Contents p. 1-2
Corporate introduction p. 3
ATP Regulation p. 4-5
Calculating the vehicle body’s thermal rating p. 6
Transport temperature p. 7
Regulations about noise emissions p. 8
How to select a refrigeration unit p. 9
Guidance p. 10
Recommendations p. 11
What you will find in this guide p. 12-13
Line up for LCV units to 30°c p. 14
Line up for LCV units to 40°c p. 15
Line up for truck & trailer to 30°c p. 16
Line up for truck & trailer to 40°c p. 17
Light Commercial Vehicles p. 19
NEOS 100 p. 20-21
NEOS 100S p. 22-23
VIENTO 200 R134A p. 24-25
VIENTO 200 R404A p. 26-27
VIENTO 300 R134A p. 28-29
VIENTO 300 R404A p. 30-31
VIENTO 350 R134A p. 32-33
VIENTO 350 R404A p. 34-35
XARIOS 150 p. 36-37
XARIOS 200 p. 38-39
ZEPHYR 30S p. 40-41
XARIOS 300 p. 42-43
XARIOS 350 p. 44-45
XARIOS 500 p. 46-47
XARIOS 600 p. 48-49
PULSOR 350 p. 50-51
PULSOR 400 p. 52-53
PULSOR 500 p. 54-55
XARIOS 350 MT p. 56-59
XARIOS 600 MT p. 60-63
PULSOR 400 MT p. 64-67
PULSOR 600 MT p. 68-71
VATNA 150 H p. 72-73
VATNA 200 H - B p. 74-75
VATNA 300 H - B p. 76-77
VATNA 400 H - B p. 78-79
Trucks p. 81
SUPRA 450 p. 82-83
SUPRA 550 p. 84-85
SUPRA 750 p. 86-87
SUPRA 850 p. 88-89
1
Contents
SUPRA 950 p. 90-91
SUPRA 850 U p. 92-93
SUPRA 950 U p. 94-95
SUPRA 750 SW p. 96-97
SUPRA 900 CITY Z p. 98-99
SUPRA 1000 CITY Z p. 100-101
OASIS 150 p. 102-103
OASIS 250 p. 104-105
OASIS 350 p. 106-107
SUPRA 750 MT p. 108-111
SUPRA 850 MT p. 112-115
SUPRA 950 MT p. 116-119
SUPRA 950 U MT p. 120-123
SUPRA 1000 CITY Z MT p. 124-127
OASIS 250 MT p. 128-131
OASIS 350 MT p. 132-135
Trailers p. 137
MAXIMA 1000 p. 138-139
MAXIMA 1300 p. 140-141
VECTOR 1550 p. 142-143
VECTOR 1550 CITY p. 144-145
VECTOR 1850 p. 146-147
VECTOR E p. 148-149
ULTRA XL p. 150-151
X2100A p. 152-153
SOLARA p. 154-155
MAXIMA 1300 MT p. 156-159
VECTOR 1850 MT p. 160-163
Electronics p. 165
LogiCOLD p. 167
EasyCOLD p. 168
DataCOLD 250 p. 169
DataCOLD 500 p. 170
COLDTrans p. 171
COLDTouch p. 172
Light bar p. 173
Remote panel p. 174
Sensor monitor p. 175
Datashare p. 176
Datatrack p. 177
TRUTech p. 178
Fuel sensor p. 179
Our company is constantly seeking to improve the quality of its products and therefore
reserves the right to modify their characteristics without prior notice.
2
Corporate introduction
• Founded: 1902
• Key positioning: “You carry, we care”
• Europe, Russia, Middle East and Africa
• 16 integrated distribution
• 39 independent distributors
www.carriertransicoldeurope.com
3
ATP Regulation
Extract of A.T.P Europe regulations (March 1974)
Class A:
Refrigerated unit equipped with a cooling system allowing the selection of
temperatures between +12°C and 0°C inclusive.
Class B:
Refrigerated unit equipped with a cooling system allowing the selection of
temperatures between +12°C and -10°C inclusive.
Class C:
Refrigerated unit equipped with a cooling system allowing the selection of
temperatures between +12°C and -20°C inclusive.
The cooling capacity of a unit is determined by a test carried out in one of the registered
testing centers and certified by an official report.
4
ATP Regulation
Signs, identification :
This reference must be followed by the appropriate identification marks from the
following list:
In addition to the above identification marks, the date (month and year) of expiry of
the approval certificate must be indicated.
Important:
Check the expiry date of the approval certificate regularly. This certificate, or
equivalent temporary approval documents, must be supplied when requested by
qualified persons.
In the case of transformation of an insulated vehicle for refrigerated operation,
a request for modification of the approval certificate must be addressed to the
regional health authorities.
Note:
There are other rules and regulations applicable to the transport of temperature-
sensitive cargo (ARI for the USA – JIS for Japan). For further information on these
regulations, please contact our technical departments.
Refrigeration units presented in this selection guide are compliant with ATP
regulation in force at the time of their sales.
Any modification, transformation or diverted use from a product designed for the
transport of perishable foodstuffs can be made only under the full responsibility of
the bodybuilder, the rental company and/or the transport company with
impossibility to look for the liability of manufacturer or the seller of the refrigeration
unit.
5
Calculating the vehicle body’s
thermal rating
To determine the thermal rating of the vehicle body, use one of the following formulae:
• Ventilated units:
• Refrigeration units:
calculated as follows:
Ms = √ (int. s x ext. s)
int. s: total interior surface area of all body walls
ext. s: total exterior surface area of all body walls.
6
Transport temperature
During loading, check the internal temperature of the goods to be transported.
Frozen products
-25°C Ice and ice cream
-18°C Deep frozen foods
-18°C Fishery products
-14°C Butter and edible fats, including cream to be used for butter making
-12°C Egg products, offal, rabbit, poultry and game
-10°C Meat
Chilled products
+2°C Fresh fish (in ice), crustaceans and shellfish (excluding live ones)
+3°C Cooked dishes and prepared foods, pastry creams, fresh pastries, sweet dishes
and egg products
+3°C Meat and cooked meats pre-packaged for consumer use
+3°C Offal
+3°C Poultry, rabbit and game
+4°C Non-sterilized, untreated, unpasteurized or fermented milk, fresh cream, cottage
cheese and curd
+6°C Milk for industrial processing
+6°C Cooked meats other than those which have been salted, smoked, dried or steri-
lized
+6°C Chilled eggs in their shells
+6°C Butter, soft or blue cheeses
+7°C Meat
The above information is given for reference purposes only, and may be overridden on
the transporter or the consignee’s advice. More detailed information may be obtained
from your Carrier Transicold distributor.
7
Regulations about noise emissions
DIN 8958
• Measure the Noise level with 5 microphones
to find a Sound Pressure value. 1973
• Calculate a value similar to human ear
perception in dB
CE 2000-14 (NFR10-304)
• Close the source in a virtual hemisphere
created by 6 microphones
This is
mandatory /
sticker on unit
TNO-Piek
• This is not a regulation, but a label from
Netherlands for night time urban
distribution.
8
How to select a refrigeration unit
What sort of informations are required to make the right selection?
Selecting a refrigeration unit depends on many factors (see below). Users are therefore
recommended to read all the chapters in this manual before selecting their refrigeration
unit.
All these info should be provided before ordering the unit:
• Interior and exterior length of the body,
• Interior and exterior width of the body,
• Interior and exterior height of the body,
• K factor of the body
• Configuration of the box
Partition (mobile or fixed)
Evaporator position
• Number of door opening
• Ambient temperature,
• Temperature required inside compartments,
• Products to be transported,
• Road operation and / or standby operation,
• Type of use (long distance, local distribution, etc.),
• Other useful information.
For engine driven units*, it is also necessary to provide following information to select
appropriate accessories to drive our units:
• Vehicle battery voltage (12V or 24V),
• Air Conditioning (AC) or not,
• Alternator amperage,
• Type of engine,
• Engine displacement,
• Other useful information.
Our technicians are at your disposal to assist you in selecting a unit which corresponds to
your customer’s requirements.
9
Guidance
• The characteristics of the units described in • Selecting refrigeration units in
this guide are given for guidance only and relation to body/box volume is based
correspond to the ATP requirements on the following criteria:
applicable on the date of printing.
- safety coefficients:
• A diagram indicates the maximum
recommended volumes for use of each at 0°C: 4.5 instead of 1.75 (ATP
refrigeration unit, based on the ambient regulation)
temperature and the temperature required at -20°C: 2.5 instead of 1.75 (ATP
inside the truck body regulation)
- door openings:
10
Recommendations
The following recommendations When transporting frozen products:
should be observed when using refri- • If the hygrometry ratio is high, initiate a ma-
geration units. nual defrost 30 minutes after loading.
• Shut down the unit when you open the
In a very cold climate: doors to avoid excessive frosting of the eva-
• Units which operate in a very cold porator.
climate require high quality oil cor-
responding to the manufacturer’s When transporting ice cream:
specifications, a diesel fuel heater • Use protective curtains if the doors are to
and low temperature-resistant coo- be opened frequently.
lant. • Shut down the unit when you open the
• For temperature control, units should doors.
not be allowed to shut down auto- • With small-bodied vehicles (< 22 m3)
matically with the diesel engine. choose an electric system in preference to
a direct drive mechanism.
For LCV units
• Hot gas heating is recommended For urban deliveries:
when transporting goods requiring • Use protective curtains.
positive temperatures (≥ 0°C). • Shut down the unit when you open the
doors.
In a hot climate: • Before loading, pre-refrigerate the vehicle
• Units which operate in a very hot body to a temperature at least as low as
climate require high-quality oil cor- that of the goods to be transported.
responding to the manufacturer’s
specifications For long journeys:
• Units equipped with Start-Stop me- • Check that the unit is operating correctly.
chanisms should not be allowed to • In the event of a problem arising, contact
stop during temperature control use the nearest service center, or call our 24-
with frozen products onboard. hours-a-day, 7-days-a-week service as
• The vehicle should always be par- soon as possible.
ked in the shade.
Always:
When loading: • Take regular care of your unit as advised by
• Do not obstruct the evaporator with CARRIER in order to avoid any unnecessary
the loaded goods. problems.
• Make sure that air circulation is not
impeded (for example, when loading
film-covered pallets, make sure that
the air can flow back unobstructed
under the pallets).
11
What you will find in this guide
SUPRA 950 MT
Total flexibility for multi-product deliveries with ultra-slim evaporators that
can be adapted to large configuration requirement
Main
1995
product’s
picture
699
Weight
without
accessories
940
-20°C
User
Interface 30° C 40° C
57 m3 41 m3
Recommended
body volume
(see page 10) Notes
116
12
What you will find in this guide
SUPRA 950 MT
ATP - Certificate n° M 708
Nominal capacity at -20°C / 30°C 5865 W Capacities
Evaporator MTS 700 MTS 1100 MTS 1450 MTS 2200 MTD 1450 MTD 2200 and airflow
Diesel High Speed capacity
0°C / 30 ° C W 6335 8150 9355 9375 9885 9985
-20°C / 30 ° C W 3495 4360 5330 5130 5390 5675
Standby capacity
0°C / 30 ° C W 5925 8100 9215 9200 9540 9680
-20°C / 30 ° C W 3525 4420 5300 5245 5370 5750 Refrigerant’s
Airflow charge
(AMCA 21085) m3/h 1220 2170 2590 3615 2605 3800
Heating Capacity
Diesel High speed 18°C/-18°C W 4500 5015 5600 5480 5635 5805
Standby 18°C/-18°C W 4515 5052 5580 5545 5620 5850
Sound
Compressor Refrigerant
pressure
Model O5G Type R404A
Nb of Cylinders 6 Charge Depending on configuration (see page 8)
Displacement cm3 600 Sound pressure high speed
Diesel engine Standard dBA 69,6
Model CT3-69TV Low noise dBA 68,4
Nb of Cylinders 3 Silent dBA 65,4
Displacement cm3 1123 Sound pressure low speed
Oil change interval hrs 750 / 1000
Standard dBA 67,2
Standby motor Low noise dBA 66,1 Technical
Standby voltage V/Ph/Fr • 230/400/3/50 Hz Silent dBA 62,4
Power (50 Hz) kW 9 datas
Sound pressure standby
Standard dBA 61,5
Low noise dBA 62,1
List of main
Standard equipment Accessories or options options
(S model ) • Battery
• Cab command • Battery box
• EasyCOLD microprocessor • Fuel tank 90 or 200 L
• Start/Stop • Automatic phase reverser Description
• Standby/Diesel hourmeter • DataCOLD 250 or 500
• Automatic diesel restart • Oil drain extension
of main
(T model) • Control panel & cable extension features for
• Low noise kit • Door switch each version
(X model) • Water drain kit for evaporator (MTS
• Silent kit 1100 & MTS 1450)
available
117
13
Line up for LCV units to 30°c
Classification C A
Temperature -20°C (-4°F) 0° +2°C (+32° +35°F)
Required K factor 0,38 Watts/m2 °C
RANGE AND
TYPE OF UNIT VOLUME OF THE INSULATED BODY IN M3
0 10 20 30 40 50
ELECTRIC-DRIVE
NEOS 100
NEOS 100S
PULSOR 350
PULSOR 400
PULSOR 500
DIRECT-DRIVE
VIENTO 200 R134a
VIENTO 200 R404A
VIENTO 300 R134a
VIENTO 300 R404A
VIENTO 350 R134a
VIENTO 350 R404A
XARIOS 150
XARIOS 200
ZEPHYR 30S
XARIOS 300
XARIOS 350
XARIOS 500
XARIOS 600
MULTI-TEMPERATURE
XARIOS 350 MT
XARIOS 600 MT
PULSOR 400 MT
PULSOR 600 MT
Note : This selection table is intended as a guide. It has been compiled using experience acquired in normal utilization of our equipment in transport
and distribution.
