Professional Documents
Culture Documents
Major Bridge-2x12.2 (1nos)
Major Bridge-2x12.2 (1nos)
Item Quantity
No. CODE Description Unit
1
Earthwork in excavation of foundation for structures complete as per drawing and
6A,01 Technical Specification Clause 304 including all Leads and Lifts 0
6A,01C a)Ordinary and soft Soils (material to be used in embankments) Cum 1127
6A,01C b)Ordinary and soft Soils (material to disposal) Cum 0
6A,01c c)Soft rock Cum 0
Providing Back filling behind abutments, wing walls and return walls, with
6A,02 6A,02 selected imported granular material of approved quality including all leads and Cum 125
lifts complete as per Technical Specification Clause 305.
Providing and laying of Filter media of Stone aggregate conforming to Technical
Specifications Clause 2504.2.2 behind abutment, wing wall, retaining wall and
6A,03 6A,03 return walls, complete as per drawing and Technical Specifications Clause 305 & Cum 49
2504.
Providing Plain Cement concrete for levelling course etc., under foundations
6A,04 including centering complete as per drawing and Technical Specification clauses 0
1500,1700,& 2100.
6A,04a PCC M15 grade Cum 29
6A,05 Providing and laying Reinforced cement concrete for foundations complete as per 0
drawing and Technical Specifications Section 1500,1700, 2100 & 2200
6A,06f HYSD bar reinforcement complete as per drawing and Technical Specification MT 4
clause no 1600. for 6A,06a to 6A,06e
Structural Cement concrete for Reinforced cement concrete for ABUTMENT CAP
6A,07 including centering complete as per drawing Technical specification clauses 0
1500,1700,2200
6A,07a PCC M30 Cum 0
6A,07b RCC M30 Cum 0
6A,07c RCC M35 Cum 20
6A,07d RCC M40 Cum 0
6A,07e RCC M45 Cum 0
6A,07f HYSD bar reinforcement complete as per drawing and Technical Specification MT 2
clause no 1600. for 6A,07g
Structural Cement concrete for Reinforced cement concrete for DIRT WALL
6A,08 including centering complete as per drawing Technical specification clauses 0
1500,1700,2200
6A,08f HYSD bar reinforcement complete as per drawing and Technical Specification MT 1
clause no 1600. for 6A,08a to 6A,08e
Structural Cement concrete for Reinforced cement concrete for PEDESTAL
6A,09 including centering complete as per drawing Technical specification clauses 0
1500,1700,2200
6A,09a PCC M30 Cum 0
6A,09b RCC M30 Cum 0
6A,09c RCC M35 Cum 0
6A,09d RCC M40 Cum 0
6A,09e RCC M45 Cum 0
6A,09f HYSD bar reinforcement complete as per drawing and Technical Specification MT 0
clause no 1600. for 6A,09a to 6A,08e
Structural Cement concrete for Reinforced cement concrete for PIER including
6A,10 centering complete as per drawing Technical specification clauses 0
1500,1700,2200
6A,10a PCC M30 Cum 0
6A,10b RCC M30 Cum 0
6A,10c RCC M35 Cum 183
6A,10d RCC M40 Cum 0
6A,10e RCC M45 Cum 0
HYSD bar reinforcement complete as per drawing and Technical Specification
6A,10f clause no 1600. for 6A,10a to 6A,10e MT 20
Structural Cement concrete for Reinforced cement concrete for PIER CAP
6A,11 including centering complete as per drawing Technical specification clauses 0
1500,1700,2200
6A,11a PCC M30 Cum 0
6A,11b RCC M30 Cum 0
6A,11c RCC M35 Cum 20
6A,11d RCC M40 Cum 0
6A,11e RCC M45 Cum 0
6A,11f HYSD bar reinforcement complete as per drawing and Technical Specification MT 2
clause no 1600. for 6A,11a to 6A,11e
Structural Cement concrete for Reinforced cement concrete/PSC for GIRDER
6A,12 including centering complete as per drawing Technical specification clauses 0
809,1500,1700
6A,12a RCC M30 Cum 0
6A,12b RCC M35 Cum 0
6A,12c RCC M40 Cum 0
6A,12d RCC M45 Cum 0
PSC GIRDER 0
6A,12e PSC M40 Cum 0
6A,12f PSC M45 Cum 0
6A,12g PSC M50 Cum 0
HYSD bar reinforcement complete as per drawing and Technical Specification
6A,12h clause no 1600. for 6A,12a to 6A12d MT 0
HT Steel for PSC concrete complete as per drawing and Technical Specification
6A,12i 1800,1009 for 6A,12e to 6A,12g MT 0
6A,13h HYSD bar reinforcement complete as per drawing and Technical Specification
clause no 1600. for 6A,13a to 6A,13d MT 60
6A,13i HT Steel for PSC concrete complete as per drawing and Technical Specification MT 0
1800,1009 for 6A,13e to 6A,13g
Providing bored cast-in-situ M35 grade RCC piles excluding reinforcement
6A,14 complete as per drawings and technical specifications and removal of excavated 0
earth with all lifts and lead up to 1000m
6A,14a RCC M35 Pile Cap Cum 0
6A,14b RCC M35 1.2m dia piles Rmt 0
6A,14c Providing MS Linear for Pile MT 0
6A,15 Pile load test on single vertical pile in accordance with IS:2911 (Part IV) 0
6A,15a a) Initial load test Nos 0
6A,15b b) Routine Load Test Nos 0
6A,18 Providing and fixing bearings complete as per drawing and Technical Specification 0
2000,2200 and 2300.
