You are on page 1of 8

PRESSURE DROP LIMITATIONS (bar) METAL SEAT

TIGHTNESS CLASS IV

Table 1 Actuator Flow to open Flow to close


Open on air failure Close on air failure Open on air Close on air failure
Schema "A" Schema "C" failure Schema Schema "D"
Nominal Flow coefficient "B"
Dia Trim Supply Supply Supply Supply
inches reduction ON-OFF
1.4b 2.1b 3b 2.1b 3b 1.2b 1.4b
(mm)
Flow to Flow to Range Range Range Range Range Range 0.2 - 1 Range Max Max
NR NR
open close 80° 60° 0.2 - 1 0.2 - 1 0.2 - 1 0.7 - 1.9 1.4 - 2.8 ∆po ∆Pf 0.2 - 1 Range ∆Pf
S100 18 21 1 36 50 (1) - 50 - 50 50 50 1.4 100
N100 16 18 1 50 - - 50 - 50 50 50 1.4 100
1" (25)
R 70 11 12 1 65 - - 65 - 50 65 65 1.4 100
R 40 6 7 1 100 - - 100 - 50 100 100 1.4 100
S100 44 48 1 10 46 50(2) 23 50 19 34 34 2.1 100
N100 34 40 1 15 50 - 33 50 26 50 50 2.1 100
1" 1/2 (40)
R 70 24 28 1 21 65 - 47 65 26 65 65 2.1 100
R 40 14 16 1 29 100 - 50 100 26 100 100 2.1 100
S100 78 74 1 6 27 46 13 32 10 20 20 3 74
N100 53 55 1 8.5 38 60 19 46 15 28 28 3 100
2" (50)
R 70 37 39 1 12 55 94 28 66 15 40 40 3 100
R 40 21 22 1 17 77 100 39 93 15 57 57 3 100
S100 238 216 2 8.5 39 66 19 46 12 29 29 3 100
N100 159 155 2 12 55 90 28 67 22 41 41 3 100
3" (80)
R 70 111 110 2 17 79 100 40 95 22 50 50 3 100
R 40 64 62 2 24 100 100 56 100 22 50 50 3 50
S100 395 364 2 5 23 40 12 28 7 17 17 3 65
N100 255 277 2 7.5 33 58 17 41 13 25 25 3 90
4" (100)
R 70 179 195 2 11 48 83 24 58 13 36 36 3 100
R 40 102 110 2 15 67 100 34 82 13 50 50 3 100
S100 935 780 3 6.4 29 49 14 35 8.5 21 21 3 78
N100 560 597 3 9.1 41 70 21 50 16 30 30 3 100
6" (150)
R 70 392 420 3 13 59 100 26 71 16 43 43 3 100
R 40 224 240 3 18 82 100 41 100 16 60 60 3 100
SI00 1500 1100 3 3.8 17 29 8.6 20 5 8.4 8.4 3 46
8" (200) N100 930 890 3 5.4 24 42 12 29 10 12 12 3 66
R 75 700 670 3 7.2 32 56 16 39 10 16 16 3 88
S100 2180 1725 3 1.5 7.1 12 3.6 8.5 2 5 5.3 3 19
10" (250) N100 1740 1425 3 2.2 10 17 5.1 12 4 7 7.6 3 28
R 75 1100 1070 3 2.9 13 23 6.8 16 4 10 10 3 37
S100 3200 2440 3 1.1 5 8.7 2.5 6.1 1.4 3.5 3.8 3 13
12" (300) N100 2020 1980 3 1.6 7.2 12 3.6 8.7 3 5 5.4 3 19
R 75 1510 1490 3 2.1 9.6 16 4.8 11 3 7 7.1 3 26

* Also available without positioner (1’’à 2’’∆Po = ½ ∆Pf).