Conformity to these recommendations should guarantee your total satisfaction. The maximum volumes indicated in the table above are given for
a road operation at 2400 rpm. Since the speed of the road compressor depends on the vehicle motor speed, the unit's refrigerating capacity
varies in relation to the use made of the vehicle (except for Pulsor & Neos) . Take into account the unit's standby performance characteris-
tics or consult us if the unit is frequently used on standby.
In case of operation in high ambient temperature or for difficult types of transport (fresh meat, cheese, vegetables, etc.), it is advised to base your
choice on a volume equivalent to the next lowest temperature range. For example, with a XARIOS 300 - R404A, volume should not exceed 17 m3.
When one of the parameters (volume, K factor or outside temperature) differs from the above data, you should apply the following formula: • P = K x
Ms x ΔT x 1,75 after referring to the refrigerating capacities.
LIMITS OF USE OF THE ABOVE TABLE : • Altitude ≤ 1500 m • Relative humidity ≤ 70%. For other conditions of use, please consult us.
14
Line up for LCV units to 40°c
Classification C A
Temperature -20°C (-4°F) 0° +2°C (+32° +35°F)
Required K factor 0,38 Watts/m2 °C
RANGE AND
TYPE OF UNIT VOLUME OF THE INSULATED BODY IN M3
10 20 30
ELECTRIC-DRIVE
NEOS 100
NEOS 100S
PULSOR 350
PULSOR 400
PULSOR 500
DIRECT-DRIVE
VIENTO 200 R134a
VIENTO 200 R404A
VIENTO 300 R134a
VIENTO 300 R404A
VIENTO 350 R134a
VIENTO 350 R404A
XARIOS 150
XARIOS 200
ZEPHYR 30S
XARIOS 300
XARIOS 350
XARIOS 500
XARIOS 600
MULTI-TEMPERATURE
XARIOS 350 MT
XARIOS 600 MT
PULSOR 400 MT
PULSOR 600 MT
Note : This selection table is intended as a guide. It has been compiled using experience acquired in normal utilization of our equipment in transport
and distribution.
Conformity to these recommendations should guarantee your total satisfaction. The maximum volumes indicated in the table above are given for
a road operation at 2400 rpm. Since the speed of the road compressor depends on the vehicle motor speed, the unit's refrigerating capacity
varies in relation to the use made of the vehicle (except for Pulsor & Neos) . Take into account the unit's standby performance characteris-
tics or consult us if the unit is frequently used on standby.
In case of operation in high ambient temperature or for difficult types of transport (fresh meat, cheese, vegetables, etc.), it is advised to base your
choice on a volume equivalent to the next lowest temperature range. For example, with a XARIOS 300 - R404A, volume should not exceed 17 m3.
When one of the parameters (volume, K factor or outside temperature) differs from the above data, you should apply the following formula: • P = K x
Ms x ΔT x 1,75 after referring to the refrigerating capacities.
LIMITS OF USE OF THE ABOVE TABLE : • Altitude ≤ 1500 m • Relative humidity ≤ 70%. For other conditions of use, please consult us.
15
Line up for truck & trailer to 30°c
Classification C A
Temperature -20°C (-4°F) 0° +2°C (+32° +35°F)
Required K factor 0,38 Watts/m2 °C
RANGE AND
TYPE OF UNIT VOLUME OF THE INSULATED BODY IN M3
10 20 30 40 50 60 70 80 90 100
TRUCKS
SUPRA 450
SUPRA 550
SUPRA 750
SUPRA 750 SW
SUPRA 850
SUPRA 950
UNDERMOUNT
SUPRA 850 U
SUPRA 950 U
ZERO EMISSION
SUPRA 900 CITY Z
SUPRA 1000 CITY Z
HIGH AMBIANCE
OASIS 150 (40° C)
OASIS 250 (40° C)
OASIS 350 (40° C)
MULTI-TEMPERATURE
SUPRA 750 MT
SUPRA 850 MT
SUPRA 950 MT
SUPRA 950 U MT
SUPRA 1000 CITY Z MT
OASIS 250 MT (40° C)
OASIS 350 MT (40° C)
TRAILERS
MAXIMA 1000
MAXIMA 1300
VECTOR 1550
VECTOR 1850
ULTRA XL
X2100A
PIEK
VECTOR 1550 CITY
ZERO EMISSION
VECTOR E
MULTI-TEMPERATURE
MAXIMA 1300 MT
VECTOR 1850 MT
Note : This selection table is intended as a guide. It has been compiled using experience acquired in normal utilization of our equipment in transport
and distribution. Conformity to these recommendations should guarantee your total satisfaction. The maximum volumes figuring in this table are
given for high speed engine operation. Take into account the unit's standby performance characteristics (these are indicated in the sale
literature) if the unit is frequently used on standby.In case of operation in high ambient temperature or for difficult types of transport (fresh meat,
cheese, vegetables, etc.), it is advised to base your choice on a volume equivalent to the next lowest temperature range. For example, with a SUPRA
550, volume should not exceed 35 m3. When one of the parameters (volume, K factor or outside temperature) differs from the above data, you should
apply the following formula: • P = K x Ms x ΔT x 1,75 after referring to the refrigerating capacities.
LIMITS OF USE OF THE ABOVE TABLE : • Altitude ≤ 1500 m • Relative humidity ≤ 70%
16
Line up for truck & trailer to 40°c
Classification C A
Temperature -20°C (-4°F) 0° +2°C (+32° +35°F)
Required K factor 0,38 Watts/m2 °C
RANGE AND
TYPE OF UNIT VOLUME OF THE INSULATED BODY IN M3
10 20 30 40 50 60 70 80 90 100
TRUCKS
SUPRA 450
SUPRA 550
SUPRA 750
SUPRA 750 SW
SUPRA 850
SUPRA 950
UNDERMOUNT
SUPRA 850 U
SUPRA 950 U
ZERO EMISSION
SUPRA 900 CITY Z
SUPRA 1000 CITY Z
HIGH AMBIANCE
OASIS 150 (50° C)
OASIS 250 (50° C)
OASIS 350 (50° C)
MULTI-TEMPERATURE
SUPRA 750 MT
SUPRA 850 MT
SUPRA 950 MT
SUPRA 950 U MT
SUPRA 1000 CITY Z MT
OASIS 250 MT (50° C)
OASIS 350 MT (50° C)
TRAILERS
MAXIMA 1000
MAXIMA 1300
VECTOR 1550
VECTOR 1850
ULTRA XL
X2100A
PIEK
VECTOR 1550 CITY
ZERO EMISSION
VECTOR E
MULTI-TEMPERATURE
MAXIMA 1300 MT
VECTOR 1850 MT
Note : This selection table is intended as a guide. It has been compiled using experience acquired in normal utilization of our equipment in transport
and distribution. Conformity to these recommendations should guarantee your total satisfaction. The maximum volumes figuring in this table are
given for high speed engine operation. Take into account the unit's standby performance characteristics (these are indicated in the sale
literature) if the unit is frequently used on standby.In case of operation in high ambient temperature or for difficult types of transport (fresh meat,
cheese, vegetables, etc.), it is advised to base your choice on a volume equivalent to the next lowest temperature range. For example, with a SUPRA
550, volume should not exceed 35 m3. When one of the parameters (volume, K factor or outside temperature) differs from the above data, you should
apply the following formula: • P = K x Ms x ΔT x 1,75 after referring to the refrigerating capacities.
LIMITS OF USE OF THE ABOVE TABLE : • Altitude ≤ 1500 m • Relative humidity ≤ 70%
17
NOTES
18
Light Commercial Vehicles
NEOS 100
Alternator driven refrigeration unit for small delivery vehicles
800 1000
58
822 904
233
-20°C 0+2°C
30° C 40° C
2 m3 1 m3
6 m3 4 m3
Notes
20
NEOS 100
ATP - Certificate n° M626 Road compressor
Evaporator integrated Model SD5H09
Nb of Cylinders 5
Capacity on road at 1000 rpm Displacement cm3 87
0°C / 30 ° C W 1140 Standby
-20°C / 30 ° C W 425
Voltage V/Ph/Fr • 230/1/50 Hz
Standby capacity • 230/1/60 Hz
0°C/30°C W 1140 Consumption (50 Hz) W 1420
-20°C/30°C W 425
Airflow Refrigerant
(AMCA 21085) m3/h 700 Type R134a
Charge kg 0,9
Sound pressure
High speed dBA 57
21
NEOS 100S
Alternator driven refrigeration unit for small delivery vehicles
480 864
232
Evaporator Weight
MNS 600 : 15 kg
548 608
-20°C 0+2°C
165
30° C 40° C
2 m3 1 m3
6 m3 4 m3
Notes
22
NEOS 100S
ATP - Certificate n° M681 Road compressor
Evaporator MNS 600 Model SD5H09
Nb of Cylinders 5
Capacity on road at 1000 rpm Displacement cm3 87
0°C / 30 ° C W 1165 Standby
-20°C / 30 ° C W 450
Voltage V/Ph/Fr • 230/1/50 Hz
Standby capacity • 230/1/60 Hz
0°C/30°C W 1200 Consumption (50 Hz) W 1420
-20°C/30°C W 450
Airflow Refrigerant
(AMCA 21085) m3/h 700 Type R134a
Charge kg 1
Sound pressure
High speed dBA 57
23
VIENTO 200 R134a
Simple, road-only unit
For delivery vans
874
194
505
Evaporator Weight
MZS 850 : 17 kg
30° C 40° C
120
10 m3 6 m3
170
16 m3 9 m3
weight : 17 kg
Notes
24
VIENTO 200 R134a
ATP - Certificate n° M 622 Road compressor
Evaporator MZS 850 Model TM 13
Nb of Cylinders 6
Capacity on road at 2400 rpm Displacement cm3 131
0°C/30°C W 1950
-20°C/30°C W 960 Refrigerant
Capacity on road at 1000 rpm Type R134a
0°C / 30 ° C W 1400 Charge kg 0,85
-20°C / 30 ° C W 625 Sound pressure
Airflow High speed dBA 57
(AMCA 21085) m3/h 950
Heating Capacity
Heating system 18°C/-18°C W 950
25
VIENTO 200 R404A
Simple, road-only unit
For delivery vans
874
194
505
Poids
Evaporator
de l’évaporateur
Weight
MZS 600 : 15 kg
30° C 40° C
10 m3 6 m3
165
16 m3 9 m3
weight : 16 kg
Notes
26
VIENTO 200 R404A
ATP - Certificate n° M 621 Road compressor
Evaporator MZS 600 Model SD5H09
Nb of Cylinders 5
Capacity on road at 2400 rpm Displacement cm3 87
0°C/30°C W 2000
-20°C/30°C W 1025 Refrigerant
Capacity on road at 1000 rpm Type R404A
0°C / 30 ° C W 1465 Charge kg 0,85
-20°C / 30 ° C W 690 Sound pressure
Airflow High speed dBA 57
(AMCA 21085) m3/h 670
Heating Capacity
Heating system 18°C/-18°C W 1000
27
VIENTO 300 R134a
Simple, road-only unit
For delivery vans
874
194
505
Poids
Evaporator
de l’évaporateur
Weight
MZL 850 : 17 kg
-20°C 0+2°C
614 860
30° C 40° C
150
12 m3 8 m3
193
21 m3 12 m3
weight : 17 kg
Notes
28
VIENTO 300 R134a
ATP - Certificate n° M 607 Road compressor
Evaporator MZL 850 Model TM 15
Nb of Cylinders 6
Capacity on road at 2400 rpm Displacement cm3 146
0°C/30°C W 2600
-20°C/30°C W 1330 Refrigerant
Capacity on road at 1000 rpm Type R134a
0°C / 30 ° C W 1690 Charge kg 1
-20°C / 30 ° C W 675 Sound pressure
Airflow High speed dBA 54
(AMCA 21085) m3/h 1050
Heating Capacity
Heating system 18°C/-18°C W 1250
29
VIENTO 300 R404A
Simple, road-only unit
For delivery vans
874
194
505
Poids
Evaporator
de l’évaporateur
Weight
MZS 850 : 17 kg
-20°C 0+2°C
