Measurement

Time Temp Cooling water


Data
Test Start Set Temperatur temperatur inlettemperatur outlet t1
Test Finsih t0 tin tout Δt1,2
10:19 45 27 28 39.3
A
10:39 45 27 28 0.2
10:40 60 27 28 54
B
11:00 60 27 28 0.8
11:01 75 27 28 68.4
C
11:21 75 27 28 1.1
11:22 80 27 28 82.9
D
11:42 80 27 28 1.5

DATA B DATA C DATA D Data A


DELTA TR 0.7166666667 DELTA TR 1.133333333 DELTA TR 1.53333333 DELTA TR
Delta A 0.784045584 Delta A 0.9671111111 Delta A 0.75720165 Delta A
Delta B 1.203849519 Delta B 1.27251462 Delta B 1.28278867 Delta B

2.5913371 1.85982906 4.19373219

t1 t2
Set
Data Time t in t out
Temp. Δt1,2

10.19 45 27 28 39.3 39.1


A
10.39 45 27 28 0.2

10.40 60 27 28 54 53.2
B
11.00 60 27 28 0.8

11.01 75 27 28 68.4 67.3


C
11.21 75 27 28 1.1
11.22 90 27 28 82.9 81.4
D
11.42 90 27 28 1.5
t2 t3 t4 t5 t6
Δt2,3 Δt3,4
39.1 38.8 38.5 34.2 33.8
0.3 0.3 4.3 5.4
53.2 52.3 51.7 42.2 41.4
0.9 0.6 9.5
67.3 66.1 64.8 50.8 49.4
1.2 1.3 14 16.3
81.4 79.7 78.1 59.5 57.8
1.7 1.6 18.6 21.9

Data A
0.316667

t3 t4 t5 t6 t7 t8 t9 t10
Δt a Δt b
Δt2,3 Δt3,4 Δt7,8 Δt8,9 Δt9,10

38.8 38.5 34.2 33.8 28.4 28.1 27.7 27.3


1.00 1.20
0.3 0.3 0.3 0.4 0.4

52.4 51.7 42.2 41.4 30.6 29.9 29.2 28.6


1.40 3.00
0.8 0.7 0.7 0.7 0.6

66.1 64.8 50.8 49.4 33.1 32 31 29.9


2.50 4.00
1.2 1.3 1.1 1 1.1
79.7 78.1 59.5 57.8 35.9 34.4 33 31.5
3.00 4.50
1.7 1.6 1.5 1.4 1.5

λ vs. Set
Temp.
40
35
30
Set
λ 25
Temp.
45.00 33.78 20
λ

60.00 9.56 15
75.00 16.12
21.81 10
90.00
5
0
0 10 20 30 40 50 60 70 80
Set
Temp.
t7 t8 t9 t10
Δt7,8 Δt8,9 Δt9,10
28.4 28.1 27.7 27.3
0.3 0.4 0.4
30.6 29.9 29.2 28.6
0.7 0.7 0.6
33.1 32 31 29.9
1.1 1 1.1
35.9 35.4 33 31.5
0.5 2.4 1.5

Δt R λa λb λ

0.32 6.76 11.26 33.78

0.72 10.92 10.19 9.56

1.13 9.67 12.09 16.12


1.53 10.90 14.54 21.81

Average 20.31

s. Set
mp.

50 60 70 80 90 100
Set
emp.