You are on page 1of 14

19" 4U / 100Ah Lithium Battery

SLB48-100-144-1
13S Series, Generation 5

Incell Smart Lithium Battery™ is an advanced power backup


system for telecom use. Its rechargeable lithium-ion battery
provides reliable power backup for hybrid, off-grid and grid-
connected telecom sites worldwide.
Technical Specification
Enclosure Size 19" 4U Safe
Lithium Chemistry NMC All our products are designed with
your safety in mind - thoroughly
Rated Voltage 48 V verified and certified for safe
Capacity Ah 100 Ah
operation.
Energy Wh 4746 Wh Simple
Advanced technology made
Calendar Life @ 80% SOC 20 years
super easy to use. easy to install,
Peak Discharge Power 6kW for 60 seconds maintenance free, charge control.
Discharge Cutoff Current 100 A
Strong
End-of-Discharge Voltage (LVBD)** 39 V Works in all conditions and
Charge Cutoff Current 50 A
environments. Extra protection
against dust and moisture for
Charge Current Limitation (CLD)* 50 A prolonged life.
Charge Voltage for 100% SOC 54.6 V
Smart
Charge Voltage for 80% SOC 52 V Automatic balancing, automatic
Operating Temperature Charging 0 to +55°C reconnect, remote monitoring
options and much more.
Operating Temperature Discharging -20 to +60°C
Storage Temperature -20 to +60°C Secure
Our unique, patented Anti-Theft
Weight (Kg) Approx. 35 Kg Device disables function of batteries
Dimensions (mm) W 440 D 352 H 173 if removed from site. It’s prepared for
optional GPS tracker.
Circuit breaker 100 A, BMS Controlled, single pole
IP class IP20 Sustainable
The lifetime is extraordinary long. It’s
Communication Protocols RS485, RJ45 (2) ports, Modbus small, light, maintenance free and can
Safety Standards IEC62619, IEC62368, UN38.3 be remotely controlled.
Software for PC (Incell Studio)
included for full local monitoring and
Management & Monitoring
management. Remote
connection via Modbus

*If the recharge current is 50A or higher, the battery will automatically reduce the charge current to 6-12A temporarily
** Cut off when one cell reaches 3.0V, 13 cells in series Datasheet SLB48-100-144-1 Version 2

Incell International AB ; Jan Stenbecks Torg 17, PO Box 1037, SE-164 21, Kista, Sweden ; info@incellint.com
Phone: +46 8 5454 4000 ; www.incellint.com
19" 4U / 100Ah Lithium Battery
SLB48-100-144-1
13S Series, Generation 5

SOC vs Voltage @ RT Constant Current Discharge Performance @ RT


Voltage V Capacity @0.2C Capacity 0.5C Capacity 1C
SOC EODV
(20A) (50A) (95A)
(%) 0.2C 0.5C 1C
Discharge Discharge Discharge 47.0 V 53.8 Ah 49.7 Ah 42.9 Ah
100 54.0 54.0 54.0 46.0 V 73.2 Ah 66.7 Ah 55.9 Ah
90 52.1 52.0 51.4 45.0 V 85.7 Ah 82.5 Ah 73.4 Ah
80 50.7 50.6 49.9 44.0 V 93.8 Ah 91.4 Ah 86.6 Ah
70 49.4 49.3 48.6 43.0 V 98.7 Ah 98.5 Ah 95.3 Ah
60 48.1 48.0 47.4 42.0 V 100 Ah 100 Ah 99.6 Ah
50 47.2 47.1 46.4 41.0 V 101 Ah 101 Ah 101 Ah
40 46.6 46.4 45.8 40.0 V 101.7 Ah 101.7 Ah 101.7 Ah
30 46.1 45.9 45.2
20 45.4 45.3 44.6 Standard accessories included with this battery are: (1)
10 44.2 44.2 43.7
communication cable, (1) pair of mounting brackets, (1) printed
specification installation guide, and (1) CAN Bus/MOD Bus
0 39.8 39.7 39.4
Terminator

Constant Power Discharge Performance @ RT


Batt V 2500 W 2300 W 2000 W 1800 W 1500 W 1200 W 1000W 750 W 500 W
47,00 27 min 31 min 37 min 46 min 55 min 1 h 14 min 1 h 43 min 2 h 43 min 5 h 30 min
46,50 30 min 35 min 41 min 50 min 1 h 3 min 1 h 24 min 1 h 58 min 3 h 8 min 6 h 16 min
46,00 33 min 39 min 47 min 57 min 1 h 11 min 1 h 36 min 2 h 14 min 3 h 33 min 7 h 10min
45,50 37 min 43 min 53 min 1 h 4 min 1 h 20 min 1 h 47 min 2 h 29 min 3 h 53 min 7 h 55 min
45,00 41 min 48 min 58 min 1 h 10 min 1 h 28 min 1 h 56 min 2 h 40 min 4 h 7 min 8 h 15 min
44,50 NA 53 min 1 h 4 min 1 h 16 min 1 h 34 min 2 h 3 min 2 h 48 min 4 h 17 min 8 h 36 min
44,00 NA 57 min 1 h 8 min 1 h 21 min 1 h 39 min 2 h 8 min 2 h 54 min 4 h 27 min 9 h 00 min
43,50 NA 1 h 1 min 1 h 11 min 1 h 25 min 1 h 43 min 2 h 13 min 3 h 00 min 4 h 35 min 9 h 10 min
43,00 NA 1 h 3 min 1 h 14 min 1 h 27 min 1 h 45 min 2 h 16 min 3 h 3 min 4 h 40 min 9 h 20 min
42,50 NA 1 h 5 min 1 h 15 min 1 h 29 min 1 h 47 min 2 h 18 min 3 h 6 min 4 h 43 min 9 h 27 min
42,00 NA 1 h 6 min 1 h 16 min 1 h 30 min 1 h 48 min 2 h 19 min 3 h 7 min 4 h 44 min 9 h 30 min
41,50 NA 1 h 6 min 1 h 17 min 1 h 30 min 1 h 49 min 2 h 20 min 3 h 8 min 4 h 45 min 9 h 32 min
41,00 NA 1 h 7 min 1 h 17 min 1 h 30 min 1 h 49 min 2 h 20 min 3 h 9 min 4 h 46 min 9 h 34 min
40,50 NA 1 h 7 min 1 h 18 min 1 h 31 min 1 h 50 min 2 h 21 min 3 h 9 min 4 h 47 min 9 h 36 min
40,00 NA 1 h 7 min 1 h 18 min 1 h 31 min 1 h 50 min 2 h 21 min 3 h 9 min 4 h 48 min 9 h 37 min
39,50 NA 1 h 8 min 1 h 19 min 1 h 32 min 1 h 50 min 2 h 21 min 3 h 10 min 4 h 48 min 9 h 38 min
39,00 NA NA 1 h 19 min 1 h 32 min 1 h 50 min 2 h 22 min 3 h 10 min 4 h 49 min 9 h 39 min