857
608
30° C 40° C
120
16 m3 10 m3
170
21 m3 12 m3
weight : 17 kg
Notes
30
VIENTO 300 R404A
ATP - Certificate n° M 609 Road compressor
Evaporator MZS 850 Model TM 13
Nb of Cylinders 6
Capacity on road at 2400 rpm Displacement cm3 131
0°C/30°C W 2740
-20°C/30°C W 1645 Refrigerant
Capacity on road at 1000 rpm Type R404A
0°C / 30 ° C W 1980 Charge kg 1
-20°C / 30 ° C W 1175 Sound pressure
Airflow High speed dBA 54
(AMCA 21085) m3/h 950
Heating Capacity
Heating system 18°C/-18°C W 1600
31
VIENTO 350 R134a
Simple, road-only unit
For delivery vans
874
205
505
Evaporator Weight
MZL 1100 : 23 kg
-20°C 0+2°C
614 1100
30° C 40° C
150
14 m3 10 m3
193
28 m3 17 m3
weight : 23 kg
Notes
32
VIENTO 350 R134a
ATP - Certificate n° M 611 Road compressor
Evaporator MZL 1100 Model TM 16
Nb of Cylinders 6
Capacity on road at 2400 rpm Displacement cm3 164
0°C/30°C W 3300
-20°C/30°C W 1610 Refrigerant
Capacity on road at 1000 rpm Type R134a
0°C / 30 ° C W 2305 Charge kg 1,1
-20°C / 30 ° C W 990 Sound pressure
Airflow High speed dBA 54,5
(AMCA 21085) m3/h 1600
Heating Capacity
Heating system 18°C/-18°C W 1600
33
VIENTO 350 R404A
Simple, road-only unit
For delivery vans
874
205
505
Evaporator Weight
MZS 1100 : 23 kg
614 1100
-20°C 0+2°C
150
30° C 40° C
193
21 m3 15 m3
28 m3 17 m3 weight : 23 kg
Notes
34
VIENTO 350 R404A
ATP - Certificate n° M 610 Road compressor
Evaporator MZS 1100 Model TM 15
Nb of Cylinders 6
Capacity on road at 2400 rpm Displacement cm3 146
0°C/30°C W 3470
-20°C/30°C W 2060 Refrigerant
Capacity on road at 1000 rpm Type R404A
0°C / 30 ° C W 2090 Charge kg 1,1
-20°C / 30 ° C W 1195 Sound pressure
Airflow High speed dBA 54,5
(AMCA 21085) m3/h 1660
Heating Capacity
Heating system 18°C/-18°C W 1900
35
XARIOS 150
Modular range for vans and medium-sized refrigerated vehicles
480 864
232
Evaporator Weight
MXS 600 : 15 kg
603
-20°C 0+2°C 548
120
30° C 40° C
172
8 m3 6 m3
12 m3 9 m3
weight : 15 kg
Notes
36
XARIOS 150
ATP - Certificate n° M625 Road compressor
Evaporator MXS 600 Model SD5H09
Nb of Cylinders 5
Capacity on road at 2400 rpm Displacement cm3 87
0°C/30°C W 1945 Standby Compressor
-20°C/30°C W 980
Model HAF0902B1A
Capacity on road at 1000 rpm Nb of Cylinders Rotary
0°C / 30 ° C W 1535 Displacement cm3 12,7
-20°C / 30 ° C W 680 Standby
Standby capacity Voltage V/Ph/Fr • 230/1/50 Hz
0°C/30°C W 1130 • 400/3/50 Hz
-20°C/30°C W 495 Consumption (50 Hz) W 1020
Airflow
(AMCA 21085) m3/h 650 Refrigerant
Type R404A
Heating Capacity
Charge kg 1,2
Heating system 18°C/-18°C W 1800
Sound pressure
High speed dBA 54,6
37
XARIOS 200
Modular range for vans and medium-sized refrigerated vehicles
480 864
232
853 159
853
608
120
628
172
weight : 19 kg
weight : 17 kg
30° C 40° C
12 m3 9 m3
17 m3 11 m3
38
XARIOS 200
ATP - Certificate n° M743 M742
Evaporator MXV 850 MXS 850
Capacity on road at 2400 rpm
0°C/30°C W 2370 2370
-20°C/30°C W 1330 1500
Capacity on road at 1000 rpm
0°C / 30 ° C W 1840 1570
-20°C / 30 ° C W 845 1005
Standby capacity
0°C/30°C W 1190 1225
-20°C/30°C W 560 515
Airflow
(AMCA 21085) m3/h 820 830
Heating Capacity
Heating system 18°C/-18°C W 2200 2200
39
ZEPHYR 30S
Proven versatility and reliability for medium-sized delivery vehicles
30° C 40° C
13 m3 9 m3
23 m3 16 m3
40
ZEPHYR 30S
ATP - Certificate n° M664
Evaporator Cubic Evap Roof Evap
Capacity on road at 2400 rpm
0°C/30°C W 2730 3060
-20°C/30°C W 1280 1525
Capacity on road at 1000 rpm
0°C / 30 ° C W 1910 1975
-20°C / 30 ° C W 785 930
Standby capacity
0°C/30°C W 1930 1990
-20°C/30°C W 780 850
Airflow
(AMCA 21085) m3/h 860 1060
Heating Capacity
Heating system 18°C/-18°C W 1250 1300
41
XARIOS 300
Modular range for vans and medium-sized refrigerated vehicles
1125
505
238
853 159
853
608
120
628
172
weight : 19 kg
weight : 17 kg
30° C 40° C
17 m3 13 m3
22 m3 15 m3
42
XARIOS 300
ATP - Certificate n° M640 M639
Evaporator MXV 850 MXS 850
Capacity on road at 2400 rpm
0°C/30°C W 2670 2870
-20°C/30°C W 1625 1700
Capacity on road at 1000 rpm
0°C / 30 ° C W 2185 1770
-20°C / 30 ° C W 1235 1135
Standby capacity
0°C/30°C W 1820 2030
-20°C/30°C W 870 895
Airflow
(AMCA 21085) m3/h 770 800
Heating Capacity
Heating system 18°C/-18°C W 2800 2800
43
XARIOS 350
Modular range for vans and medium-sized refrigerated vehicles
1125
505
238
Evaporator Weight
MXS 1100 : 29 kg
-20°C 0+2°C
614 1106
30° C 40° C
20 m3 15 m3
150
194
28 m3 17 m3
weight : 29 kg
Notes
44
XARIOS 350
ATP - Certificate n° M628 Road compressor
Evaporator MXS 1100 Model TM15
Nb of Cylinders 6
Capacity on road at 2400 rpm Displacement cm3 147
0°C/30°C W 3530 Standby Compressor
-20°C/30°C W 2020
Model TM15
Capacity on road at 1000 rpm Nb of Cylinders 6
0°C / 30 ° C W 2533 Displacement cm3 147
-20°C / 30 ° C W 1227 Standby
Standby capacity Voltage V/Ph/Fr • 230/1/50 Hz
0°C/30°C W 2260 • 400/3/50 Hz
-20°C/30°C W 1095 Consumption (50 Hz) W 2520
Airflow
(AMCA 21085) m3/h 1520 Refrigerant
Type R404A
Heating Capacity
Charge kg 1,4
Heating system 18°C/-18°C W 3100
Sound pressure
High speed dBA 57
45
XARIOS 500
Modular range for vans and medium-sized refrigerated vehicles
80 kg 144 kg
514 1367
498
Evaporator Weight
MXL 1100 : 29 kg
-20°C 0+2°C
614 1106
30° C 40° C
28 m3 21 m3
150
194
36 m3 25 m3
weight : 29 kg
Notes
46
XARIOS 500
ATP - Certificate n° M709 Road compressor
Evaporator MXL 1100 Model TM16
Nb of Cylinders 6
Capacity on road at 2400 rpm Displacement cm3 161
0°C/30°C W 4740 Standby Compressor
-20°C/30°C W 2640
Model 06 VM 306
Capacity on road at 1000 rpm Nb of Cylinders 2
0°C / 30 ° C W 3550 Displacement cm3 113
-20°C / 30 ° C W 1760 Standby
Standby capacity Voltage V/Ph/Fr • 230/1/50 Hz
0°C/30°C W 3370 • 400/3/50 Hz
-20°C/30°C W 1575 • 230/3/60 Hz
Consumption (50 Hz) W 3000
Airflow
(AMCA 21085) m3/h 1450
Refrigerant
Heating Capacity
Type R404A
Heating system 18°C/-18°C W 3600 Charge kg 3
Sound pressure
High speed dBA 54,6
47
XARIOS 600
Modular range for vans and medium-sized refrigerated vehicles
83 kg 147 kg
514 1367
498
Evaporator Weight
MXL 1550 : 42 kg
-20°C 0+2°C
614 1556
30° C 40° C
194
150
32 m3 24 m3
40 m3 28 m3
weight : 29 kg
Notes
48
XARIOS 600
ATP - Certificate n° M730 Road compressor
Evaporator MXL 1550 Model TM16
Nb of Cylinders 6
Capacity on road at 2400 rpm Displacement cm3 161
0°C/30°C W 5585 Standby Compressor
-20°C/30°C W 2950
Model 06 VM 307
Capacity on road at 1000 rpm Nb of Cylinders 2
0°C / 30 ° C W 4145 Displacement cm3 129
-20°C / 30 ° C W 1915 Standby
Standby capacity Voltage V/Ph/Fr • 230/1/50 Hz
0°C/30°C W 4140 • 400/3/50 Hz
-20°C/30°C W 1840 • 230/3/60 Hz
Consumption (50 Hz) W 3170
Airflow
(AMCA 21085) m3/h 2090
Refrigerant
Heating Capacity
Type R404A
Heating system 18°C/-18°C W 3950 Charge kg 3,2
Sound pressure
High speed dBA 55
49
PULSOR 350
Constant Cold throughout the day
577 1124
235
Evaporator Weight
MCL 850 : 22 kg
30° C 40° C
18 m3 14 m3
194
24 m3 16 m3
Notes
50
PULSOR 350
ATP - Certificate n° M705 Road compressor
Evaporator MCL 850 Model BS330 / MS330
Nb of Cylinders -
Capacity on road at 2400 rpm Displacement cm3 32,7
0°C/30°C W 3110 Standby
-20°C/30°C W 1780
Voltage V/Ph/Fr • 400/3/50 Hz
Capacity on road at 1000 rpm • 400/3/60 Hz
0°C / 30 ° C W 3110 Consumption (50 Hz) W 4500
-20°C / 30 ° C W 1780
Standby capacity Refrigerant
0°C/30°C W 3160 Type R404A
-20°C/30°C W 1805 Charge kg 1,7
Airflow Sound pressure
(AMCA 21085) m3/h 1000 High speed dBA 57
Heating Capacity
Heating system 18°C/-18°C W 2100
Standby 18°C/-18°C W 2100
51
PULSOR 400
Constant Cold throughout the day
577 1124
235
Evaporator Weight
MCL 1100 : 30 kg
30° C 40° C
20 m3 15 m3
194
28 m3 17 m3
Notes
52
PULSOR 400
ATP - Certificate n° M704 Road compressor
Evaporator MCL 1100 Model BS330 / MS330
Nb of Cylinders -
Capacity on road at 2400 rpm Displacement cm3 32,7
0°C/30°C W 3575 Standby
-20°C/30°C W 1930
Voltage V/Ph/Fr • 400/3/50 Hz
Capacity on road at 1000 rpm • 400/3/60 Hz
0°C / 30 ° C W 3575 Consumption (50 Hz) W 5250
-20°C / 30 ° C W 1930
Standby capacity Refrigerant
0°C/30°C W 3615 Type R404A
-20°C/30°C W 1915 Charge kg 1,8
Airflow Sound pressure
(AMCA 21085) m3/h 1580 High speed dBA 57
Heating Capacity
Heating system 18°C/-18°C W 3000
Standby 18°C/-18°C W 3000
53
PULSOR 500
Constant Cold throughout the day
579 1289
353
-20°C 0+2°C
30° C 40° C
24 m3 17 m3
32 m3 21 m3
Notes
54
PULSOR 500
ATP - Certificate n° M688 Road compressor
Capacity on road at 2400 rpm Model BS330 / MS330
Nb of Cylinders -
0°C/30°C W 3930
Displacement cm3 32,7
-20°C/30°C W 2165
Standby
Capacity on road at 1000 rpm
Voltage V/Ph/Fr • 400/3/50 Hz
0°C / 30 ° C W 3930
• 400/3/60 Hz
-20°C / 30 ° C W 2165
Consumption (50 Hz) W 3340
Standby capacity
0°C/30°C W 3985 Refrigerant
-20°C/30°C W 2180 Type R404A
Airflow Charge kg 1,8
(AMCA 21085) m3/h 1580 Sound pressure
Heating Capacity High speed dBA 57
Heating system 18°C/-18°C W 3000
Standby 18°C/-18°C W 3000
55
XARIOS 350 MT
Modular range for vans and medium-sized refrigerated vehicles
43 kg 87 kg
1125
505
238
Evaporator Weight
MXS 850 : 19 kg
MXS 600 : 15 kg
MXV 850 : 17 kg
-20°C
30° C 40° C
15 m3 12 m3
Notes
56
XARIOS 350 MT
ATP - Certificate n° M636
Nominal capacity at -20°C / 30°C 1920 W
Evaporator MXS 850 MXS 600 MXV 850
Capacity on road at 2400 rpm
0°C/30°C W 2780 2390 2695
-20°C/30°C W 1650 1350 1575
Standby capacity
0°C/30°C W 1900 1720 1810
-20°C/30°C W 890 770 885
Airflow
(AMCA 21085) m3/h 840 650 770
Heating Capacity
Heating system 18°C/-18°C W 3100
57
XARIOS 350 MT
628
165
MXS 850
856
646
194
58
XARIOS 350 MT
> 0.95
< 10 m3
850
< 10 m3
850
B
> 0.7 m
< 0.9 m
850
> 0.95
600
< 10 m3
< 1.3 m
A B
< 10 m3 < 10 m3
850
850
< 10 m3
850
600
> 0.7 m
< 0.9 m
A+B < 17 m3
MXV 850 + MXV 850
3
< 10 m < 17 m3
850
< 10 m3 < 10 m3
> 0.95
850
A+B < 17 m3
< 17 m3
850
850 < 10 m3
850
< 10 m3
Volumes are given for +30°C ambient temperature and few door opening.