6A,18a a) Elastomeric bearings Sqm 0
6A,18b b) Pot bearings nos 0
6A,18c c) Craft Paper / Tap Paper bearings Sqm 0
Providing and fixing expansion joints complete as per drawing and Technical
6A,19 Specification No. 2600 and confirming to MoRT&H modified interim 0
specifications
6A,19a 20 mm thick compressible fibre board Rmt 11
Strip seal type of expansion joint complete as per drawing and Technical
6A,19b specification Cum 16
6A,21 6A,21 Providing weep holes in abutments, wing walls and return walls complete as per Nos 58
drawing and Technical Specification 2706.
6A,23 6A,23 Providing and Construction of Hand-Railing (cast-in-situ) M35 Grade including Rmt 0
cost of centering as per approved Drawings and Technical Specifications
Painting of Crash Barrier and Hand Railing By applying 2 coats of water based
6A,24 6A,24 cement paint to unplastered concrete surface after cleaning the surface of dirt, Sqm 0
dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 Sq.m. )
6A,26 6A,26 Painting of FO / ROB / RUB No. and Span arrangement as per Technical Nos 2
specifications
Providing Plain Cement Concrete for Curtainwalls /toe walls etc. including
6A,27 centering all complete as per drawing and Technical Specifications Section Section 0
1500 & 1700
6A,27C PCC M15 Cum 0
6A,27C PCC M20 Cum 0
6A,28 6A,28 Providing and laying Dry Boulder apron complete as per Drawings and Technical Cum 0
Specifications Clause 2503
Providing and laying PCC filling for bed protection as per Drawings and Technical
6A,29 Specifications 0
6A,30 6A,30 Providing boulder apron complete as per drawings and Technical Specifications Cum 0
Section 2500
Filter media (150 mm thick) underneath pitching in slopes and flat surfaces
6A,31 6A,31 Cum 7
complete as per drawing & Technical Specification Clause 2504
6A,32 6A,32 Stone pitching on sloped sufaces (300 mm thick) for earth protection complete Cum 14
(for Quadrants) as per drawings and Technical Specification 2504
Construction of flexible apron 1 m thick comprising of loose stone boulders
6A,33 6A,33 weighing not less than 40 kg beyond curtain wall. Cum 0
6A,34 6A,34 Providing and laying flat stone apron 150 mm thick flat stone embedded in 300 Cum 0
mm thick concrete Grade M15
6A,35 6A,35 Provision for Protection Works L.Sum 0
Carry out confirmatory bores upto required depths at each foundation location of
bridge complete in all respects including testing as per Technical Specifications
6A,36 Section 2400 and interpretation of the bore data and presentation of the results 0
as per IRC
6A,36a i) Depth between 0 m to 10 m Rmt 0
6A,36A ii) Depth between 10 m to 20 m Rmt 0
6A,36A iii) Depth between 20 m to 30 m Rmt 0
6A,37 Providing and Construction of RCC Retaining Wall / Median Wall complete as per 0
drawing and Technical Specification clauses 1500,1700,2200
6A,37a M25 Grade 0
6A,37b M30 Grade 0
6A,37c M35 Grade Cum 0
6A,38 Providing and Fixing Steel Girder for Superstructure as per Technical Specification MT 27
1127.50 1127.50
2 Concrete grade M 15 for levelling course cum
For abutments 2 8.75 3.73 0.15 9.78
Pier 1 11.40 5.00 0.15 8.55
Retaining Wall 0 3.52 5.65 0.15 0.00
Median wall 0 2.00 5.65 0.15 0.00
PCC for Pile
Abutment 0 38.56 5.40 0.15 0.00
