1. Which of the following techniques are effective when trying to recover refrigerant into a
non-pressurized container from a refrigerator with an inoperative compressor?
2. After installing and opening a piercing access valve, it must be ensured that the system
pressure is greater than _______ before beginning the recovery procedure.
3. When using a system dependent recovery device with an operating compressor, _____
4. When using water to sustain tank pressure during system charging, the water
temperature should not exceed
a. SPDT relay
b. relay with two separate switches
c. DPST relay
d. DPDT relay
7. In the illustration for question 6, the contacts marked NO will be:
a. step up transformer
b. step down transformer
c. ac to dc rectification
d. rewire circuit with a smaller gauge wire
a. split system
b. a terminal system with a remote condenser
c. a packaged unit
d. none of the above
11. The standard type of copper tubing used more frequently in the heating and air-
conditioning industry is
a. K b. L c. DWV d. M
12. The size of 1/2 inch would refer to the _______ with regard to ACR copper tubing.
14. By standard design practice, a cooling tower operates with the following gpm flow rate
and temperature difference:
a. 2 gpm with 15 degrees temperature difference
b. 1.5 gpm with a 20 degree delta T
c. 3 gpm with a 10 degree delta T
d. 3 gpm with a 20 degree delta T
15. Flooded systems differ from direct expansion systems in that flooded systems …
a. require a greater refrigerant charge
b. typically use low side and/or high side floats as metering devices
c. typically use TXVs as metering devices
d. both a. and b. are correct
17. When recovering refrigerant from small appliances with inoperative compressors, the
recovering unit must be connected to:
a. Only the high side of the system
b. Only the low side of the system
c. both the high and low side of the system
d. none of the above
18. Technicians that handle refrigerant during service, maintenance, or repair of small
appliances must have:
a. Type I
b. Type I or Universal certification
c. Universal certification.
d. no certification
19. Units manufactured before 1950 should not be recovered using current equipment because
a. Recovering old equipment is out of fashion
b. The units contain ammonia, hydrogen or water
c. Units might contain methyl formate, methyl chloride and sulphur dioxide
d. It’s too old to salvage
20. System dependent devices can be used to recover refrigerants from devices with less than
___ pounds of refrigerant.
a. 5 b. 10 c. 15 d. 20
35. Which compressor type uses tapered, machined gear components to trap the gas
for compression?
a. Scroll b. reciprocating c. rotary d. screw
39. The advantage of forced draft over a natural draft cooling tower is:
a. The possibility of lower water outlet temperature
b. There is no dependence on natural wind velocity
c. Use of a smaller sized tower
d. All of the above
40. The condenser that uses air and water for cooling is the:
a. Air cooled condenser
b. Water cooled condenser
c. Evaporative condenser
d. Both a. and b. are correct
44. One of the most common fan motors used for operating condensers and
evaporators is the:
A. Repulsion start induction motor
B. Capacitor start induction motor
C. Squirrel cage induction motor
D. Synchronous motor
45. In order for a motor to operate satisfactorily and deliver full horsepower, the motor
should operate most nearly …
a. at its rated frequency and no more than 10% above or below its rated voltage
b. no more than 10% variation above its rated voltage, and no more greater than
20% variation below its rated frequency.
c. at its rated voltage and at least 20% slip
d. at its rated voltage and 20%q frequency variation.
Questions 46 through 49 are fill-in the blank questions and reference to low voltage thermostat
wiring color coding:
46. The power lead from the transformer to the thermostat is color coded _____.
47. The thermostat lead for cooling is color coded _____.
48. The thermostat lead for heating is color coded _____.
49. The low voltage transformer neutral lead is color coded _____.
50. Failure of a system to hold a vacuum at the end of the evacuation process indicates
that _______
a. A leak in the system exists
b. The system is ready to be charged
c. The compressor is over-pressurizing the system
d. The metering device (expansion valve) is not operating
56. System-dependent recovery process must use a pressurized container to capture the
refrigerant
a. False b. True
57. The color of the pressure port of the manifold pressure gauge that is connected to the low
pressure side of the system:
a. Yellow b. Blue c. Red d. Green
58. Which of the following is used to minimize the leakage of refrigerant while checking the
pressure of the system:
a. Self-sealing hoses
b. Hand valves
c. Either can be used
d. neither a. nor b.
59. ____ uses its own power to recover the refrigerant from systems:
a. Active recovery equipment
b. Passive recovery equipment
c. Both Active and Passive recovery equipment
d. none of the above
61. Long hoses between the unit and the recovery machine results in _______ in recovery time:
a. Decrease
b. no impact
c. Increase
d. depends on type of hose
62. Which type of leak detector works by drawing the vapor into the system and heating it:
a. Helium leak detector
b. Electronic leak detector
c. Fluorescent leak detector
d. Ultrasonic leak tester
63. Which of the following is not the most effective way to detect the general area of a small
leaks:
a. Electronic tester
b. fluorescent Indicator
c. Ultrasonic tester
d. All the options are correct
67. If the label identifying the refrigerant is missing, then which of the following method is used
to identify the type of refrigerant:
a. Density - Volume method
b. Density–Temperature method
c. Pressure–Temperature method
d. All the options are correct
68. The pressure of Nitrogen at which that is introduced into the evacuation system after
evacuation of refrigerant is:
a. Equal the atmospheric pressure
b. Any atmospheric pressure
c. Slightly above the atmospheric pressure
d. Slightly lower than the atmospheric pressure