Extension kit
Temperature in compartments are complety reversible: from -20°C to +10°C.
59
XARIOS 600 MT
Modular range for vans and medium-sized refrigerated vehicles
88 kg 152 kg
514 1367
498
Evaporator Weight
MXL 1100 : 29 kg
MXS 850 : 19 kg
-20°C
MXS 600 : 15 kg
MXV 850 : 17 kg
30° C 40° C
27 m3 20 m3
Notes
60
XARIOS 600 MT
ATP - Certificate n° M721
Nominal capacity at -20°C / 30°C 2925 W
Evaporator MXL 1100 MXS 850 MXS 600 MXV 850
Capacity on road at 2400 rpm
0°C/30°C W 4635 3465 2860 3435
-20°C/30°C W 2590 2105 1590 2030
Standby capacity
0°C/30°C W 3610 2890 2355 1465
-20°C/30°C W 1700 1500 1250 2890
Airflow
(AMCA 21085) m3/h 1560 800 700 855
Heating Capacity
Heating system 18°C/-18°C W 3950
61
XARIOS 600 MT
MXL 1100 MXS 600
120
150
194
172
853 159
853
608
120
628
172
62
XARIOS 600 MT
MXS 850 + MXL 1100 MXS 850 + MXS 850
A+B < 27 m3
> 0.95 m
850
> 0.95 m
850
< 10 m3 < 10 m3
> 1.2 m
B
1100
> 0.95 m
850
< 20 m3 < 10 m3
1.7 m mini
A B
< 10 m3 < 10 m3 < 10 m3
1100
< 20 m3
A+B < 27 m3
A B
< 10 m3
1100
850
850
850
< 20 m3 < 10 m3 1< 10 m3
A+B < 27 m3
< 27 m3
3
< 20 m < 10 m3
1100
1100
600
< 10 m3
1100
1100
< 20 m3 < 27 m3
Volumes are given for +30°C ambient temperature and few door opening. Extension kit
Temperature in compartments are complety reversible: from -20°C to +10°C.
63
PULSOR 400 MT
Constant Cold throughout the day
577 1124
235
Evaporator Weight
MCL 850 : 22 kg
MCV 850 : 19 kg
MCS 600 : 17 kg
-20°C
30° C 40° C
17 m3 13 m3
Notes
64
PULSOR 400 MT
ATP - Certificate n° M703
Nominal capacity at -20°C / 30°C 1930 W
Evaporator MCL 850 MCV 850 MCS 600
Capacity on road at 2400 rpm
0°C/30°C W 3115 2810 2525
-20°C/30°C W 1785 1575 1260
Capacity on road at 1000 rpm
0°C / 30 ° C W 3115 2810 2525
-20°C / 30 ° C W 1785 1575 1260
Standby capacity
0°C/30°C W 3160 2780 2580
-20°C/30°C W 1805 1570 1275
Airflow
(AMCA 21085) m3/h 1000 1000 700
Heating Capacity
Heating system 18°C/-18°C W 2100 2100 1500
Standby 18°C/-18°C W 2100 2100 1500
65
PULSOR 400 MT
MCS 600 MCV 850
628
165
MCL 850
856
646
194
66
PULSOR 400 MT
MCL 850 + MCL 850 MCS 600 + MCL 850
A+B < 17 m3 A+B < 17 m3
< 10 m3 < 10 m3
850
B
< 0.9 m
850
600
< 10 m3
A B
850
850
< 10 m3
850
< 10 m3 < 10 m3
600
A+B < 17 m3
MCV 850 + MCV 850
< 10 m3 17 m3 max
850
> 0.95 m
< 10 m3 < 10 m3
850
A+B < 17 m3
< 10 m3
850 < 10 m3
850
< 10 m3
Volumes are given for +30°C ambient temperature and few door opening. Extension kit
Temperature in compartments are complety reversible: from -20°C to +10°C.
67
PULSOR 600 MT
Constant Cold throughout the day
579 1289
353
Evaporator Weight
MCL 1100 : 30 kg
MCL 850 : 22 kg
MCS 600 : 17 kg
-20°C
30° C 40° C
22 m3 16 m3
Notes
68
PULSOR 600 MT
ATP - Certificate n° M687
Nominal capacity at -20°C / 30°C 2375 W
Evaporator MCL 1100 MCL 850 MCS 600
Capacity on road at 2400 rpm
0°C/30°C W 3930 3390 2725
-20°C/30°C W 2170 1930 1575
Capacity on road at 1000 rpm
0°C / 30 ° C W 3930 3390 2725
-20°C / 30 ° C W 2170 1930 1575
Standby capacity
0°C/30°C W 3985 3450 2755
-20°C/30°C W 2180 1950 1585
Airflow
(AMCA 21085) m3/h 1580 1030 695
Heating Capacity
Heating system 18°C/-18°C W 3000 2100 1500
Standby 18°C/-18°C W 3000 2100 1500
69
PULSOR 600 MT
MCL 1100 MCS 600
165
MCS 850
856
646
194
70
PULSOR 600 MT
MCL 850 + MCL 1100 MCL 850 + MCL 850
A+B < 22 m3
> 0.95 m
850
> 0.95 m
850
< 8 m3 < 8 m3
> 1.2 m
B
1100
> 0.95 m
850
< 13 m3 < 8 m3
1.7 m mini
A B
< 8 m3 < 8 m3
< 8 m3
1100
< 13 m3
A+B < 22 m3
A B
< 8 m3 < 8 m3 < 8 m3
1100
850
850
< 13 m3
850
A+B < 22 m3
< 13 m3
1100
1100
< 13 m3
600
Volumes are given for +30°C ambient temperature and few door opening. Extension kit
Temperature in compartments are complety reversible: from -20°C to +10°C.
71
VATNA 150 H
Eutectic technology for your delivery vehicle
90 kg
420
Plate weight
85 kg
59 1590 30 mini
60
Plate thickness
690
52 mm
52
-20°C
30° C 40° C
5 m3 4 m3
72
VATNA 150 H
ATP - Certificate n° BxRe1057 Motocompressor
Model VATNA 152 - 2 plates Model CT159
Nb of Cylinders 2
Accumulated capacity kJ 19300 Displacement cm3 105
K*Ms W/°C 6,3 Standby motor
Voltage V/Ph/Fr • 400/3/50 Hz
Type of Refrigerant
Refrigerant R404A
Accessories or options
• Standby cable
Minimum number of plates on ceiling = 0
Notes
73
VATNA 200 H - B
Eutectic technology for your delivery vehicle
505 1100
Nosemount condenser weight
140 kg
440
Undermount condenser weight 553 1000
145 kg
420
Plate weight
85 kg
59 1590 30 mini
60
690
52 mm 52
-20°C -20°C
74
VATNA 200 H - B
ATP - Certificate n° BxRe1074 BxRe1072
Model VATNA 203 - 3 plates VATNA 204 - 4 plates
Accumulated capacity kJ 33500 44700
K*Ms W/°C 7,2 8,8
Notes
75
VATNA 300 H - B
Eutectic technology for your delivery vehicle
570 1250
Nosemount condenser weight
195 kg
515
500
Plate weight
85 kg
59 1590 30 mini
60
690
Plate thickness
190 mini = 800 =
52 mm
52
-20°C -20°C
VATNA 305 VATNA 306
30° C 40° C 30° C 40° C
14 m3 11 m3 17 m3 14 m3
76
VATNA 300 H - B
ATP - Certificate n° BxRe1046 BxRe1070
Model VATNA 305 - 5 plates VATNA 306 - 6 plates
Accumulated capacity kJ 55800 67000
K*Ms W/°C 11 13,4
Notes
77
VATNA 400 H - B
Eutectic technology for your delivery vehicle
195 kg
515
500
Plate weight
85 kg
59 1590 30 mini
60
690
Plate thickness
52 mm 190 mini = 800 =
52
-20°C -20°C
VATNA 407 VATNA 408
30° C 40° C 30° C 40° C
20 m3 17 m3 23 m3 19 m3
78
VATNA 400 H - B
ATP - Certificate n° BxRe1067 BxRe1063
Model VATNA 407 - 7 plates VATNA 408 - 8 plates
Accumulated capacity kJ 67200 76800
K*Ms W/°C 14,25 19,15
Notes
79
NOTES
80
Trucks
SUPRA 450
Solutions for all your distribution needs
SUPRA range performance for refrigerated trucks
1823
570
791
Benefits Sound
Model Total weight power Lwa
Constant evaporator airflow
S (Road & Standby) 340 kg 97 db
Robust design
High reliability T (Low noise) 343 kg 95 db
-20°C 0+2°C
30° C 40° C
30 m3 20 m3
33 m3 22 m3
Notes
82
SUPRA 450
ATP - Certificate n° M 748 Compressor
Diesel High Speed capacity Model TM 16
Nb of Cylinders 6
0°C / 30 ° C W 4365
Displacement cm3 163
-20°C / 30 ° C W 2515
Diesel engine
Standby capacity
Model CT2-29TV
0°C / 30 ° C W 3810
Nb of Cylinders 2
-20°C / 30 ° C W 2240
Displacement cm3 479
Airflow (constant in low / high speed) Oil change interval hrs 500 / 750
(AMCA 21085) m3/h 1590 (depends on oil, with or without bypass)
Heating Capacity Standby motor
Diesel High speed 18°C/-18°C W 1520 Standby voltage V/Ph/Fr • 230/400/3/50 Hz
Standby 18°C/-18°C W 775 • 240/460/3/60 Hz
Power (50 Hz) kW 3,6
Refrigerant
Type R404A
Charge kg 3,2
Sound pressure high speed
Standard dBA 68
Low noise dBA 66,1
Sound pressure low speed
Standard dBA 63,6
Low noise dBA 62,4
Sound pressure standby
Standard dBA 59,8
Low noise dBA 58,8
83
SUPRA 550
Solutions for all your distribution needs
SUPRA range performance for refrigerated trucks
1823
570
791
Benefits Sound
Model Total weight power Lwa
Constant evaporator airflow
S (Road & Standby) 391 kg 97 db
Robust design
High reliability T (Low noise) 394 kg 95 db
-20°C 0+2°C
30° C 40° C
35 m3 24 m3
44 m3 31 m3
Notes
84
SUPRA 550
ATP - Certificate n° M 692 Compressor
Diesel High Speed capacity Model O5K2
Nb of Cylinders 2
0°C / 30 ° C W 5455
Displacement cm3 200
-20°C / 30 ° C W 3165
Diesel engine
Standby capacity
Model CT2-29TV
0°C / 30 ° C W 4670
Nb of Cylinders 2
-20°C / 30 ° C W 2770
Displacement cm3 479
Airflow (constant in low / high speed) Oil change interval hrs 500 / 750
(AMCA 21085) m3/h 2150 (depends on oil, with or without bypass)
Heating Capacity Standby motor
Diesel High speed 18°C/-18°C W 1940 Standby voltage V/Ph/Fr • 230/400/3/50 Hz
Standby 18°C/-18°C W 1205 • 240/460/3/60 Hz
Power (50 Hz) kW 3,6
Refrigerant
Type R404A
Charge kg 4
Sound pressure high speed
Standard dBA 68
Low noise dBA 66,1
Sound pressure low speed
Standard dBA 63,6
Low noise dBA 62,4
Sound pressure standby
Standard dBA 59,8
Low noise dBA 58,8
85
SUPRA 750
Solutions for all your distribution needs
SUPRA range performance for refrigerated trucks
1823
644
856
Benefits Sound
Model Total weight power Lwa
Constant evaporator airflow
S (Road & Standby) 429 kg 97 db
Robust design
High reliability T (Low noise) 432 kg 95 db
Extreme low-noise capabilities X (Silent) 437 kg 94 db
-20°C 0+2°C
30° C 40° C
42 m3 30 m3
57 m3 38 m3
Notes
86
SUPRA 750
ATP - Certificate n° M 701 Compressor
Diesel High Speed capacity Model O5K2
Nb of Cylinders 2
0°C / 30 ° C W 6780
Displacement cm3 200
-20°C / 30 ° C W 3750
Diesel engine
Standby capacity
Model CT3-44TV
0°C / 30 ° C W 5920
Nb of Cylinders 3
-20°C / 30 ° C W 3120
Displacement cm3 719
Airflow (constant in low / high speed) Oil change interval hrs 750 / 1000
(AMCA 21085) m3/h 2140 (depends on oil, with or without bypass)
