SiE12-411 Wiring Diagrams

2. Wiring Diagrams
2.1 Indoor Units
2.1.1 Wall Mounted Type
FTKE25/35BVM, FTK(X)E25/35BVMA
FTK(X)S20CVMB(9), FTK(X)S25/35CVMB(9)(8), ATXS20/25/35CVMB(9), FTXS25/35BVMA

PCB3 S36 S35 PCB1 H1 1


X1M 2
INTELLIGENT- Fu →
EYE SENSOR 3.15A BLK 1 3
WHT 2 outdoor
H2
RED 3
PCB2 S27 S26 ( TERMINAL FOR
CENTRALIZED CONTROL ) C70
GRN/
YLW
FIELD WIRING.
H3
LED1 LED2 LED3 TRANSMISSION
S21 CIRCUIT
H1P H2P H3P S1 CAUTION
S1W S7
NOTE THAT OPERATION WILL
RESTART AUTOMATICALLY IF
SIGNAL THE MAIN POWER SUPPLY IS
RECEIVER t° TURNED OFF AND THEN BACK
M ON AGAIN.
S32 S6 1~
R1T t°
140°C
t° M1F H1P~H3P : PILOT LAMP
M1F : FAN MOTOR
R2T M
indoor M1S : SWING MOTOR
M1S PCB1~PCB3 : PRINTED CIRCUIT BOARD
INFRARED
REMOTE R1T~R2T : THERMISTOR
CONTROL S1~S36 : CONNECTOR
: PROTECTIVE EARTH
C70 : RUNNING CAPACITOR S1W : OPERATION SWITCH
Fu : FUSE X1M : TERMINAL STRIP

3D033599E

FTK(X)S50BVMB, FTXS50BVMA, ATXS50CVMB

FIELD WIRING.
PCB3 S27 S26 PCB1
H1 1
~ ~
RECTIFIER Fu X1M 2
3.15A BLK 1
H2 3
t° WHT 2 OUTDOOR

RED 3
R1T GRN/ CAUTION
TRANSMISSION H3
S38 YLW
CIRCUIT NOTE THAT OPERATION WILL
FG RESTART AUTOMATICALLY IF
PCB4 THE MAIN POWER SUPPLY IS
S37 TURNED OFF AND THEN BACK
S21 7 S1 ON AGAIN.
RED
LED1 LED2 LED3
FG : FRAME GROUND
H2P H3P BLU
H1P
BRN M Fu : FUSE
ORG H1~ H3 : HARNESS
1 WHT
PCB5 S36 S35 M1F H1P~ H3P : PILOT LAMP
INTELLIGENT EYE S28 S32 1 S6 5 1 S8 6 M1F : FAN MOTOR
SENSOR M1S, M2S : SWING MOTOR
PCB1~ PCB5 : PRINTED CIRCUIT BOARD
ORG

ORG
RED

BRN
RED
YLW

YLW
PNK

PNK
BLU

BLU

PCB2 t° R1T, R2T : THERMISTOR


INDOOR
SIGNAL S29 S1~ S38 : CONNECTOR
R2T
RECEIVER M S1W : OPERATION SWITCH
M
INFRARED S1W X1M : TERMINAL STRIP
REMOTE M1S M2S : PROTECTIVE EARTH
CONTROL
3D038065D