Technical Drawings Mounting Bracket

Optional Mounting Directions


of Brackets Shown

Datasheet SLB48-100-144-1 Version 2

Incell International AB ; Jan Stenbecks Torg 17, PO Box 1037, SE-164 21, Kista, Sweden ; info@incellint.com
Phone: +46 8 5454 4000 ; www.incellint.com
19" 4U / 100Ah Lithium Battery
SLB48-100-144-2
14S Series, Generation 5

Incell Smart Lithium Battery™ is an advanced power backup


system for telecom use. Its rechargeable lithium-ion battery
provides reliable power backup for hybrid, off-grid and grid-
connected telecom sites worldwide.
Technical Specification
Enclosure Size 19" 4U Safe
Lithium Chemistry NMC All our products are designed with
your safety in mind - thoroughly
Rated Voltage 48 V verified and certified for safe
Capacity Ah 100 Ah
operation.
Energy Wh 5111 Wh Simple
Advanced technology made
Calendar Life @ 80% SOC 20 years
super easy to use. easy to install,
Peak Discharge Power 6kW for 60 seconds maintenance free, charge control.
Discharge Cutoff Current 100 A
Strong
End-of-Discharge Voltage (LVBD)** 42 V Works in all conditions and
Charge Cutoff Current 50 A
environments. Extra protection
against dust and moisture for
Charge Current Limitation (CLD)* 50 A prolonged life.
Charge Voltage for 100% SOC 58.8 V
Smart
Charge Voltage for 80% SOC 56 V Automatic balancing, automatic
Operating Temperature Charging 0 to +55°C reconnect, remote monitoring
options and much more.
Operating Temperature Discharging -20 to +60°C
Storage Temperature -20 to +60°C Secure
Our unique, patented Anti-Theft
Weight (Kg) Approx. 36 Kg Device disables function of batteries
Dimensions (mm) W 440 D 352 H 173 if removed from site. It’s prepared for
optional GPS tracker.
Circuit breaker 100 A, BMS Controlled, single pole
IP class IP20 Sustainable
The lifetime is extraordinary long. It’s
Communication Protocols RS485, RJ45 (2) ports, Modbus small, light, maintenance free and can
Safety Standards IEC62619, IEC62368, UN38.3 be remotely controlled.
Software for PC (Incell Studio)
included for full local monitoring and
Management & Monitoring
management. Remote
connection via Modbus

*If the recharge current is 50A or higher, the battery will automatically reduce the charge current to 6-12A temporarily
** Cut off when one cell reaches 3.0V, 14 cells in series Datasheet SLB48-100-144-2 Version 2

Incell International AB ; Jan Stenbecks Torg 17, PO Box 1037, SE-164 21, Kista, Sweden ; info@incellint.com
Phone: +46 8 5454 4000 ; www.incellint.com
19" 4U / 100Ah Lithium Battery
SLB48-100-144-2
14S Series, Generation 5

SOC vs Voltage @ RT Constant Current Discharge Performance @ RT


Voltage V Capacity @0.2C Capacity 0.5C Capacity 1C
SOC EODV
(20A) (50A) (95A)
(%) 0.2C 0.5C 1C
Discharge Discharge Discharge 50.0 V 63.0 Ah 59.7 Ah 49.7 Ah
100 58.1 58.1 58.1 49.0 V 78.0 Ah 77.5 Ah 64.0 Ah
90 56.1 56.0 55.4 48.0 V 87.7 Ah 87.5 Ah 79.5 Ah
80 54.6 54.5 53.7 46.0 V 93.8 Ah 93.4 Ah 91.6 Ah
70 53.2 53.1 52.3 45.0 V 96.7 Ah 96.5 Ah 95.3 Ah
60 51.8 51.7 51.0 44.0 V 98.2 Ah 98.0 Ah 97.2 Ah
50 50.8 50.7 50.0 42.0 V 102.0Ah 102.0 Ah 101.9 Ah
40 50.2 50.0 49.3
30 49.6 49.4 48.7 Standard accessories included with this battery are: (1)
20 48.9 48.8 48.0 communication cable, (1) pair of mounting brackets, (1) printed
specification installation guide, and (1) CAN Bus/MOD Bus
10 47.6 47.6 47.1
Terminator
0 42.9 42.8 42.4