Heating Capacity Standby motor
Diesel High speed 18°C/-18°C W 2170 Standby voltage V/Ph/Fr • 230/400/3/50 Hz
Standby 18°C/-18°C W 1205 • 240/460/3/60 Hz
Power (50 Hz) kW 4,8
Refrigerant
Type R404A
Charge kg 5,2
Sound pressure high speed
Standard dBA 68,2
Low noise dBA 66,9
Silent dBA 65,8
Sound pressure low speed
Standard dBA 66
Low noise dBA 63,3
Silent dBA 62,6
Sound pressure standby
Standard dBA 59,7
Low noise dBA 57,7
87
SUPRA 850
Solutions for all your distribution needs
SUPRA range performance for refrigerated trucks
1823
644
856
Benefits Sound
Model Total weight power Lwa
Constant evaporator airflow
S (Road & Standby) 461 kg 98 db
Robust design
High reliability T (Low noise) 464 kg 95 db
Extreme low-noise capabilities X (Silent) 466 kg 92 db
-20°C 0+2°C
30° C 40° C
55 m3 43 m3
66 m3 48 m3
Notes
88
SUPRA 850
ATP - Certificate n° M 649 Compressor
Diesel High Speed capacity Model O5K4
Nb of Cylinders 4
0°C / 30 ° C W 7800
Displacement cm3 400
-20°C / 30 ° C W 4900
Diesel engine
Standby capacity
Model CT3-44TV
0°C / 30 ° C W 6450
Nb of Cylinders 3
-20°C / 30 ° C W 4240
Displacement cm3 719
Airflow (constant in low / high speed) Oil change interval hrs 750 / 1000
(AMCA 21085) m3/h 2500 (depends on oil, with or without bypass)
Heating Capacity Standby motor
Diesel High speed 18°C/-18°C W 3360 Standby voltage V/Ph/Fr • 230/400/3/50 Hz
Standby 18°C/-18°C W 1765 • 240/460/3/60 Hz
Power (50 Hz) kW 4,8
Refrigerant
Type R404A
Charge kg 6,8
Sound pressure high speed
Standard dBA 68,7
Low noise dBA 66
Silent dBA 64,6
Sound pressure low speed
Standard dBA 66,3
Low noise dBA 62,1
Silent dBA 61,9
Sound pressure standby
Standard dBA 59,7
Low noise dBA 55
89
SUPRA 950
Solutions for all your distribution needs
SUPRA range performance for refrigerated trucks
1995
699
940
Benefits Sound
Model Total weight power Lwa
Constant evaporator airflow
S (Road & Standby) 596 kg 98 db
Robust design
High reliability T (Low noise) 599 kg 96 db
Extreme low-noise capabilities X (Silent) 603 kg 94 db
High cooling performance
-20°C 0+2°C
30° C 40° C
75 m3 55 m3
88 m3 61 m3
Notes
90
SUPRA 950
ATP - Certificate n° M 637 Compressor
Diesel High Speed capacity Model O5G
Nb of Cylinders 6
0°C / 30 ° C W 10600
Displacement cm3 600
-20°C / 30 ° C W 6600
Diesel engine
Standby capacity
Model CT3-69TV
0°C / 30 ° C W 9920
Nb of Cylinders 3
-20°C / 30 ° C W 6280
Displacement cm3 1123
Airflow (constant in low / high speed) Oil change interval hrs 1000
(AMCA 21085) m3/h 2650 Standby motor
Heating Capacity Standby voltage V/Ph/Fr • 230/400/3/50 Hz
Diesel High speed 18°C/-18°C W 3945 • 240/460/3/60 Hz
Standby 18°C/-18°C W 2370 Power (50 Hz) kW 9
Refrigerant
Type R404A
Charge kg 6,8
Sound pressure high speed
Standard dBA 69,6
Low noise dBA 68,4
Silent dBA 65,4
Sound pressure low speed
Standard dBA 67,2
Low noise dBA 66,1
Silent dBA 62,4
Sound pressure standby
Standard dBA 61,5
Low noise dBA 62,1
Silent dBA 59,9
91
SUPRA 850 U
Compact undermount Diesel truck unit, combining high cooling capacities with
robust reliability
1841
602
647
Evaporator Weight
-20°C 0+2°C 52 kg
30° C 40° C 752
53 m3 42 m3 1450
64 m3 47 m3
219
weight : 52 kg
Notes
92
SUPRA 850 U
ATP - Certificate n° M 656 Compressor
Diesel High Speed capacity Model O5K4
Nb of Cylinders 4
0°C / 30 ° C W 7690
Displacement cm3 400
-20°C / 30 ° C W 4600
Diesel engine
Standby capacity
Model CT3-44TV
0°C / 30 ° C W 6550
Nb of Cylinders 3
-20°C / 30 ° C W 3975
Displacement cm3 719
Airflow (constant in low / high speed) Oil change interval hrs 750
(AMCA 21085) m3/h 2840 Standby motor
Heating Capacity Standby voltage V/Ph/Fr • 400/3/50 Hz
Diesel High speed 18°C/-18°C W 3360 Power (50 Hz) kW 5
Standby 18°C/-18°C W 1765
Refrigerant
Type R404A
Charge kg 6,8
Sound pressure high speed
Standard dBA 68,2
93
SUPRA 950 U
Extremely powerful, undermount diesel truck unit, combining exceptional cooling
capacities with robust reliability
1972
651
725
Evaporator Weight
-20°C 0+2°C
52 kg
30° C 40° C
752
65 m3 52 m3 1450
80 m3 58 m3
219
weight : 52 kg
Notes
94
SUPRA 950 U
ATP - Certificate n° M 654 Compressor
Diesel High Speed capacity Model O5G
Nb of Cylinders 6
0°C / 30 ° C W 10600
Displacement cm3 600
-20°C / 30 ° C W 6205
Diesel engine
Standby capacity
Model CT3-69TV
0°C / 30 ° C W 7430
Nb of Cylinders 3
-20°C / 30 ° C W 5500
Displacement cm3 1123
Airflow (constant in low / high speed) Oil change interval hrs 1000
(AMCA 21085) m3/h 2840 Standby motor
Heating Capacity Standby voltage V/Ph/Fr • 400/3/50 Hz
Diesel High speed 18°C/-18°C W 3960 Power (50 Hz) kW 9
Standby 18°C/-18°C W 2390
Refrigerant
Type R404A
Charge kg 6,8
Sound pressure high speed
Standard dBA 76,8
Sound pressure low speed
Standard dBA 73,7
Sound pressure standby
Standard dBA 66,1
95
SUPRA 750 SW
Unit specifically designed for swap body applications, as used in rail/road combined
transport
1735 705
627
Body opening : L 1245 x H 310 mm
Benefits Sound
Model Total weight power Lwa
Lower dimensions unit
T (Low noise) 442 kg 97 db
Maximum component accessibility
Dedicated accessories
Exceptional reliability and performance of
SUPRA
-20°C 0+2°C
30° C 40° C
42 m3 30 m3
57 m3 38 m3
Notes
96
SUPRA 750 SW
ATP - Certificate n° M 701 Compressor
Diesel High Speed capacity Model O5K2
Nb of Cylinders 2
0°C / 30 ° C W 6780
Displacement cm3 200
-20°C / 30 ° C W 3750
Diesel engine
Standby capacity
Model CT3-44TV
0°C / 30 ° C W 5920
Nb of Cylinders 3
-20°C / 30 ° C W 3120
Displacement cm3 719
Airflow (constant in low / high speed) Oil change interval hrs 750 / 1000
(AMCA 21085) m3/h 2135 (depends on oil, with or without bypass)
Heating Capacity Standby motor
Diesel High speed 18°C/-18°C W 2170 Standby voltage V/Ph/Fr • 230/400/3/50 Hz
Standby 18°C/-18°C W 1205 • 240/460/3/60 Hz
Power (50 Hz) kW 4,5
Refrigerant
Type R404A
Charge kg 5,2
97
SUPRA 900 CITY Z
Zero-engine refrigeration unit for urban distribution by truck, featuring reduced
emissions and low noise
1823
644
856
Benefits Sound
Model Total weight power Lwa
SUPRA range benefits
S (Road & Standby) 420 kg 86 db
Low emissions and noise
Constant cooling capacity
Constant evaporator airflow
Zero engine emission
-20°C 0+2°C
30° C 40° C
56 m3 44 m3
80 m3 51 m3
Notes
98
SUPRA 900 CITY Z
ATP - Certificate n° M 652 Compressor
Road capacity Model O5K4
Nb of Cylinders 4
0°C / 30 ° C W 9000
Displacement cm3 400
-20°C / 30 ° C W 5050
Standby motor
Standby capacity
Standby voltage V/Ph/Fr • 230/400/3/50 Hz
0°C / 30 ° C W 7150
• 240/460/3/60 Hz
-20°C / 30 ° C W 4150
Power (50 Hz) kW 4,8
Airflow (constant in low / high speed)
(AMCA 21085) m3/h 2500 Refrigerant
Heating Capacity Type R404A
Diesel High speed 18°C/-18°C W 3360 Charge kg 6,8
Standby 18°C/-18°C W 1765 Sound pressure high speed
Standard dBA 61
99
SUPRA 1000 CITY Z
Zero-engine refrigeration unit for urban distribution by truck, featuring reduced
emissions and low noise
1995
699
940
Benefits Sound
Model Total weight power Lwa
SUPRA range benefits
S (Road & Standby) 525 kg 88 db
Low emissions and noise
Constant cooling capacity
Constant evaporator airflow
Zero engine emission
-20°C 0+2°C
30° C 40° C
75 m3 55 m3
88 m3 61 m3
Notes
100
SUPRA 1000 CITY Z
ATP - Certificate n° - Compressor
Road capacity Model O5G
Nb of Cylinders 6
0°C / 30 ° C W 10600
Displacement cm3 600
-20°C / 30 ° C W 6600
Standby motor
Standby capacity
Standby voltage V/Ph/Fr • 230/400/3/50 Hz
0°C / 30 ° C W 9920
• 240/460/3/60 Hz
-20°C / 30 ° C W 6280
Power (50 Hz) kW 9
Airflow (constant in low / high speed)
(AMCA 21085) m3/h 2650 Refrigerant
Heating Capacity Type R404A
Diesel High speed 18°C/-18°C W 3945 Charge kg 6,8
Standby 18°C/-18°C W 2370 Sound pressure high speed
Standard dBA 63
101
OASIS 150
Tough outside, cool inside
Specially designed to meet the challenges raised by high ambient temperatures
1823
555
791
Benefits Sound
Model Total weight power Lwa
Constant evaporator airflow
S (Road & Standby) 391 kg 98 db
High ambient designed
Maintenance friendly operation
-20°C 0+2°C
40° C 50° C
19 m3 12 m3
27 m3 19 m3
Notes
102
OASIS 150
Diesel High Speed capacity Compressor
0°C / 30 ° C W 5000 Model O5K2
-20°C / 30 ° C W 2600 Nb of Cylinders 2
Standby capacity Displacement cm3 200
0°C / 30 ° C W 4070 Diesel engine
-20°C / 30 ° C W 2000 Model CT2-29TV
Airflow (constant in low / high speed) Nb of Cylinders 2
Displacement cm3 479
(AMCA 21085) m3/h 2250
Oil change interval hrs 500 / 750
Heating Capacity (depends on oil, with or without bypass)
Diesel High speed 18°C/-18°C W 1280 Standby motor
Standby 18°C/-18°C W 800
Standby voltage V/Ph/Fr • 230/400/3/50 Hz
• 240/460/3/60 Hz
