or mast.

When closing the Antenna Box Lid Check the


tamper switch is pushed down. Please see the
following image for how the arm to the tamper
switch should be positioned for effective use.

Before closing the antenna box please check the


following:

Ensure all cables and cable glands are secure.

Using a multi meter confirm continuity on


Alarm Lines 1 and 2 with GND.

The fuses are intact and pushed into position.

Using a crosshead screwdriver, secure the 4x corner screws. Be careful not to over tighten the Screws or round
out the heads.

Using a crosshead screwdriver, secure the 4x corner


screws. Be careful not to over tighten the Screws or
round out the heads.

IMPORTANT
Ensure that there are no obstructions to the antenna
box that houses the IDP Transmission Terminal,
as this will prevent messages from being sent or
received by the Transmission terminal. Please refer
to the “Determine Suitable Mounting Location”
section for advice.

12 Tel. +44 (0) 1273 462001 Email. support@stratumfive.com


SSAS V4 - SeaGuard Installation Guide V 1.0

APPENDICES

Contact 13

System Wiring Diagram 14

Antenna Box Dimensions 15

Interface Box Dimensions 16

Maintenance 17

Dry Dock Power Down Procedure 18

Test Procedure 19

Troubleshooting 20-21

Product Descriptions 22

Type Approval Certificate 23

CONTACT OUR SUPPORT TEAM


Email: support@stratumfive.com

Tel: +44 (0) 1273 462001

Address: Stratum Five Ltd

Unit 5 Riverside Business Centre

Brighton Road

Shoreham By Sea

West Sussex

BN43 6RE

United Kingdom

Tel. +44 (0) 1273 462001 Email. support@stratumfive.com 13


SSAS V4 - SeaGuard Installation Guide V 1.0

SYSTEM WIRING DIAGRAM

Antenna Cable

14 Tel. +44 (0) 1273 462001 Email. support@stratumfive.com


SSAS V4 - SeaGuard Installation Guide V 1.0

ANTENNA BOX DIMENSIONS

Tel. +44 (0) 1273 462001 Email. support@stratumfive.com 15


SSAS V4 - SeaGuard Installation Guide V 1.0

INTERFACE BOX DIMENSIONS

16 Tel. +44 (0) 1273 462001 Email. support@stratumfive.com


SSAS V4 - SeaGuard Installation Guide V 1.0

MAINTENANCE AND SYSTEM OPERATION


The SSAS is designed to operate autonomously without user interaction once the installation has been
completed whilst the vessel is underway with mains power. Whilst on batteries alone the reporting will last
for up to 2 weeks, normal operation will resume when mains power is reconnected. When the vessel is in dry
dock please follow dry dock and power procedure to maintain battery life and to avoid false alerts detailed
on P. 18.

The SSAS will send a minimum of one position report per day. When an alert zone is initiated; a repeated
alert message will be sent every 15 minutes. To initialise an alert simply press and hold the alert button for
2 seconds. A reset sent from within OTiS is required to reset the alerts.

We recommend that a SSAS test is performed every year to ensure the system is in good working order
and that the correct contacts are notified, the test procedure is defined in a subsequent section of this
guide on P. 19.

To add a security contact, please perform the following from within OTiS:

Navigate to the Alerts Tab, which is displayed below the Map.

In the Data Grid, click the vessel name of the vessel you wish to update.

Upon clicking, the row will be highlighted with a darker grey, and the contacts panel will be active.

Here you will be able to: add using the Add Contact Button, delete by clicking the trashcan icon, and
finally enable or disable by checking or unchecking the tick box.

The changes you have made will be automatically saved.

The back up batteries included in the SSAS are located in the lower levels of the antenna box and have a life
expectancy of up to 3 years. There are 8 bolts to unscrew in order to access the battery compartment. To
replace the batteries simply pull the connectors to the batteries, affix the new batteries in place, and finally
reattach the upper level of the antenna box chassis. Once complete dispose of used batteries appropriately.

Tel. +44 (0) 1273 462001 Email. support@stratumfive.com 17


SSAS V4 - SeaGuard Installation Guide V 1.0

DRY DOCK POWER DOWN PROCEDURE


IMPORTANT
When the vessel goes into Dry Dock or is likely to have ships power removed from the Antenna Box for
a long period the fuses to the on the Din Rail should be disconnected inside of the Antenna Box as per
following image. This will preserve the life of the internal back up batteries.

To do this perform the following


simple procedure:

Remove the outer base plate


bracket.

Detach the lid of the Antenna


Box by un-screwing the four
corner bolts.

Disconnect the Fuses


1 and 2.

To maintain integrity of the SSAS please close the Antenna Box. Ensure that Ships Power is removed prior to
undertaking the above procedure. You can check this by observing the Red LED’s on the PCB are not lit.

Remember to re-commission the system when coming out of Dry Dock.

18 Tel. +44 (0) 1273 462001 Email. support@stratumfive.com


SSAS V4 - SeaGuard Installation Guide V 1.0

TEST PROCEDURE
In order to Test the SSAS you have two options:

Hardware one time only test alert

Open the Interface Box.

Press and hold the Test Button and the Red LED will be extinguished.

Whilst holding the test button, press the alert buttons.

A one time Supervisor Test alert will be sent with no need to reset the SSAS.

Software test alert

Schedule a Time to test with the master or crew.

From within OTiS click the begin test link under the alert tab prior to the test being carried out.

The Master or Crew presses the Alert at the scheduled time.