Constant Power Discharge Performance @ RT


Batt V 4800 W 4300 W 3700 W 3200 W 2500 W 1600 W 1200 W 1000 W 500 W
49,00 35 min 43 min 53 min 1h 1 h 25 min 2 h 29 min 3 h 10 min 3 h 40 min 7 h 40 min
48,50 37 min 48 min 58 min 1 h 5 min 1 h 32 min 2 h 39 min 3 h 20 min 4h 8 h 10 min
48,00 40 min 52 min 1 h 3 min 1 h 9 min 1 h 37 min 2 h 47 min 3 h 30 min 4 h 8 min 8 h 40 min
47,50 NA 56 min 1 h 7 min 1 h 13 min 1 h 42 min 2 h 53 min 3 h 38 min 4 h 17 min 8 h 50 min
47,00 NA 1h 1 h 11 min 1 h 16 min 1 h 46 min 2 h 58 min 3 h 44 min 4 h 20 min 8 h 58 min
46,50 NA 1 h 2 min 1 h 13 min 1 h 20 min 1 h 49 min 3 h 2 min 3 h 48 min 4 h 26 min 9 h 4 min
46,00 NA 1 h 4 min 1 h 15 min 1 h 22 min 1 h 52 min 3 h 5 min 3 h 52 min 4 h 28 min 9 h 10 min
45,50 NA 1 h 5 min 1 h 16 min 1 h 24 min 1 h 54 min 3 h 6 min 3 h 56 min 4 h 30 min 9 h 15 min
45,00 NA 1 h 6 min 1 h 17 min 1 h 25 min 1 h 55 min 3 h 7 min 3 h 59 min 4 h 32 min 9 h 20 min
44,50 NA 1 h 7 min 1 h 17 min 1 h 25 min 1 h 56 min 3 h 8 min 4h 4 h 34 min 9 h 26 min
44,00 NA 1 h 7 min 1 h 18 min 1 h 26 min 1 h 57 min 3 h 9 min 4 h 1 min 4 h 35 min 9 h 28 min
43,50 NA 1 h 7 min 1 h 18 min 1 h 26 min 1 h 58 min 3 h 9 min 4 h 2 min 4 h 36 min 9 h 30 min
43,00 NA 1 h 7 min 1 h 18 min 1 h 26 min 1 h 58 min 3 h 10 min 4 h 3 min 4h 38min 9 h 32 min
42,50 NA NA 1 h 18 min 1 h 27 min 1 h 58 min 3 h 10 min 4 h 4 min 4 h 39 min 9 h 34 min
42,00 NA NA 1 h 18 min 1 h 27 min 1 h 59 min 3 h 10 min 4 h 5 min 4 h 40 min 9 h 40 min

Technical Drawings Mounting Bracket

Optional Mounting Directions


of Brackets Shown

Datasheet SLB48-100-144-2 Version 2

Incell International AB ; Jan Stenbecks Torg 17, PO Box 1037, SE-164 21, Kista, Sweden ; info@incellint.com
Phone: +46 8 5454 4000 ; www.incellint.com
19" 4U / 100Ah Lithium Battery
SLB48-100-145-5
15S Series, Generation 5

Incell Smart Lithium Battery™ is an advanced power backup


system for telecom use. Its rechargeable lithium-ion battery
provides reliable power backup for hybrid, off-grid and grid-
connected telecom sites worldwide.
Technical Specification
Enclosure Size 19" 4U Safe
Lithium Chemistry LFP All our products are designed with
your safety in mind - thoroughly
Rated Voltage 48 V verified and certified for safe
Capacity Ah 100 Ah
operation.
Energy Wh 4800 Wh Simple
Advanced technology made
Calendar Life @ 80% SOC 15 years
super easy to use. easy to install,
Peak Discharge Power 6kW for 60 seconds maintenance free, charge control.
Discharge Cutoff Current 100 A
Strong
End-of-Discharge Voltage (LVBD) 39 V Works in all conditions and
Charge Cutoff Current 50 A
environments. Extra protection
against dust and moisture for
Charge Current Limitation (CLD)* 50 A prolonged life.
Charge Voltage for 100% SOC 54.75 V
Smart
Charge Voltage for 80% SOC 52 V Automatic balancing, automatic
Operating Temperature Charging 0 to +55°C reconnect, remote monitoring
options and much more.
Operating Temperature Discharging -20 to +60°C
Storage Temperature -20 to +60°C Secure
Our unique, patented Anti-Theft
Weight (Kg) Approx. 44 Kg Device disables function of batteries
Dimensions (mm) W 440 D 420 H 173 if removed from site. It’s prepared for
optional GPS tracker.
Circuit breaker 100 A, BMS Controlled, single pole
IP class IP20 Sustainable
The lifetime is extraordinary long. It’s
Communication Protocols RS485, RJ45 (2) ports, Modbus small, light, maintenance free and can
Safety Standards IEC62619, IEC62368, UN38.3 be remotely controlled.
Software for PC (Incell Studio)
included for full local monitoring and
Management & Monitoring
management. Remote
connection via Modbus

*If the recharge current is 50A or higher, the battery will automatically reduce the charge current to 6-12A temporarily
Datasheet SLB48-100-145-5 Version 2

Incell International AB ; Jan Stenbecks Torg 17, PO Box 1037, SE-164 21, Kista, Sweden ; info@incellint.com
Phone: +46 8 5454 4000 ; www.incellint.com
19" 4U / 100Ah Lithium Battery
SLB48-100-145-5
15S Series, Generation 5

SOC vs Voltage @ RT

Batt V 4000 W 3000 W 2400 W 1500 W 1200 W 600 W

48,00 41% 35% 31% 23% 22% 20%


47,00 16% 14% 13% 8% 8% 8%
46,00 6% 6% 6% 4% 4% 4%
45,00 4% 4% 4% 3% 3% 3%
44,00 3% 3% 3% 2% 2% 2%
43,00 2% 2% 2% 1% 1% 1%
42,00 2% 2% 1% 1% 1% 1%
41,00 1% 1% 1% 1% 1% 1%
40,00 0% 0% 0% 0% 0% 0%
39,00 0% 0% 0% 0% 0% 0%