Refrigerant Power (50 Hz) kW 3,6
Type R404A
Charge kg 4
Sound pressure high speed
Standard dBA 69
103
OASIS 250
Tough outside, cool inside
Specially designed to meet the challenges raised by high ambient temperatures
1823
629
856
Benefits Sound
Model Total weight power Lwa
Constant evaporator airflow
S (Road & Standby) 429 kg 101 db
High ambient designed
Maintenance friendly operation
-20°C 0+2°C
40° C 50° C
28 m3 21 m3
31 m3 24 m3
Notes
104
OASIS 250
Diesel High Speed capacity Compressor
0°C / 30 ° C W 5800 Model O5K2
-20°C / 30 ° C W 3600 Nb of Cylinders 2
Standby capacity Displacement cm3 200
0°C / 30 ° C W 4440 Diesel engine
-20°C / 30 ° C W 2840 Model CT3-44TV
Airflow (constant in low / high speed) Nb of Cylinders 3
Displacement cm3 719
(AMCA 21085) m3/h 2250
Oil change interval hrs 750 / 1000
Heating Capacity (depends on oil, with or without bypass)
Diesel High speed 18°C/-18°C W 1430 Standby motor
Standby 18°C/-18°C W 800
Standby voltage V/Ph/Fr • 230/400/3/50 Hz
• 240/460/3/60 Hz
Refrigerant Power (50 Hz) kW 4,8
Type R404A
Charge kg 5,2
Sound pressure high speed
Standard dBA 72
105
OASIS 350
Tough outside, cool inside
Specially designed to meet the challenges raised by high ambient temperatures
1995
684
940
Benefits Sound
Model Total weight power Lwa
Constant evaporator airflow
S (Road & Standby) 596 kg 99 db
High ambient designed
High refrigeration capacity
Maintenance friendly operation
-20°C 0+2°C
40° C 50° C
54 m3 40 m3
59 m3 47 m3
Notes
106
OASIS 350
Diesel High Speed capacity Compressor
0°C / 30 ° C W 10300 Model O5G
-20°C / 30 ° C W 6400 Nb of Cylinders 6
Standby capacity Displacement cm3 600
0°C / 30 ° C W 9600 Diesel engine
-20°C / 30 ° C W 5800 Model CT3-69TV
Airflow (constant in low / high speed) Nb of Cylinders 3
Displacement cm3 1123
(AMCA 21085) m3/h 2770
Oil change interval hrs 1000
Heating Capacity
Standby motor
Diesel High speed 18°C/-18°C W 3945
Standby voltage V/Ph/Fr • 230/400/3/50 Hz
Standby 18°C/-18°C W 2370
• 240/460/3/60 Hz
Power (50 Hz) kW 9
Refrigerant
Type R404A
Charge kg 6,8
Sound pressure high speed
Standard dBA 70
107
SUPRA 750 MT
Total flexibility for multi-product deliveries with ultra-slim evaporators that can be
adapted to large configuration requirement
1823
644
856
Body opening : L 90 x H 90 mm
-20°C
30° C 40° C
35 m3 25 m3
Notes
108
SUPRA 750 MT
ATP - Certificate n° M 599
Nominal capacity at -20°C / 30°C 3570 W
Evaporator MTS 700 MTS 1100 MTS 1450
Diesel High Speed capacity
0°C / 30 ° C W 5050 5650 5950
-20°C / 30 ° C W 2900 3200 3500
Standby capacity
0°C / 30 ° C W 4610 5390 5645
-20°C / 30 ° C W 2755 3135 3460
Airflow (constant in low / high speed)
(AMCA 21085) m3/h 1100 2200 2500
Heating Capacity
Diesel High speed 18°C/-18°C W 2940 3120 3300
Standby 18°C/-18°C W 2855 3080 3275
Compressor Refrigerant
Model O5K2 Type R404A
Nb of Cylinders 2 Charge Depending on configuration
3
Displacement cm 200 Sound pressure high speed
Diesel engine Standard dBA 68,2
Model CT3-44TV Low noise dBA 66,9
Nb of Cylinders 3 Silent dBA 65,8
Displacement cm3 719 Sound pressure low speed
Oil change interval hrs 750 / 1000 (depends
Standard dBA 66
on oil, with or without bypass)
Low noise dBA 63,3
Standby motor Silent dBA 62,6
Standby voltage V/Ph/Fr • 230/400/3/50 Hz Sound pressure standby
Power (50 Hz) kW 4,8
Standard dBA 59,7
Low noise dBA 57,7
109
SUPRA 750 MT
MTS 700 MTS 1450
700 752
1450
752
200
200
23 kg 42 kg
MTS 1100
752 1044
200
34 kg
110
SUPRA 750 MT
System 1 System 4
700
700
1450
1450
1450
< 6.5 m* < 6.5 m*
1100
1100
System 3 System 6
700
1450
700
700
< 2 m* < 6 m*
< 6.5 m*
Consult us
(*) Compartment lengths are given for 30°C ambient temperature, -20°C compartment temperature.
Other configurations are available upon request.
111
SUPRA 850 MT
Total flexibility for multi-product deliveries with ultra-slim evaporators that can be
adapted to large configuration requirement
1823
644
856
Body opening : L 90 x H 90 mm
-20°C
30° C 40° C
40 m3 30 m3
Notes
112
SUPRA 850 MT
ATP - Certificate n° M 647
Nominal capacity at -20°C / 30°C 4250 W
Evaporator MTS 700 MTS 1100 MTS 1450
Diesel High Speed capacity
0°C / 30 ° C W 5400 6120 6615
-20°C / 30 ° C W 2975 3705 4075
Standby capacity
0°C / 30 ° C W 5090 5650 5845
-20°C / 30 ° C W 2875 3530 3880
Airflow (constant in low / high speed)
(AMCA 21085) m3/h 1100 2200 2500
Heating Capacity
Diesel High speed 18°C/-18°C W 2985 3425 3645
Standby 18°C/-18°C W 2925 3320 3530
Compressor Refrigerant
Model O5K4 Type R404A
Nb of Cylinders 4 Charge Depending on configuration
3
Displacement cm 400 Sound pressure high speed
Diesel engine Standard dBA 68,7
Model CT3-44TV Low noise dBA 66
Nb of Cylinders 3 Silent dBA 64,6
Displacement cm3 719 Sound pressure low speed
Oil change interval hrs 750 / 1000 (depends
Standard dBA 66,3
on oil, with or without bypass)
Low noise dBA 62,1
Standby motor Silent dBA 61,9
Standby voltage V/Ph/Fr • 230/400/3/50 Hz Sound pressure standby
Power (50 Hz) kW 5
Standard dBA 59,7
Low noise dBA 55
113
SUPRA 850 MT
700 752
1450
752
200
200
23 kg 42 kg
MTS 1100
752 1044
200
34 kg
114
SUPRA 850 MT
System 1 System 4
700
700
1450
1450
1450
< 7.5 m* < 7.5 m*
System 2 System 6
700
1450
700
1100
700
6000 m3/h
System 3
1450
700
< 2 m*
< 7.5 m*
Consult us
(*) Compartment lengths are given for 30°C ambient temperature, -20°C compartment temperature.
Other configurations are available upon request.
115
SUPRA 950 MT
Total flexibility for multi-product deliveries with ultra-slim evaporators that can be
adapted to large configuration requirement
1995
699
940
-20°C
30° C 40° C
60 m3 50 m3
Notes
116
SUPRA 950 MT
ATP - Certificate n° M 708
Nominal capacity at -20°C / 30°C 5865 W
Evaporator MTS 700 MTS 1100 MTS 1450 MTS 2200 MTD 1450 MTD 2200
Diesel High Speed capacity
0°C / 30 ° C W 6335 8150 9355 9375 9885 9985
-20°C / 30 ° C W 3495 4360 5330 5130 5390 5675
Standby capacity
0°C / 30 ° C W 5925 8100 9215 9200 9540 9680
-20°C / 30 ° C W 3525 4420 5300 5245 5370 5750
Airflow (constant in low / high speed)
(AMCA 21085) m3/h 1100 2200 2500 3500 2600 3800
Heating Capacity
Diesel High speed 18°C/-18°C W 4500 5015 5600 5480 5635 5805
Standby 18°C/-18°C W 4515 5052 5580 5545 5620 5850
Compressor Refrigerant
Model O5G Type R404A
Nb of Cylinders 6 Charge Depending on configuration
3
Displacement cm 600 Sound pressure high speed
Diesel engine Standard dBA 69,6
Model CT3-69TV Low noise dBA 68,4
Nb of Cylinders 3 Silent dBA 65,4
Displacement cm3 1123 Sound pressure low speed
Oil change interval hrs 1000
Standard dBA 67,2
Standby motor Low noise dBA 66,1
Standby voltage V/Ph/Fr • 230/400/3/50 Hz Silent dBA 62,4
Power (50 Hz) kW 9 Sound pressure standby
Standard dBA 61,5
Low noise dBA 62,1
117
SUPRA 950 MT
MTS 700 MTD 1450
167
200
23 kg 51 kg
752 1044
944 2150
167
200
34 kg 71 kg
MTS 1450
1450
752
200
42 kg
MTS 2200
752 2150
200
60 kg
118
SUPRA 950 MT
System 1 System 4
700
700
2200
1450
1450
< 9 m* < 9 m*
System 2 System 6
700
1450
1450
700
700 6000 m3/h
1100
1100
1100
700
System 3 System 8
1100
1100
1450
700
700
< 9 m* < 9 m*
< 2 m* System 9
700
700
Extension kit
1450
119
SUPRA 950 U MT
Extremely powerful undermount diesel truck unit combining high flexibility for multi-
product deliveries with robust reliability
1972
623
631
-20°C
30° C 40° C
60 m3 50 m3
Notes
120
SUPRA 950 U MT
ATP - Certificate n° M 643
Nominal capacity at -20°C / 30°C 5590 W
Evaporator MTS 700 MTS 1100 MTS 1450 MTS 2200
Diesel High Speed capacity
0°C / 30 ° C W 5960 7815 9090 9645
-20°C / 30 ° C W 3445 4265 4780 5010
Standby capacity
0°C / 30 ° C W 5910 7795 8590 9485
-20°C / 30 ° C W 3527 4240 4710 5130
Airflow (constant in low / high speed)
(AMCA 21085) m3/h 1100 2200 2500 3500
Heating Capacity
Diesel High speed 18°C/-18°C W 4465 4960 5270 5405
Standby 18°C/-18°C W 4515 4945 5225 5480
Compressor Refrigerant
Model O5G Type R404A
Nb of Cylinders 6 Charge Depending on configuration
3
Displacement cm 600 Sound pressure high speed
Diesel engine Standard dBA 76,8
Model CT3-69TV Sound pressure low speed
Nb of Cylinders 3
Standard dBA 73,7
Displacement cm3 1123
Oil change interval hrs 1000 Sound pressure standby
Standby motor Standard dBA 66,1
Standby voltage V/Ph/Fr • 400/3/50 Hz
Power (50 Hz) kW 9
121
SUPRA 950 U MT
MTS 700 MTS 1450
700 752
1450
752
200
200
23 kg 42 kg
752 1044
752 2150
200
200
34 kg 60 kg
122
SUPRA 950 U MT
System 1 System 3
1450
2200
700
< 9 m* < 2 m*
< 9 m*
System 2 System 4
700
700
1450
1450
1450
1450
Extension kit
(*) Compartment lengths are given for 30°C ambient temperature, -20°C compartment temperature.
Other configurations are available upon request.