Pier 0 12.60 5.30 0.15 0.00
28.70 28.70
3 Filter media cum
For abutments 2 7.85 0.60 5.25 49.44
RCC Return wall with Abutment wall 0 0.75 0.60 5.25 0.00
Retaining Wall 0 3.37 0.60 5.37 0.00
Median wall 0 2.00 0.60 6.00 0.00
49.44 49.44
4 Back fill cum
For abutments 2 7.85 3.03 2.62 124.82
Retaining Wall 0 3.37 3.10 2.68 0.00
Median wall 0 2.00 3.46 3.00 0.00
RCC Return wall 0 0.00 3.03 2.62 0.00
124.82 124.82
5 Concrete in Median/Retaining Wall M35 cum
Retaining Wall 0 3.37 3.21 0.00
0 3.37 0.53 6.00 0.00
Median wall 0 2.00 3.21 0.00
0 2.00 0.53 6.00 0.00
0.00 0.00
6 Concrete in foundation M 35 cum
For abutments 2 7.85 2.53 39.73
For Pier 1 47.355 47.36
87.09 87.09
0.00 0.00
12 Solid Slab M35 cum 1 26.60 5.42 1.48 212.65
Wedge 2 0.61 5.42 0.00 0.00 212.65
13 Concrete in Superstructure M 35 cum
Longitudinal Girder (RCC)
End Portion 0 1.38 0.05 0.00
Variable Portion 0 1.50 0.14 0.00
Mid Portion 0 13.88 0.22 0.00
0.00 0.00
End Cross Girder 0 2.40 0.40 -0.40 0.00
15 Appraoch slab
PCC grade M 15 levelling course cum 0 7.85 3.30 0.15 0.00 0.00
M30 grade concrete cum 0 7.85 3.50 0.30 0.00 0.00
30 Elastomeric Bearings CC
Abutment & Pier 0 50 32 6.5 0
0 0.00
31 Expansion joint Filler Type
Filler Type Lin.m. 2 5.42 10.84 10.84
0.00 0.00
47 Initial Test of Pile Nos 0 0 0.00
48 Routine Test on Pile Nos 0 0 0.00
27.27 27.27
50 Curtain wall
Excavation Cum 1 12.8 0.9 2 23.04
Rcc M20 Cum 1 12.2 0.9 0.54 5.9292
1 12.2 0.25 1.46 4.453
TOTAL = 10.3822
51 Toe wall cum
Excavation 4 9.7089 2.112 1.4 114.829102
Pcc 4 9.3089 1.712 0.1 6.37473472
Rcc M20 0
a 4 9.1089 1.512 0.15 8.26359408
b 4 9.1089 1.512 0.15 8.26359408
c 4 9.1089 1.512 1 55.0906272
71.6178154
52 Return wall 0
Excavation 4 4.1 4 8.1 531.36 646.1891021
Pcc 4 3.7 2.7 0.1 3.996 10.37073472
Rcc 0
a 4 3.5 0.5 0.5 3.5
b 4 3.5 0.5 5.5 38.5
113.6178154
Author:
Enter No of Bearing here
Bearing Elastomeric in One Support
General data Enter Value 1 as per Type of Bearing
End Diaphragm
Area 0.00
Well Foundation Thickness 0.70
No of Abutment 0
No of Pier 0 Girder (BOX Type) Mid Section
Abutment Well Dia 8 Depth of Girder -0.60
Pier Well Dia 6 0.00 Bottom width 4.70 1.9
Height of Curb in Abutment 2.5 bottom thickness 0.35
Height of Curb in Pier 1.9 bottom area 1.16 (i)
Well Wall Thickness Abutment 1.25 Side wall thickness 0.350
Well Wall Thickness Pier 1.00 Side wall length 1.170
Inner Dia of Well Abutment 5.50 Side walls area ( Two Nos ) 0.819 (ii)
Inner Dia of Well Pier 4.00 Hauches area 0.35 (iii)
Well Total Depth Abutment 20.00 Slab Thickness Mid 0.250
Well Total Depth Pier 30.00 Slab length Mid 6.700
Well Cap Thickness Abutment 1.80 Mid Slab area 1.675 (iv)
Well Cap Thickness Pier 1.80 Intermediate Beam Area (v)
Nos of Intermediate including Top Plug for Abutment 1 Foot Path Portion area ( Slab) ( 2 Nos) 0.990 (vi)
Nos of Intermediate including Top Plug for Pier 1 Total Cross sectional Area of Box Girde 4.989 total
Abutment Well Cap Length 11.7
Abutment Well Cap Width 8
4.12
26
27
26
26
5.20600000000002
0.576 1.476
5 6 7 8
C F E G
1.00 0.15 0.15 0.30
1.00 0.20 0.25 0.30
1.20 0.30 0.30 0.30
1.40 0.35 0.40 0.30
1.40 0.45 0.45 0.30
1.60 0.60 0.40 0.30
2.50 0.60 0.50 0.30
2.75 1.23 0.50 0.35
3.15 1.40 0.50 0.50
3.55 1.59 0.50 0.50
3.95 1.74 0.50 0.50