Constant Power Discharge Performance @ RT Technical Drawings


Batt V 4000 W 3000 W 2400 W 1500 W 1200 W 600 W

48,00 41 min 1 h 2 min 1 h 20 min 2 h 25 min 2 h 54 min 6 h 20 min

47,50 51 min 1 h 15 min 1 h 32 min 2 h 39 min 3 h 13 min 6 h 45 min

47,00 59 min 1 h 22 min 1 h 41 min 2 h 54 min 3 h 31 min 7 h 20 min

46,50 1 h 3 min 1 h 26 min 1 h 47 min 2 h 59 min 3 h 39 min 7 h 25 min

46,00 1 h 6 min 1 h 29 min 1 h 49 min 3 h 1 min 3 h 41 min 7 h 30 min

45,50 1 h 7 min 1 h 30 min 1 h 50 min 3 h 2 min 3 h 43 min 7 h 30 min O


45,00 1 h 7 min 1 h 31 min 1 h 51 min 3 h 3 min 3 h 44 min 7 h 35 min

44,50 1 h 8 min 1 h 31 min 1 h 52 min 3 h 4 min 3 h 45 min 7 h 35 min

44,00 1 h 8 min 1 h 32 min 1 h 53 min 3 h 5 min 3 h 46 min 7 h 40 min

43,50 1 h 8 min 1 h 32 min 1 h 53 min 3 h 6 min 3 h 47 min 7 h 43 min

43,00 1 h 9 min 1 h 33 min 1 h 53 min 3 h 7 min 3 h 48 min 7 h 46 min

42,50 1 h 9 min 1 h 33 min 1 h 54 min 3 h 7 min 3 h 49 min 7 h 48 min

42,00 1 h 9 min 1 h 33 min 1 h 54 min 3 h 8 min 3 h 49 min 7 h 50 min


Optional Mounting Directions
41,50 1 h 9 min 1 h 34 min 1 h 55 min 3 h 8 min 3 h 50 min 7 h 52 min of Brackets Shown
41,00 1 h 10 min 1 h 34 min 1 h 55 min 3 h 8 min 3 h 50 min 7 h 53 min
Mounting Bracket
40,50 1 h 10 min 1 h 34 min 1 h 55 min 3 h 9 min 3 h 50 min 7 h 54 min

40,00 1 h 10 min 1 h 34 min 1 h 55 min 3 h 9 min 3 h 51 min 7 h 55 min

39,50 1 h 10 min 1 h 35 min 1 h 56 min 3 h 9 min 3 h 51 min 7 h 56 min

39,00 1 h 10 min 1 h 35 min 1 h 56 min 3 h 9 min 3 h 51 min 7 h 57 min

Standard accessories included with this battery are: (1) communication cable, (1) pair of mounting brackets, (1) printed specification
installation guide, and (1) CAN Bus/MOD Bus Terminator
Datasheet SLB48-100-145-5 Version 2

Incell International AB ; Jan Stenbecks Torg 17, PO Box 1037, SE-164 21, Kista, Sweden ; info@incellint.com
Phone: +46 8 5454 4000 ; www.incellint.com
19" 4U / 150Ah Lithium Battery
SLB48-150-146-5
15S Series, Generation 5

Incell Smart Lithium Battery™ is an advanced power backup


system for telecom use. Its rechargeable lithium-ion battery
provides reliable power backup for hybrid, off-grid and grid-
connected telecom sites worldwide.
Technical Specification
Enclosure Size 19" 4U Safe
Lithium Chemistry LFP All our products are designed with
your safety in mind - thoroughly
Rated Voltage 48 V verified and certified for safe
Capacity Ah 150 Ah
operation.
Energy Wh 7200 Wh Simple
Advanced technology made
Calendar Life @ 80% SOC 15 years
super easy to use. easy to install,
Peak Discharge Power 6kW for 60 seconds maintenance free, charge control.
Discharge Cutoff Current 100 A
Strong
End-of-Discharge Voltage (LVBD) 39 V Works in all conditions and
Charge Cutoff Current 50 A
environments. Extra protection
against dust and moisture for
Charge Current Limitation (CLD)* 50 A prolonged life.
Charge Voltage for 100% SOC 54.75 V
Smart
Charge Voltage for 80% SOC 52 V Automatic balancing, automatic
Operating Temperature Charging 0 to +55°C reconnect, remote monitoring
options and much more.
Operating Temperature Discharging -20 to +60°C
Storage Temperature -20 to +60°C Secure
Our unique, patented Anti-Theft
Weight (Kg) Approx. 74 Kg Device disables function of batteries
Dimensions (mm) W 440 D 577 H 173 if removed from site. It’s prepared for
optional GPS tracker.
Circuit breaker 100 A, BMS Controlled, single pole
IP class IP20 Sustainable
The lifetime is extraordinary long. It’s
Communication Protocols RS485, RJ45 (2) ports, Modbus small, light, maintenance free and can
Safety Standards IEC62619, IEC62368, UN38.3 be remotely controlled.
Software for PC (Incell Studio)
included for full local monitoring and
Management & Monitoring
management. Remote
connection via Modbus

*If the recharge current is 50A or higher, the battery will automatically reduce the charge current to 6-12A temporarily
Datasheet SLB48-150-146-5 Version 2

Incell International AB ; Jan Stenbecks Torg 17, PO Box 1037, SE-164 21, Kista, Sweden ; info@incellint.com
Phone: +46 8 5454 4000 ; www.incellint.com
19" 4U / 150Ah Lithium Battery
SLB48-150-146-5
15S Series, Generation 5

SOC vs Voltage @ RT Technical Drawings

Batt V 3600 W 3000 W 2200 W 1800 W 900 W

48,00 35% 31% 23% 22% 20%


47,00 14% 13% 8% 8% 8%
46,00 6% 6% 4% 4% 4%
45,00 4% 4% 3% 3% 3%
44,00 3% 3% 2% 2% 2%
43,00 2% 2% 1% 1% 1%
42,00 2% 1% 1% 1% 1%
41,00 1% 1% 1% 1% 1%
40,00 0% 0% 0% 0% 0%
39,00 0% 0% 0% 0% 0%

Constant Power Discharge Performance @ RT


Batt V 3600 W 3000 W 2200 W 1800 W 900 W

48,00 1 h 20 min 1 h 45 min 2 h 26 min 2 h 54 min 6 h 20 min

47,50 1 h 32 min 1 h 57 min 2 h 40 min 3 h 13 min 6 h 45 min

47,00 1 h 41 min 2 h 7 min 2 h 55 min 3 h 31 min 7 h 20 min

46,50 1 h 47 min 2 h 14 min 3 h 00 min 3 h 39 min 7 h 25 min

46,00 1 h 49 min 2 h 16 min 3 h 2 min 3 h 41 min 7 h 30 min

45,50 1 h 50 min 2 h 17 min 3 h 3 min 3 h 43 min 7 h 30 min

45,00 1 h 51 min 2 h 18 min 3 h 4 min 3 h 44 min 7 h 35 min

44,50 1 h 52 min 2 h 19 min 3 h 5 min 3 h 45 min 7 h 35 min

44,00 1 h 53 min 2 h 20 min 3 h 6 min 3 h 46 min 7 h 40 min


Optional Mounting Directions
43,50 1 h 53 min 2 h 20 min 3 h 7 min 3 h 47 min 7 h 43 min
of Brackets Shown
43,00 1 h 53 min 2 h 21 min 3 h 8 min 3 h 48 min 7 h 46 min