123
SUPRA 1000 CITY Z MT
Zero-engine refrigeration unit for urban distribution by truck, combining high
flexibility for multi-product deliveries with reduced emissions and low noise
1995
699
940
-20°C
30° C 40° C
60 m3 50 m3
Notes
124
SUPRA 1000 CITY Z MT
ATP - Certificate n° -
Nominal capacity at -20°C / 30°C 5865 W
Evaporator MTS 700 MTS 1100 MTS 1450 MTS 2200 MTD 1450 MTD 2200
Road capacity
0°C / 30 ° C W 6335 8150 9355 9375 9885 9985
-20°C / 30 ° C W 3495 4360 5330 5130 5390 5675
Standby capacity
0°C / 30 ° C W 5925 8100 9215 9200 9540 9680
-20°C / 30 ° C W 3525 4420 5300 5245 5370 5750
Airflow (constant in low / high speed)
(AMCA 21085) m3/h 1100 2200 2500 3500 2600 3800
Heating Capacity
Diesel High speed 18°C/-18°C W 4500 2615 5600 3080 5635 5805
Standby 18°C/-18°C W 4515 2650 5580 3145 5620 5850
Compressor Refrigerant
Model O5G Type R404A
Nb of Cylinders 6 Charge Depending on configuration
3
Displacement cm 600 Sound pressure high speed
Standby motor Standard dBA 63
Standby voltage V/Ph/Fr • 230/400/3/50 Hz
Power (50 Hz) kW 9
125
SUPRA 1000 CITY Z MT
MTS 700 MTD 1450
167
200
23 kg 51 kg
752 1044
944 2150
167
200
34 kg 71 kg
MTS 1450
1450
752
200
42 kg
MTS 2200
752 2150
200
60 kg
126
SUPRA 1000 CITY Z MT
System 1 System 4
700
700
2200
1450
1450
< 9 m* < 9 m*
System 2 System 6
700
2800 m3/h
1450
1450
700
700 6000 m3/h
1100
1100
1100
700
1100
1450
700
700
< 9 m* < 9 m*
*
< 2 m* System 9
Extension kit
700
700
< 2 m* < 9 m*
127
OASIS 250 MT
Tough outside, cool inside
Specially designed to meet the challenges raised by high ambient temperatures
1823
644
856
Body opening : L 90 x H 90 mm
-20°C
40° C 50° C
27 m3 20 m3
Notes
128
OASIS 250 MT
Nominal capacity at -20°C / 30°C 3380 W
Evaporator MTS 1100-L-12 MTS 1100-L-12
Diesel High Speed capacity
0°C / 30 ° C W 4750 4750
-20°C / 30 ° C W 2730 2730
Standby capacity
0°C / 30 ° C W 4331 4331
-20°C / 30 ° C W 2588 2588
Airflow (constant in low / high speed)
(AMCA 21085) m3/h 2200 2200
Heating Capacity
Diesel High speed 18°C/-18°C W 2840 2840
Standby 18°C/-18°C W 2750 2750
Compressor Refrigerant
Model O5K2 Type R404A
Nb of Cylinders 2 Charge Depending on configuration
Displacement cm3 200 Sound pressure high speed
Diesel engine Standard dBA 72
Model CT3-44TV
Nb of Cylinders 3
Displacement cm3 719
Oil change interval hrs 750 / 1000
(depends on oil, with or without bypass)
Standby motor
Standby voltage V/Ph/Fr • 230/400/3/50 Hz
Power (50 Hz) kW 4,8
129
OASIS 250 MT
MTS 1100
34 kg
130
OASIS 250 MT
1100
1100
< 4.3 m*
1100 1100
< 4.3 m*
1100
1100
< 4.3 m*
1100
1100
< 4.3 m*
(*) Compartment lengths are given for 50°C ambient temperature, -20°C compartment temperature.
131
OASIS 350 MT
Tough outside, cool inside
Specially designed to meet the challenges raised by high ambient temperatures
1995
684
940
Body opening : L 90 x H 90 mm
-20°C
40° C 50° C
53 m3 39 m3
Notes
132
OASIS 350 MT
Nominal capacity at -20°C / 30°C 5690 W
Evaporator MTS 700 MTS 1100 MTS 1450 MTS 2200 MTD 1450 MTD 2200
Diesel High Speed capacity
0°C / 30 ° C W 5630 7242 8313 8331 8784 8873
-20°C / 30 ° C W 3106 3874 4736 4559 4790 5043
Standby capacity
0°C / 30 ° C W 5265 7198 8189 8175 8478 8602
-20°C / 30 ° C W 3132 3928 4710 4661 4772 5110
Airflow (constant in low / high speed)
(AMCA 21085) m3/h 1100 2200 2500 3500 2600 3800
Heating Capacity
Diesel High speed 18°C/-18°C W 4260 2325 5240 2735 2875 5425
Standby 18°C/-18°C W 4280 2360 5225 2800 2860 5465
Compressor Refrigerant
Model O5G Type R404A
Nb of Cylinders 6 Charge Depending on configuration
Displacement cm3 600 Sound pressure high speed
Diesel engine Standard dBA 70
Model CT3-69TV
Nb of Cylinders 3
Displacement cm3 1123
Oil change interval hrs 1000
Standby motor
Standby voltage V/Ph/Fr • 230/400/3/50 Hz
Power (50 Hz) kW 9
133
OASIS 350 MT
MTS 700 MTD 1450
167
200
23 kg 51 kg
752 1044
944 2150
167
200
34 kg 71 kg
MTS 1450
1450
752
200
42 kg
MTS 2200
752 2150
200
60 kg
134
OASIS 350 MT
System 1
2200
< 8 m*
System 2
1450
1450
System 3
1450
700
< 2 m*
< 8 m*
(*) Compartment lengths are given for 50°C ambient temperature, -20°C compartment temperature.
Other configurations are available upon request.
135
NOTES
136
Trailers
MAXIMA 1000
The belt-driven technology specifically designed for draw-bar and city trailer
applications
1888
1930
Benefits Sound
Model Total weight power Lwa
High reliability
R 765 kg 101 db
Light weight
Low height unit S 795 kg 101 db
High standby capacity T 795 kg 101 db
Easy components accessibility
-20°C 0+2°C
30° C 40° C
72 m3 52 m3
85 m3 57 m3
Notes
138
MAXIMA 1000
ATP - Certificate n° M634 Compressor
Diesel High Speed capacity Model 05 K4
Nb of Cylinders 4
0°C/30°C W 10180
Displacement cm3 400
-20°C/30°C W 6100
Engine
Standby capacity
Model CT4.91 TV
0°C/30°C W 10070
Nb of Cylinders 4
-20°C/30°C W 6120
Displacement cm3 1498
Airflow Oil change interval hrs 1500
(AMCA 21085) m3/h 4200 Standby motor
Heating Capacity Voltage V/Ph/Fr • 400/3/50 Hz
Diesel High speed 18°C/-18°C W 6000 Power (50 Hz) kW 11
Standby 18°C/-18°C W 6000
Refrigerant
Type R404A
Charge kg 7
Sound pressure high speed
Standard dBA 73,5
Sound pressure standby
Standard dBA 68,3
139
MAXIMA 1300
Combines reliability and simplicity thanks to belt-driven technology
1888
2153
Benefits Sound
Model Total weight power Lwa
High reliability
R 790 kg 102 db
Light weight
High standby capacity S 815 kg 102 db
Easy components accessibility T 815 kg 102 db
-20°C 0+2°C
30° C 40° C
90 m3 80 m3
90 m3 90 m3
Notes
140
MAXIMA 1300
ATP - Certificate n° M711 Compressor
Diesel High Speed capacity Model 05 K4
Nb of Cylinders 4
0°C/30°C W 13200
Displacement cm3 400
-20°C/30°C W 7015
Engine
Standby capacity
Model CT 4.91TV
0°C/30°C W 11200
Nb of Cylinders 4
-20°C/30°C W 6380
Displacement cm3 1498
Airflow Oil change interval hrs 1500
(AMCA 21085) m3/h 4935 Standby motor
Heating Capacity Voltage V/Ph/Fr • 400/3/50 Hz
Diesel High speed 18°C/-18°C W 7000 Power (50 Hz) kW 11
Standby 18°C/-18°C W 6300
Refrigerant
Type R404A
Charge kg 7
Sound pressure high speed
Standard dBA 74,5
Low noise dBA 73
Sound pressure low speed
Standard dBA 69,6
Low noise dBA 69
Sound pressure standby
Standard dBA 68,4
Low noise dBA 67,2
141
VECTOR 1550
The best choice for fuel efficiency, combining the reliability of all-electric technology
with a low-consumption engine
2050
2227
Benefits Sound
Model Total weight power Lwa
Maximising uptime
S 739 kg 98 db
Protecting cargo
Ensuring sustainability T 745 kg 96 db
Versatility
-20°C 0+2°C
30° C 40° C
90 m3 90 m3
90 m3 90 m3
Notes
142
VECTOR 1550
ATP - Certificate n° M677 Compressor
Diesel High Speed capacity Model ZF19VE-164
Nb of Cylinders scroll
0°C/30°C W 14830
Displacement cm3 123
-20°C/30°C W 8115
Engine
Diesel Low Speed capacity
Model CT 4.91TV
0°C/30°C W 12400
Nb of Cylinders 4
-20°C/30°C W 7000
Displacement cm3 1498
Standby capacity Oil change interval hrs 1500
0°C/30°C W 12430 Generator
-20°C/30°C W 7000
Voltage V/Ph/Fr • 400/3/50 Hz
Airflow Power (50 Hz) kW 16
(AMCA 21085) m3/h 5600
Heating Capacity Refrigerant
Diesel High speed 18°C/-18°C W 8800 Type R404A
Diesel Low speed 18°C/-18°C W 5000 Charge kg 6,3
Standby 18°C/-18°C W 5000 Sound pressure high speed
Standard dBA 69,6
Sound pressure low speed
Standard dBA 66,1
143
VECTOR 1550 CITY
Enables night deliveries, improves driver and citizen comfort, with standard
installation
2050
2347
Benefits Sound
Model Total weight power Lwa
Maximising uptime
- 765 kg 95 db
Protecting cargo
Ensuring sustainability
Piek certified (60 dB sound pressure at low
speed)
-20°C 0+2°C
30° C 40° C
90 m3 90 m3
90 m3 90 m3
Notes
144
VECTOR 1550 CITY
ATP - Certificate n° M 766 Compressor
Diesel High Speed capacity Model ZF19VE-164
Nb of Cylinders scroll
0°C/30°C W 14800
Displacement cm3 123
-20°C/30°C W 8000
Engine
Diesel Low Speed capacity
Model CT 4.91TV
0°C/30°C W 11800
Nb of Cylinders 4
-20°C/30°C W 6800
Displacement cm3 1498
Standby capacity Oil change interval hrs 1500
0°C/30°C W 13000 Generator
-20°C/30°C W 7200
Voltage V/Ph/Fr • 400/3/50 Hz
Airflow Power (50 Hz) kW 16
(AMCA 21085) m3/h 5600
Heating Capacity Refrigerant
Diesel High speed 18°C/-18°C W 8800 Type R404A
Diesel Low speed 18°C/-18°C W 5000 Charge kg 6,3
Standby 18°C/-18°C W 5000 Sound pressure low speed
Standard dBA 60
145
VECTOR 1850
Gives you the muscle you need to master the cold chain
2050
2227
Benefits Sound
Model Total weight power Lwa
Maximising uptime
S 937 kg 103 db
Protecting cargo
Ensuring sustainability T 943 kg 101 db
Intensive use
-20°C 0+2°C
30° C 40° C
95 m3 95 m3
95 m3 95 m3
Notes
146
VECTOR 1850
ATP - Certificate n° M633 Compressor
Diesel High Speed capacity Model 06D41
Nb of Cylinders 6
0°C/30°C W 18000
Displacement cm3 660
-20°C/30°C W 9600
Engine
Diesel Low Speed capacity
Model CT 4.134DI
0°C/30°C W 13530
Nb of Cylinders 4
-20°C/30°C W 8270
Displacement cm3 2200
Standby capacity Oil change interval hrs 1500
0°C/30°C W 14960 Generator
-20°C/30°C W 9010
Voltage V/Ph/Fr • 400/3/50 Hz
Airflow Power (50 Hz) kW 23
(AMCA 21085) m3/h 5600
Heating Capacity Refrigerant
Diesel High speed 18°C/-18°C W 9000 Type R404A
Diesel Low speed 18°C/-18°C W 5200 Charge kg 6,3
Standby 18°C/-18°C W 5000 Sound pressure high speed
Standard dBA 75,8
Low noise dBA 72,8
Sound pressure low speed
Standard dBA 71,6
Low noise dBA 67,3
Sound pressure standby
Standard dBA 67,8
147
VECTOR E
Electric only unit provides a powerful, low noise solution for cold storage
temperature control
2050
2227
Benefits Sound
Model Total weight power Lwa
Maximising uptime
R 637 kg 94 db
Protecting cargo
Ensuring sustainability
Standby use only
-20°C 0+2°C
30° C 40° C
90 m3 90 m3
90 m3 90 m3
Notes
148
VECTOR E
Standby capacity Compressor
0°C/30°C W 15000 Model 06D41
-20°C/30°C W 8500 Nb of Cylinders 6
Airflow Displacement cm3 660
3
(AMCA 21085) m /h 4400
Heating Capacity Refrigerant
Standby 18°C/-18°C W 5800 Type R404A
Charge kg 6,3
Sound pressure standby
Standard dBA 68
149
ULTRA XL
Unit for 32 pallets trailer designed for maximum performance and reliability
1846
2146
546
Body opening : L 1697 x H1168 mm
Benefits Sound
Model Total weight power Lwa
High capacity
R 759 kg 102 db
Proven performance
Reliable in high-ambient conditions S 845 kg 102 db
-20°C 0+2°C
30° C 40° C
95 m3 95 m3
95 m3 95 m3
Notes
150
ULTRA XL
ATP - Certificate n° M666 Compressor
Diesel High Speed capacity Model O5G
Nb of Cylinders 6
0°C/30°C W 17100
Displacement cm3 644
-20°C/30°C W 10250
Engine
Airflow
3
Model CT4-134 TV
(AMCA 21085) m /h 4800
Nb of Cylinders 4
Heating Capacity Displacement cm3 2230
Diesel High speed 18°C/-18°C W 10200 Oil change interval hrs 3000
Standby motor
Refrigerant Voltage V/Ph/Fr • 400/3/60 Hz
Type R404A Power (50 Hz) kW 13
Charge kg 9,1
151
X2100A
Exceptional temperature control with a new dimension in performance
1940
2177
Benefits Sound
Model Total weight power Lwa
Robust design
R 744 kg 102 db
Outstanding capacity and airflow
Low life cycle cost
Modern aerodynamic design
-20°C 0+2°C
30° C 40° C
95 m3 95 m3
95 m3 95 m3
Notes
152
X2100A
Diesel High Speed capacity Compressor
0°C/30°C W 19640 Model O5G
-20°C/30°C W 9980 Nb of Cylinders 6
Airflow Displacement cm3 644
(AMCA 21085) 3
m /h 5700 Engine
Heating Capacity Model CT4-134 TV
Nb of Cylinders 4
Diesel High speed 18°C/-18°C W 9900
Displacement cm3 2230
Oil change interval hrs 3000
Refrigerant
Type R404A
Charge kg 9,1
153
SOLARA
Designed for maximum heating capacity in extremely cold climates
459 1067
845
Benefits Sound
Model Total weight power Lwa
Maximum cargo protection
R 200 kg 97 db
Compact design
High resistance material
+6 +8°C
30° C
90 m3
Notes
154
SOLARA
Airflow Engine
(AMCA 21085) m3/h 5400 Model CT 2.29TV
Heating Capacity Nb of Cylinders 2
Displacement cm3 480
Diesel High speed 18°C/-18°C W 8800
Oil change interval hrs 750
155
MAXIMA 1300 MT
The belt-driven technology applied for multi-temperature application
1888
2162
Benefits Sound
Model Unit weight power Lwa
High reliability
S 815 kg 102 db
High standby capacity
Easy components accessibility
Affordable multi-temperature product
-20°C
30° C 40° C
90 m3 75 m3
Notes
156
MAXIMA 1300 MT
ATP - Certificate n° M588
Nominal capacity at -20°C / 30°C 7070 W
Evaporator principal MMS 700 MMS 1100 MMS 2200
Diesel High Speed capacity
0°C/30°C W 13160 6260 8130 11200
-20°C/30°C W 7070 3630 4325 5340
Standby capacity
0°C/30°C W 11670 6095 8080 10400
-20°C/30°C W 6500 3540 4305 5355
Airflow
(AMCA 21085) m3/h 4930 1000 2000 3500
Heating Capacity
Diesel High speed 18°C/-18°C W 7070 6030 7325 8340
Standby 18°C/-18°C W 6500 5940 7305 8355
Compressor Refrigerant
Model 05 K4 Type R404A
Nb of Cylinders 4 Charge Depending on configuration
3
Displacement cm 400 Sound pressure high speed
Engine Standard dBA 74,5
Model CT 4.91TV Sound pressure low speed
Nb of Cylinders 4
Standard dBA 69,6
Displacement cm3 1498
Oil change interval hrs 1500 Sound pressure standby
Standby motor Standard dBA 68,4
Voltage V/Ph/Fr • 400/3/50 Hz
Power (50 Hz) kW 11
157
MAXIMA 1300 MT
700
752 752 2150
200
200
23 kg 60 kg
MMS 1100
752 1044
200
34 kg
158
MAXIMA 1300 MT
System 1
2200
< 11 m*
System 3
1100
< 7 m*
System 4
700
< 10 m*
System 5
1100
(*) Compartment lengths are given for 30°C ambient temperature, -20°C compartment temperature.
