From: Engineering Date: 2 APRIL 1998 Subject: SIB 2 REV. A & REV. B Configuration IGT SAS 2.82 Protocol (Version 1.16AB) Reference: Replaces 97019; ECO 4597 Overview This EIB describes installation and configuration procedures Plug the twenty-pin connector from SIS board INPUT location for the sigma® SIB 2 player tracking interface board. Software ver- on to SIB 2 board location CN1. If not equipped with a SIS board, this sion 1.16AB supports basic accounting and player tracking data col- connector is tied back to the wire harness near the power control lection for IGT SAS 2.82 player tracking system protocol. panel. PLUS models only: install serial I/F harness (PN 130593) Before installing the SIB 2 board. Verify the following compo- between SIB 2 board location CN2 and main CPU PCB location CN15 nents are present: software EPROM SIB 2 1.16AB installed in loca- (see Special Considerations earlier in this EIB). Verify DIP 2 post-8 tion U3; jumper across pins at location JP3 (TTL Interface Only); jumper on the main CPU PCB is set to the ON position. across pins labeled T (TTL Interface) or 4 (RS232 Interface) at TTL Interface: Connect the IGT SAS system to SIB 2 location location JP1. CN4. CN4 pin-6 is the serial data connection (SIB Tx) from the SIB 2 board to the IGT SAS system. CN4 pin-5 is the serial data connec- tion (SIB Rx) from the IGT SAS system to the SIB 2 board. CN4 pin- Special Considerations 9 is +5 VDC out. CN4 pin-12 is the ground connection. Sigma® PLUSsss model machines with main software version RS232 Interface: Connect the IGT SAS system to SIB 2 loca- 65 or later support serial data communication between the main tion CN4. CN4 pin-2 is the serial data connection (SIB Tx) from the CPU PCB and the SIB 2 board. An additional serial I/F harness (PN SIB 2 board to the IGT SAS system. CN4 pin-4 is the serial data 130593) connects the SIB 2 board to the main CPU PCB. The SIB 2 connection (SIB Rx) from the IGT SAS system to the SIB 2 board. board automatically reads and reports meter values when machine CN4 pin-12 is the ground connection. power is turned on. Setting SIB 2 modes IS NOT required. If required, power-off isolated door open signals are available at SIB 2 location CN5 ( SIB 2 PCB REV. B; verify signal in at location Accessing Modes CN1 with machine wiring diagram; use a MTA style connector). CN5 PLUS models: Machines with software version 65 or later do pin-1 is the common ground. CN5 pin-2 is the isolated main door not require setting the following SIB 2 modes (installation is com- switch signal. CN5 pin-3 is the isolated DBV (bill acceptor) door sig- plete). nal. Other models: Follow the procedures below to set denomi- SIB 2 PCB versions prior to revision B require splicing (re- nation/hard meter operation modes (must match machine settings) move wire from plug and use a butt connector) into the wires at SIB 2 and synchronize the machine's credit meter value with the SIB 2 value. location CN1 (verify signal in with a machine wire diagram). CN1 pin- Turn on machine power. Set the C post on the DIP switch at 18 is the isolated main door signal. CN1 pin-19 is the isolated DBV location SW2 to the OPEN (up) position to enable mode options con- (bill acceptor) door signal. CN1 pin-10 is the common ground. figuration. The LED decimal point changes from continuous illumina- tion to flashing, indicating the SIB 2 is ready for optioning. Turn the NOTE: Main and DBV (bill acceptor) door switches are con- rotary switch at location SW3 to access the desired mode (see table figured normally open. To invert these signals reposition below). Press the push button at location SW1. The LED displays the switch terminal lugs to the normally closed position. Access current mode option value and the decimal point flashes faster. to the DBV (bill acceptor) switch requires removing the bill acceptor assembly. Rotary Switch SIB 2 Modes Position 0 Not used. Installing the SIB 2 Board The SIB 2 board mounts on 1 Change denomination. the power control panel. If equipped, 2 Not used. remove the SIS board. Use a pair of 3 Not used. pliers to squeeze the tip of a plastic 4 Change hard meter operation. mounting standoff and gently pull up 5 Not used. the corner of the board. Repeat for each standoff. Install the SIB 2 board 6 Syncronize machine credit meter value with onto these standoffs. Use adhesive SIB 2. standoffs to install the SIB 2 board if a SIS board is not present. 7-F Not used.
Set Denomination Mode Option Synchronize Credit Meter Value Access denomination mode. The current denomination mode Access synchronize credit meter mode. Press the push but- option displays. Turn the rotary switch to select the desired denomi- ton at location SW1. Turn off, then on machine power twice. Set post nation mode option (see table below). The LED displays the changed C of the DIP switch (SW2) to the CLOSED (down) position. rotary switch position/mode option setting and the rapidly flashing dot is replaced with a slow flash. Press the push button at location SW1 to save the setting. Set post C of the DIP switch (SW2) to the CLOSED (down) position. Verify Mode Settings Turn the rotary switch at SIB 2 PCB location SW3 to the de- Rotary Rotary sired mode. Set the C post on the DIP switch at SIB 2 PCB location Switch Denomination Switch Denomination SW2 to the OPEN (up) position. Press the push button at board Position Position location SW1. The current setting for the selected mode displays. 0 1¢ 8 $10 WARNING: Inadvertently pressing this button more than 1 5¢ 9 $20 once causes the selected mode option to change (indicated 2 10¢ A $25 when the rapidly flashing dot on the LED display is replaced 3 25¢ B $50 with a slow flash). The mode option must be reset. 4 50¢ C $100 Return post C of the DIP switch (SW2) to the CLOSED (down) 5 $1 D $500 position. Repeat for desired modes. 6 $2 E $1000 7 $5 F No t Use d
Set Hard Meter Mode Option
Access hard meter operation mode. The current hard meter operation mode option displays. Turn the rotary switch to select the desired hard meter operation mode option (see table below). The LED displays the changed rotary switch position/ mode option setting and the rapidly flashing dot is replaced with a slow flash. Press the push button at location SW1 to save the setting. Set post C of the DIP switch (SW2) to the CLOSED (down) position. NOTE: NJ IN = coins bet + credit bet (total coin-in); NJ OUT= coins played + credits bet from wins (total coin-out).
Rotary Switch Hard Meter Operation
Position (Left to Right, Top to Bottom) NJNoBills: Meter 1 = NJ IN; Meter 2 = NJ OUT; Meter 3 = 0 Jackpot; Meter 4 = Coin Drop (does not increment for accepted bills); Meter 5 = Games Played. New Jersey: Meter 1 = NJ IN; Meter 2 = NJ OUT; Meter 3 1 = Jackpot; Meter 4 = Total Drop (also increments for accepted bills); Meter 5 = Games Played. Bet/Win: Meter 1 = Bet; Meter 2 = Won; Meter 3 = Jackpot; 2 Meter 4 = Coin Drop (does not increment for accepted bills); Meter 5 = Games Played. Credit: Meter 1 = Credit up; Meter 2 = Credit Down; Meter 3 3 = Bet; meter 4 = Won; Meter 5 = Games Played. Drop: Meter 1 = NJ IN; Meter 2 = Coin Drop (does not 4 increment for accepted bills); Meter 3 = NJ OUT; Meter 4 = Jackpot; Meter 5 = Games Played.