42,50 1 h 54 min 2 h 21 min 3 h 8 min 3 h 49 min 7 h 48 min

42,00 1 h 54 min 2 h 21 min 3 h 9 min 3 h 49 min 7 h 50 min Mounting Bracket

41,50 1 h 55 min 2 h 22 min 3 h 9 min 3 h 50 min 7 h 52 min

41,00 1 h 55 min 2 h 22 min 3 h 9 min 3 h 50 min 7 h 53 min

40,50 1 h 55 min 2 h 22 min 3 h 10 min 3 h 50 min 7 h 54 min

40,00 1 h 55 min 2 h 23 min 3 h 10 min 3 h 51 min 7 h 55 min

39,50 1 h 56 min 2 h 23 min 3 h 10 min 3 h 51 min 7 h 56 min

39,00 1 h 56 min 2 h 23 min 3 h 10 min 3 h 51 min 7 h 57 min

Standard accessories included with this battery are: (1) communication cable,
(1) pair of mounting brackets, (1) printed specification installation guide, and (1)
CAN Bus/MOD Bus Terminator

Datasheet SLB48-150-146-5 Version 2

Incell International AB ; Jan Stenbecks Torg 17, PO Box 1037, SE-164 21, Kista, Sweden ; info@incellint.com
Phone: +46 8 5454 4000 ; www.incellint.com
19" 4U / 200Ah Lithium Battery
SLB48-200-146-1
13S Series, Generation 5

Incell Smart Lithium Battery™ is an advanced power backup


system for telecom use. Its rechargeable lithium-ion battery
provides reliable power backup for hybrid, off-grid and grid-
connected telecom sites worldwide.
Technical Specification
Enclosure Size 19" 4U Safe
Lithium Chemistry NMC All our products are designed with
your safety in mind - thoroughly
Rated Voltage 48 V verified and certified for safe
Capacity Ah 200 Ah
operation.
Energy Wh 9438 Wh Simple
Advanced technology made
Calendar Life @ 80% SOC 20 years
super easy to use. easy to install,
Peak Discharge Power 6kW for 60 seconds maintenance free, charge control.
Discharge Cutoff Current 100 A
Strong
End-of-Discharge Voltage (LVBD)** 32.5 V Works in all conditions and
Charge Cutoff Current 100 A
environments. Extra protection
against dust and moisture for
Charge Current Limitation (CLD)* 100 A prolonged life.
Charge Voltage for 100% SOC 54.6 V
Smart
Charge Voltage for 80% SOC 52 V Automatic balancing, automatic
Operating Temperature Charging 0 to +55°C reconnect, remote monitoring
options and much more.
Operating Temperature Discharging -20 to +60°C
Storage Temperature -20 to +60°C Secure
Our unique, patented Anti-Theft
Weight (Kg) Approx. 51 Kg Device disables function of batteries
Dimensions (mm) W 440 D 557 H 173 if removed from site. It’s prepared for
optional GPS tracker.
Circuit breaker 100 A, BMS Controlled, single pole
IP class IP20 Sustainable
The lifetime is extraordinary long. It’s
Communication Protocols RS485, RJ45 (2) ports, Modbus small, light, maintenance free and can
Safety Standards IEC62619, IEC62368, UN38.3 be remotely controlled.
Software for PC (Incell Studio)
included for full local monitoring and
Management & Monitoring
management. Remote
connection via Modbus

*If the recharge current is 100A or higher, the battery will automatically reduce the charge current to 6-12A temporarily
** Cut off when one cell reaches 2.5V, 13 cells in series Datasheet SLB48-200-146-1 Version 2

Incell International AB ; Jan Stenbecks Torg 17, PO Box 1037, SE-164 21, Kista, Sweden ; info@incellint.com
Phone: +46 8 5454 4000 ; www.incellint.com
19" 4U / 200Ah Lithium Battery
SLB48-200-146-1
13S Series, Generation 5

Constant Power Discharge Performance @ RT SOC vs Voltage @ RT


Batt V 4600 W 4000 W 3500 W 3100 W 2300 W 1800 W 1100 W 900 W Voltage V
SOC
47,00 1 h 3 min 1 h 15 min 1 h 27 min 1 h 40 min 2 h 19 min 2 h 59 min 4 h 58 min 6 h 17 min 0.2C
(%)
46,50 1 h 7 min 1 h 20 min 1 h 33 min 1 h 48 min 2 h 31 min 3 h 14 min 5 h 24 min 6 h 49 min Discharge

46,00 1 h 12 min 1 h 26 min 1 h 40 min 1 h 57 min 2 h 43 min 3 h 30 min 5 h 47 min 7 h 18 min 100 54.4
90 52.5
45,50 NA 1 h 33 min 1 h 48 min 2 h 6 min 2 h 54 min 3 h 43 min 6 h 6 min 7 h 40 min
80 51.5
45,00 NA 1 h 40 min 1 h 55 min 2 h 14 min 3 h 4 min 3 h 54 min 6 h 21 min 8 h 00 min
70 50.0
44,50 NA 1 h 46 min 2 h 2 min 2 h 21 min 3 h 13 min 4 h 5 min 6 h 39 min 8 h 23 min
60 48.9
44,00 NA 1 h 51 min 2 h 8 min 2 h 28 min 3 h 21 min 4 h 16 min 6 h 56 min 8 h 44 min
50 47.6
43,50 NA 1 h 54 min 2 h 11 min 2 h 32 min 3 h 26 min 4 h 22 min 7 h 2 min 8 h 52 min
40 46.5
43,00 NA 1 h 58 min 2 h 15 min 2 h 36 min 3 h 30 min 4 h 26 min 7 h 9 min 9 h 2 min
30 45.5
42,50 NA 2 h 1 min 2 h 18 min 2 h 39 min 3 h 34 min 4 h 30 min 7 h 16 min 9 h 9 min 20 44.2
42,00 NA 2 h 3 min 2 h 20 min 2 h 41 min 3 h 37 min 4 h 34 min 7 h 21 min 9 h 16 min 10 41.1
41,50 NA 2 h 5 min 2 h 22 min 2 h 43 min 3 h 39 min 4 h 37 min 7 h 26 min 9 h 22 min 0 32.5
41,00 NA 2 h 6 min 2 h 24 min 2 h 45 min 3 h 41 min 4 h 39 min 7 h 31 min 9 h 27 min