Other configurations are available upon request.
159
VECTOR 1850 MT
The best choice for powerful refrigeration, combining huge capacity with a wide
range of evaporators
2050
2227
Benefits Sound
Model Unit weight power Lwa
Maximising uptime
S 955 kg 103 db
Protecting cargo
Ensuring sustainability T 961 kg 101 db
Large choice of evaporators
-20°C
30° C 40° C
95 m3 95 m3
Notes
160
VECTOR 1850 MT
ATP - Certificate n° M595
Nominal capacity at -20°C / 30°C 9500 W
Evaporator principal MVS700 MVS 1100 MVS 2200 MVD 1100 MVD 2200
Diesel High Speed capacity
0°C/30°C W 18030 7520 8840 13560 10540 15395
-20°C/30°C W 9500 4400 4700 7300 6000 7950
Standby capacity
0°C/30°C W 14320 6910 8315 12965 10395 14655
-20°C/30°C W 8845 4370 4655 6865 5635 7705
Airflow
(AMCA 21085) m3/h 5520 1035 2075 3500 2305 3805
Heating Capacity
Diesel High speed 18°C/-18°C W 9500 3000 4500 7500 6000 7500
Standby 18°C/-18°C W 8845 3000 4500 7500 6000 7500
Compressor Refrigerant
Model O6D Type R404A
Nb of Cylinders 6 Charge Depending on configuration
3
Displacement cm 660 Sound pressure high speed
Engine Standard dBA 75,8
Model CT 4.134DI Low noise dBA 72,8
Nb of Cylinders 4 Sound pressure low speed
Displacement cm3 2200
Standard dBA 71,6
Oil change interval hrs 1500
Low noise dBA 67,3
Generator
Sound pressure standby
Voltage V/Ph/Fr • 400/3/50 Hz
Standard dBA 67,8
Power (50 Hz) kW 23
161
VECTOR 1850 MT
MVS 700 MVD 1100
167
200
23 kg 40 kg
MVD 2200
MVS 1100
34 kg 71 kg
MVS 2200
752 2150
200
60 kg
162
VECTOR 1850 MT
System 1 System 3
2200
700
< 11 m* < 10 m*
System 1 bis System 3 bis
2200
700
700
< 11 m*
System 2 System 4
1100
1100
1100
2200
1100
System 6
(*) Compartment lengths are given for 30°C ambient
700
6000 m3/h
< 9 m*
163
NOTES
164
Electronics
LogiCOLD
Along to its internal memory that records technical data for about 2 months
(depending on settings of internal memory), LogiCOLD brings 20 years of
refrigeration experience with its exclusive software features
Benefits
Easier maintenance
Personalized settings
Product oriented operation
Energy saving operation
Pretrip
Keypad lock
Product specifications
Standard equipment
• Embedded software on VECTOR families
• Intelliset
• Opticold / Ecofuel
• Productshield
• Range protect
• Sleep mode
Accessories or options
• Fuel / door sensors logic
Notes
167
EasyCOLD
EasyCOLD is the easy to use straight forward intelligence of MAXIMA & SUPRA
families
Notes
168
DataCOLD 250
Bring visibility and control to your Cold Chain with the DataCOLD range, temperature
recorders for refrigerated transport
Benefits
Cold chain alarm management
Thermal printer
Notes
169
DataCOLD 500
Bring visibility and control to your Cold Chain with the DataCOLD range, temperature
recorders for refrigerated transport
Benefits
Cold chain alarm management
Thermal printer
Product specifications Communication to telematics providers
• Sensors
4 sensors (temperature or humidity) Standard equipment
4 digital inputs (to record door openings) • 1 power supply
2 digital outputs (to enable alarms lights) • 2 Temperature sensors
• Memory size and settings • Thermal printer
512 KBYTES (1 year record with 4 sensors @
15 min interval)
1-60 minutes adjustable logging interval Accessories or options
• Display and keypad • Extra sensors :
LCD screen background-lit, 122x32 dots - genuine temperature sensor
4 coloured soft keys for ease of use - handheld temperature sensor
• Thermal printer - product inertia temperature sensor
• Languages - humidity sensor
English, French, Dutch, German, Italian, • Communication cable to computer :
Spanish, Portuguese, Swedish, Danish, - Infra red
Hungarian, Slovakian, Finnish, Slovenian - RS232
• Dimensions • Telecommunication:
500 T (Trailer): 225x185x112 mm - COLDTrans or local Carrier telematics
500 R (Radio format): DIN size - communication to other telematics providers
(186x58x148 mm)
Variants
Regulation
• R model (DIN format) for instalation in-cab
Compliant with the European regulation for • T model for outside trailer installation
transport of frozen food (EN12830) • Dummy printer
Notes
170
COLDTrans
COLDTrans, the GPRS communications feature within DataCOLD, allows remote and
real-time management of temperature-controlled trucks and trailers
Benefits
Dedicated cold chain management solution
Constant reporting to website
Data capture when no GPRS coverage
Standard equipment
Product specifications
• Magnetic or windshield antenna
• Real time temperature & set point
• SIM Cards (if Carrier European roaming)
information
• Refrigeration unit operation monitoring
• Real time GPS position information Accessories or options
• Remote cold chain management & alarms
• Automatic SMS or Email alert service
• Multi-lingual website
• European cartography Service
• Portal self-administration
• Excel or PDF preset report Service
• Customizable graphics & reports
• Windshield or window patch antenna
• GPRS / GSM operated SIM cards
• Personnalized Excel & Pdf report
• SMS alarm system Variants
• Geofencing
• SIM cards subscription options :
- Carrier European roaming
- Local subscription
- Own SIM cards usage
Regulation
Compliant with the European regulation for
transport of frozen food (EN12830)
Notes
171
COLDTouch
With COLDTouch, an in-cab wireless screen, go forward, keep an eye on the
sensitive trailer box information and serenely drive your load to destination,
everywhere in EMEA & the Americas
Variants
• with temperature sensor inputs
Notes
172
Light bar
The auto-dimming LED light bar uses high visibility LEDs and provides a wide
viewing angle, which makes it optimal for both driver’s view and distribution
operations where long distance yard view is required
Benefits
Wide viewing angle
Long distance yard view
Standard equipment
• Power & VECTOR unit communication cable
Accessories or options
• MAXIMA unit communication cable
Product specifications
• Green & amber lights indicate « OK » & «
NOK »
• High visibility with wide viewing angle
• LED technology
• Bracket or front wall mounting
• Auto dimming
• Low energy consumption
Notes
173
Remote panel
With the remote panel, control your Carrier unit from the back of the trailer or another
remote location of your choice
Benefits
Ease of use
Bright display
Standard equipment
• Power & Carrier unit communication cable
Variants
• Flush mounted (retrofit application)
Product specifications • Surface mounted ( bodybuilder application)
• 1/2/3 compartments
• Turn On/Off compartments
• Change setpoints
• Monitor temperature
• Lock display
• Sleeper mode
• Flush mounted dimensions (H x W x D) in
mm: 244,5 x 200 x 30
• Surface mounted dimensions in mm
160 x 210 x 36
• Available in Celsius & Fahrenheit degree
Notes
174
Sensor monitor
The Dual-View Temperature Display is an effective way to independently monitor a
trailer’s box temperature on the road or in the yard
Benefits
Reverse image option
High visibility amber LED display
Auto-dimming
Scrolling multitemperature information
Standard equipment
•1 temperature sensor
Accessories or options
Product specifications
• Power & Carrier unit communication cable
• Independent temperature monitoring
– Display up to 3 temperature zones in ºC or
Variants
ºF
• Reefer unit status when connected • UK model
– Cool (C), Heat (H), Defrost (F), or Warning (8)
• Driver-friendly design
– Reverse image option for mirror viewing
– Straight image for yard monitoring
– High visibility amber LED display
– Auto-dimming
• Compatible with most Carrier Transicold and
Thermo King trailer units
Notes
175
Datashare
Datashare is a card that plugs in the control box and downloads automatically the
internal memory of your VECTOR unit
Benefits
An easy way to retrieve the last 2 months of
information datas when you are on the road
Product specifications
• PCMCIA cards (needs TRU-Tech or TRU-
View)
Notes
176
Datatrack
Datatrack enables the monitoring of your refrigeration unit through your preferred
telematics provider (to know what telematic provider is approved, contact Carrier
Transicold)
Benefits
Have the best of both worlds: a coldchain
leader & fleet management experts
Product specifications
• Refrigeration unit operating mode
• Alarms
• Defrost
• Maintenance hours
• Temperatures (setpoint & return air)
• Fuel level (if equipped with fuel level sensor)
• Battery voltage
Notes
177
TRUTech
TRUTech is an efficient PC tool that will help the local Carrier service center to
analyse your refrigeration unit to perform the best maintenance
Benefits
Designed by Carrier Transicold’s engineers,
TRUTech is compatible with all Truck & Trailer
units
Variants
TRUView is a lighter version of TRUTech,
available for our customers who want to
perform part of the maintenance themselves
Product specifications
• Windows XP, Vista and 7 (32 & 64 bits)
Notes
178
Fuel sensor
This sensor is connected to the VECTOR and display the fuel level and trigger alarms
when the level is too low
Benefits
Never run low on fuel
Standard equipment
• Power & Carrier unit communication cable
Variants
• Carrier tank
• Other tanks’ brands are available, please
Product specifications consult us.
Capacitive sensor
Notes
179
NOTES
180
Our company is constantly seeking to improve the quality of its products and,
therefore, reserves the right to modify its products without prior notice.
© Carrier Corporation – Carrier Transicold Europe S.C.S. au capital de 16 090 700 euros – R.C.S. Nanterre 410 041 776
Code APE 4669B – VAT: FR52410041776 – The information contained in this document is not contractually binding, and may not be reproduced without prior approval.
Printed in France (05-12) 62-61782-20.