NOTE 1 : Pressure are also limited by the rating of valves and connections.
NOTE 2 : ∆P are only given for a quick valve sizing.
(1) Max supply pressure : 1.7 bar.
(2) Max supply pressure : 2.4 bar.
PRESSURE DROP LIMITATIONS (bar) PTFE SOFT SEAT
TIGHTNESS CLASS VI

Table 2 Actuator Flow to open Flow to close


Open on air failure Close on air failure Open on air Close on air failure
Schema "A" Schema "C" failure Schema Schema "D"
Nominal Flow coefficient "B"
Dia Trim Supply Supply Supply Supply
inches reduction ON-OFF
1.4b 2.1b 3b 2.1b 3b 1.2b 1.4b
(mm)
Flow to Flow to Range Range Range Range Range Range 0.2 - 1 Range Max Max
NR NR
open close 80° 60° 0.2 - 1 0.2 - 1 0.2 - 1 0.7 - 1.9 1.4 - 2.8 ∆po ∆Pf 0.2 - 1 Range ∆Pf
S100 10.5 12 1 18 50(1) - 50 - 20 50 50 1.4 50
1" (25) N 100 10 11 1 26 - - 50 - 20 50 50 1.4 50
R 70 6 7 1 50 - - 50 - 20 50 50 1.4 50
S100 37 41 1 5.2 41 50(2) 19 50 19 35 35 2.1 50
1 " 1/2 N100 32 38 1 7.4 50 27 50 26 50 50 2.1 50
(40) R 70 24 28 1 10 50 - 38 50 26 50 50 2.1 50
R 40 14 16 1 15 50 - 50 50 26 50 50 2.1 50
S100 70 67 1 3 24 46 11 30 10 20 20 3 50
N100 48 50 1 4.3 34 50 15 42 15 28 28 3 50
2" (50)
R 70 37 39 1 6.1 49 50 21 50 15 41 41 3 50
R 40 21 22 1 8.6 50 50 31 50 15 50 50 3 50
S100 238 216 2 4.3 35 50 15 43 12 29 29 3 50
N100 159 155 2 6.2 49 50 22 50 20 41 41 3 50
3" (80)
R 70 111 110 2 8.6 50 50 32 50 20 50 50 3 50
R 40 64 62 2 12 50 50 44 50 20 50 50 3 50
S100 395 364 2 2.7 22 41 9.5 26 7 17 17 3 50
N100 255 277 2 3.8 30 50 14 37 13 25 25 3 50
4" (100)
R 70 179 195 2 5.4 43 50 19 50 13 36 36 3 50
R 40 102 110 2 7.6 50 50 27 50 13 50 50 3 50
S100 935 780 3 3.2 26 50 12 32 8.5 22 22 3 50
N100 560 597 3 4.6 37 50 17 45 16 30 30 3 50
6" (150)
R 70 392 420 3 6.6 50 50 24 50 16 43 43 3 50
R 40 224 240 3 9.2 50 50 33 50 16 50 50 3 50
S100 1500 1100 3 1.9 15 29 7 19 5 8.4 8.4 3 46
8" (200) N100 930 890 3 2.7 22 42 10 27 10 12 12 3 50
R 75 700 670 3 3.6 29 50 13 36 10 16 16 3 50
S100 2180 1725 3 0.8 5.6 12 2.9 7.7 2 5 5.3 3 19
10" (250) N100 1740 1425 3 1.1 8 17 4.1 11 4 7 7.6 3 28
R 75 1100 1070 3 1.5 11 23 5.5 15 4 10 10 3 37
S100 3200 2440 3 0.6 4.6 8.7 2 5.6 1.4 3.5 3.8 3 13
12" (300) N100 2020 1980 3 0.8 6.5 12 2.9 8 3 5 5.4 3 19
R 75 1510 1490 3 1 8.6 16 3.8 10 3 7 7.1 3 26

See table 3 for PTFE limitations VS temperature


* Also available without positioner (1’’à 2’’∆Po = ½ ∆Pf).
NOTE 1 : Pressure are also limited by the rating of valves and connections.
NOTE 2 : ∆P are only given for a quick valve sizing.
(1) Max supply pressure : 1.7 bar.
(2) Max supply pressure : 2.4 bar.

You might also like