40,50 NA 2 h 7 min 2 h 25 min 2 h 46 min 3 h 42 min 4 h 41 min 7 h 34 min 9 h 31 min


Constant Current Discharge
40,00 NA 2 h 8 min 2 h 26 min 2 h 47 min 3 h 44 min 4 h 43 min 7 h 39 min 9 h 37 min Performance @ RT
39,50 NA NA 2 h 27 min 2 h 48 min 3 h 46 min 4 h 45 min 7 h 43 min 9 h 42 min
Capacity
EODV
39,00 NA NA 2 h 28 min 2 h 50 min 3 h 48 min 4 h 48 min 7 h 47 min 9 h 46 min @0.2C (40A)
38,5 NA NA 2 h 29 min 2 h 51 min 3 h 49 min 4 h 50 min 7 h 50 min 9 h 50 min 39.0 V 186.8 Ah
38,00 NA NA 2 h 30 min 2 h 52 min 3 h 50 min 4 h 52 min 7 h 53 min 9 h 54 min 37.7 V 190.6 Ah
37,50 NA NA 2 h 31 min 2 h 53 min 3 h 51 min 4 h 54 min 7 h 55 min 9 h 56 min
36.4 V 193.4 Ah
37,00 NA NA 2 h 32 min 2 h 54 min 3 h 53 min 4 h 55 min 7 h 56 min 9 h 58 min
35.1 V 195.2 Ah
36,50 NA NA 2 h 32 min 2 h 55 min 3 h 54 min 4 h 56 min 7 h 58 min 10 h 0 min

36,00 NA NA 2 h 33 min 2 h 55 min 3 h 55 min 4 h 57 min 8 h 00 min 10 h 2 min 33.8 V 196.4 Ah

35,50 NA NA 2 h 33 min 2 h 56 min 3 h 55 min 4 h 57 min 8 h 1 min 10 h 4 min 32.5 V 197.2 Ah


35,00 NA NA 2 h 33 min 2 h 56 min 3 h 56 min 4 h 58 min 8 h 2 min 10 h 5 min

34,50 NA NA NA 2 h 57 min 3 h 56 min 4 h 58 min 8 h 3 min 10 h 6 min

34,00 NA NA NA 2 h 57 min 3 h 57 min 4 h 59 min 8 h 3 min 10 h 7 min


Standard accessories included with this
33,50 NA NA NA 2 h 57 min 3 h 57 min 4 h 59 min 8 h 4 min 10 h 7 min battery are: (1) communication cable,
33,00 NA NA NA 2 h 57 min 3 h 58 min 5 h 00 min 8 h 4 min 10 h 8 min (1) pair of mounting brackets, (1) printed
specification installation guide, and (1) CAN
32,50 NA NA NA 2 h 57 min 3 h 58 min 5 h 00 min 8 h 4 min 10 h 8 min
Bus/MOD Bus Terminator
Technical Drawings
Mounting Bracket

Optional Mounting Directions


of Brackets Shown
Datasheet SLB48-200-146-1 Version 2

Incell International AB ; Jan Stenbecks Torg 17, PO Box 1037, SE-164 21, Kista, Sweden ; info@incellint.com
Phone: +46 8 5454 4000 ; www.incellint.com
19" 4U / 200Ah Lithium Battery
SLB48-200-146-2
14S Series, Generation 5

Incell Smart Lithium Battery™ is an advanced power backup


system for telecom use. Its rechargeable lithium-ion battery
provides reliable power backup for hybrid, off-grid and grid-
connected telecom sites worldwide.
Technical Specification
Enclosure Size 19" 4U Safe
Lithium Chemistry NMC All our products are designed with
your safety in mind - thoroughly
Rated Voltage 48 V verified and certified for safe
Capacity Ah 200 Ah
operation.
Energy Wh 10164 Wh Simple
Advanced technology made
Calendar Life @ 80% SOC 20 years
super easy to use. easy to install,
Peak Discharge Power 6kW for 60 seconds maintenance free, charge control.
Discharge Cutoff Current 100 A
Strong
End-of-Discharge Voltage (LVBD)** 35 V Works in all conditions and
Charge Cutoff Current 100 A
environments. Extra protection
against dust and moisture for
Charge Current Limitation (CLD)* 100 A prolonged life.
Charge Voltage for 100% SOC 58.8 V
Smart
Charge Voltage for 80% SOC 56 V Automatic balancing, automatic
Operating Temperature Charging 0 to +55°C reconnect, remote monitoring
options and much more.
Operating Temperature Discharging -20 to +60°C
Storage Temperature -20 to +60°C Secure
Our unique, patented Anti-Theft
Weight (Kg) Approx. 54 Kg Device disables function of
Dimensions (mm) W 440 D 557 H 173 batteries if removed from site. It’s
prepared for optional GPS tracker.
Circuit breaker 100 A, BMS Controlled, single pole
IP class IP20 Sustainable
The lifetime is extraordinary long.
Communication Protocols RS485, RJ45 (2) ports, Modbus It’s small, light, maintenance free
Safety Standards IEC62619, IEC62368, UN38.3 and can be remotely controlled.
Software for PC (Incell Studio)
included for full local monitoring and
Management & Monitoring
management. Remote
connection via Modbus

*If the recharge current is 100A or higher, the battery will automatically reduce the charge current to 6-12A temporarily
** Cut off when one cell reaches 2.5V, 14 cells in series Datasheet SLB48-200-146-2 Version 2

Incell International AB ; Jan Stenbecks Torg 17, PO Box 1037, SE-164 21, Kista, Sweden ; info@incellint.com
Phone: +46 8 5454 4000 ; www.incellint.com
19" 4U / 200Ah Lithium Battery
SLB48-200-146-2
14S Series, Generation 5

