You are on page 1of 4

(A). Choose the correct answer.

(10 marks)
i. A low evaporator superheat indicates
A. undercharge. B. system restriction. C. overcharge. D. dirt
buildup.
ii. Which compressor type uses pistons to compress the gas?
A. Scroll B. Reciprocating C. Rotary D. Screw
iii. Which is not a basic component of the compression refrigeration cycle?
A. Compressor B. Condenser C. Evaporator D. Suction
filter
iv. Large or small compressors on parallel compressor racks, which are usually dedicated to the
coldest cases, are called
A. satellite compressors. B. remote compressors.
C. booster compressors. D. both A and C.
v. . What type of defrost is normally used for vending machine medium-temperature
applications?
A. Electric B. Hot gas C. Off cycle D. None of the above
vi. Which are power supplies used for truck refrigeration?
A. Gas-engine driven compression B. Diesel compressor
C. Electric compressor operated with a motor generator D. All of the above
vii. An automatic expansion valve system responds to an overcharge of refrigerant by
A. low suction pressure. B. high head pressure.
C. a flooded compressor. D. both B and C
viii. The capillary tube is a type of
A. external equalizer B. metering device

C. TXV sensor D. device that senses the superheat


ix. The advantage of one large compressor for several refrigerated cases is
A. larger motors are more efficient B. larger motors last longer

C. larger motors are quieter D. larger motors are less expensive to buy
x. In a high temperature refrigeration unit, the evaporator coil is normally ______ lower than the
refrigerated box temperature.

A. 10F to 20F B. 25F to 35F C. 35F to 45F D. 5F to 15F

1(B). Fill in the blanks. (10 marks)


i. A refrigerant system’s evaporator typically runs about ________ degrees of superheat.
ii. When a standard-efficiency air-cooled condenser is used, the condensing refrigerant will
normally be _______ °F higher in temperature than the entering air temperature.
iii. The tube-width-a-tube condenser is ________ condenser.
iv. The needle and seat of a TXV are normally made of ________.
v. Two types of relief valves are ______ and ______.
vi. The two broad categories of display cases are _______ and _______.
vii. List the evaporating temperatures for liquid nitrogen and CO2: ________ and ________.

Choose the correct answer.


(i)C. overcharge.
(ii)B. Reciprocating
(iii)D. Suction filter
(iv)D. both A and C.
(v)C. Off cycle
(vi)D. All of the above
(vii)B. high head pressure
(viii)B. metering device
(ix)A. larger motors are more efficient
(x)A. 10F to 20F

Fill in the blanks.


(i)8F to 12F
(ii030°F
(iii)a water cooled
(iv)Stainless steel
(v)Spring loaded (closes back after functioning) and one time type (does not close back after
functioning)
(vi)Open and close
(vii)320F,  109 F

1(A). Choose the correct answer. (10 marks)


i. Refrigerant in the evaporator
A. changes from vapor to liquid. B. changes from liquid to vapor.
C. stays in the vapor state. D. stays in the liquid state.
ii. The coil in a shell-and-coil condenser must be cleaned
A. by removing the end caps B. with a brush
C. chemically D. by air pressure
iii. Which compressor type uses tapered, machined gear components to trap the gas for
compression?
A. Scroll B. Reciprocating C. Rotary D.
Screw
iv. What special precautions should be taken with drain lines in walk-in coolers?
A. Freeze protection B. Trapping to prevent air from being pulled
in
C. Downward sloping D. All of the above
v. What special valve is used in a refrigerated air drier?
A. Four-way valve B. Defrost valve
C. Three-way valve D. Hot gas bypass valve
vi. At what evaporator temperature does an ice maker usually begin to make ice?
A. 35°F B. 32°F C. 25°F D. 20°F
vii. A capillary tube system responds to an overcharge of refrigerant by
A. high suction pressure. B. high head pressure.
C. a flooded compressor. D. all of the above
viii. The difference between the superheat set point of an electronic expansion valve and the
actual superheat is called a(n)

A. error B. algorithm C. range D. differential


ix. The oil separator is normally located between the
A. condenser and the receiver B. evaporator and the compressor
C. receiver and the expansion valve D. compressor and the condenser
x. Medium temperature refrigerated box temperature range from about
A. 20F to 32F B. 30F to 45F C. 40F to 50F D. 50F to
60F

1(B). Fill in the blanks. (10 marks)


i. The TXV tries to maintain a constant ________ in the evaporator.
ii. Two methods for accomplishing defrost on low temperature refrigeration systems are _____
and _____.
iii. The three temperature ranges for refrigeration systems are __________, __________, and
__________.
iv. Two methods used to power refrigeration compressors on a ship are ______ and ______.
v. When food dehydration is not a factor, the coil-to-air temperature relationship is ______ to
______°F.
1(A). Choose the correct answer.
i. B. changes from liquid to vapor
ii. C. chemically
iii. D. Screw
iv. D. All of the above
v. D. Hot gas bypass valve
vi. D. 20°F
vii. D. all of the above
viii. A. error
ix. D. compressor and the condenser
x. B. 30F to 45F

1(B). Fill in the blanks.


i. Superheat
ii. Hot gas and electric
iii. High, medium and low
iv. electricity, steam turbine
v. 16 to 22°F

You might also like