When the alert is received, you will need to reset the alert from OTiS using the Reset Link under
the Alert Tab.

The OTiS test mode will be active for 90 minutes or until an alert is received.

To reset the SSAS you or the CSO will need to login to OTiS, navigate to the Alerts Tab, and Click the Reset
link for the vessel in alert.

Our standalone SSAS is designed, to be easily installed as all alert contacts are managed online.

Tel. +44 (0) 1273 462001 Email. support@stratumfive.com 19


SSAS V4 - SeaGuard Installation Guide V 1.0

TROUBLESHOOTING

No Reports being received:


Check voltage on pin 3 and 4 and that +ve and –ve are not reversed on the connector leading
to IDP Transmission Terminal.

Do LEDs light up.

Ensure all terminal blocks are tight and all wire jumpers are connected as per the detailed
wiring diagrams in the installation guide.

Please follow the LED Sequence Table below for what action to take with regards to the IDP
transmission Terminal Flash sequences.

Check that Fuses are not blown (replace if required).

Confirm 24v DC input on the connector blocks.

Refer to “DETERMINE A SUITABLE MOUNTING LOCATION” section on P. 05 to rectify any Line Of


Sight issues that may be affecting the reports.

Ensure that no outer bracket is obstructing the signal from the IDP Transmission Terminal.

The SSAS is designed to operate out in open water, if the vessel is in port we cannot guarantee
position reports as a super structure may be blocking the signal.

Alerts not being received:


Confirm the correct Alert Buttons are being used.

Buttons should be wired in series and not in parallel.

Confirm that the Alert Buttons break the circuit when pressed.

Ensure the alert zone wires that wrap around the DIN rail in the antenna box, which are connected
during manufacture are disconnected upon installation, as described in the “CONNECT ANTENNA
CABLE TO INTERFACE BOX” section on P. 10.

Email notifications not being received.

Check there are no type errors for the alert contact email address within OTiS.

Please ensure that your spam filter is not blocking our email address noreply@stratumfive.com.

If there are still issues in receiving the Email please contact StratumFive Support.

SMS notifications not being received.

Check there are no type errors for the alert contact email address within OTiS.

The format of the contact number should be +(Country Code) (Telephone Number)

If there are still issues in receiving the SMS please contact StratumFive Support.

20 Tel. +44 (0) 1273 462001 Email. support@stratumfive.com


SSAS V4 - SeaGuard Installation Guide V 1.0

TROUBLESHOOTING

High number of Alert Messages:

Check normally closed alert buttons are being used.

Perform continuity check on Alert Zones and ensure no line breaks whilst buttons are not
being pressed.

Ensure there are no loose contacts on the alarm lines or DIN rail.

Check the tamper switch arm is pushed down when antenna box lid is in place.

IDP TRANSMISSION TERMINAL LED SEQUENCES

Reason LED Sequence Action


Startup - DTE Connected,
Normal flash for 5 seconds No action required
no error
Startup - DTE Disconnected,
Normal flash for 10 seconds No action required
no error
Startup - DTE Connected,
Fast flash for 10 seconds Power cycle SSAS
Boot ERROR
Startup - DTE Connected, Normal Flash for 5 seconds,
Contact StratumFive Support
Base ERROR Fast flash for 10 seconds
Startup - DTE Disconnected,
Fast flash for 10 seconds Power cycle SSAS
Boot ERROR
Startup - DTE Disconnected,
Fast flash for 10 seconds Contact StratumFive Support
Base ERROR
Waiting for GPS fix 3 normal flashes every 30 Check Line Of Sight;
seconds Wait 10 Minutes
2 normal flashes every 30 Check Line Of Sight and wait
Registration in progress
seconds for next frame
Connection online 1 normal flash every 30 seconds No action required
4 normal flashes every 30
Connection offline Power cycle SSAS
seconds

Tel. +44 (0) 1273 462001 Email. support@stratumfive.com 21


SSAS V4 - SeaGuard Installation Guide V 1.0

PRODUCT DESCRIPTIONS

SSAS - NSEA - G - IDP - SEAGUARD V4


Complete ship security alert system with INMARSAT ISATDATAPRO short burst data terminal, using
existing 20m 8-core antenna cabling and 2 alert buttons with 2 core alert cables, Tamper alarm, installation
and activation instructions.

SSAS - NSEA - P - IDP - SEAGUARD V4


Complete ship security alert system with INMARSAT ISATDATAPRO short burst data terminal, Tamper
alarm. To be connected using pre-existing SSAS cabling and alert buttons and alert cabling, installation
and activation instructions.

SSAS - NSEA - L - IDP - LITE SEAGUARD V4


Complete ship security alert system with INMARSAT ISATDATAPRO short burst data terminal, 20m 8-core
antenna cabling and 2 alert buttons with 2 core alert cables, installation and activation instructions.

SSAS - OSEA - U - IDP - SEAGUARD V4


Complete ship security alert system with INMARSAT ISATDATAPRO short burst data terminal and 2 alert
buttons, Tamper alarm. To be connected using pre-existing SSAS cabling, installation and activation
instructions.

22 Tel. +44 (0) 1273 462001 Email. support@stratumfive.com


SSAS V4 - SeaGuard Installation Guide V 1.0

TYPE APPROVAL CERTIFICATE

Tel. +44 (0) 1273 462001 Email. support@stratumfive.com 23


Tel. +44 (0) 1273 462001 Email. support@stratumfive.com

You might also like