Constant Power Discharge Performance @ RT SOC vs Voltage @ RT


Batt V 4300 W 3700 W 3300 W 2500 W 2000 W 1200 W 1000 W Voltage V
SOC
49,00 1 h 33 min 1 h 48 min 2 h 6 min 2 h 54 min 3 h 43 min 6 h 6 min 7 h 40 min 0.2C
(%)
48,50 1 h 40 min 1 h 55 min 2 h 14 min 3 h 4 min 3 h 54 min 6 h 21 min 8 h 00 min Discharge

48,00 1 h 44 min 2h 2 h 19 min 3 h 10 min 4 h 2 min 6 h 34 min 8 h 17 min 100 58.5


90 56.6
47,50 1 h 50 min 2 h 6 min 2 h 26 min 3 h 19 min 4 h 13 min 6 h 53 min 8 h 41 min
80 55.4
47,00 1 h 53 min 2 h 10 min 2 h 30 min 3 h 25 min 4 h 20 min 7 h 00 min 8 h 50 min
70 53.9
46,50 1 h 57 min 2 h 14 min 2 h 35 min 3 h 29 min 4 h 25 min 7 h 8 min 8 h 59 min
60 52.6
46,00 1 h 59 min 2 h 17 min 2 h 37 min 3 h 32 min 4 h 28 min 7 h 12 min 9 h 6 min
50 51.2
45,50 2 h 2 min 2 h 19 min 2 h 40 min 3 h 35 min 4 h 32 min 7 h 18 min 9 h 13 min
40 50.1
45,00 2 h 3 min 2 h 21 min 2 h 42 min 3 h 37 min 4 h 35 min 7 h 24 min 9 h 19 min
30 49.0
44,50 2 h 5 min 2 h 22 min 2 h 43 min 3 h 39 min 4 h 37 min 7 h 27 min 9 h 23 min 20 47.6
44,00 2 h 6 min 2 h 24 min 2 h 45 min 3 h 41 min 4 h 40 min 7 h 32 min 9 h 29 min 10 44.2
43,50 2 h 7 min 2 h 25 min 2 h 46 min 3 h 42 min 4 h 42 min 7 h 36 min 9 h 33 min 0 35.0
43,00 2 h 8 min 2 h 26 min 2 h 47 min 3 h 44 min 4 h 44 min 7 h 40 min 9 h 38 min

42,50 NA 2 h 27 min 2 h 48 min 3 h 46 min 4 h 46 min 7 h 43 min 9 h 42 min

42,00 NA 2 h 28 min 2 h 50 min 3 h 47 min 4 h 48 min 7 h 47 min 9 h 46 min

41,50 NA 2 h 29 min 2 h 51 min 3 h 49 min 4 h 50 min 7 h 50 min 9 h 50 min Constant Current Discharge
Performance @ RT
41,00 NA 2 h 30 min 2 h 52 min 3 h 50 min 4 h 51 min 7 h 52 min 9 h 53 min
Capacity
40,50 NA 2 h 31 min 2 h 53 min 3 h 52 min 4 h 53 min 7 h 54 min 9 h 56 min EODV
@0.2C (40A)
40,00 NA 2 h 31 min 2 h 54 min 3 h 52 min 4 h 54 min 7 h 56 min 9 h 58 min
42.0 V 186.8 Ah
39,50 NA 2 h 32 min 2 h 54 min 3 h 53 min 4 h 55 min 7 h 58 min 10 h 00 min
40.6 V 190.6 Ah
39,00 NA 2 h 32 min 2 h 55 min 3 h 54 min 4 h 56 min 7 h 59 min 10 h 1 min
39.2 V 193.4 Ah
38,5 NA 2 h 33 min 2 h 55 min 3 h 55 min 4 h 57 min 8 h 00 min 10 h 3 min

38,00 NA 2 h 33 min 2 h 56 min 3 h 56 min 4 h 58 min 8 h 1 min 10 h 4 min 39.0 V 193.2 Ah

37,50 NA 2 h 34 min 2 h 56 min 3 h 56 min 4 h 58 min 8 h 2 min 10 h 5 min 38.9 V 193.6 Ah


37,00 NA 2 h 34 min 2 h 57 min 3 h 56 min 4 h 59 min 8 h 3 min 10 h 6 min
37.8 V 195.2 Ah
36,50 NA NA 2 h 57 min 3 h 57 min 4 h 59 min 8 h 3 min 10 h 7 min
36.4 V 196.4 Ah
36,00 NA NA 2 h 57 min 3 h 57 min 5 h 00 min 8 h 4 min 10 h 7 min
35.0 V 197.2 Ah
35,50 NA NA 2 h 57 min 3 h 57 min 5 h 00 min 8 h 4 min 10 h 8 min

35,00 NA NA 2 h 57 min 3 h 57 min 5 h 00 min 8 h 4 min 10 h 8 min

Technical Drawings

Mounting Bracket

Standard accessories included with this


battery are: (1) communication cable, (1) pair
of mounting brackets, (1) printed specification
installation guide, and (1) CAN Bus/MOD Bus
Terminator Optional Mounting Directions
of Brackets Shown
Datasheet SLB48-200-146-2 Version 2

Incell International AB ; Jan Stenbecks Torg 17, PO Box 1037, SE-164 21, Kista, Sweden ; info@incellint.com
Phone: +46 8 5454 4000 ; www.incellint.com
19" 4U / 250Ah Lithium Battery
SLB48-250-146-1
13S Series, Generation 5

Incell Smart Lithium Battery™ is an advanced power backup


system for telecom use. Its rechargeable lithium-ion battery
provides reliable power backup for hybrid, off-grid and grid-
connected telecom sites worldwide.
Technical Specification
Enclosure Size 19" 4U Safe
Lithium Chemistry NMC All our products are designed with
your safety in mind - thoroughly
Rated Voltage 48 V verified and certified for safe
Capacity Ah 250 Ah
operation.
Energy Wh 12033 Wh Simple
Advanced technology made
Calendar Life @ 80% SOC 20 years
super easy to use. easy to install,
Peak Discharge Power 6kW for 60 seconds maintenance free, charge control.
Discharge Cutoff Current 100 A
Strong
End-of-Discharge Voltage (LVBD)** 32.5 V Works in all conditions and
Charge Cutoff Current 100 A
environments. Extra protection
against dust and moisture for
Charge Current Limitation (CLD)* 100 A prolonged life.
Charge Voltage for 100% SOC 54.6 V
Smart
Charge Voltage for 80% SOC 52 V Automatic balancing, automatic
Operating Temperature Charging 0 to +55°C reconnect, remote monitoring
options and much more.
Operating Temperature Discharging -20 to +60°C
Storage Temperature -20 to +60°C Secure
Our unique, patented Anti-Theft
Weight (Kg) Approx. 63 Kg Device disables function of batteries
Dimensions (mm) W 440 D 557 H 173 if removed from site. It’s prepared for
optional GPS tracker.
Circuit breaker 100 A, BMS Controlled, single pole
IP class IP20 Sustainable
The lifetime is extraordinary long. It’s
Communication Protocols RS485, RJ45 (2) ports, Modbus small, light, maintenance free and can
Safety Standards IEC62619, IEC62368, UN38.3 be remotely controlled.
Software for PC (Incell Studio)
included for full local monitoring and
Management & Monitoring
management. Remote
connection via Modbus

*If the recharge current is 100A or higher, the battery will automatically reduce the charge current to 6-12A temporarily
** Cut off when one cell reaches 2.5V, 13 cells in series Datasheet SLB48-250-146-1 Version 2

Incell International AB ; Jan Stenbecks Torg 17, PO Box 1037, SE-164 21, Kista, Sweden ; info@incellint.com
Phone: +46 8 5454 4000 ; www.incellint.com
19" 4U / 250Ah Lithium Battery
SLB48-250-146-1
13S Series, Generation 5

Constant Power Discharge Performance @ RT SOC vs Voltage @ RT


Batt V 4400 W 3900 W 2900 W 2300 W 1400 W 1100 W Voltage V
SOC
47,00 1 h 27 min 1 h 41 min 2 h 19 min 2 h 59 min 4 h 58 min 6 h 17 min 0.2C
(%)
46,50 1 h 33 min 1 h 48 min 2 h 31 min 3 h 14 min 5 h 24 min 6 h 49 min Discharge

46,00 1 h 41 min 1 h 57 min 2 h 43 min 3 h 30 min 5 h 47 min 7 h 18 min 100 54.4


90 52.5
45,50 1 h 48 min 2 h 6 min 2 h 54 min 3 h 43 min 6 h 6 min 7 h 40 min
80 51.5
45,00 1 h 55 min 2 h 14 min 3 h 4 min 3 h 54 min 6 h 21 min 8 h 0 min
70 50.0
44,50 2 h 2 min 2 h 21 min 3 h 13 min 4 h 5 min 6 h 39 min 8 h 23 min
60 48.9
44,00 2 h 3 min 2 h 28 min 3 h 21 min 4 h 16 min 6 h 56 min 8 h 44 min
50 47.6
43,50 NA 2 h 32 min 3 h 26 min 4 h 22 min 7 h 2 min 8 h 52 min
40 46.5
43,00 NA 3 h 36 min 3 h 30 min 4 h 26 min 7 h 9 min 9 h 2 min
30 45.5
42,50 NA 2 h 39 min 3 h 34 min 4 h 30 min 7 h 16 min 9 h 9 min 20 44.2
42,00 NA 2 h 41 min 3 h 37 min 4 h 34 min 7 h 21 min 9 h 16 min 10 41.1
41,50 NA 2 h 43 min 3 h 39 min 4 h 37 min 7 h 26 min 9 h 22 min 0 32.5
41,00 NA 2 h 45 min 3 h 41 min 4 h 39 min 7 h 31 min 9 h 27 min

40,50 NA 2 h 46 min 3 h 42 min 4 h 41 min 7 h 34 min 9 h 31 min


Constant Current Discharge
40,00 NA 2 h 47 min 3 h 44 min 4 h 43 min 7 h 39 min 9 h 37 min Performance @ RT
39,50 NA 2 h 48 min 3 h 46 min 4 h 46 min 7 h 43 min 9 h 42 min
Capacity
EODV
39,00 NA 2 h 49 min 3 h 47 min 4 h 48 min 7 h 47 min 9 h 46 min @0.2C (50A)
38,5 NA NA 3 h 49 min 4 h 50 min 7 h 50 min 9 h 50 min 39.0 V 238.2 Ah
38,00 NA NA 3 h 51 min 4 h 52 min 7 h 53 min 9 h 54 min 37.7 V 243.0 Ah
37,50 NA NA 3 h 52 min 4 h 53 min 7 h 55 min 9 h 56 min
36.4 V 246.6 Ah
37,00 NA NA 3 h 53 min 4 h 54 min 7 h 57 min 9 h 58 min
35.1 V 248.8 Ah
36,50 NA NA 3 h 54 min 4 h 56 min 7 h 58 min 10 h 0 min

36,00 NA NA 3 h 55 min 4 h 57 min 8 h 0 min 10 h 2 min 33.8 V 250.4 Ah

35,50 NA NA 3 h 55 min 4 h 57 min 8 h 1 min 10 h 4 min 32.5 V 251.4 Ah


35,00 NA NA 3 h 56 min 4 h 58 min 8 h 2 min 10 h 5 min

34,50 NA NA 3 h 57 min 4 h 59 min 8 h 3 min 10 h 6 min

34,00 NA NA 3 h 57 min 4 h 59 min 8 h 3 min 10 h 7 min

33,50 NA NA 3 h 57 min 4 h 59 min 8 h 4 min 10 h 7 min Standard accessories included with this battery
33,00 NA NA 3 h 57 min 5 h 0 min 8 h 5 min 10 h 8 min
are: (1) communication cable, (1) pair of mounting
brackets, (1) printed specification installation
32,50 NA NA 3 h 57 min 5 h 0 min 8 h 5 min 10 h 8 min
guide, and (1) CAN Bus/MOD Bus Terminator
Technical Drawings

Mounting Bracket

Optional Mounting Directions


of Brackets Shown
Datasheet SLB48-250-146-1 Version 2

Incell International AB ; Jan Stenbecks Torg 17, PO Box 1037, SE-164 21, Kista, Sweden ; info@incellint.com
Phone: +46 8 5454 4000 ; www.incellint.com

You might also like